Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Overview of Hazard Assessment and Emergency Planning Software of Use to RN First Responders

There are numerous software tools available for field deployment, reach-back, training and planning use in the event of a radiological or nuclear (RN) terrorist event. Specialized software tools used by CBRNe responders can increase information available and the speed and accuracy of the response, thereby ensuring that radiation doses to responders, receivers, and the general public are kept as low as reasonably achievable. Software designed to provide health care providers with assistance in selecting appropriate countermeasures or therapeutic interventions in a timely fashion can improve the potential for positive patient outcome. This paper reviews various software applications of relevance to radiological and nuclear (RN) events that are currently in use by first responders, emergency planners, medical receivers, and criminal investigators.

54 ENVIRONMENTAL SCIENCES↗

Usefulness of Diffusion-Weighted Imaging in the Localization of Prostate Cancer

Purpose: Advances in high-precision radiation therapy techniques for patients with prostate cancer permit selective escalation of the radiation dose delivered to the dominant intraprostatic lesion and improve the therapeutic ratio. We evaluated the value of diffusion-weighted imaging (DWI) for dominant intraprostatic lesion assessment. Methods and Materials: The study population consisted of 23 patients with early prostate cancer. Before undergoing total prostatectomy, they were evaluated by means of magnetic resonance imaging, including DWI. T2-weighted imaging (T2WI) with and without DWI were retrospectively assessed by six independent observers. Imaging findings were compared with pathologic results from whole prostate specimens on a lesion-by-lesion basis. Results: Pathologic study identified 43 lesions in 23 patients. On magnetic resonance imaging, the six observers correctly identified 11-22 of 43 lesions (sensitivity, 26-51%) on T2WI alone and 20-31 (sensitivity, 47-72%) on T2WI plus DWI. Positive predictive values were 42-73% on T2WI alone and 58-80% on T2WI plus DWI. For all observers, detection was higher on combined T2WI and DWI than on T2WI alone. Conclusion: Because the addition of DWI to T2WI improves the detectability of prostate cancer, DWI may offer a promising new approach for radiation therapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A 3D global-to-local deformable mesh model based registration and anatomy-constrained segmentation method for image guided prostate radiotherapy

Purpose: In the external beam radiation treatment of prostate cancers, successful implementation of adaptive radiotherapy and conformal radiation dose delivery is highly dependent on precise and expeditious segmentation and registration of the prostate volume between the simulation and the treatment images. The purpose of this study is to develop a novel, fast, and accurate segmentation and registration method to increase the computational efficiency to meet the restricted clinical treatment time requirement in image guided radiotherapy. Methods: The method developed in this study used soft tissues to capture the transformation between the 3D planning CT (pCT) images and 3D cone-beam CT (CBCT) treatment images. The method incorporated a global-to-local deformable mesh model based registration framework as well as an automatic anatomy-constrained robust active shape model (ACRASM) based segmentation algorithm in the 3D CBCT images. The global registration was based on the mutual information method, and the local registration was to minimize the Euclidian distance of the corresponding nodal points from the global transformation of deformable mesh models, which implicitly used the information of the segmented target volume. The method was applied on six data sets of prostate cancer patients. Target volumes delineated by the same radiation oncologist on the pCT and CBCT were chosen as the benchmarks and were compared to the segmented and registered results. The distance-based and the volume-based estimators were used to quantitatively evaluate the results of segmentation and registration. Results: The ACRASM segmentation algorithm was compared to the original active shape model (ASM) algorithm by evaluating the values of the distance-based estimators. With respect to the corresponding benchmarks, the mean distance ranged from -0.85 to 0.84 mm for ACRASM and from -1.44 to 1.17 mm for ASM. The mean absolute distance ranged from 1.77 to 3.07 mm for ACRASM and from 2.45 to 6.54 mm for ASM. The volume overlap ratio ranged from 79% to 91% for ACRASM and from 44% to 80% for ASM. These data demonstrated that the segmentation results of ACRASM were in better agreement with the corresponding benchmarks than those of ASM. The developed registration algorithm was quantitatively evaluated by comparing the registered target volumes from the pCT to the benchmarks on the CBCT. The mean distance and the root mean square error ranged from 0.38 to 2.2 mm and from 0.45 to 2.36 mm, respectively, between the CBCT images and the registered pCT. The mean overlap ratio of the prostate volumes ranged from 85.2% to 95% after registration. The average time of the ACRASM-based segmentation was under 1 min. The average time of the global transformation was from 2 to 4 min on two 3D volumes and the average time of the local transformation was from 20 to 34 s on two deformable superquadrics mesh models. Conclusions: A novel and fast segmentation and deformable registration method was developed to capture the transformation between the planning and treatment images for external beam radiotherapy of prostate cancers. This method increases the computational efficiency and may provide foundation to achieve real time adaptive radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dedicated breast computed tomography: Basic aspects

