Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Relative intensity calibration of the DIII-D charge-exchange recombination spectroscopy system using neutral beam injection into gas

A new calibration method for the DIII-D charge-exchange spectroscopy system produces a smoother impurity density profile compared to previous techniques, thus improving the accuracy of the impurity density profile reconstruction. The relative intensity calibration between the chords of the DIII-D charge-exchange recombination spectroscopy system is performed by firing neutral beams into the evacuated vacuum vessel pre-filled with neutral gas. Relative calibration is required in order to account for uncertainty in the 3D geometry of the neutral beam. Previous methods using helium gas have been improved by using xenon, which emits an emission line close to the commonly used carbon wavelength 5290.5 Å, as well as improved timing of the gas injection, inclusion of variations in the vessel pressure, and timing of neutral beam injection. Photoemission spectra recorded by 112 sightlines viewing 6 neutral beams are compared and used to form a relative calibration factor for each sightline. This relative calibration is shown to improve the quality of the measured ion density profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-averaged Spray Analysis in the Near-field Using Broadband and Narrowband X-ray Measurements

The characterization of a spray in the near-field region is challenging because of its high optical density in this region. X-ray based techniques, with weak scatter and strong penetration properties, can provide better characterization than optical assessment techniques in this region. Here, the effects of various operating parameters on the optical depth (defined as the accumulated liquid thickness in the beam path times the X-ray attenuation coefficient) and spray profile of an atomizing spray in the near-field region are evaluated based on time-averaged X-ray analysis techniques. Controlling parameters in the spray structure include swirl ratio, liquid phase Reynolds number, and gas phase Reynolds number. Data from the broadband X-ray radiographs obtained using a tube source at Iowa State University and from focused beam measurements at the Advanced Photon Source at Argonne National Laboratory are compared. The X-ray tube source at Iowa State University was operated at two different energy levels, which reveals that the X-ray tube source energy influenced the magnitude of the optical depth but did not change the shape of the distribution. For the no swirl condition, gas flow rate and liquid flow rate had opposite effects on the spray profile, where the spray widens as the gas flow rate increases and narrows as the liquid flow rate increases. As the swirl ratio increases from 0 to 1, the spray widens and then narrows. Furthermore, the critical swirl ratio at which the spray reaches its widest spread differs at different flow conditions.

42 ENGINEERING↗

Evidence of E × B staircase in HL-2A L-mode tokamak discharges

Theory and simulation suggest the existence of an E ×B staircase in the plasma core consisting of a series of nested m/n = 0/0 E×B shear layers that regulate turbulent transport across the layers together with mesoscale transport events occurring between them. Here, we show evidence for these phenomena in HL-2A L-mode discharges. Both high resolution electron cyclotron emission Te profiles and frequency modulated continuous wave reflectometer ne profiles show multiple gradient corrugations. The analysis of simultaneous poloidally and radially separated beam emission spectroscopy turbulent density fluctuation measurements over most of the minor radius of the plasma provides the evidence of eddy tilting and propagation direction reversals largely coincident with the profile corrugations, with long-range transport events occurring between these locations. The results provide significant additional evidence for the existence of an E × B staircase that influences particle and heat transport in L-mode discharges.

Liu, Wenbin (ORCID:0000000310424117)↗

Modified Magnicon for High-Gradient Accelerator \&

A self-consistent design is described of a modified 34.3 GHz magnicon amplifier with a TE311-mode output cavity, to replace the existing magnicon at Yale Beam Physics Lab Test Facility whose output cavity operates in the TM310 mode. The main g oal for the new design is to achieve robust reliable operation. This is expected since tube performance according to simulations is largely insensitive to the magnitude of external dc magnetic fields, including imperfections in magnetic field profile; small changes in gun voltage and current; changes in electron beam radial size; and even poorly matched external circuitry. The new tube, as with its predecessor, is a third harmonic amplifier, with drive and deflection gain cavities near 11.424 GHz and output cavity at 34.272 GHz. The design calculations predict stable output of power of 20-27 MW at a 10 Hz repetition rate in pulses up to 1.3 microsec long, with a low probability of breakdown in the output cavity because of low electric fields (less tha n 650 kV/cm).

