Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Searches for new physics in the top quark samples at the CDF experiment

Twelve years after the discovery of the top quark at Fermilab's Tevatron, they are now finally beginning to shed light on this peculiarily massive quark. With 1-1.7 fb{sup -1} of integrated luminosity collected by the CDF detector, they are able to probe the knowledge of the top quark physics, and to search for signals of physics beyond the Standard Model. In this paper, they present results of measurements of top quark properties, as well as tests for the production mechanism of the top quark. They also describe CDF latest searches for beyond Standard Model couplings of the top quark. Finally, they present the most recent searches for direct production of new particles in the collected data samples.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A simultaneous measurement of the $b$-tagging efficiency scale factor and the $t\bar{t}$ Production Cross Section at the Collider Detector at Fermilab

The ability to compare results between Monte Carlo and data is imperative in modern experimental high-energy physics analyses. The b-tagging efficiency Scale Factor (SF) allows for an accurate comparison of b quark identification in data samples and Monte Carlo. This thesis presents a simultaneous measurement of the SF for the SecVtx algorithm and the t{bar t} production cross section using 5.6 fb{sup -1} of p{bar p} collision data at {radical}s = 1.96 TeV collected by the Collider Detector at Fermilab (CDF) experiment. The t{bar t} cross section was measured to be 7.26 {+-} 0.47 pb, consistent with prior CDF analyses. The tight SF value was measured to be 0.925 {+-} 0.032 and the loose SF value was measured at 0.967 {+-} 0.033. These are the most precise SF SecVtx measurements to be performed at CDF to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CompF2: Theoretical Calculations and Simulation Topical Group Report

This report summarizes the work of the Computational Frontier topical group on theoretical calculations and simulation for Snowmass 2021. We discuss the challenges, potential solutions, and needs facing six diverse but related topical areas that span the subject of theoretical calculations and simulation in high energy physics (HEP): cosmic calculations, particle accelerator modeling, detector simulation, event generators, perturbative calculations, and lattice QCD (quantum chromodynamics). The challenges arise from the next generations of HEP experiments, which will include more complex instruments, provide larger data volumes, and perform more precise measurements. Calculations and simulations will need to keep up with these increased requirements. The other aspect of the challenge is the evolution of computing landscape away from general-purpose computing on CPUs and toward special-purpose accelerators and coprocessors such as GPUs and FPGAs. These newer devices can provide substantial improvements for certain categories of algorithms, at the expense of more specialized programming and memory and data access patterns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Material separation in x-ray CT with energy resolved photon-counting detectors

Purpose: The objective of the study was to demonstrate that, in x-ray computed tomography (CT), more than two types of materials can be effectively separated with the use of an energy resolved photon-counting detector and classification methodology. Specifically, this applies to the case when contrast agents that contain K-absorption edges in the energy range of interest are present in the object. This separation is enabled via the use of recently developed energy resolved photon-counting detectors with multiple thresholds, which allow simultaneous measurements of the x-ray attenuation at multiple energies. Methods: To demonstrate this capability, we performed simulations and physical experiments using a six-threshold energy resolved photon-counting detector. We imaged mouse-sized cylindrical phantoms filled with several soft-tissue-like and bone-like materials and with iodine-based and gadolinium-based contrast agents. The linear attenuation coefficients were reconstructed for each material in each energy window and were visualized as scatter plots between pairs of energy windows. For comparison, a dual-kVp CT was also simulated using the same phantom materials. In this case, the linear attenuation coefficients at the lower kVp were plotted against those at the higher kVp. Results: In both the simulations and the physical experiments, the contrast agents were easily separable from other soft-tissue-like and bone-like materials, thanks to the availability of the attenuation coefficient measurements at more than two energies provided by the energy resolved photon-counting detector. In the simulations, the amount of separation was observed to be proportional to the concentration of the contrast agents; however, this was not observed in the physical experiments due to limitations of the real detector system. We used the angle between pairs of attenuation coefficient vectors in either the 5-D space (for non-contrast-agent materials using energy resolved photon-counting acquisition) or a 2-D space (for contrast agents using energy resolved photon-counting acquisition and all materials using dual-kVp acquisition) as a measure of the degree of separation. Compared to dual-kVp techniques, an energy resolved detector provided a larger separation and the ability to separate different target materials using measurements acquired in different energy window pairs with a single x-ray exposure. Conclusions: We concluded that x-ray CT with an energy resolved photon-counting detector with more than two energy windows allows the separation of more than two types of materials, e.g., soft-tissue-like, bone-like, and one or more materials with K-edges in the energy range of interest. Separating material types using energy resolved photon-counting detectors has a number of advantages over dual-kVp CT in terms of the degree of separation and the number of materials that can be separated simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interplay of energy dependent astrophysical neutrino flavor ratios and new physics effects

