Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Conformal Brachytherapy Planning for Cervical Cancer Using Transabdominal Ultrasound

Purpose: To determine if transabdominal ultrasound (US) can be used for conformal brachytherapy in cervical cancer patients. Materials and Methods: Seventy-one patients with locoregionally advanced cervix cancer treated with chemoradiation and brachytherapy were included in this study. The protocol consisted of US-assisted tandem insertion and conformal US-based planning. Orthogonal films for applicator reconstruction were also taken. A standard plan was modified to suit the US-based volume and treatment was delivered. The patient then underwent a magnetic resonance imaging (MRI) scan with the applicators in situ. Retrospectively, individual standard (STD), US, and MRI plans were extrapolated for five fractions and superimposed onto the two-dimensional sagittal MRI images for comparison. Doses to Point A, target volume, International Commission on Radiation Units and Measurements (ICRU) 38 bladder and rectal points, and individualized bowel points were calculated on original implant geometry on Plato for each planning method. Results: STD (high-dose-rate) plans reported higher doses to Point A, target volume, ICRU 38 bladder and rectal points, and individualized bowel point compared with US and MRI plans. There was a statistically significant difference between standard plans and image-based plans-STD vs. US, STD vs. MRI, and STD vs. Final-having consistent (p {<=} 0.001) respectively for target volume, Point A, ICRU 38 bladder, and bowel point. US plan assessed on two-dimensional MRI image was comparable for target volume (p = 0.11), rectal point (p = 0.8), and vaginal mucosa (p = 0.19). Local control was 90%. Late bowel morbidity (G3, G4) was <2%. Conclusions: Transabdominal ultrasound offers an accurate, quick, accessible, and cost-effective method of conformal brachytherapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Outcomes Study of Proton Therapy for Chordomas and Chondrosarcomas of the Spine

Purpose: To evaluate the effectiveness of definitive or adjuvant external beam proton therapy on survival in patients with chordomas and chondrosarcomas of the spine. Methods and Materials: Between March 2007 and May 2013, 51 patients with a median age of 58 years (range, 22-83 years) with chordoma (n=34) or chondrosarcomas (n=17) of the sacrum (n=21), the cervical spine (n=20), and the thoracolumbar spine (n=10) were treated with external beam proton therapy to a median dose of 70.2 Gy(RBE) [range, 64.2-75.6 Gy(RBE)] at our institution. Distant metastases, overall survival, cause-specific survival, local control, and disease-free survival were calculated. Results: The mean follow-up time was 3.7 years (range, 0.3-7.7 years). Across all time points, 25 patients experienced disease recurrence: 18 local recurrences, 6 local and distant recurrences, and 1 distant metastasis. The 4-year rates of overall survival and cause-specific survival were 72%; disease-free survival was 57%, local control was 58%, and freedom from distant metastases was 86%. The median time to local progression was 1.7 years (range, 0.2-6.0 years), and the median time to distant progression was 1.6 years (range, 0.2-6.0 years). The risk factors for local recurrence were age ≤58 years (62% vs 26%; P=.04) and recurrence after prior surgery (29% vs 81%; P=.01). Secondary cancers developed in 2 patients: B-cell lymphoma 5.5 years after treatment and bladder cancer 2 years after treatment. We observed the following toxicities: sacral soft tissue necrosis requiring surgery (n=2), T1 vertebral fracture requiring fusion surgery (n=1), chronic urinary tract infections (n=1), surgery for necrotic bone cyst (n=1), and grade 2 bilateral radiation nephritis (n=1). Conclusion: High-dose proton therapy controls more than half of spinal chordomas and chondrosarcomas and compares favorably with historic photon data. Local progression is the dominant mode of treatment failure and may be reduced by treating patients at the time of initial diagnosis. The impact of age is a novel finding of this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptively driven X-ray diffraction guided by machine learning for autonomous phase identification

Machine learning (ML) has become a valuable tool to assist and improve materials characterization, enabling automated interpretation of experimental results with techniques such as X-ray diffraction (XRD) and electron microscopy. Because ML models are fast once trained, there is a key opportunity to bring interpretation in-line with experiments and make on-the-fly decisions to achieve optimal measurement effectiveness, which creates broad opportunities for rapid learning and information extraction from experiments. Here, we demonstrate such a capability with the development of autonomous and adaptive XRD. By coupling an ML algorithm with a physical diffractometer, this method integrates diffraction and analysis such that early experimental information is leveraged to steer measurements toward features that improve the confidence of a model trained to identify crystalline phases. We validate the effectiveness of an adaptive approach by showing that ML-driven XRD can accurately detect trace amounts of materials in multi-phase mixtures with short measurement times. The improved speed of phase detection also enables in situ identification of short-lived intermediate phases formed during solid-state reactions using a standard in-house diffractometer. Our findings showcase the advantages of in-line ML for materials characterization and point to the possibility of more general approaches for adaptive experimentation.

