Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Impact of Meteorological Factors on the Mesoscale Morphology of Cloud Streets during a Cold-Air Outbreak over the Western North Atlantic

We report postfrontal clouds (PFC) are ubiquitous in the marine boundary layer, and their morphology is essential to estimating the radiation budget in weather and climate models. Here we examine the roles of sea surface temperature (SST) and meteorological factors in controlling the mesoscale morphology and evolution of shallow clouds associated with a cold-air outbreak that occurred on 1 March 2020 during phase I of the Aerosol Cloud Meteorology Interactions over the Western Atlantic Experiment (ACTIVATE). Our results show that the simulated PFC structure and ambient conditions by the Weather Research and Forecasting (WRF) Model are generally consistent with observations from GOES-16 and dropsonde measurements. We also examine the thermodynamical and dynamical influences in the cloud mesoscale morphology using WRF sensitivity experiments driven by two meteorological forcing datasets with different domain-mean SST and spatial gradients, which lead to dissimilar values of hydrometeor water path and cloud core fraction. The SST from ERA5 leads to weaker stability and higher inversion height than the SST from FNL does. In addition, the use of large-scale meteorological forcings from ERA5 yields a distinctive time evolution of wind direction shear in the inner domain, which favors the formation and persistence of longer cloud rolls. Both factors contribute to a change in the time evolution of domain-mean water path and cloud core fraction of cloud streets. Our study takes advantage of the simulation driven by the differences between two large-scale forcing datasets to illustrate the importance of SST and wind direction shear in the cloud street morphology in a realistic scenario.

54 ENVIRONMENTAL SCIENCES↗

Increased Quasi Stationarity and Persistence of Winter Ural Blocking and Eurasian Extreme Cold Events in Response to Arctic Warming. Part II: A Theoretical Explanation

In Part I of this study, it was shown that the Eurasian cold anomalies related to Arctic warming depend strongly on the quasi stationarity and persistence of the Ural blocking (UB). The analysis here revealed that under weak mean westerly wind (MWW) and vertical shear (VS) (quasi barotropic) conditions with weak synoptic-scale eddies and a large planetary wave anomaly, the growth of UB is slow and its amplitude is small. For this case, a quasi-stationary and persistent UB is seen. However, under strong MWW and VS (quasi baroclinic) conditions, synoptic-scale eddies are stronger and the growth of UB is rapid; the resulting UB is less persistent and has large amplitude. In this case, a marked retrogression of the UB is observed. The dynamical mechanism behind the dependence of the movement and persistence of UB upon the background conditions is further examined using a nonlinear multiscale model. The results show that when the blocking has large amplitude under quasi-baroclinic conditions, the blocking-induced westward displacement greatly exceeds the strong mean zonal-wind-induced eastward movement and hence generates a marked retrogression of the blocking. By contrast, under quasi-barotropic conditions because the UB amplitude is relatively small the blocking-induced westward movement is less distinct, giving rise to a quasi-stationary and persistent blocking. It is further shown that the strong mid–high-latitude North Atlantic mean zonal wind is the quasi-barotropic condition that suppresses UB’s retrogression and thus is conducive to the quasi stationarity and persistence of the UB. The model results show that the blocking duration is longer when the mean zonal wind in the blocking region or eddy strength is weaker.

54 ENVIRONMENTAL SCIENCES↗

Cold-Season Precipitation Sensitivity to Microphysical Parameterizations: Hydrologic Evaluations Leveraging Snow Lidar Datasets

Abstract Cloud microphysical processes are an important facet of atmospheric modeling, as they can control the initiation and rates of snowfall. Thus, parameterizations of these processes have important implications for modeling seasonal snow accumulation. We conduct experiments with the Weather Research and Forecasting (WRF V4.3.3) Model using three different microphysics parameterizations, including a sophisticated new scheme (ISHMAEL). Simulations are conducted for two cold seasons (2018 and 2019) centered on the Colorado Rockies’ ∼750-km 2 East River watershed. Precipitation efficiencies are quantified using a drying-ratio mass budget approach and point evaluations are performed against three NRCS SNOTEL stations. Precipitation and meteorological outputs from each are used to force a land surface model (Noah-MP) so that peak snow accumulation can be compared against airborne snow lidar products. We find that microphysical parameterization choice alone has a modest impact on total precipitation on the order of ±3% watershed-wide, and as high as 15% for certain regions, similar to other studies comparing the same parameterizations. Precipitation biases evaluated against SNOTEL are 15% ± 13%. WRF Noah-MP configurations produced snow water equivalents with good correlations with airborne lidar products at a 1-km spatial resolution: Pearson’s r values of 0.9, RMSEs between 8 and 17 cm, and percent biases of 3%–15%. Noah-MP with precipitation from the PRISM geostatistical precipitation product leads to a peak SWE underestimation of 32% in both years examined, and a weaker spatial correlation than the WRF configurations. We fall short of identifying a clearly superior microphysical parameterization but conclude that snow lidar is a valuable nontraditional indicator of model performance.

