Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Enabling a Voice Management System for Space Applications

The sustainable missions beyond Low Earth Orbit (LEO) envisioned for NASA’s Artemis program will require autonomous capabilities. Moreover, Artemis mission crews will need a means to efficiently interact with a spacecraft’s autonomous systems. This interaction can be facilitated by voice and speech communications because voice-based controls enable users to interact hands- and eyes-free, allowing the user to better focus on critical tasks. The goal of our project was to explore the knowledge and technology needed to successfully design effective Voice User Interfaces (VUIs) for autonomous systems utilizing Human Centered Design (HCD) principles. The focus of the human factors’ aspect of engineering, pays close attention to psychological and physiological principles in the development of autonomous crew operation systems. A main objective was to understand how a crew member, through voice interaction, could efficiently and intuitively communicate with a notional autonomous vehicle system manager. This project was a part of the NASA Moon to Mars eXploration Systems and Habitation (M2M X-Hab) 2020 Academic Innovation Challenge. The work from the BLiSS Team, at the University of Michigan, resulted in the design of a system persona, Diego, to which an astronaut may quickly build trust with autonomous systems, to alleviate known stressors on mental health expected during long duration space missions. Optimal software to facilitate integration of the system persona into a reference Lunar orbiting Gateway station was defined. Additionally, a Speech to Text (STT) system and a Graphical User Interface (GUI) that could be implemented in future missions was developed on an Internet of Things (IOT) platform. The Voice User Interface (VUI) design for the M2M X-Hab 2020 project leveraged previous technology developed by the BLiSS team to incorporate a voice-based interface into NASA’s Platform for Autonomous Systems (NPAS) software. This required technologies to convert voice to text, conduct semantic interpretations, and convert responses from the autonomous system to text and to speech; additionally, the spacecraft background noise environment was assessed, a noise mitigation technique was developed, and a relatable personality for the autonomous system was developed in order to facilitate human-like conversations. The success of our effort was largely due to the diversity of the team that included expertise in Space Systems Engineering, Human Computer Interaction, Aerospace Engineering, Computer Science, Biomedical Engineering, and Applied Physics. The diverse perspectives fostered elaborate discussions, resulting in the conception of three main subsystems: (1) User-System, (2) NPAS-System, and (3) Environment-System. The VUI was unique and had to be efficient and intuitive. For this project, 5 subteams were formed, each with a separate objective, Voice Design team, Background Noise Mitigation team, Software Integration team and Graphical User Interface team. The BLiSS team crafted a personality for the VUI to enable human-like conversation and drive user adoption and trust. User surveys were completed and used to help determine the required VUI system personality traits by capturing perspectives and expectations of prospective “Artemis Generation Astronauts”. To further simulate human-like conversations, the system had to be able to quickly interpret user speech and be able to integrate with NASA’s NPAS platform for quick and reliable information transfer. The outcomes of our research were: (1) a working prototype user interface, that is compatible with NASA’s NPAS platform; (2) software that demonstrates the ability of the VUI system to interpret user requests and respond appropriately; (3) the capability to implement fully expanded conversations between user and system using intuitive communication in four request categories; and (4) software and hardware recommendations that optimize the system’s ability to operate in a noisy environment. Our research has laid the foundation for the development of VUI’s for autonomy, and provides a baseline for future VUI developments.

Voice user interface↗

SU-E-T-244: Designing Low-Z Targets To Enhance Surface Dose: A Monte Carlo Simulation

Purpose: Recent developments in The Varian Truebeam linac platform allows for the introduction of low-Z targets into the beam line for the imaging purposes. We have proposed using a low-Z target for radiation therapy purposes to enhance the surface dose during radiation treatment. The target arm of the Varian Truebeam accelerator consists of multiple targets with are linearly translated into the beam line. We have designed two Low-Z targets made of carbon: 1) a step target consisting of three steps of 15%, 30% and 60% CSDA range for 2.5 MeV electrons Figure 1a; 2) and a ramp target, an incline plane 2cm long with thicknesses ranging from 0% to 60% CSDA range, Figure 1b. The purpose of this work will determine the spectral characteristics of these target designs and determine if they have practical clinical applications for enhancing surface dose. Methods: To calculate the spectral characteristics of these targets, a standard Monte Carlo model of a Varian Clinac accelerator was used. Simulations were performed with a carbon step target, and a carbon ramp target, located at the same position as the electron foil in the rotating carousel. Simulations were carried out using a 2.5 MeV electron beam. Results: The step target design produced spectral characteristics which were similar to spectral model using a single disk target of the same thickness. The ramp target provides a means to have positional variation of the spectral components of the beam, however, the electron component as 60% CSDA us much broader than the step target. Conclusion: The carbon step-target provides a spectral distribution which is similar to a carbon disk of comparable thickness. The spectral distribution from the ramp-target can be modified as a function of position to provide a wide range of low energy electrons for surface dose enhancement.

