Search NASA⌕ Search

SEARCH · Search NASA

Results for “Implementation Plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Extreme Compression for Large Scale Data Store

For the last 5 years Accelogic pioneered and perfected a radically new theory of numerical computing codenamed “Compressive Computing”, which has an extremely profound impact on real-world computer science [1]. At the core of this new theory is the discovery of one of its fundamental theorems which states that, under very general conditions, the vast majority (typically between 70% and 80%) of the bits used in modern large-scale numerical computations are absolutely irrelevant for the accuracy of the end result. This theory of Compressive Computing provides mechanisms able to identify (with high intelligence and surgical accuracy) the number of bits (i.e., the precision) that can be used to represent numbers without affecting the substance of the end results, as they are computed and vary in real time. The bottom line outcome would be to provide a state-of-the-art compression algorithm that surpasses those currently available in the ROOT framework, with the purpose of enabling substantial economic and operational gains (including speedup) for High Energy and Nuclear Physics data storage/analysis. In our initial studies, a factor of nearly x4 (3.9) compression was achieved with RHIC/STAR data where ROOT compression managed only x1.4.In this contribution, we will present our concepts of “functionally lossless compression”, have a glance at examples and achievements in other communities, present the results and outcome of our current, ongoing R&D, as well as present a high-level view of our plan to move forward with a ROOT implementation that would deliver a basic solution readily integrated into HENP applications. As a collaboration of experimental scientists, private industry, and the ROOT Team, our aim is to capitalize on the substantial success delivered by the initial effort and produce a robust technology properly packaged as an open-source tool that could be used by virtually every experiment around the world as means for improving data management and accessibility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Purity monitoring for ProtoDUNE-SP

The Deep Underground Neutrino Experiment is a next-generation long-baseline neutrino oscillation experiment based on liquid argon time projection chamber technology. DUNE-s single-phase prototype ProtoDUNE-SP at CERN finished its two-year Phase-1 running in July 2021, successfully collected test-beam and cosmic ray data. A key aspect of LArTPC calibration is the lifetime of drift electrons. A purity monitor is a miniature TPC measuring the lifetime of electrons generated from the photocathode via the photoelectric effect. It enables continuous monitoring of the detector status, especially when filling the cryostat and when liquid argon recirculation systems operate. The purity monitoring system in ProtoDUNE-SP Phase-1 monitored liquid argon purity throughout its entire lifetime. It is essential to the experiment’s successful commissioning, operation, and data taking. This poster discusses the design, implementation, and results of purity monitors and plans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-252: On the Evaluation of Patient Specific IMRT QA Using EPID, Dynalog Files and Patient Anatomy

Purpose: This research, investigates the viability of using the Electronic portal imaging device (EPID) coupled with the treatment planning system (TPS), to calculate the doses delivered and verify agreement with the treatment plan. The results of QA analysis using the EPID, Delta4 and fluence calculations using the multi-leaf collimator (MLC) dynalog files on 10 IMRT patients are presented in this study. Methods: EPID Fluence Images in integrated mode and Dynalog files for each field were acquired for 10 IMRT (6MV) patients and processed through an in house MatLab program to create an opening density matrix (ODM) which was used as the input fluence for dose calculation with the TPS (Pinnacle3, Philips). The EPID used in this study was the aSi1000 Varian on a Novalis TX linac equipped with high definition MLC. The resulting dose distributions were then exported to VeriSoft (PTW) where a 3D gamma was calculated using 3mm-3% criteria. The Scandidos Delta4 phantom was also used to measure a 2D dose distribution for all 10 patients and a 2D gamma was calculated for each patient using the Delta4 software. Results: The average 3D gamma for all 10 patients using the EPID images was 98.2% ± 2.6%. The average 3D gamma using the dynalog files was 94.6% ± 4.9%. The average 2D gamma from the Delta4 was 98.1% ± 2.5%. The minimum 3D gamma for the EPID and dynalog reconstructed dose distributions was found on the same patient which had a very large PTV, requiring the jaws to open to the maximum field size. Conclusion: Use of the EPID, combined with a TPS is a viable method for QA of IMRT plans. A larger ODM size can be implemented to accommodate larger field sizes. An adaptation of this process to Volumetric Arc Therapy (VMAT) is currently under way.

