Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alternative data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Future Directions and Challenges in Shell Stability Analysis

An answer is sought to the question of today, in 1997, after so many years of concentrated research effort in designing buckling critical thin walled shells, why one cannot do any better than using the rather conservative Lower Bound Design Philosophy of the sixties. It will be shown that with the establishment of Initial Imperfection Data Banks and the introduction of Probabilistic Design Procedures one has a viable alternative, that when used judiciously, may lead to improved shell design recommendations.

Arbocz, Johann↗

Experimental Validation of a Closed Brayton Cycle System Transient Simulation

The Brayton Power Conversion Unit (BPCU) is a closed cycle system with an inert gas working fluid. It is located in Vacuum Facility 6 at NASA Glenn Research Center. Was used in previous solar dynamic technology efforts (SDGTD). Modified to its present configuration by replacing the solar receiver with an electrical resistance heater. The first closed-Brayton-cycle to be coupled with an ion propulsion system. Used to examine mechanical dynamic characteristics and responses. The focus of this work was the validation of a computer model of the BPCU. Model was built using the Closed Cycle System Simulation (CCSS) design and analysis tool. Test conditions were then duplicated in CCSS. Various steady-state points. Transients involving changes in shaft rotational speed and heat input. Testing to date has shown that the BPCU is able to generate meaningful, repeatable data that can be used for computer model validation. Results generated by CCSS demonstrated that the model sufficiently reproduced the thermal transients exhibited by the BPCU system. CCSS was also used to match BPCU steady-state operating points. Cycle temperatures were within 4.1% of the data (most were within 1%). Cycle pressures were all within 3.2%. Error in alternator power (as much as 13.5%) was attributed to uncertainties in the compressor and turbine maps and alternator and bearing loss models. The acquired understanding of the BPCU behavior gives useful insight for improvements to be made to the CCSS model as well as ideas for future testing and possible system modifications.

Johnson, Paul K.↗

Poultry Industry Energy Research

The poultry industry, a multi-billion dollar business in the United States, uses great amounts of energy in such operations as broiler growing, feed manufacturing, poultry processing and packing. Higher costs and limited supply of fuels common to the industry are predicted, so poultry producers are seeking ways to reduce energy expenditure. NASA is providing assistance to Delmarva Poultry Industry, Inc., an association of some 4,000 growers and suppliers in one of the nation's largest poultry production areas. Delmarva is the East Coast peninsula that includes Delaware and parts of Maryland and Virginia. The upper right photo shows a weather station in the Delmarva area (wind indicator on the pole, other instruments in the elevated box). The station is located at the University of Maryland's Broiler Sub-station, Salisbury; Maryland, where the university conducts research on poultry production and processing. The sub-station is investigating ways of conserving energy in broiler production and also exploring the potential of solar collectors as an alternative energy source. For these studies, it is essential that researchers have continuous data on temperature, pressure, wind speed and direction, solar intensity and cloud cover. Equipment to acquire such data was loaned and installed by NASA's Wallops Flight Center, Wallops Island, Virginia.

Source record↗

On the Development of Parameterized Linear Analytical Longitudinal Airship Models

In order to explore Titan, a moon of Saturn, airships must be able to traverse the atmosphere autonomously. To achieve this, an accurate model and accurate control of the vehicle must be developed so that it is understood how the airship will react to specific sets of control inputs. This paper explains how longitudinal aircraft stability derivatives can be used with airship parameters to create a linear model of the airship solely by combining geometric and aerodynamic airship data. This method does not require system identification of the vehicle. All of the required data can be derived from computational fluid dynamics and wind tunnel testing. This alternate method of developing dynamic airship models will reduce time and cost. Results are compared to other stable airship dynamic models to validate the methods. Future work will address a lateral airship model using the same methods.

aerobot↗

Using a Support Vector Machine and a Land Surface Model to Estimate Large-Scale Passive Microwave Temperatures over Snow-Covered Land in North America

A support vector machine (SVM), a machine learning technique developed from statistical learning theory, is employed for the purpose of estimating passive microwave (PMW) brightness temperatures over snow-covered land in North America as observed by the Advanced Microwave Scanning Radiometer (AMSR-E) satellite sensor. The capability of the trained SVM is compared relative to the artificial neural network (ANN) estimates originally presented in [14]. The results suggest the SVM outperforms the ANN at 10.65 GHz, 18.7 GHz, and 36.5 GHz for both vertically and horizontally-polarized PMW radiation. When compared against daily AMSR-E measurements not used during the training procedure and subsequently averaged across the North American domain over the 9-year study period, the root mean squared error in the SVM output is 8 K or less while the anomaly correlation coefficient is 0.7 or greater. When compared relative to the results from the ANN at any of the six frequency and polarization combinations tested, the root mean squared error was reduced by more than 18 percent while the anomaly correlation coefficient was increased by more than 52 percent. Further, the temporal and spatial variability in the modeled brightness temperatures via the SVM more closely agrees with that found in the original AMSR-E measurements. These findings suggest the SVM is a superior alternative to the ANN for eventual use as a measurement operator within a data assimilation framework.