36 MATERIALS SCIENCE↗

Reinforcing multiwall carbon nanotubes by electron beam irradiation

We study the effect of electron beam irradiation on the bending modulus of multiwall carbon nanotubes grown by chemical vapor deposition. Atomic force microscopy observations of the nanotube deflection in the suspended-beam geometry suggest an internal, reversible stick-slip motion prior to irradiation, indicating presence of extended defects. Upon electron beam irradiation, nanotubes with an initial bending modulus exceeding 10 GPa initially get stiffer, before softening at high doses. Highly defective nanotubes with smaller initial bending moduli do not exhibit the initial reinforcement. These data are explained by ab initio molecular dynamics calculations suggesting a spontaneous cross-linking of neighboring nanotube walls at extended vacancy defects created by the electron beam, in agreement with electron microscopy observations. At low defect concentration, depending on the edge morphology, the covalent bonds between neighboring nanotube walls cause reinforcement by resisting relative motion of neighboring walls. At high concentration of defects that are present initially or induced by high electron beam dose, the structural integrity of the entire system suffers from increasing electron beam damage.

36 MATERIALS SCIENCE↗

Interaction between water and defective silica surfaces

We use the density functional theory method to study dry (1 x 1) {alpha}-quartz (0001) surfaces that have Frenkel-like defects such as oxygen vacancy and oxygen displacement. These defects have distinctively different effects on the water-silica interface depending on whether the adsorbent is a single water molecule, a cluster, or a thin film. The adsorption energies, bonding energies, and charge transfer or redistributions are analyzed, from which we find that the existence of a defect enhances the water molecule and cluster surface interaction by a large amount, but has little or even negative effect on water thin film-silica surface interaction. The origin of the weakening in film-surface systems is the collective hydrogen bonding that compromises the water-surface interaction in the process of optimizing the total energy. For clusters on surfaces, the lowest total energy states lower both the bonding energy and the adsorption energy.

36 MATERIALS SCIENCE↗

Nonequilibrium kinetics of the electron–phonon sybsystem of a crystal in a strong electric field as a base of the electroplastic effect

We present the results of a kinetic analysis of nonequilibrium dynamics of the electron–phonon system of a crystal in a strong electric field based on the proposed method of numerically solving a set of Boltzmann equations for electron and phonon distribution functions without expanding the electron distribution function into a series in the phonon energy. It is shown that the electric field action excites the electron subsystem, which by transferring energy to the phonon subsystem creates a large amount of short-wave phonons that effectively influence the lattice defects (point, lines, boundaries of different phases), which results in a redistribution of and decrease in the lattice defect density, in damage healing, in a decrease in the local peak stress, and a decrease in the degradation level of the construction material properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charged point defect benchmark of Hybrid and GGA-PBE

Data used by the publication "High-throughput calculations of charged point defect properties with semi-local density functional theory - performance benchmarks for materials screening applications." This work presented an in-depth benchmark analysis of automated, semi-local point defect calculations with a-posteriori corrections, compared to 245 “gold standard” hybrid calculations previously published. We considered three different a-posteriori correction sets for semi-local calculations, implemented in a fully automated workflow, and consider the qualitative and quantitative differences for four different categories of defect information: thermodynamic transition levels, formation energies, fermi levels, and dopability limits. We highlighted the type of qualitative information about point defect properties that can be extracted from high-throughput calculations based on semi-local DFT methods, while also demonstrating the limits of quantitative accuracy that can be achieved by these approaches.