60 APPLIED LIFE SCIENCES↗

Current Status of Interventional Radiology Treatment of Infrapopliteal Arterial Disease

Treatment of infrapopliteal arteries has developed to a standard technique during the past two decades. With the introduction of innovative devices, a variety of techniques has been created and is still under investigation. Treatment options range from plain balloon angioplasty (POBA), all sorts of stent applications, such as bare metal, balloon expanding, self-expanding, coated and drug-eluting stents, and bio-absorbable stents, to latest developments, such as drug-eluting balloons. Regarding the scientific background, several prospective, randomized studies with relevant numbers of patients have been (or will be) published that are Level I evidence. In contrast to older studies, which primarily were based mostly on numeric parameters, such as diameters or residual stenoses, more recent study concepts focus increasingly on clinical features, such as amputation rate improvement or changes of clinical stages and quality of life standards. Although it is still not decided, which of the individual techniques might be the best one, we can definitely conclude that whatever treatment of infrapopliteal arteries will be used it is of substantial benefit for the patient. Therefore, the goal of this review is to give an overview about the current developments and techniques for the treatment of infrapopliteal arteries, to present clinical and technical results, to weigh individual techniques, and to discuss the recent developments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Waterproof AlInGaP optoelectronics on stretchable substrates with applications in biomedicine and robotics

Inorganic light-emitting diodes and photodetectors represent important, established technologies for solid-state lighting, digital imaging and many other applications. Eliminating mechanical and geometrical design constraints imposed by the supporting semiconductor wafers can enable alternative uses in areas such as biomedicine and robotics. Here we describe systems that consist of arrays of interconnected, ultrathin inorganic light-emitting diodes and photodetectors configured in mechanically optimized layouts on unusual substrates. Light-emitting sutures, implantable sheets and illuminated plasmonic crystals that are compatible with complete immersion in biofluids illustrate the suitability of these technologies for use in biomedicine. Waterproof optical-proximity-sensor tapes capable of conformal integration on curved surfaces of gloves and thin, refractive-index monitors wrapped on tubing for intravenous delivery systems demonstrate possibilities in robotics and clinical medicine. Furthermore, these and related systems may create important, unconventional opportunities for optoelectronic devices.

36 MATERIALS SCIENCE↗

Fourth Annual Workshop on Space Operations Applications and Research (SOAR 90)

The papers presented at the Space Operations, Applications and Research (SOAR) Symposium, hosted by the Air Force Space Technology Center and held at Albuquerque, New Mexico, on June 26-28, 1990, are documented in these proceedings. Over 150 technical papers were presented at the Symposium, which was jointly sponsored by the Air Force and NASA Johnson Space Center. the technical areas included were: Automation and Robotics, Environmental Interactions, Human Factors, Intelligent Systems, and Life Sciences. NASA and Air Force programmatic overviews and panel sessions were also held in each technical area. These proceedings, along with the comments by technical area coordinators and session chairmen, will be used by the Space Operation Technology Subcommittee (SOTS) of the Air Force Systems Command and NASA Space Technology Interdependency Group (STIG) to assess the status of the technology, as well as the joint projects/activities in various technical areas. The Symposium proceedings include papers presented by experts from NASA, the Air Force, universities, and industries in various disciplines.

