Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Improved joint X-ray and neutron refinement procedure in Phenix

Neutron diffraction is one of the three crystallographic techniques (X-ray, neutron and electron diffraction) used to determine the atomic structures of molecules. Its particular strengths derive from the fact that H (and D) atoms are strong neutron scatterers, meaning that their positions, and thus protonation states, can be derived from crystallographic maps. However, because of technical limitations and experimental obstacles, the quality of neutron diffraction data is typically much poorer (completeness, resolution and signal to noise) than that of X-ray diffraction data for the same sample. Further, refinement is more complex as it usually requires additional parameters to describe the H (and D) atoms. The increase in the number of parameters may be mitigated by using the `riding hydrogen' refinement strategy, in which the positions of H atoms without a rotational degree of freedom are inferred from their neighboring heavy atoms. However, this does not address the issues related to poor data quality. Therefore, neutron structure determination often relies on the presence of an X-ray data set for joint X-ray and neutron (XN) refinement. In this approach, the X-ray data serve to compensate for the deficiencies of the neutron diffraction data by refining one model simultaneously against the X-ray and neutron data sets. To be applicable, it is assumed that both data sets are highly isomorphous, and preferably collected from the same crystals and at the same temperature. However, the approach has a number of limitations that are discussed in this work by comparing four separately re-refined neutron models. To address the limitations, a new method for joint XN refinement is introduced that optimizes two different models against the different data sets. This approach is tested using neutron models and data deposited in the Protein Data Bank. The efficacy of refining models with H atoms as riding or as individual atoms is also investigated.

36 MATERIALS SCIENCE↗

Global Ionosphere Perturbations Monitored by the Worldwide GPS Network

For the first time, measurements from the Global Positioning System (GPS) worldwide network are employed to study the global ionospheric total electron content(TEC) changes during a magnetic storm (November 26, 1994). These measurements are obtained from more than 60 world-wide GPS stations which continuously receive dual-frequency signals. Based on the delays of the signals, we have generated high resolution global ionospheric maps (GIM) of TEC at 15 minute intervals. Using a differential method comparing storm time maps with quiet time maps, we find that significant TEC increases (the positive effect ) are the major feature in the winter hemisphere during this storm (the maximum percent change relative to quiet times is about 150 percent).

GPS global positioning system TEC total electron c↗

SPECTROSCOPIC OBSERVATIONS OF AN EVOLVING FLARE RIBBON SUBSTRUCTURE SUGGESTING ORIGIN IN CURRENT SHEET WAVES

We present imaging and spectroscopic observations from the Interface Region Imaging Spectrograph of the evolution of the flare ribbon in the SOL2014-04-18T13:03 M-class flare event, at high spatial resolution and time cadence. These observations reveal small-scale substructure within the ribbon, which manifests as coherent quasi-periodic oscillations in both position and Doppler velocities. We consider various alternative explanations for these oscillations, including modulation of chromospheric evaporation flows. Among these, we find the best support for some form of wave localized to the coronal current sheet, such as a tearing mode or Kelvin–Helmholtz instability.

79 ASTRONOMY AND ASTROPHYSICS↗

Primary track recovery in high-definition gas time projection chambers

Abstract We develop and validate a new algorithm called primary track recovery () that effectively deconvolves known physics and detector effects from nuclear recoil tracks in gas time projection chambers (TPCs) with high-resolution readout. This gives access to the primary track charge, length, and vector direction (helping to resolve the “head-tail” ambiguity). Additionally, provides a measurement of the transverse and longitudinal diffusion widths, which can be used to determine the absolute position of tracks in the drift direction for detector fiducialization. Using simulated helium recoils in an atmospheric pressure TPC with a 70:30 mixture of $$\hbox {He:CO}_2$$ He:CO 2 we compare the performance of to traditional methods for all key track variables. We find that the algorithm reduces reconstruction errors, including those caused by charge integration, for tracks with mean length-to-width ratios 1.4 and above, corresponding to recoil energies of 20 keV and above in the studied TPCs. We show that improves on existing methods for head-tail disambiguation, particularly for highly inclined tracks, and improves the determination of the absolute position of recoils on the drift axis via transverse diffusion. We find that can partially recover charge structure integrated out by the detector in the z direction, but that its determination of energy and length have worse resolution compared to existing methods. We use experimental data to qualitatively verify these findings and discuss implications for future directional detectors at the low-energy frontier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-resolved imaging of current-induced domain-wall oscillations