X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed.

60 APPLIED LIFE SCIENCES↗

The radiation chemistry of Cs-7SB, a solvent modifier used in Cs and Sr extraction

The solvent modifier 1-(2,2,3,3-tetrafluoro-propoxy)-3-(4-sec-butylphenoxy)-2-propanol, (Cs- 7SB) is used in conjunction with calixarenes and crown ethers dissolved in alkane diluents for the extraction of Cs and Sr from highly radioactive solutions. Its purpose is to solvate the ligands and the resulting ligand-metal complexes in the organic phase. Given this role, and its relatively high concentration in the formulations used for solvent extraction, radiolytic degradation of Cs-7SB might decrease the extraction efficiency of these elements as the solvent accumulates absorbed radiation dose. This work presents the results of studies of Cs-7SB using post-radiolysis gas chromatography with electron-capture detection and solvent-extraction distribution-ratio measurements. Also presented is the kinetic analysis of the bimolecular rate constant for the modifier's reaction with nitrogen trioxide and nitrogen dioxide radicals, major radiolytically-produced radical species in irradiated aqueous nitric acid. Although Cs-7SB was found to undergo reactions with nitrogen-centered radicals, little decrease in extraction efficiency was found. It is concluded the modifier, always present at concentrations much higher than the ligands, acts as a radical scavenger, protecting ligands from radiolytic attack. (authors)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dermatofibrosarcoma Protuberans: Long-term Outcomes of 53 Patients Treated With Conservative Surgery and Radiation Therapy

Purpose: To evaluate outcomes of conservative surgery and radiation therapy (RT) treatment in patients with dermatofibrosarcoma protuberans. Methods and Materials: We retrospectively reviewed the medical records of 53 consecutive dermatofibrosarcoma protuberans patients treated with surgery and preoperative or postoperative radiation therapy between 1972 and 2010. Median tumor size was 4 cm (range, 1-25 cm). Seven patients (13%) were treated with preoperative RT (50-50.4 Gy) and 46 patients (87%) with postoperative RT (60-66 Gy). Of the 46 patients receiving postoperative radiation, 3 (7%) had gross disease, 14 (30%) positive margins, 26 (57%) negative margins, and 3 (7%) uncertain margin status. Radiation dose ranged from 50 to 66 Gy (median dose, 60 Gy). Results: At a median follow-up time of 6.5 years (range, 0.5 months-23.5 years), 2 patients (4%) had disease recurrence, and 3 patients (6%) had died. Actuarial overall survival was 98% at both 5 and 10 years. Local control was 98% and 93% at 5 and 10 years, respectively. Disease-free survival was 98% and 93% at 5 and 10 years, respectively. The presence of fibrosarcomatous change was not associated with increased risk of local or distant relapse (P=.43). One of the patients with a local recurrence had gross residual disease at the time of RT and despite RT to 65 Gy developed both an in-field recurrence and a nodal and distant recurrence 3 months after RT. The other patient with local recurrence was found to have in-field recurrence 10 years after initial treatment. Thirteen percent of patients had an RT complication at 5 and 10 years, and 9% had a moderate or severe complication at 5 and 10 years. Conclusions: Dermatofibrosarcoma protuberans is a radioresponsive disease with excellent local control after conservative surgery and radiation therapy. Adjuvant RT should be considered for patients with large or recurrent tumors or when attempts at wide surgical margins would result in significant morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-C-BRB-02: ASTRO President [ Diagnostic radiology and radiation oncology ]

