Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Locating the Source of Events in Power Distribution Systems Using Micro-PMU Data

A novel method is proposed to locate the source of events in power distribution systems by using distribution-level phasor measurement units, a.k.a., micro-PMUs. An event in this paper is defined rather broadly to include any major change in any component across the distribution feeder. The goal is to enhance situational awareness in distribution grid by keeping track of the operation (or misoperation) of various grid equipment, assets, distribution energy resources, loads, etc. The proposed method is built upon the compensation theorem in circuit theory to generate an equivalent circuit to represent the event by using voltage and current synchrophasors that are captured by micro-PMUs. Importantly, this method makes critical use of not only magnitude but also synchronized phase angle measurements, thus, it justifies the need to use micro-PMUs, as opposed to ordinary RMS-based voltage and current sensors. The proposed method can work with data from as a few as only two micro-PMUs. The effectiveness of the developed method is demonstrated through computer simulations on the IEEE 123-bus test system, and also on micro-PMUs measurements from a real-life 12.47 kV test feeder in Riverside, CA. In conclusion, the results verify that the proposed method is accurate and robust in locating the source of different types of events on power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmission of Images With Ultrasonic Elastic Shear Waves on a Metallic Pipe Using Amplitude Shift Keying Protocol

Transmission of information using ultrasonic elastic waves on existing metallic pipes provides an alternative communication option across physical barriers in a highly partitioned industrial complex, such as a nuclear facility. This work investigates the feasibility of the transmission of digital images over metallic pipes. Ultrasonic communication systems for transmission of images on a nuclear-grade stainless steel pipe were assembled for bench-scale demonstration. Information carriers in this system are refracted shear waves transmitted and received with piezoelectric transducers (PZTs) operating at 2-MHz nominal frequency. The refraction and propagation of ultrasonic shear waves were modeled with COMSOL software. An amplitude shift keying (ASK) communication protocol for image transmission was developed and implemented in the GNURadio software-defined radio (SDR) environment. Digital information was converted to analog ultrasonic signals using Red Pitaya electronic boards. The performance of the ASK protocol is evaluated at the output of every block in the GNURadio program by monitoring the transmission of select characters. Using the ASK communication protocol, the transmission of the 32-KB image was demonstrated at 2-Kbps bitrate across 6-ft-long stainless steel pipe. Finally, preliminary evaluation of ultrasonic communication on the piping of a nuclear facility, such as signal transmission on bent pipes, was performed with COMSOL computer simulations.

42 ENGINEERING↗

Metabolic network reconstruction and flux variability analysis of storage synthesis in developing oilseed rape (Brassica napus L.) embryos

Computational simulation of large-scale biochemical networks can be used to analyze and predict the metabolic behavior of an organism, such as a developing seed. Based on the biochemical literature, pathways databases and decision rules defining reaction directionality we reconstructed bna572, a stoichiometric metabolic network model representing Brassica napus seed storage metabolism. In the highly compartmentalized network about 25% of the 572 reactions are transport reactions interconnecting nine subcellular compartments and the environment. According to known physiological capabilities of developing B. napus embryos, four nutritional conditions were defined to simulate heterotrophy or photoheterotrophy, each in combination with the availability of inorganic nitrogen (ammonia, nitrate) or amino acids as nitrogen sources. Based on mathematical linear optimization the optimal solution space was comprehensively explored by flux variability analysis, thereby identifying for each reaction the range of flux values allowable under optimality. The range and variability of flux values was then categorized into flux variability types. Across the four nutritional conditions, approximately 13% of the reactions have variable flux values and 10-11% are substitutable (can be inactive), both indicating metabolic redundancy given, for example, by isoenzymes, subcellular compartmentalization or the presence of alternative pathways. About one-third of the reactions are never used and are associated with pathways that are suboptimal for storage synthesis. Fifty-seven reactions change flux variability type among the different nutritional conditions, indicating their function in metabolic adjustments. This predictive modeling framework allows analysis and quantitative exploration of storage metabolism of a developing B. napus oilseed.

