Search NASA⌕ Search

SEARCH · Search NASA

Results for “STRIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Recovery of critical elements from end-of-life lithium ion batteries with supported membrane solvent extraction

Single-stage and multi-stage systems and methods for the recovery of critical elements in substantially pure form from lithium ion batteries are provided. The systems and methods include supported membrane solvent extraction using an immobilized organic phase within the pores of permeable hollow fibers. The permeable hollow fibers are contacted by a feed solution on one side, and a strip solution on another side, to provide the simultaneous extraction and stripping of elements from dissolved lithium ion cathode materials, while rejecting other elements from the feed solution. The single- and multi-stage systems and methods can selectively recover cobalt, manganese, nickel, lithium, aluminum and other elements from spent battery cathodes and are not limited by equilibrium constraints as compared to traditional solvent extraction processes.

Bhave, Ramesh R.↗

Sulfonamide and Sulfonamido-phenol Ligands for Extraction of f-Elements from Alkaline High-Level Waste

Alkaline High Level Waste (HLW) has been accumulated at Hanford and Savannah River Sites as a result of reprocessing for nuclear weapons production during the cold war. A large volume (∼100 MGal) has been accumulated in carbon steel tanks at Savannah River (SRS) and Hanford. The tank waste contains three separate phases generated when NaOH was added to previously acidic Purex raffinates: 1-2 Supernatant liquid, salt-cake, and sludge. The sludge consists mainly of insoluble hydroxides of transition metals while the supernate and salt-cake contain caustic-soluble materials, including salts of highly radioactive fission products Cs(I) and Sr(II). Current treatment of alkaline HLW in SRS includes: i) The Actinide Removal Process (ARP), which is based on sorption of {sup 90}Sr and Actinides (An) on monosodium titanate (MST), also known as 'alpha-strike' process, followed by ii) Caustic Side Solvent Extraction (CSSX),4 which is used for the extraction of {sup 137}Cs by modified calixarenes in a hydrocarbon diluent. Residual actinides in some tanks are removed after CSSX by an additional ARP process commonly referred to as 'alpha-finishing'. Despite the success of ARP for Sr and An removal, as it is a sorption process, it represents the kinetic bottleneck of integrated salt waste processing. Hence potential introduction of additional organic ligands for actinide extraction (in a modified CSSX process) could simplify the overall integrated process, making it more efficient and economical, with less titanate needed and shorter sorption time, as some of the actinide component would be removed during CSSX. In this study tri-sulfonamide and o-sulfonamido-phenol (mono-sulfonamide) ligands have been studied as extractants for Sm(III), which is being used as an Am(III) surrogate. Our prior studies in the group using a tri-sulfonamide (iPr-tsa-B) showed favorable extraction for Sm(III) nitrate salts from alkaline solutions. Mono-sulfonamides possess similar orientation of binding sites to pyrocatechols, which have been found to be good ligands for Am(III) binding and extraction from alkaline media. Tri-sulfonamide of the type iPr-tsa-B6 (1 mM in CH{sub 2}Cl{sub 2} solution) was studied for Ln{sup 3+} extraction using Sm(NO{sub 3}){sub 3}.6H{sub 2}0 (10 and 25 μM) in alkaline solution of NaOH (0.05, 0.1, 0.2, 0.3 mM) / 0.1 M NaNO{sub 3}. Stripping of the organic phase was done using 0.1 M HNO{sub 3} and quantification of Sm{sup 3+} was done using ICP-OES at 359.3 nm. The need to improve stability of the complex led to synthesis of compounds with N-donor site closer to the central benzene ring to facilitate cation-π interactions. Synthesis of tri-sulfonamide type A: a) Chloromethyl methyl ether, SnCl{sub 4}, CH{sub 2}Cl{sub 2}, 0 deg. C, N{sub 2}, 4 h, 57%; b) NaN{sub 3}, reflux in H{sub 2}O/acetone for 22 h, 80%; c) PPh{sub 3}, THF/H{sub 2}O, 22 h, 79%; d) p-toluene sulfonyl chloride, Et{sub 3}N, 1,2-DCE, 22 h. Extraction: Sm(NO{sub 3}){sub 3}.6H{sub 2}O (2 mM) in 5 ml of aqueous NaOH (pH 10.5 - 14) + 6 ml of CH{sub 2}Cl{sub 2} solution of msa (20 mole equiv.) were rotated on a wheel (60 rpm; 20 h). Stripping: 5 ml of 0.1 M HNO{sub 3} + CH{sub 2}Cl{sub 2} solution of msa (after extraction, centrifugation and filtration) was rotated on the wheel (60 rpm; 20 h). Sm{sup 3+} was quantified using UV-Visible spectrophotometry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of Local Structural Loads Computed by OpenFAST Against Measurements From the Focal Experimental Campaign: Preprint