Life Sciences↗

SU-F-T-19: The Consistency Dosimetric Analysis of the Accelerated Breast Brachytherapy

Purpose: To assess the best approach in accept a treatment plan for APBI Savi patients. Should we run a treatment verification test prior to delivering it to the patient? Should we check each CT scan in regards to the initial one in dosimetrical terms? Do we need deformable registration and adaptive planning for each fraction? These are the questions we want to answer running a dosimetric analysis of the dose variances for APBI treatments who receive 10 fractions and no re-planning has been done being considered unnecessary with today’s means of assessment. Methods: A retrospective analysis of 30 patients treated with SAVI applicators were considered for this study. The CT scans taken before each treatment were imported in the treatment planning system and registered with the initial CT scan. The images were fused together with respective to the applicator, using landmark registration. Dosimetric evaluations were performed. Dose received by skin, ribs and PTV on CT images with respect to the initial treatment plan were recorded including maximum, average and minimum dose Results: All the structures displayed changes in volume over the 10 fractions of treatment. The cavities reduction in volume was considerable with a maximum reduction of over 10%. The PTV-eval is covered better due to this fact while the critical organs manifest an increase in the total and maximum dose delivered. Ribs and skin surface that are required by B39 protocol to be monitored can acquire maximum doses of 20% to 30% respectively. Conclusion: A dosimetric evaluation prior to the initial treatment and prior to each of the 10 fractions is proven to be necessary. Deformable registration and adaptive planning have to be studied more and eventually implemented for every patient who received more than one fraction of any type of brachytherapy treatment. Immobilization ad localization methods must be improved and studied further.

60 APPLIED LIFE SCIENCES↗

Dosimetric characterization and organ dose assessment in digital breast tomosynthesis: Measurements and Monte Carlo simulations using voxel phantoms

Purpose: Due to its capability to more accurately detect deep lesions inside the breast by removing the effect of overlying anatomy, digital breast tomosynthesis (DBT) has the potential to replace the standard mammography technique in clinical screening exams. However, the European Guidelines for DBT dosimetry are still a work in progress and there are little data available on organ doses other than to the breast. It is, therefore, of great importance to assess the dosimetric performance of DBT with respect to the one obtained with standard digital mammography (DM) systems. The aim of this work is twofold: (i) to study the dosimetric properties of a combined DBT/DM system (MAMMOMAT Inspiration Siemens{sup ®}) for a tungsten/rhodium (W/Rh) anode/filter combination and (ii) to evaluate organs doses during a DBT examination. Methods: For the first task, measurements were performed in manual and automatic exposure control (AEC) modes, using two homogeneous breast phantoms: a PMMA slab phantom and a 4 cm thick breast-shaped rigid phantom, with 50% of glandular tissue in its composition. Monte Carlo (MC) simulations were performed using Monte Carlo N-Particle eXtended v.2.7.0. A MC model was implemented to mimic DM and DBT acquisitions for a wide range of x-ray spectra (24 –34 kV). This was used to calculate mean glandular dose (MGD) and to compute series of backscatter factors (BSFs) that could be inserted into the DBT dosimetric formalism proposed by Dance et al. Regarding the second aim of the study, the implemented MC model of the clinical equipment, together with a female voxel phantom (“Laura”), was used to calculate organ doses considering a typical DBT acquisition. Results were compared with a standard two-view mammography craniocaudal (CC) acquisition. Results: Considering the AEC mode, the acquisition of a single CC view results in a MGD ranging from 0.53 ± 0.07 mGy to 2.41 ± 0.31 mGy in DM mode and from 0.77 ± 0.11 mGy to 2.28 ± 0.32 mGy in DBT mode. Regarding the BSF, the results achieved may lead to a MGD correction of about 6%, contributing to the improvement of the current guidelines used in these applications. Finally, considering the MC results obtained for the organ dose study, the radiation doses found for the tissues of the body other than the breast were in the range of tens of μSv, and are in part comparable to the ones obtained in standard DM. Nevertheless, in a single DBT examination, some organs (such as lung and thyroid) receive higher doses (of about 9% and 21%, respectively) with respect to the CC DM acquisition. Conclusions: Taking into account an average breast with a thickness of 4.5 cm, the MGDs for DM and DBT acquisitions were below the achievable value (2.0 mGy) defined by the European protocol. Additionally, in the case of a fusion imaging study (DM + DBT), the MGD for a 4.5 cm thick breast is of the order of 1.88 ± 0.36 mGy. Finally, organ dose evaluations underline the need to improve awareness concerning dose estimation of DBT exams for some organs, especially when radiation risk is assessed by using the effective dose.

