Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Characteristics of electron velocity distribution functions in the solar wind derived from the Helios plasma experiment

The details of the shapes of three typical electron distribution functions observed by the Helios 1 and 2 probes in the solar wind between 0.3 AU and 1 AU are analyzed and compared with theoretical predictions. These are (1) a distribution function with a narrow 'strahl' (narrow beam), which is extremely anisotropic and skewed with respect to the magnetic field direction at particle energies above 100 eV; (2) a distribution function with a broad 'strahl', less anisotropic and skewed; and (3) a nearly isotropic distribution function. For each distribution function, a sudden change in the slope was discerned, separating the 'core' at lower energies from the 'halo' at higher energies. The most obvious differences of the analyzed electron distribution functions were observed at energies above 50-100 eV. The possible origins for the observed features of the distribution functions are discussed.

Pilipp, W. G.↗

Effect of the embolization material in the dose calculation for stereotactic radiosurgery of arteriovenous malformations

It is reported in the literature that the material used in an embolization of an arteriovenous malformation (AVM) can attenuate the radiation beams used in stereotactic radiosurgery (SRS) up to 10% to 15%. The purpose of this work is to assess the dosimetric impact of this attenuating material in the SRS treatment of embolized AVMs, using Monte Carlo simulations assuming clinical conditions. A commercial Monte Carlo dose calculation engine was used to recalculate the dose distribution of 20 AVMs previously planned with a pencil beam dose calculation algorithm. Dose distributions were compared using the following metrics: average, minimal and maximum dose of AVM, and 2D gamma index. The effect in the obliteration rate was investigated using radiobiological models. It was found that the dosimetric impact of the embolization material is less than 1.0 Gy in the prescription dose to the AVM for the 20 cases studied. The impact in the obliteration rate is less than 4.0%. There is reported evidence in the literature that embolized AVMs treated with SRS have low obliteration rates. This work shows that there are dosimetric implications that should be considered in the final treatment decisions for embolized AVMs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Coupled elastic response of open section laminated composite beams subject to generalized beam loading

A generalized beam theory for arbitrary open section laminated composite beams subjected to generalized beam loading is developed using a strength of materials approach. At present, the theory is limited to statistically determinate beams. Solution of the general system of equations yields strain and curvature distributions as functions of the axial coordinate x and the contour coordinate s. Average stresses on a given cross section or ply stresses in a local coordinate system are determined using these distributions. Data obtained for thin-walled open section composite beams reveal that elastic coupling occurs among curvatures, shearing strains, and axial strain, depending on the laminate stiffness parameters. Laminate ply layup does not affect the location of the shear center in the thin-wall approximation, but may have a significant impact for thicker walled open sections. The average axial stress distribution is found to be distinctly different from the isotropic distribution, but the average shear stress distribution is the same as that in the isotropic case.

Zvarick, Albert G.↗

Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system

Purpose: Intensity-modulated proton therapy (IMPT) using spot scanned proton beams relies on the delivery of a large number of beamlets to shape the dose distribution in a highly conformal manner. The authors have developed a 3D system based on liquid scintillator to measure the spatial location, intensity, and depth of penetration (energy) of the proton beamlets in near real-time. Methods: The detector system consists of a 20 x 20 x 20 cc liquid scintillator (LS) material in a light tight enclosure connected to a CCD camera. This camera has a field of view of 25.7 by 19.3 cm and a pixel size of 0.4 mm. While the LS is irradiated, the camera continuously acquires images of the light distribution produced inside the LS. Irradiations were made with proton pencil beams produced with a spot-scanning nozzle. Pencil beams with nominal ranges in water between 9.5 and 17.6 cm were scanned to irradiate an area of 10 x 10 cm square on the surface of the LS phantom. Image frames were acquired at 50 ms per frame. Results: The signal to noise ratio of a typical Bragg peak was about 170. Proton range measured from the light distribution produced in the LS was accurate to within 0.3 mm on average. The largest deviation seen between the nominal and measured range was 0.6 mm. Lateral position of the measured pencil beam was accurate to within 0.4 mm on average. The largest deviation seen between the nominal and measured lateral position was 0.8 mm; however, the accuracy of this measurement could be improved by correcting light scattering artifacts. Intensity of single proton spots were measured with precision ranging from 3 % for the smallest spot intensity (0.005 MU) to 0.5 % for the largest spot (0.04 MU). Conclusions: Our LS detector system has been shown to be capable of fast, submillimeter spatial localization of proton spots delivered in a 3D volume. This system could be used for beam range, intensity and position verification in IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron production from interactions of high-intensity ultrashort pulse laser with a planar deuterated polyethylene target

