Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

ALMA OBSERVATIONS OF HD 141569’s CIRCUMSTELLAR DISK

We present ALMA band 7 (345 GHz) continuum and {sup 12}CO( J = 3-2) observations of the circumstellar disk surrounding HD 141569. At an age of about 5 Myr, the disk has a complex morphology that may be best interpreted as a nascent debris system with gas. Our 870 μ m ALMA continuum observations resolve a dust disk out to approximately 56 au from the star (assuming a distance of 116 pc) with 0.″38 resolution and 0.07 mJy beam{sup −1} sensitivity. We measure a continuum flux density for this inner material of 3.8 ± 0.4 mJy (including calibration uncertainties). The {sup 12}CO(3-2) gas is resolved kinematically and spatially from about 30 to 210 au. The integrated {sup 12}CO(3-2) line flux density is 15.7 ± 1.6 Jy km s{sup −1}. We estimate the mass of the millimeter debris and {sup 12}CO(3-2) gas to be ≳0.04 M {sub ⊕} and ∼2 × 10{sup −3} M {sub ⊕}, respectively. If the millimeter grains are part of a collisional cascade, then we infer that the inner disk (<50 au) has ∼160 M {sub ⊕} contained within objects less than 50 km in radius, depending on the planetesimal size distribution and density assumptions. Markov Chain Monte Carlo modeling of the system reveals a disk morphology with an inclination of 53.°4 centered around an M = 2.39 M {sub ⊙} host star ( M sin( i ) = 1.92 M {sub ⊙}). We discuss whether the gas in HD 141569's disk may be second generation. If it is, the system can be used to study the clearing stages of planet formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Commercialization of laser-induced breakdown spectroscopy for lead-in-paint inspection

A study was undertaken to determine if laser-induced breakdown spectroscopy (LIBS) can be a practical and competitive alternative to x-ray fluorescence (XRF) methods for lead-in-paint inspection. Experiments in the laboratory confirmed that LIBS is suitable for detecting lead in paint at the hazard levels defined by federal agencies. Although we compared speed, function, and cost, fundamental differences between the XRF and LIBS measurements limited our ability to make a quantitative performance comparison. While the LIBS method can achieve the required sensitivity and offers a way to obtain unique information during inspection, the current component costs will likely restrict interest in the method to niche applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New method for fitting coefficients in standard model effective theory

We present an alternative method for carrying out a principal-component analysis of Wilson coefficients in standard model effective field theory (SMEFT). The method is based on singular-value decomposition (SVD). The SVD method provides information about the sensitivity of experimental observables to physics beyond the standard model that is not accessible in the Fisher-information method. In principle, the SVD method can also have computational advantages over diagonalization of the Fisher information matrix. We demonstrate the SVD method by applying it to the dimension-6 coefficients for the process of top-quark decay to a b quark and a W boson and use this example to illustrate some pitfalls in widely used fitting procedures. We also outline an iterative procedure for applying the SVD method to dimension-8 SMEFT coefficients.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of piezoelectric foil for flow diagnostics

A laboratory investigation was conducted to characterize two piezoelectric-film sensor configurations, a rigidly mounted sensor and a sensor mounted over an air cavity. The sensors are evaluated for sensitivity and frequency response, and methods to optimize data are presented. The cavity-mounted sensor exhibited a superior frequency response and was more sensitive to normal pressure fluctuations and less sensitive to vibrations through the structure. Both configurations were sensitive to large-scale structural vibrations. Flight-test data are shown for cavity-mounted sensors, illustrating practical aspects to consider when designing sensors for application in such harsh environments. The relation of the data to skin friction and maximum shear stress, transition detection, and turbulent viscous layers is derived through analysis of the flight data.

