Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Testing and Development of a Percussive Augmenter for Rotary Drills

Hammering drills are effective in fracturing the drilled medium while rotary drills remove cuttings. The combination provides a highly effective penetration mechanism. Piezoelectric actuators were integrated into an adapter to produce ultrasonic percussion; augmenting rotary drilling. The drill is capable of operating at low power, low applied force and, with proper tuning, low noise. These characteristics are of great interest for future NASA missions and the construction/remodeling industry. The developed augmenter connects a commercially available drill and bit and was tested to demonstrate its capability. Input power to the drill was read using a multimeter and the augmenter received a separate input voltage. The drive frequency of the piezoelectric actuator was controlled by a hill climb algorithm that optimizes and records average power usage to operate the drill at resonating frequency. Testing the rotary drill and augmenter across a range of combinations with total power constant at 160 Watts has shown results in concrete and limestone samples that are as good as or better than the commercial drill. The drill rate was increased 1.5 to over 10 times when compared to rotation alone.

rotary-hammering↗

The Effect of a Hall Thruster-Like Magnetic Field on Operation of a 25-A Class Hollow Cathode

The effect of applying a Hall thruster-like magnetic field to a 25-A class hollow cathode is experimentally characterized. A magnetic simulator that approximated the magnetic field of NASA's HERMeS Hall thruster was used to apply magnetic fields of strengths that varied from 0 to 1.25 of the nominal HERMeS value Bnom. Cathode operation was characterized by parameters such as the discharge voltage, voltage and current oscillation magnitudes, and ion energy spectra. It was found that the application of the magnetic field profoundly affected the operation of the cathode. For the nominal xenon flow rate of 14.7 sccm, when increasing the magnetic field from 0 Bnom to 1.25 Bnom, the discharge voltage increased from 20 V to 40 V and the cathode orifice plate temperature increased from 934 ºC to 987 ºC. Oscillations of the discharge voltage, discharge current, and keeper voltage all remained relatively quiescent. However, the ion energy spectra changed profoundly between conditions, with little ion population above 50 V at 0 Bnom, yet a high-energy ion tail extending above 150 V at the 1.25 Bnom case. These high-energy ions appeared without an increase in the oscillation levels, indicating that previous cathode mode definitions may not apply with the Hall thruster-like magnetic field. The implications of these results on existing cathode operational mode definitions, component-level cathode testing, and operation in a Hall thruster are discussed.

Hall, Scott J.↗

Digitally Controlled High Availability Power Supply

This paper reports the design and test results on novel topology, high-efficiency, and low operating temperature, 1,320-watt power modules for high availability power supplies. The modules permit parallel operation for N+1 redundancy with hot swap capability. An embedded DSP provides intelligent start-up and shutdown, output regulation, general control and fault detection. PWM modules in the DSP drive the FET switches at 20 to 100 kHz. The DSP also ensures current sharing between modules, synchronized switching, and soft start up for hot swapping. The module voltage and current have dedicated ADCs (>200 kS/sec) to provide pulse-by-pulse output control. A Dual CAN bus interface provides for low cost redundant control paths. Over-rated module components provide high reliability and high efficiency at full load. Low on-resistance FETs replace conventional diodes in the buck regulator. Saturable inductors limit the FET reverse diode current during switching. The modules operate in a two-quadrant mode, allowing bipolar output from complimentary module groups. Controllable, low resistance FETs at the input and output provide fault isolation and allow module hot swapping.

43 PARTICLE ACCELERATORS↗

Vehicle Technologies Program: Energy Storage R&D (2008 Annual Progress Report)

One of the primary objectives of the Energy Storage effort is the development of durable and affordable advanced batteries (and ultracapacitors) for use in a full range of vehicle applications, from start/stop to full-power HEVs, EVs, and PHEVs. The battery technology development activity spans three areas: system development of full battery systems; benchmark testing of emerging technologies in order to remain abreast of the latest industry developments; and Small Business Innovative Research (SBIR) to fund early-stage R&D for small businesses/entrepreneurs.