We discuss the importance of flavor ratio measurements in neutrino telescopes, such as by measuring the ratio between muon tracks to cascades, for the purpose of extracting new physics signals encountered by astrophysical neutrinos during propagation from the source to the detector. The detected flavor ratios not only carry the energy information of specific new physics scenarios which alter the transition probabilities in distinctive ways, but also the energy dependent flavor composition at the source. In the present work, we discuss the interplay of these two energy dependent effects and identify which new physics scenarios can be distinguished from the detected flavor ratios as a function of astrophysical parameters. We use a recently developed self-consistent neutrino production model as our toy model to generate energy dependent source flavor ratios and discuss (invisible) neutrino decay and quantum decoherence as specific new physics examples. Furthermore, we identify potentially interesting classes of sources on the Hillas plot for the purpose of new physics searches. We find that sources with substantial magnetic fields 10{sup 3} Gauss∼<B∼<10{sup 6} Gauss, such as Active Galactic Nuclei (AGN) cores, white dwarfs, or maybe gamma-ray bursts, have, in principle, the best discrimination power for the considered new physics scenarios, whereas AGN jets, which typically perform as pion beam sources, can only discriminate few sub cases in the new physics effects. The optimal parameter region somewhat depends on the class of new physics effect considered.

79 ASTRONOMY AND ASTROPHYSICS↗

Studying Neutrino Oscillations and Searches for BSM Physics with Atmospheric Neutrinos in DUNE

The 40kt DUNE Far Detector, located at the Sanford Underground Research Facility, will of- fer unique capabilities to study atmospheric neutrinos. Due to the detector’s excellent energy resolutions, angular resolutions, and particle ID capabilities, atmospheric neutrino analyses in DUNE can provide valuable information about 3-flavor oscillations, despite the relatively modest statistics. These data provide a complementary analysis approach to beam neutrinos, and can help in resolving ambiguities in beam-only analyses. In this paper we show the prospects on the determination of the mass hierarchy, octant of θ 23 , and measurement of δ CP using atmospheric neutrinos in DUNE. Atmospheric neutrinos can also lead to a variety of beyond the standard model scenarios for neutrino transitions, propagation, and interactions. Examples that have been previously studied include CPT violation, Lorentz invariance violation, non-standard interactions, mass varying neutrinos and sterile neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CLAS12 superconducting magnets

As part of the Jefferson Lab 12 GeV upgrade, the Hall B CLAS12 system requires two superconducting iron-free magnets — a torus and a solenoid. The physics requirements to maximize space for the detectors guided engineers toward particular coil designs for each of the magnets which, in turn, led to the choice of using conduction cooling. The torus consists of 6 trapezoidal NbTi coils connected in series with an operating current of 3770 A. The solenoid is an actively shielded 5 T magnet consisting of 5 NbTi coils connected in series operating at 2416 A. Within the hall, the two magnets are located in close proximity to each other and are completely covered both inside and outside by particle detectors. Stringent size limitations were imposed for both magnets and introduced particular design and fabrication challenges. This paper describes the design, construction, installation, commissioning, and operation of the two magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Triple Differential Muon Antineutrino Charge Current Inclusive Cross Section Measurement in NOvA

NOvA is a long-baseline accelerator-based neutrino experiment based in the USA. For its physics goals, NOvA uses two functionally identical detectors. The Near Detector is situated at Fermilab, 1 km from the neutrino target, and the Far Detector is located at Ash River, MN, a distance of 810 km from the neutrino source. The ND sees the high intensity of the neutrino beam due to its close proximity to the neutrino target, giving us a unique opportunity to do high-precision neutrino cross-section measurements. In this talk, we present our latest results of the muon antineutrino charge current inclusive cross-section measurement in the NOvA ND. The new measurement is a triple differential cross section in antimuon kinematic phase-space and in the total energy of all observable final state hadrons. We also compare our data results to various neutrino generator predictions, for example, comparisons to GENIE, NuWro, GiBUU, and NEUT neutrino generators are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Measurement of a Low-Noise 64-Channels Front-End Readout ASIC for CdZnTe Detectors