This work presents the validation of the local structural load modeling capability in OpenFAST for floating substructures based on data from the FOCAL experimental campaign. Previously, OpenFAST could only represent the floating substructure as a rigid body, and though this approach can model the global response of the floater in most cases, it is not able to capture the structural loads within its individual members. Consideration of local substructure loads is important for some floating designs, as the pursuit of cost reduction often results in lighter and more flexible structures. To address this limitation, the HydroDyn (hydrodynamics) and SubDyn (substructure dynamics) modules of OpenFAST have been recently extended to account for the flexibility of floating substructures. To validate this new capability, we compare the results obtained by OpenFAST with data measured during the FOCAL experimental campaign, which analyzed a 1:70 scale performance-matched model of the IEA 15-MW reference turbine atop a modified University of Maine VolturnUS-S semisubmersible in a wave basin under the action of both wind and waves. For the purposes of the present work, the most important feature of the experiment is the presence of load cells at the root of each pontoon, and our objective is to assess how well those loads are reproduced by OpenFAST. To model the distributed hydrodynamic and hydrostatic loads along the floating substructure, we adopt a strip-theory approach based on the Morison equation, and we discuss the impact of different hydrodynamic modeling options (wave stretching, MacCamy-Fuchs correction, and second-order wave kinematics) on both motions and loads. For simplicity, we focus on wave-only conditions, both regular and irregular. The results demonstrate good overall agreement for the loads at the root of the pontoons for the waves analyzed in this work, especially given the assumptions and simplifications inherent to a simple strip-theory model.

floating offshore wind turbine↗

Performance Analysis of Phase 2 Tracker Upgrade PS Module Before and After Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5 up to 7.5$\times10^{34}$\,cm$^{-2}$s$^{-1}$. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000--4000\,fb$^{-1}$ of proton-proton collisions at a center-of-mass energy of 14\,TeV. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, particle momentum discrimination capabilities and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Analysis of Phase 2 Tracker Upgrade PS Module Before and After Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5 up to 7.5$\times10^{34}$\,cm$^{-2}$s$^{-1}$. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000--4000\,fb$^{-1}$ of proton-proton collisions at a center-of-mass energy of 14\,TeV. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, particle momentum discrimination capabilities and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A High-Precision, Fast, Robust, and Cost-Effective Muon Detector Concept for the FCC-ee

We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements. The drift tubes deliver two-dimensional position measurements perpendicular to the tubes with a resolution around 100~$\mu$m. Meanwhile, the scintillator strips, read out with the wavelength-shifting fibers and silicon photomultipliers, provide fast timing information with a precision of 200~ps or better and measure the third coordinate along the tubes with a resolution of about 1~mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction and Separation of Rare-Earth Elements from Coal Fly Ash and Leachate using a Recyclable Ionic Liquid

Coal fly ash (CFA) can be a promising source for recovering rare-earth elements (REEs), as it contains a broad range of REEs with average concentrations frequently exceeding those in traditional rare earth mines. Recent research from our group has demonstrated that REEs can be preferentially extracted from CFA solids using a recyclable ionic liquid (IL), betainium bis-(trifluoromethylsulfonyl)imide ([Hbet][Tf2N]). When CFA was heated with the mixture of IL and an aqueous solution above 65°C, most leached REEs partitioned into the IL phase and were separated from the bulk elements. Subsequent acid stripping of the REE-loaded IL removed the REEs and regenerated the IL for reuse in multiple extraction cycles. This IL-based REE-CFA recovery method has been applied to ten CFA samples derived from different coal sources, including ash recovered from disposal ponds. Analysis of 34 elements confirmed the process consistently achieved high REE recovery efficiency, with strong selectivity over bulk and trace elements across diverse CFA types. In addition to the IL-solid extraction, the performance of [Hbet][Tf2N] in extracting REEs from fly-ash leachates have been evaluated by four commonly used leaching reagents, including HCl, HNO3, H2SO4, and citrate. During the IL-leachate extraction, [Hbet][Tf2N] was mixed and heated with a Class C fly ash leachate generated from each leaching reagent, followed by an acid stripping. It was observed that the partitioning and recovery of REEs increased as the leachate pH increased from 3 to 11. Among the investigated leachates, HCl and citrate proved to be the most compatible with IL extraction, exhibiting a slightly higher REE recovery and a lower non-REE co-extraction compared to the IL-solid extraction. Sc, Y, Nd, Sm, Gd, Dy, and Yb consistently showed a high recovery rate from both CFA solids and leachates. Notably, Pr, Tb, and Ho, which were not previously leached from the CFA solids, were partially recovered from the leachates. Overall, our studies revealed the strong potential of [Hbet][Tf2N] for effectively recovering REEs from leachates, highlighting its applicability as a sustainable strategy for other aqueous REE feedstocks. Furthermore, a techno-economic analysis will be performed to quantify the economic viability of the IL-based REE recovery method and guide future process improvement.