25 ENERGY STORAGE↗

Dual-Salt Electrolytes to Effectively Reduce Impedance Rise of High-Nickel Lithium-Ion Batteries

Simply mixing several lithium salts in one electrolyte to obtain blended salt electrolytes has been demonstrated as a promising strategy to formulate advanced electrolytes for lithium metal batteries (LMBs) and lithium-ion batteries (LIBs). In this study, we report the use of dual-salt electrolytes containing lithium hexafluorophosphate (LiPF6) and lithium difluorophosphate (LiDFP) in ethylene carbonate/ethyl methyl carbonate (EC/EMC) mixture and tested them in layered high-nickel LIB cells. LiNi 0.94 Co 0.06 O 2 was synthesized through a coprecipitation method and was used as a representative high-nickel cathode for the U.S. DOE realizing next-generation cathode (RNGC) deep dive program. The ionic conductivity of dual-salt electrolytes can be maintained by controlling the amount of LiDFP. Techniques including 1 H Nuclear Magnetic Resonance (NMR), X-ray photoelectron spectroscopy (XPS), inductively coupled plasma-mass spectrometry (ICP-MS), and differential voltage analysis (DVA) were used to understand the improved performance. Additionally, the multifaceted benefits of using the dual-salt electrolytes include (1) reduced transesterification, (2) formation of a stable cathode electrolyte interface, and (3) mitigation of cathode degradation at high voltages, especially stabilization of oxide particles during the H 2 <-> H 3 transformation.

25 ENERGY STORAGE↗

Understanding Recoverable vs Unrecoverable Voltage Losses and Long-Term Degradation Mechanisms in Anion Exchange Membrane Fuel Cells

Anion exchange membrane fuel cells (AEMFCs) have recently shown excellent progress in terms of their performance – e.g., achievable power and current density. However, very few AEMFCs have been demonstrated with the ability to operate for a long duration (>1000 h). In addition, it is unknown whether performance losses observed during operation are reversible, irreversible, or a combination of the two. In this study, a high-performance AEMFC operated continuously at 600 mA/cm 2 for 3600 h (150 days) at 80 °C with H 2 /O 2 reacting gases was demonstrated. Throughout testing, the electrochemical properties of the AEMFC were probed to provide information about performance degradation pathways and their degree of reversibility. It was found that a portion of the performance loss that occurs during AEMFC operation was due to suboptimal reaction conditions and can be recovered. At the end of the experiment, the cell was disassembled, and its structure and composition were evaluated at the nanoscale by aberration-corrected scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy. The structure and composition of the electrode were compared to cells at the beginning of their operational life. It was found that the primary mechanism for long-term AEMFC performance loss was catalyst agglomeration. During the operational time, there was no evidence of significant polymer degradation, likely due to the high hydration state of the cell. By documenting the long-term changes in high-performing AEMFCs, this work provides important information for the systematic design of cell components and demonstrates the importance of controlling cell operation, which can aid in the commercialization and widespread deployment of low-cost, long-life AEMFCs.

30 DIRECT ENERGY CONVERSION↗

Two-dimensional hybrid Monte Carlo–fluid modelling of dc glow discharges: Comparison with fluid models, reliability, and accuracy

Two-dimensional hybrid Monte Carlo–fluid numerical code is developed and applied to model the dc glow discharge. The model is based on the separation of electrons into two parts: the low energetic (slow) and high energetic (fast) electron groups. Ions and slow electrons are described within the fluid model using the drift-diffusion approximation for particle fluxes. Fast electrons, represented by suitable number of super particles emitted from the cathode, are responsible for ionization processes in the discharge volume, which are simulated by the Monte Carlo collision method. Electrostatic field is obtained from the solution of Poisson equation. The test calculations were carried out for an argon plasma. Main properties of the glow discharge are considered. Current-voltage curves, electric field reversal phenomenon, and the vortex current formation are developed and discussed. The results are compared to those obtained from the simple and extended fluid models. Contrary to reports in the literature, the analysis does not reveal significant advantages of existing hybrid methods over the extended fluid model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal Submodule Capacitor Sizing for Modular Multilevel Converters with Common Mode Voltage Injection and Circulating Current Control

