Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Integration of the Kromek D3S Detector and Spot Robot For Secondary Inspections

Inspecting vehicles and containers for the presence of nuclear material is a challenging task for border control and security. When performed manually by inspectors, this task also has an associated risk of exposing the inspectors to unknown radiation. With the advent of agile, easy-to-program, quadruped robots like the Boston Dynamics Spot, automation of secondary inspection can improve the efficiency of the inspection process and alleviates the radiation risks to inspectors. In this project, Brookhaven National Laboratory and the University of Massachussetts at Lowell explored how to automate a simple secondary inspection mission. The Spot robot comes with its own software development kit (SDK) that allows clients/users to write custom code in the Python programming language to control the robot. Spot also has a payload computer called Spot-CORE, which runs the Ubuntu Linux operating system and allows users to integrate external sensors, such as a radiation detector, with Spot. In this study, the Kromek D3S detector has been integrated with Spot via the Spot-CORE, allowing Spot to capture gamma spectra and neutron counts for a specified acquisition period. Two custom routines, search and confirmation, have been developed and executed in this specified order. The search routine directs Spot to go around the nearest obstacle, e.g., vehicle and container, in a preset distance and step to collect gamma and neutron gross counts with the D3S detector. The radiation data and the robot location corresponding to each step are stored and fed to the confirmation routine at the end of the search. The confirmation routine then navigates Spot to the locations of the highest gamma or neutron counts to perform a long, e.g., one minute, measurement, and gives the operators the signature gamma spectra and neutron counts at the hotspots. This paper presents a detailed description of this automated system along with results of the preliminary tests in identifying the location and signature of a 137Cs radiation source in a vehicle.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

HVAC control fine-grained occupancy pattern estimation

A thermal state of a plurality of zones of the building is updated according to a building thermal model and information received from temperature sensors of the building. Predicted occupant counts for an upcoming plurality of time slots for each of the plurality of zones are updated using actual occupancy counts for each of the plurality of zones. A misprediction type distribution for the upcoming plurality of time slots for each of the plurality of zones is updated, the misprediction type distribution indicating misprediction for true negatives, false positives, false negatives, and true positives. A total misprediction cost expectation is updated according to the predicted occupant counts and the misprediction type distribution. HVAC power for each of the plurality of zones is determined to optimize occupant thermal comfort weighted according to the predicted occupant counts while minimizing the total misprediction cost expectation. HVAC operation is controlled per the HVAC power.

Lin, Shan↗

Characteristic Performance Evaluation of a new SAGe Well Detector for Small and Large Sample Geometries

Environmental scientific research requires a detector that has sensitivity low enough to reveal the presence of any contaminant in the sample at a reasonable counting time. Canberra developed the germanium detector geometry called Small Anode Germanium (SAGe) Well detector, which is now available commercially. The SAGe Well detector is a new type of low capacitance germanium well detector manufactured using small anode technology capable of advancing many environmental scientific research applications. The performance of this detector has been evaluated for a range of sample sizes and geometries counted inside the well, and on the end cap of the detector. The detector has energy resolution performance similar to semi-planar detectors, and offers significant improvement over the existing coaxial and Well detectors. Energy resolution performance of 750 eV Full Width at Half Maximum (FWHM) at 122 keV γ-ray energy and resolution of 2.0 - 2.3 keV FWHM at 1332 keV γ-ray energy are guaranteed for detector volumes up to 425 cm{sup 3}. The SAGe Well detector offers an optional 28 mm well diameter with the same energy resolution as the standard 16 mm well. Such outstanding resolution performance will benefit environmental applications in revealing the detailed radionuclide content of samples, particularly at low energy, and will enhance the detection sensitivity resulting in reduced counting time. The detector is compatible with electric coolers without any sacrifice in performance and supports the Canberra Mathematical efficiency calibration method (In situ Object Calibration Software or ISOCS, and Laboratory Source-less Calibration Software or LABSOCS). In addition, the SAGe Well detector supports true coincidence summing available in the ISOCS/LABSOCS framework. The improved resolution performance greatly enhances detection sensitivity of this new detector for a range of sample sizes and geometries counted inside the well. This results in lower minimum detectable concentrations compared to Traditional Well detectors. The SAGe Well detectors are compatible with Marinelli beakers and compete very well with semi-planar and coaxial detectors for large samples in many applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the plutonium hold-up in glove box before dismantling - 15111