Carraway, Debra L.↗

SU-D-213-06: Dosimetry of Modulated Electron Radiation Therapy Using Fricke Gel Dosimeter

Purpose: Modulated electron radiation therapy (MERT) has been proposed as an effective modality for treatment of superficial targets. MERT utilizes multiple beams of different energies which are intensity modulated to deliver optimized dose distribution. Energy independent dosimeters are thus needed for quantitative evaluations of MERT dose distributions and measurements of absolute doses delivered to patients. Thus in the current work we study the feasibility of Fricke gel dosimeters in MERT dosimetry. Methods: Batches of radiation sensitive Fricke gel is fabricated and poured into polymethyl methacrylate cuvettes. The samples were irradiated in solid water phantom and a thick layer of bolus was used as a buildup. A spectrophotometer system was used for measuring the color changes (the absorbance) before and after irradiation and then we calculate net absorbance. We constructed calibration curves to relate the measured absorbance in terms of absorbed dose for all available electron energies. Dosimetric measurements were performed for mixed electron beam delivery and we also performed measurement for segmented field delivery with the dosimeter placed at the junction of two adjacent electron beams of different energies. Dose measured by our gel dosimetry is compared to that calculation from our precise treatment planning system. We also initiated a Monte Carlo study to evaluate the water equivalence of our dosimeters. MCBEAM and MCSIM codes were used for treatment head simulation and phantom dose calculation. PDDs and profiles were calculated for electron beams incident on a phantom designed with 1cm slab of Fricke gel. Results: The calibration curves showed no observed energy dependence with all studied electron beam energies. Good agreement was obtained between dose calculated and that obtained by gel dosimetry. Monte Carlo results illustrated the tissue equivalency of our Gel dosimeters. Conclusion: Fricke Gel dosimeters represent a good option for the dosimetric quality assurance prior to MERT application.

60 APPLIED LIFE SCIENCES↗

A Comparative Study of the Hypoxia PET Tracers [{sup 18}F]HX4, [{sup 18}F]FAZA, and [{sup 18}F]FMISO in a Preclinical Tumor Model

Purpose: Several individual clinical and preclinical studies have shown the possibility of evaluating tumor hypoxia by using noninvasive positron emission tomography (PET). The current study compared 3 hypoxia PET tracers frequently used in the clinic, [{sup 18}F]FMISO, [{sup 18}F]FAZA, and [{sup 18}F]HX4, in a preclinical tumor model. Tracer uptake was evaluated for the optimal time point for imaging, tumor-to-blood ratios (TBR), spatial reproducibility, and sensitivity to oxygen modification. Methods and Materials: PET/computed tomography (CT) images of rhabdomyosarcoma R1-bearing WAG/Rij rats were acquired at multiple time points post injection (p.i.) with one of the hypoxia tracers. TBR values were calculated, and reproducibility was investigated by voxel-to-voxel analysis, represented as correlation coefficients (R) or Dice similarity coefficient of the high-uptake volume. Tumor oxygen modifications were induced by exposure to either carbogen/nicotinamide treatment or 7% oxygen breathing. Results: TBR was stabilized and maximal at 2 hours p.i. for [{sup 18}F]FAZA (4.0 ± 0.5) and at 3 hours p.i. for [{sup 18}F]HX4 (7.2 ± 0.7), whereas [{sup 18}F]FMISO showed a constant increasing TBR (9.0 ± 0.8 at 6 hours p.i.). High spatial reproducibility was observed by voxel-to-voxel comparisons and Dice similarity coefficient calculations on the 30% highest uptake volume for both [{sup 18}F]FMISO (R = 0.86; Dice coefficient = 0.76) and [{sup 18}F]HX4 (R = 0.76; Dice coefficient = 0.70), whereas [{sup 18}F]FAZA was less reproducible (R = 0.52; Dice coefficient = 0.49). Modifying the hypoxic fraction resulted in enhanced mean standardized uptake values for both [{sup 18}F]HX4 and [{sup 18}F]FAZA upon 7% oxygen breathing. Only [{sup 18}F]FMISO uptake was found to be reversible upon exposure to nicotinamide and carbogen. Conclusions: This study indicates that each tracer has its own strengths and, depending on the question to be answered, a different tracer can be put forward.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance characteristics of dedicated molecular breast imaging systems at low doses