The deuteron acceleration from a planar uniform deuterated polyethylene (CD{sub 2}) target was studied with a two-dimensional electromagnetic particle-in-cell method in the ultrarelativistic regime for peak laser intensities between 10{sup 23} and 10{sup 25} W/m{sup 2}. Under identical conditions the deuteron energy and angular distributions are very different when compared to that produced from a double-layer target. The neutron production from D(d,n)-{sup 3}He nuclear fusion reactions was also investigated with a three-dimensional Monte Carlo ion beam-target deposition model. The neutron yield and its angular distribution were studied as a function of peak laser intensity and laser pulse duration. A neutron yield of 10{sup 4}-10{sup 6} neutrons per Joule laser energy is inferred from simulations of a 4 {mu}m thick planar uniform CD{sub 2} target. The angular scattering of neutrons is found to be nonisotropic and has a significant component in the forward (laser propagation) direction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identification of inversion domains in KTiOPO{sub 4}via resonant X-ray diffraction

The identification and high-resolution mapping of the absolute crystallographic structure in multi-domain ferroelectric KTiOPO{sub 4} is achieved through a novel synchrotron X-ray diffraction method. On a single Bragg reflection, the intensity ratio in resonant diffraction below and above the Ti absorption K edge demonstrates a domain contrast up to a factor of ∼270, thus implementing a non-contact, non-destructive imaging technique with micrometre spatial resolution, applicable to samples of arbitrarily large dimensions. A novel method is presented for the identification of the absolute crystallographic structure in multi-domain polar materials such as ferroelectric KTiOPO{sub 4}. Resonant (or ‘anomalous’) X-ray diffraction spectra collected across the absorption K edge of Ti (4.966 keV) on a single Bragg reflection demonstrate a huge intensity ratio above and below the edge, providing a polar domain contrast of ∼270. This allows one to map the spatial domain distribution in a periodically inverted sample, with a resolution of ∼1 µm achieved with a microfocused beam. This non-contact, non-destructive technique is well suited for samples of large dimensions (in contrast with traditional resonant X-ray methods based on diffraction from Friedel pairs), and its potential is particularly relevant in the context of physical phenomena connected with an absence of inversion symmetry, which require characterization of the underlying absolute atomic structure (such as in the case of magnetoelectric coupling and multiferroics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Total scatter factors of small beams: A multidetector and Monte Carlo study

The scope of this study was to estimate total scatter factors (s{sub c,p}) of the three smallest collimators of the Cyberknife radiosurgery system (5-10 mm in diameter), combining experimental measurements and Monte Carlo simulation. Two microchambers, a diode, and a diamond detector were used to collect experimental data. The treatment head and the detectors were simulated by means of a Monte Carlo code in order to calculate correction factors for the detectors and to estimate total scatter factors by means of a consistency check between measurement and simulation. Results for the three collimators were: s{sub c,p}(5 mm)=0.677{+-}0.004, s{sub c,p}(7.5 mm)=0.820{+-}0.008, s{sub c,p}(10 mm)=0.871{+-}0.008, all relative to the 60 mm collimator at 80 cm source-to-detector distance. The method also allows the full width at half maximum of the electron beam to be estimated; estimations made with different collimators and different detectors were in excellent agreement and gave a value of 2.1 mm. Correction factors to be applied to the detectors for the measurement of s{sub c,p} were consistent with a prevalence of volume effect for the microchambers and the diamond and a prevalence of scattering from high-Z material for the diode detector. The proposed method is more sensitive to small variations of the electron beam diameter with respect to the conventional method used to commission Monte Carlo codes, i.e., by comparison with measured percentage depth doses (PDD) and beam profiles. This is especially important for small fields (less than 10 mm diameter), for which measurements of PDD and profiles are strongly affected by the type of detector used. Moreover, this method should allow s{sub c,p} of Cyberknife systems different from the unit under investigation to be estimated without the need for further Monte Carlo calculation, provided that one of the microchambers or the diode detector of the type used in this study are employed. The results for the diamond are applicable only to the specific detector that was investigated due to excessive variability in manufacturing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrostatic charging of spacecraft in response to electron beam injection

