Search NASA⌕ Search

SEARCH · Search NASA

Results for “Random effect model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Development of an Exactly Solvable Model of Resonance Tunneling of Electromagnetic Waves through Gradient Barriers in a Nonuniform Magnetoactive Plasma

An exactly solvable one-dimensional model describing resonance tunneling (reflectionless transmission) of a transverse electromagnetic wave through wide layers of magnetoactive plasma is developed on the basis of the Helmholtz equation. The plasma layers include a set of spatially localized density structures the amplitudes and thicknesses of which are such that approximate methods are inapplicable for their analysis. The profiles of the plasma density structures strongly depend on the choice of the free parameters of the problem that determine the amplitudes of plasma density modulation, characteristic scale lengths of the density structures, their number, and the total thickness of the nonuniform plasma layer. The plasma layers can also include a set of random inhomogeneities. The propagation of electromagnetic waves through such complicated plasma inhomogeneities is analyzed numerically within the proposed exactly solvable model. According to calculations, there are a wide set of inhomogeneous structures for which an electromagnetic wave incident from vacuum can propagate through the plasma layer without reflection, i.e., the complete tunneling of thick plasma barriers takes place. The model also allows one to exactly solve a one-dimensional problem on the nonlinear transillumination of a nonuniform plasma layer in the presence of cubic nonlinearity. It is important that, due to nonlinearity, the thicknesses of the evanescent plasma regions can decrease substantially and, at a sufficiently strong nonlinearity, such regions will disappear completely. The problem of resonance tunneling of electromagnetic radiation through gradient wave barriers is of interest for various applications, such as efficient heating of dense plasma by electromagnetic radiation and transmission of electromagnetic signals from a source located in the near-Earth plasma or deep in the plasma of an astrophysical object through the surrounding evanescent regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A data-driven global soil heterotrophic respiration dataset and the drivers of its inter-annual variability

Soil heterotrophic respiration (SHR), one of the primary carbon fluxes from terrestrial ecosystems to the atmosphere, is important for carbon-climate feedbacks because of its sensitivity to available litter and soil carbon, climatic conditions, and nutrient availability. However, until recently limited SHR data were available, and most published global SHR estimates have either a short time span, coarse spatial resolution, or reply on overly-simple model formulations. To better understand and quantify the global distribution of SHR and its sensitivity to climate variability, we produced a new global SHR dataset using Random Forest algorithms, up-scaling 455 point data from the Global Soil Respiration Database (SRDB 4.0) with gridded fields of climatic, edaphic and productivity as explanatory variables. We estimated a global total SHR of 46.8 Pg C yr-1 over 1985-2013 (95% confidence interval: 38.6-56.3 Pg C yr-1), with a significant increasing trend of 0.03 Pg C yr-2 during this period. We found that the choice of soil moisture datasets contributes more to the difference among these data-driven SHR members rather than that of productivity, temperature and precipitation data sources. We also analyzed the influence of climatic variables on the inter-annual variability (IAV) of our SHR product. Water availability was the dominant driver of IAV at global scales, although the inferred sensitivity depends on the choice of the soil moisture gridded dataset. At the ecosystem scale, temperature strongly controls the IAV of SHR in tropical forests, while water availability dominates in extra-tropical forest and semi-arid regions. Our machine-learning gridded SHR dataset and outputs from process-based land surface models (TRENDYv6) show agreement for a strong association between water variability and SHR IAV at the global scale, but the two approaches lead to different temporal trend globally and different controlling variables for IAV at the ecosystem scale. Our study provides evidence for the pervasive and important role of water availability in driving SHR, indicating both a direct effect limiting decomposition rates and an indirect effect through the amount of fresh organic matter made available to SHR from productivity. In consideration of potential limitations and uncertainties remaining in our data-driven SHR datasets, we call for a more scientifically designed observation network for SHR, more observation data compilation, and increased use of deep learning methods making maximum use of observation data in hand. This will benefit process-based models, and improve our understanding of SHR response to future anomalous environmental conditions.