Purpose: The purpose of this study was to compare the system performance characteristics and lesion detection capability of two molecular breast imaging (MBI) systems: a multicrystal sodium iodide (NaI)-based single-head system and a cadmium zinc telluride (CZT)-based dual-head system at low administered doses (150–300 MBq) of Tc-99m sestamibi. Methods: System performance characteristics including count sensitivity, uniformity, energy resolution, and spatial resolution were measured using standard NEMA methods, or a modified version thereof in cases where the standard NEMA protocol could not be applied. A contrast-detail phantom with 48 lesions at varying depths from the collimator surface was used to assess lesion contrast-to-noise-ratio (CNR) using background count densities comparable to those observed in patient studies performed with administered doses of 150 MBq Tc-99m sestamibi. Lesions with CNR >3 were deemed to be detectable. Thirty patients undergoing MBI examinations with administered doses of 150–300 MBq were scanned for an additional view on the pixelated NaI system. CNR was calculated for lesions observed on patient images. Background count densities of patient images were measured and compared between the two systems. Results: Over the central field of view, integral and differential uniformity were 6.1% and 4.2%, respectively, for the pixelated NaI system, and 3.8% and 2.7%, respectively, for the CZT system. Count sensitivity was 10.8 kcts/min/MBq for the NaI system and 32.9 kcts/min/MBq for the CZT system. Energy resolution was 13.5% on the pixelated NaI system and 4.5% on the CZT system. Spatial resolution (full-width at half-maximum) for the pixelated NaI detector was 4.2 mm at a distance of 1.2 cm from the collimator and 5.2 mm at 3.1 cm. Spatial resolution of a single CZT detector was 2.9 mm at a distance of 1.2 cm from the collimator and 4.7 mm at 3.1 cm. Effective spatial resolution obtained with dual-head CZT was below 4.7 mm throughout a simulated breast thickness of 6 cm. From contrast-detail phantom images of lesions at distances of 1.5–4.5 cm from the collimator face, the CZT system detected 124 of 144 (86%) of lesions compared to 97 of 144 (67%) with the NaI system. In patient studies, from comparison of the same view with both systems, a total of 7 breast lesions were identified on CZT system in seven patients, and 4 of 7 (57%) were detected on NaI system. Patient image background count densities on the CZT system were on average 3.4 times higher than those on the NaI system. Conclusions: The CZT system demonstrated better uniformity, count sensitivity, spatial resolution, energy resolution, and lesion detection in phantom and patient studies compared to the NaI system. At administered doses of 150–300 MBq Tc-99m sestamibi, patient results obtained with CZT systems may not be directly translatable to NaI systems.

60 APPLIED LIFE SCIENCES↗

Discrete analysis of spatial-sensitivity models

Procedures for reducing the computational burden of current models of spatial vision are described, the simplifications being consistent with the prediction of the complete model. A method for using pattern-sensitivity measurements to estimate the initial linear transformation is also proposed which is based on the assumption that detection performance is monotonic with the vector length of the sensor responses. It is shown how contrast-threshold data can be used to estimate the linear transformation needed to characterize threshold performance.

Nielsen, Kenneth R. K.↗

The Surface-Tension Method of Visually Inspecting Honeycomb-Core Sandwich Plates

When one face of a metal-honeycomb-core sandwich plate is heated or cooled relative to the other, heat transfer through the core causes the temperature on each face at the lines of contact with the core to be slightly different from that on the rest of the face. If a thin liquid film is applied to the face, the variation of surface tension with temperature causes the liquid to move from warmer to cooler areas and thus to develop a pattern corresponding to the temperature pattern on the face. Irregularities in the pattern identify the locations where the core is not adequately bonded to the face sheet. The pattern is easily observed when a fluorescent liquid is used and illumination is by means of ultraviolet light. Observation in ordinary light is also possible when a very deeply colored liquid is used. A method based on the use of a thermographic phosphor to observe the temperature pattern was found to be less sensitive than the surface-tension method. A sublimation method was found to be not only less sensitive but also far more troublesome.

