Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Glow-to-arc transition events in H{sub 2}-Ar direct current pulsed plasma: Automated measurement of current and voltage

The glow-to-arc transition phenomena (arcing) observed in plasma reactors used in materials processing was studied through the arcs characteristic current and voltage waveforms. In order to capture these arcs signals, a LABVIEW based automated instrumentation system (ARCVIEW) was developed, including the integration of an oscilloscope equipped with proper current and voltage probes. The system also allows capturing the process parameters at the arc occurrence moments, which were used to map the arcs events conditions. Experiments in H{sub 2}-Ar DC pulsed plasma returned signals data from 215 arcs events, which were analyzed through software routines. According to the results, an anti-arcing system should react in the time order of few microseconds to prevent most of the damage caused by the undesired arcing phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a time-variable nuclear pulser for half life measurements

In this work a time-variable pulser system with an exponentially-decaying pulse frequency is presented, which was developed using the low-cost, open-source Arduino microcontroler plataform. In this system, the microcontroller produces a TTL signal in the selected rate and a pulse shaper board adjusts it to be entered in an amplifier as a conventional pulser signal; both the decay constant and the initial pulse rate can be adjusted using a user-friendly control software, and the pulse amplitude can be adjusted using a potentiometer in the pulse shaper board. The pulser was tested using several combinations of initial pulse rate and decay constant, and the results show that the system is stable and reliable, and is suitable to be used in half-life measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasonic wave-based structural health monitoring embedded instrument

Piezoelectric sensors and actuators are the bridge between electronic and mechanical systems in structures. This type of sensor is a key element in the integrity monitoring of aeronautic structures, bridges, pressure vessels, wind turbine blades, and gas pipelines. In this paper, an all-in-one system for Structural Health Monitoring (SHM) based on ultrasonic waves is presented, called Phased Array Monitoring for Enhanced Life Assessment. This integrated instrument is able to generate excitation signals that are sent through piezoelectric actuators, acquire the received signals in the piezoelectric sensors, and carry out signal processing to check the health of structures. To accomplish this task, the instrument uses a piezoelectric phased-array transducer that performs the actuation and sensing of the signals. The flexibility and strength of the instrument allow the user to develop and implement a substantial part of the SHM technique using Lamb waves. The entire system is controlled using configuration software and has been validated through functional, electrical loading, mechanical loading, and thermal loading resistance tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact focusing spectrometer: Visible (1 eV) to hard x-rays (200 keV)

A low-cost spectrometer that covers a wide range of photon energies can be useful to teach spectroscopy, and for simple, rapid measurements of the photon spectrum produced by small plasma devices. The spectrometer here achieves its wide range, nominally from 1 eV to 200 keV, with a series of spherically and cylindrically bent gratings or crystals that all have the same shape and the same radius of curvature; they are complemented by matching apertures and diagnostics on the Rowland circle that serves as the circular part of the spectrometer's vacuum vessel. Spectral lines are easily identified with software that finds their positions from the dispersion of each diffractive element and the known energies of the lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of high temporal resolution Thomson scattering data during a modulated electron cyclotron resonance heating using conditional averaging

This paper provides a software application of the sampling scope concept for fusion research. The time evolution of Thomson scattering data is reconstructed with a high temporal resolution during a modulated electron cyclotron resonance heating (MECH) phase. The amplitude profile and the delay time profile of the heat pulse propagation are obtained from the reconstructed signal for discharges having on-axis and off-axis MECH depositions. The results are found to be consistent with the MECH deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

57Fe Mössbauer isomer shift of pure iron and iron oxides at high pressure—An experimental and theoretical study

The 57Fe isomer shift (IS) of pure iron has been measured up to 100 GPa using synchrotron Mössbauer spectroscopy in the time domain. Apart from the expected discontinuity due to the α→ε structural and spin transitions, the IS decreases monotonically with increasing pressure. The absolute shifts were reproduced without semi-empirical calibrations by periodic density functional calculations employing extensive localized basis sets with several common density functionals. However, the best numerical agreement is obtained with the B1WC hybrid functional. Extension of the calculations to 350 GPa, a pressure corresponding to the Earth’s inner core, predicted the IS range of 0.00 to -0.85 mm/s, covering the span from Fe(0) to Fe(VI) compounds measured at ambient pressure. The calculations also reproduced the pressure trend from polymorphs of prototypical iron oxide minerals, FeO and Fe2O3. Analysis of the electronic structure shows a strong donation of electrons from oxygen to iron at high pressure. The assignment of formal oxidation to the Fe atom becomes ambiguous under this condition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the high energy engineering X-ray (HEX) superconducting wiggler, magnetic measurement, installation, and commissioning