Electron beam injections from spacecraft now constitute a major activity in space research. Here, the charging level of a conducting surface when an electron beam is injected from it is investigated. Injections into both vacuum and an ambient plasma are considered. When a Maxwellian beam is injected into vacuum, the surface changes to a potential much greater than the average beam energy. The dependence of this excess is examined by considering beams with water-bag types of velocity distribution functions in which no electron has a velocity V(max) above a certain value. The electric field distribution in the electron sheath near the surface is determined by the pressure distribution. Thus, the surface potential is determined not only by V(max) but by all the beam parameters. The ambient plasma reduces the charging level and causes an oscillation in the surface potential. The oscillation frequency is the electron-plasma frequency associated with the ambient plasma.

Singh, Nagendra↗

Min-Bias at the Tevatron

As illustrated in Fig. 1, the total proton-antiproton cross section is the sum of the elastic and inelastic components, {sigma}{sub tot} = {sigma}{sub EL} + {sigma}{sub IN}. The inelastic cross section consists of three terms; single diffraction, double-diffraction, and everything else (referred to as the 'hard core'), {sigma}{sub IN} = {sigma}{sub SD} + {sigma}{sub DD} + {sigma}{sub HC}. For elastic scattering neither of the beam particles breaks apart (i.e. color singlet exchange). For single and double diffraction one or both of the beam particles are excited into a high mass color singlet state (i.e. N* states) which then decays. Single and double diffraction also corresponds to color singlet exchange between the beam hadrons. When color is exchanged the outgoing remnants are no longer color singlets and one has a separation of color resulting in a multitude of quark-antiquark pairs being pulled out of the vacuum. The 'hard core' component, {sigma}{sub HC}, involves color exchange and the separation of color. However, the 'hard core' contribution has both a 'soft' and 'hard' component. Most of the time the color exchange between partons in the beam hadrons occurs through a soft interaction (i.e. no high transverse momentum) and the two beam hadrons 'ooze' through each other producing lots of soft particles with a uniform distribution in rapidity and many particles flying down the beam pipe. Occasionally there is a hard scattering among the constituent partons producing outgoing particles and 'jets' with high transverse momentum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-G-TeP3-09: Proton Minibeam Radiation Therapy Increases Normal Tissue Resistance

Purpose: The dose tolerances of normal tissues continue being the main limitation in radiotherapy. To overcome it, we recently proposed a novel concept: proton minibeam radiation therapy (pMBRT) [1]. It allies the physical advantages of protons with the normal tissue preservation observed when irradiated with submillimetric spatially fractionated beams (minibeam radiation therapy) [2]. The dose distributions are such that the tumor receives a homogeneous dose distribution, while normal tissues benefit from the spatial fractionation of the dose. The objective of our work was to implement this promising technique at a clinical center (Proton therapy center in Orsay) in order to evaluate the potential gain in tissue sparing. Methods: Dose distributions were measured by means of gafchromic films and a PTW microdiamond detector (60019). Once the dosimetry was established, the whole brain of 7 weeks old male Fischer 344 rats was irradiated. Half of the animals received conventional seamless proton irradiation (25 Gy in one fraction). The other rats were irradiated with pMBRT (58 Gy peak dose in one fraction). The average dose deposited in the same targeted volume was in both cases 25 Gy. Results: The first complete set of dosimetric data in such small proton field sizes was obtained [3]. Rats treated with conventional proton irradiation exhibited severe moist desquamation and permanent epilation afterwards. The minibeam group, on the other hand, exhibited no skin damage and no clinical symptoms. MRI imaging and histological analysis are planned at 6 months after irradiation. Conclusion: Our preliminary results indicate that pMBRT leads to an increase in tissue resistance. This can open the door to an efficient treatment of very radioresistant tumours. [1] Prezado et al. Med. Phys. 40, 031712, 1–8 (2013).[2] Prezado et al., Rad. Research. 184, 314-21 (2015). [3] Peucelle et al., Med. Phys. 42 7108-13 (2015).