Current-induced domain-wall dynamics is investigated via high-resolution soft x-ray transmission microscopy by a stroboscopic pump-and-probe measurement scheme at a temporal resolution of 200 ps. A 180{sup o} domain wall in a restoring potential of a permalloy microstructure is displaced from its equilibrium position by nanosecond current pulses leading to oscillations with velocities up to 325 m/s. The motion of the wall is described with an analytical model of a rigid domain wall in a nonharmonic potential allowing one to determine the mass of the domain wall. We show that Oersted fields dominate the domain-wall dynamics in our geometry.

36 MATERIALS SCIENCE↗

Positive parity states in {sup 208}Pb excited by the proton decay of the isobaric analog intruder resonance j{sub 15/2} in {sup 209}Bi

With the Q3D magnetic spectrograph of the Maier-Leibnitz-Laboratorium at Muenchen at a resolution of about 3 keV, angular distributions and excitation functions of the reaction {sup 208}Pb(p,p{sup '}) were measured at some scattering angles 20 deg. - 138 deg. for several proton energies 14.8-18.1 MeV. All seven known isobaric analog resonances in {sup 209}Bi are covered. By the excitation near the j{sub 15/2} intruder resonance in {sup 209}Bi, several new positive parity states in {sup 208}Pb with excitation energies 4.6-6.2 MeV are identified by comparison of the mean cross section to the known single particle widths. The dominant configuration for 27 positive parity states is determined and compared to the schematic shell model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary neutron crystallographic analysis of selectively CH 3 -protonated deuterated rubredoxin from Pyrococcus furiosus

Neutron crystallography is used to locate hydrogen atoms in biological materials and can distinguish between negatively scattering hydrogen and positively scattering deuterium substituted positions in isomorphous neutron structures. Recently, Hauptman and Langs (2003) have shown that neutron diffraction data can be used to solve macromolecular structures by direct methods and that solution is aided by the presence of negatively scattering hydrogen atoms in the structure. Selective labeling protocols allow the design and production of H/D-labeled macromolecular structures in which the ratio of hydrogen to deuterium atoms can be precisely controlled. We have applied methyl-selective labeling protocols to introduce (1H-delta methyl)-leucine and (1H-gamma methyl)-valine into deuterated rubredoxin from Pyrococcus furiosus (PfRd). Here we report on the production, crystallization, and preliminary neutron analysis of the selectively CH 3 -protonated, deuterated PfRd sample, which provided a high quality neutron data set extending to 1.75 Å resolution at the new LADI-III instrument at the Insititut Laue-Langevin. Preliminary analysis of neutron density maps allows unambiguous assignment of the positions of hydrogen atoms at the methyl groups of the valine and leucine residues in the otherwise deuterated rubredoxin structure.

08 HYDROGEN↗

Neutron and high-resolution room-temperature X-ray data collection from crystallized lytic polysaccharide monooxygenase

Bacteria and fungi express lytic polysaccharide monooxgyenase (LPMO) enzymes that act in conjunction with canonical hydrolytic sugar-processing enzymes to rapidly convert polysaccharides such as chitin, cellulose and starch to single monosaccharide products. In order to gain a better understanding of the structure and oxidative mechanism of these enzymes, large crystals (1–3 mm 3 ) of a chitin-processing LPMO from the Gram-positive soil bacterium Jonesia denitrificans were grown and screened for their ability to diffract neutrons. In addition to the collection of neutron diffraction data, which were processed to 2.1 Å resolution, a high-resolution room-temperature X-ray diffraction data set was collected and processed to 1.1 Å resolution in space group P 2 1 2 1 2 1 . To our knowledge, this work marks the first successful neutron crystallographic experiment on an LPMO. As a result, joint X-ray/neutron refinement of the resulting data will reveal new details of the structure and mechanism of this recently discovered class of enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source

The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.

