Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

SU-E-I-07: Response Characteristics and Signal Conversion Modeling of KV Flat-Panel Detector in Cone Beam CT System

Purpose: The flat-panel detector response characteristics are investigated to optimize the scanning parameter considering the image quality and less radiation dose. The signal conversion model is also established to predict the tumor shape and physical thickness changes. Methods: With the ELEKTA XVI system, the planar images of 10cm water phantom were obtained under different image acquisition conditions, including tube voltage, electric current, exposure time and frames. The averaged responses of square area in center were analyzed using Origin8.0. The response characteristics for each scanning parameter were depicted by different fitting types. The transmission measured for 10cm water was compared to Monte Carlo simulation. Using the quadratic calibration method, a series of variable-thickness water phantoms images were acquired to derive the signal conversion model. A 20cm wedge water phantom with 2cm step thickness was used to verify the model. At last, the stability and reproducibility of the model were explored during a four week period. Results: The gray values of image center all decreased with the increase of different image acquisition parameter presets. The fitting types adopted were linear fitting, quadratic polynomial fitting, Gauss fitting and logarithmic fitting with the fitting R-Square 0.992, 0.995, 0.997 and 0.996 respectively. For 10cm water phantom, the transmission measured showed better uniformity than Monte Carlo simulation. The wedge phantom experiment show that the radiological thickness changes prediction error was in the range of (-4mm, 5mm). The signal conversion model remained consistent over a period of four weeks. Conclusion: The flat-panel response decrease with the increase of different scanning parameters. The preferred scanning parameter combination was 100kV, 10mA, 10ms, 15frames. It is suggested that the signal conversion model could effectively be used for tumor shape change and radiological thickness prediction. Supported by National Natural Science Foundation of China (81101132, 11305203) and Natural Science Foundation of Anhui Province (11040606Q55, 1308085QH138)

60 APPLIED LIFE SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the One Earth Energy Well #1 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize the Lower Mt. Simon Sandstone and Eau Claire Formation core from the One Earth Energy Well #1 (OEE Well #1) in the Illinois Basin. The primary impetus of this work is a collaboration between the U.S. Department of Energy (DOE), the Illinois State Geological Survey (ISGS), the University of Illinois, and One Earth Energy to characterize and make publicly available core information of interest to carbon sequestration efforts in the Illinois Basin. This stratigraphic well and the core data produced in this report will aid in understanding the carbon sequestration potential of the Lower Mt. Simon Sandstone and the sealing capacity of the overlying units. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/illinois-storage-corridor-one-earth-energy-1-core.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Whipkey ST 1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Formation from a vertical well drilled in Greene County, Pennsylvania by the Energy Corporation of America. The core is from the Whipkey ST 1 well, in the Carmichaels Field, and is comprised primarily of the Marcellus Formation from depths of 7,719 to 7,910.8 ft. Core was provided by Tim Carr and Keithan Martin (West Virginia University and ORISE). The primary impetus of this work is a collaboration between West Virginia University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica Shale Formations. As part of this effort, bulk scans of core were obtained from the Whipkey ST 1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/whipkey-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

DECT evaluation of noncalcified coronary artery plaque

Purpose: Composition of the coronary artery plaque is known to have critical role in heart attack. While calcified plaque can easily be diagnosed by conventional CT, it fails to distinguish between fibrous and lipid rich plaques. In the present paper, the authors discuss the experimental techniques and obtain a numerical algorithm by which the electron density (ρ{sub e}) and the effective atomic number (Z{sub eff}) can be obtained from the dual energy computed tomography (DECT) data. The idea is to use this inversion method to characterize and distinguish between the lipid and fibrous coronary artery plaques. Methods: For the purpose of calibration of the CT machine, the authors prepare aqueous samples whose calculated values of (ρ{sub e}, Z{sub eff}) lie in the range of (2.65 × 10{sup 23} ≤ ρ{sub e} ≤ 3.64 × 10{sup 23}/cm{sup 3}) and (6.80 ≤ Z{sub eff} ≤ 8.90). The authors fill the phantom with these known samples and experimentally determine HU(V{sub 1}) and HU(V{sub 2}), with V{sub 1},V{sub 2} = 100 and 140 kVp, for the same pixels and thus determine the coefficients of inversion that allow us to determine (ρ{sub e}, Z{sub eff}) from the DECT data. The HU(100) and HU(140) for the coronary artery plaque are obtained by filling the channel of the coronary artery with a viscous solution of methyl cellulose in water, containing 2% contrast. These (ρ{sub e}, Z{sub eff}) values of the coronary artery plaque are used for their characterization on the basis of theoretical models of atomic compositions of the plaque materials. These results are compared with histopathological report. Results: The authors find that the calibration gives ρ{sub e} with an accuracy of ±3.5% while Z{sub eff} is found within ±1% of the actual value, the confidence being 95%. The HU(100) and HU(140) are found to be considerably different for the same plaque at the same position and there is a linear trend between these two HU values. It is noted that pure lipid type plaques are practically nonexistent, and microcalcification, as observed in histopathology, has to be taken into account to explain the nature of the observed (ρ{sub e}, Z{sub eff}) data. This also enables us to judge the composition of the plaque in terms of basic model which considers the plaque to be composed of fibres, lipids, and microcalcification. Conclusions: This simple and reliable method has the potential as an effective modality to investigate the composition of noncalcified coronary artery plaques and thus help in their characterization. In this inversion method, (ρ{sub e}, Z{sub eff}) of the scanned sample can be found by eliminating the effects of the CT machine and also by ensuring that the determination of the two unknowns (ρ{sub e}, Z{sub eff}) does not interfere with each other and the nature of the plaque can be identified in terms of a three component model.