60 APPLIED LIFE SCIENCES↗

SU-E-T-317: Dosimetric Evaluation of Acuros XB Advanced Dose Calculation Algorithm in Head and Neck Patients

Purpose: The Acuros XB photon dose calculation algorithm is a newly implemented calculation technique within the Eclipse treatment planning system using deterministic solutions to the linear Boltzmann transport equations. The goal of this study is to assess the clinical impact of dose differences arising from a retrospective comparison of calculations performed using the Analytical Anisotropic Algorithm (AAA) and Acuros XB on patients. Methods: Ten head and neck patients receiving intensity modulated radiation therapy were selected as a pilot study. Initial evaluation was based on the percentage of the planning target volume (PTV) covered by the prescription dose, minimum dose within the PTV, and dose differences in critical structures. For patients receiving boost plans, dosimetric evaluations were performed on the plan sum of the primary and boost plans. Results: Among the ten patients there were a total of 21 PTVs corresponding to primary and boost volumes. Using the same normalization within Eclipse, the average percentage of the PTVs receiving the prescription dose were 95.6% for AAA and Acuros XB. The average minimum doses within the PTVs, expressed as a percentage of the prescription to the volume, were 82.3% and 83.6% for AAA and Acuros XB respectively. Neither comparison showed differences with statistical significance when subjected to a paired t-test. Statistical significance was found in the average difference of the maximum dose for the mandible (242.5cGy, p=0.0005) and cord with a 5mm radial expansion (105.0cGy, p=0.0005) and in the median dose for the left parotid (25.0cGy, p=0.0423) and oral cavity (36.3cGy, p=0.002). Conclusion: The Acuros XB dose calculation algorithm did not exhibit significant differences in PTV coverage when compared to the AAA algorithm. Significant differences in critical structures are likely attributed to the structures proximity to high atomic number materials or air cavities, regions of known difficulty for the AAA algorithm.

60 APPLIED LIFE SCIENCES↗

SU-D-BRA-02: Motion Assessment During Open Face Mask SRS Using CBCT and Surface Monitoring

Purpose: To assess the robustness of immobilization using open-face mask technology for linac-based stereotactic radiosurgery (SRS) with multiple non-coplanar arcs via repeated CBCT acquisition, with comparison to contemporaneous optical surface tracking data. Methods: 25 patients were treated in open faced masks with cranial SRS using 3–4 non-coplanar arcs. Repeated CBCT imaging was performed to verify the maintenance of proper patient positioning during treatment. Initial patient positioning was performed based on prescribed shifts and optical surface tracking. Positioning refinements employed rigid 3D-matching of the planning CT and CBCT images and were implemented via automated 6DOF couch control. CBCT imaging was repeated following the treatment of all non-transverse beams with associated couch kicks. Detected patient translations and rotations were recorded and automatically corrected. Optical surface tracking was applied throughout the treatments to monitor motion, and this contemporaneous patient positioning data was recorded to compare against CBCT data and 6DOF couch adjustments. Results: Initial patient positions were refined on average by translations of 3±1mm and rotations of ±0.9-degrees. Optical surface tracking corroborated couch corrections to within 1±1mm and ±0.4-degrees. Following treatment of the transverse and subsequent superior-oblique beam, average translations of 0.6±0.4mm and rotations of ±0.4-degrees were reported via CBCT, with optical surface tracking in agreement to within 1.1±0.6mm and ±0.6-degrees. Following treatment of the third beam, CBCT indicated additional translations of 0.4±0.2mm and rotations of ±0.3-degrees. Cumulative couch corrections resulted in 0.7 ± 0.4mm average magnitude translations and rotations of ±0.4-degrees. Conclusion: Based on CBCT measurements of patients during SRS, the open face mask maintained patient positioning to within 1.5mm and 1-degree with >95% confidence. Patient positioning determined by optical surface tracking agreed with CBCT assessment to within 1±1mm and ±0.6-degree rotations. These data support the use of 1–2mm PTV margins and repeated CBCT to maintain stereotactic positioning tolerances.

60 APPLIED LIFE SCIENCES↗

SU-F-P-04: Implementation of Dose Monitoring Software: Successes and Pitfalls

Purpose: to successfully install a dose monitoring software (DMS) application to assist in CT protocol and dose management. Methods: Upon selecting the DMS, we began our implementation of the application. A working group composed of Medical Physics, Radiology Administration, Information Technology, and CT technologists was formed. On-site training in the application was supplied by the vendor. The decision was made to apply the process for all the CT protocols on all platforms at all facilities. Protocols were painstakingly mapped to the correct masters, and the system went ‘live’. Results: We are routinely using DMS as a tool in our Clinical Performance CT QA program. It is useful in determining the effectiveness of revisions to existing protocols, and establishing performance baselines for new units. However, the implementation was not without difficulty. We identified several pitfalls and obstacles which frustrated progress. Including: Training deficiencies, Nomenclature problems, Communication, DICOM variability. Conclusion: Dose monitoring software can be a potent tool for QA. However, implementation of the program can be problematic and requires planning, organization and commitment.