60 APPLIED LIFE SCIENCES↗

A Route to Design Novel Functional Peptides by Applying a Denoising Diffusional Model to mRNA Display Libraries

In vitro directed evolution techniques, such as mRNA display, enable peptide ligand discovery and optimization. However, physical libraries that rely on a genetic code can only search a small fraction of sequence space due to inherent biases in the genetic code and experimental limitations. To address this challenge, denoising diffusion implicit models (DDIMs) are applied to generate novel peptide ligands against B‐cell lymphoma extra‐large (Bcl‐x L ), a key cancer target. Starting with high‐throughput sequencing data from previous selections, a DDIM is trained to produce novel sequences with high affinity binding. Experimental validation confirms that most generated sequences are functionally equivalent to the original library members for Bcl‐x L binding and demonstrated comparable binding kinetics and affinity relative to the wildtype and nearest original neighbors. Importantly, this approach generated rare sequences not easily accessible via mutation and directed evolution. These results indicate that DDIMs can complement and expand directed evolution data, efficiently exploring underrepresented regions of sequence space. This approach provides a broadly applicable framework for accelerating ligand discovery and optimizing molecular properties across diverse targets.

Qi, Pearl [Mork Family Department of Chemical Engi↗

WE-G-BRF-04: Robust Real-Time Volumetric Imaging Based On One Single Projection

Purpose: Real-time volumetric imaging is highly desirable to provide instantaneous image guidance for lung radiation therapy. This study proposes a scheme to achieve this goal using one single projection by utilizing sparse learning and a principal component analysis (PCA) based lung motion model. Methods: A patient-specific PCA-based lung motion model is first constructed by analyzing deformable vector fields (DVFs) between a reference image and 4DCT images at each phase. At the training stage, we “learn” the relationship between the DVFs and the projection using sparse learning. Specifically, we first partition the projections into patches, and then apply sparse learning to automatically identify patches that best correlate with the principal components of the DVFs. Once the relationship is established, at the application stage, we first employ a patchbased intensity correction method to overcome the problem of different intensity scale between the calculated projection in the training stage and the measured projection in the application stage. The corrected projection image is then fed to the trained model to derive a DVF, which is applied to the reference image, yielding a volumetric image corresponding to the projection. We have validated our method through a NCAT phantom simulation case and one experiment case. Results: Sparse learning can automatically select those patches containing motion information, such as those around diaphragm. For the simulation case, over 98% of the lung region pass the generalized gamma test (10HU/1mm), indicating combined accuracy in both intensity and spatial domain. For the experimental case, the average tumor localization errors projected to the imager are 0.68 mm and 0.4 mm on the axial and tangential direction, respectively. Conclusion: The proposed method is capable of accurately generating a volumetric image using one single projection. It will potentially offer real-time volumetric image guidance to facilitate lung radiotherapy. This study is supported in part by NIH (1R01CA154747-01), The Core Technology Research in Strategic Emerging Industry, Guangdong, China(2011A081402003)