60 APPLIED LIFE SCIENCES↗

A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis

Purpose: In radiotherapy based only on magnetic resonance imaging (MRI), knowledge about tissue electron densities must be derived from the MRI. This can be achieved by converting the MRI scan to the so-called pseudo-computed tomography (pCT). An obstacle is that the voxel intensities in conventional MRI scans are not uniquely related to electron density. The authors previously demonstrated that a patch-based method could produce accurate pCTs of the brain using conventional T{sub 1}-weighted MRI scans. The method was driven mainly by local patch similarities and relied on simple affine registrations between an atlas database of the co-registered MRI/CT scan pairs and the MRI scan to be converted. In this study, the authors investigate the applicability of the patch-based approach in the pelvis. This region is challenging for a method based on local similarities due to the greater inter-patient variation. The authors benchmark the method against a baseline pCT strategy where all voxels inside the body contour are assigned a water-equivalent bulk density. Furthermore, the authors implement a parallelized approximate patch search strategy to speed up the pCT generation time to a more clinically relevant level. Methods: The data consisted of CT and T{sub 1}-weighted MRI scans of 10 prostate patients. pCTs were generated using an approximate patch search algorithm in a leave-one-out fashion and compared with the CT using frequently described metrics such as the voxel-wise mean absolute error (MAE{sub vox}) and the deviation in water-equivalent path lengths. Furthermore, the dosimetric accuracy was tested for a volumetric modulated arc therapy plan using dose–volume histogram (DVH) point deviations and γ-index analysis. Results: The patch-based approach had an average MAE{sub vox} of 54 HU; median deviations of less than 0.4% in relevant DVH points and a γ-index pass rate of 0.97 using a 1%/1 mm criterion. The patch-based approach showed a significantly better performance than the baseline water pCT in almost all metrics. The approximate patch search strategy was 70x faster than a brute-force search, with an average prediction time of 20.8 min. Conclusions: The authors showed that a patch-based method based on affine registrations and T{sub 1}-weighted MRI could generate accurate pCTs of the pelvis. The main source of differences between pCT and CT was positional changes of air pockets and body outline.

60 APPLIED LIFE SCIENCES↗

SU-E-J-224: Using UTE and T1 Weighted Spin Echo Pulse Sequences for MR-Only Treatment Planning; Phantom Study

Purpose: Investigating a new approach in MRI based treatment planning using the combination of (Ultrashort Echo Time) UTE and T1 weighted spin echo pulse sequences to delineate air, bone and water (soft tissues) in generating pseudo CT images comparable with CT. Methods: A gel phantom containing chicken bones, ping pang balls filled with distilled water and air bubbles, was made. It scanned with MRI using UTE and 2D T1W SE pulse sequences with (in plane resolution= 0.53mm, slice thickness= 2 mm) and CT with (in plane resolution= 0.5 mm and slice thickness= 0.75mm) as a ground truth for geometrical accuracy. The UTE and T1W SE images were registered with CT using mutual information registration algorithm provided by Philips Pinnacle treatment planning system. The phantom boundaries were detected using Canny edge detection algorithm for CT, and MR images. The bone, air bubbles and water in ping pong balls were segmented from CT images using threshold 300HU, - 950HU and 0HU, respectively. These tissue inserts were automatically segmented from combined UTE and T1W SE images using edge detection and relative intensity histograms of the phantom. The obtained segmentations of air, bone and water inserts were evaluated with those obtained from CT. Results: Bone and air can be clearly differentiated in UTE images comparable to CT. Combining UTE and T1W SE images successfully segmented the air, bone and water. The maximum segmentation differences from combine MRI images (UTE and T1W SE) and CT are within 1.3 mm, 1.1mm for bone, air, respectively. The geometric distortion of UTE sequence is small less than 1 pixel (0.53 mm) of MR image resolution. Conclusion: Our approach indicates that MRI can be used solely for treatment planning and its quality is comparable with CT.