The French Bruyeres-Le-Chatel CEA (Commissariat a l'Energie Atomique et aux Energies Alternatives - French Alternatives Energies and Atomic Energy Commission) research center is going through a period of cleaning and dismantling of theses old treatment facilities on fissile materials and others associated nuclides. Some very large glove boxes contained some machines like melting furnace which can't be moved and are dismantled in situ. We need to evaluate the quantity of fissile materials to prevent criticality risk, to bring the evidence to the safety authority, to manage for the best the radioprotection of the workers and to manage waste production. A melting furnace in a glove box was dismantled. Measurements by gamma spectrometry with an HPGe detector (High Purity Germanium) and passive neutron counting (coincidence counting with shift register) are done in situ (furnace in the glove box). In order to refine the measurements, some data acquisitions by sector of glove box were carried out. In view of the geometries to characterize, some modelings have been created, in order to correct the different attenuations and to determine the plutonium masses content in the glove box, including the use of infinite energy technique. For the measurement by passive neutron counting (coincidence counting with shift register), we have used two slabs in high density polythene including nine He3 counters in each slab. This measurement technique is complementary to gamma spectrometry, and allows quantizing the fissile material which would be included in interstice of high Z material. The 100-L and 200-L drums produced during the dismantling were also measured. Based on simplified assumptions to analyze in situ measurements, plutonium weight could be evaluated. This approach of measurement in amount, during and after dismantling, has allowed to quantize the fissile material mass present in the glove box and didn't produce waste package which wouldn't respected the technical specifications of storage outlets. The results show good agreement between in situ and waste measurements. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Improvements to the operational efficiency of the Portsmouth 'Blue Box' Assay system - 15162

The 'Blue Box' in Building 326 at Portsmouth comprises a dual cargo container lined with high density polyethylene with 5% (elemental) boron that acts as a neutron shield. This construction provides a low environmental neutron background to support the capability to attain low values of minimal detectable activity (MDA). A Non-destructive Assay (NDA) measurement platform known as the Fluor B and W Portsmouth Slab Counter (FBPSC) is housed inside the Blue Box. This comprises four neutron slab detectors supported with an electronic system supplying power and associated signal processing. The system is operated by a laptop computer which has data acquisition and analysis capabilities. Each slab contains five {sup 3}He proportional counters embedded in polyethylene. The system is designed to measure the mass of U-235 in coolers from the Portsmouth site using passive neutron counting. The system was calibrated by taking measurements with {sup 252}Cf sources attached to various positions on the outside surfaces of a surrogate cooler. In addition, Monte-Carlo N-Particle (MCNP) simulations were performed to extend the baseline calibration for coolers of various sizes used in the gaseous-diffusion process. The basic principle of operation is to measure the total neutron emission from the item and determine the mass of {sup 235}U using the system efficiency (determined from MCNP calculations combined with the calibration measurements) combined with known isotopic information ({sup 235}U enrichment and U-235/U-234 ratio), assumed chemical composition, and gross cooler mass. The FBPSC analysis program calculates the mass of U-235 within the cooler being assayed, together with the associated Total Measurement Uncertainty (TMU). A background correction is performed that accounts for the measured environmental background with a cosmic-ray spallation correction (based on the cooler's gross weight). The software suite developed for the system also includes the capability to track and trend measurement control data in order to quickly identify conditions where the system has drifted outside of its quality control envelope. The MDA of the system has been determined to be less the 15 g of U-235 for count times that are typically less than 5 minutes (depending on the uranium isotopics). This is primarily the result of the low neutron background rate inside the Blue Box (approximately 3 times lower than at nearby locations outside the box). Additionally, various software features have been designed to yield optimum counting performance for the system including count time adjustment and interval filtering to reject statistical outliers that are usually associated with cosmic spallation events. The operation of the system has proven to be very efficient, with the short measurement time providing a high throughput rate of coolers through the Blue Box NDA system. Significant operational benefits and improved data traceability have been yielded compared to the previous measurement process, which involved operators taking measurement with counter/scalers and manually entering data into spreadsheets. As of August 2014, this system successfully measured all coolers required to support completion of a contractually-required Performance Milestone. There are approximately 1900 coolers available for measurement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Blending and In-Tank Pretreatment on Direct Feed Hanford High Level Waste Vitrification - 18434