43 PARTICLE ACCELERATORS↗

SU-E-T-52: Beam Data Comparison for 20 Linear Accelerators in One Network

Purpose: To compare photon beam data for the 20 Varian linear accelerators (TrueBeam, iX, and EX models) in use at five centers in the same network with the intent to model with one set of beam data in Eclipsec. Methods: Varian linear accelerators, TrueBeam (3), 21 EX, iX, and Trilogy (14), and 6 EX (3), installed between 1999 and 2014 have their 6 MV and 15 MV x-ray beams reevaluated. Full commissioning, including output factors (St), percent depth doses (PDD), and off-axis profiles, was recently performed for a TrueBeam with a cc04 ion chamber in an IBA Blue phantom. Similarly, a subset of beam data for each of the other accelerators was measured recently as follows: for 3×3, 10×10, and 30×30 cm{sup 2} field sizes, flatness and penumbra (80–20%) were measured at dmax and 10 cm depths, PDD were measured at 10 and 20 cm depths, and St were measured at 5 cm depth. Measurement results for all machines were compared. Results: For 15 high-energy (6 and 15 MV) and 3 low-energy machines (6MV only): 1) PDD agreed within 1.4% at 10 and 20 cm depths; 2) penumbra agreed within 1.0 mm at dmax and 10 cm depths; 3) flatness was within 1.3% at dmax and 10 cm depths; and 4) with exception of the three low energy machines, output factors were within 1.1% and 0.5% for 3×3 and 30×30 cm{sup 2}, respectively. Measurement uncertainty, not quantified here, accounts for some of these differences. Conclusion: Measured beam data from 15 high-energy Varian linacs are consistent enough that they can be classified using one beam data set in Eclipse. Two additional high-energy machines are removed from this group until their data are further confirmed. Three low-energy machines will be in a separate class based upon differences in output factors (St)

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-203: Comparison of a Commercial MRI-Linear Accelerator Based Monte Carlo Dose Calculation Algorithm and Geant4

Purpose: An MRI-linear accelerator is currently being developed by the vendor Elekta™. The treatment planning system that will be used to model dose for this unit uses a Monte Carlo dose calculation algorithm, GPUMCD, that allows for the application of a magnetic field. We tested this radiation transport code against an independent Monte-Carlo toolkit Geant4 (v.4.10.01) both with and without the magnetic field applied. Methods: The setup comprised a 6 MeV mono-energetic photon beam emerging from a point source impinging on a homogeneous water phantom at 100 cm SSD. The comparisons were drawn from the percentage depth doses (PDD) for three different field sizes (1.5 x 1.5 cm{sup 2}, 5 x 5 cm{sup 2}, 10 x 10 cm{sup 2}) and dose profiles at various depths. A 1.5 T magnetic field was applied perpendicular to the direction of the beam. The transport thresholds were kept the same for both codes. Results: All of the normalized PDDs and profiles agreed within ± 1 %. In the presence of the magnetic field, PDDs rise more quickly reducing the depth of maximum dose. Near the beam exit point in the phantom a hot spot is created due to the electron return effect. This effect is more pronounced for the larger field sizes. Profiles selected parallel to the external field show no effect, however, the ones selected perpendicular to the direction of the applied magnetic field are shifted towards the direction of the Lorentz force applied by the magnetic field on the secondary electrons. It is observed that these profiles are not symmetric which indicates a lateral build up of the dose. Conclusion: There is a good general agreement between the PDDs/profiles calculated by both algorithms thus far. We are proceeding towards clinically relevant comparisons in a heterogeneous phantom for polyenergetic beams. Funding for this work has been provided by Elekta.

60 APPLIED LIFE SCIENCES↗

Drag reduction and the Vogel exponent of a flexible beam in transient shear flows