60 APPLIED LIFE SCIENCES↗

TU-F-12A-05: Sensitivity of Textural Features to 3D Vs. 4D FDG-PET/CT Imaging in NSCLC Patients

Purpose: Neighborhood Gray-level difference matrices (NGLDM) based texture parameters extracted from conventional (3D) 18F-FDG PET scans in patients with NSCLC have been previously shown to associate with response to chemoradiation and poorer patient outcome. However, the change in these parameters when utilizing respiratory-correlated (4D) FDG-PET scans has not yet been characterized for NSCLC. The Objectives: of this study was to assess the extent to which NGLDM-based texture parameters on 4D PET images vary with reference to values derived from 3D scans in NSCLC. Methods: Eight patients with newly diagnosed NSCLC treated with concomitant chemoradiotherapy were included in this study. 4D PET scans were reconstructed with OSEM-IR in 5 respiratory phase-binned images and corresponding CT data of each phase were employed for attenuation correction. NGLDM-based texture features, consisting of coarseness, contrast, busyness, complexity and strength, were evaluated for gross tumor volumes defined on 3D/4D PET scans by radiation oncologists. Variation of the obtained texture parameters over the respiratory cycle were examined with respect to values extracted from 3D scans. Results: Differences between texture parameters derived from 4D scans at different respiratory phases and those extracted from 3D scans ranged from −30% to 13% for coarseness, −12% to 40% for contrast, −5% to 50% for busyness, −7% to 38% for complexity, and −43% to 20% for strength. Furthermore, no evident correlations were observed between respiratory phase and 4D scan texture parameters. Conclusion: Results of the current study showed that NGLDM-based texture parameters varied considerably based on choice of 3D PET and 4D PET reconstruction of NSCLC patient images, indicating that standardized image acquisition and analysis protocols need to be established for clinical studies, especially multicenter clinical trials, intending to validate prognostic values of texture features for NSCLC.

60 APPLIED LIFE SCIENCES↗

Comparison of three measurement modalities for 3D characterization of manufactured features and process-induced porosity in titanium alloy additively manufactured parts

Nondestructive characterization of internal features and defects within complex components is vital for many industrial applications, particularly with the advent of additive manufacturing (AM) technologies. However, community understanding of the limitations of nondestructive methods such as X-ray Computed Tomography (CT) can be limited in certain industrial sectors as these may be emergent applications. In this paper, we investigate the limits of X-ray CT measurements and compare extracted data with mechanical polishing serial sectioning (MPSS) and confocal laser scanning microscopy (CLSM). The test object is an additively manufactured titanium alloy disk that contains both process-induced porosity and machined features, including focused ion beam milled features designed to probe the resolution limits of X-ray CT. Results show that each of these characterization techniques has advantages and disadvantages. We compare data acquisition times, spatial resolution, geometric measurement accuracy and defect visualization fidelity across these modalities to establish a practical framework.

Additive manufacturing↗

Computed Tomography Scanning and Geophysical Measurements of the Smackover Formation from the Roberson 18-19 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize the Upper Jurassic (Oxfordian) Smackover limestone in the Roberson 18-19 1-15H core retrieved from the Atlanta Field, Columbia County, Arkansas. The 365.68-ft long Roberson core came from a vertical well at depths 8,802 ft to 9,169.60 ft, drilled by Southwestern Energy targeting the Smackover Formation as a potential unconventional oil reservoir. The primary impetus of this work was to non-destructively characterize core from the Smackover Formation that was acquired through a core exchange with Southwestern Energy. The Smackover Formation is an unconventional limestone play in southern Arkansas. This report and the associated scans provide detailed datasets not typically made publicly available from unconventional limestone for analysis. The resultant datasets are presented in this report and can be accessed from NETL’s Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/roberson-smackover.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of Core from the Marcellus Shale Energy and Environment Laboratory