Modeling↗

Assessing the Amazon Cloud Suitability for CLARREO's Computational Needs

In this document we compare the performance of the Amazon Web Services (AWS), also known as Amazon Cloud, with the CLARREO (Climate Absolute Radiance and Refractivity Observatory) cluster and assess its suitability for computational needs of the CLARREO mission. A benchmark executable to process one month and one year of PARASOL (Polarization and Anistropy of Reflectances for Atmospheric Sciences coupled with Observations from a Lidar) data was used. With the optimal AWS configuration, adequate data-processing times, comparable to the CLARREO cluster, were found. The assessment of alternatives to the CLARREO cluster continues and several options, such as a NASA-based cluster, are being considered.

Goldin, Daniel↗

GNSS-RO Deep Refraction Signals from Moist Marine Atmospheric Boundary Layer (MABL)

The marine atmospheric boundary layer (MABL) has a profound impact on sensible heat and moisture exchanges between the surface and the free troposphere. The goal of this study is to develop an alternative technique for retrieving MABL-specific humidity (q) using GNSS-RO data in deep-refracted signals. The GNSS-RO signal amplitude (i.e., signal-to-noise ratio or SNR) at the deep straight-line height (H(SL)) was been found to be strongly impacted by water vapor within the MABL. This study presents a statistical analysis to empirically relate the normalized SNR (S(RO)) at deep HSL to the MABL q at 950 hPa (~400 m). When compared to the ERA5 reanalysis data, a good linear q–S(RO) relationship is found with the deep H(SL) S(RO) data, but careful treatments of receiver noise, SNR normalization, and receiver orbital altitude are required. We attribute the good q–S(RO) correlation to the strong refraction from a uniform, horizontally stratiform and dynamically quiet MABL water vapor layer. Ducting and diffraction/interference by this layer help to enhance the S(RO) amplitude at deep H(SL). Potential MABL water vapor retrieval can be further developed to take advantage of a higher number of S(RO) measurements in the MABL compared to the Level-2 products. A better sampled diurnal variation of the MABL q is demonstrated with the S(RO) data over the Southeast Pacific (SEP) and the Northeast Pacific (NEP) regions, which appear to be consistent with the low cloud amount variations reported in previous studies.

diurnal variation↗

Unleashing the Power of Anaerobic–Phototrophic Membrane Bioreactors for Sustainable Bioregenerative Life Support

Using the core ideals of bioregenerative life support, an anaerobic–phototrophic membrane bioreactor (APMBR) has been designed and operated at NASA’s Kennedy Space Center to treat complex wastewaters with the goal of closing water and nutrient cycles on early planetary bases. The system combined the previously operated anaerobic membrane bioreactor and the phototrophic membrane bioreactor that have been detailed in presentations at previous ICES conferences. This newly combined system is able to treat complex wastewater with completely automated controls on a small footprint. The treatment of wastes in this APMBR is as follows: (1) the waste enters the anaerobic subsystem, where solids are hydrolyzed and carbon is removed via anaerobic digestion, (2) an ultrafiltration membrane is used to separate the solids and the recovered water, (3) the effluent from the anaerobic subsystem is fed to the phototrophic subsystem on command, (4) the algae–bacteria consortium aids in nitrification in the recovered water, and (5) an ultrafiltration membrane is used to separate the algae and the final recovered water. The recovered water from the APMBR is rich in nutrients, making it a sustainable source of fertilizer for downstream hydroponic systems. This conference paper will detail the design and operation of the APMBR as a bioregenerative alternative to physical–chemical systems or bag and storage systems. In this paper, data will be presented on subsystem water quality, membrane performance, and effluent quality. Overall, the APMBR has the ability to treat wastewater using a combination of biological and filtration technologies that allow for higher removal efficiencies, low consumable use, and small footprint.