54 ENVIRONMENTAL SCIENCES↗

Modeling the Evolution and Life Cycle of Stable Cold Pools

Stable cold pools in California’s Central Valley (CV) are conducive to freezing temperatures, high relative humidity, and, in some cases, fog. Here, it will be shown that the Weather Research and Forecasting (WRF) Model as commonly configured cannot reproduce such conditions because of a persistent warm and dry bias near the surface. It was discovered that removing horizontal diffusion, which by default operates on model levels and thus up and down the valley’s sides, can reduce but not entirely fix the problem. Further improvements include enhancing the near-surface vertical resolution and the surface–air coupling, as both directly control the surface fluxes, especially evaporation. Yet, these alterations actually have the largest impact in the forested region surrounding the Central Valley, and influence the nighttime relative humidity in the CV only indirectly via nocturnal drainage flows. While it is not clear how realistic are the increased evaporation in the forest or the drainage flows, how and why these alterations result in significantly improved relative humidity reconstructions within the Central Valley are shown.

54 ENVIRONMENTAL SCIENCES↗

Linear system identification of a cold flow circulating fluidized bed

Knowledge of the solids circulation rate (SCR) is essential to the control and improved performance of a circulating fluidized bed system. In the present work, the noise model is derived using the prediction error method considering process and measurement noises acting on the cold flow circulating fluidized bed (CFCFB) with a cork particulate material. The outputs of the initial model are the total pressure drop across the riser, the pressure drop across the crossover, the pressure drop across the primary cyclone, the total pressure drop across the stand-pipe, the pressure drop across the loop seal, and the SCR. The stochastic estimate of SCR is determined from the noise model using the stochastic pressure drop estimates. The deterministic estimate is obtained through the inputs taken as move air flow, riser aeration, and loop seal fluidization air that are all independent variables of the given setup and under the control of the user. The theory has been developed to convert a complete blackbox model to a grey box model through the output-to-state transformation such that both the models of the CFCFB consists of all these output variables as the states of the system, and only pressure drops across the system as the output measurements. Thus, the final models do not include any fictitious terms and they are defined only in terms of physical parameters of the given system. Both components of SCR are separately analysed. The combined SCR response of both the noise model and deterministic model is compared with the validation data set of this state variable in terms of modelfit, and the results are shown.

42 ENGINEERING↗

Interference between Raman gain and four-wave mixing in cold atoms

Using a pump-probe scheme with a large cloud of cold rubidium atoms, we observe very large double-pass gain (1800%) due to interference between Raman gain and four-wave mixing. A simple model explains the main features observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of alloying elements, cold work, and hydrogen on the irradiation-induced growth behavior of zirconium alloy variants - 2016-0040

In-reactor dimensional changes in zirconium-based alloys result from a complex interplay of many factors, such as (1) alloy type and composition, including the addition of elements such as niobium, iron, and tin; (2) fabrication process, including cold work, texture, and residual stresses; (3) irradiation temperature; and (4) hydrogen levels. In many cases, the observed dimensional changes in light water reactor fuel-assembly components-especially at high exposures-cannot be fully explained based on current growth and creep models. Therefore, a systematic approach was taken in this multi-year (2005-2011) Nuclear Fuel Industry Research Program investigation. The objective was to measure stress-free irradiation-induced growth (IIG) of specially fabricated alloys through irradiation under controlled conditions in the BOR-60 fast-flux test reactor up to a high fluence of approximately 2X10{sup 26} m{sup -2} (E>1 MeV)-equivalent to maximum of approximately 37 dpa exposure-followed by postirradiation examinations (PIEs). Irradiation temperature was within a narrow temperature range (320±10 deg. C). The PIEs included dimensional-change and microhardness measurements, metallography and hydride etching, and scanning transmission electron microscopy (STEM) or transmission electron microscopy (TEM). All irradiation samples (typically flat rectangular coupons or curvilinear cutouts of cladding tubes sized 35 by 6.5 by 0.8 mm) were pre-filmed to avoid the uptake of impurity hydrogen from sodium-cooled BOR-60. A wide variety of samples representing standard LWR cladding alloys with and without pre-hydriding (approximately 116 to approximately 718 ppm) as well as special compositions with iron contents (100 to 4,000 ppm) were irradiated. The irradiation in BOR-60 was done in five different stages (eight micro-cycles) and lasted approximately 18 months with interim and final growth measurements made using a high precision-length measurement device. Results of the extensive investigation include: significant effects of Fe, Nb, and hydrogen additions; quantification of growth rates from low to very high fluences (dpas); measurement of volume changes; and correlation of growth with -component dislocation densities. (authors)