42 ENGINEERING↗

Chemical Renal Denervation in the Rat

Introduction: The recent success of renal denervation in lowering blood pressure in drug-resistant hypertensive patients has stimulated interest in developing novel approaches to renal denervation including local drug/chemical delivery. The purpose of this study was to develop a rat model in which depletion of renal norepinephrine (NE) could be used to determine the efficacy of renal denervation after the delivery of a chemical to the periadventitial space of the renal artery. Methods: Renal denervation was performed on a single renal artery of 90 rats (n = 6 rats/group). The first study determined the time course of renal denervation after surgical stripping of a renal artery plus the topical application of phenol in alcohol. The second study determined the efficacy of periadventitial delivery of hypertonic saline, guanethidine, and salicylic acid. The final study determined the dose–response relationship for paclitaxel. In all studies, renal NE content was determined by liquid chromatography–mass spectrometry. Results: Renal NE was depleted 3 and 7 days after surgical denervation. Renal NE was also depleted by periadventitial delivery of all agents tested (hypertonic saline, salicylic acid, guanethidine, and paclitaxel). A dose response was observed after the application of 150 μL of 10{sup −5} M through 10{sup −2} M paclitaxel. Conclusion: We developed a rat model in which depletion of renal NE was used to determine the efficacy of renal denervation after perivascular renal artery drug/chemical delivery. We validated this model by demonstrating the efficacy of the neurotoxic agents hypertonic saline, salicylic acid, and guanethidine and increasing doses of paclitaxel.

60 APPLIED LIFE SCIENCES↗

A closure model for predicting crack growth under creep-fatigue loading

A strip-yield model was formulated here to simulate creep-fatigue crack growth and to quantify the influence of hold time on plasticity-induced crack closure during creep-fatigue crack growth. Creep-fatigue experiments have shown that longer creep hold times result in faster crack growth rates in subsequent fatigue cycles. This model advances the idea that a decrease of plasticity-induced crack closure is experienced by the crack during fatigue loading when a longer hold time is applied each creep-fatigue cycle. Consequently, the crack tip experiences an increase in the effective stress intensity factor range causing faster growth rate during the fatigue loading. The weight function method was used to compute stress intensity factors and surface displacements for cracks embedded in a material experiencing elastic, plastic and creep deformations at elevated temperatures. It is shown that the longer the hold time, the larger the creep deformation and crack opening displacements in the near crack-tip region. In turn, this leads to a decrease in the crack-tip opening stress/load and faster crack growth rates during the subsequent fatigue cycle. The model was used to perform simulations of creep-fatigue crack growth at elevated temperatures in a nickel-base superalloy and AISI 316 austenitic steel.

42 ENGINEERING↗

Electrochemical sulfate production from sulfide-containing wastewaters and integration with electrochemical nitrogen recovery

Electrochemical methods can help manage sulfide in wastewater, which poses environmental and health concerns due to its toxicity, malodor, and corrosiveness. In addition, sulfur could be recovered as fertilizer and commodity chemicals from sulfide-containing wastewaters. Wastewater characteristics vary widely among wastewaters; however, it remains unclear how these characteristics affect electrochemical sulfate production. Here, in this study, we evaluated how four characteristics of influent wastewaters (electrolyte pH, composition, sulfide concentration, and buffer strength) affect sulfide removal (sulfide removal rate, sulfide removal efficiency) and sulfate production metrics (sulfate production rate, sulfate production selectivity). We identified that electrolyte pH (3 × difference, i.e., 25.1 to 84.9 μM h –1 in average removal rate within the studied pH range) and sulfide concentration (16 × difference, i.e., 82.1 to 1347.2 μM h –1 in average removal rate) were the most influential factors for electrochemical sulfide removal. Sulfate production was most sensitive to buffer strength (6 × difference, i.e., 4.4 to 27.4 μM h –1 in average production rate) and insensitive to electrolyte composition. Together, these results provide recommendations for the design of wastewater treatment trains and the feasibility of applying electrochemical methods to varying sulfide-containing wastewaters. In addition, we investigated a simultaneous multi-nutrient (sulfur and nitrogen) process that leverages electrochemical stripping to further enhance the versatility and compatibility of electrochemical nutrient recovery.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualizing electrode assembly movement and lithiation heterogeneity in lithium-metal batteries using operando energy dispersive X-ray diffraction