Abstract - Modular multilevel converters (MMCs), with the filterless and transformer-less features, are considered as a promising topology for high-efficiency medium voltage (MV) high voltage (HV) drive systems. However, at low frequencies (< 30 Hz), a large current ripple flowing through the capacitors of each submodule will cause significant capacitor voltage fluctuation. This paper proposes an optimal submodule capacitor selection based on the common mode voltage injection. The proposed sizing model includes two functions: a) accurately estimating the capacitor voltage ripple based on the drive system parameters; and b) identifying the minimum capacitance of the submodule capacitors based on the allowed maximum capacitor voltage fluctuations. Simulation and hardware-in-the-loop (HIL) test results show that the error between the actual and estimated values of the voltage fluctuation is within 3% using the proposed model.

Capacitor Sizing↗

Performance Characteristics of Pixelated CZT Crystals used on the GammaTracker Project

GammaTracker is a handheld radioisotope identification device in development at Pacific Northwest National Laboratory that uses eighteen pixelated Cadmium-Zinc Telluride (CZT) crystals to provide energy resolution approaching that of high-purity germanium without the need for cryogenic cooling. Additionally, these crystals can be used to provide directional and imaging capabilities that cannot be found in other handheld detectors. A significant number of CZT crystals have been procured during the development of the GammaTracker system; the majority of these were procured with the same set of specifications. Each of these detectors has been characterized in terms of key parameters, including current-voltage response and pixel-by-pixel energy resolution. The results of this testing indicate that the overall quality of CZT crystals is improving over time.

Becker, Eric M.↗

Design considerations for silicon HLE solar cells

The high-low (H-L) junction in the emitter region that defines the high-low-junction emitter (HLE) solar cell suppresses the dark emitter recombination current J sub E so that the base recombination current dominates in determining the open-circuit voltage. For silicon cells this enables the achievement of considerably larger values of open-circuit voltage than those achievable in conventional structures. This paper describes experiments that demonstrate the achievement of J sub E suppression (to less than 5 x 10 to the -14th A/sq cm) and large open-circuit voltage (640 mV) in HLE test cells of two distinct types. In the first type (the diffused HLE structure) impurity diffusion forms the H-L junction in the emitter; in the second type (the oxide-charge-induced HLE structure) the H-L junction is formed in emitter material of relatively low doping concentration by an oxide-charge-induced electron accumulation layer.

Lindholm, F. A.↗

NASA Tech Briefs, March 2006

Topics covered include: Medical Signal-Conditioning and Data-Interface System; Instruments for Reading Direct-Marked Data-Matrix Symbols; Processing EOS MLS Level-2 Data; Ground Processing of Data From the Mars Exploration Rovers; Estimating Total Electron Content Using 1,000+ GPS Receivers; NASA Solar Array Demonstrates Commercial Potential; Improved Control of Charging Voltage for Li-Ion Battery; Programmable Pulse-Position-Modulation Encoder; Wavelength-Agile External-Cavity Diode Laser for DWDM; Pattern-Recognition Processor Using Holographic Photopolymer; Submicrosecond Power-Switching Test Circuit; Three-Function Logic Gate Controlled by Analog Voltage; Integrated System for Autonomous Science; Montage Version 3.0; Utilizing AI in Temporal, Spatial, and Resource Scheduling; Satellite Image Mosaic Engine; Architecture for Control of the K9 Rover; HFGMC Enhancement of MAC/GMC; Automated Activation and Deactivation of a System Under Test; Cleaning Carbon Nanotubes by Use of Mild Oxygen Plasmas; Generating Aromatics From CO2 on Mars or Natural Gas on Earth; Attaching Thermocouples by Peening or Crimping; Heat Treatment of Friction-Stir-Welded 7050 Aluminum Plates; Generating Breathable Air Through Dissociation of N2O; High-Performance Scanning Acousto-Ultrasonic System; Correction for Thermal EMFs in Thermocouple Feedthroughs; Using Quasiparticle Poisoning To Detect Photons; Estimating Resolution Lengths of Hybrid Turbulence Models; Education and Training Module in Alertness Management; Cargo-Positioning System for Next-Generation Spacecraft; Micro-Imagers for Spaceborne Cell-Growth Experiments; Holographic Solar Photon Thrusters; Plasma-Based Detector of Outer-Space Dust Particles; and Generation of Data-Rate Profiles of Ka-Band Deep-Space Links.

