Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Fly-By-Light/Power-By-Wire Fault-Tolerant Fiber-Optic Backplane

The design and development of a fault-tolerant fiber-optic backplane to demonstrate feasibility of such architecture is presented. The simulation results of test cases on the backplane in the advent of induced faults are presented, and the fault recovery capability of the architecture is demonstrated. The architecture was designed, developed, and implemented using the Very High Speed Integrated Circuits (VHSIC) Hardware Description Language (VHDL). The architecture was synthesized and implemented in hardware using Field Programmable Gate Arrays (FPGA) on multiple prototype boards.

Malekpour, Mahyar R.↗

Design and analysis of a Schwarzschild imaging multilayer X-ray microscope

Several Schwarzschild X-ray microscope optics were designed. Diffraction analysis indicates that better than 600 A spatial resolution in the object plane up to a 0.7 mm field of view can be achieved with 100 A radiation. Currently, a 20 x normal incidence multilayer X-ray microscope of 1.35 m overall length is being fabricated. Other microscope systems for use in conjunction with X-ray telescopes were also analyzed and designed. This paper reports on the results of these studies and the X-ray microscope fabrication effort.

Shealy, David L.↗

Design of layered transformation-optics devices of arbitrary shape

Transformation-optics devices of arbitrary shapes usually result in material parameters inside the device that feature level sets of different shapes. Consequently, these devices cannot easily be implemented using a layered architecture and thus are, generally, more difficult to realize in practice. We present a method of designing two-dimensional transformation-optics devices of arbitrary shapes characterized by material parameters of same-level sets, thus suitable to be implemented through concentric layers, each layer being made of a single type of material or metamaterial. Remarkably, we show that transformations leading to such designs are obtained from solutions to the well-known eikonal equation. This approach allows fabrication techniques developed for cylindrical designs of circular cross section to be directly applied to devices of other shapes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NASA Lidar system support and MOPA technology demonstration

A series of lidar design and technology demonstration tasks in support of a CO2 lidar program is discussed. The first of these tasks is discussed in Section VI of this report under the heading of NASA Optical Lidar Design and it consists of detailed recommendations for the layout of a CO2 Doppler lidar incorporating then existing NASA optical components and mounts. The second phase of this work consisted of the design, development, and delivery to NASA of a novel acousto-optic laser frequency stabilization system for use with the existing NASA ring laser transmitter. The second major task in this program encompasses the design and experimental demonstration of a master oscillator-power amplifier (MOPA) laser transmitter utilizing a commercially available laser as the amplifier. The MOPA design including the low chirp master oscillator is discussed in detail. Experimental results are given for one, two and three pass amplification. The report includes operating procedures for the MOPA system.

Laughman, L. M.↗

Design of the ion-optics for the MRSt neutron spectrometer at the National Ignition Facility (NIF)

A new Magnetic Recoil Spectrometer (MRSt) is designed to provide time-resolved measurements of the energy spectrum of neutrons emanating from an inertial confinement fusion implosion at the National Ignition Facility. At present, time integrated parameters are being measured using the existing magnet recoil and neutron time-of-flight spectrometers. The capability of high energy resolution of 2 keV and the extension to high time resolution of about 20 ps are expected to improve our understanding of conditions required for successful fusion experiments. The layout, ion-optics, and specifications of the MRSt will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Stite (IER-148)

The Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimetry intercomparison exercise held at the Nevada National Security Site (NNSS) May 24-27, 2016. The exercise was administered by Lawrence Livermore National Laboratory (LLNL) and consisted of three exposures performed using the Godiva-IV critical assembly housed in the Device Assembly Facility (DAF) located on the NNSS site. The exercise allowed participants to test the ability of their nuclear accident dosimeters to meet the performance criteria in ANSI/HPS N13.3-2013, Dosimetry for Criticality Accidents and to obtain new measurement data for use in revising dose calculation methods and quick sort screening methods where appropriate. PNNL participated with new prototype Personal Nuclear Accident Dosimeter (PNAD) and Fixed Nuclear Accident Dosimeter (FNAD) designs as well as the existing historical PNAD design. The new prototype designs incorporate optically stimulated luminescence (OSL) dosimeters in place of thermoluminescence dosimeters (TLDs), among other design changes, while retaining the same set of activation foils historically used. The default dose calculation methodology established decades ago for use with activation foils in PNNL PNADs and FNADs was used to calculate neutron dose results for both the existing and prototype dosimeters tested in the exercise. The results indicate that the effective cross sections and/or dose conversion factors used historically need to be updated to accurately measure the operational quantities recommended for nuclear accident dosimetry in ANSI/HPS N13.3-2013 and to ensure PNAD and FNAD performance meets the ANSI/HPS N13.3-2013 performance criteria. The operational quantities recommended for nuclear accident dosimetry are personal absorbed dose, Dp(10), and ambient absorbed dose, D*(10).