A direct feed high level waste (DFHLW) option is under consideration for early operations of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). In this option, the Pretreatment Facility would be bypassed in order to support an earlier start-up of the HLW Vitrification Facility. For HLW, this would mean that ultrafiltration and caustic leaching that would otherwise have been performed either would not be performed or would be replaced by interim pretreatment functions such as in-tank washings. These changes could result in higher aluminum contents, higher chromium contents, higher fractions of supernate, and lower solids contents in the HLW feed. As a result, glass formulations and downstream vitrification operations will be impacted. In the present work, we investigate the effects of various waste blending and in-tank pretreatment scenarios on DFHLW glass waste loadings, canister counts, and processing rates. Eleven source tanks and five waste groups were selected for the studies of waste blending. In addition, the five waste groups selected were the subjects of an in-tank pretreatment study. Glass property-composition models and melter test data were used to calculate waste loadings, canister counts, processing rates, and treatment durations for a range of DFHLW scenarios. The processing scenarios were defined by the types of waste blending and in-tank pretreatment that were assumed. Blending cases were evaluated that ranged between the 'No Blend' and 'Total Blend' extremes and included pairwise blending (blending of two source tanks, either completely or in various proportions) and macro-batches formed from various combinations of the source tanks. Over 36,000 possible pairwise blending scenarios were evaluated and an optimal retrieval/blending sequence was identified. The waste loading of this optimal sequence is within 0.03 wt% of the 'Total Blend' case. Further, a total of 38 retrieval sequences were identified that have waste loadings within 0.1 wt% of the 'Total Blend' case. To evaluate the effects of in-tank pretreatment, an in-tank wash/settle/decant process was assumed and tank-specific wash factors were employed. Washing of the macro-batch blends gave a general increase in HLW loading, decrease in canister count, and decrease in glass yield. Glass yields are towards the low end of the values expected for the WTP, which could lead to lower than nominal glass production rates. The waste loading increases and canister count reductions with washing were small for two of the wastes indicating that direct treatment of the unwashed waste may be practical. For wastes that are relatively low in sulfate and halides, excessive washing is counterproductive. The results highlight the importance of maintaining high solids content in the HLW feed to maintain glass production rates. The results also illustrate that the optimum washing strategy will need to be evaluated on a tank-to-tank basis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Depleted Uranium Discrimination Using Spectral Ratios from Data-Starved Spectra - 18619

