Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Gas-phase flowrate effect on disintegrating cryogenic liquid-jets

Two phase liquid and gaseous nitrogen flow in a pneumatic two fluid atomizer was investigated. Characteristic dropsize for cryogenic sprays were measured with a scattered light scanning instrument developed at NASA-Lewis. Tests were conducted primarily in the aerodynamic stripping regime of liquid jet atomization. At a sampling distance of bar-x =1.3 cm, the Sauter mean, D(sub 32), and volume median, D(sub v.5), drop diameters were measured and correlated with nitrogen gas flowrate, W(sub n), to give the following expressions: D sub 32 to the -1=210W(sub n) to the -1.33 and D(sub v.5) to the -1=150 W(sub n to the -1.33, where reciprocal diameters and gas flowrate are in cm (-1) and g/sec, respectively. The exponent 1.33 for nitrogen gas flowrate, W(sub n), is the same as that predicted by atomization theory for liquid-jet breakup in high velocity gasflow. When the spray was sampled at axial distances of bar-x=2.5 and 4.5 cm downstream of the atomizer, the exponent decreased to 1.2 and 0.9, respectively. This was attributed to the loss of small droplets due to their rapid vaporization.

Ingebo, Robert D.↗

Heat transfer in a compact tubular heat exchanger with helium gas at 3.5 MPa

A compact heat exchanger was constructed consisting of circular tubes in parallel brazed to a grooved base plate. This tube specimen heat exchanger was tested in an apparatus which radiatively heated the specimen on one side at a heat flux of up to 54 W/sq cm, and cooled the specimen with helium gas at 3.5 MPa and Reynolds numbers of 3000 to 35,000. The measured friction factor of the tube specimen was lower than that of a circular tube with fully developed turbulent flow, although the uncertainty was high due to entrance and exit losses. The measured Nusselt number, when modified to account for differences in fluid properties between the wall and the cooling fluid, agreed with past correlations for fully developed turbulent flow in circular tubes.

Olson, Douglas A.↗

Heat transfer in a compact heat exchanger containing rectangular channels and using helium gas

Development of a National Aerospace Plane (NASP), which will fly at hypersonic speeds, require novel cooling techniques to manage the anticipated high heat fluxes on various components. A compact heat exchanger was constructed consisting of 12 parallel, rectangular channels in a flat piece of commercially pure nickel. The channel specimen was radiatively heated on the top side at heat fluxes of up to 77 W/sq cm, insulated on the back side, and cooled with helium gas flowing in the channels at 3.5 to 7.0 MPa and Reynolds numbers of 1400 to 28,000. The measured friction factor was lower than that of the accepted correlation for fully developed turbulent flow, although the uncertainty was high due to uncertainty in the channel height and a high ratio of dynamic pressure to pressure drop. The measured Nusselt number, when modified to account for differences in fluid properties between the wall and the cooling fluid, agreed with past correlations for fully developed turbulent flow in channels. Flow nonuniformity from channel-to-channel was as high as 12 pct above and 19 pct below the mean flow.

Olson, D. A.↗

Spacelab qualified infrared imager for microgravity science applications

The Lewis Research Center is developing, under contract, a Spacelab (manned module in the Space Shuttle payload bay) qualified infrared imager for noncontact surface temperature measurement in the Surface Tension Driven Convection Experiment, a microgravity fluid physics experiment. A versatile design philosophy was used in order to provide other experiments with essentially an off the shelf Shuttle qualified instrument, eliminating the duplication of the rigorous development and flight qualification processes. An Inframetrics Model 600 Scanning Infrared Radiometer is being modified to satisfy both experimental and flight requirements, while maintaining the basic performance parameters of the commercial instrument. The modifications include an efficient, low power closed cycle cryogenic cooler to cool the detector, a ruggedized scanner mechanism, 8 bit A/D conversion, Mil-STD components (where possible), size and weight optimization, and the addition of a microprocessor to perform automatic gain control. Features such as detector spectral response, the addition of spectral filters, and target temperature ranges could easily be changed to make this instrument useful as both a qualitative and quantitative diagnostic tool for Spacelab microgravity experiments, in combustion and fluid physics.

Pline, Alexander D.↗

Transport phenomena during vapor growth of optoelectronic material - A mercurous chloride system

Crystal growth velocity was measured in a mercurous chloride system in a two-zone transparent furnace as a function of the Rayleigh number by varying a/L, where a is the radius of the growth tube and L is the transport length. Growth velocity data showed different trends at low and high aspect ratio, a result that does not support the velocity-aspect ratio trend predicted by theories. The system cannot be scaled on the basis of measurements done at a low aspect ratio. Some change in fluid flow behavior occurs in the growth tube as the aspect ratio increases.