61 RADIATION PROTECTION AND DOSIMETRY↗

Production of high fluence laser beams using ion wave plasma optics

Optical components for laser beams with high peak and averaged powers are being developed worldwide using stimulated plasma scattering that occurs when plasmas interact with intense, coherent light. After decades of pursuit of pulse compressors, mirrors, and other plasma based components that can be created by stimulated scattering from electron density perturbations forming on ultra-short time scales (e.g., via Stimulated Raman Scattering), more recent work has produced optical components on longer time scales allowing ion motion as well [via Stimulated Brillouin Scattering (SBS)]. In the most recent work, ion wave plasma optics have had success in producing pulses of focusable coherent light with high energy and fluence by operating on ns time scales and now promise to enable numerous applications. Experiments have further shown that in some parameter regimes, even simple plasma response models can describe the output of such optics with sufficient accuracy that they can be used as engineering tools to design plasma optics for future applications, as is already being done to control power deposition in fusion targets. In addition, the development of more sophisticated models promises to enable still higher performance from SBS driven plasma optical components under a wider range of conditions. The present status and most promising directions for future development of ion wave plasma optic techniques are discussed here.

47 OTHER INSTRUMENTATION↗

Polycapillary X-Ray Optics for X-Ray Astronomy

High-energy x-ray spectrometry from astronomical sources is difficult due to low flux rates and high background. Polycapillary x-ray optics can be used to increase the signal-to-noise ratio by focusing photons onto a small energy dispersive detector. Two optics, both designed for x-ray astronomy, have been built and tested as collimating optics with a microfocus x-ray source for x-ray energies up to 70 keV and as focusing optics with parallel x-rays up to 50 keV. Results from these tests show that polycapillary x-ray optics have transmission efficiencies ranging from 5% to 40% and signal gains ranging from 5 to over 100 for energies up to 50 keV. Furthermore the results show that these optics have potential for use up to 100 keV. The experimental results as well as simulations for the measured and for optimized optics will be discussed.

Russell, C. H.↗

Initial Results from NASA’s Low-Cost Optical Terminal (LCOT) at Goddard Space Flight Center

We present the initial results from testing of the Low-Cost Optical Terminal (LCOT) at NASA-Goddard Space Flight Center (GSFC). LCOT is designed to be a single modular design that can be quickly reconfigured to support different laser communication missions. LCOT is built around a 70 cm commercially available telescope designed with optical and quantum communications in mind. We have installed a state-of-the-art adaptive optics system, novel high-power laser amplifiers, and other innovative subsystems developed by our team to facilitate laser communications. We have conducted tests of our LCOT system against operational space terminals, demonstrating our ability to receive a downlink and transmit an uplink. We show the results of these tests and give analysis of the results.

Laser communications↗

Initial Results from NASA’s Low-Cost Optical Terminal (LCOT) at Goddard Space Flight Center

We present the initial results from testing of the Low-Cost Optical Terminal (LCOT) at NASA-Goddard Space Flight Center (GSFC). LCOT is designed to be a single modular design that can be quickly reconfigured to support different laser communication missions. LCOT is built around a 70 cm commercially available telescope designed with optical and quantum communications in mind. We have installed a state-of-the-art adaptive optics system, novel high-power laser amplifiers, and other innovative subsystems developed by our team to facilitate laser communications. We have conducted tests of our LCOT system against operational space terminals, demonstrating our ability to receive a downlink and transmit an uplink. We show the results of these tests and give an analysis of the results.

Ground terminals↗

Photonic Doppler Velocimetry Probe Designed with Stereo Imaging

The velocity distribution of an imploding curved surface is measured with a miniature fiber-optic probe. The probe uses fiber matrix arrays that are focused onto different regions of this curved surface. A pyramid reflector deflects the interrogation onto specific regions of this curved surface. The fiber arrays record velocity along several hundred lines of sight with sub-nanosecond resolution. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called Photonic Doppler velocimetry, providing continuous time records. Within the probe, seven groups of miniature optical relay lenses are grouped into a close-packed array, allowing the interrogation of seven regions of interest. A six-faceted pyramid reflector with a conical hole drilled into its center is used to direct the light beams onto different regions. To minimize back reflections, the fiber matrix arrays are index matched onto the first relay lens made of fused silica. The optical lens design minimizes the laser beam diameters and also provides excellent imaging capabilities. Therefore, two of the fiber matrix arrays are replaced by coherent bundles for stereo imaging recorded by a high-speed framing camera. This requires additional cutouts of the pyramid reflector to allow imaging overlap. Six additional 1.5 mm diameter incoherent bundles are attached to the edges of the pyramid reflector and are used for illumination. Precision metrology on the direction cosines of the trajectories is measured to satisfy environmental requirements for vibration and temperature.