59 BASIC BIOLOGICAL SCIENCES↗

A Novel Method for Preoperative Positioning of Total Ankle Replacement Using 3D Digital Model

Abstract Objective To establish a digital model of the ankle joint through 3D imaging technology and explore the preoperative placement of ankle replacement prostheses. Methods Computed tomography images of intact ankle joints from 54 cases in the outpatient and inpatient departments of our hospital were collected; according to the INBONE® total ankle system surgery process, the surgery model and surgical osteotomy were finished using MIMICS based on computer simulation method. The shortest distance was measured between the center point and the anterior, posterior, medial, and lateral, respectively, to ensure the precise position of the ankle replacement prosthesis by digital simulation surgery. The relationship between the two variables was analyzed by bivariate correlation analysis. Results The dataset of this study included 48 cases of the sub‐data set (26 males and 22 females) and included 27 cases of left ankle and 21 cases of right ankle. The average medial malleolar angle was 18.67°± 2.87°, the average amount of bone resection was 12.13 ± 1.86 cm 3 , the mid‐anterior distance was 1.72 ± 0.19 cm, the mid‐posterior distance was 2.00 ± 0.19 cm, the ratio of mid‐anterior to mid‐posterior was 0.87, the mid‐medial distance was 1.26 ± 0.17 cm, the mid‐lateral distance was 1.19 ± 0.16 cm, and the ratio of mid‐medial to mid‐lateral was 1.06. After osteotomy, the anteroposterior diameter was 3.73 ± 0.32 cm, the transverse diameter was 2.46 ± 0.27 cm, and the ratio of anteroposterior diameter to transverse diameter was 1.53. In the bottom view, the shape after osteotomy is rectangular. The mid‐anterior distance was strongly negatively correlated with age, the mid‐anterior distance and the amount of bone resection, the mid‐medial distance and the amount of bone resection, the mid‐lateral distance and the amount of bone resection, the mid‐lateral distance and the anteroposterior diameter, the anteroposterior diameter and the transverse diameter were all strongly positively correlated. Conclusion The projection point of the lower tibia centerline on the tibial horizontal osteotomy surface is located at a position slightly anterior to the midpoint of the transverse diameter after ankle arthroplasty. The rational positioning of the total ankle replacement is located at both a position slightly anterior to the midpoint of the transverse diameter and midpoint of the anteroposterior diameter, which can be used as a reference method before total ankle arthroplasty surgery.

Wu, Shi‐xun↗

General Correlations for Laminar Flow Friction Loss and Heat Transfer in Plain Rectangular Plate-Fin Cores

In this paper, new generalized correlations for predicting the average fanning friction factor f and average Nusselt number Nu for laminar flow in plain plate-fin compact cores of rectangular cross section are presented. These are based on extended experimental data, as well as three-dimensional computational simulations, obtained for a broad range of fin density and geometrical attributes. The results indicate that while the fully developed forced convection scales only with the interfin channel cross-sectional ratio α (fin spacing by fin height), the entrance region hydrodynamic and thermal performance is additionally a function of the fin-core length L, flow Reynolds number Re, and fluid Prandtl number Pr. The developing flow and convection is further shown to scale as: (fRe)~(L/d h Re) 1/2 , and Nu ~(L/d h Re) 1/2 Pr 1/3 Φ(α), where f, Re, and Nu are all based on the hydraulic diameter dh of the interfin flow channel. Generalized correlations for both (fRe) and Nu are developed by the corresponding scaling of the forced convection behavior and asymptotic matching of the entrance or developing flow (short fin-core flow length) and the fully developed flow (large fin-core flow length) region performance. Finally, the predictions from these correlations are found to be within ±15% of all available experimental data for air, water, and glycol (0.71 ≤ Pr ≤ 10), and fin cores with 0 < α ≤ 1.