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize middle Devonian black shale from the Marcellus Shale Energy and Environmental Laboratory (MSEEL) site in northeastern West Virginia. The samples are representative of the Middle Devonian Marcellus Formation, a clay-rich black shale in the Appalachian Basin. The MSEEL site is a unique field study area for new techniques supporting natural gas production and a high level of monitoring of environmental impacts. The primary impetus of this work is a collaboration between NETL, West Virginia University, Northeast Natural Energy (NNE), and Ohio State University to characterize core from multiple wells to better understand the structure and variation of the Marcellus Shale formations. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis.

58 GEOSCIENCES↗

TU-F-18C-07: Hardware Advances for MTF Improvement in Dedicated Breast CT

Purpose: In this study, we have designed and implemented a prototype dedicated breast CT system (bCT) to improve the spatial resolution characteristics, in order to improve detection of micro-calcifications. Methods: A 10.8 kW water-cooled, tungsten anode x-ray tube, running up to 240 mA at 60 kV, coupled with an x-ray generator specifically designed for this application, and 0.3 mm of added copper filter was used to generate x-ray pulses. A CsI CMOS flat panel detector with a pixel pitch of 0.075 mm in native binning mode was used. The system geometry was designed in a way to achieve an FOV on par with similar bCT prototypes, resulting in a magnification factor of 1.39. A 0.013 mm tungsten wire was used to generate point spread functions. Multiple scans were performed with different numbers of projections, different reconstruction kernel sizes and different reconstruction filters to study the effects of each parameter on MTF. The resulting MTFs were then evaluated quantitatively using the generated PFSs. Duplicate scans with the same parameters were performed on two other dedicated breast CT systems to compare the performance of the new prototype. Results: The results of the MTF experiments demonstrate a significant improvement in the spatial resolution characteristics. In the new prototype, using the pulsed x-ray source results in a restoration of the azimuthal MTF degradation, due to motion blurring previously seen in other bCT systems. Moreover, employing the higher resolution x-ray detector considerably improves the MTF. The MTF at 10% of the new system is at 3.5 1/mm, a factor of 4.36 greater than an earlier bCT scanner. Conclusion: The MTF analysis of the new prototype bCT shows that using the new hardware and control results in a significant improvement in visualization of finer detail. This suggests that the visualization of micro-calcifications will be significantly improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of Error in Maximal Intensity Projection-Based Internal Target Volume of Lung Tumors: A Simulation and Comparison Study Using Dynamic Magnetic Resonance Imaging

Purpose: To evaluate the error in four-dimensional computed tomography (4D-CT) maximal intensity projection (MIP)-based lung tumor internal target volume determination using a simulation method based on dynamic magnetic resonance imaging (dMRI). Methods and Materials: Eight healthy volunteers and six lung tumor patients underwent a 5-min MRI scan in the sagittal plane to acquire dynamic images of lung motion. A MATLAB program was written to generate re-sorted dMRI using 4D-CT acquisition methods (RedCAM) by segmenting and rebinning the MRI scans. The maximal intensity projection images were generated from RedCAM and dMRI, and the errors in the MIP-based internal target area (ITA) from RedCAM ({epsilon}), compared with those from dMRI, were determined and correlated with the subjects' respiratory variability ({nu}). Results: Maximal intensity projection-based ITAs from RedCAM were comparatively smaller than those from dMRI in both phantom studies ({epsilon} = -21.64% {+-} 8.23%) and lung tumor patient studies ({epsilon} = -20.31% {+-} 11.36%). The errors in MIP-based ITA from RedCAM correlated linearly ({epsilon} = -5.13{nu} - 6.71, r{sup 2} = 0.76) with the subjects' respiratory variability. Conclusions: Because of the low temporal resolution and retrospective re-sorting, 4D-CT might not accurately depict the excursion of a moving tumor. Using a 4D-CT MIP image to define the internal target volume might therefore cause underdosing and an increased risk of subsequent treatment failure. Patient-specific respiratory variability might also be a useful predictor of the 4D-CT-induced error in MIP-based internal target volume determination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Fidelity Microstructural Characterization and Performance Modeling of Aluminized Composite Propellant