The High energy Engineering X-ray (HEX) diffraction beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL) is the first high-energy beamline capable of reaching 200 keV for a monochromatic beam. With the 3 GeV electron beam energy for the NSLS-II ring, only the superconducting wiggler (SCW) producing greater than 4 T peak field can cover these ranges with a sufficient number of photons. The 1.2 m-long HEX-SCW has a period length of 70 mm and a field strength on-axis of 4.3 T. It utilizes no liquid helium, and the vertical aperture size of the electron beam vacuum chamber is 8 mm. Unlike regular undulators/wigglers, there is no standard configuration for the magnetic measurement system for superconducting insertion devices. The NSLS-II Insertion Devices group has developed, in collaboration with the vacuum group, a novel in-vacuum Hall mapper with a 1.75 m in-vacuum linear motor and an in-vacuum flip coil system utilizing many commercial-off-the-shelf products. The measurements were conducted at the BNL, and the device was installed in the ring and commissioned. Here, this paper provides a description of the SCW and its magnetic measurement systems, as well as a brief account of the installation and commissioning efforts.

36 MATERIALS SCIENCE↗

Extension of the possibilities of a commercial digital camera in detecting spatial intensity distribution of laser radiation

Performance capabilities of commercial digital cameras are demonstrated by the example of a Canon EOS 400D camera in measuring and detecting spatial distributions of laser radiation intensity. It is shown that software extraction of linear data expands the linear dynamic range of the camera by a factor greater than 10, up to 58 dB. Basic measurement characteristics of the camera are obtained in the regime of linear data extraction: the radiometric function, deviation from linearity, dynamic range, temporal and spatial noises (both dark and those depending on the signal value). The parameters obtained correspond to those of technical measuring cameras. (measurement of laser radiation parameters)

42 ENGINEERING↗

SU-E-J-126: Respiratory Gating Quality Assurance: A Simple Method to Achieve Millisecond Temporal Resolution

Purpose: Low temporal latency between a gating on/off signal and a linac beam on/off during respiratory gating is critical for patient safety. Although, a measurement of temporal lag is recommended by AAPM Task Group 142 for commissioning and annual quality assurance, there currently exists no published method. Here we describe a simple, inexpensive, and reliable method to precisely measure gating lag at millisecond resolutions. Methods: A Varian Real-time Position Management™ (RPM) gating simulator with rotating disk was modified with a resistive flex sensor (Spectra Symbol) attached to the gating box platform. A photon diode was placed at machine isocenter. Output signals of the flex sensor and diode were monitored with a multichannel oscilloscope (Tektronix™ DPO3014). Qualitative inspection of the gating window/beam on synchronicity were made by setting the linac to beam on/off at end-expiration, and the oscilloscope's temporal window to 100 ms to visually examine if the on/off timing was within the recommended 100-ms tolerance. Quantitative measurements were made by saving the signal traces and analyzing in MatLab™. The on and off of the beam signal were located and compared to the expected gating window (e.g. 40% to 60%). Four gating cycles were measured and compared. Results: On a Varian TrueBeam™ STx linac with RPM gating software, the average difference in synchronicity at beam on and off for four cycles was 14 ms (3 to 30 ms) and 11 ms (2 to 32 ms), respectively. For a Varian Clinac™ 21EX the average difference at beam on and off was 127 ms (122 to 133 ms) and 46 ms (42 to 49 ms), respectively. The uncertainty in the synchrony difference was estimated at ±6 ms. Conclusion: This new gating QA method is easy to implement and allows for fast qualitative inspection and quantitative measurements for commissioning and TG-142 annual QA measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-502: Biometrically Accepted Patient Records

Purpose: To implement a clinically useful palm vein pattern recognition biometric system to treat the correct treatment plan to the correct patient each and every time and to check-in the patient into the department to access the correct medical record. Methods: A commercially available hand vein scanning system was paired to Aria and utilized an ADT interface from the hospital electronic health system. Integration at two points in Aria, version 11 MR2, first at the appointment tracker screen for the front desk medical record access and second at the queue screen on the 4D treatment console took place for patient daily time-out. A test patient was utilized to check accuracy of identification as well as to check that no unintended interactions take place between the 4D treatment console and the hand vein scanning system. This system has been in clinical use since December 2013. Results: Since implementation, 445 patients have been enrolled into our biometric system. 95% of patients learn the correct methodology of hand placement on the scanner in the first try. We have had two instances of patient not found because of a bad initial scan. We simply erased the scanned metric and the patient enrolled again in those cases. The accuracy of the match is 100% for each patient, we have not had one patient misidentified. We can state this because we still use patient photo and date of birth as identifiers. A QA test patient is run monthly to check the integrity of the system. Conclusion: By utilizing palm vein scans along with the date of birth and patient photo, another means of patient identification now exits. This work indicates the successful implementation of technology in the area of patient safety by closing the gap of treating the wrong plan to a patient in radiation oncology. FOJP Service Corporation covered some of the costs of the hardware and software of the palm vein pattern recognition biometric system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vision 20/20: Simultaneous CT-MRI — Next chapter of multimodality imaging