36 MATERIALS SCIENCE↗

Demonstration of the Hygrothermal Performance of a Next-Generation Insulation Material in a Cold Climate

Energy loss through building walls is estimated to cost the department of defense (DOD) about $200m/year, accounting for 5% of the total energy cost in DOD facilities. This article describes the demonstration of a high-performance insulation material, called modified atmosphere insulation (MAI), to reduce wall-related heat losses in a DOD building located in Ft. Drum, New York, in a cold climate. MAI has been demonstrated to achieve R32/inch (hr-ft2-°F/Btu-in) or greater and its use can significantly increase the thermal resistance of walls with a marginal increase in wall thickness, making it an ideal candidate for retrofit application. MAI is a variant of vacuum insulation panels (VIP), produced at a substantially reduced cost resulting from a change in the evacuation process.By retrofitting walls and increasing thermal resistance, as measured by R-value, by R10-20 (h-ft2-°F/Btu), reductions of 30% or more over baseline wall-generated space conditioning loads are possible. Further, with targeted applications for older or more poorly insulated facilities, greater energy savings can be achieved. In this article, the installation of MAI panels in an existing building at Ft. Drum and the resulting energy benefits will be described. Like VIPs, MAI panels consist of an evacuated nanoporous core that is encapsulated within air and vapor impermeable barrier films. Addition of these impermeable barrier films can have implications on the moisture storage and movement within the wall systems. Therefore, in addition to the thermal performance evaluation, measurements and modeling will be used to determine the hygric behavior of the retrofitted walls.

Biswas, Kaushik↗

Binder-free cold spray deposition of NdFeB permanent magnets

Cold spray deposition is employed to manufacture binder-free Nd 2 Fe 14 B permanent magnets. Millimeter thick deposits can be fabricated in seconds on substrates such as glass or copper. The Nd 2 Fe 14 B particles appear to partially embed in the substrate and interlock with one another, building up a dense layer that is consolidated by subsequent impacts. The impact and subsequent heating of the particles leads to formation of a magnetically soft phase that significantly reduces coercivity, X-ray diffraction identifies it as Fe. Furthermore, this can be mitigated by reducing gas velocity and temperature, leading to a partial retention of magnetic properties.

36 MATERIALS SCIENCE↗

DEMONSTRATION OF TWICE REDUCED LORENTZ FORCE DETUNING IN SRF CAVITY BY COPPER COLD SPRAYING

Superconducting RF (SRF) cavities usually are made of thin-wall high RRR Niobium that is susceptible to Lorentz Force Detuning (LFD) ? cavity deformation phenomena caused by high magnitude RF fields. This type of deformation can be mitigated by using an additional copper layer deposited on the outer surface of the cavity. In this paper, we present both modeling results and experimental data of high gradient test of an SRF cavity at cryogenic temperatures. It was demonstrated that LFD can be significantly reduced (factor of two) by the copper cold spray reinforcement without sacrificing cavity flexibility for tuning. We also present a finite-element model that allows us to confirm our experimental results and optimize the cavity geometry for LFD reduction with incorporated coupled RF, structural and thermal modules.

Kostin, R.↗

Electrical and Thermal Properties of Cold-Sprayed Bulk Copper and Copper-Tungsten Samples at Cryogenic Temperatures

The de­vel­op­ment of high ther­mal con­duc­tiv­ity coat­ings with pure cop­per or cop­per-tung­sten alloy could be ben­e­fi­cial to im­prove the heat trans­fer of bulk Nb cav­i­ties for con­duc­tion cool­ing ap­pli­ca­tions and to in­crease the stiff­ness of bulk Nb cav­i­ties cooled by liq­uid he­lium. Cold-spray is an ad­di­tive man­u­fac­tur­ing tech­nique suit­able to grow thick coat­ings of ei­ther Cu or CuW on a Nb sub­strate. Bulk (~5 mm thick) coat­ings of Cu and CuW were de­posited on stan­dard 3 mm thick, high-pu­rity Nb sam­ples and smaller sam­ples with 2 mm x 2 mm cross sec­tion were cut for mea­sur­ing the ther­mal con­duc­tiv­ity and the resid­ual re­sis­tiv­ity ratio. The sam­ples were sub­jected to an­neal­ing at dif­fer­ent tem­per­a­tures and a max­i­mum RRR of ~130 and ~40 were mea­sured for the Cu sam­ples and CuW sam­ples, re­spec­tively.