60 APPLIED LIFE SCIENCES↗

SU-F-T-53: Treatment Planning with Inhomogeneity Correction for Intraoperative Radiotherapy Using KV X-Ray Beams

Purpose: The current standard in dose calculation for intraoperative radiotherapy (IORT) using the ZEISS Intrabeam 50 kV x-ray system is based on depth dose measurements in water and no heterogeneous tissue effect has been taken into account. We propose an algorithm for pre-treatment planning including inhomogeneity correction based on data of depth dose measurements in various tissue phantoms for kV x-rays. Methods: Direct depth dose measurements were made in air, water, inner bone and cortical bone phantoms for the Intrabeam 50 kV x-rays with a needle applicator. The data were modelled by a function of power law combining exponential with different parameters. Those phantom slabs used in the measurements were scanned to obtain CT numbers. The x-ray beam initiated from the source isocenter is ray-traced through tissues. The corresponding doses will be deposited/assigned at different depths. On the boundary of tissue/organ changes, the x-ray beam will be re-traced in new tissue/organ starting at an equivalent depth with the same dose. In principle, a volumetric dose distribution can be generated if enough directional beams are traced. In practice, a several typical rays traced may be adequate in providing estimates of maximum dose to the organ at risk and minimum dose in the target volume. Results: Depth dose measurements and modeling are shown in Figure 1. The dose versus CT number is shown in Figure 2. A computer program has been written for Kypho-IORT planning using those data. A direct measurement through 2 mm solid water, 2 mm inner bone, and 1 mm solid water yields a dose rate of 7.7 Gy/min. Our calculation shows 8.1±0.4 Gy/min, consistent with the measurement within 5%. Conclusion: The proposed method can be used to more accurately calculate the dose by taking into account the heterogeneous effect. The further validation includes comparison with Monte Carlo simulation.

60 APPLIED LIFE SCIENCES↗

Methods and Devices for Space Optical Communications Using Laser Beams

Light is used to communicate between objects separated by a large distance. Light beams are received in a telescopic lens assembly positioned in front of a cat's-eye lens. The light can thereby be received at various angles to be output by the cat's-eye lens to a focal plane of the cat's-eye lens, the position of the light beams upon the focal plane corresponding to the angle of the beam received. Lasers and photodetectors are distributed along this focal plane. A processor receives signals from the photodetectors, and selectively signal lasers positioned proximate the photodetectors detecting light, in order to transmit light encoding data through the cat's-eye lens and also through a telescopic lens back in the direction of the received light beams, which direction corresponds to a location upon the focal plane of the transmitting lasers.

Goorjian, Peter M.↗

KINETIC ALFVÉN WAVE GENERATION BY LARGE-SCALE PHASE MIXING

One view of the solar wind turbulence is that the observed highly anisotropic fluctuations at spatial scales near the proton inertial length d{sub p} may be considered as kinetic Alfvén waves (KAWs). In the present paper, we show how phase mixing of large-scale parallel-propagating Alfvén waves is an efficient mechanism for the production of KAWs at wavelengths close to d{sub p} and at a large propagation angle with respect to the magnetic field. Magnetohydrodynamic (MHD), Hall magnetohydrodynamic (HMHD), and hybrid Vlasov–Maxwell (HVM) simulations modeling the propagation of Alfvén waves in inhomogeneous plasmas are performed. In the linear regime, the role of dispersive effects is singled out by comparing MHD and HMHD results. Fluctuations produced by phase mixing are identified as KAWs through a comparison of polarization of magnetic fluctuations and wave-group velocity with analytical linear predictions. In the nonlinear regime, a comparison of HMHD and HVM simulations allows us to point out the role of kinetic effects in shaping the proton-distribution function. We observe the generation of temperature anisotropy with respect to the local magnetic field and the production of field-aligned beams. The regions where the proton-distribution function highly departs from thermal equilibrium are located inside the shear layers, where the KAWs are excited, this suggesting that the distortions of the proton distribution are driven by a resonant interaction of protons with KAW fluctuations. Our results are relevant in configurations where magnetic-field inhomogeneities are present, as, for example, in the solar corona, where the presence of Alfvén waves has been ascertained.