Singh, N. B.↗

Neural networks for calibration tomography

Artificial neural networks are suitable for performing pattern-to-pattern calibrations. These calibrations are potentially useful for facilities operations in aeronautics, the control of optical alignment, and the like. Computed tomography is compared with neural net calibration tomography for estimating density from its x-ray transform. X-ray transforms are measured, for example, in diffuse-illumination, holographic interferometry of fluids. Computed tomography and neural net calibration tomography are shown to have comparable performance for a 10 degree viewing cone and 29 interferograms within that cone. The system of tomography discussed is proposed as a relevant test of neural networks and other parallel processors intended for using flow visualization data.

Decker, Arthur↗

Flow and Drag Formulas for Simple Quadrics

This report gives the pressure distribution and resistance found by theory and experiment for simple quadrics fixed in an infinite uniform stream of practically incompressible fluid. The experimental values pertain to air and some liquids, especially water; the theoretical refer sometimes to perfect, again to viscid fluids. For the cases treated the concordance of theory and measurement is so close as to make a resume of results desirable. Incidentally formulas for the velocity at all points of the flow field are given, some being new forms for ready use derived in a previous paper. (author)

Zahm, A F↗

Theoretical and experimental investigation of heat transfer by laminar natural convection between parallel plates

Results are presented of a theoretical and experimental investigation of heat transfer involving laminar natural convection of fluids enclosed between parallel walls oriented in the direction of the body force, where one wall is heated uniformly, and the other is cooled uniformly. For the experimental work, parallel walls were simulated by using an annulus with an inner-to-outer diameter ratio near 1. The results of the theoretical investigation are presented in the form of equations for the velocity and temperature profiles and the ratio of actual temperature drop across the fluid to the temperature drop for pure conduction. No experimental measurements were made of the velocity and temperature profiles, but the experimental results are compared with theory on the basis of the ratio of the actual temperature drop to the temperature drop for pure conduction. Good agreement was obtained between theory and experiment for axial temperature gradients of 10 degrees F. per foot or larger.

Lietzke, A F↗

Mixing characteristics of directly opposed rows of jets injected normal to a crossflow in a rectangular duct

An experimental investigation of the mixing of nonreacting opposed rows of inline jets injected perpendicular to a uniform crossflow has been conducted in a rectangular duct. Planar Mie-scattering was used to measure the time-average concentration distribution of the jet fluid in planes perpendicular to the duct axis. Orifice configurations with geometric blockages ranging from 0.59 to 0.89 had similar mixing performance when compared at one-half duct height downstream of injection. Blockage was varied by changing the orifice aspect ratio from 1-to-1 to 1-to-1.5 while maintaining orifice spacing-to-duct height (S/H) at 0.425, jet-to-mainstream mass flow ratio (MR) at 2.0, and jet-to-mainstream momentum-flux ratio (J) at 48. The result indicates that the design correlating expression (at MR = 2) for optimum in line mixing of 2.5 approximately equal to (S/H)(square root of J) is independent of the Webb between adjacent orifices and therefore independent of orifice width. Experimental and numerical results for an orifice aspect ratio 1-to-1 case were in good agreement. The results of a comparison of inline 45 degrees slanted slot and round orifice configuration indicate that in order to obtain equivalent mean concentration distributions at the same J it is necessary to use a smaller S/H for the round orifice configuration. Conclusions about the performance of various orifice shapes can only be obtained from comparison of optimized configurations. Inline jets with different momentum-flux ratios on opposite sides were compared at a constant mass flow ratio. The orifice spacing chosen was previously found to be an optimum configuration when opposing values of J were equal and also an optimum for single side injection. Experimental and empirical results were in good agreement.

Liscinsky, D. S.↗

Storage and recycling of water and carbon dioxide in the earth

The stabilities and properties of water- and carbon-bearing phases in the earth have been determined from phase equilibrium measurements, combined with new data on the equations of state of water, carbon dioxide, carbonates and hydrates. The data have then been used to predict the fate of calcite and hydrous phases in subducting oceanic lithosphere. From the compositions of MORB's one can estimate concentrations of water and carbon of around 200 ppm and 80 ppm respectively in the upper mantle. Lower mantle estimates are very uncertain, but 1900 ppm water and 2000 ppm C are plausible concentrations. Measurements of the density of supercritical water to 3 GPa demonstrate that this phase is less compressible than anticipated from the equations of state of Haar et al. or Saul and Wagner and is closer to predictions based on molecular dynamics simulations. Conversely, fugacity measurements on carbon dioxide to 7 GPa show that this fluid is more compressible than predicted from the MRK equation of state. The results imply that hydrates are relatively more stable and carbonates less stable at pressures greater than 5 GPa than would be predicted from simple extrapolation of the low pressure data. Nevertheless, carbonates remain extremely refractory phases within both the upper and lower mantle.