36 MATERIALS SCIENCE↗

Developing Uncertainty Quantification Strategies in Electromagnetic Problems Involving Highly Resonant Cavities

High-quality factor resonant cavities are challenging structures to model in electromagnetics owing to their large sensitivity to minute parameter changes. Therefore, uncertainty quantification (UQ) strategies are pivotal to understanding key parameters affecting the cavity response. Furthermore, we discuss here some of these strategies focusing on shielding effectiveness (SE) properties of a canonical slotted cylindrical cavity that will be used to develop credibility evidence in support of predictions made using computational simulations for this application.

47 OTHER INSTRUMENTATION↗

Role of Three-Dimensional Swirl in Forced Convection Heat Transfer Enhancement in Wavy-Plate-Fin Channels

The influence of wall-corrugation-induced swirl flow on enhanced forced convection in wavy-plate-fin cores has been investigated. Three-dimensional computational simulations were carried out for steady-state periodically developed air flow (Pr ~ 0.71; 50 ≤ Re ≤ 4000) with channel walls subject to constant-uniform temperature conditions. The recirculation that develops in the wall troughs and grows to have an axially helical character is scaled by the Swirl number Sw. As Sw increases with higher flowrate and/or corrugation severity, tornado-shaped vortices appear in the wave trough region midway of the interfin channel height, then extend longitudinally to encompass majority of the flow channel. The local wall-shear and heat transfer coefficient variations indicate that boundary-layer thinning upstream of the wave peak aids in intensifying momentum and heat transfer. However, the flow recirculation in wall trough impedes heat transfer at low Sw due to flow stagnation but promotes it at high Sw because of the vortices-induced augmented fluid mixing. The effects of this secondary flow are quantified by Φf(or j), which is seen to increase log-linearly as fin corrugation aspect ratio γ and/or fin spacing ratio ζ increases; the influence of cross section aspect ratio α is marginal. Moreover, the pressure drag penalty due to swirl critically affects overall pressure loss, and its proportion remains nearly constant when α varies, but grows as Sw, γ, and/or ζ increases and can be as much as 80% of the total pressure drop.

Engineering↗

Ion optical effects in a low pressure rf plasma

Ion optical effects in low pressure gas discharges are introduced as a novel input into low pressure plasma technology. They are based on appropriate geometrical plasma confinements which enable a control of the shape of internal density and potential distributions and, hence, the ion motion in the plasma bulk. Such effects are exemplified for an electron cyclotron wave resonance plasma in Ar at 1–5 × 10{sup −3} millibars. The geometry of the plasma chamber is modified by a conical and a cylindrical insert. Computer simulations display spherical plasma density contours to be formed around the conical confinement. This effects an increase of the ratio of the ion currents into the conical and the cylindrical inserts which depends on the fourth power of the plasma electron temperature. A quantitative understanding of this behavior is presented. As another essential result, the shape of the internal plasma contours is found to be independent of the pressure controlled plasma parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-scale theory-assisted nano-engineering of plasmonic-organic hybrid electro-optic device performance

Multi-scale (correlated quantum and statistical mechanics) modeling methods have been advanced and employed to guide the improvement of organic electro-optic (OEO) materials, including by analyzing electric field poling induced electro-optic activity in nanoscopic plasmonic-organic hybrid (POH) waveguide devices. The analysis of in-device electro-optic activity emphasizes the importance of considering both the details of intermolecular interactions within organic electro-optic materials and interactions at interfaces between OEO materials and device architectures. Dramatic improvement in electro-optic device performance--including voltage-length performance, bandwidth, energy efficiency, and lower optical losses have been realized. These improvements are critical to applications in telecommunications, computing, sensor technology, and metrology. Multi-scale modeling methods illustrate the complexity of improving the electro-optic activity of organic materials, including the necessity of considering the trade-off between improving poling-induced acentric order through chromophore modification and the reduction of chromophore number density associated with such modification. Computational simulations also emphasize the importance of developing chromophore modifications that serve multiple purposes including matrix hardening for enhanced thermal and photochemical stability, control of matrix dimensionality, influence on material viscoelasticity, improvement of chromophore molecular hyperpolarizability, control of material dielectric permittivity and index of refraction properties, and control of material conductance. Consideration of new device architectures is critical to the implementation of chipscale integration of electronics and photonics and achieving the high bandwidths for applications such as next generation (e.g., 5G) telecommunications.