Image processing and stereological techniques were used to characterize the heterogeneity of composite propellant and inform a predictive burn rate model. Composite propellant samples made up of ammonium perchlorate (AP), hydroxyl-terminated polybutadiene (HTPB), and aluminum (Al) were faced with an ion mill and imaged with a scanning electron microscope (SEM) and x-ray tomography (micro-CT). Properties of both the bulk and individual components of the composite propellant were determined from a variety of image processing tools. An algebraic model, based on the improved Beckstead-Derr-Price model developed by Cohen and Strand, was used to predict the steady-state burning of the aluminized composite propellant. In the presented model the presence of aluminum particles within the propellant was introduced. The thermal effects of aluminum particles are accounted for at the solid-gas propellant surface interface and aluminum combustion is considered in the gas phase using a single global reaction. In conclusion, properties derived from image processing were used directly as model inputs, leading to a sample-specific predictive combustion model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorine-18-Labeled Fluoromisonidazole Positron Emission and Computed Tomography-Guided Intensity-Modulated Radiotherapy for Head and Neck Cancer: A Feasibility Study

Purpose: Hypoxia renders tumor cells radioresistant, limiting locoregional control from radiotherapy (RT). Intensity-modulated RT (IMRT) allows for targeting of the gross tumor volume (GTV) and can potentially deliver a greater dose to hypoxic subvolumes (GTV{sub h}) while sparing normal tissues. A Monte Carlo model has shown that boosting the GTV{sub h} increases the tumor control probability. This study examined the feasibility of fluorine-18-labeled fluoromisonidazole positron emission tomography/computed tomography ({sup 18}F-FMISO PET/CT)-guided IMRT with the goal of maximally escalating the dose to radioresistant hypoxic zones in a cohort of head and neck cancer (HNC) patients. Methods and Materials: {sup 18}F-FMISO was administered intravenously for PET imaging. The CT simulation, fluorodeoxyglucose PET/CT, and {sup 18}F-FMISO PET/CT scans were co-registered using the same immobilization methods. The tumor boundaries were defined by clinical examination and available imaging studies, including fluorodeoxyglucose PET/CT. Regions of elevated {sup 18}F-FMISO uptake within the fluorodeoxyglucose PET/CT GTV were targeted for an IMRT boost. Additional targets and/or normal structures were contoured or transferred to treatment planning to generate {sup 18}F-FMISO PET/CT-guided IMRT plans. Results: The heterogeneous distribution of {sup 18}F-FMISO within the GTV demonstrated variable levels of hypoxia within the tumor. Plans directed at performing {sup 18}F-FMISO PET/CT-guided IMRT for 10 HNC patients achieved 84 Gy to the GTV{sub h} and 70 Gy to the GTV, without exceeding the normal tissue tolerance. We also attempted to deliver 105 Gy to the GTV{sub h} for 2 patients and were successful in 1, with normal tissue sparing. Conclusion: It was feasible to dose escalate the GTV{sub h} to 84 Gy in all 10 patients and in 1 patient to 105 Gy without exceeding the normal tissue tolerance. This information has provided important data for subsequent hypoxia-guided IMRT trials with the goal of further improving locoregional control in HNC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Biomaterials Using Micro-Computerized Tomography

Micro-computed tomography or Micro-CT is a high resolution, non-invasive, x-ray scanning technique that allows precise three-dimensional imaging and quantification of micro-architectural and structural parameters of objects. Tomographic reconstruction is based on a cone-beam convolution-back-projection algorithm. Micro-architectural and structural parameters such as porosity, surface area to volume ratio, interconnectivity, pore size, wall thickness, anisotropy and cross-section area of biomaterials and bio-specimens such as trabecular bone, polymer scaffold, bio-ceramics and dental restorative were evaluated through imaging and computer aided manipulation of the object scan data sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The management of tumor motions in the stereotactic irradiation to lung cancer under the use of Abches to control active breathing