Wood, Bernard J.↗

Coexistence Curve of Perfluoromethylcyclohexane-Isopropyl Alcohol

The coexistence curve of the binary fluid mixture perfluoromethylcyclohexane-isopropyl alcohol was determined by precisely measuring the refractive index both above and below its upper critical consolute point. Sixty-seven two-phase data points were obtained over a wide range of reduced temperatures, 10(exp -5) less than t less than 2.5 x 10(exp -1), to determine the location of the critical point: critical temperature=89.901 C, and critical composition = 62.2% by volume perfluoromethylcyclohexane. These data were analyzed to determine the critical exponent 8 close to the critical point, the amplitude B, and the anomaly in the diameter. The volume-fraction coexistence curve is found to be as symmetric as any composition like variable. Correction to scaling is investigated as well as the need for a crossover theory. A model is proposed that describes the asymptotic approach to zero of the effective exponent Beta, which allows an estimation of the temperature regime free of crossover effects.

Jacobs, D. T.↗

Near-Simultaneous POLAR and DMSP Measurements of Topside Ionospheric Up and Down Flows at High Latitudes

We will present what we believe to be the first reported observations of up- and downflows of topside ionospheric thermal plasmas from multiple near-simultaneous tracks through the high-latitude topside ionosphere. From several Southern polar passes, it has been possible to construct plots of field-aligned flows of 0+ observed by the Thermal Ion Dynamics Experiment(TIDE) on the POLAR spacecraft near 5000 km altitude together with vertical ion flow observations from one or more DMSP spacecraft near 800 km altitude. These observations provide a glimpse of the wide-spread upward and downward ionospheric ion flows over the broad polar region along multiple distinct satellite tracks. For the instances where DMSP and POLAR cross nearly the same field lines at the 800 and 5000 kin altitudes, we will show ion parameter measurements at these to altitudes in comparison to Dynamic Fluid-Kinetic(DyFK) transport simulations of anticipated altitude profiles of these parameters.

Zeng, W.↗

NASA SMART Probe: Breast Cancer Application

There is evidence in breast cancer and other malignancies that the physiologic environment within a tumor correlates with clinical outcome. We are developing a unique percutaneous Smart Probe to be used at the time of needle biopsy of the breast. The Smart Probe will simultaneously measure multiple physiologic parameters within a breast tumor. Direct and indirect measurements of tissue oxygen levels, blood flow, pH, and tissue fluid pressure will be analyzed in real-time. These parameters will be interpreted individually and collectively by innovative neural network techniques using advanced intelligent software. The goals are 1) develop a pecutaneous Smart Probe with multiple sensor modalities and applying advanced Information Technologies to provide real time diagnostic information of the tissue at tip of the probe, 2) test the percutaneous Smart Probe in women with benign and malignant breast masses who will be undergoing surgical biopsy, 3) correlate probe sensor data with benign and malignant status of breast masses, 4) determine whether the probe can detect physiologic differences within a breast tumor, and its margins, and in adjacent normal breast tissue, 5) correlate probe sensor data with known prognostic factors for breast caner, including tumor size, tumor grade, axillary lymph node metastases, estrogen receptor and progesterone receptor status.

Mah, Robert W.↗

Enhanced Mixing in a Rectangular Duct

An experimental investigation of the mixing of non-reacting opposed rows of jets injected normal to a confined rectangular crossflow has been conducted. Planar Mie-scattering was used to measure the time-average concentration distribution of the jet fluid in planes perpendicular to the duct axis. Particular emphasis was placed on the study of closely spaced orifice configurations applicable to the mixing zone of an RQL combustor. Baseline studies were performed of mixing under "ideal" conditions, i.e., plenum fed jets injecting into a crossflow uniform in velocity and turbulence intensity. In addition, more practical ("non-ideal") issues encountered during hardware design were also studied. As in other studies, mixing effectiveness, determined using a spatial unmixedness parameter based on the variance of mean jet concentration distributions, was found to be optimum when the spacing-to-duct-height ratio was inversely proportional to the square root of the jet-to-mainstream momentum-flux ratio. This relationship is suitable for design under ideal flow conditions. Inlet flow boundary conditions of the jet and approach flow (mainstream) were found to strongly influence mixing performance, but no attempt was made to determine optimum performance under non-ideal conditions. The tests performed do offer some guidance as to expected mixing behavior for several common variables likely to be imposed by hardware constraints. Additionally, in this study it was found that for rows of orifices with opposite centerlines inline, mixing was similar for blockages up to 89 percent (previous crossflow mixing studies concerned with dilution zone configurations, blockages were typically less than 50 percent). Lower levels of unmixedness were obtained as a function of downstream location when axial injection length was minimized. Mixing may be enhanced if orifice centerlines of opposed rows are staggered, but blockage must be =50 percent in this configuration. Round hole and "square" orifice shapes had similar performance. Other variations in orifice shape did not substantially augment overall mixing performance. Furthermore an isothermal mixing data set was generated and used by CFDRC as input to a NO(x) inference code.