Broberg, Danny↗

Computational Exploration of the Li-Electrode|Electrolyte Interface in the Presence of a Nanometer Thick Solid-Electrolyte Interphase Layer [Computational exploration of the Li-electrode|electrolyte interface complicated by a nanometer thin solid-electrolyte interphase (SEI) layer]

A nanometer thick passivation layer will spontaneously form on Li-metal in battery applications due to electrolyte reduction reactions. This passivation layer in rechargeable batteries must have “selective” transport properties: blocking electrons from attacking the electrolytes, while allowing Li + ion to pass through so the electrochemical reactions can continue. The classical description of the electrochemical reaction, Li + + e → Li 0 , occurring at the Li-metal|electrolyte interface is now complicated by the passivation layer and will reply on the coupling of electronic and ionic degrees of freedom in the layer. We consider the passivation layer, called “solid electrolyte interphase (SEI)”, as “the most important but the least understood in rechargeable Li-ion batteries,” partly due to the lack of understanding of its structure–property relationship. In predictive modeling, starting from the ab initio level, we find that it is an important tool to understand the nanoscale processes and materials properties governing the interfacial charge transfer reaction at the Li-metal|SEI|electrolyte interface. Here, we demonstrate pristine Li-metal surfaces indeed dissolve in organic carbonate electrolytes without the SEI layer. Based on joint modeling and experimental results, we point out that the well-known two-layer structure of SEI also exhibits two different Li + ion transport mechanisms. The SEI has a porous (organic) outer layer permeable to both Li + and anions (dissolved in electrolyte), and a dense (inorganic) inner layer facilitate only Li + transport. This two-layer/two-mechanism diffusion model suggests only the dense inorganic layer is effective at protecting Li-metal in electrolytes. This model suggests a strategy to deconvolute the structure–property relationships of the SEI by analyzing an idealized SEI composed of major components, such as Li 2 CO 3 , LiF, Li 2 O, and their mixtures. After sorting out the Li+ ion diffusion carriers and their diffusion pathways, we design methods to accelerate the Li + ion conductivity by doping and by using heterogonous structure designs. We will predict the electron tunneling barriers and connect them with measurable first cycle irreversible capacity loss. We note that the SEI not only affects Li + and e – transport, but it can also impose a potential drop near the Li-metal|SEI interface. Our challenge is to fully describe the electrochemical reactions at the Li - metal|SEI|electrolyte interface. This will be the subject of ongoing efforts.

30 DIRECT ENERGY CONVERSION↗

Three-Dimensional Imaging in Gynecologic Brachytherapy: A Survey of the American Brachytherapy Society

Purpose: To determine current practice patterns with regard to three-dimensional (3D) imaging for gynecologic brachytherapy among American Brachytherapy Society (ABS) members. Methods and Materials: Registered physician members of the ABS received a 19-item survey by e-mail in August 2007. This report excludes physicians not performing brachytherapy for cervical cancer. Results: Of the 256 surveys sent, we report results for 133 respondents who perform one or more implantations per year for locally advanced cervical cancer. Ultrasound aids 56% of physicians with applicator insertion. After insertion, 70% of physicians routinely obtain a computed tomography (CT) scan. The majority (55%) use CT rather than X-ray films (43%) or magnetic resonance imaging (MRI; 2%) for dose specification to the cervix. However, 76% prescribe to Point A alone instead of using a 3D-derived tumor volume (14%), both Point A and tumor volume (7%), or mg/h (3%). Those using 3D imaging routinely contour the bladder and rectum (94%), sigmoid (45%), small bowel (38%), and/or urethra (8%) and calculate normal tissue dose-volume histogram (DVH) analysis parameters including the D2cc (49%), D1cc (36%), D0.1cc (19%), and/or D5cc (19%). Respondents most commonly modify the treatment plan based on International Commission on Radiation Units bladder and/or rectal point dose values (53%) compared with DVH values (45%) or both (2%). Conclusions: More ABS physician members use CT postimplantation imaging than plain films for visualizing the gynecologic brachytherapy apparatus. However, the majority prescribe to Point A rather than using 3D image based dosimetry. Use of 3D image-based treatment planning for gynecologic brachytherapy has the potential for significant growth in the United States.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Pro-Qura Case Volume on Post-Implant Prostate Dosimetry

