Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

NASA's program in lidar remote sensing

Several major NASA research efforts in lidar remote sensing are reviewed, with attention given to hardware and key sensor issues along with results and expectations. The discussion covers temperature and pressure measurements, measurements methods and instrumentation, pressure data, wind field measurements, atmospheric backscatter measurement, aerosol and cloud measurements, and water vapor measurement. Consideration is also given to the applicability of lidar measurements to problems of operational weather analysis and forecasting, climate studies, mesoscale and severe storm analysis and forecastig, and studies of atmosphere/surface interface.

Theon, John S.↗

Detailed Modeling and Analysis of the CPFM Dataset

A quantitative understanding of photolysis rate coefficients (or "j-values") is essential to determining the photochemical reaction rates that define ozone loss and other crucial processes in the atmosphere. j-Values can be calculated with radiative transfer models, derived from actinic flux observations, or inferred from trace gas measurements. The principal objective of this study is to cross-validate j-values from the Composition and Photodissociative Flux Measurement (CPFM) instrument during the Photochemistry of Ozone Loss in the Arctic Region In Summer (POLARIS) and SAGE I11 Ozone Loss and Validation Experiment (SOLVE) field campaigns with model calculations and other measurements and to use this detailed analysis to improve our ability to determine j-values. Another objective is to analyze the spectral flux from the CPFM (not just the j-values) and, using a multi-wavelength/multi-species spectral fitting technique, determine atmospheric composition.

Swartz, William H.↗

A Dynamic PCA and Machine Learning Tool for Automated Identification of Solar Wind Disturbances Impacting Earth’s Magnetosphere

Earth’s magnetosphere is continuously impacted by solar wind and interplanetary magnetic field (IMF) disturbances, such as shocks, discontinuities, magnetic clouds and more. Understanding how such disturbances propagate from the Sun and what is their impact on the different magnetospheric domains is key to understanding and forecasting energy transfer from the solar wind to Earth. The large number of overlapping solar wind and magnetospheric missions carrying magnetometers and the recent advances in communications and data storage technologies have enabled an unprecedented quantity of high-fidelity magnetic field data captured by in-situ spacecraft to be available at the click of a button. However, this massive quantity of available data can prove unwieldy for researchers, limiting the identification of interesting phenomena and disturbances to a relatively small percentage of the total dataset. Several techniques have been previously developed for automated identification of specific types of magnetic anomalies, but these methods are typically mission-specific and can be difficult to generalize. We present initial results for a generic method of automated anomaly detection in magnetic field measurements based on dimensionality reduction and unsupervised clustering via machine learning. The benefit of our technique is its high degree of generalizability and flexibility which make it a most useful data survey tool for a wide range of magnetic field datasets. This method can also be applied simultaneously to other observed time-series properties like plasma density, pressure, and velocity for more accurate event identification. Additionally, the application of this method to data captured by multiple spacecraft enables the simultaneous identification of disturbances and the determination of their propagation characteristics. Initial evaluation of this technique has been performed using data from Magnetospheric MultiScale (MMS) and THEMIS-ARTEMIS missions, providing a testbed scenario for the future Heliophysics Environmental and Radiation Measurement Experiment Suite (HERMES) platform instruments that will measure solar wind and IMF properties from lunar orbit onboard the Gateway station.

Miguel Martinez-Ledesma↗

A Dynamic PCA and Machine Learning Tool for Automated Identification of Solar Wind Disturbances Impacting Earth’s Magnetosphere