36 MATERIALS SCIENCE↗

Surface temperature comparison of the Arctic winter MOSAiC observations, ERA5 reanalysis, and MODIS satellite retrieval

Atmospheric model systems, such as those used for weather forecast and reanalysis production, often have significant and systematic errors in their representation of the Arctic surface energy budget and its components. The newly available observation data of the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition (2019/2020) enable a range of model analyses and validation in order to advance our understanding of potential model deficiencies. In the present study, we analyze deficiencies in the surface radiative energy budget over Arctic sea ice in the ERA5 global atmospheric reanalysis by comparing against the winter MOSAiC campaign data, as well as, a pan-Arctic level-2 MODIS ice surface temperature remote sensing product. We find that ERA5 can simulate the timing of radiatively clear periods, though it is not able to distinguish the two observed radiative Arctic winter states, radiatively clear and opaquely cloudy, in the distribution of the net surface radiative budget. The ERA5 surface temperature over Arctic sea ice has a conditional error with a positive bias in radiatively clear conditions and a negative bias in opaquely cloudy conditions. The mean surface temperature error is 4°C for radiatively clear situations at MOSAiC and up to 15°C in some parts of the Arctic. The spatial variability of the surface temperature, given by 4 observation sites at MOSAiC, is not captured by ERA5 due to its spatial resolution but represented in the level-2 satellite product. The sensitivity analysis of possible error sources, using satellite products of snow depth and sea ice thickness, shows that the positive surface temperature errors during radiatively clear events are, to a large extent, caused by insufficient sea ice thickness and snow depth representation in the reanalysis system. A positive bias characterizes regions with ice thickness greater than 1.5 m, while the negative bias for thinner ice is partly compensated by the effect of snow.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric {sup 41}Ar Plume Tracking of the UF Training Reactor Using a Large-Volume NaI Detector

The ability to track and monitor gaseous radioactive materials is important in the event of a radioactive release such as from a nuclear power plant accident, weapons testing, or other unintended release scenarios. The International Monitoring System (IMS) is currently in place to monitor for weapons testing and has been used to monitor nuclear power plant accidents. However, only 80 radionuclide stations for the IMS exist in the world and are stationary, limiting the resolution of any radioactive plumes detected. Furthermore, the IMS radionuclide stations are designed to be sensitive specifically to atmospheric radio-xenon and no other radionuclides. Historically, monitoring radioactive releases has been limited to the detection of radio-xenon and radio-krypton, both arising as fission products from nuclear fuel. After the accident at Three Mile Island Unit 2, scientists were interested in finding the dose the public received from released radioactive material. This was achieved by analyzing radiation monitors in the exhaust stack and filters within the reactor building. furthermore, a series of 20 thermoluminescent dosimeters (TLD's), 8 air sampling station positioned around Three Mile Island, and a helicopter survey which used a NaI(Tl) detector array provided data on radionuclides, specifically {sup 137}Cs, that escaped the confines of the reactor building. The TLD's and air sampling stations were stationary, and therefore limited the resolution of the radioactive release plume. The helicopter survey using the NaI detectors was limited by the technology available at the time. The NaI detector array output was compressed from 1024 channels to 256 channels, limiting the energy resolution of the spectral data. The helicopter used a microwave ranging system to establish position. Since this survey was taken in October of 1982, advancements in technology allow spectral data to be saved in its full 1024 channel format and the advent of GPS can give a more accurate account of the detector position. An updated mobile system for tracking a radioactive release would help to alleviate these issues as well as gain the ability to track a radioactive release in real-time. We investigate the feasibility of mobile tracking through study and measurement of the {sup 41}Ar plume released from the University of Florida Training Reactor (UFTR) research reactor. We use a large-volume NaI(Tl) detector placed on the roof near the reactor. This detector may also be placed and moved on a cart to survey the area surrounding the reactor. We compare the spectral data taken when the reactor is running at full power to the background to analyze the effectiveness of the detector at identifying atmospheric {sup 41}Ar. Finally we discuss the implications of these measurements with regards to validation of plume models and the capability to track releases over a localized area from the source. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Structural and Functional Analysis of the Interaction Between the Nucleoporin Nup214 and the DEAD-box Helicase Ddx19