Purpose: To evaluate the effect of prostate brachytherapy case volume on postimplant dosimetric quality in Pro-Qura proctored programs. Methods and Materials: From August 1999 to December 2008, the computed tomography datasets for 6,600 prostate implants performed by 129 brachytherapists were submitted to Pro-Qura for dosimetric analysis. Brachytherapists were divided into three roughly equal-sized terciles based on total case volume. Postimplant computed tomography scans were obtained at a median of 30 days. Excellent target coverage was defined by a V100 {>=}90% and D90 {>=}100% minimum prescribed peripheral dose. To determine if the number of excellent implants improved with increasing case numbers, each brachytherapist's series of implants was bisected into early and late experience by a moveable critical point. Results: For the entire cohort, the mean V100 and D90 were 89.2% and 102.8%, respectively, with 47.7% of the implants scored as excellent. Brachytherapists in the highest-case tercile had a significantly greater fraction of excellent target coverage (57.9%) than did those in the two lower terciles (39.5% and 45.7%, p = 0.015). Twenty-one (25.6%) of the 82 brachytherapists with sufficient case volume for dosimetric improvement analyses demonstrated quality improvement over time. Although there was no significant difference between prostate volume and seed strength, the number of seeds used was significantly greater in adequate implants. Conclusions: The highest-volume brachytherapists were most likely to obtain excellent target coverage. We are encouraged that in general practice, nearly 48% of all implants were scored excellent. It is conceivable that with greater expert third-party involvement, an even greater percentage of cases with excellent target coverage will become reality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methane and carbon dioxide production from simulated anaerobic degradation of cattle carcasses

Highlights: Black-Right-Pointing-Pointer This study evaluates methane and carbon dioxide production after land burial of cattle carcasses. Black-Right-Pointing-Pointer Disposal of animal mortalities is often overlooked in evaluating the environmental impacts of animal production. Black-Right-Pointing-Pointer we quantify annual emissions from cattle carcass disposal in the United States as 1.6 Tg CO{sub 2} equivalents. - Abstract: Approximately 2.2 million cattle carcasses require disposal annually in the United States. Land burial is a convenient disposal method that has been widely used in animal production for disposal of both daily mortalities as well as during catastrophic mortality events. To date, greenhouse gas production after mortality burial has not been quantified, and this study represents the first attempt to quantify greenhouse gas emissions from land burial of animal carcasses. In this study, anaerobic decomposition of both homogenized and unhomogenized cattle carcass material was investigated using bench-scale reactors. Maximum yields of methane and carbon dioxide were 0.33 and 0.09 m{sup 3}/kg dry material, respectively, a higher methane yield than that previously reported for municipal solid waste. Variability in methane production rates were observed over time and between reactors. Based on our laboratory data, annual methane emissions from burial of cattle mortalities in the United States could total 1.6 Tg CO{sub 2} equivalents. Although this represents less than 1% of total emissions produced by the agricultural sector in 2009, greenhouse gas emissions from animal carcass burial may be significant if disposal of swine and poultry carcasses is also considered.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-599: The Variation of Hounsfield Unit and Relative Electron Density Determination as a Function of KVp and Its Effect On Dose Calculation Accuracy

Purpose: To investigate the differences in relative electron density for different energy (kVp) settings and the effect that these differences have on dose calculations. Methods: A Nuclear Associates 76-430 Mini CT QC Phantom with materials of known relative electron densities was imaged by one multi-slice (16) and one single-slice computed tomography (CT) scanner. The Hounsfield unit (HU) was recorded for each material with energies ranging from 80 to 140 kVp and a representative relative electron density (RED) curve was created. A 5 cm thick inhomogeneity was created in the treatment planning system (TPS) image at a depth of 5 cm. The inhomogeneity was assigned HU for various materials for each kVp calibration curve. The dose was then calculated with the analytical anisotropic algorithm (AAA) at points within and below the inhomogeneity and compared using the 80 kVp beam as a baseline. Results: The differences in RED values as a function of kVp showed the largest variations of 580 and 547 HU for the Aluminum and Bone materials; the smallest differences of 0.6 and 3.0 HU were observed for the air and lung inhomogeneities. The corresponding dose calculations for the different RED values assigned to the 5 cm thick slab revealed the largest differences inside the aluminum and bone inhomogeneities of 2.2 to 6.4% and 4.3 to 7.0% respectively. The dose differences beyond these two inhomogeneities were between 0.4 to 1.6% for aluminum and 1.9 to 2.2 % for bone. For materials with lower HU the calculated dose differences were less than 1.0%. Conclusion: For high CT number materials the dose differences in the phantom calculation as high as 7.0% are significant. This result may indicate that implementing energy specific RED curves can increase dose calculation accuracy.