60 APPLIED LIFE SCIENCES↗

Advancements in Ti Alloy Powder Production by Close-Coupled Gas Atomization

As the technology for titanium metal injection molding (Ti-MIM) becomes more readily available, efficient Ti alloy fine powder production methods are required. An update on a novel close-coupled gas atomization system has been given. Unique features of the melting apparatus are shown to have measurable effects on the efficiency and ability to fully melt within the induction skull melting system (ISM). The means to initiate the melt flow were also found to be dependent on melt apparatus. Starting oxygen contents of atomization feedstock are suggested based on oxygen pick up during the atomization and MIM processes and compared to a new ASTM specification. Forming of titanium by metal injection molding (Ti-MIM) has been extensively studied with regards to binders, particle shape, and size distribution and suitable de-binding methods have been discovered. As a result, the visibility of Ti-MIM has steadily increased as reviews of technology, acceptability, and availability have been released. In addition, new ASTM specification ASTM F2885-11 for Ti-MIM for biomedical implants was released in early 2011. As the general acceptance of Ti-MIM as a viable fabrication route increases, demand for economical production of high quality Ti alloy powder for the preparation of Ti-MIM feedstock correspondingly increases. The production of spherical powders from the liquid state has required extensive pre-processing into different shapes thereby increasing costs. This has prompted examination of Ti-MIM with non-spherical particle shape. These particles are produced by the hydride/de-hydride process and are equi-axed but fragmented and angular which is less than ideal. Current prices for MIM quality titanium powder range from $40-$220/kg. While it is ideal for the MIM process to utilize spherical powders within the size range of 0.5-20 {mu}m, titanium's high affinity for oxygen to date has prohibited the use of this powder size range. In order to meet oxygen requirements the top size cut has traditionally been 45 {mu}m, and in some instances a bottom cut at +5 {mu}m is made to remove ultra-fine particles and reduce oxygen content. Predictably, use of irregular shaped or larger particle feedstock powder can reduce part quality as sintering shrinkage and part detail suffer. Thus, widespread production and technological use of Ti-MIM is limited due in large part to Ti alloy feedstock cost and availability, not MIM processing capability. Lower cost feedstock of fine, spherical Ti alloy powder with sufficient purity must be available in order to fully utilize the advantages of the Ti-MIM processing route allowing expansion of the market to small complex Ti parts in many high volume applications.

36 MATERIALS SCIENCE↗

SU-C-BRD-05: Non-Invasive in Vivo Biodosimetry in Radiotherapy Patients Using Electron Paramagnetic Resonance (EPR) Spectroscopy

Purpose: Medical intervention following a major, unplanned radiation event can elevate the human whole body exposure LD50 from 3 to 7 Gy. On a large scale, intervention cannot be achieved effectively without accurate and efficient triage. Current methods of retrospective biodosimetry are restricted in capability and applicability; published human data is limited. We aim to further develop, validate, and optimize an automated field-deployable in vivo electron paramagnetic resonance (EPR) instrument that can fill this need. Methods: Ionizing radiation creates highly-stable, carbonate-based free radicals within tooth enamel. Using a process similar to nuclear magnetic resonance, EPR directly measures the presence of radiation-induced free radicals. We performed baseline EPR measurements on one of the upper central incisors of total body irradiation (TBI) and head and neck (H&N) radiotherapy patients before their first treatment. Additional measurements were performed between subsequent fractions to examine the EPR response with increasing radiation dose. Independent dosimetry measurements were performed with optically-stimulated luminescent dosimeters (OSLDs) and diodes to more accurately establish the relationship between EPR signal and delivered radiation dose. Results: 36 EPR measurements were performed over the course of four months on two TBI and four H & N radiotherapy patients. We observe a linear increase in EPR signal with increasing dose across the entirety of the tested range. A linear least squares-weighted fit of delivered dose versus measured signal amplitude yields an adjusted R-square of 0.966. The standard error of inverse prediction (SEIP) is 1.77 Gy. For doses up to 7 Gy, the range most relevant to triage, we calculate an SEIP of 1.29 Gy. Conclusion: EPR spectroscopy provides a promising method of retrospective, non-invasive, in vivo biodosimetry. Our preliminary data show an excellent correlation between predicted signal amplitude and delivered dose. With further development, a robust means of predicting delivered radiation dose from EPR measurements is expected. This project was funded by the Biomedical Advanced Research and Development Authority (BARDA) within the U.S. Department of Health and Human Services subcontracted through the Geisel School of Medicine at Dartmouth and by the Dartmouth Physically-Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR) Pilot Program.

60 APPLIED LIFE SCIENCES↗

Tomography of atomic number and density of materials using dual-energy imaging and the Alvarez and Macovski attenuation model