There is renewed interest in Li-metal anodes in order to increase the energy density of battery cells. Here, we demonstrate an operando X-ray crystallography method to visualize lithiation gradients and electrode assembly movement during electrochemical cycling of a Li-metal cell containing a Ni-Mn-Co layered oxide cathode (NMC811). During charge, deposition of Li + ions from the cathode increases the Li foil thickness; during discharge, the thickness decreases as Li + ions are stripped off the foil. Additionally, the resulting periodic movement is observed through tracking of Bragg peaks from the ordered phases of the cathode and separator. In addition to this 3.6 μm/mAh displacement, continuous mossy Li build-up on the anode causes an irreversible drift of the assembly, which is similar to 11.3 μm/cycle. Furthermore, our data indicate significant lithiation gradients in the NMC811 cathode during the oxide relithiation, which is not observed during the delithiation.

25 ENERGY STORAGE↗

A new ATLAS muon CSC readout system with system on chip technology on ATCA platform

The ATLAS muon Cathode Strip Chamber (CSC) back-end readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run 2 luminosity. The readout design is based on the Reconfiguration Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the ATCA platform. The RCE design is based on the new System on Chip Xilinx Zynq series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources together with auxiliary memories to form a versatile DAQ building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the Zynq for G-link, S-link and TTC allowed the full system of 320 G-links from the 32 chambers to be processed by 6 COBs in one ATCA shelf through software waveform feature extraction to output 32 S-links. Furthermore, the full system was installed in Sept. 2014. We will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning towards LHC Run 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KALYPSO: Linear array detector for high-repetition rate and real-time beam diagnostics

Synchrotrons and modern FEL light sources operate with bunch repetition rates in the MHz range. The profile of the electron beam inside the accelerator can be characterized with indirect experimental techniques where linear array detectors are employed to measure the emitted synchrotron radiation or the spectrum of a near-IR laser. To improve the performance of modern beam diagnostics we have developed KALYPSO, a detector system operating with a continuous frame rate of up to 2.7 MHz. To facilitate the integration in different experiments, a modular architecture has been adopted. Different semiconductor micro-strip sensors can be connected to front-end ASICs to optimize the quantum efficiency at different photon energies, ranging from visible light up to near-IR. The front-end electronics are integrated within an heterogeneous DAQ consisting of FPGAs and GPUs, which allows scientists to implement real-time data processing algorithms. The current version of the detector is in operation at the KARA synchrotron light source and at the European XFEL. Finally, in this contribution we present the detector architecture, the performance results and the on-going technical developments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a large active area beam telescope based on the SiD microstrip sensor

A beam telescope as one of the most important and often requested test beam equipment provides particle tracking to test beam users. At the DESY II test beam facility, a new beam telescope called Lycorisbased on a microstrip sensor has been designed to address the user demands for momentum measurement in a 1 T solenoid magnet or large area tracking with limited space (3.5 cm between the potential user device and the magnet inner wall). Lycorisis designed to provide a high-precision resolution of at least ~10 µm along the bending direction, and a large active area of 10x10 cm 2 to cover at least 90% of the beam particles at energies of 1-6 GeV. The microstrip sensor was originally designed for the Silicon Detector (SiD) at the International Linear Collider (ILC), which adopted a hybrid-less design, i.e. a second metallization layer is used to route signals from strips to the bump-bonded ASIC, and from the ASIC to a wire-bond pad to the outside. This hybrid-less arrangement eliminates the need for a complex hybrid design, and its functioning is first-time tested in this project. The performance of the sensor modules was firstly tested in the lab then at the DESY II test beam facility in August/September 2018, and the results will be presented here. In addition, a summary will be given at the end with an overview of the ongoing test beam campaign of the Lycorisprototype in February 2019.

47 OTHER INSTRUMENTATION↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