The Institute for Clean Energy Technology (ICET) has developed mobile surveying platforms for the retrieval of fired depleted uranium (DU) munitions. ICET surveying platforms are fitted with differential global positioning system (GPS), scintillation detectors, and central processing units (CPUs). The surveying technology has historically been used to assist facilities where DU contamination is a concern to locate, retrieve, and remediate DU-contaminated areas. Residence times over DU sources for mobile systems normally do not produce enough data to use gamma ray spectroscopy to verify the source type. Discussed is a potential method used to discriminate DU signatures in data-starved gamma ray spectral data collected during field surveys. Laboratory tests have shown that data-starved gamma ray spectra for zero-valence, oxide, and uranium ores can be distinguished from each other and from background by spectral ratioing. Zero-valence DU and DU oxide gamma ray signatures differ due to the attenuation of low-energy gammas emitted from U-238 daughters. DU signatures can be differentiated from naturally occurring uranium spectra due to the presence of daughters below U-234, primarily bismuth (Bi)-214, in the uranium decay series. Three primary regions of interest (ROI) within the analyzed test spectra are used to roughly characterize the shape of each test spectrum and compare them to background. The three ROIs are focused around the gamma-emitting daughters of U-238: thorium (Th)-234, protactinium (Pa)-234 metastable (m), and Bi-214. One of the three regions is considered the base region. This region is used to estimate what the counts in the other two regions should be by multiplying the counts in the ROIs by a ratio of background counts from an area previously found to be impacted. Using this spectral ratioing technique, a non-zero difference in spectral ratio values indicates a shift in the test spectra away from background. Calculating ratios between the base region and the other two regions allows for a graphical representation of the data in a two-dimensional spectral ratioing space, which is used to differentiate between the types of uranium sources previously mentioned. Surveying processes that are based on gross counts from scintillation counters can result in a large number of false positives as a result of shifting background signals or the presence of naturally occurring uranium. Application of the spectral ratioing technique can further assist in site characterization by analyzing all of the data-starved survey spectra to identify false positives or the need for additional data collection. Accurate surveys of DU testing and training ranges reduces the costs associated with range clean-up by discriminating clean areas from those requiring remediation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bayesian Framework for Bioburden Density Estimation in Planetary Protection

To comply with the international planetary protection policy set forth by the Committee on Space Research and NASA Agency level requirements, spacecraft destined to biologically sensitive planetary bodies have to minimize terrestrial biological contamination. Analysis, testing and inspection are the standard forward verification activities that are used to demonstrate compliance with the biological contamination requirements. For testing of spacecraft surface areas, a swab or wipe sample is collected from surfaces prior to last access and subsequently processed in the lab using NASA Approved Planetary Protection Methods for Culture Based Assays. Raw data resulting from this assay is then statistically treated employing a mathematical paradigm stemming from the 1970’s Viking Lander Project to generate the bioburden density and total microbial bioburden present. This standard approach arbitrarily accounts for error and provides an upper conservative bound as it reports the maximum number of spores estimated to be present on flight hardware surfaces. A bioburden density estimate factors in the following variables: the observed bioburden count, representative volume processed, sampling efficiencies. Notably, to account for error in the approach, a 0 observed count is arbitrarily changed to a count of 1 for each hardware grouping. The data generated by spacecraft bioburden verification campaigns in the past have resulted in <80% of wipes and <90% of swabs containing a bioburden count of 0. As such, having a robust and well documented statistical approach for dealing with the probability of low incident rates is necessary to be able to estimate spacecraft bioburden. Being able to statistically describe the bioburden distribution and associated confidence level is a gamechanger for the development of bioburden allocations during mission design and will allow for tighter management of risk throughout spacecraft build. Thus, Empirical Bayes statistical approach was evaluated to estimate the microbial bioburden on spacecraft to mitigate the aforementioned mathematical concerns and provide a probabilistic bioburden distribution of the flight hardware surface. For application of this approach to performing bioburden calculations, a range of non-informative prior assumptions on hardware surfaces are explored for Bayesian analyses while informative priors using posterior distributions from prior assays are utilized for Empirical Bayes analyses. Several non-informative priors are currently under investigation to assess fitness including use of these priors to serve as a foundation to build off of NASA specification values or a basis of risk to account for unknowns during the integration and testing process. Informative priors under consideration are generated using sampled bioburden values from hardware originating within like processing environments (e.g. vendor cleaning process or similar assembly process), temporal spacecraft status events as a prediction for hardware cleanliness of future samples, and heritage system bioburden actuals to predict allocation for subsequent missions. Informative priors and probabilistic bioburden distributions are then validated using data sets from the Mars Exploration Rover, Mars Science Laboratory, and InSight missions. Using Empirical Bayes approach to generate a probabilistic bioburden distribution as demonstrated through mission use cases provides a valid approach for use in the end-to-end requirements verification process.