Katzoff, Samuel↗

Improvement of the prediction of surface ozone concentration over conterminous U.S. by a computationally efficient second-order Rosenbrock solver in CAM4-Chem

The global chemistry-climate model (CAM4-Chem) overestimates the surface ozone concentration over the conterminous U.S. (CONUS). Reasons for this positive bias include emission, meteorology, chemical mechanism, and solver. In this study, we explore the last possibility by examining the sensitivity to the numerical methods for solving the chemistry equations. A second-order Rosenbrock (ROS-2) solver is implemented in CAM4-Chem to examine its influence on the surface ozone concentration and the computational performance of the chemistry program. Results show that under the same time step size (1800 s), statistically significant reduction of positive bias is achieved by the ROS-2 solver. The improvement is as large as 5.2 ppb in Eastern U.S. during summer season. The ROS-2 solver is shown to reduce the positive bias in Europe and Asia as well, indicating the lower surface ozone concentration over the CONUS predicted by the ROS-2 solver is not a trade-off consequence with increasing the ozone concentration at other global regions. In addition, by refining the time step size to 180 s, the first-order implicit solver does not provide statistically significant improvement of surface ozone concentration. It reveals that the better prediction from the ROS-2 solver is not only due to its accuracy but also due to its suitability for stiff chemistry equations. As an added benefit, the computation cost of the ROS-2 solver is almost half of first-order implicit solver. The improved computational efficiency of the ROS-2 solver is due to the reuse of the Jacobian matrix and lower upper (LU) factorization during its multistage calculation.

54 ENVIRONMENTAL SCIENCES↗

Pore network modeling of the electrical signature of solute transport in dual-domain media: Dual-Domain Electrical Signature

Dual-domain models are used to explain anomalous solute transport behavior observed in diverse hydrologic settings and applications, from groundwater remediation to hyporheic exchange. To constrain such models, new methods are needed with sensitivity to both immobile and mobile domains. Recent experiments indicate that dual-domain transport of ionic tracers has an observable geoelectrical signature, appearing as a nonlinear, hysteretic relation between paired bulk and fluid electrical conductivity. Here in this paper we present a mechanistic explanation for this geoelectrical signature and evaluate assumptions underlying a previously published petrophysical model for bulk conductivity in dual-domain media. Pore network modeling of fluid flow, solute transport, and electrical conduction (1) verifies the geoelectrical signature of dual-domain transport, (2) reveals limitations of the previously used petrophysical model, and (3) demonstrates that a new petrophysical model, based on differential effective media theory, closely approximates the simulated bulk/fluid conductivity relation. These findings underscore the potential of geophysically based calibration of dual-domain models.

58 GEOSCIENCES↗

Regioselective Generation of Single‐Site Iridium Atoms and Their Evolution into Stabilized Subnanometric Iridium Clusters in MWW Zeolite

Abstract Preparation of supported metal catalysts with uniform particle size and coordination environment is a challenging and important topic in materials chemistry and catalysis. In this work, we report the regioselective generation of single‐site Ir atoms and their evolution into stabilized subnanometric Ir clusters in MWW zeolite, which are located at the 10MR window connecting the two neighboring 12MR supercages. The size of the subnanometric Ir clusters can be controlled by the post‐synthesis treatments and maintain below 1 nm even after being reduced at 650 °C, which cannot be readily achieved with samples prepared by conventional impregnation methods. The high structure sensitivity, size‐dependence, of catalytic performance in the alkane hydrogenolysis reaction of Ir clusters in the subnanometric regime is evidenced.

Liu, Lichen↗

Regioselective Generation of Single‐Site Iridium Atoms and Their Evolution into Stabilized Subnanometric Iridium Clusters in MWW Zeolite

Abstract Preparation of supported metal catalysts with uniform particle size and coordination environment is a challenging and important topic in materials chemistry and catalysis. In this work, we report the regioselective generation of single‐site Ir atoms and their evolution into stabilized subnanometric Ir clusters in MWW zeolite, which are located at the 10MR window connecting the two neighboring 12MR supercages. The size of the subnanometric Ir clusters can be controlled by the post‐synthesis treatments and maintain below 1 nm even after being reduced at 650 °C, which cannot be readily achieved with samples prepared by conventional impregnation methods. The high structure sensitivity, size‐dependence, of catalytic performance in the alkane hydrogenolysis reaction of Ir clusters in the subnanometric regime is evidenced.