Engineering↗

Accurate quantification of width and density of bone structures by computed tomography

In computed tomography (CT), the representation of edges between objects of different densities is influenced by the limited spatial resolution of the scanner. This results in the misrepresentation of density of narrow objects, leading to errors of up to 70% and more. Our interest is in the imaging and measurement of narrow bone structures, and the issues are the same for imaging with clinical CT scanners, peripheral quantitative CT scanners or micro CT scanners. Mathematical models, phantoms and tests with patient data led to the following procedures: (i) extract density profiles at one-degree increments from the CT images at right angles to the bone boundary; (ii) consider the outer and inner edge of each profile separately due to different adjacent soft tissues; (iii) measure the width of each profile based on a threshold at fixed percentage of the difference between the soft-tissue value and a first approximated bone value; (iv) correct the underlying material density of bone for each profile based on the measured width with the help of the density-versus-width curve obtained from computer simulations and phantom measurements. This latter curve is specific to a certain scanner and is not dependent on the densities of the tissues within the range seen in patients. This procedure allows the calculation of the material density of bone. Based on phantom measurements, we estimate the density error to be below 2% relative to the density of normal bone and the bone-width error about one tenth of a pixel size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A short-scan reconstruction for cone-beam CT using shift-invariant FBP and equal weighting

A 3D reconstruction formula has been derived for a circular cone-beam (CB) short scan using 1D shift-invariant filtering, CB backprojection, and equal weighting. By first converting the divergent projections to parallel projections, we analyze the circular CB data using the classic central slice theorem. The sampling density in Fourier space is investigated and 1D shift-invariant filtering before backprojection can be used to compensate for the nonuniformity. The final formula consists of a conventional FDK reconstruction and a correction term using differential backprojection and the 1D Hilbert transform in the image domain. On a full scan, the approach reduces to the FDK algorithm, while for a short scan, the CB artifacts are suppressed by the second term. This algorithm outperforms the modified FDK algorithm with Parker's weighting, as illustrated by computer simulations and experimental results. Due to its shift-invariant filtered-backprojection structure, the proposed algorithm is implemented efficiently, and requires a simple adaptation of the FDK algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerating protons to therapeutic energies with ultraintense, ultraclean, and ultrashort laser pulses

Proton acceleration by high-intensity laser pulses from ultrathin foils for hadron therapy is discussed. With the improvement of the laser intensity contrast ratio to 10{sup -11} achieved on the Hercules laser at the University of Michigan, it became possible to attain laser-solid interactions at intensities up to 10{sup 22} W/cm{sup 2} that allows an efficient regime of laser-driven ion acceleration from submicron foils. Particle-in-cell (PIC) computer simulations of proton acceleration in the directed Coulomb explosion regime from ultrathin double-layer (heavy ions/light ions) foils of different thicknesses were performed under the anticipated experimental conditions for the Hercules laser with pulse energies from 3 to 15 J, pulse duration of 30 fs at full width half maximum (FWHM), focused to a spot size of 0.8 {mu}m (FWHM). In this regime heavy ions expand predominantly in the direction of laser pulse propagation enhancing the longitudinal charge separation electric field that accelerates light ions. The dependence of the maximum proton energy on the foil thickness has been found and the laser pulse characteristics have been matched with the thickness of the target to ensure the most efficient acceleration. Moreover, the proton spectrum demonstrates a peaked structure at high energies, which is required for radiation therapy. Two-dimensional PIC simulations show that a 150-500 TW laser pulse is able to accelerate protons up to 100-220 MeV energies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The noise power spectrum in CT with direct fan beam reconstruction