Key steps in the export of mRNA from the nucleus to the cytoplasm are the transport through the nuclear pore complex (NPC) and the subsequent remodeling of messenger RNA-protein (mRNP) complexes that occurs at the cytoplasmic side of the NPC. Crucial for these events is the recruitment of the DEAD-box helicase Ddx19 to the cytoplasmic filaments of the NPC that is mediated by the nucleoporin Nup214. Here, we present the crystal structure of the Nup214 N-terminal domain in complex with Ddx19 in its ADP-bound state at 2.5 {angstrom} resolution. Strikingly, the interaction surfaces are not only evolutionarily conserved but also exhibit strongly opposing surface potentials, with the helicase surface being positively and the Nup214 surface being negatively charged. We speculate that the positively charged surface of the interacting ADP-helicase binds competitively to a segment of mRNA of a linearized mRNP, passing through the NPC on its way to the cytoplasm. As a result, the ADP-helicase would dissociate from Nup214 and replace a single bound protein from the mRNA. One cycle of protein replacement would be accompanied, cooperatively, by nucleotide exchange, ATP hydrolysis, release of the ADP-helicase from mRNA and its rebinding to Nup214. Repeat of these cycles would remove proteins from a mRNP, one at a time, akin to a ratchet mechanism for mRNA export.

59 BASIC BIOLOGICAL SCIENCES↗

R and DE Robotic Sensor Intern Team: Remote 3D Mapping Overview

The Department of Energy (DOE) nuclear complex includes many hazardous and challenging environments that must be inspected remotely and routinely for structural integrity evaluation and long-term planning purposes. The H-Canyon Air Exhaust (HCAEX) Tunnel biannual inspection is an example of such an environment. Presently inspections are performed by teleoperated robotic crawlers provide low resolution video feedback to the structural engineers. Advanced sensors such as Lidar and panospheric hi-res cameras have the potential to provide additional valuable data in future inspections. UT-Austin Lidar work in support of an H-Canyon deployment began with the DOE EM sponsored H-Canyon Integrated Research Project. The R and DE Robotic Sensor intern team includes two of the UT-Austin Masters students working on Lidar development to facilitate the pulling of university developed solutions to the field. The goal of this project is to develop a suite of sensors that could be used to gather advanced data in future HCAEX tunnel inspections. Of particular interest is the ability to map the tunnel walls at an accuracy that will allow for the comparison of two scans performed at different time periods to estimate the concrete erosion rate. Additionally, the development of the 3D point cloud in the GPS denied environment is the first step in being able to collect and overlay other 3D data such as radiation mapping. Project specific goals include: - Design and develop 3D mapping sensor suite. Merge Lidar point cloud with high res camera images Incorporate Inertial Measurement Unit (IMU) to assist with positioning. - Develop sensor software and user GUI Sensor data collection and integration software User GUI for reach back system. - Test solution on crawler in tunnel test bed Use crawler base similar to H-Canyon planned crawler Design and build test bed simulating tunnel conditions. To facilitate rapid sensor integration, software coding and user GUI development, the Robot Operating System (ROS) was employed as the development platform. ROS is a set of open source software libraries and tools that assist with the building of robot applications. ROS includes drivers for many sensors, state-of-the-art algorithms, and powerful developer tools. Sensors selected for the summer intern solution included assessment as to whether they possessed ROS drivers and associated sample code. Additionally, the ROS 3D Robot Visualizer (rviz) tool has been employed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SS 383: A NEW S-TYPE YELLOW SYMBIOTIC STAR?