Earth’s magnetosphere is continuously impacted by solar wind and interplanetary magnetic field (IMF) disturbances, such as shocks, discontinuities, magnetic clouds and more. Understanding how such disturbances propagate from the Sun and what is their impact on the different magnetospheric domains is key to understanding and forecasting energy transfer from the solar wind to Earth. The large number of overlapping solar wind and magnetospheric missions carrying magnetometers and the recent advances in communications and data storage technologies have enabled an unprecedented quantity of high-fidelity magnetic field data captured by in-situ spacecraft to be available at the click of a button. However, this massive quantity of available data can prove unwieldy for researchers, limiting the identification of interesting phenomena and disturbances to a relatively small percentage of the total dataset. Several techniques have been previously developed for automated identification of specific types of magnetic anomalies, but these methods are typically mission-specific and can be difficult to generalize. We present initial results for a generic method of automated anomaly detection in magnetic field measurements based on dimensionality reduction and unsupervised clustering via machine learning. The benefit of our technique is its high degree of generalizability and flexibility which make it a most useful data survey tool for a wide range of magnetic field datasets. This method can also be applied simultaneously to other observed time-series properties like plasma density, pressure, and velocity for more accurate event identification. Additionally, the application of this method to data captured by multiple spacecraft enables the simultaneous identification of disturbances and the determination of their propagation characteristics. Initial evaluation of this technique has been performed using data from Magnetospheric MultiScale (MMS) and THEMIS-ARTEMIS missions, providing a testbed scenario for the future Heliophysics Environmental and Radiation Measurement Experiment Suite (HERMES) platform instruments that will measure solar wind and IMF properties from lunar orbit onboard the Gateway station.

Miguel Martinez-Ledesma↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Humidified single-scattering albedometer (H-CAPS-PM SSA ): Design, data analysis, and validation

In this work, we report the development and validation of a new humidified aerosol single-scattering albedometer to quantify the effects of water uptake on submicrometer particle optical properties. The instrument simultaneously measures in situ aerosol light extinction ( σ ep ) and scattering ( σ sp ) using a cavity-attenuated phase shift-single scattering albedo particulate matter (PM) monitor (CAPS-PM SSA , Aerodyne Research, Inc., Billerica, MA, USA). It retrieves by difference aerosol light absorption ( σ ap ) and directly quantifies aerosol single-scattering albedo (SSA), the aerosol “brightness.” We custom built a relative humidity (RH) control system using a water vapor-permeable membrane humidifier and coupled it to the CAPS-PM SSA to enable humidified aerosol observations. Our humidified instrument (H-CAPS-PM SSA ) overcomes problems with noise caused by mirror purge-flow humidification, heating, and characterizing cell RH. Careful angular truncation corrections in scattering, particularly for larger particles, were combined with empirical observations. Results show that the optimal operational size to be D p < 400 nm. The H-CAPS-PM SSA was evaluated with several pure single-component aerosols including ammonium sulfate ((NH 4 ) 2 SO 4 ), absorbing nigrosin, and levoglucosan, an organic biomass smoke tracer. The measured σ ep , σ sp , and the derived optical hygroscopicity parameter ( κ ) for size-selected ammonium sulfate are in good agreement with literature values. For dry size-selected nigrosin in the 100 < D p < 400 nm range, SSA values increased from ~0.3 to 0.65 with increasing D p . The enhancement in nigrosin σ ap at RH = 80% was a factor of 1.05–1.20 relative to dry conditions, with the larger particles showing greater enhancement. SSA increased with RH with the largest fractional enhancement measured for the smallest particles. For polydisperse levoglucosan, we measured an optical κ of 0.26 for both light extinction and scattering and negligible absorption. Our new instrument enables reliable observations of the effects of ambient humidity on mixed aerosol optical properties, particularly for light-absorbing aerosols whose climate forcing is uncertain due to measurement gaps.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric and spectroscopic research in the far infrared

The University of Oregon (UO) has been a major participant in the development of far infrared spectroscopic research of the stratosphere for the purpose of understanding the ozone layer processes. The UO has had a 15-year collaboration with the Italian group of B. Carli, and have participated in the 1978/79 Sub-millimeter Infrared Balloon Experiment (SIBEX), in the Balloon Intercomparison Campaign, (BIC), in the Infrared Balloon Experiment (IBEX), and in the recently concluded Far Infrared Experiment for UARS Correlative Measurements (FIREX). Both IBEX and FIREX programs were conducted in collaboration with NASA Langley, and were designed as validation flights in support of the Upper Atmosphere Research Satellite (UARS) Program. The technique of atmospheric far infrared spectroscopy offers two important advantages. First, many chemically important species can be measured simultaneously and co-spatially in the atmosphere. Second, far infrared atmospheric spectra can be obtained in thermal emission without reference to the sun's position, enabling full diurnal and global coverage. Recent improvements in instrumentation, field measurements, and molecular concentration retrieval techniques are now making the far infrared a mature measurement technology. This work to date has largely focused on balloon-based studies, but the future efforts will focus also on satellite-based experiments. A program of research in the following general areas was proposed: Laboratory Pressure broadening coefficient studies; specialized detector system assembly and testing; and consultation and assistance with instrument and field support. The proposal was approved and a three-year research grant titled 'Atmospheric and Spectroscopic Research in the Far Infrared' was awarded. A summary of technical accomplishments attained during the grant period are presented.