Interactions between a flexible beam and a fluid in a channel are of great relevance to biological hairy surfaces, aquatic vegetation, marine life (e.g., fish gills), and many industrial systems alike. While steady state response of a beam to such flows is fairly well-explored, their behavior in the transient regime is not fully understood. Here, a series of numerical simulations are performed to study the laminar Couette flow of an incompressible viscous fluid past an elastic beam in a two-dimensional channel. The flexible beam is perpendicular to the direction of flow, and its base is fixed to the stationary bottom of the channel. We measure the evolution of the Vogel exponent, drag reduction, and reconfiguration number during the transient and steady-state response of the fluid–structure system for different geometrical and physical properties. Our benchmark shows a good agreement between numerical and experimental observations. Our results show that the system's steady-state response at different bulk-fluid velocities can be reproduced by investigating the shear flow response during the transient regime. We define a new variable that characterizes the evolution of the local velocity profile in the proximity of the free end of the beam and use that to characterize the transient-regime response. The analysis yields insight into the competing effects of elasticity of the beam and non-linear flow response.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Extinction Measurements of Laser Side-Scatter During Tropical Storm Colin

A side-scatter imaging (SSI) technique using a 447 nm, 500 mW laser and a Nikon D80 camera was tested at Kennedy Space Center, Florida during the passing of a rain band associated with Tropical Storm Colin. The June 6, 2016, 22:00 GMT rain event was intense but short-lived owing to the strong west-to-east advection of the rain band. An effort to validate the optical extinction measurement was conducted by setting up a line of three tipping rain gauges along an 80 m east-west path and below the laser beam. Differences between tipping bucket measurements were correlated to the extinction coefficient profile along the lasers path, as determined by the SSI measurement. In order to compare the tipping bucket to the optical extinction data, a Marshall-Palmer DSD model was assumed. Since this was a daytime event, the laser beam was difficult to detect in the camera images, pointing out an important limitation of SSI measurements: the practical limit of DSD density that can be effectively detected and analyzed under daylight conditions using this laser and camera, corresponds to a fairly moderate rainfall rate on the order of 20 mmh (night measurements achieve a much improved sensitivity). The SSI analysis model under test produced promising results, but in order to use the SSI method for routine meteorological studies, improvements to the math model will be required.

optical extinction↗

Cylindrical surface profile and diameter measuring tool and method

A tool is shown having a cross beam assembly made of beams joined by a center box structure. The assembly is adapted to be mounted by brackets to the outer end of a cylindrical case. The center box structure has a vertical shaft rotatably mounted therein and extending beneath the assembly. Secured to the vertical shaft is a radius arm which is adapted to rotate with the shaft. On the longer end of the radius arm is a measuring tip which contacts the cylindrical surface to be measured and which provides an electric signal representing the radius of the cylindrical surface from the center of rotation of the radius arm. An electric servomotor rotates the vertical shaft and an electronic resolver provides an electric signal representing the angle of rotation of the shaft. The electric signals are provided to a computer station which has software for its computer to calculate and print out the continuous circumference profile of the cylindrical surface, and give its true diameter and the deviations from the ideal circle.

Currie, James R.↗

Effect of resistivity gradient on laser-driven electron transport and ion acceleration

The effect of resistivity gradient on laser-driven electron transport and ion acceleration is investigated using collisional particle-in-cell simulation. The study is motivated by recent proton acceleration experiments [Gizzi et al., Phys. Rev. ST Accel. Beams 14, 011301 (2011)], which showed significant effect of the resistivity gradient in layered targets on the proton angular spread. This effect is reproduced in the present simulations. It is found that resistivity-gradient generation of magnetic fields and inhibition of electron transport is significantly enhanced when the feedback interaction between the magnetic field and the fast-electron current is included. Filamentation of the laser-generated hot electron jets inside the target, considered as the origin of the nonuniform proton patterns observed in the experiments, is clearly suppressed by the resistive magnetic field. As a result, the electrostatic sheath field at the target back surface acquires a relatively smooth profile, which contributes to the superior quality of the proton beams accelerated off layered targets in the experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of meter-scale hydrogen plasmas and efficient, pump-depletion-limited wakefield excitation using 10 GeV electron bunches

