Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructural and optical analysis of superresolution phenomena due to Ge{sub 2}Sb{sub 2}Te{sub 5} thin films at blue light regime

Superresolution (SR) phenomena due to Ge{sub 2}Sb{sub 2}Te{sub 5} films were examined by combined analysis of the transmission electron microscopy (TEM) microstructures of the laser-irradiated films and the results from dynamic and static tests using blue lasers. A new finding was made that comprises a complementary case of the classical SR readout by Ge{sub 2}Sb{sub 2}Te{sub 5} film; an amorphous band instead of a closed aperture of melt in the crystalline background forms behind a moving laser but still produces a high SR signal. A complete carrier-to-noise-ratio curve of a SR-read-only memory employing Ge{sub 2}Sb{sub 2}Te{sub 5} may be derived from a nonlinear optical effect, specifically thermally assisted saturable absorption.

36 MATERIALS SCIENCE↗

Current–phase relations of few-mode InAs nanowire Josephson junctions

Gate-tunable semiconductor nanowires with superconducting leads have great potential for quantum computation and as model systems for mesoscopic Josephson junctions. The supercurrent, I, versus the phase, Φ, across the junction is called the current–phase relation (CPR). It can reveal not only the amplitude of the critical current, but also the number of modes and their transmission. Here, we measured the CPR of many individual InAs nanowire Josephson junctions, one junction at a time. Both the amplitude and shape of the CPR varied between junctions, with small critical currents and skewed CPRs indicating few-mode junctions with high transmissions. In a gate-tunable junction, we found that the CPR varied with gate voltage: near the onset of supercurrent, we observed behaviour consistent with resonant tunnelling through a single, highly transmitting mode. The gate dependence is consistent with modelled subband structure that includes an effective tunnelling barrier due to an abrupt change in the Fermi level at the boundary of the gate-tuned region. These measurements of skewed, tunable, few-mode CPRs are promising both for applications that require anharmonic junctions and for Majorana readout proposals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

Transmural Remodeling of Cardiac Microstructure in Aged Spontaneously Hypertensive Rats by Diffusion Tensor MRI

The long-standing high blood pressure (also known as hypertension) overworks the heart. Microstructural remodeling is a key factor of hypertensive heart disease progression. Diffusion tensor magnetic resonance imaging (DT-MRI) is a powerful tool for the rapid noninvasive nondestructive delineation of the cardiomyocyte organization. The spontaneously hypertensive rat (SHR) is a well-established model of genetic hypertension. The goal of this study was to employ high-resolution DT-MRI and the SHR animal model to assess the transmural layer-specific remodeling of myocardial microstructure associated with hypertension. Ex vivo experiments were performed on excised formalin-fixed hearts of aged SHRs (n = 4) and age-matched controls (n = 4). The DT-MRI-derived fractional anisotropy (FA), longitudinal diffusivity (λ L ), transversal diffusivity (λ T ), and mean diffusivity (MD) served as the readout parameters investigated at three transmural zones (i.e., endocardium, mesocardium, and epicardium). The helix angles (HAs) of the aggregated cardiomyocytes and the orientation of laminar sheetlets were also studied. Compared with controls, the SHRs exhibited decreased epicardial FA, while FA changes in the other two transmural regions were insignificant. No substantial differences were observed in the diffusivity parameters and the transmural course of HAs between the two groups. A consistent distribution pattern of laminar sheetlet orientation was not identified for either group. Our findings are in line with the known cellular microstructure from early painstaking histological studies. Biophysical explanations of the study outcomes are provided. In conclusion, our experimental findings indicate that the epicardial microstructure is more vulnerable to high blood pressure leading to more pronounced changes in this region during remodeling. DT-MRI is well-suited for elucidating these alterations. The revealed transmural nonuniformity of myocardial reorganization may shed light on the mechanisms of the microstructure-function relationship in hypertension progression. Our results provide insights into the management of patients with systemic arterial hypertension, thus prevent the progression toward heart failure. The findings of this study should be acknowledged by electromechanical models of the heart that simulate the specific cardiac pathology.