60 APPLIED LIFE SCIENCES↗

Grid Operator Analytics and Assessment Tools for Inverter- Based Resources Dominated Grid (GOAAT-IBR) Project Update

This presentation provides an update on the OPTIMA GOAAT project, with emphasis on the cloud-native data platform developed in-house to ingest, manage, and operationalize high-resolution power system data. Since our last NASPI presentation, accessible via OSTI ID #2671437, the project team advanced the design and deployment of a scalable architecture capable of handling both synchronized and non-synchronized streams, including PMU, point-on-wave (POW), COMTRADE, and SCADA data. These materials review the project status, recent progress, and key lessons learned. The core of the presentation examines the architecture and engineering of our cloud-native ingestion and data management platform. We then explain how pipelines were designed to collect, normalize, time-align, store, and serve heterogeneous data at scale. We will discuss design choices such as data models, streaming versus batch ingestion, storage tiers, and interoperability with analytics applications. Practical experiences with cloud-native technologies were shared during the event, including benefits, limitations, and integration challenges in a utility environment, along with methods used to improve performance, reduce latency, and optimize resource usage. The presentation also showcases user interface designs and visualization tools that convert raw measurements and analytics results into intuitive, actionable insights for operators and engineers. During the presentation examples were provided demonstrating how visualization, event views, and summarized analytics enhance situational awareness and support operational decision-making. These use cases illustrate how a well-designed data infrastructure can bridge the gap between high-volume measurements and practical grid operations.

Aminifar, Farrokh↗

Estimates of Quantum Tunneling Effects for Hydrogen Diffusion in PuO 2

We detail the estimation of activation energies and quantum nuclear vibrational tunneling effects for hydrogen diffusion in PuO 2 based on Density Functional Theory calculations and a quantum double well approximation. We find that results are relatively insensitive to choice of exchange correlation functional. In addition, the representation of spin in the system and use of an extended Hubbard U correction has only a small effect on hydrogen point defect formation energies when the PuO 2 lattice is held fixed at the experimental density. We then compute approximate activation energies for transitions between hydrogen interstitial sites seeded by a semi-empirical quantum model and determine the quantum tunneling enhancement relative to classical kinetic rates. Our model indicates that diffusion rates in H/PuO 2 systems could be enhanced by more than one order of magnitude at ambient conditions and that these effects persist at high temperature. The method we propose here can be used as a fast screening tool for assessing possible quantum nuclear vibrational effects in any number of condensed phase materials and surfaces, where hydrogen hopping tends to follow well defined minimum energy pathways.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Co{sub 3}O{sub 4}-Co{sub 2}ZnO{sub 4} spinels: The case for a solid solution

In prior first-principles theoretical work we predicted a complete solid solution in the Co{sub 3}O{sub 4}-Co{sub 2}ZnO{sub 4} system, with a negligibly small mixing enthalpy. In this work we tested this prediction on bulk, large-grained specimens across the Co{sub 3}O{sub 4}-Co{sub 2}ZnO{sub 4} join, combining oxide melt solution calorimetry, differential scanning calorimetry, precise lattice parameter measurements, anomalous X-ray and neutron diffraction, and in situ electrical measurements. The calorimetric results confirm the presence of a solid solution at high temperatures, but with a large enthalpy of mixing that exceeds the predicted value. Because Co{sub 3}O{sub 4} and Co{sub 2}ZnO{sub 4} have essentially identical lattice parameters, this energetic destabilization must arise from factors other than the strain energy resulting from size mismatch. Changes in Co{sup 3+} spin states vs. temperature and zinc content are proposed to account for the positive excess enthalpy, and may also provide additional entropy to stabilize the solid solution at high temperature. - Graphical abstract: The first-principles theoretical prediction of a complete solid solution in Co{sub 3}O{sub 4}-Co{sub 2}ZnO{sub 4} spinels has been confirmed experimentally by calorimetric, structural, and electrical measurements. The large mixing enthalpy observed exceeds the predicted value and cannot be accounted for by strain or cation distribution contributions alone, since such effects are small in this system; instead, changes in the spin state of Co{sup 3+} are proposed to account for the mixing thermodynamics. Highlights: Black-Right-Pointing-Pointer Experiments confirm theory prediction of a solid solution in Co{sub 3}O{sub 4}-Co{sub 2}ZnO{sub 4} spinels. Black-Right-Pointing-Pointer Thermodynamics of mixing studied by calorimetric, electrical, structural methods. Black-Right-Pointing-Pointer Cation distributions found to be mostly normal for various compositions. Black-Right-Pointing-Pointer Mixing enthalpy is larger than prediction and inconsistent with strain effects. Black-Right-Pointing-Pointer Changes in Co{sup 3+} spin state proposed as source of large mixing enthalpy/entropy.