Multimodality imaging systems such as positron emission tomography-computed tomography (PET-CT) and MRI-PET are widely available, but a simultaneous CT-MRI instrument has not been developed. Synergies between independent modalities, e.g., CT, MRI, and PET/SPECT can be realized with image registration, but such postprocessing suffers from registration errors that can be avoided with synchronized data acquisition. The clinical potential of simultaneous CT-MRI is significant, especially in cardiovascular and oncologic applications where studies of the vulnerable plaque, response to cancer therapy, and kinetic and dynamic mechanisms of targeted agents are limited by current imaging technologies. The rationale, feasibility, and realization of simultaneous CT-MRI are described in this perspective paper. The enabling technologies include interior tomography, unique gantry designs, open magnet and RF sequences, and source and detector adaptation. Based on the experience with PET-CT, PET-MRI, and MRI-LINAC instrumentation where hardware innovation and performance optimization were instrumental to construct commercial systems, the authors provide top-level concepts for simultaneous CT-MRI to meet clinical requirements and new challenges. Simultaneous CT-MRI fills a major gap of modality coupling and represents a key step toward the so-called “omnitomography” defined as the integration of all relevant imaging modalities for systems biology and precision medicine.

60 APPLIED LIFE SCIENCES↗

RUScal : Software for the analysis of resonant ultrasound spectroscopy measurements

Resonant ultrasound spectroscopy is used to nondestructively measure the elastic resonances of small solids to elucidate the material's elastic properties or other qualities like size, shape, or composition. In this work, we introduce the software RUScal for the purpose of determining elastic properties by analyzing the eigenfrequencies of solid specimens with common shapes, such as rectangular parallelepipeds, cylinders (solid and hollow tube), ellipsoids, and octahedrons, as well as irregularly shaped ellipsoids that can be described analytically. All symmetry classes are supported, from isotropic to triclinic, along with the option to add or remove up to three orthogonal mirror planes as well as the ability to reorient the crystal axes with respect the sample edges via Euler angles. Additional features include tools to help find initial sets of elastic constants, including grid exploration and Monte Carlo methods, a tool to analyze frequencies as a function of sample length or crystal orientation, an error analysis tool to assess fit quality, and formatting of the input and output files for batch fitting, e.g., as a function of temperature. This software was validated with published resonant ultrasound spectroscopy data for various materials, shapes, and symmetries with noted improvements in calculation time compared to finite element methods.

47 OTHER INSTRUMENTATION↗

XRIPL

XRIPL is a library of tools for processing x-ray radiographs and extracting contours of interest within the image using computer vision techniques. Features include spatial calibration, denoising, background and attenuation correction through pseudo-flatfielding, watershed segmentation, contour processing, and visualization. The details of the XRIPL analysis pipeline are published in the Proceedings of the 23rd Topical Conference on High-Temperature Plasma Diagnostics Proceedings (LA-UR-20-30133) [1]. [1] P. M. Kozlowski, Y. Kim, B. M. Haines, H. F. Robey, T. J. Murphy, H. M. Johns, and T. S. Perry. Use of Computer Vision for analysis of image data sets from high temperature plasma experiments. Review of Scientific Instruments 92, 033532 (2021) https://doi.org/10.1063/5.0040285

Kozlowski, Pawel↗

Performance analysis and data reduction for exascale scientific workflows

Chimbuko is the first in situ, scalable, workflow-level performance analysis tool for trace-level analysis and visualization of application performance. This tool was developed by the Co-design Center for Online Data Analysis and Reduction and funded by the U.S. Department of Energy’s Exascale Computing Project. We provide a detailed description of Chimbuko’s architecture and illustrate our online and offline visualization with multiple use cases. We also present results for the deployment and scalability of the tool as applied to a high-energy physics workflow running at large scale on the Frontier supercomputer.