60 APPLIED LIFE SCIENCES↗

Development of Thermal Infrared Sensor to Supplement Operational Land Imager

The thermal infrared sensor (TIRS) is a quantum well infrared photodetector (QWIP)-based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a far-infrared imager operating in the pushbroom mode with two IR channels: 10.8 and 12 m. The focal plane will contain three 640 ~512 QWIP arrays mounted onto a silicon substrate. The readout integrated circuit (ROIC) addresses each pixel on the QWIP arrays and reads out the pixel value (signal). The ROIC is controlled by the focal plane electronics (FPE) by means of clock signals and bias voltage value. The means of how the FPE is designed to control and interact with the TIRS focal plane assembly (FPA) is the basis for this work. The technology developed under the FPE is for the TIRS focal plane assembly (FPA). The FPE must interact with the FPA to command and control the FPA, extract analog signals from the FPA, and then convert the analog signals to digital format and send them via a serial link (USB) to a computer. The FPE accomplishes the described functions by converting electrical power from generic power supplies to the required bias power that is needed by the FPA. The FPE also generates digital clocking signals and shifts the typical transistor-to-transistor logic (TTL) to }5 V required by the FPA. The FPE also uses an application- specific integrated circuit (ASIC) named System Image, Digitizing, Enhancing, Controlling, And Retrieving (SIDECAR) from Teledyne Corp. to generate the clocking patterns commanded by the user. The uniqueness of the FPE for TIRS lies in that the TIRS FPA has three QWIP detector arrays, and all three detector arrays must be in synchronization while in operation. This is to avoid data skewing while observing Earth flying in space. The observing scenario may be customized by uploading new control software to the SIDECAR.

Shu, Peter↗

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology↗

Development of a Cryogen-Free Continuous ADR for the Constellation-X Mission

Constellation-X is a multi-satellite x-ray astronomy mission presently being planned for launch in the 2010 time frame. Each of 4 identical satellites will contain a telescope and instruments for imaging and spectroscopic analysis of both hard and soft x-rays. The X- ray Microcalorimeter Spectrometer (XMS) instrument will use arrays of microcalorimeters to detect X-rays with energies from 0.2 to 6 keV. The technologies under development for this instrument include Transition-Edge Sensors (TES) with multiplexed SQUID readouts and NTD-Ge detectors with JFET readouts. Both will be operated at temperatures in the 50-60 mK range and both have a projected cooling power requirement of approximately 5 microwatts. In addition, in order to meet the lifetime requirement of 6 years (with a goal of 10 years), a mechanical cryocooler will be used to provide a heat sink for the low temperature cooler. The required performance is 20 mW at 6 K, with a goal of 4 K operation. In this paper we present the development status of an adiabatic demagnetization refigerator (ADR) that meets the cooling requirements of the X M S instrument. At present we have demonstrated a 4-stage ADR that operates continuously at 50 mK using a 4.2 K helium bath as a heat sink. The cooling power is 21 microwatts at 100 mK and 6 microwatts at 50 mK. Its efficiency when operating at 50 mK is 1 1 % of Carnot (accounting for all dissipation at 4.2 K and below, but not including power dissipation in the room temperature electronics), but this is expected to rise to 25% in the next generation system in which active gas-gap heat switches are replaced with passive devices. This will reduce the peak heat rejection rate of the ADR to less than 7 mW at 6 K. Details of the ADR s design and operation, as well as the development program leading up to a flight-qualified instrument, will be discussed.

Shirron, Peter↗

First 3D vector tracking of helium recoils for fast neutron measurements at Super$\mathrm{KEKB}$

Here we present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed 3D imaging of ionization from neutron-induced nuclear recoils in a helium and carbon dioxide target gas mixture at standard temperature and pressure. We present the TPC performance and the neutron backgrounds observed during the initial stage of collider commissioning. We find excellent electron background rejection, leading to background-free nuclear recoil measurements above 50 keV ee , despite the extreme high-background environment. We measure an angular resolution better than 20° for recoil tracks longer than 1.7 mm, corresponding to an average ionization energy of approximately 100 keV ee . We also obtain the full 3D vector direction of helium recoils by utilizing charge profile measurements along the recoil axis, with a correct head/tail assignment efficiency of approximately 80%. With this performance, we present comparisons between measured and simulated event rates, recoil energy spectra, and directional distributions originating from beam–gas and Touschek beam losses at SuperKEKB. We utilize head/tail recognition to distinguish neutron components traveling with positive radial velocity in the Belle II coordinate system from those traveling in the opposite direction. Finally, we present a novel method of discriminating beam–gas interactions from Touschek beam losses that can eliminate the need for dedicated accelerator runs for background measurements. This method is still statistics-limited. However, future studies should be able to verify this method, which in turn could lead to neutron background analysis runs symbiotic with normal Belle II operation. The capabilities demonstrated here also suggest that high definition recoil imaging in gas TPCs is applicable to low energy, low-background experiments, such as directional dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic ray radiography of a human phantom

Cosmic ray muons that reach the earth's surface provide a natural source of radiation that is used for radiography. In this paper, we show that radiography using the cosmic radiation background provides a method that can be used to monitor bulk aspects of human anatomy. We describe a method that can be used to measure changes in patients as a function of time by cosmic ray muon radiography. Modeling shows muon tomography could provide hourly readouts of parameters such as lung density with sufficient sensitivity to detect the time changes in the inflammation of the lungs in, e.g., COVID patients.