36 MATERIALS SCIENCE↗

Synthesis of porous sheet-like Co{sub 3}O{sub 4} microstructure by precipitation method and its potential applications in the thermal decomposition of ammonium perchlorate

Porous sheet-like cobalt oxide (Co{sub 3}O{sub 4}) were successfully synthesized by precipitation method combined with calcination of cobalt hydroxide precursors. The structure, morphology and porosity properties of the products were characterized by X-ray powder diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and nitrogen adsorption-desorption measurement. The as-prepared sheet-like microstructures were approximately 2-3 {mu}m in average diameter, and the morphology of the cobalt hydroxide precursors was retained after the calcination process. However, it appeared a large number of uniform pores in the sheets after calcination. In order to calculate the potential catalytic activity, the thermal decomposition of ammonium perchlorate (AP) has been analyzed, in which cobalt oxide played a role of an additive and the porous sheet-like Co{sub 3}O{sub 4} microstructures exhibited high catalytic performance and considerable decrease in the thermal decomposition temperature of AP. Moreover, a formation mechanism for the sheet-like microstructures has been discussed. - Graphical abstract: Porous sheet-like Co{sub 3}O{sub 4} were synthesized by facile precipitation method combined with calcination of {beta}-Co(OH){sub 2} precursors. Thermogravimetric-differential scanning calorimetric analysis indicates potential catalytic activity in the thermal decomposition of ammonium perchlorate. Highlights: Black-Right-Pointing-Pointer Synthesis of sheet-like {beta}-Co(OH){sub 2} precursors by precipitation method. Black-Right-Pointing-Pointer Porous sheet-like Co{sub 3}O{sub 4} were obtained by calcining {beta}-Co(OH){sub 2} precursors. Black-Right-Pointing-Pointer The possible formation mechanism of porous sheet-like Co{sub 3}O{sub 4} has been discussed. Black-Right-Pointing-Pointer Porous sheet-like Co{sub 3}O{sub 4} decrease the thermal decomposition temperature of ammonium perchlorate.

36 MATERIALS SCIENCE↗

Decoding defect statistics from diffractograms via machine learning

Abstract Diffraction techniques can powerfully and nondestructively probe materials while maintaining high resolution in both space and time. Unfortunately, these characterizations have been limited and sometimes even erroneous due to the difficulty of decoding the desired material information from features of the diffractograms. Currently, these features are identified non-comprehensively via human intuition, so the resulting models can only predict a subset of the available structural information. In the present work we show (i) how to compute machine-identified features that fully summarize a diffractogram and (ii) how to employ machine learning to reliably connect these features to an expanded set of structural statistics. To exemplify this framework, we assessed virtual electron diffractograms generated from atomistic simulations of irradiated copper. When based on machine-identified features rather than human-identified features, our machine-learning model not only predicted one-point statistics (i.e. density) but also a two-point statistic (i.e. spatial distribution) of the defect population. Hence, this work demonstrates that machine-learning models that input machine-identified features significantly advance the state of the art for accurately and robustly decoding diffractograms.

36 MATERIALS SCIENCE↗

Specific features of electronic and vibrational properties of I-V-V{sub 2} crystals

The ab initio density functional method with using pseudopotentials has been applied to calculate the electronic and vibrational spectra of the LiN{sub 2} and NaPN{sub 2} crystals, with optimization of their structure. The specific features of the crystal structure (highly compressed chalcopyrite) and composition of these crystals manifest themselves in the qualitative similarity of their band spectra and chemical bonding to those of chalcopyrite as well as in some substantial distinctions. The second valence band exhibits four branches instead of two branches, as in chalcopyrite crystals, and involves contributions of the p-states of the P and N atoms rather than the s states of the Group-III cations in the I-III-VI{sub 2} chalcopyrite compounds. The top of the valence band is at the side points of the Brillouin zone, the bottom of the conduction band is in the center of the Brillouin zone, and the absorption edge corresponds to the indirect band gap. The contributions of alkali metals to the vibration spectra are significant in the region of low-frequency modes; phosphorus and nitrogen make significant contributions to the modes in the high-frequency region, which is due to the prominent covalent component of bonding between these atoms.

36 MATERIALS SCIENCE↗