Source record↗

Radiation-Hard SpaceWire/Gigabit Ethernet-Compatible Transponder

A radiation-hard transponder was developed utilizing submicron/nanotechnology from IBM. The device consumes low power and has a low fabrication cost. This device utilizes a Plug-and-Play concept, and can be integrated into intra-satellite networks, supporting SpaceWire and Gigabit Ethernet I/O. A space-qualified, 100-pin package also was developed, allowing space-qualified (class K) transponders to be delivered within a six-month time frame. The novel, optical, radiation-tolerant transponder was implemented as a standalone board, containing the transponder ASIC (application specific integrated circuit) and optical module, with an FPGA (field-programmable gate array) friendly parallel interface. It features improved radiation tolerance; high-data-rate, low-power consumption; and advanced functionality. The transponder utilizes a patented current mode logic library of radiation-hardened-by-architecture cells. The transponder was developed, fabricated, and radhard tested up to 1 MRad. It was fabricated using 90-nm CMOS (complementary metal oxide semiconductor) 9 SF process from IBM, and incorporates full BIT circuitry, allowing a loop back test. The low-speed parallel LVCMOS (lowvoltage complementary metal oxide semiconductor) bus is compatible with Actel FPGA. The output LVDS (low-voltage differential signaling) interface operates up to 1.5 Gb/s. Built-in CDR (clock-data recovery) circuitry provides robust synchronization and incorporates two alarm signals such as synch loss and signal loss. The ultra-linear peak detector scheme allows on-line control of the amplitude of the input signal. Power consumption is less than 300 mW. The developed transponder with a 1.25 Gb/s serial data rate incorporates a 10-to-1 serializer with an internal clock multiplication unit and a 10-1 deserializer with internal clock and data recovery block, which can operate with 8B10B encoded signals. Three loop-back test modes are provided to facilitate the built-in-test functionality. The design is based on a proprietary library of differential current switching logic cells implemented in the standard 90-nm CMOS 9SF technology from IBM. The proprietary low-power LVDS physical interface is fully compatible with the SpaceWire standard, and can be directly connected to the SFP MSA (small form factor pluggable Multiple Source Agreement) optical transponder. The low-speed parallel interfaces are fully compatible with the standard 1.8 V CMOS input/output devices. The utilized proprietary annular CMOS layout structures provide TID tolerance above 1.2 MRad. The complete chip consumes less than 150 mW of power from a single 1.8-V positive supply source.

Katzman, Vladimir↗

Radiation-Hard Parallel Readout Circuit for Low-Frequency Voltage Signal Measurements

NASA Goddard Space Flight Center (GSFC) has successfully developed and tested a custom-designed low-noise multi-channel digitizer (MCD) application specific integrated circuit (ASIC) for operation in harsh radiation environments. The MCD-ASIC is optimized for low-frequency and low-voltage signal measurements from sensors and transducers. It has 20 input channels where each channel is comprised of auto-zeroed chopper variable-gain amplifier, post amplifier, and a second order ∑∆ modulator. ∑∆ analog-to-digital converter (ADC) relies on oversampling and noise shaping to achieve high-resolution conversion. However, the MCD-ASIC requires digital filtering and decimation to convert the output single bit streams from the ADC to useful data words. A parallel digital platform such as a field-programmable-gate-array (FPGA) is highly suitable to fully leverage the capabilities of the MCD-ASIC. The FPGA controls the MCD-ASIC via serial peripheral interface (SPI) protocol and acquires data from it. A Python-script communicates with the FPGA board through a USB interface on a cross operating platform. Using this architecture, the system is capable of monitoring up to 20 voltage readout channels simultaneously in a real-time manner. Each channel’s parameters can be programmed independently allowing maximum user versatility. In this paper, we present analysis of the analog front-end, the implementation of the digital processing unit on the FPGA, and provide noise performance results from the MCD-ASIC readout.