Yao, Yitong↗

Broad band simulation of Gamma Ray Bursts (GRB) prompt emission in presence of an external magnetic field

The origin of prompt emission in GRBs is not yet well understood. The simplest and most popular model is Synchrotron Self-Compton (SSC) emission produced by internal shocks inside an ultra-relativistic jet. However, recent observations of a delayed high energy component by the Fermi-LAT instrument have encouraged alternative models. Here we use a recently developed formulation of relativistic shocks for GRBs to simulate light curves and spectra of synchrotron and self-Compton emissions in the framework of internal shock model. This model takes into account the evolution of quantities such as densities of colliding shells, and fraction of kinetic energy transferred to electrons and to induced magnetic field. We also extend this formulation by considering the presence of a precessing external magnetic field. These simulations are very realistic and present significant improvement with respect to previous phenomenological GRB simulations. They reproduce light curves of separate peaks of real GRBs and variety of spectral slopes at E > E{sub peak} observed by the Fermi-LAT instrument. The high energy emission can be explained by synchrotron emission and a subdominant contribution from inverse Compton. We also suggest an explanation for extended tail emission and relate it to the screening of the magnetic field and/or trapping of accelerated electrons in the electromagnetic energy structure of the plasma in the shock front. Spectral slopes of simulated bursts at E << E{sub peak} are consistent with theoretical prediction and at E < E{sub peak} can be flatter if the spectrum of electrons is roughly flat or has a shallow slope at low energies. The observed flat spectra at soft gamma-ray and hard x-ray bands is the evidence that there is a significant contribution at E < E{sub peak} from lower Lorentz factor wing of electron distribution which have a roughly random acceleration rather than being thermal. This means that the state of matter in the jet at the time of ejection is most probably nonthermal. As for the effect of a precessing external magnetic field, we show that due to the fast variation of other quantities, its signature in the Power Distribution Spectrum (PDS) is significantly suppressed and only when the duration of the burst is few times longer than the oscillation period it can be detected, otherwise either it is confused with the Poisson noise or with intrinsic variations of the emission. Therefore, low significant oscillations observed in the PDS of GRB 090709a are most probably due to a precessing magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting Intensive Care Unit Length of Stay and Mortality Using Patient Vital Signs: Machine Learning Model Development and Validation

Background: Patient monitoring is vital in all stages of care. In particular, intensive care unit (ICU) patient monitoring has the potential to reduce complications and morbidity, and to increase the quality of care by enabling hospitals to deliver higher-quality, cost-effective patient care, and improve the quality of medical services in the ICU. Objective: We here report the development and validation of ICU length of stay and mortality prediction models. The models will be used in an intelligent ICU patient monitoring module of an Intelligent Remote Patient Monitoring (IRPM) framework that monitors the health status of patients, and generates timely alerts, maneuver guidance, or reports when adverse medical conditions are predicted. Methods: We utilized the publicly available Medical Information Mart for Intensive Care (MIMIC) database to extract ICU stay data for adult patients to build two prediction models: one for mortality prediction and another for ICU length of stay. For the mortality model, we applied six commonly used machine learning (ML) binary classification algorithms for predicting the discharge status (survived or not). For the length of stay model, we applied the same six ML algorithms for binary classification using the median patient population ICU stay of 2.64 days. For the regression-based classification, we used two ML algorithms for predicting the number of days. We built two variations of each prediction model: one using 12 baseline demographic and vital sign features, and the other based on our proposed quantiles approach, in which we use 21 extra features engineered from the baseline vital sign features, including their modified means, standard deviations, and quantile percentages. Results: We could perform predictive modeling with minimal features while maintaining reasonable performance using the quantiles approach. The best accuracy achieved in the mortality model was approximately 89% using the random forest algorithm. The highest accuracy achieved in the length of stay model, based on the population median ICU stay (2.64 days), was approximately 65% using the random forest algorithm. Conclusions: The novelty in our approach is that we built models to predict ICU length of stay and mortality with reasonable accuracy based on a combination of ML and the quantiles approach that utilizes only vital signs available from the patient’s profile without the need to use any external features. This approach is based on feature engineering of the vital signs by including their modified means, standard deviations, and quantile percentages of the original features, which provided a richer dataset to achieve better predictive power in our models.