Park, Kwangjai↗

Measurements of supersonic jet aircraft wakes in the stratosphere

Progress is reported in an experimental program consisting of making supersonic aircraft wakes visible in the stratosphere so that photographs can be taken which yield wake dimensions vs time, and so that aircraft equipped with instruments which measure key exhaust species can find and penetrate the wakes. The object is to provide verification of fluid dynamic and chemical models. Three available models are summarized, and the experimental methods used are described. The Lockheed model predictions correspond in general most closely to experimental wake cross-sectional aerea. NO data are in reasonable agreement with NO predictions, but chemical models are relatively undeveloped, and additional measurements of exhaust products are needed before verification of chemical models becomes possible. However, the overall feasibility of wake visualization for model verification is substantiated. It is emphasized that significant model differences exist that must be resolved before reliable predictions can be made in the wake regimes studied.

Farlow, N. H.↗

The Development and Deployment of a Ground-Based, Laser-Induced Fluorescence Instrument for the In Situ Detection of Iodine Monoxide Radicals

High abundances of iodine monoxide (IO) are known to exist and to participate in local photochemistry of the marine boundary layer. Of particular interest are the roles IO plays in the formation of new particles in coastal marine environments and in depletion episodes of ozone and mercury in the Arctic polar spring. This paper describes a ground-based instrument that measures IO at mixing ratios less than one part in 1012. The IO radical is measured by detecting laser-induced fluorescence at wavelengths longer that 500 nm. Tunable visible light is used to pump the A23/2 (v = 2) ← X23/2 (v = 0) transition of IO near 445 nm. The laser light is produced by a solid-state, Nd:YAG-pumped Ti:Sapphire laser at 5 kHz repetition rate. The laser-induced fluorescence instrument performs reliably with very high signal-to-noise ratios (>10) achieved in short integration times (<1 min). The observations from a validation deployment to the Shoals Marine Lab on Appledore Island, ME are presented and are broadly consistent with in situ observations from European Coastal Sites. Mixing ratios ranged from the instrumental detection limit (<1 pptv) to 10 pptv. These data represent the first in situ point measurements of IO in North America.

marine boundary layer↗

Estimation of total ozone from satellite measurements of backscattered ultraviolet earth radiance.

Total ozone is estimated from Nimbus IV satellite measurements of the attenuation of backscattered radiances at wavelengths between 3100 and 3400 A. A measurement of the backscattered radiance at 3800 A, outside the ozone absorption band, is used to determine an equivalent Lambert albedo for the cloud-ground-haze surface viewed by the instrument. The measured relative attenuation at two wavelengths is compared with such values precomputed for a series of standard ozone profiles and corrected for the equivalent Lambert albedo. Total ozone is obtained by interpolation. Two alternative methods are used to assign an equivalent Lambert albedo at the absorbing wavelengths. Total ozone values estimated by these methods are compared with the Dobson (ground-truth) data by linear regression. The available evidence suggests that the true standard error of the satellite data may be 0.015 atm-cm or less for solar zenith angles smaller than 60 deg.

Mateer, C. L.↗

The Giotto three-dimensional positive ion analyser

An instrument to measure the three-dimensional energy distribution of positive ions in order to study the interaction between the solar wind and ionized Halley cometary particles was designed. Two sensors measure the distribution from 10 eV to 20 keV once per spacecraft spin and the distribution from 90 eV to 90 keV, with coarse mass discrimination, once every 32 spins. The instrument was turned on September 8, 1985. The performance throughout all testing was nominal. The spacecraft was greater than 10 million km from the earth in the solar wind. The only population identified is the solar wind. The Fast Ion Sensor follows solar wind variations with its autoranging capability. The Implanted Ion Sensor identifies higher mass ions such as O(6+) and O(5+) in the solar wind.