Symbiotic stars are key objects in understanding the formation and evolution of interacting binary systems, and are probably the progenitors of Type Ia supernovae. However, the number of known symbiotic stars is much lower than predicted. We aim to search for new symbiotic stars, with particular emphasis on the S-type yellow symbiotic stars, in order to determine their total population, evolutionary timescales, and physical properties. The Two Micron All Sky Survey (2MASS) (J – H) versus (H – K {sub s}) color-color diagram has been previously used to identify new symbiotic star candidates and show that yellow symbiotics are located in a particular region of that diagram. Candidate symbiotic stars are selected on the basis of their locus in the 2MASS (J – H) versus (H – K {sub s}) diagram and the presence of Hα line emission in the Stephenson and Sanduleak Hα survey. This diagram separates S-type yellow symbiotic stars from the rest of the S-type symbiotic stars, allowing us to select candidate yellow symbiotics. To establish the true nature of the candidates, intermediate-resolution spectroscopy is obtained. We have identified the Hα emission line source SS 383 as an S-type yellow symbiotic candidate by its position in the 2MASS color-color diagram. The optical spectrum of SS 383 shows Balmer, He I, He II, and [O III] emission lines, in combination with TiO absorption bands that confirm its symbiotic nature. The derived electron density (≅10{sup 8-9} cm{sup –3}), He I emission line intensity ratios, and position in the [O III] λ5007/Hβ versus [O III] λ4363/Hγ diagram indicate that SS 383 is an S-type symbiotic star, with a probable spectral type of K7-M0 deduced for its cool component based on TiO indices. The spectral type and the position of SS 383 (corrected for reddening) in the 2MASS color-color diagram strongly suggest that SS 383 is an S-type yellow symbiotic. Our result points out that the 2MASS color-color diagram is a powerful tool in identifying new S-type yellow symbiotics.

79 ASTRONOMY AND ASTROPHYSICS↗

X-Rays Compton Detectors For Biomedical Application

Collimators are usually needed to image sources emitting X-rays that cannot be focused. Alternately, one may employ a Compton Camera (CC) and measure the direction of the incident X-ray by letting it interact with a thin solid, liquid or gaseous material (Tracker) and determine the scattering angle. With respect to collimated cameras, CCs allow higher gamma-ray efficiency in spite of lighter geometry, and may feature comparable spatial resolution. CCs are better when the X-ray energy is high and small setups are required. We review current applications of CCs to Gamma Ray Astronomy and Biomedical systems stressing advantages and drawbacks. As an example, we focus on a particular CC we are developing, which is designed to image small animals administered with marked pharmaceuticals, and assess the bio-distribution and targeting capability of these latter. This camera has to address some requirements: relatively high activity of the imaged objects; detection of gamma-rays of different energies that may range from 140 keV (Tc99m) to 511 keV; presence of gamma and beta radiation with energies up to 2 MeV in case of 188Re. The camera consists of a thin position-sensitive Silicon Drift Detector as Tracker, and a further downstream position-sensitive system employing scintillating crystals and a multi-anode photo-multiplier (Calorimeter). The choice of crystal, pixel size, and detector geometry has been driven by measurements and simulations with the tracking code GEANT4. Spatial resolution, efficiency and scope are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the ROSAT HRI Spectral Response