Pokhrel, H.↗

Strategy Guideline: Energy Retrofits for Low-Rise Multifamily Buildings in Cold Climates

This Strategy Guideline explains the benefits of evaluating and identifying energy efficiency retrofit measures that could be made during renovation and maintenance of multifamily buildings. It focuses on low-rise multifamily structures (three or fewer stories) in a cold climate. These benefits lie primarily in reduced energy use, lower operating and maintenance costs, improved durability of the structure, and increased occupant comfort. This guideline focuses on retrofit measures for roof repair or replacement, exterior wall repair or gut rehab, and eating system maintenance. All buildings are assumed to have a flat ceiling and a trussed roof, wood- or steel-framed exterior walls, and one or more single or staged boilers. Estimated energy savings realized from the retrofits will vary, depending on the size and condition of the building, the extent of efficiency improvements, the efficiency of the heating equipment, the cost and type of fuel, and the climate location.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance House -- A Cold Climate Challenge Home

Working with builder partners on a test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, CARB partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, CT. The philosophy and science behind the 2,700 ft2 'Performance House' was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the 'Performance House' were not cutting-edge, but simply 'best practices practiced'. The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 IECC code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. To help builders and architects seeking to match the performance of this home, a step-by-step guide through the building shell components of DOE's Challenge Home are provided in a pictorial story book. The end result was a DOE Challenge Home that achieved a HERS Index Score of 20 (43 without PV, the minimum target was 55 for compliance). This home was also awarded the 2012 HOBI for Best Green Energy Efficient Home from the Home Builders & Remodelers Association of Connecticut.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IEA HPP Annex 41 Cold Climate Heat Pumps: Task 1 Report Literature and Technology Review United States - ORNL/TM-2013/472

During the mid-1970s, following the first oil embargo, heat pumps became of great interest to northern U. S. electric power companies, particularly for those experiencing large peak demands during the heating season, as shortages of natural gas and oil led to increased usage of direct electric heating. Air-source heat pumps (ASHP), given their wider market presence relative to other heat pump types, almost universal applicability, and inherent efficiency and capacity issues at cold outdoor temperatures were of primary interest as an electrical heating system alternative at that time. ASHPs based on the simple vapor compression cycle suffer both heating capacity (output) and efficiency (coefficient of performance or COP) degradation as the outdoor ambient temperature drops.

Baxter, Van D.↗

Performance House: A Cold Climate Challenge Home, Old Greenwich, Connecticut (Fact Sheet)

By working with builder partners on test homes, researchers from the U.S. Department of Energy's Building America program can vet whole-house building strategies and avoid potential unintended consequences of implementing untested solution packages on a production scale. To support this research, Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 "Performance House" was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adaptable to the needs of homeowners. The technologies and strategies used in the "Performance House" were best practices rather than cutting edge, with a focus on simplicity in construction, maintenance, and operation. Achieving 30% source energy savings compared with a home built to the 2009 International Energy Conservation Code in the cold climate zone requires that nearly all components and systems be optimized. Careful planning and design are critical. The end result was a DOE Challenge Home that achieved a Home Energy Rating System (HERS) Index Score of 20 (43 without photovoltaics [PV]).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fission Product Separation from Pyrochemical Electrolyte by Cold Finger Melt Crystallization

This work contributes to the development of pyroprocessing technology as an economically viable means of separating used nuclear fuel from fission products and cladding materials. Electrolytic oxide reduction is used as a head-end step before electrorefining to reduce oxide fuel to metallic form. The electrolytic medium used in this technique is molten LiCl-Li2O. Groups I and II fission products, such as cesium (Cs) and strontium (Sr), have been shown to partition from the fuel into the molten LiCl-Li2O. Various approaches of separating these fission products from the salt have been investigated by different research groups. One promising approach is based on a layer crystallization method studied at the Korea Atomic Energy Research Institute (KAERI). Despite successful demonstration of this basic approach, there are questions that remain, especially concerning the development of economical and scalable operating parameters based on a comprehensive understanding of heat and mass transfer. This research explores these parameters through a series of experiments in which LiCl is purified, by concentrating CsCl in a liquid phase as purified LiCl is crystallized and removed via an argon-cooled cold finger.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