97 MATHEMATICS AND COMPUTING↗

Selecting Essential Information for Biosurveillance—A Multi-Criteria Decision Analysis

The National Strategy for Biosurveillancedefines biosurveillance as ‘‘the process of gathering, integrating, interpreting, and communicating essential information related to all-hazards threats or disease activity affecting human, animal, or plant health to achieve early detection and warning, contribute to overall situational awareness of the health aspects of an incident, and to enable better decision-making at all levels.’’ However, the strategy does not specify how ‘‘essential information’’ is to be identified and integrated into the current biosurveillance enterprise, or what the metrics qualify information as being ‘‘essential’’. Thequestion of data stream identification and selection requires a structured methodology that can systematically evaluate the tradeoffs between the many criteria that need to be taken in account. Multi-Attribute Utility Theory, a type of multi-criteria decision analysis, can provide a well-defined, structured approach that can offer solutions to this problem. While the use of Multi-Attribute Utility Theoryas a practical method to apply formal scientific decision theoretical approaches to complex, multi-criteria problems has been demonstrated in a variety of fields, this method has never been applied to decision support in biosurveillance.We have developed a formalized decision support analytic framework that can facilitate identification of ‘‘essential information’’ for use in biosurveillance systems or processes and we offer this framework to the global BSV community as a tool for optimizing the BSV enterprise. To demonstrate utility, we applied the framework to the problem of evaluating data streams for use in an integrated global infectious disease surveillance system.

47 OTHER INSTRUMENTATION↗

Review of Quantitative Software Reliability Methods

The current U.S. Nuclear Regulatory Commission (NRC) licensing process for digital systems rests on deterministic engineering criteria. In its 1995 probabilistic risk assessment (PRA) policy statement, the Commission encouraged the use of PRA technology in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. Although many activities have been completed in the area of risk-informed regulation, the risk-informed analysis process for digital systems has not yet been satisfactorily developed. Since digital instrumentation and control (I&C) systems are expected to play an increasingly important role in nuclear power plant (NPP) safety, the NRC established a digital system research plan that defines a coherent set of research programs to support its regulatory needs. One of the research programs included in the NRC's digital system research plan addresses risk assessment methods and data for digital systems. Digital I&C systems have some unique characteristics, such as using software, and may have different failure causes and/or modes than analog I&C systems; hence, their incorporation into NPP PRAs entails special challenges. The objective of the NRC's digital system risk research is to identify and develop methods, analytical tools, and regulatory guidance for (1) including models of digital systems into NPP PRAs, and (2) using information on the risks of digital systems to support the NRC's risk-informed licensing and oversight activities. For several years, Brookhaven National Laboratory (BNL) has worked on NRC projects to investigate methods and tools for the probabilistic modeling of digital systems, as documented mainly in NUREG/CR-6962 and NUREG/CR-6997. However, the scope of this research principally focused on hardware failures, with limited reviews of software failure experience and software reliability methods. NRC also sponsored research at the Ohio State University investigating the modeling of digital systems using dynamic PRA methods. These efforts, documented in NUREG/CR-6901, NUREG/CR-6942, and NUREG/CR-6985, included a functional representation of the system's software but did not explicitly address failure modes caused by software defects or by inadequate design requirements. An important identified research need is to establish a commonly accepted basis for incorporating the behavior of software into digital I&C system reliability models for use in PRAs. To address this need, BNL is exploring the inclusion of software failures into the reliability models of digital I&C systems, such that their contribution to the risk of the associated NPP can be assessed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Summary Describing Integration of ERM Methodology into Supervisory Control Framework with Software Package Documentation; Advanced Reactor Technology Milestone: M4AT-16PN2301052

This project involved the development of enhanced risk monitors (ERMs) for active components in Advanced Reactor (AdvRx) designs by integrating real-time information about equipment condition with risk monitors. Health monitoring techniques in combination with predictive estimates of component failure based on condition and risk monitors can serve to indicate the risk posed by continued operation in the presence of detected degradation. This combination of predictive health monitoring based on equipment condition assessment and risk monitors can also enable optimization of maintenance scheduling with respect to the economics of plant operation. This report summarizes PNNL’s multi-year project on the development and evaluation of an ERM concept for active components while highlighting FY2016 accomplishments. Specifically, this report provides a status summary of the integration and demonstration of the prototypic ERM framework with the plant supervisory control algorithms being developed at Oak Ridge National Laboratory (ORNL), and describes additional case studies conducted to assess sensitivity of the technology to different quantities. Supporting documentation on the software package to be provided to ONRL is incorporated in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY17 ISCR Scholar End-of-Assignment Report - Robbie Sadre

Throughout this internship assignment, I did various tasks that contributed towards the starting of the SASEDS (Safe Active Scanning for Energy Delivery Systems) and CES-21 (California Energy Systems for the 21st Century) projects in the SKYFALL laboratory. The goal of the SKYFALL laboratory is to perform modeling and simulation verification of transmission power system devices, while integrating with high-performance computing. The first thing I needed to do was acquire official Online LabVIEW training from National Instruments. Through these online tutorial modules, I learned the basics of LabVIEW, gaining experience in connecting to NI devices through the DAQmx API as well as LabVIEW basic programming techniques (structures, loops, state machines, front panel GUI design etc).

24 POWER TRANSMISSION AND DISTRIBUTION↗