Liscinsky, D. S.↗

Cardiovascular effects of a fractional -Gz force during a relatively prolonged exposure

Artificial hypogravity was created by having subjects remain in a supine position while undergoing rotation in an artificial gravity simulator. Various cardiovascular variables, such as heart rate, cardiac output, thoracic electric impedance, and blood pressure were measured. Results indicated that the hypogravity force produced a headward fluid shift, as seen by a decrease in thoracic impedance, which triggers regulatory neuroendocrine mechanisms. These findings are presented and discussed.

Non-NASA Center↗

Comparison of cardiovascular function during the early hours of bed rest and space flight

This paper reviews the cardiovascular responses of six healthy male subjects to 6 hours in a 5 degrees head-down bed rest model of weightlessness, and compares these responses to those obtained when subjects were positioned in head-up tilts of 10 degrees, 20 degrees, and 42 degrees, simulating 1/6, 1/3, and 2/3 G, respectively. Thoracic fluid index, cardiac output, stroke volume, and peak flow were measured using impedance cardiography. Cardiac dimensions and volumes were determined from two-dimensional guided M-mode echocardiograms in the left lateral decubitus position at 0, 2, 4, and 6 hours. Cardiovascular response to a stand test were compared before and after bed rest. The impedance values were related to tilt angle for the first 2 hours of tilt; however, after 3 hours, at all four angles, values began to converge, indicating that cardiovascular homeostatic mechanisms seek a common adapted state, regardless of effective gravity level (tilt angle) up to 2/3 G. Echocardiography revealed that left ventricular end-diastolic and end-systolic volume, stroke volume, ejection fraction, heart rate, and cardiac output had returned to control values by hour 6 for all tilt angles. The lack of a significant immediate change in left ventricular end-diastolic volume, despite decrements in stroke volume (P < .05) and heart rate (not significant), indicates that multiple factors may play a role in the adaptation to simulated hypogravity. The echocardiography data indicated that no angle of tilt, whether head-down or head-up for 4 to 6 hours, mimicked exactly the changes in cardiovascular function recorded after 4 to 6 hours of space flight. Changes in left ventricular end-diastolic volume during space flight and tilt may be similar, but follow a different time course. Nevertheless, head-down tilt at 5 degrees for 6 hours mimics some (stroke volume, systolic and diastolic blood pressure, mean arterial blood pressure, and total resistance), but not all, of the changes occurring in an equivalent time of space flight. The magnitude of the change in the mean heart rate response to standing was greater after six hours of tilt at -5 degrees or 10 degrees. Thus, results from the stand test after 6 hours of bed rest at -5 degrees and 10 degrees, but not at 20 degrees or 42 degrees, are similar to those obtained after space flight.

Space Flight↗

CARS Temperature and Species Measurements For Air Vehicle Propulsion Systems

The coherent anti-Stokes Raman spectroscopy (CARS) method has recently been used in the United States and Europe to probe several different types of propulsion systems for air vehicles. At NASA Langley Research Center in the United States, CARS has been used to simultaneously measure temperature and the mole fractions of N2, O2 and H2 in a supersonic combustor, representative of a scramjet engine. At Wright- Patterson Air Force Base in the United States, CARS has been used to simultaneously measure temperature and mole fractions of N2, O2 and CO2, in the exhaust stream of a liquid-fueled, gas-turbine combustor. At ONERA in France and the DLR in Germany researchers have used CARS to measure temperature and species concentrations in cryogenic LOX-H2 rocket combustion chambers. The primary aim of these measurements has been to provide detailed flowfield information for computational fluid dynamics (CFD) code validation.

Danehy, Paul M.↗

Integrating CFD, CAA, and Experiments Towards Benchmark Datasets for Airframe Noise Problems

Airframe noise corresponds to the acoustic radiation due to turbulent flow in the vicinity of airframe components such as high-lift devices and landing gears. The combination of geometric complexity, high Reynolds number turbulence, multiple regions of separation, and a strong coupling with adjacent physical components makes the problem of airframe noise highly challenging. Since 2010, the American Institute of Aeronautics and Astronautics has organized an ongoing series of workshops devoted to Benchmark Problems for Airframe Noise Computations (BANC). The BANC workshops are aimed at enabling a systematic progress in the understanding and high-fidelity predictions of airframe noise via collaborative investigations that integrate state of the art computational fluid dynamics, computational aeroacoustics, and in depth, holistic, and multifacility measurements targeting a selected set of canonical yet realistic configurations. This paper provides a brief summary of the BANC effort, including its technical objectives, strategy, and selective outcomes thus far.

Choudhari, Meelan M.↗