59 BASIC BIOLOGICAL SCIENCES↗

SIMULATED FARADAY ROTATION MEASURES TOWARD HIGH GALACTIC LATITUDES

We study the Faraday rotation measure (RM) due to the Galactic magnetic field (GMF) toward high Galactic latitudes. The RM arises from the global, regular component as well as from the turbulent, random component of the GMF. We model the former based on observations and the latter using the data of magnetohydrodynamic turbulence simulations. For a large number of different GMF models, we produce mock RM maps around the Galactic poles and calculate various statistical quantities with the RM maps. We find that the observed medians of RMs toward the north and south Galactic poles, {approx}0.0 {+-} 0.5 rad m{sup -2} and {approx} + 6.3 {+-} 0.5 rad m{sup -2}, are difficult to explain with any of our many alternate GMF models. The standard deviation of observed RMs, {approx}9 rad m{sup -2}, is clearly larger than that of simulated RMs. The second-order structure function of observed RMs is substantially larger than that of simulated RMs, especially at small angular scales. We discuss other possible contributions to RM toward high Galactic latitudes. Besides observational errors and the intrinsic RM of background radio sources against which RM is observed, we suggest that the RM due to the intergalactic magnetic field may account for a substantial fraction of the observed RM. Finally, we note that reproducing the observed medians may require additional components or/and structures of the GMF that are not present in our models.

79 ASTRONOMY AND ASTROPHYSICS↗

Temporal regulation of cold transcriptional response in switchgrass

Switchgrass low-land ecotypes have significantly higher biomass but lower cold tolerance compared to up-land ecotypes. Understanding the molecular mechanisms underlying cold response, including the ones at transcriptional level, can contribute to improving tolerance of high-yield switchgrass under chilling and freezing environmental conditions. Here, by analyzing an existing switchgrass transcriptome dataset, the temporal cis- regulatory basis of switchgrass transcriptional response to cold is dissected computationally. We found that the number of cold-responsive genes and enriched Gene Ontology terms increased as duration of cold treatment increased from 30 min to 24 hours, suggesting an amplified response/cascading effect in cold-responsive gene expression. To identify genomic sequences likely important for regulating cold response, machine learning models predictive of cold response were established using k -mer sequences enriched in the genic and flanking regions of cold-responsive genes but not non-responsive genes. These k -mers, referred to as putative cis -regulatory elements (pCREs) are likely regulatory sequences of cold response in switchgrass. There are in total 655 pCREs where 54 are important in all cold treatment time points. Consistent with this, eight of 35 known cold-responsive CREs were similar to top-ranked pCREs in the models and only these eight were important for predicting temporal cold response. More importantly, most of the top-ranked pCREs were novel sequences in cold regulation. Our findings suggest additional sequence elements important for cold-responsive regulation previously not known that warrant further studies.

60 APPLIED LIFE SCIENCES↗

Combination Therapy of Transcatheter Arterial Chemoembolization and Arterial Administration of Antiangiogenesis on VX2 Liver Tumor