Dual-energy computed tomography and the Alvarez and Macovski [Phys. Med. Biol. 21, 733 (1976)] transmitted intensity (AMTI) model were used in this study to estimate the maps of density (ρ) and atomic number (Z) of mineralogical samples. In this method, the attenuation coefficients are represented [Alvarez and Macovski, Phys. Med. Biol. 21, 733 (1976)] in the form of the two most important interactions of X-rays with atoms that is, photoelectric absorption (PE) and Compton scattering (CS). This enables material discrimination as PE and CS are, respectively, dependent on the atomic number (Z) and density (ρ) of materials [Alvarez and Macovski, Phys. Med. Biol. 21, 733 (1976)]. Dual-energy imaging is able to identify sample materials even if the materials have similar attenuation coefficients at single-energy spectrum. We use the full model rather than applying one of several applied simplified forms [Alvarez and Macovski, Phys. Med. Biol. 21, 733 (1976); Siddiqui et al., SPE Annual Technical Conference and Exhibition (Society of Petroleum Engineers, 2004); Derzhi, U.S. patent application 13/527,660 (2012); Heismann et al., J. Appl. Phys. 94, 2073–2079 (2003); Park and Kim, J. Korean Phys. Soc. 59, 2709 (2011); Abudurexiti et al., Radiol. Phys. Technol. 3, 127–135 (2010); and Kaewkhao et al., J. Quant. Spectrosc. Radiat. Transfer 109, 1260–1265 (2008)]. This paper describes the tomographic reconstruction of ρ and Z maps of mineralogical samples using the AMTI model. The full model requires precise knowledge of the X-ray energy spectra and calibration of PE and CS constants and exponents of atomic number and energy that were estimated based on fits to simulations and calibration measurements. The estimated ρ and Z images of the samples used in this paper yield average relative errors of 2.62% and 1.19% and maximum relative errors of 2.64% and 7.85%, respectively. Furthermore, we demonstrate that the method accounts for the beam hardening effect in density (ρ) and atomic number (Z) reconstructions to a significant extent.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large area CMOS active pixel sensor x-ray imager for digital breast tomosynthesis: Analysis, modeling, and characterization

Purpose: Large area x-ray imagers based on complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology have been proposed for various medical imaging applications including digital breast tomosynthesis (DBT). The low electronic noise (50–300 e{sup −}) of CMOS APS x-ray imagers provides a possible route to shrink the pixel pitch to smaller than 75 μm for microcalcification detection and possible reduction of the DBT mean glandular dose (MGD). Methods: In this study, imaging performance of a large area (29 × 23 cm{sup 2}) CMOS APS x-ray imager [Dexela 2923 MAM (PerkinElmer, London)] with a pixel pitch of 75 μm was characterized and modeled. The authors developed a cascaded system model for CMOS APS x-ray imagers using both a broadband x-ray radiation and monochromatic synchrotron radiation. The experimental data including modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE) were theoretically described using the proposed cascaded system model with satisfactory consistency to experimental results. Both high full well and low full well (LFW) modes of the Dexela 2923 MAM CMOS APS x-ray imager were characterized and modeled. The cascaded system analysis results were further used to extract the contrast-to-noise ratio (CNR) for microcalcifications with sizes of 165–400 μm at various MGDs. The impact of electronic noise on CNR was also evaluated. Results: The LFW mode shows better DQE at low air kerma (K{sub a} < 10 μGy) and should be used for DBT. At current DBT applications, air kerma (K{sub a} ∼ 10 μGy, broadband radiation of 28 kVp), DQE of more than 0.7 and ∼0.3 was achieved using the LFW mode at spatial frequency of 0.5 line pairs per millimeter (lp/mm) and Nyquist frequency ∼6.7 lp/mm, respectively. It is shown that microcalcifications of 165–400 μm in size can be resolved using a MGD range of 0.3–1 mGy, respectively. In comparison to a General Electric GEN2 prototype DBT system (at MGD of 2.5 mGy), an increased CNR (by ∼10) for microcalcifications was observed using the Dexela 2923 MAM CMOS APS x-ray imager at a lower MGD (2.0 mGy). Conclusions: The Dexela 2923 MAM CMOS APS x-ray imager is capable to achieve a high imaging performance at spatial frequencies up to 6.7 lp/mm. Microcalcifications of 165 μm are distinguishable based on reported data and their modeling results due to the small pixel pitch of 75 μm. At the same time, potential dose reduction is expected using the studied CMOS APS x-ray imager.