ASIC↗

Development of a High Frequency Class-A Amplifier for High Temperature Wireless Microsystems based on a Silicon Carbide Static Induction Transistor

Next generation gas turbine engine health monitoring for high performance jet engine-powered aircraft will incorporate integrated microelectronic sensors specifically designed to enhance aircraft functionality, engine efficiency, and safety. Temperature, air flow and pressure associated with the gas path as well as emissions from the engine correlate to the state of the combustor and other engine health conditions. Monitoring these parameters accurately requires positioning electronic sensors in the hot zone of the gas turbine engine, which exposes them to temperatures in excess of 400ºC. At these temperatures, signal amplification is needed at the transducer level to distinguish the desired measured signal from the significant electronic noise generated by the harsh environment. In this presentation, we report on the simulation, development, fabrication, and testing on a high temperature Class-A amplifier which utilizes a 4H-SiC Static Induction Transistor (SIT) as the active device and input/output matching and DC bias networks comprised of thin-film spiral inductors, metal-insulator-metal capacitors, and thick film chip resistors. A small signal model that emulates the operation of the 4H-SiC SIT from 25 to 400ºC, with an emphasis on operation at 400οC, was utilized. Measurements were performed from 25 to 400ºC to generate current-voltage curves, capacitive transistor characteristics and high frequency scattering parameters (S-parameters). The measured data was used to extrapolate the transconductance, gm, as a function of temperature for model development. Circuit simulation tools were used to generate S-parameters, which were compared to the measured values. At 400οC, a maximum difference between measured and simulated S-parameters for frequencies from 20 to 100 MHz were 3.84%, 0.68%, 10.61%, and 3.26% for S21, S12, S11, and S22, respectively. The average transit frequency, ft, was calculated from measured values to be 197.8 MHz, while the simulated value from the model was found to be 200 MHz. The Amplifier’s S-parameters were recorded at 20-100 MHz over a temperature range of 25-400ºC and show a gain of approximately 15.8 and 5.80 dBm at 25 and 400ºC, respectively. The input and output reflection coefficients at 50 MHz and 400ºC were -18.5 and -15.2 dB, respectively. The noise figure and phase noise were measured over the temperature range of 25-400ºC and recorded. The noise figure increased 21% at 50 MHz over the temperature range, while the 1 kHz offset of the phase noise remained below -110 dB. The stability factor, K, calculated with measured and simulated data demonstrates unconditional stability over the frequency range at 400ºC. Lastly, the 1-dB compression point was measured at 50 MHz and 400ºC with an approximated output of 9.5 dBm.

SiC↗

New Test Rig to Measure Alternating Current Losses of Both Low and High Critical Temperature Superconductors

This paper presents the design, development, operation, and test capabilities of a proposed superconducting coil testbed to measure alternating current (AC) losses at the NASA Glenn Research Center. Superconducting AC losses are important in the design of electric stators and rotors, power transmission lines, transformers, fault current limiters, magnets, and superconducting energy storage (not batteries). The new liquid-hydrogen-based rig will allow superconducting testing across a wide range of test parameters, including injected current up to 400 A, frequency (0 to 400 Hz), magnetic field (0 to 0.6 T), phase angle between induced voltage and injected current (–180° to 180°), coil coolant temperature (18 to 28 K), and AC power loss (5 to 30 W). While the target application of interest is 20 K superconducting MgB2 (the only superconductor that can presently be made with low losses) stator coils for future electric machines, the rig can accommodate test articles (TAs) with straight wire, tape, cables, coils of any shape, any allowable combination of superconducting wire and fluid (e.g., yttrium barium copper oxide (YBCO) coils and liquid nitrogen), and AC or direct current (DC) testing. The new spin rig builds upon the existing Air Force spin rig through a more flexible mode of fluid control, a wider gap space (up to 10.2 cm) for TAs, and the ability to accommodate TAs over a wider range of operating temperatures (18 to 95 K) using liquid hydrogen, gaseous helium, or liquid nitrogen as the working fluid, thus supporting direct cooled machines below 77 K.