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗

MO-C-BRB-03: RSNA President [ Diagnostic radiology and radiation oncology ]

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗

Risk of First and Recurrent Stroke in Childhood Cancer Survivors Treated With Cranial and Cervical Radiation Therapy

Purpose: To assess, in a retrospective cohort study, rates and predictors of first and recurrent stroke in patients treated with cranial irradiation (CRT) and/or cervical irradiation at ≤18 years of age. Methods and Materials: We performed chart abstraction (n=383) and phone interviews (n=104) to measure first and recurrent stroke in 383 patients who received CRT and/or cervical radiation at a single institution between 1980 and 2009. Stroke was defined as a physician diagnosis and symptoms consistent with stroke. Incidence of first stroke was number of first strokes per person-years of observation after radiation. We used survival analysis techniques to determine cumulative incidence of first and recurrent stroke. Results: Among 325 subjects with sufficient follow-up data, we identified 19 first strokes (13 ischemic, 4 hemorrhagic, 2 unknown subtype) occurring at a median age of 24 years (interquartile range 17-33 years) in patients treated with CRT. Imaging was reviewed when available (n=13), and the stroke was confirmed in 12. Overall rate of first stroke was 625 (95% confidence interval [CI] 378-977) per 100,000 person-years. The cumulative incidence of first stroke was 2% (95% CI 0.01%-5.3%) at 5 years and 4% (95% CI 2.0%-8.4%) at 10 years after irradiation. With each 100-cGy increase in the radiation dose, the stroke hazard increased by 5% (hazard ratio 1.05; 95% CI 1.01-1.09; P=.02). We identified 6 recurrent strokes; 5 had available imaging that confirmed the stroke. Median time to recurrence was 15 months (interquartile range 6 months-3.2 years) after first stroke. The cumulative incidence of recurrent stroke was 38% (95% CI 17%-69%) at 5 years and 59% (95% CI 27%-92%) at 10 years after first stroke. Conclusion: Cranial irradiation puts childhood cancer survivors at high risk of both first and recurrent stroke. Stroke prevention strategies for these survivors are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-268: Change of CT Number During the Course of Chemoradiation Therapy for Pancreatic Cancer

Purpose: It has been observed radiation can induce changes in CT number (CTN) inside tumor during the course of radiation therapy (RT) for several tumor sites including lung and head and neck, suggesting that the CTN change may be potentially used to assess RT response. In this study, we investigate the CTN changes inside tumor during the course of chemoradiation therapy (CRT) for pancreatic cancer. Methods: Daily diagnostic-quality CT data acquired during IGRT for 17 pancreatic head cancer patients using an in-room CT (CTVision, Siemens) were analyzed. All patients were treated with a radiation dose of 50.4 in 1.8 Gy per fraction. On each daily CT set, The contour of the pancreatic head, included in the treatment target, was generated by populating the pancreatic head contour from the planning CT or MRI using an auto-segmentation tool based on deformable registration (ABAS, Elekta) with manual editing if necessary. The CTN at each voxel in the pancreatic head contour was extracted and the 3D distribution of the CTNs was processed using MATLAB. The mean value of CTN distribution was used to quantify the daily CTN change in the pancreatic head. Results: Reduction of CTN in pancreatic head was observed during the CRT delivery in 14 out the 17 (82%) patients studied. Although the average reduction is only 3.5 Houncefield Unit (HU), this change is significant (p<0.01). Among them, there are 7 patients who had a CTN drop larger than 5 HU, ranging from 6.0 to 11.8 HU. In contrast to this trend, CTN was increased in 3 patients. Conclusion: Measurable changes in the CT number in tumor target were observed during the course of chemoradiation therapy for the pancreas cancer patients, indicating this radiation-induced CTN change may be used to assess treatment response.