Purpose: This study was designed to evaluate the antitumorigenic efficiency of Endostar (an antiangiogenic agent) arterially administrated combined with transcatheter arterial chemoembolization (TACE) on liver tumor, and validation of perfusion CT for quantitative measurements of the results.Experimental DesignThirty rabbits bearing VX2 liver tumors were randomly and equally distributed into three groups. One of the following treatment protocols was performed in each group: 1) group 1 was treated with TACE and simultaneously arterially administrated Endostar; 2) group 2 with TACE alone, and 3) a control group that had saline injected through hepatic artery. Routine CT scan was performed before treatment, and perfusion CT imaging was performed 2 weeks after treatment. Immunohistochemical biomarkers of microvascular density (MVD) and the expression of vascular endothelial growth factor (VEGF) were measured for assessments of angiogenesis. Results: We observed a statistically significant reduction from the control in the volume, growth rate, and size of the tumor 2 weeks after treatment with both TACE plus Endostar and with TACE alone (P < 0.01). Although there was no statistically significant difference in tumor size between the group with TACE plus Endostar and the group with TACE alone (P > 0.05), MVD and VEGF were significantly less expressed in the TACE plus Endostar group than both groups with TACE alone and the control group (P < 0.01). Blood flow (BF), blood volume (BV), and permeability-surface area products (PS) in the group with TACE plus Endostar on perfusion CT were significantly higher than other two groups (P < 0.05), which were positively correlated with the MVD and VEGF values (P < 0.05). Conclusions: TACE with arterial administration of Endostar simultaneously significantly inhibited the angiogenesis biomarkers associated with TACE in a rabbit model bearing VX2 liver tumor, which indicates that the combined treatment protocol may have potential synergistic effects on liver cancer. It also is suggested that perfusion CT may be useful for monitoring antiangiogenic/antivascular treatment in the liver tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RADII OF RAPIDLY ROTATING STARS, WITH APPLICATION TO TRANSITING-PLANET HOSTS

The currently favored method for estimating radii and other parameters of transiting-planet host stars is to match theoretical models to observations of the stellar mean density rho{sub *}, the effective temperature T{sub eff}, and the composition parameter [Z]. This explicitly model-dependent approach is based on readily available observations, and results in small formal errors. Its performance will be central to the reliability of results from ground-based transit surveys such as TrES, HAT, and SuperWASP, as well as to the space-borne missions MOST, CoRoT, and Kepler. Here, I use two calibration samples of stars (eclipsing binaries (EBs) and stars for which asteroseismic analyses are available) having well-determined masses and radii to estimate the accuracy and systematic errors inherent in the rho{sub *} method. When matching to the Yonsei-Yale stellar evolution models, I find the most important systematic error results from selection bias favoring rapidly rotating (hence probably magnetically active) stars among the EB sample. If unaccounted for, this bias leads to a mass-dependent underestimate of stellar radii by as much as 4% for stars of 0.4 M{sub sun}, decreasing to zero for masses above about 1.4 M{sub sun}. Relative errors in estimated stellar masses are three times larger than those in radii. The asteroseismic sample suggests (albeit with significant uncertainty) that systematic errors are small for slowly rotating, inactive stars. Systematic errors arising from failings of the Yonsei-Yale models of inactive stars probably exist, but are difficult to assess because of the small number of well-characterized comparison stars having low mass and slow rotation. Poor information about [Z] is an important source of random error, and may be a minor source of systematic error as well. With suitable corrections for rotation, it is likely that systematic errors in the rho{sub *} method can be comparable to or smaller than the random errors, yielding radii that are accurate to about 2% for most stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantifying the Effect of Lidar Turbulence Error on Wind Power Prediction

Currently, cup anemometers on meteorological towers are used to measure wind speeds and turbulence intensity to make decisions about wind turbine class and site suitability; however, as modern turbine hub heights increase and wind energy expands to complex and remote sites, it becomes more difficult and costly to install meteorological towers at potential sites. As a result, remote-sensing devices (e.g., lidars) are now commonly used by wind farm managers and researchers to estimate the flow field at heights spanned by a turbine. Although lidars can accurately estimate mean wind speeds and wind directions, there is still a large amount of uncertainty surrounding the measurement of turbulence using these devices. Errors in lidar turbulence estimates are caused by a variety of factors, including instrument noise, volume averaging, and variance contamination, in which the magnitude of these factors is highly dependent on measurement height and atmospheric stability. As turbulence has a large impact on wind power production, errors in turbulence measurements will translate into errors in wind power prediction. The impact of using lidars rather than cup anemometers for wind power prediction must be understood if lidars are to be considered a viable alternative to cup anemometers.In this poster, the sensitivity of power prediction error to typical lidar turbulence measurement errors is assessed. Turbulence estimates from a vertically profiling WINDCUBE v2 lidar are compared to high-resolution sonic anemometer measurements at field sites in Oklahoma and Colorado to determine the degree of lidar turbulence error that can be expected under different atmospheric conditions. These errors are then incorporated into a power prediction model to estimate the sensitivity of power prediction error to turbulence measurement error. Power prediction models, including the standard binning method and a random forest method, were developed using data from the aeroelastic simulator FAST for a 1.5 MW turbine. The impact of lidar turbulence error on the predicted power from these different models is examined to determine the degree of turbulence measurement accuracy needed for accurate power prediction.