photonic doppler velocimetry, PDV, pyramid reflect↗

D-Egg: a dual PMT optical module for IceCube

The D-Egg, an acronym for "Dual optical sensors in an Ellipsoid Glass for Gen2," is one of the optical modules designed for future extensions of the IceCube experiment at the South Pole. The D-Egg has an elongated-sphere shape to maximize the photon-sensitive effective area while maintaining a narrow diameter to reduce the cost and the time needed for drilling of the deployment holes in the glacial ice for the optical modules at depths up to 2700 m. The D-Egg design is utilized for the IceCube Upgrade, the next stage of the IceCube project also known as IceCube-Gen2 Phase 1, where nearly half of the optical sensors to be deployed are D-Eggs. With two 8-inch high-quantum efficiency photomultiplier tubes (PMTs) per module, D-Eggs offer an increased effective area while retaining the successful design of the IceCube digital optical module (DOM). The convolution of the wavelength-dependent effective area and the Cherenkov emission spectrum provides an effective photodetection sensitivity that is 2.8 times larger than that of IceCube DOMs. The signal of each of the two PMTs is digitized using ultra-low-power 14-bit analog-to-digital converters with a sampling frequency of 240 MSPS, enabling a flexible event triggering, as well as seamless and lossless event recording of single-photon signals to multi-photons exceeding 200 photoelectrons within 10 ns. Mass production of D-Eggs has been completed, with 277 out of the 310 D-Eggs produced to be used in the IceCube Upgrade. In this paper, we report the design of the D-Eggs, as well as the sensitivity and the single to multi-photon detection performance of mass-produced D-Eggs measured in a laboratory using the built-in data acquisition system in each D-Egg optical sensor module.

47 OTHER INSTRUMENTATION↗

RST CGI: Final Verification and Calibration of Prism and Polarizer Flight Units

As part of its technology demonstration, the Nancy Grace Roman Space Telescope Coronagraph Instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The spectroscopy mode is a zero-deviation Amici prism and slit which is deployed to the planet position after an imaging detection. The Wollaston prism polarization optics allow for imaging two orthogonal polarization states simultaneously. The CGI spectral characterization modes, designed and built at Goddard Space Flight Center (GSFC), have a spectral resolution of R50 in two 15% bandpass centered at 660nm and 730nm. There are duplicate Wollaston prism channels, clocked 45 degrees with respect to one another to completely characterize the instrument polarization effects and recover the Stokes parameters of the targeted disk. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. The spectroscopy mode is optimized to target Methane absorption features around 730nm, keeping the spectral resolution as low as possible to improve the signal-to-noise ratio and hence reduce detection time. We highlight the requirements for these modes, the ground-to-orbit calibration process, and the operations required to use a deployable slit on a CGI point source in the presence of pointing error. We also provide further detail on the optomechanical design, testing results from the final as-built flight units, verification process, and performance of the as-built flight assemblies.

high contrast imaging↗

All-optical loadable and erasable memory cell design based on inversionless lasing and electromagnetically induced transparency effects

A loadable and erasable all-optical memory cell is designed by using two coupled micro-ring resonators with electromagnetically induced transparency (EIT) and lasing without inversion (LWI). To read out stored data, an additional phase is introduced in the upper ring resonator due to EIT. To compensate the fibre loss, use is made of LWI. The EIT is induced by inserting {Lambda}-type three level quantum dots in the right-hand half of the upper ring and LWI is implemented by inserted Y-type four level quantum dots in the left-hand half of both rings. This optical memory cell can operate at a low light power level corresponding to several photons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Focusing Light Beams To Improve Atomic-Vapor Optical Buffers

Specially designed focusing of light beams has been proposed as a means of improving the performances of optical buffers based on cells containing hot atomic vapors (e.g., rubidium vapor). There is also a companion proposal to improve performance by use of incoherent optical pumping under suitable conditions. Regarding the proposal to use focusing: The utility of atomic-vapor optical buffers as optical storage and processing devices has been severely limited by nonuniform spatial distributions of intensity in optical beams, arising from absorption of the beams as they propagate in atomic-vapor cells. Such nonuniformity makes it impossible to optimize the physical conditions throughout a cell, thereby making it impossible to optimize the performance of the cell as an optical buffer. In practical terms simplified for the sake of brevity, "to optimize" as used here means to design the cell so as to maximize the group delay of an optical pulse while keeping the absorption and distortion of the pulse reasonably small. Regarding the proposal to use incoherent optical pumping: For reasons too complex to describe here, residual absorption of light is one of the main impediments to achievement of desirably long group delays in hot atomic vapors. The present proposal is directed toward suppressing residual absorption of light. The idea of improving the performance of slow-light optical buffers by use of incoherent pumping overlaps somewhat with the basic idea of Raman-based slow-light systems. However, prior studies of those systems did not quantitatively answer the question of whether the performance of an atomic vapor or other medium that exhibits electromagnetically induced transparency (EIT) with Raman gain is superior to that of a medium that exhibits EIT without Raman gain.

Strekalov, Dmitry↗