The noise power spectrum (NPS) is a useful metric for understanding the noise content in images. To examine some unique properties of the NPS of fan beam CT, the authors derived an analytical expression for the NPS of fan beam CT and validated it with computer simulations. The nonstationary noise behavior of fan beam CT was examined by analyzing local regions and the entire field-of-view (FOV). This was performed for cases with uniform as well as nonuniform noise across the detector cells and across views. The simulated NPS from the entire FOV and local regions showed good agreement with the analytically derived NPS. The analysis shows that whereas the NPS of a large FOV in parallel beam CT (using a ramp filter) is proportional to frequency, the NPS with direct fan beam FBP reconstruction shows a high frequency roll off. Even in small regions, the fan beam NPS can show a sharp transition (discontinuity) at high frequencies. These effects are due to the variable magnification and therefore are more pronounced as the fan angle increases. For cases with nonuniform noise, the NPS can show the directional dependence and additional effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel solid-angle tomosynthesis (SAT) scanning scheme

Purpose: Digital tomosynthesis (DTS) recently gained extensive research interests in both diagnostic and radiation therapy fields. Conventional DTS images are generated by scanning an x-ray source and flat-panel detector pair on opposite sides of an object, with the scanning trajectory on a one-dimensional curve. A novel tomosynthesis method named solid-angle tomosynthesis (SAT) is proposed, where the x-ray source scans on an arbitrary shaped two-dimensional surface. Methods: An iterative algorithm in the form of total variation regulated expectation maximization is developed for SAT image reconstruction. The feasibility and effectiveness of SAT is corroborated by computer simulation studies using three-dimensional (3D) numerical phantoms including a 3D Shepp-Logan phantom and a volumetric CT image set of a human breast. Results: SAT is able to cover more space in Fourier domain more uniformly than conventional DTS. Greater coverage and more isotropy in the frequency domain translate to fewer artifacts and more accurately restored features in the in-plane reconstruction. Conclusions: Comparing with conventional DTS, SAT allows cone-shaped x-ray beams to project from more solid angles, thus provides more coverage in the spatial-frequency domain, resulting in better quality of reconstructed image.

60 APPLIED LIFE SCIENCES↗

A generic, geometric cocalibration method for a combined system of fluorescence molecular tomography and microcomputed tomography with arbitrarily shaped objects

Purpose: A combined system of fluorescence molecular tomography and microcomputed tomography (FMT and mCT) can provide molecular and anatomical information of small animals in a single study with intrinsically coregistered images. The anatomical information provided by the mCT subsystem is commonly used as a reference to locate the fluorophore distribution or as a priori structural information to improve the performance of FMT. Therefore, the transformation between the coordinate systems of the subsystem needs to be determined in advanced. Methods: A cocalibration method for the combined system of FMT and mCT is proposed. First, linear models are adopted to describe the galvano mirrors and the charge-coupled device (CCD) camera in the FMT subsystem. Second, the position and orientation of the galvano mirrors are determined with the input voltages of the galvano mirrors and the markers, whose positions are predetermined. The position, orientation and normalized pixel size of the CCD camera are obtained by analysing the projections of a point-like marker at different positions. Finally, the orientation and position of sources and the corresponding relationship between the detectors and their projections on the image plane are predicted. Because the positions of the markers are acquired with mCT, the registration of the FMT and mCT could be realized by direct image fusion. Results: The accuracy and consistency of this method in the presence of noise is evaluated by computer simulation. Next, a practical implementation for an experimental FMT and mCT system is carried out and validated. The maximum prediction error of the source positions on the surface of a cylindrical phantom is within 0.375 mm and that of the projections of a point-like marker is within 0.629 pixel. Finally, imaging experiments of the fluorophore distribution in a cylindrical phantom and a phantom with a complex shape demonstrate the feasibility of the proposed method. Conclusions: This method is universal in FMT and mCT, which could be performed with no restriction on the system geometry, calibration phantoms or imaging objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model