17 WIND ENERGY↗

Parasitic Modulation of Microwave Signals by a Hypersonic Plasma Layer

During hypersonic flight, compressional and viscous heating of the air can form a plasma layer which encases the aircraft. If the boundary layer becomes turbulent, then the electron density fluctuations can effect a parasitic modulation in microwave signals transmitted through the plasma. We developed an approach for studying the interaction of microwave signals with a turbulent, hypersonic plasma layer. The approach affords a great deal of flexibility in both the plasma layer model and the antenna configuration. We then analyzed a situation in which microwaves, transmitted from a rectangular aperture antenna, propagate through a turbulent plasma layer to a distant receiver. We characterized the first-and second-order statistics of the computed parasitic modulation and quantified the depolarization of the signal. The amplitude fluctuations are lognormally distributed at low frequencies and Rice-distributed at high frequencies. Fluctuations in the copolarized phase and amplitude of the far-field signal are strongly anticorrelated. Here, we used a multioutput Gaussian process (MOGP) to model these quantities. The efficacy of the MOGP model is demonstrated by recovering the time evolution of the copolarized phase given the copolarized amplitude and occasional measurements of the phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupled Serial and Parallel Non-uniform SQUIDs

In this work we numerical model series and parallel non-uniform superconducting quantum interference device (SQUID) array. Previous work has shown that series SQUID array constructed with a random distribution of loop sizes, (i.e. different areas for each SQUID loop) there exists a unique 'anti-peak' at the zero magnetic field for the voltage versus applied magnetic field (V-B). Similar results extend to a parallel SQUID array where the difference lies in the arrangement of the Josephson junctions. Other system parameter such as bias current, the number of loops, and mutual inductances are varied to demonstrate the change in dynamic range and linearity of the V-B response. Application of the SQUID array as a low noise amplifier (LNA) would increase link margins and affect the entire communication system. For unmanned aerial vehicles (UAVs), size, weight and power are limited, the SQUID array would allow use of practical 'electrically small' antennas that provide acceptable gain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pharmacokinetic Evaluation of Two Paclitaxel-Coated Balloons with Different Drug Load in a Short-Term Porcine Study

PurposeThe aim of the study was to evaluate the pharmacokinetics and tissue absorption of 2 paclitaxel (PTX) drug-coated balloons (DCB) using different drug loads in a porcine-injured iliac artery model.Materials and MethodsTwenty-eight pigs were randomized into 2 groups. In group B1, angioplasty was performed with a 1.0 µg/mm{sup 2} DCB with PTX and in group B3, with a 3.0 µg/mm{sup 2} DCB with PTX. An overstretched model of the iliac artery was used for angioplasty under fluoroscopy. Blood and vessel wall PTX were measured with liquid-chromatography mass spectrometry at 1, 5, 30 min, 1, 7, and 28 days. Remaining drug in the balloon was analyzed.ResultsMean PTX in blood was significantly higher in the group B3 0.269 ± 0.085 µg/ml compared with the B1 0.218 ± 0.085 µg/ml; p = 0.01. Peak blood PTX concentration was detected at 1 min, and PTX was undetectable 24 h post-angioplasty. There were no statistically significant differences in the mean arterial wall concentration from the treated iliac artery between group-B1 (15.24 ± 21.29 ng/mg) and B3 (15.68 ± 16.33 ng/mg), or in the PTX wall concentration measured at different time points. Mean remaining drug in assayed balloons was lower for group-B1 and represented 8 % of the initial dose.ConclusionsBlood PTX was higher when using 3.0 µg/mm{sup 2} DCB, with a peak drug concentration at 1-min, although the drug was undetectable at 24 h, independently of the loading dose. This study demonstrates no difference in arterial wall uptake of a low dose DCB (1.0 µg/mm{sup 2}), when compared to a common dose DCB (3.0 µg/mm{sup 2}) suggesting that the dose of drug in the DCB could be reduced obtaining a similar clinical effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystal-field analysis and Zeeman splittings of energy levels of Nd{sup 3+} (4f{sup 3}) in GaN