Purpose: Breathing control is crucial to ensuring the accuracy of stereotactic irradiation for lung cancer. This study monitored respiration in patients with inoperable nonsmall-cell lung cancer using a respiration-monitoring apparatus, Abches, and investigated the reproducibility of tumor position in these patients. Methods: Subjects comprised 32 patients with nonsmall-cell lung cancer who were administered stereotactic radiotherapy under breath-holding conditions monitored by Abches. Computed tomography (CT) was performed under breath-holding conditions using Abches (Abches scan) for treatment planning. A free-breathing scan was performed to determine the range of tumor motions in a given position. After the free-breathing scan, Abches scan was repeated and the tumor position thus defined was taken as the intrafraction tumor position. Abches scan was also performed just before treatment, and the tumor position thus defined was taken as the interfraction tumor position. To calculate the errors, tumor positions were compared based on Abches scan for the initial treatment plan. The error in tumor position was measured using the BrainSCAN treatment-planning device, then compared for each lung lobe. Results: Displacements in tumor position were calculated in three dimensions (i.e., superior-inferior (S-I), left-right (L-R), and anterior-posterior (A-P) dimensions) and recorded as absolute values. For the whole lung, average intrafraction tumor displacement was 1.1 mm (L-R), 1.9 mm (A-P), and 2.0 mm (S-I); the average interfraction tumor displacement was 1.1 mm (L-R), 2.1 mm (A-P), and 2.0 mm (S-I); and the average free-breathing tumor displacement was 2.3 mm (L-R), 3.5 mm (A-P), and 7.9 mm (S-I). The difference between using Abches and free breathing could be reduced from approximately 20 mm at the maximum to approximately 3 mm in the S-I direction for both intrafraction and interfraction positions in the lower lobe. In addition, maximum intrafraction tumor displacement with the use of Abches was 4.5 mm (S-I) in the lingular segment. These results suggest that use of the Abches system can reduce deviations in tumor position to levels below those achieved under free breathing, irrespective of the tumor location. Conclusions: Respiratory control with high accuracy and reproducibility is required for high-precision radiotherapy of inoperable nonsmall-cell lung cancer and was achieved using Abches in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-19: A New End-To-End Test Method for ExacTrac for Radiation and Plan Isocenter Congruence

Purpose: To combine and integrate quality assurance (QA) of target localization and radiation isocenter End to End (E2E) test of BrainLAB ExacTrac system, a new QA approach was devised using anthropomorphic head and neck phantom. This test insures the target localization as well as radiation isocenter congruence which is one step ahead the current ExacTrac QA procedures. Methods: The head and neck phantom typically used for CyberKnife E2E test was irradiated to the sphere target that was visible in CT-sim images. The CT-sim was performed using 1 mm thickness slice with helical scanning technique. The size of the sphere was 3-cm diameter and contoured as a target volume using iPlan V.4.5.2. A conformal arc plan was generated using MLC-based with 7 fields, and five of them were include couch rotations. The prescription dose was 5 Gy and 95% coverage to the target volume. For the irradiation, two Gafchromic films were perpendicularly inserted into the cube that hold sphere inside. The linac used for the irradiation was TrueBeam STx equipped with HD120 MLC. In order to use ExacTrac, infra-red head–array was used to correlate orthogonal X-ray images. Results: Using orthogonal X-rays of ExacTrac the phantom was positioned. For each field, phantom was check again with X-rays and re-positioned if necessary. After each setup using ExacTrac, the target was irradiated. The films were analyzed to determine the deviation of the radiation isocenter in all three dimensions: superior-inferior, left-right and anterior-posterior. The total combining error was found to be 0.76 mm ± 0.05 mm which was within sub-millimeter accuracy. Conclusion: Until now, E2E test for ExacTrac was separately implemented to test image localization and radiation isocenter. This new method can be used for periodic QA procedures.

60 APPLIED LIFE SCIENCES↗

WE-A-17A-10: Fast, Automatic and Accurate Catheter Reconstruction in HDR Brachytherapy Using An Electromagnetic 3D Tracking System

Purpose: In high dose rate brachytherapy (HDR-B), actual catheter reconstruction protocols are slow and errors prompt. The purpose of this study was to evaluate the accuracy and robustness of an electromagnetic (EM) tracking system for improved catheter reconstruction in HDR-B protocols. Methods: For this proof-of-principle, a total of 10 catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a Philips-design 18G biopsy needle (used as an EM stylet) and the second generation Aurora Planar Field Generator from Northern Digital Inc. The Aurora EM system exploits alternating current technology and generates 3D points at 40 Hz. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical CT system with a resolution of 0.089 mm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, 5 catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 seconds or less. This would imply that for a typical clinical implant of 17 catheters, the total reconstruction time would be less than 3 minutes. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.92 ± 0.37 mm and 1.74 ± 1.39 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be significantly more accurate (unpaired t-test, p < 0.05). A mean difference of less than 0.5 mm was found between successive EM reconstructions. Conclusion: The EM reconstruction was found to be faster, more accurate and more robust than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators. We would like to disclose that the equipments, used in this study, is coming from a collaboration with Philips Medical.

07 ISOTOPE AND RADIATION SOURCES↗