Purpose: This research is designed to develop and evaluate a flat-panel detector-based dynamic cone beam CT system for dynamic angiography imaging, which is able to provide both dynamic functional information and dynamic anatomic information from one multirevolution cone beam CT scan. Methods: A dynamic cone beam CT scan acquired projections over four revolutions within a time window of 40 s after contrast agent injection through a femoral vein to cover the entire wash-in and wash-out phases. A dynamic cone beam CT reconstruction algorithm was utilized and a novel recovery method was developed to correct the time-enhancement curve of contrast flow. From the same data set, both projection-based subtraction and reconstruction-based subtraction approaches were utilized and compared to remove the background tissues and visualize the 3D vascular structure to provide the dynamic anatomic information. Results: Through computer simulations, the new recovery algorithm for dynamic time-enhancement curves was optimized and showed excellent accuracy to recover the actual contrast flow. Canine model experiments also indicated that the recovered time-enhancement curves from dynamic cone beam CT imaging agreed well with that of an IV-digital subtraction angiography (DSA) study. The dynamic vascular structures reconstructed using both projection-based subtraction and reconstruction-based subtraction were almost identical as the differences between them were comparable to the background noise level. At the enhancement peak, all the major carotid and cerebral arteries and the Circle of Willis could be clearly observed. Conclusions: The proposed dynamic cone beam CT approach can accurately recover the actual contrast flow, and dynamic anatomic imaging can be obtained with high isotropic 3D resolution. This approach is promising for diagnosis and treatment planning of vascular diseases and strokes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of hybrid depth scanning for carbon-ion radiotherapy

Purpose: In radiotherapy with a scanned carbon-ion beam, its Bragg peak is shifted along the depth direction either by inserting the range shifter plates or by changing the beam-extraction energy of a synchrotron. In the former technique (range shifter scanning: RS), the range shifter plates broaden the beam size and produce secondary fragments through nuclear reactions. In the latter technique (active-energy scanning: ES), it may take several seconds to change the beam energy depending on the synchrotron operation cycle, leading to a long treatment time. The authors propose a hybrid depth scan technique (hybrid scanning: HS), where several beam energies are used in conjunction with the range shifter plates for finer range shift. In this study, HS is evaluated from the viewpoints of dose distribution and treatment time. Methods: Assuming realistic accelerator and beam-delivery systems, the authors performed computer simulations using GEANT4 Monte Carlo code for beam modeling and a treatment planning system to evaluate HS. Three target volumes with the same dimensions of 60 x 60 x 60 mm{sup 3} were generated at depths of 45, 85, and 125 mm in water phantom, and uniform clinical dose was planned for these targets. The sizes of lateral dose falloff and the peak to plateau ratio defined as the ratio of the clinical dose averaged over the target to the clinical dose at the entrance as well as the treatment time were compared among the three depth scan techniques. Results: The sizes of lateral dose falloffs at the center of SOBP are 11.4, 8.5, and 5.9 mm for the three targets in RS, while they are 5.7, 4.8, and 4.6 mm in ES and 6.6, 5.7, and 5.0 mm in HS, respectively. The peak to plateau ratios are 1.39, 1.96, and 2.15 in RS, while they are 1.48, 2.04, and 2.19 in ES and 1.47, 2.03, and 2.18 in HS, respectively. The treatment times are 128.7, 128.6, and 128.6 s in ES, while they are 61.2, 54.6, and 47.8 s in RS and 43.2, 44.1, and 44.7 s in HS, respectively. The multiple scattering and the nuclear reaction by range shifter degraded the beam qualities such as lateral dose falloff and peak to plateau ratio, which was especially pronounced for the shallow target in RS. The depth scan timing was limited by accelerator cycle in ES. That increased the treatment time by a few times. Conclusions: This study revealed that HS can provide dose distributions with steeper lateral dose falloffs and higher peak to plateau ratio comparing to RS and comparable to ES. In addition, the treatment time can be considerably reduced in HS compared to ES.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