liquid hydrogen↗

Reliability Effects of Surge Current Testing of Solid Tantalum Capacitors

Solid tantalum capacitors are widely used in space applications to filter low-frequency ripple currents in power supply circuits and stabilize DC voltages in the system. Tantalum capacitors manufactured per military specifications (MIL-PRF-55365) are established reliability components and have less than 0.001% of failures per 1000 hours (the failure rate is less than 10 FIT) for grades D or S, thus positioning these parts among electronic components with the highest reliability characteristics. Still, failures of tantalum capacitors do happen and when it occurs it might have catastrophic consequences for the system. This is due to a short-circuit failure mode, which might be damaging to a power supply, and also to the capability of tantalum capacitors with manganese cathodes to self-ignite when a failure occurs in low-impedance applications. During such a failure, a substantial amount of energy is released by exothermic reaction of the tantalum pellet with oxygen generated by the overheated manganese oxide cathode, resulting not only in destruction of the part, but also in damage of the board and surrounding components. A specific feature of tantalum capacitors, compared to ceramic parts, is a relatively large value of capacitance, which in contemporary low-size chip capacitors reaches dozens and hundreds of microfarads. This might result in so-called surge current or turn-on failures in the parts when the board is first powered up. Such a failure, which is considered as the most prevalent type of failures in tantalum capacitors [I], is due to fast changes of the voltage in the circuit, dV/dt, producing high surge current spikes, I(sub sp) = Cx(dV/dt), when current in the circuit is unrestricted. These spikes can reach hundreds of amperes and cause catastrophic failures in the system. The mechanism of surge current failures has not been understood completely yet, and different hypotheses were discussed in relevant literature. These include a sustained scintillation breakdown model [1-3]; electrical oscillations in circuits with a relatively high inductance [4-6]; local overheating of the cathode [5,7, 8]; mechanical damage to tantalum pentoxide dielectric caused by the impact of MnO2 crystals [2,9, 10]; or stress-induced-generation of electron traps caused by electromagnetic forces developed during current spikes [11]. A commonly accepted explanation of the surge current failures is that at unlimited current supply during surge current conditions, the self-healing mechanism in tantalum capacitors does not work, and what would be a minor scintillation spike if the current were limited, becomes a catastrophic failure of the part [l, 12]. However, our data show that the scintillation breakdown voltages are significantly greater that the surge current breakdown voltages, so it is still not clear why the part, which has no scintillations, would fail at the same voltage during surge current testing (SCT).

Teverovsky, Alexander↗

Test of a 1.8 Tesla, 400 Hz Dipole for a Muon Synchrotron

A 1.8 T dipole magnet using thin grain oriented silicon steel laminations has been constructed as a prototype for a muon synchrotron ramping at 400 Hz. Following the practice in large 3 phase transformers and our own Opera-2d simulations, joints are mitred to take advantage of the magnetic properties of the steel which are much better in the direction in which the steel was rolled. Measurements with a Hysteresigraph 5500 and Epstein frame show a high magnetic permeability which minimizes stored energy in the yoke allowing the magnet to ramp quickly with modest voltage. Coercivity is low which minimizes hysteresis losses. A power supply with a fast Insulated Gate Bipolar Transistor (IGBT) switch and a capacitor was constructed. Coils are wound with 12 gauge copper wire. Thin wire and laminations minimize eddy current losses. The magnetic field was measured with a peak sensing Hall probe.

36 MATERIALS SCIENCE↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