High repetition rates and efficient energy transfer to the accelerating beam are important for a future linear collider based on the beam-driven plasma wakefield acceleration scheme (PWFA-LC). This paper reports the first results from the Plasma Wakefield Acceleration Collaboration (E300) that are beginning to address both of these issues using the recently commissioned FACET-II facility at SLAC national accelerator laboratory. Here we have generated meter-scale hydrogen plasmas using time-structured 10 GeV electron bunches from FACET-II, which hold the promise of dramatically increasing the repetition rate of PWFA by rapidly replenishing the gas between each shot compared to the hitherto used lithium plasmas that operate at 1–10 Hz. Furthermore, we have excited wakes in such plasmas that are suitable for high gradient particle acceleration with high drive-bunch to wake energy transfer efficiency- a first step in achieving a high overall energy transfer efficiency. We have done this by using time-structured electron drive bunches that typically have one or more ultra-high current (> 30 kA) femtosecond spike(s) superimposed on a longer (~0.4 ps) lower current (< 10 kA) bunch structure. The first spike effectively field-ionizes the gas and produces a meter-scale (30–160 cm) plasma, whereas the subsequent beam charge creates a wake. The length and amplitude of the wake depends on the longitudinal current profile of the bunch and plasma density. We find that the onset of pump depletion, when some of the drive beam electrons are nearly fully depleted of their energy, occurs for hydrogen pressure ≥ 1.5Torr. We also show that some electrons in the rear of the bunch can gain several GeV energies from the wake. These results are reproduced by particle-in-cell simulations using the QPAD code. At a pressure of ~2Torr, simulation results and experimental data show that the beam transfers about 60% of its energy to the wake.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new method for polychromatic X-ray μLaue diffraction on a Cu pillar using an energy-dispersive pn-junction charge-coupled device

μLaue diffraction with a polychromatic X-ray beam can be used to measure strain fields and crystal orientations of micro crystals. The hydrostatic strain tensor can be obtained once the energy profile of the reflections is measured. However, this remains a challenge both on the time scale and reproducibility of the beam position on the sample. In this review, we present a new approach to obtain the spatial and energy profiles of Laue spots by using a pn-junction charge-coupled device, an energy-dispersive area detector providing 3D resolution of incident X-rays. The morphology and energetic structure of various Bragg peaks from a single crystalline Cu micro-cantilever used as a test system were simultaneously acquired. The method facilitates the determination of the Laue spots’ energy spectra without filtering the white X-ray beam. The synchrotron experiment was performed at the BM32 beamline of ESRF using polychromatic X-rays in the energy range between 5 and 25 keV and a beam size of 0.5 μm × 0.5 μm. The feasibility test on the well known system demonstrates the capabilities of the approach and introduces the “3D detector method” as a promising tool for material investigations to separate bending and strain for technical materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation transfer in metallic-powder beds during laser forming

This paper presents numerical simulations of two-dimensional radiation transfer in a powder layer that resides on a substrate of the same material and is exposed to a normally incident laser beam with an axisymmetric bell-shaped or top-hat intensity profile. The powder layer is treated as an equivalent homogeneous absorbing/scattering medium with radiative properties defined by the reflectance of the solid phase, the porosity of the powder and its surface area. The model used is applicable when the laser beam diameter far exceeds the particle size of the powder. It is shown that the absorptance of an optically thick layer of opaque powder particles is a universal function of the absorptance of the solid phase and is independent of surface area and porosity, in agreement with experimental data in the literature. The fraction of laser energy absorbed in the powder-substrate system and that absorbed in the substrate decrease with an increase in the reflectance of the material, but the powder bed is then more uniformly heated. (laser technologies)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The real-time use of wind profilers in nowcasting

The program for Regional Observing and Forecasting Services (PROFS) has been using wind profile data in experimental forecast applications for over two years, mostly in the form of real-time color displays on the PROFS forecast workstation. The most ambitious test of the workstation to date, the 1985 PROFS Real-Time Experiment (RT-85), ran from 15 May to 23 August, 1985. The use of wind profiler products during this and previous experiments is described. Data from the experimental profiler network in Colorado and from the profiler in Oklahoma are in the form of hourly averages. Arriving data frequently contain errors whose origins range from interference by aircraft in the beams to highway truck traffic. Most of the irregularities are apparent through visual inspection of profiler wind observations plotted on a time-height cross section, but this method of quality control is inadequate if the intended uses of the data involve numerical calculations.