Cadmium zinc telluride (CdZnTe) detectors, as one of the principal detectors for the next-generation X-ray and γ-ray imagers, have high energy resolution and supporting electrode patterning in the radiation environment at room-temperature. In the present, a number of internationally renowned research institutions and universities are actively using these detector systems to carry out researches of energy spectrum analysis, medical imaging, materials characterization, high-energy physics, nuclear plant monitoring, and astrophysics. As the most important part of the readout system for the CdZnTe detector, the front-end readout application specific integrated circuit (ASIC) would have an important impact on the performances of the whole detector system. In order to ensure the small signal to noise ratio (SNR) and sufficient range of the output signal, it is necessary to design a front-end readout ASIC with very low noise and very high dynamic range. In addition, radiation hardness should be considered when the detectors are utilized in the space applications and high energy physics experiments. In this paper, we present measurements and performances of a novel multi-channel radiation-hardness low-noise front-end readout ASIC for CdZnTe detectors. The readout circuits in each channel consist of charge sensitive amplifier, leakage current compensation circuit (LCC), CR-RC shaper, S-K filter, inverse proportional amplifier, peak detect and hold circuit (PDH), discriminator and trigger logic, time sequence control circuit and driving buffer. All of 64 readout channels' outputs enter corresponding inputs of a 64 channel multiplexer. The output of the mux goes directly out of the chip via the output buffer. The 64-channel readout ASIC is implemented using the TSMC 0.35 μm mixed-signal CMOS technology. The die size of the prototype chip is 2.7 mm x 8 mm. At room temperature, the equivalent noise level of a typical channel reaches 66 e{sup -} (rms) at zero farad for a power consumption of 8 mW per channel. The linearity error is lower than 1% and the overall gain of the readout channel is 165 V/pC. The crosstalk between the channels is less than 3%. By connecting the readout ASIC to a CdZnTe detector, we obtained a γ-ray spectrum, the energy resolution is 5.1% at the 59.5-keV line of {sup 241}Am source. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of Selenium Addition to CdZnTe Matrix for Room-Temperature Radiation Detector Applications

Because of its ideal band gap, high density and high electron mobility-lifetime product, cadmium zinc telluride (CdZnTe or CZT) is currently the best room-temperature compound-semiconductor X- and gamma-ray detector material. However, because of its innate poor thermo-physical properties and above unity segregation coefficient for Zn, the wide spread deployment of this material in large-volume CZT detectors is still limited by the high production cost. The underlying reason for the low yield of high-quality material is that CZT suffers from three major detrimental defects: compositional inhomogeneity, high concentrations of dislocation walls/sub-grain boundary networks and high concentrations of Te inclusions/precipitates. To mitigate all these disadvantages, we report for the first time the effects of the addition of selenium to the CZT matrix. The addition of Se was found to be very effective in arresting the formation of sub-grain boundaries and its networks, significantly reducing Zn segregation, improving compositional homogeneity and resulting in much lower concentrations of Te inclusions/precipitates. Growth of the new quaternary crystal Cd 1-x Zn x Te 1-y Se y (CZTS) by the Traveling Heater Method (THM) is reported in this paper. We have demonstrated the production of much higher yield according to its compositional homogeneity, with substantially lower sub-grain boundaries and their network, and a lower concentration of Te inclusions/precipitates.

36 MATERIALS SCIENCE↗

Toward SBND's First Cross Section Measurements

The Short-Baseline Near Detector (SBND) is one of the Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors positioned along the axis of the Booster Neutrino Beam (BNB) at Fermilab, and is the near detector in the Short-Baseline Neutrino (SBN) Program. The detector completed commissioning and began taking neutrino data in the summer of 2024. SBND is characterized by superb imaging capabilities and recorded over two million neutrino interactions during its first physics run, which concluded in July 2025. Thanks to its unique combination of measurement resolution and statistics, SBND is carrying out a rich program of neutrino interaction measurements and novel searches for physics beyond the Standard Model (BSM). As the near detector, it will enable the full potential of the SBN sterile neutrino program by performing a precise characterization of the unoscillated event rate and constraining BNB flux and neutrino-argon cross-section systematic uncertainties. In addition, SBND will provide valuable model constraints for DUNE by leveraging the significant overlap in phase space between neutrino interactions in the two experiments. In this talk, I will present the current efforts within the SBND cross section program, discuss their status, and outline the plans for the first physics publications.