60 APPLIED LIFE SCIENCES↗

Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters

We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.

Yoon, W.↗

Understanding Reliability Trade-Offs in 1T-nC and 2T-nC FeRAM Designs

Ferroelectric random access memory (FeRAM) is a promising candidate for energy-efficient nonvolatile memory, particularly for logic-in-memory and compute-in-memory (CIM) applications. Among the available cell architectures, One-Transistor–n-Capacitor (1T-nC) and two-transistor–n-capacitor (2T-nC) FeRAMs each offer distinct trade-offs in density, scalability, and reliability. In this work, we present a comparative study of these two architectures under both dimensional scaling ( XY/Z shrinkage) and vertical integration (increasing stacked capacitors per cell). Using technology computer-aided design (TCAD) and circuit-level simulations, we analyze how scaling impacts ferroelectric capacitance, parasitic coupling, and floating-node (FN) dynamics, which together dictate sense margin (SM) and read stability. A key mitigation strategy—floating unselected capacitors—is applied to both architectures, effectively decoupling the SM from the number of stacked capacitors and enabling tractable analysis across scaling regimes. Results show that 1T-nC suffers more from charge sharing with the bitline (BL), while 2T-nC benefits from transistor isolation and stronger low-voltage sensing at the cost of increased area. By systematically evaluating these behaviors across scaling directions, this work establishes the reliability trade-offs of 1T-nC and 2T-nC cells and provides design guidelines for high-density, vertically integrated FeRAM systems.

1T-nC↗

New read-out electronics for ICARUS-T600 liquid argon TPC. Description, simulation and tests of the new front-end and ADC system

Here, the ICARUS T600, a liquid argon time projection chamber (LAr-TPC) detector mainly devoted to neutrino physics, underwent a major overhauling at CERN in 2016-2017, which included also a new design of the read-out electronics, in view of its operation in Fermilab on the Short Baseline Neutrino (SBN) beam from 2019. The new more compact electronics showed capability of handling more efficiently the signals also in the intermediate Induction 2 wire plane with a significant increase of signal to noise (S/N), allowing for charge measurement also in this view. The new front-end and the analog to digital conversion (ADC) system are presented together with the results of the tests on 50 liters liquid argon TPC performed at CERN with cosmic rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-47: Development of a High-Precision, Image-Guided Radiotherapy, Multi- Purpose Radiation Isocenter Quality-Assurance Calibration and Checking System

Purpose: To develop a system that can define the radiation isocenter and correlate this information with couch coordinates, laser alignment, optical distance indicator (ODI) settings, optical tracking system (OTS) calibrations, and mechanical isocenter walkout. Methods: Our team developed a multi-adapter, multi-purpose quality assurance (QA) and calibration device that uses an electronic portal imaging device (EPID) and in-house image-processing software to define the radiation isocenter, thereby allowing linear accelerator (Linac) components to be verified and calibrated. Motivated by the concept that each Linac component related to patient setup for image-guided radiotherapy based on cone-beam CT should be calibrated with respect to the radiation isocenter, we designed multiple concentric adapters of various materials and shapes to meet the needs of MV and KV radiation isocenter definition, laser alignment, and OTS calibration. The phantom's ability to accurately define the radiation isocenter was validated on 4 Elekta Linacs using a commercial ball bearing (BB) phantom as a reference. Radiation isocenter walkout and the accuracy of couch coordinates, ODI, and OTS were then quantified with the device. Results: The device was able to define the radiation isocenter within 0.3 mm. Radiation isocenter walkout was within ±1 mm at 4 cardinal angles. By switching adapters, we identified that the accuracy of the couch position digital readout, ODI, OTS, and mechanical isocenter walkout was within sub-mm. Conclusion: This multi-adapter, multi-purpose isocenter phantom can be used to accurately define the radiation isocenter and represents a potential paradigm shift in Linac QA. Moreover, multiple concentric adapters allowed for sub-mm accuracy for the other relevant components. This intuitive and user-friendly design is currently patent pending.