79 ASTRONOMY AND ASTROPHYSICS↗

Adaptively pointing spaceborne radar for precipitation measurements

An auxiliary concept of adaptive pointing is presented as an aid to space-based measurements of precipitation using microwave radar. It is recommended that the instantaneous field of view (IFOV) be limited to cloudy regions of possible precipitation rather than scanning clear-sky areas of no interest. A microwave imager is proposed for scanning ahead of the satellite in order to identify areas of precipitation, and then an on-board antenna controller can reposition the scanning antenna to obtain reflectivities for use in rainfall-reflectivity relationships. The precursor beam could delineate the storm boundaries and determine points of peak intensity which can then be selectively sampled to find the rainfall rate distribution for the storm. The adaptive-beam system is suggested to be implementable using an IR sensor on-board geosynchronous satellites.

Atlas, D.↗

Identification and control of a flexible beam using modal domain sensor

The use of a distributed-effect, modal domain optical fiber sensor (MD sensor) as a component in an active control system to suppress vibrations in a flexible beam is discussed. The sensor model is integrated into the model for a flexible structure. Based on this system model, a control system with a dynamic compensator is designed to add damping to the low order modes of the flexible structure. To verify the modeling procedure, a cantilevered beam was instrumental with a piezoelectric actuator and an MD sensor. It is shown that experimental responses closely match simulated responses for both open loop and closed loop tests.

Cox, David E.↗

High-Energy Delayed Gamma Spectroscopy for Spent Nuclear Fuel Assay

High-accuracy, direct, nondestructive measurement of fissile and fissionable isotopes in spent fuel, particularly the Pu isotopes, is a well-documented, but still unmet challenge in international safeguards. As nuclear fuel cycles propagate around the globe, the need for improved materials accountancy techniques for irradiated light-water reactor fuel will only increase (e.g. for shipper-receiver verification at interim or permanent storage, or at the head end of a reprocessing plant). This modeling study investigates the use of delayed gamma rays from fission-product nuclei to directly measure the relative concentrations of U-235, Pu-239, and Pu-241 in spent fuel assemblies. The method is based on the unique distribution of fission-product nuclei produced from fission in each of these fissile isotopes. Fission is stimulated in the assembly with a beam of interrogating neutrons and the measured distributions of the short-lived fission products from the unknown sample are then fit with a linear combination of the known fission-product yield curves from pure U-235, Pu-239, and Pu-241 to determine the original proportions of these fissile isotopes. Modeling approaches for the intense gamma-ray background promulgated by the long-lived fission-product inventory, and the high-energy gamma-ray signatures emitted by short-lived fission products from induced fission are described. Results for the simulated assay of simplified individual fuel elements ranging from fresh to 60 GWd/MTU burnup are used to demonstrate the utility of the modeling methods and provide preliminary viability data for the technique. A limited set of benchmarking measurements, and additional work needed to more realistically assess the potential of the High-Energy Delayed Gamma Spectroscopy (HEDGS) technique are described.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Kapton charging characteristics: Effects of material thickness and electron-energy distribution

Charging characteristics of polyimide (Kapton) of varying thicknesses under irradiation by a very-low-curent-density electron beam, with the back surface of the sample grounded are reported. These charging characteristics are in good agreement with a simple analytical model which predicts that in thin samples at low current density, sample surface potential is limited by conduction leakage through the bulk material. The charging of Kapton in a low-current-density electron beam in which the beam energy was modulated to simulate Maxwellian and biMaxwellian distribution functions is measured.

Williamson, W. S.↗

Observations of electron beams in the low-latitude boundary layer

ISEE 1 electron spectrometer observations are used to study the electron distribution function in the low latitude boundary layer (LLBL) of the magnetosphere in the sunward direction. The study included 43 examples of well-defined layers. Using three-dimensional, model-independent distribution functions of electrons observed in the boundary layer, beams of field-aligned electrons with typically 100 eV energy maximums, streaming in either one, or both, directions have been identified. The phase densities in the LLBL and at lower altitudes are similar, and the beams observed in the LLBL are identified with those observed at lower altitudes. They form an important component of the plasma electrons in the LLBL, which otherwise resembles a mixture of magnetosheath-like and magnetospheric electrons.

Ogilvie, K. W.↗