Oh, Sungbin [Fermilab]↗

Large size GEM for Super Bigbite Spectrometer (SBS) polarimeter for Hall A 12GeV program at JLab

We report on the R&D effort in the design and construction of a large size GEM chamber for the Proton Polarimeter of the Super Bigbite Spectrometer (SBS) in Hall A at Thomas Jefferson National Laboratory (JLab). The SBS Polarimeter trackers consist of two sets of four large chambers of size 200 cm x 60 cm 2 . Each chamber is a vertical stack of four GEM modules with an active area of 60 cm x 50 cm. We have built and tested several GEM modules and we describe in this paper the design and construction of the final GEM as well as the preliminary results on performances from tests carried out in our detector lab and with test beams at (Fermilab).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photometric calibrations for 21st century science

The answers to fundamental science questions in astrophysics, ranging from the history of the expansion of the universe to the sizes of nearby stars, hinge on our ability to make precise measurements of diverse astronomical objects. As our knowledge of the underlying physics of objects improves along with advances in detectors and instrumentation, the limits on our capability to extract science from measurements is set, not by our lack of understanding of the nature of these objects, but rather by the most mundane of all issues: the precision with which we can calibrate observations in physical units. In principle, photometric calibration is a solved problem - laboratory reference standards such as blackbody furnaces achieve precisions well in excess of those needed for astrophysics. In practice, however, transferring the calibration from these laboratory standards to astronomical objects of interest is far from trivial - the transfer must reach outside the atmosphere, extend over 4{pi} steradians of sky, cover a wide range of wavelengths, and span an enormous dynamic range in intensity. Virtually all spectrophotometric observations today are calibrated against one or more stellar reference sources, such as Vega, which are themselves tied back to laboratory standards in a variety of ways. This system's accuracy is not uniform. Selected regions of the electromagnetic spectrum are calibrated extremely well, but discontinuities of a few percent still exist, e.g., between the optical and infrared. Independently, model stellar atmospheres are used to calibrate the spectra of selected white dwarf stars, e.g. the HST system, but the ultimate accuracy of this system should be verified against laboratory sources. Our traditional standard star systems, while sufficient until now, need to be improved and extended in order to serve future astrophysics experiments. This white paper calls for a program to improve upon and expand the current networks of spectrophotometrically calibrated stars to provide precise calibration with an accuracy of equal to and better than 1% in the ultraviolet, visible and near-infrared portions of the spectrum, with excellent sky coverage and large dynamic range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics at the MeV-Scale in Liquid Argon Time Projection Chambers

The liquid argon time projection chamber (LArTPC) is the detection technology chosen for several Fermilab-based neutrino experiments. This technology will be used in studies of neutrino cross-sections and oscillations, neutrinos from supernovae as well as a variety of studies of beyond the Standard Model physics. This thesis explores the use of these detectors to study MeV-scale activity. MeV-scale electrons arising from Compton scatters of deexcitation photons and photons from inelastic neutron scattering in neutrino-nucleus interactions are reconstructed using novel methods presented here. This work represents the first demonstration of MeV-scale physics capabilities in a LArTPC neutrino experiment as well as the first observation of neutrino-produced photons from nuclear de-excitation and inelastic neutron scattering. A search for millicharged particles, postulated by theories of beyond the standard model physics, is also performed using data from a LArTPC and the low-ener gy reconstruction techniques developed. The results set world-leading bounds on the parameter space of millicharged particles. The work in this thesis demonstrates that studies of MeV-scale activity and new physics are possible with LArTPC technology and provides the foundation for future LArTPC studies of low energy neutrinos and new physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vector Boson plus Jets background to the early MET plus jets search

Searches in the large missing transverse momentum (MET) plus jets final state topology have great potential for discovery of new physics involving dark matter candidates during early LHC running. Standard Model processes that produce the same observable signature constitute the background to such searches. One of the main backgrounds is expected to come from higher-order QCD radiation in single vector boson production, which is difficult to model with Monte Carlo simulations. A strategy to estimate this background using data driven methods with various control samples is presented for early searches with the CMS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of low mass optical readout for high data bandwidth systems.

At Argonne National Laboratory the High Energy Physics and Center for Nanoscale Materials Divisions are working on a project to develop a new generation of detector readout using high speed data transfer optical devices that can be implemented in particle physics or for long distances. Free-space communications devices offer the potential for reductions in mass, power, and cost of data paths for on-board trigger and readout of tracking detectors. The project involves three areas of study: light modulation, the design and construction of MEMS optical devices, and the control systems for maintaining precise laser light positioning. We demonstrate an optical link in air over one meter and with low error rate at 1 Gb/s. We demonstrate steering of an optical beam over a meter with a precision of 5 micrometers utilizing a MEMS mirror and reflected light in the feedback loop. For early testing, light modulation tests with a fiber link using Li-Niobate modulators and a data generation and error checking chip are done at 1 Gb/s. Many companies and universities are developing modulators which will be incorporated into CMOS chips. We are doing radiation hardness studies for one of the materials involved. Laser light will need to be steered on to and kept centered on the detector in the presence of thermal or mechanical motion, etc. This steering will be controlled by MEMS mirrors. Polycrystalline and crystalline silicon based mirror designs are being studied. We review the current status of the project and outline plans for the future development of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