Smith, T. L.↗

Cylindrical surface profile and diameter measuring tool and method

A tool is shown having a cross beam assembly (15) made of beams (18, 19, 20, 21) joined by a center box structure (23). The assembly (15) is adapted to be mounted by brackets (16) to the outer end of a cylindrical case (11). The center box structure (23) has a vertical shaft (25) rotatably mounted therein and extending beneath the assembly (15). Secured to the vertical shaft (25) is a radius arm (28) which is adapted to rotate with shaft (25). On the longer end of the radius arm (28) is a measuring tip (30) which contacts the cylindrical surface to be measured and which provides an electric signal representing the radius of the cylindrical surface from the center of rotation of the radius arm (28). An electric servomotor (49) rotates the vertical shaft (25) and an electronic resolver (61) provides an electric signal representing the angle of rotation of the shaft (25). The electric signals are provided to a computer station (73) which has software for its computer to calculate and print out the continuous circumference profile of the cylindrical surface, and give its true diameter and the deviations from the ideal circle.

Currie, James R.↗

Dual ring multilayer ionization chamber and theory-based correction technique for scanning proton therapy

Purpose: To develop a multilayer ionization chamber (MLIC) and a correction technique that suppresses differences between the MLIC and water phantom measurements in order to achieve fast and accurate depth dose measurements in pencil beam scanning proton therapy. Methods: The authors distinguish between a calibration procedure and an additional correction: 1—the calibration for variations in the air gap thickness and the electrometer gains is addressed without involving measurements in water; 2—the correction is addressed to suppress the difference between depth dose profiles in water and in the MLIC materials due to the nuclear interaction cross sections by a semiempirical model tuned by using measurements in water. In the correction technique, raw MLIC data are obtained for each energy layer and integrated after multiplying them by the correction factor because the correction factor depends on incident energy. The MLIC described here has been designed especially for pencil beam scanning proton therapy. This MLIC is called a dual ring multilayer ionization chamber (DRMLIC). The shape of the electrodes allows the DRMLIC to measure both the percentage depth dose (PDD) and integrated depth dose (IDD) because ionization electrons are collected from inner and outer air gaps independently. Results: IDDs for which the beam energies were 71.6, 120.6, 159, 180.6, and 221.4 MeV were measured and compared with water phantom results. Furthermore, the measured PDDs along the central axis of the proton field with a nominal field size of 10 × 10 cm{sup 2} were compared. The spread out Bragg peak was 20 cm for fields with a range of 30.6 and 3 cm for fields with a range of 6.9 cm. The IDDs measured with the DRMLIC using the correction technique were consistent with those that of the water phantom; except for the beam energy of 71.6 MeV, all of the points satisfied the 1% dose/1 mm distance to agreement criterion of the gamma index. The 71.6 MeV depth dose profile showed slight differences in the shallow region, but 94.5% of the points satisfied the 1%/1 mm criterion. The 90% ranges, defined at the 90% dose position in distal fall off, were in good agreement with those in the water phantom, and the range differences from the water phantom were less than ±0.3 mm. The PDDs measured with the DRMLIC were also consistent with those that of the water phantom; 97% of the points passed the 1%/1 mm criterion. Conclusions: It was demonstrated that the new correction technique suppresses the difference between the depth dose profiles obtained with the MLIC and those obtained from a water phantom, and a DRMLIC enabling fast measurements of both IDD and PDD was developed. The IDDs and PDDs measured with the DRMLIC and using the correction technique were in good agreement with those that of the water phantom, and it was concluded that the correction technique and DRMLIC are useful for depth dose profile measurements in pencil beam scanning proton therapy.

60 APPLIED LIFE SCIENCES↗

Experimental Observations of Large-amplitude Solitary Waves in Electron Beams

The longitudinal dynamics of space charge dominated beams plays an important role in particle accelerators and other applications such as heavy ion fusion and free electron lasers (FELs). All beams are space-charge dominated near the source. F urthermore, the longitudinal profile is not necessarily an ideal mathematical function. By means of experiments on the University of Maryland Electron Ring (UMER), we studied how a perturbation to the line charge density could affect the beam propagation. By varying the initial amplitude of the perturbation, we access nonlinear space charge physics. When starting with large-amplitude perturbations, we have observed, for the first time in charged particle beams, solitary waves for which the nonlinear steep ening exactly balances the wave dispersion, leading to persistent waves that preserves their shape over a long distance. This paper presents the results of the soliton experiments, including systematic studies of the dependence of the soliton propagation on beam current, perturbation level and width. The data is compared with theory and simulation.

43 PARTICLE ACCELERATORS↗