The crystal-field splitting and Zeeman splitting of energy levels of Nd{sup 3+} (4f{sup 3}) doped into semi-conducting GaN (3.2 eV) grown in the hexagonal (huntite) phase by plasma-assisted molecular beam epitaxy have been modeled using a parameterized Hamiltonian defined to operate within the complete 4f{sup 3} electronic configuration of Nd{sup 3+} substituted for Ga{sup 3+} in the lattice. Zeeman splittings were obtained by applying magnetic fields up to 6.6 T with the fields parallel and perpendicular to the crystallographic c-axis. The experimental energy (Stark) levels were obtained from a recent spectroscopic study on the same samples, where the combined excitation emission spectroscopy (CEES) identified the majority of Nd{sup 3+} ions as replacing Ga{sup 3+} in sites of C{sub 3v} symmetry. The manifolds of Nd{sup 3+} (4f{sup 3}){sup 2S+1}L{sub J} modeled for the crystal-field splitting include the ground state, {sup 4}I{sub 9/2}, and excited states {sup 4}I{sub 11/2}, {sup 4}I{sub 13/2}, {sup 4}F{sub 3/2}, {sup 4}F{sub 5/2}, {sup 2}H{sub 9/2}, {sup 4}F{sub 7/2}, {sup 4}S{sub 3/2}, {sup 4}G{sub 5/2}, and {sup 4}G{sub 7/2}. The energies of 41 experimental Stark levels from these manifolds were modeled through the use of a Monte Carlo method in which independent crystal-field parameters (CFP) were given random starting values and optimized using standard least-squares fitting between calculated and experimental Stark levels. Irreducible representations (irreps) and crystal field quantum numbers ({mu}) were assigned to the energy level states of the {sup 4}I{sub 9/2} and {sup 4}F{sub 3/2} multiplet manifolds based on an analysis of the Zeeman data. This allows determination of which of the competing local minima should be considered to be the physically significant minimum. Using standard least-squares fitting between calculated and experimental Stark levels for Nd{sup 3+} in C{sub 3v} symmetry, we obtain a final standard deviation of 7.01 cm{sup -1} (rms = 5.48 cm{sup -1}).