60 APPLIED LIFE SCIENCES↗

TU-F-17A-06: Motion Stability and Dosimetric Impact of Spirometer-Based DIBH-RT of Left-Sided Breast Cancer

Purpose: Patients undergoing radiotherapy (RT) for left-sided breast cancer have increased risk of coronary artery disease. Deep Inhalation Breath Hold assisted RT (DIBH-RT) is shown to increase the geometric separation of the target area and heart, reducing cardiac radiation dose. The purposes of this study are to use Cine MV portal images to determine the stability of spirometer-guided DIBH-RT and examine the dosimetric cardiopulmonary impact of this technique. Methods: Twenty consecutive patients with left-sided breast cancer were recruited to the IRB-approved study. Free-breathing (FB) and DIBH-CT's were acquired at simulation. Rigid registration of the FB-CT and DIBH-CT was performed using primarily breast tissue. Treatment plans were created for each FB-CT and DIBH-CT using identical paired tangent fields with field-in-field or electronic compensation techniques. Dosimetric evaluation included mean and maximum (Dmax) doses for the left anterior descending artery (LAD), mean heart dose, and left lung V20. Cine MV portal images were acquired for medial and lateral fields during treatment. Analysis of Cine images involved chest wall segmentation using an algorithm developed in-house. Intra- and inter-fractional chest wall motion were determined through affine registration to the first frame of each Cine. Results: Dose to each cardiac structure evaluated was significantly (p<0.001) reduced with the DIBH plans. Mean heart dose decreased from 2.9(0.9–6.6) to 1.6(0.6–5.3) Gy; mean LAD dose from 16.6(3–43.6) to 7.4(1.7–32.7) Gy; and LAD Dmax from 35.4 (6.1–53) to 18.4(2.5–51.2) Gy. No statistically significant reduction was found for the left lung V20. Average AP and SI median chest wall motion (intrafractional) was 0.1 (SD=0.9) and 0.5 (SD=1.1) mm, respectively. Average AP inter-fractional chest wall motion was 2.0 (SD=1.4) mm. Conclusion: Spirometer-based DIBH treatments of the left breast are reproducible both inter- and intra-fractionally, and provide a statistically and potentially clinically useful dosimetric advantage to cardiac structures.

60 APPLIED LIFE SCIENCES↗

A Validated Prediction Model for Overall Survival From Stage III Non-Small Cell Lung Cancer: Toward Survival Prediction for Individual Patients

Purpose: Although patients with stage III non-small cell lung cancer (NSCLC) are homogeneous according to the TNM staging system, they form a heterogeneous group, which is reflected in the survival outcome. The increasing amount of information for an individual patient and the growing number of treatment options facilitate personalized treatment, but they also complicate treatment decision making. Decision support systems (DSS), which provide individualized prognostic information, can overcome this but are currently lacking. A DSS for stage III NSCLC requires the development and integration of multiple models. The current study takes the first step in this process by developing and validating a model that can provide physicians with a survival probability for an individual NSCLC patient. Methods and Materials: Data from 548 patients with stage III NSCLC were available to enable the development of a prediction model, using stratified Cox regression. Variables were selected by using a bootstrap procedure. Performance of the model was expressed as the c statistic, assessed internally and on 2 external data sets (n=174 and n=130). Results: The final multivariate model, stratified for treatment, consisted of age, gender, World Health Organization performance status, overall treatment time, equivalent radiation dose, number of positive lymph node stations, and gross tumor volume. The bootstrapped c statistic was 0.62. The model could identify risk groups in external data sets. Nomograms were constructed to predict an individual patient's survival probability ( (www.predictcancer.org)). The data set can be downloaded at (https://www.cancerdata.org/10.1016/j.ijrobp.2015.02.048). Conclusions: The prediction model for overall survival of patients with stage III NSCLC highlights the importance of combining patient, clinical, and treatment variables. Nomograms were developed and validated. This tool could be used as a first building block for a decision support system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon-Ion Pencil Beam Scanning Treatment With Gated Markerless Tumor Tracking: An Analysis of Positional Accuracy