07 ISOTOPE AND RADIATION SOURCES↗

Frequency Limitation Due to Switching Transition of the Bias Current in Bidirectional RSFQ Logic

Switching time limitations of the ac bias current of Josephson junctions in bidirectional rapid single flux quantum (RSFQ) logic circuits are investigated in order to determine the limits to the maximum possible operating frequency. We introduce a new approach based on modifying the bias current parameters and determining the inductance values in the circuit for reducing the switching transition time of the bias current through the junctions. We have simulated and optimized the timing and the operation of the bidirectional nondestructive readout and Josephson transmission line cells in this respect to demonstrate the results of utilizing the proposed approach. We successfully reduced the unwanted spike-type signals across the inductances which are made through the transitions during the fast switching times limiting the operation frequency. This is while we have also removed the consequent destructive spikes at the output. We have included the effects of other determining parameters of the circuit in this investigation and found their relatively optimal values to improve the temporal behavior of the bidirectional RSFQ cells. The results of the proposed approach leading to the fastest possible operation of the considered gates obtained in this work are thoroughly reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NT digital micro tape recorder

The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of intensive, multi-disciplinary research and development. What follows is a discussion of the technologies that have made the NT possible: (1) NT format mechanics, (2) NT media, (3) NT circuitry and board.

Sasaki, Toshikazu↗

The International Large Detector: Letter of Intent

The International Large Detector (ILD) is a concept for a detector at the International Linear Collider, ILC. The ILC will collide electrons and positrons at energies of initially 500 GeV, upgradeable to 1 TeV. The ILC has an ambitious physics program, which will extend and complement that of the Large Hadron Collider (LHC). The ILC physics case has been well documented, most recently in the ILC Reference Design Report, RDR. A hallmark of physics at the ILC is precision. The clean initial state and the comparatively benign environment of a lepton collider are ideally suited to high precision measurements. To take full advantage of the physics potential of ILC places great demands on the detector performance. The design of ILD, which is based on the GLD and the LDC detector concepts, is driven by these requirements. Excellent calorimetry and tracking are combined to obtain the best possible overall event reconstruction, including the capability to reconstruct individual particles within jets for particle flow calorimetry. This requires excellent spatial resolution for all detector systems. A highly granular calorimeter system is combined with a central tracker which stresses redundancy and efficiency. In addition, efficient reconstruction of secondary vertices and excellent momentum resolution for charged particles are essential for an ILC detector. The interaction region of the ILC is designed to host two detectors, which can be moved into the beam position with a 'push-pull' scheme. The mechanical design of ILD and the overall integration of subdetectors takes these operational conditions into account. The main features of ILD are outlined below. The central component of the ILD tracker is a Time Projection Chamber (TPC) which provides up to 224 precise measurements along the track of a charged particle. This is supplemented by a system of Silicon (Si) based tracking detectors, which provide additional measurement points inside and outside of the TPC, and extend the angular coverage down to very small angles. A Si-pixel based vertex detector (VTX) enables long lived particles such as b- and c-hadrons to be reconstructed. This combination of tracking devices, which has a large degree of redundancy, results in high track reconstruction efficiencies, and unprecedented momentum resolution and vertex reconstruction capabilities. One of the most direct measures of detector performance at the ILC is the jet-energy resolution. Precise di-jet mass reconstruction and separation of hadronically decaying W and Z bosons are essential for many physics channels. The ultimate jet energy resolution is achieved when every particle in the event, charged and neutral, is measured with the best possible precision. Within the paradigm of particle flow calorimetry, this goal is achieved by reconstructing charged particles in the tracker, photons in the electromagnetic calorimeter (ECAL), and neutral hadrons in the ECAL and hadronic calorimeter (HCAL). The ultimate performance is reached for perfect separation of charged-particle clusters from neutral particle clusters in the calorimeters. Thus, a highly granular calorimeter outside the tracker is the second key component of ILD. Sampling calorimeters with dense absorber material and fine grained readout are used. A tungsten absorber based electromagnetic calorimeter (ECAL) covers the first interaction length, followed by a somewhat coarser steel based sampling hadronic calorimeter (HCAL). Several ECAL and HCAL readout technologies are being pursued.