60 APPLIED LIFE SCIENCES↗

Looking around: 35 years of oculomotor modeling

Eye movements have attracted an unusually large number of researchers from many disparate fields, especially over the past 35 years. The lure of this system stemmed from its apparent simplicity of description, measurement, and analysis, as well as the promise of providing a "window in the mind." Investigators in areas ranging from biological control systems and neurological diagnosis to applications in advertising and flight simulation expected eye movements to provide clear indicators of what the sensory-motor system was accomplishing and what the brain found to be of interest. The parallels between compensatory eye movements and perception of spatial orientation have been a subject for active study in visual-vestibular interaction, where substantial knowledge has accumulated through experiments largely guided by the challenge of proving or disproving model predictions. Even though oculomotor control has arguably benefited more from systems theory than any other branch of motor control, many of the original goals remain largely unfulfilled. This paper considers some of the promising potential benefits of eye movement research and compares accomplishments with anticipated results. Four topics are considered in greater detail: (i) the definition of oculomotor system input and output, (ii) optimization of the eye movement system, (iii) the relationship between compensatory eye movements and spatial orientation through the "internal model," and (iv) the significance of eye movements as measured in (outer) space.

Flight Experiment↗

Accuracy of Length of Virtual Stents in Treatment of Intracranial Wide-Necked Aneurysms

Background and Purpose: Precise stent deployment is important for successful treatment of intracranial aneurysms by stent-assisted coiling (SAC). We evaluated the accuracy of virtual stents generated using commercial stent planning software by comparing the length of virtual and actually deployed intracranial laser cut stents on three-dimensional digital subtraction angiography (3D-DSA) images. Methods: We retrospectively analyzed the data of 75 consecutive cases of intracranial wide-necked aneurysms treated with the SAC technique using laser cut stents. Based on 3D-DSA images acquired by C-arm CT, stent sizing and placement were intraoperatively simulated by a commercial software application. The difference in length of the stents was estimated by measuring proximal discrepancies between the end points of the virtual and actually deployed stents on fused pre-procedural and post-procedural 3D-DSA images. Discrepancies between distal stent end points were manually minimized. The Kruskal–Wallis test was applied to test whether stent location, type, and length had an effect on difference in length between virtual and real stent. Results: The median difference in length between virtual and real stents was 1.58 mm with interquartile range 1.12–2.12 mm. There was no evidence for an effect of stent location (p = 0.23), stent type (p = 0.33), or stent length (p = 0.53) on difference in length between virtual and real stents. Conclusions: Stent planning software allows 3D simulation of laser cut stents overlain on 3D-DSA images of vessels and may thus be useful for stent selection and deployment of laser cut stents during stent-assisted coiling of intracranial aneurysms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Distinguishing Recurrent Tumor From Radiation Necrosis: DWI and MTC in a Gamma Knife–Irradiated Mouse Glioma Model

Purpose: Accurate noninvasive diagnosis is vital for effective treatment planning. Presently, standard anatomical magnetic resonance imaging (MRI) is incapable of differentiating recurring tumor from delayed radiation injury, as both lesions are hyperintense in both postcontrast T1- and T2-weighted images. Further studies are therefore necessary to identify an MRI paradigm that can differentially diagnose these pathologies. Mouse glioma and radiation injury models provide a powerful platform for this purpose. Methods and Materials: Two MRI contrasts that are widely used in the clinic were chosen for application to a glioma/radiation-injury model: diffusion weighted imaging, from which the apparent diffusion coefficient (ADC) is obtained, and magnetization transfer contrast, from which the magnetization transfer ratio (MTR) is obtained. These metrics were evaluated longitudinally, first in each lesion type alone–glioma versus irradiation – and then in a combined irradiated glioma model. Results: MTR was found to be consistently decreased in all lesions compared to nonlesion brain tissue (contralateral hemisphere), with limited specificity between lesion types. In contrast, ADC, though less sensitive to the presence of pathology, was increased in radiation injury and decreased in tumors. In the irradiated glioma model, ADC also increased immediately after irradiation, but decreased as the tumor regrew. Conclusions: ADC is a better metric than MTR for differentiating glioma from radiation injury. However, MTR was more sensitive to both tumor and radiation injury than ADC, suggesting a possible role in detecting lesions that do not enhance strongly on T1-weighted images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Report: Reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data