The ROSAT High Resolution Imager has a limited (2-band) spectral response. This spectral capability can give X-ray hardness ratios on spatial scales of 5 arcseconds. The spectral response of the center of the detector was calibrated before the launch of ROSAT, but the gain decreases with time and also is a function of position on the detector. To complicate matters further, the satellite is 'wobbled', possibly moving a source across several spatial gain states. These difficulties have prevented the spectral response of the ROSAT High Resolution Imager (HRI) from being used for scientific measurements. We have used Bright Earth data and in-flight calibration sources to map the spatial and temporal gain changes, and written software which will allow ROSAT users to generate a calibrated XSPEC (an x ray spectral fitting package) response matrix and hence determine a calibrated hardness ratio. In this report, we describe the calibration procedure and show how to obtain a response matrix. In Section 2 we give an overview of the calibration procedure, in Section 3 we give a summary of HRI spatial and temporal gain variations. Section 4 describes the routines used to determine the gain distribution of a source. In Sections 5 and 6, we describe in detail how, the Bright Earth database and calibration sources are used to derive a corrected response matrix for a given observation. Finally, Section 7 describes how to use the software.

Prestwich, Andrea H.↗

Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT

Purpose: Cardiac CT achieves its high temporal resolution by lowering the scan range from 2{pi} to {pi} plus fan angle (partial scan). This, however, introduces CT-value variations, depending on the angular position of the {pi} range. These partial scan artifacts are of the order of a few HU and prevent the quantitative evaluation of perfusion measurements. The authors present the new algorithm partial scan artifact reduction (PSAR) that corrects a dynamic phase-correlated scan without a priori information. Methods: In general, a full scan does not suffer from partial scan artifacts since all projections in [0, 2{pi}] contribute to the data. To maintain the optimum temporal resolution and the phase correlation, PSAR creates an artificial full scan p{sub n}{sup AF} by projectionwise averaging a set of neighboring partial scans p{sub n}{sup P} from the same perfusion examination (typically N{approx_equal}30 phase-correlated partial scans distributed over 20 s and n=1,...,N). Corresponding to the angular range of each partial scan, the authors extract virtual partial scans p{sub n}{sup V} from the artificial full scan p{sub n}{sup AF}. A standard reconstruction yields the corresponding images f{sub n}{sup P}, f{sub n}{sup AF}, and f{sub n}{sup V}. Subtracting the virtual partial scan image f{sub n}{sup V} from the artificial full scan image f{sub n}{sup AF} yields an artifact image that can be used to correct the original partial scan image: f{sub n}{sup C}=f{sub n}{sup P}-f{sub n}{sup V}+f{sub n}{sup AF}, where f{sub n}{sup C} is the corrected image. Results: The authors evaluated the effects of scattered radiation on the partial scan artifacts using simulated and measured water phantoms and found a strong correlation. The PSAR algorithm has been validated with a simulated semianthropomorphic heart phantom and with measurements of a dynamic biological perfusion phantom. For the stationary phantoms, real full scans have been performed to provide theoretical reference values. The improvement in the root mean square errors between the full and the partial scans with respect to the errors between the full and the corrected scans is up to 54% for the simulations and 90% for the measurements. Conclusions: The phase-correlated data now appear accurate enough for a quantitative analysis of cardiac perfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystal structure of a fully glycosylated HIV-1 gp120 core reveals a stabilizing role for the glycan at Asn262

The crystal structure of a fully glycosylated HIV-1 gp120 core in complex with CD4 receptor and Fab 17b at 4.5-Å resolution reveals 9 of the 15 N-linked glycans of core gp120 to be partially ordered. The glycan at position Asn262 had the most extensive and well-ordered electron density, and a GlcNAc 2 Man 7 was modeled. Lastly, the GlcNAc stem of this glycan is largely buried in a cleft in gp120, suggesting a role in gp120 folding and stability. Its arms interact with the stems of neighboring glycans from the oligomannose patch, which is a major target for broadly neutralizing antibodies.

60 APPLIED LIFE SCIENCES↗