43 PARTICLE ACCELERATORS↗

Building Towards Discovery: Preparing for New Physics at the LHC [Final papers]

Particle physics today is at a crossroads. The Standard Model (SM) has survived four decades of experimental scrutiny and spurred multiple landmark discoveries, culminating with the 2012 discovery of the Higgs boson at the Large Hadron Collider (LHC). Yet we know that this model is incomplete. We live in a universe dominated by matter and energy unaccounted for by the SM– and the Higgs boson itself is improbably light. It falls to the current generation of high-energy physicists to go beyond the model and enter a new era of discovery. Andeen is leading a new research group at the University of Texas at Austin (UT-Austin) that is endeavoring to reveal novel physical phenomena through the discovery of new particles with the ATLAS detector at the LHC. A key element of our experience thus far has been collaborating closely with theorists to identify both interesting new physics models. In addition we work closely with electrical engineers in detector development. Our approach is therefore unique in its integration of theory, analysis and instrumentation, and is encapsulated in a three-pronged strategy. First is the essential task of analyzing our rapidly expanding dataset. I am directing my group in searches for vector-like quarks (VLQs). Should they exist, these hypothetical particles would indicate physics scenarios beyond the SM. Experimental constraints suggest VLQs decay preferentially to a third generation quark and a Higgs, W or Z boson. Today at 13 TeV, both multi-lepton (electron and muon) and jet substructure signatures are sensitive to identifying the VLQ decay products. The large Run 2 dataset (collected through 2018) of up to 150 fb -1 will allow us to simultaneously use multi-lepton signatures with jet-substructure in searches for new physics. UT-Austin is well positioned to be a leader in this area. Prof. P. Onyisi’s postdoctoral researchers and graduate students are searching for ttH signatures in three- and four-lepton channels and we benefit from their experience. We are also aided by the availability of the Texas Advanced Computing Center, which provides us with easy access to several high performance computing (HPC) systems. My previous experience in VLQ searches propels the work today. I have published both the first investigation into the single production of top partners (signatures of composite Higgs Models) of any LHC experiment 1 as well as one of the first analyses utilizing jet-substructure techniques to search for the single production of vector-like quarks. 2 Adding to this is my group’s work with the Liquid Argon (LAr) calorimeter, the primary instrument we use in detecting electrons. Second, my group is contributing to the operations of the LAr calorimeter while preparing to install and commission new electronic hardware (the Phase 1 upgrade) to this crucial component of the ATLAS detector. I have played a leading role in the development of a critical, radiation-hard, high-speed Analog-to-Digital Convertor (ADC) that is essential inselecting data collected by the LAr calorimeter. 3 This upgrade will improve the e!ciency with which we can select events in our detector. Postdoctoral researcher N. Nikiforou (based at CERN May 2016 onward) and graduate students (one based at CERN from the start of 2018 onward, with one additional graduate students from summer 2018) are growing our already deep experience in the operation of the LAr calorimeter to prepare for installation and commissioning of the new trigger readout in 2018-2019. My group will then be positioned to be the first to exploit the potential of the improved triggers in our multi-lepton searches for new physics. Third, a suite of preparations for a major detector upgrade, scheduled to be completed in 2024, are underway. My group is building hardware that will improve the electronic readout of the ATLAS detector. I am partnering with a group in the Electrical and Computer Engineering (ECE) Department at UT-Austin (Prof. N. Sun) to employ his work at the cutting edge of ADC research. We will support an ECE grad student for the layout of this design, and collaborate with engineering groups at Nevis Laboratory and the Electrical Engineering Department (Prof. P. Kinget) at Columbia University to integrate our ADC with gain selection circuits. We will provide this critical component of the ASIC at the challenging boundary of the analog and digital signals in the LAr calorimeter readout chain. Furthermore UT-Austin will lead the testing of this device during development and production (approximately 55,000 four-channel chips). This effort compliments my work as the deliverables manager for the LAr front-end ASICs for the US ATLAS HL-LHC project and strengthens the US commitment to that upgrade.In so doing, my group at the UT-Austin will be at the forefront of efforts to probe the structure of the universe to an unmatched degree both at the current LHC and with its future upgrades. Through both the ongoing analysis of data at the ATLAS detector and improvements to the detector itself, an answer to what lies beyond the SM may come within our grasp. My background in instrumentation and analysis allows my group to establish a singular research effort on the ATLAS experiment. In addition to answering fundamental questions about the subatomic world, the technologies developed could advance the broader scientific community and result in valuable spin-offs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