Johnstone, A. D.↗

A suggested method for measuring turbulence

The desirability of a quantitative measure of turbulence is emphasized, and a possible method of attack on the problem is discussed. Data are presented to show that the hot-wire anemometer has possibilities as an instrument for measuring turbulence. An apparatus consisting essentially of two hot wire, one parallel to the air flow and one at right angles to it, is suggested.

Taylor, Fayette C↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca2+ and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca2+ content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca2+ content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca2+.

Feeback, Daniel L.↗

Effects of gas–wall partitioning in Teflon tubing and instrumentation on time-resolved measurements of gas-phase organic compounds

Recent studies have demonstrated that organic compounds can partition from the gas phase to the walls in Teflon environmental chambers and that the process can be modeled as absorptive partitioning. Here these studies were extended to investigate gas–wall partitioning of organic compounds in Teflon tubing and inside a proton-transfer-reaction mass spectrometer (PTR-MS) used to monitor compound concentrations. Rapid partitioning of C 8 –C 14 2-ketones and C 11 –C 16 1-alkenes was observed for compounds with saturation concentrations ( c * ) in the range of 3 × 10 4 to 1 × 10 7 µg m -3 , causing delays in instrument response to step-function changes in the concentration of compounds being measured. These delays vary proportionally with tubing length and diameter and inversely with flow rate and c * . The gas–wall partitioning process that occurs in tubing is similar to what occurs in a gas chromatography column, and the measured delay times (analogous to retention times) were accurately described using a linear chromatography model where the walls were treated as an equivalent absorbing mass that is consistent with values determined for Teflon environmental chambers. The effect of PTR-MS surfaces on delay times was also quantified and incorporated into the model. The model predicts delays of an hour or more for semivolatile compounds measured under commonly employed conditions. These results and the model can enable better quantitative design of sampling systems, in particular when fast response is needed, such as for rapid transients, aircraft, or eddy covariance measurements. They may also allow estimation of c * values for unidentified organic compounds detected by mass spectrometry and could be employed to introduce differences in time series of compounds for use with factor analysis methods. Best practices are suggested for sampling organic compounds through Teflon tubing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Disk and circumsolar radiances in the presence of ice clouds

The impact of ice clouds on solar disk and circumsolar radiances is investigated using a Monte Carlo radiative transfer model. The monochromatic direct and diffuse radiances are simulated at angles of 0 to 8° from the center of the sun. Input data for the model are derived from measurements conducted during the 2010 Small Particles in Cirrus (SPARTICUS) campaign together with state-of-the-art databases of optical properties of ice crystals and aerosols. For selected cases, the simulated radiances are compared with ground-based radiance measurements obtained by the Sun and Aureole Measurements (SAM) instrument. First, the sensitivity of the radiances to the ice cloud properties and aerosol optical thickness is addressed. The angular dependence of the disk and circumsolar radiances is found to be most sensitive to assumptions about ice crystal roughness (or, more generally, non-ideal features of ice crystals) and size distribution, with ice crystal habit playing a somewhat smaller role. Second, in comparisons with SAM data, the ice cloud optical thickness is adjusted for each case so that the simulated radiances agree closely (i.e., within 3 %) with the measured disk radiances. Circumsolar radiances at angles larger than ≈ 3° are systematically underestimated when assuming smooth ice crystals, whereas the agreement with the measurements is better when rough ice crystals are assumed. In conclusion, our results suggest that it may well be possible to infer the particle roughness directly from ground-based SAM measurements. In addition, the results show the necessity of correcting the ground-based measurements of direct radiation for the presence of diffuse radiation in the instrument's field of view, in particular in the presence of ice clouds.

54 ENVIRONMENTAL SCIENCES↗

Analysis of the Amplitude Response of a Two-Point and a Two-Line/Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the amplitude response of each instrument to a traveling shock-wave generated by a laser spark. The first FLDI instrument generated two measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated two measurement lines that are oriented either parallel or orthogonal to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along each line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement lines are oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along a single line. When the measurement lines are oriented orthogonal to the shockwave direction of travel, the spatially-varying phase velocity can be obtained by performing a cross-correlation between points at the same relative location on each measurement line. Computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed Schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Focused Laser Differential Interferometer↗