Jason A. Fischer↗

Label Assist: Personalized Travel Models for Longitudinal Data Collection

Understanding travel behavior is crucial to transportation decarbonization. OpenPATH is an open-source mobility platform which collects and analyzes human travel behavior at the individual level. The mobile application passively senses trips and prompts users to label them. However, users find the labeling process burdensome; less than half the trips are typically labeled, making much of the data unusable in aggregate analyses of mobility patterns. Prior work has addressed the response fatigue challenge through automated mode inference using sensor data, but sensors cannot capture all aspects of travel behavior. We explore an alternative approach in which we leverage prior user input to predict travel choices in novel trips. We first explore trip clustering methods and develop a novel two-step pipeline using DBSCAN and SVMs to extract realistic geospatial clusters. We then propose two strategies to predict trip labels: (i) clustering trips and extrapolating labels for similar trips, and (ii) random forest classification. The random forest approach is able to achieve - $70-80% accuracy (purpose: 72%, mode: 79%, replaced mode: 81%). These novel approaches to trip classification allow us to increase the rate of user labeling by suggesting predicted labels to be verified by the user. Unlabeled trips can also contribute to aggregate analyses, using label predictions and their associated confidences as a substitute. While there exist other travel survey apps with the ability to infer travel choices, to our knowledge, this is the first paper to describe such a supervised system and rigorously evaluate it.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

WE-F-304-05: Cranial TCP/NTCP Modeling Insights and Caveats

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-00: Outcomes of Hypofractionated Treatments - Results of the WGSBRT

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-01: Overview of the Working Group On Stereotactic Body Radiation Therapy (WGSBRT)

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-02: Recurrent HNC Treated with SBRT: TCP-Based Outcome Estimates

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-03: Optic Nerve/Chiasm Hypofractionated SRS/SRT Dose Tolerance

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-04: Radiosurgery for Vestibular Schwannomas: Tumor Control Probability Analyses and Recommended Reporting Standards

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

Confirmation of PNNL Quantitative Infrared Cross-Sections for Isobutane

The Pacific Northwest National Laboratory (PNNL) gas-phase database is a compilation of quantitative experimental (5, 25, 50 °C) infrared spectra of ca. 500 molecules, designed for in situ, standoff or remote sensing of gases and vapors at or near atmospheric pressure. The data are characterized by calibration on both the wavenumber and intensity axes. Recent papers have called into question the PNNL intensity values for isobutane, (2-methylpropane, HC(CH 3 ) 3 ) suggesting discrepancies of 30 to 40%. In this study we re-measure and re-examine the intensity values of isobutane using both similar and alternate methods to those used to generate the original PNNL database spectra. Here, indirect confirmation from literature data of homologous molecules and direct confirmation from new results confirm that for many band integrals across the isobutane spectrum, the original PNNL data are indeed accurate to within the reported 3% experimental uncertainty.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine learning-based real-time kinetic profile reconstruction in DIII-D

Abstract Kinetic equilibrium reconstruction plays a vital role in the physical analysis of plasma stability and control in fusion tokamaks. However, the traditional approach is subjective and prone to human biases. To address this, the consistent automatic kinetic equilibrium reconstruction (CAKE) method was introduced, providing objective results. Nonetheless, its offline nature limits its application in real-time plasma control systems (PCSs). To address this limitation, we present RTCAKENN, a machine learning model that approximates 7 CAKE-level output profiles, namely pressure, inverse q , toroidal current density, electron temperature and density, carbon ion impurity temperature and rotation profiles, using real-time available inputs. The deep neural network consists of an encoder layer, where the scalars and interdependent inputs such as plasma boundary coordinates and motional Stark effect data are encoded using multi-layer perceptrons (MLPs), while profile inputs are encoded by 1D convolutional layers. The encoded data is passed through a MLP for latent feature extraction, before being decoded in the decoding layers, which consist of upsampling and convolutional layers. RTCAKENN has been implemented in the DIII-D PCS and our model achieves accuracy comparable to CAKE and surpasses existing real-time alternatives. Through clever dropout training, RTCAKENN exhibits robustness and can operate even in the absence of Thomson scattering data or charge exchange recombination data. It executes in under 8 ms in the real-time environment, enabling future application in real-time control and analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Farmland Survey

A 1981 U.S. Department of Agriculture (USDA) study estimated that the nation is converting farmland to non-agricultural uses at the rate of 3 million acres a year. Seeking information on farmland loss in Florida, the state legislature, in 1984, directed establishment of a program for development of accurate data to enable intelligent legislation of state growth management. Thus was born Florida's massive Mapping and Monitoring of Agricultural Lands Project (MMALP). It employs data from the NASA-developed Landsat Earth resources survey satellite system as a quicker, less expensive alternative to ground surveying. The 3 year project involved inventory of Florida's 36 million acres classifying such as cropland, pastureland, citrus, woodlands, wetland, water and populated areas. Direction was assigned to Florida Department of Community Affairs (DCA) with assistance from the DOT. With the cooperation of the USDA, Soil Conservation Service, DCA decided that combining soil data with the Landsat land cover data would make available to land use planners a more comprehensive view of a county's land potential.

Source record↗