36 MATERIALS SCIENCE↗

Tuning the DARHT Axis-II linear induction accelerator focusing

Flash radiography of large hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories, and the Dual-Axis Radiography for Hydrodynamic Testing (DARHT) facility at Los Alamos produces flash radiographs of large hydrodynamic experiments. Two linear induction accelerators (LIAs) make the bremsstrahlung radiographic source spots for orthogonal views of each test. The 2-kA, 20-MeV Axis-I LIA creates a single 60-ns radiography pulse. The 1.7-kA, 16.5-MeV Axis-II LIA creates up to four radiography pulses by kicking them out of a longer pulse that has a 1.6-μs flattop. The Axis-II injector, LIA, kicker, and downstream transport (DST) to the bremsstrahlung converter are described. Adjusting the magnetic focusing and steering elements to optimize the electron-beam transport through an LIA is often called 'tuning.' As in all high-current LIAs, the focusing field is designed to be as close to that of the ideal continuous solenoid as physically possible. In ideal continuous solenoidal transport a smoothly varying beam size can easily be found for which radial forces balance, and the beam is said to be 'matched' to the focusing field. A 'mismatched' beam exhibits unwanted oscillations in size, which are a source of free energy that contributes to emittance growth. This is undesirable, because in the absence of beam-target effects, the radiographic spot size is proportional to the emittance. Tuning the Axis-II LIA is done in two steps. First, the solenoidal focusing elements are set to values designed to provide a matched beam with little or no envelope oscillations, and little or no beam-breakup (BBU) instability growth. Then, steering elements are adjusted to minimize the motion of the centroid of a well-centered beam at the LIA exit. This article only describes the design of the tune for the focusing solenoids. The DARHT Axis-II LIA was required to be re-tuned after installing an accelerator cell to replace a failed solenoid in March of 2012. We took advantage of this opportunity to improve the design of the focusing tune with better models of the remaining partially failed solenoids, better estimates of beam initial conditions, and better values for pulsed-power voltages. As with all previous tunes for Axis-II, this one incorporates measures to mitigate beam-breakup (BBU) instability, image displacement instability (IDI), corkscrew (sweep), and emittance growth. Section II covers the general approach to of design of focusing solenoid tunes for the DARHT Axis-2 LIA. Section III explains the specific requirements and simulations needed to design the tune for the injector, which includes the thermionic electron source, diode, and six induction cells. Section IV explains the requirements and simulations for tuning the main accelerator, which consists of 68 induction cells. Finally, Section V explores sensitivity of the tune to deviations of parameters from nominal, random variations, and uncertainties in values. Four appendices list solenoid settings for this new tune, discuss comparisons of different simulation codes, show halo formation in mismatched beams, and present a brief discussion of the beam envelope equation, which is the heart of the method used to design LIA solenoid tunes.

43 PARTICLE ACCELERATORS↗

SU-D-BRA-06: Dual-Energy Chest CT: The Effects of Virtual Monochromatic Reconstructions On Texture Analysis Features

Purpose: To characterize the effect of virtual monochromatic reconstructions on several commonly used texture analysis features in DECT of the chest. Further, to assess the effect of monochromatic energy levels on the ability of these textural features to identify tissue types. Methods: 20 consecutive patients underwent chest CTs for evaluation of lung nodules using Siemens Somatom Definition Flash DECT. Virtual monochromatic images were constructed at 10keV intervals from 40–190keV. For each patient, an ROI delineated the lesion under investigation, and cylindrical ROI’s were placed within 5 different healthy tissues (blood, fat, muscle, lung, and liver). Several histogram- and Grey Level Cooccurrence Matrix (GLCM)-based texture features were then evaluated in each ROI at each energy level. As a means of validation, these feature values were then used in a random forest classifier to attempt to identify the tissue types present within each ROI. Their predictive accuracy at each energy level was recorded. Results: All textural features changed considerably with virtual monochromatic energy, particularly below 70keV. Most features exhibited a global minimum or maximum around 80keV, and while feature values changed with energy above this, patient ranking was generally unaffected. As expected, blood demonstrated the lowest inter-patient variability, for all features, while lung lesions (encompassing many different pathologies) exhibited the highest. The accuracy of these features in identifying tissues (76% accuracy) was highest at 80keV, but no clear relationship between energy and classification accuracy was found. Two common misclassifications (blood vs liver and muscle vs fat) accounted for the majority (24 of the 28) errors observed. Conclusion: All textural features were highly dependent on virtual monochromatic energy level, especially below 80keV, and were more stable above this energy. However, in a random forest model, these commonly used features were able to reliably differentiate between most tissues types regardless of energy level. Dr Godoy has received a dual-energy CT research grant from Siemens Healthcare. That grant did not directly fund this research.