Liu, Lichen↗

Segment 2/3 Hypertrophy is Greater When Right Portal Vein Embolisation is Extended to Segment 4 in Patients with Colorectal Liver Metastases: A Retrospective Cohort Study

Background: In patients with colorectal cancer liver metastases (CRLM), right portal vein embolisation (RPVE) is used to increase the volume of the future remnant liver (FRL) before major hepatic resection. It is not established whether embolisation of segment 4 in addition RPVE (RPVE + 4) induces greater hypertrophy of the FRL. Limitations of prior studies include heterogenous populations and use of hypertrophy metrics sensitive to baseline variables. Methods: From 2010 to 2015, consecutive patients undergoing RPVE or RPVE + 4 for CRLM, who had not undergone prior major hepatic resection and in whom imaging was available, were included in a retrospective study. Data were extracted from hospital electronic records. Volumetric assessments of segments 2–3 were made on cross-sectional imaging before and after embolisation and corrected for standardised liver volume. Results: Ninety-nine patients underwent PVE, and 60 met the inclusion criteria. Thirty-eight patients underwent RPVE, and 22 underwent RPVE + 4. Forty-five patients had undergone median 6 cycles of prior chemotherapy. Eighteen patients had FRL metastases at PVE, and 16 had undergone subsegmental metastasectomy in the FRL. Assessments of the degree of hypertrophy (DH) of segments 2/3 were made at median 35 (interquartile range 30–49) days after PVE. RPVE + 4 resulted in a significantly greater increase in DH than RPVE (7.7 ± 1.8% vs 11.3 ± 2.6%, p = 0.011). No confounding association between baseline variables and the decision to undertake RPVE or RPVE + 4 was identified. Median survival was 2.4 years and was not influenced by segment 4 embolisation. Conclusion: RPVE + 4 results in greater DH of segments 2/3 than RPVE in people with CLRM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Sampling of Large Deviations

We introduce and test an algorithm that adaptively estimates large deviation functions characterizing the fluctuations of additive functionals of Markov processes in the long-time limit. These functions play an important role for predicting the probability and pathways of rare events in stochastic processes, as well as for understanding the physics of nonequilibrium systems driven in steady states by external forces and reservoirs. The algorithm uses methods from risk-sensitive and feedback control to estimate from a single trajectory a new process, called the driven process, known to be efficient for importance sampling. Its advantages compared to other simulation techniques, such as splitting or cloning, are discussed and illustrated with simple equilibrium and nonequilibrium diffusion models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Construction of a Shallow Underground Low-background Detector for a CTBT Radionuclide Laboratory

The International Monitoring System (IMS) is a verification component of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), and in addition to a series of radionuclide monitoring stations, contains sixteen radionuclide laboratories capable of verification of radionuclide station measurements. This paper presents an overview of a new commercially obtained low-background detector system for radionuclide aerosol measurements recently installed in a shallow (>30 meters water equivalent) underground clean-room facility at Pacific Northwest National Laboratory. Specifics such as low-background shielding materials, active shielding methods, and improvements in sensitivity to IMS isotopes will be covered.

Forrester, Joel B.↗

Sequential chemical separations and multiple ion counting ICP-MS for 241 Pu– 241 Am– 237 Np dating of environmental collections on a single aliquot

In this study, we have developed a combined sequential chemical separation procedure and multiple ion counting ICP-MS measurement method for isotopic measurements of Am in environmental samples. This, in conjunction with established resin bead TIMS measurements for Pu and Np, allows us to measure long-lived Pu–Np–Am nuclides in environmental samples on a single solution aliquot. This single aliquot method reduces time lines and maximizes sample utility for the measurements, improving sensitivity, precision, and accuracy over prior methods. Finally, we have evaluated this new method with environmental reference materials and have obtained accurate results on samples with > 3E6 atoms 241 Am.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Impact of lowering potassium contamination in liquid scintillation cocktails for ultra-sensitive radiation detection

Intrinsic 40 K radioactive backgrounds from impurities of natural K in liquid scintillation cocktails have previously been demonstrated to limit their use in ultra-sensitive applications. Here, this work explores two methodologies in parallel for the reduction of 40 K backgrounds in the cocktails, and lays the groundwork for use in ultra-sensitive applications. In one method, alternative low-K liquid scintillation matrix constituents were identified and in the other, a simple purification method for single components and finished cocktails was developed. Both methods were verified via ICP-MS analysis. Liquid scintillation counting of selected purified cocktails demonstrated background reduction, improved stability, and enhanced performance. The best performing purified cocktail was also counted on a custom-built ultra-low background liquid scintillation counter, with results below the detector background.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