Purpose: Having implemented amplitude-based respiratory gating for scanned carbon-ion beam therapy, we sought to evaluate its effect on positional accuracy and throughput. Methods and Materials: A total of 10 patients with tumors of the lung and liver participated in the first clinical trials at our center. Treatment planning was conducted with 4-dimensional computed tomography (4DCT) under free-breathing conditions. The planning target volume (PTV) was calculated by adding a 2- to 3-mm setup margin outside the clinical target volume (CTV) within the gating window. The treatment beam was on when the CTV was within the PTV. Tumor position was detected in real time with a markerless tumor tracking system using paired x-ray fluoroscopic imaging units. Results: The patient setup error (mean ± SD) was 1.1 ± 1.2 mm/0.6 ± 0.4°. The mean internal gating accuracy (95% confidence interval [CI]) was 0.5 mm. If external gating had been applied to this treatment, the mean gating accuracy (95% CI) would have been 4.1 mm. The fluoroscopic radiation doses (mean ± SD) were 23.7 ± 21.8 mGy per beam and less than 487.5 mGy total throughout the treatment course. The setup, preparation, and irradiation times (mean ± SD) were 8.9 ± 8.2 min, 9.5 ± 4.6 min, and 4.0 ± 2.4 min, respectively. The treatment room occupation time was 36.7 ± 67.5 min. Conclusions: Internal gating had a much higher accuracy than external gating. By the addition of a setup margin of 2 to 3 mm, internal gating positional error was less than 2.2 mm at 95% CI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mesenchymal Stem Cells Retain Their Defining Stem Cell Characteristics After Exposure to Ionizing Radiation

Purpose: Mesenchymal stem cells (MSCs) have the ability to migrate to lesion sites and undergo differentiation into functional tissues. Although this function may be important for tissue regeneration after radiation therapy, the influence of ionizing radiation (IR) on cellular survival and the functional aspects of differentiation and stem cell characteristics of MSCs have remained largely unknown. Methods and Materials: Radiation sensitivity of human primary MSCs from healthy volunteers and primary human fibroblast cells was examined, and cellular morphology, cell cycle effects, apoptosis, and differentiation potential after exposure to IR were assessed. Stem cell gene expression patterns after exposure to IR were studied using gene arrays. Results: MSCs were not more radiosensitive than human primary fibroblasts, whereas there were considerable differences regarding radiation sensitivity within individual MSCs. Cellular morphology, cytoskeletal architecture, and cell motility were not markedly altered by IR. Even after high radiation doses up to 10 Gy, MSCs maintained their differentiation potential. Compared to primary fibroblast cells, MSCs did not show an increase in irradiation-induced apoptosis. Gene expression analyses revealed an upregulation of various genes involved in DNA damage response and DNA repair, but expression of established MSC surface markers appeared only marginally influenced by IR. Conclusions: These data suggest that human MSCs are not more radiosensitive than differentiated primary fibroblasts. In addition, upon photon irradiation, MSCs were able to retain their defining stem cell characteristics both on a functional level and regarding stem cell marker expression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Flow Cytometry DNA Damage Response Protein Activation Kinetics Following X-rays and High Energy Iron Nuclei Exposure

We developed a mathematical method to analyze flow cytometry data to describe the kinetics of {gamma}H2AX and pATF2 phosphorylations ensuing various qualities of low dose radiation in normal human fibroblast cells. Previously reported flow cytometry kinetic results for these DSB repair phospho-proteins revealed that distributions of intensity were highly skewed, severely limiting the detection of differences in the very low dose range. Distributional analysis reveals significant differences between control and low dose samples when distributions are compared using the Kolmogorov-Smirnov test. Radiation quality differences are found in the distribution shapes and when a nonlinear model is used to relate dose and time to the decay of the mean ratio of phosphoprotein intensities of irradiated samples to controls. We analyzed cell cycle phase and radiation quality dependent characteristic repair times and residual phospho-protein levels with these methods. Characteristic repair times for {gamma}H2AX were higher following Fe nuclei as compared to X-rays in G1 cells (4.5 {+-} 0.46 h vs 3.26 {+-} 0.76 h, respectively), and in S/G2 cells (5.51 {+-} 2.94 h vs 2.87 {+-} 0.45 h, respectively). The RBE in G1 cells for Fe nuclei relative to X-rays for {gamma}H2AX was 2.05 {+-} 0.61 and 5.02 {+-} 3.47, at 2 h and 24-h postirradiation, respectively. For pATF2, a saturation effect is observed with reduced expression at high doses, especially for Fe nuclei, with much slower characteristic repair times (>7 h) compared to X-rays. RBEs for pATF2 were 0.66 {+-} 0.13 and 1.66 {+-} 0.46 at 2 h and 24 h, respectively. Significant differences in {gamma}H2AX and pATF2 levels comparing irradiated samples to control were noted even at the lowest dose analyzed (0.05 Gy) using these methods of analysis. These results reveal that mathematical models can be applied to flow cytometry data to uncover important and subtle differences following exposure to various qualities of low dose radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Multifocal Glioblastoma Multiforme: Prognostic Factors and Patterns of Progression