97 - MATHEMATICS AND COMPUTING↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A system for the measurement of delayed neutrons and gammas from special nuclear materials

The delayed neutron counting (DNC) system at the Royal Military College of Canada has been upgraded to accommodate concurrent delayed neutron and gamma measurements. This delayed neutron and gamma counting (DNGC) system uses a SLOWPOKE-2 reactor to irradiate fissile materials before their transfer to a counting arrangement consisting of six ³He and one HPGe detector. The application of this system is demonstrated in an example where delayed neutron and gamma emissions are used in complement to examine ²³³U content and determine fissile mass with an average relative error and accuracy of -2.2 and 1.5 %, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Cryptographic robustness of a quantum cryptography system using phase-time coding

A cryptographic analysis is presented of a new quantum key distribution protocol using phase-time coding. An upper bound is obtained for the error rate that guarantees secure key distribution. It is shown that the maximum tolerable error rate for this protocol depends on the counting rate in the control time slot. When no counts are detected in the control time slot, the protocol guarantees secure key distribution if the bit error rate in the sifted key does not exceed 50%. This protocol partially discriminates between errors due to system defects (e.g., imbalance of a fiber-optic interferometer) and eavesdropping. In the absence of eavesdropping, the counts detected in the control time slot are not caused by interferometer imbalance, which reduces the requirements for interferometer stability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using [{sup 18}F]Fluorothymidine Imaged With Positron Emission Tomography to Quantify and Reduce Hematologic Toxicity Due to Chemoradiation Therapy for Pelvic Cancer Patients

Purpose: The purpose of the present prospective clinical trial was to determine the efficacy of [{sup 18}F]fluorothymidine (FLT)-identified active bone marrow sparing for pelvic cancer patients by correlating the FLT uptake change during and after chemoradiation therapy with hematologic toxicity. Methods and Materials: Simulation FLT positron emission tomography (PET) images were used to spare pelvic bone marrow using intensity modulated radiation therapy (IMRT BMS) for 32 patients with pelvic cancer. FLT PET scans taken during chemoradiation therapy after 1 and 2 weeks and 30 days and 1 year after completion of chemoradiation therapy were used to evaluate the acute and chronic dose response of pelvic bone marrow. Complete blood counts were recorded at each imaging point to correlate the FLT uptake change with systemic hematologic toxicity. Results: IMRT BMS plans significantly reduced the dose to the pelvic regions identified with FLT uptake compared with control IMRT plans (P<.001, paired t test). Radiation doses of 4 Gy caused an ∼50% decrease in FLT uptake in the pelvic bone marrow after either 1 or 2 weeks of chemoradiation therapy. Additionally, subjects with more FLT-identified bone marrow exposed to ≥4 Gy after 1 week developed grade 2 leukopenia sooner than subjects with less marrow exposed to ≥4 Gy (P<.05, Cox regression analysis). Apparent bone marrow recovery at 30 days after therapy was not maintained 1 year after chemotherapy. The FLT uptake in the pelvic bone marrow regions that received >35 Gy was 18.8% ± 1.8% greater at 30 days after therapy than at 1 year after therapy. The white blood cell, platelet, lymphocyte, and neutrophil counts at 1 year after therapy were all lower than the pretherapy levels (P<.05, paired t test). Conclusions: IMRT BMS plans reduced the dose to FLT-identified pelvic bone marrow for pelvic cancer patients. However, reducing hematologic toxicity is challenging owing to the acute radiation sensitivity (∼4 Gy) and chronic suppression of activity in bone marrow receiving radiation doses >35 Gy, as measured by the FLT uptake change correlated with the complete blood cell counts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