60 APPLIED LIFE SCIENCES↗

SU-F-T-204: A Preliminary Approach of Reducing Contralateral Breast and Heart Dose in Left Sided Whole Breast Cancer Patients Utilizing Proton Beams

Purpose: To investigate the plan quality and feasibility of a hybrid plan utilizing proton and photon fields for superior coverage in the internal mammary (IM) and supraclavicular (S/C) regions while minimizing heart and contralateral breast dose for the left-sided whole breast cancer patient treatment. Methods: This preliminary study carried out on single left-sided intact breast patient involved IM and S/C nodes. The IM and S/C node fields of the 5-Field 3DCRT photon-electron base plan were replaced by two proton fields. These two along with two Field-in-Field tangential photon fields were optimized for comparable dose coverage. The treatment plans were done using Eclipse TPS for the total dose of 46Gy in 23 fractions with 95% of the prescription dose covering 95% of the RTOG PTV. The 3DCRT photon-electron and 4-Field photon-proton hybrid plans were compared for the PTV dose coverage as well as dose to OARs. Results: The overall RTOG PTV coverage for proton-hybrid and 3DCRT plan was comparable (95% of prescription dose covers 95% PTV volume). In proton-hybrid plan, 99% of IM volume received 100% dose whereas in 3DCRT only 77% received 100% dose. For S/C regions, 97% and 77% volume received 100% prescription dose in proton-hybrid and 3DCRT plans, respectively. The heart mean dose, V3Gy(%), and V5Gy(%) was 2.2Gy, 14.4%, 9.8% for proton-hybrid vs. 4.20 Gy, 21.5%, and 39% for 3DCRT plan, respectively. The maximum dose to the contralateral breast was 39.75Gy for proton-hybrid while 56.87Gy for 3DCRT plan. The mean total lung dose, V20Gy(%), and V30Gy(%) was 5.68Gy, 11.3%, 10.5% for proton-hybrid vs. 5.90Gy, 9.8%, 7.2% for 3DCRT, respectively. Conclusion: The protonhybrid plan can offer better dose coverage to the involved lymphatic tissues while lower doses to the heart and contralateral breast. More treatment plans are currently in progress before being implemented clinically.

60 APPLIED LIFE SCIENCES↗

Evaluating a Transition-jump System for the Fermilab Main Injector Using Xsuite

We describe an Xsuite simulation framework for the Fermilab Main Injector (MI) along with an evaluation of transition-crossing behaviors in the accelerator. In particular, we studied the introduction of quadrupole magnets into the lattice as part of a transition-jump system that will be implemented through the $2^{nd}$ Proton Improvement Plan (PIP-II). Simulated beam losses spurred by transition-induced instabilities were assessed under several systematic effects, including MI quad errors, magnet-to-magnet variability in the jump magnets, power-supply errors, and timing jitter.

Schreckenberger, A. P. [Fermilab] (ORCID:000000016↗

Simulating Aftershocks for an On Site Inspection (OSI) Exercise

The experience of IFE14 emphasizes the need for a better way to simulate aftershocks during an OSI exercise. The obvious approach is to develop a digital model of aftershocks that can be used either for a real field exercise or for a computer simulation that can be done in an office, for training for example. However, this approach involves consideration of several aspects, such as how and when to introduce waveforms in a way that maximizes the realism of the data and that will be convincing to a savvy, experienced seismic analyst. The purpose of this report is to outline a plan for how this approach can be implemented.

58 GEOSCIENCES↗

NA84 Final Report: Initial Transition of the Optimization Planning Tool for Urban Search (OPTUS) to the AVID Operational Environment

The long-term objective of this project is to transition the OPTUS software into operational use. In FY2017, the LLNL/RSL project team identified an initial capability, compatible with the NA-84 operational software environment, that OPTUS could provide to assist search planning. The LLNL development team developed and implemented a solution to the problem and demonstrated the software utility to RSL. The enhanced OPTUS code was made available to RSL for evaluation. Although the project was not continued in FY18, a small amount of funding was carried over to support the handoff to RSL and to complete the FY17 annual report. The current report is a slight modification of the FY17 report and constitutes the final project report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Application of the Combined Judgmental and Randomly Placed Sampling Method