Purpose: To assess the progression patterns in patients with multifocal glioblastoma multiforme who had undergone whole brain radiotherapy (WBRT), the historical standard, versus three-dimensional conformal radiotherapy, and to identify predictive treatment and pretreatment factors. Methods and Materials: The records of 50 patients with multifocal glioblastoma multiforme treated with RT were reviewed. Univariate analyses were performed using survival methods and the Cox proportional hazards regression method. Multivariate analyses were performed using the Cox proportional hazards regression method. Results: The mean age was 61 years, and 71% had a Karnofsky performance status (KPS) score of {>=}70. Of the 50 patients, 32% underwent WBRT and 68%, three-dimensional conformal RT. Progression was local in all evaluable patients, as determined by imaging in 38 patients and early neurologic progression in 12. The median time to progression (TTP) was 3.1 months, and the median survival time (MST) was 8.1 months. The significant independent predictors of TTP on multivariate analysis were a KPS score <70 (p = 0.001), the extent of surgery (p = 0.040), a radiation dose <60 Gy (p = 0.027), and the lack of chemotherapy (p = 0.001). The significant independent predictors of a reduced MST were a KPS score <70 (p = 0.022) and the absence of salvage surgery (p = 0.011) and salvage chemotherapy (p = 0.003). Conclusion: Local progression was observed in all patients. On multivariate analysis, no significant difference was found in the TTP or MST between three-dimensional conformal radiotherapy and WBRT. The KPS was a consistent independent predictor of both TTP and MST. On the basis of the progression pattern, we do not recommend WBRT as a mandatory component of the treatment of multifocal glioblastoma multi0011for.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 119}Sb--A potent Auger emitter for targeted radionuclide therapy

Auger electron emitting radionuclides in cancer therapy offer the opportunity to deliver a high radiation dose to the tumor cells with high radiotoxicity while minimizing toxicity to normal tissue. We have in this study identified the Auger emitter {sup 119}Sb as a potent nuclide for targeted radionuclide therapy based on theoretical dosimetry calculations at a subcellular scale. From these calculations we have determined the cellular S-values for this therapeutic isotope. Moreover, we have demonstrated the possibility of producing this isotope and also the SPECT-analogue {sup 117}Sb for patient-specific dosimetry, by measuring the proton irradiation yields for both isotopes using a low-energy cyclotron. The excellent SPECT imaging properties of the {sup 117}Sb radionuclide have been shown by scanning a Jaszczak SPECT Phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Review of Safety Assessment Issues at Savannah River Site, August 2011

At the request of Savannah River Nuclear Solutions (SRNS) management, a review team composed of experts in atmospheric transport modeling for environmental radiation dose assessment convened at the Savannah River Site (SRS) on August 29-30, 2011. Several issues were presented at the meeting for discussion. This is a short summary that is organized in accordance with the primary issues discussed, which is not necessarily a chronological record. Issues include: SRS Meteorological Data and its Use in MACCS2; Deposition Velocities for Particles; Deposition Velocities for Tritium; MACCS2 Dispersion Coefficients; Use of Low Surface Roughness in Open Areas; Adequacy of Meteorological Tower and Instrumentation; Displacement Height; and Validity of MACCS2 Calculations at Close-in Distances. A longer report will be issued at a later date that expands upon these topics and recommendations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