Evaluation of Am–Li neutron spectra data for active well type neutron multiplicity measurements of uranium

Safeguarding nuclear material is an important and challenging task for the international community. One particular safeguards technique commonly used for uranium assay is active neutron correlation counting. This technique involves irradiating unused uranium with ( α,n) neutrons from an Am-Li source and recording the resultant neutron pulse signal which includes induced fission neutrons. Although this non-destructive technique is widely employed in safeguards applications, the neutron energy spectra from an Am-Li sources is not well known. Several measurements over the past few decades have been made to characterize this spectrum; however, little work has been done comparing the measured spectra of various Am-Li sources to each other. This paper examines fourteen different Am-Li spectra, focusing on how these spectra affect simulated neutron multiplicity results using the code Monte Carlo N-Particle eXtended (MCNPX). Two measurement and simulation campaigns were completed using Active Well Coincidence Counter (AWCC) detectors and uranium standards of varying enrichment. The results of this work indicate that for standard AWCC measurements, the fourteen Am-Li spectra produce similar doubles and triples count rates. Finally, the singles count rates varied by as much as 20% between the different spectra, although they are usually not used in quantitative analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact multiwire proportional counters for the detection of fission fragments

Two large area multistep position sensitive (two dimensional) multiwire proportional counters have been developed for experiments involving study of fission dynamics using general purpose scattering chamber facility at IUAC. Both detectors have an active area of 20x10 cm{sup 2} and provide position signals in horizontal (X) and vertical (Y) planes, timing signal for time of flight measurements and energy signal giving the differential energy loss in the active volume. The design features are optimized for the detection of low energy heavy ions at very low gas pressures. Special care was taken in setting up the readout electronics, constant fraction discriminators for position signals in particular, to get optimum position and timing resolutions along with high count rate handling capability of low energy heavy ions. A custom made charge sensitive preamplifier, having lower gain and shorter decay time, has been developed for extracting the differential energy loss signal. The position and time resolutions of the detectors were determined to be 1.1 mm full width at half maximum (FWHM) and 1.7 ns FWHM, respectively. The detector could handle heavy ion count rates exceeding 20 kHz without any breakdown. Time of flight signal in combination with differential energy loss signal gives a clean separation of fission fragments from projectile and target like particles. The timing and position signals of the detectors are used for fission coincidence measurements and subsequent extraction of their mass, angular, and total kinetic energy distributions. This article describes systematic study of these fission counters in terms of efficiency, time resolution, count rate handling capability, position resolution, and the readout electronics. The detector has been operated with both five electrode geometry and four electrode geometry, and a comparison has been made in their performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-Ray Spectrometer Using 100-Pixel STJ Detectors for Synchrotron Radiation

Fluorescent X-ray absorption fine structure (XAFS) is an important tool for material analysis, especially for the measurement of chemical states or local structures of elements. Semiconductor detectors are usually used for separating the fluorescent of elements in question from background fluorescence. However, the semiconductor detectors cannot always discriminate K-lines of light elements and L-lines of various elements as different X-ray peaks at an energy range below about 3 keV. Superconducting tunnel junction (STJ) detectors are promising device for the soft X-ray at synchrotron radiation beam lines because of excellent energy resolution, high detection efficiency, and high counting rate. We are constructing a fluorescent X-ray spectrometer having 100-pixel array of STJs with 200 {mu}m square. The array detector is mounted on a liquid cryogen-free {sup 3}He cryostat. The sensitive area is the largest among the superconducting X-ray spectrometers operating at synchrotron beam lines. Each pixel is connected to a room temperature readout circuit that consists of a charge sensitive amplifier and a pulse height analyzer. The spectrometer will achieve a total solid angle of {approx}0.01 sr and a maximum counting rate of more than 1 M count per second. The present status of developments of our fluorescent X-ray spectrometer was reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