In the wake of the 2001 anthrax incidents in the United States, there has been considerable discussion about the role of judgmental and probabilistic sampling strategies, particularly in the context of clearance sampling. The Combined Judgmental and Random (CJR) methodology provides a statistical methodology that allows practitioners to leverage information from both judgmental and randomly selected sample locations and then quantify the confidence in negative results. The objective of the CJR sampling design is to demonstrate, with high probability, that a high percentage of the decision area (or population) is acceptable, given that none of the samples are unacceptable. The purpose of this document is to assist practitioners to appropriately use the CJR methodology and to implement this sampling design in Visual Sample Plan (VSP). We begin by defining some fundamental terms. A decision area is the geographical or spatial area (indoor or outdoor) about which practitioners wish to draw a conclusion on the basis of sampling and other relevant information. Decision areas typically include all or part of a building, but they may be any contaminated (or potentially contaminated) area for which characterization or clearance is required. In this report, a statistical sampling approach refers to any sampling approach based on a mathematical or statistical model that provides confidence or probability statements about the decision area. Statistical sampling approaches typically involve taking samples at random locations, or at the nodes of a randomly located grid or lattice that is superimposed on the decision area. The term probabilistic sampling is often used to describe statistical sampling designs that exclusively use randomly located samples. This terminology implies that probabilistic statements can only be made based upon the results of randomly placed samples. However, the CJR method utilizes a Bayesian model that gives rise to a formal probabilistic statement regarding the acceptability of the decision area based upon the information obtained from both judgmental and random samples. Judgmental samples play a vital role in the characterization and clearance process because they include the informed prior belief and expert knowledge of personnel involved in the sampling process.

97 MATHEMATICS AND COMPUTING↗

Fit for Purpose? The U.S. Nuclear Posture in 2030 and Beyond (Workshop Summary)

On June 8-10, the Center for Global Security Research (CGSR) at Lawrence Livermore National Laboratory (LLNL) hosted a workshop titled “Fit for Purpose? The U.S. Nuclear Posture in 2030 and Beyond.” This session brought together participants drawn across the policy, military, and technical communities. The workshop aimed to examine the existing modernization plans, the challenges that might obstruct their implementation, and the new deterrence requirements that might emerge in the future, in light of the modernization efforts of Russia and China.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Structural Characterization of Potential Carbon Dioxide Reservoirs and Adjacent Strata within the Llandovery Silurian to Middle Devonian Strata of Ohio

The Midwest Regional Carbon Sequestration Partnership (MRCSP) has incorporated the work of geologic research teams (Geoteams) in its regional characterization, project planning and carbon dioxide (CO 2 ) injection implementation work since the partnership was established by the U.S. Department of Energy (DOE) in 2003. Over this 16-year period, the cohort of Geoteams has grown from five to ten states and has contributed to the characterization of geologic sequestration opportunities, refinement of reservoir and seal data, and supported injection efforts through both predictive and post-injection assessments. This report details the work led by the Ohio Department of Natural Resources, Division of Geological Survey to evaluate the structure of nine formations in the Appalachian Basin of Ohio to assess seal integrity and whether carbon dioxide (CO 2 ) migration pathways could pose a potential risk. As part of Phase II MRCSP work, the Pennsylvania Geological Survey led the characterization of the Llandovery Silurian (“middle Silurian”) to Middle Devonian regional geologic characterization CO 2 utilization and storage. This preliminary assessment included generalized, regional-scale mapping, as well as the development of relatively coarse structure and isochore maps of stratigraphic intervals of interest for the Appalachian Basin. Because this stratigraphic interval offers several enhanced oil recovery targets and secondary targets for CO 2 storage, the Ohio Geological Survey undertook efforts in Phase III to characterize the Ohio’s portion of the Appalachian Basin more precisely and to resolve inconsistencies within Ohio’s formation tops. This study refined the subsurface correlations of the Silurian-through-Devonian stratigraphic section in Ohio. Higher-resolution isochore mapping of the CO 2 storage reservoirs and seals provides greater detail of potential high-porosity zones and potential structural influence on the interval.