60 APPLIED LIFE SCIENCES↗

Rescattering photoelectron spectroscopy of the CO 2 molecule: Progress towards experimental discrimination between theoretical target-structure models

Photoelectron momentum distributions (PEMDs) generated in strong-field ionization of randomly oriented CO 2 molecules by intense infrared laser pulses at 1300-, 1450-, and 1650-nm wavelengths are measured experimentally and analyzed theoretically. Here, the experimental PEMDs extracted along the outermost backward rescattering caustic are well reproduced by theoretical calculations based on the recently derived factorization formula with an analytical returning photoelectron wave packet (RWP). The sensitivity of the theoretical results to the target structure models used in the calculations is investigated. It is shown that RWPs obtained in the single-active-electron (SAE) approximation and by the Hartree-Fock method have only minor differences. On the other hand, differential cross sections (DCSs) for elastic scattering of a photoelectron on the parent molecular ion calculated by ab initio , SAE, and independent-atom model methods are considerably different. This difference almost disappears after averaging over molecular orientations, so the present experiment does not enable us to discriminate between the different target structure models. However, we show that such a discrimination should become possible by measuring PEMD with aligned molecules. This will provide an access to the rich target structure information contained in the DCS.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mineral Deposition on the Rough Walls of a Fracture

Modeling carbonate growth in fractures and pores is important for understanding carbon sequestration in the environment or when supersaturated solutions are injected into rocks. Here, we study the simple but nontrivial problem of calcite growth on fractures with rough walls of the same mineral using kinetic Monte Carlo simulations of attachment and detachment of molecules and scaling approaches. First, we consider wedge-shaped fracture walls whose upper terraces are in the same low-energy planes and show that the valleys are slowly filled by the propagation of parallel monolayer steps in the wedge sides. The growth ceases when the walls reach these low-energy configurations so that a gap between the walls may not be filled. Second, we consider fracture walls with equally separated monolayer steps (vicinal surfaces with roughness below 1 nm) and show that growth by step propagation will eventually clog the fracture gap. In both cases, scaling approaches predict the times to attain the final configurations as a function of the initial geometry and the step-propagation velocity, which is set by the saturation index. The same reasoning applied to a random wall geometry shows that step propagation leads to lateral filling of surface valleys until the wall reaches the low-energy crystalline plane that has the smallest initial density of molecules. Thus, the final configurations of the fracture walls are much more sensitive to the crystallography than to the roughness or the local curvature. The framework developed here may be used to determine those configurations, the times to reach them, and the mass of deposited mineral. Effects of transport limitations are discussed when the fracture gap is significantly narrowed.

calcite↗

Contributions to the BeEST sterile neutrino search

Sterile neutrinos are hypothetical right-handed leptons that have been postulated as extensions to the Standard Model to help explain the origin of neutrino masses and the matter-antimatter asymmetry in the Universe. Sterile neutrinos with keV-scale masses are also a promising candidate for dark matter. LLNL and the Colorado School of Mines are developing an experiment to search for sterile neutrinos by measuring the \Beryllium-7 Electron capture in Superconducting Tunnel junctions (STJs)" (the \BeEST" Experiment). When 7 Be implanted into STJ radiation detectors decays by electron capture, the neutrino escapes and the energy of the recoiling 7 Li nucleus can be measured with high accuracy. Using conservation of energy and momentum, the mass of the emitted neutrino can then be found. Sterile keV neutrinos would generate additional peaks in the spectrum, and the experiment uses high-resolution STJs to observe such a potential signal. During my internship, I contributed to different aspects of the BeEST experiment. I designed a UHV setup for X-ray spectroscopy analysis with STJs. It will allow high-resolution X-ray spectroscopy of different materials to examine the broadening in the BeEST spectra, the origins of which are unknown but may be related to material effects inside the STJ detectors. The design accounts for the specific demands of the BeEST project, but provides a degree of flexibility that makes it useful for other potential STJ projects. Additionally, to test the accuracy of the electronics and data analysis routine, an arbitrary waveform generator (AWG) will be used to generate simulated spectra that contain sterile neutrino signals of a specified mass and admixture. For this I programmed an AWG to output random STJ signals whose amplitudes follow the appropriate user-de ned probability distribution. The AWG signals can be input into the 32-channel preamplifier to simulate any spectrum of interest and test the uniformity of the amplifier chain, as well as the sensitivity of the data analysis.

42 ENGINEERING↗