Purpose: Accurate data regarding linear accelerator (Linac) radiation characteristics are important for treatment planning system modeling as well as regular quality assurance of the machine. The Imaging and Radiation Oncology Core-Houston (IROC-H) has measured the dosimetric characteristics of numerous machines through their on-site dosimetry review protocols. Photon data are presented and can be used as a secondary check of acquired values, as a means to verify commissioning a new machine, or in preparation for an IROC-H site visit. Methods: Photon data from IROC-H on-site reviews from 2000 to 2014 were compiled and analyzed. Specifically, data from approximately 500 Varian machines were analyzed. Each dataset consisted of point measurements of several dosimetric parameters at various locations in a water phantom to assess the percentage depth dose, jaw output factors, multileaf collimator small field output factors, off-axis factors, and wedge factors. The data were analyzed by energy and parameter, with similarly performing machine models being assimilated into classes. Common statistical metrics are presented for each machine class. Measurement data were compared against other reference data where applicable. Results: Distributions of the parameter data were shown to be robust and derive from a student’s t distribution. Based on statistical and clinical criteria, all machine models were able to be classified into two or three classes for each energy, except for 6 MV for which there were eight classes. Quantitative analysis of the measurements for 6, 10, 15, and 18 MV photon beams is presented for each parameter; supplementary material has also been made available which contains further statistical information. Conclusions: IROC-H has collected numerous data on Varian Linacs and the results of photon measurements from the past 15 years are presented. The data can be used as a comparison check of a physicist’s acquired values. Acquired values that are well outside the expected distribution should be verified by the physicist to identify whether the measurements are valid. Comparison of values to this reference data provides a redundant check to help prevent gross dosimetric treatment errors.

60 APPLIED LIFE SCIENCES↗

INCREASING THE TRANSPARENCY AND REPRODUCIBILITY OF SPACE RADIATION SCIENCE: THE RADIATION BIOLOGY ONTOLOGY

Among the primary objectives of the Open/Open-Source Science paradigm are making scientific investigation data transparent and results reproducible [1], objectives shared by the FAIR principles [2]. To accomplish this, the conceptual framework that includes all the investigation objects needs to be accurately captured and communicated to all data consumers. A large part of this requires using metadata standards to annotate data collected. These standards should be readily accessible, informed by scientific community consensus and sufficiently specific to encompass all of the important aspects of the investigation. Starting in 2020 we have been co-leading an open consortium to develop a new metadata standard, the Radiation Biology Ontology (RBO), through the Open Biological and Biomedical Ontologies (OBO) Foundry [3]. We began by transforming many of the terms from the National Council on Radiation Protection and Measurement into concepts that can be formally related to existing OBO Foundry classes or attributes. We then identified and imported into the RBO existing OBO Foundry classes that have obvious relevance for radiation biomedicine (for example, concepts from the Environment Ontology that describe radiative processes, and concepts from the Gene Ontology dealing with molecular and cellular responses to radiation). Finally, we scrutinized datasets from investigations of radiation effects held in NASA GeneLab and LSDA repositories and added additional classes, instances, and attributes into the RBO that should be used to annotate these data. We developed the RBO using the open-source tools of GitHub and publish the RBO periodically through the NIH/NCBI BioPortal website, so systems worldwide can leverage the knowledge it contains [4]. This initial phase of concept modeling has yielded an RBO that at present has more than 300 declared concepts, with more than 3500 additional concepts imported from other OBO Foundry ontologies. While this first phase has focused on concepts for annotating samples, environments, exposures, and measurements, the next phase will center on supporting annotation of results and findings, such as concept models of molecular, cellular and tissue effects. The value of the RBO will be determined in part by our ability to engage the community in its development, and we have established a Radiobiology Informatics Consortium with unrestricted membership as the owner of the RBO in order to encourage investigators, system owners and other to join in this effort. Anyone can report issues or request new concept modeling or other features directly on GitHub. By using the BioPortal application programming interface, systems can pose dynamic queries to the latest version of the RBO for information on individual classes or entire hierarchies; this design eliminates the need for systems to be updated in order to use newer versions of the RBO. We hope to contribute to the advancement of open radiobiological science through the continued, open development of the RBO, that will provide more precise, machine-interpretable descriptions of investigations, as well as support data meta-analysis through machine learning or other artificial intelligence methods.

knowledge↗