01 COAL, LIGNITE, AND PEAT↗

Regional Geologic Cross Sections for Potential Storage and Containment Zones in the MRCSP Region

The Midwest Regional Carbon Sequestration Partnership (MRCSP) has incorporated the work of geologic research teams (Geoteams) in its regional characterization, project planning and carbon dioxide (CO 2 ) injection implementation work since the partnership was established by the U.S. Department of Energy (DOE) in 2003. Over this 16-year period, the cohort of Geoteams has grown from five to ten states and has contributed to the characterization of geologic sequestration opportunities, refinement of reservoir and seal data, and supported injection efforts through both predictive and post-injection assessments. Five geologic cross sections (labeled A through E) were constructed onshore across the parts of the MRCSP Region west of the Valley and Ridge Province, and one section (labeled F) was constructed beginning onshore in New Jersey and running eastward to offshore areas examined for carbon storage. Regional and local stratigraphic units were used in these cross sections to show current nomenclature as well as highlighting specific units/features pertinent to carbon capture, utilization and storage (CCUS) opportunities in the region. Each cross section uses 15 to 25 deep wells and other geologic information to illustrate the relative depth, thickness and location of rock units in the subsurface.

01 COAL, LIGNITE, AND PEAT↗

Assessment of Enhanced Oil Recovery Using Carbon Dioxide in Michigan Basin Silurian Pinnacle Reefs

The Midwest Regional Carbon Sequestration Partnership (MRCSP) has incorporated the work of geologic research teams (Geoteams) in its regional characterization, project planning and carbon dioxide (CO 2 ) injection implementation work since the partnership was established by the U.S. Department of Energy (DOE) in 2003. Over this 16-year period, the cohort of Geoteams has grown from five to ten states and has contributed to the characterization of geologic sequestration opportunities, refinement of reservoir and seal data, and supported injection efforts through both predictive and post-injection assessments. The Michigan team at Western Michigan University has provided technical analysis and support of the enhanced oil recovery (EOR) using carbon dioxide (CO 2 ) in the Northern Michigan Silurian Pinnacle reefs. With Core Energy, LLC as the industry partner, this project has assessed the potential for EOR in known fields in the Michigan Pinnacle reefs and the capacity for CO2 storage in the reef reservoirs as they are depleted and after reservoir abandonment. This project managed by Core Energy, LLC, involves the only commercial CO 2 Enhanced Oil Recovery floods within the MRCSP region. The Silurian pinnacle reef trend shows significant potential for CO 2 -EOR: this play is relatively new, with approximately 60% of the wells in the largest Niagaran fields still accessible. Most wells have modern logs and there are many cores, core analyses, pressure tests and produced water analyses available for study from these fields. These carbonate reservoirs in Michigan have produced sufficient oil to warrant evaluation for additional recovery efforts. The role of the Michigan team was to collect and analyze all relevant data about reservoir properties, including lithologic and depositional characteristics of the reservoir formations and porosity and fluid flow properties through different compartments in the reservoir. The team has also developed models that represent the geological and physical characteristics of the reservoir and seal system.

01 COAL, LIGNITE, AND PEAT↗

Physics Opportunities at a Beam Dump Facility at PIP-II at Fermilab and Beyond

The Fermilab Proton-Improvement-Plan-II (PIP-II) is being implemented in order to support the precision neutrino oscillation measurements at the Deep Underground Neutrino Experiment, the U.S. flagship neutrino experiment. The PIP-II LINAC is presently under construction and is expected to provide 800~MeV protons with 2~mA current. This white paper summarizes the outcome of the first workshop on May 10 through 13, 2023, to exploit this capability for new physics opportunities in the kinematic regime that are unavailable to other facilities, in particular a potential beam dump facility implemented at the end of the LINAC. Various new physics opportunities have been discussed in a wide range of kinematic regime, from eV scale to keV and MeV. We also emphasize that the timely establishment of the beam dump facility at Fermilab is essential to exploit these new physics opportunities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating a Transition-Jump System for the Fermilab Main Injector Using Xsuite

We describe an Xsuite simulation framework for the Fermilab Main Injector (MI) along with an evaluation of transition-crossing behaviors in the accelerator. In particular, we studied the introduction of quadrupole magnets into the lattice as part of a transition-jump system that will be implemented through the $2^{nd}$ Proton Improvement Plan (PIP-II). Simulated beam losses spurred by transition-induced instabilities were assessed under several systematic effects, including MI quad errors, magnet-to-magnet variability in the jump magnets, power-supply errors, and timing jitter.

Schreckenberger, Adam Paul [Fermilab] (ORCID:00000↗

Remote sensing in Michigan for land resource management

This project to demonstrate the application of earth resource survey technology to current problems in Michigan was undertaken jointly by the Environmental Research Institute of Michigan and Michigan State University. Remote sensing techniques were employed to advantage in providing management information for the Pointe Mouillee State Game Area and preparing an impact assessment in advance of the projected construction of the M-14 freeway from Ann Arbor to Plymouth, Michigan. The project also assisted the state government in its current effort to develop and implement a state-wide land management plan.

Sattinger, I. J.↗