Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Rigorous constraints on three-nucleon forces in chiral effective field theory from fast and accurate calculations of few-body observables

We explore the constraints on the three-nucleon force (3NF) of chiral effective field theory (χ EFT) that are provided by bound-state observables in the A = 3 and A = 4 sectors. Our statistically rigorous analysis incorporates experimental error, computational method uncertainty, and the uncertainty due to truncation of the χ EFT expansion at next-to-next-to-leading order. A consistent solution for the 3 H binding energy, the 4 He binding energy and radius, and the 3 H β-decay rate can only be obtained if χ EFT truncation errors are included in the analysis. Here, the β-decay rate is the only one of these that yields a nondegenerate constraint on the 3NF low-energy constants, which makes it crucial for the parameter estimation. We use eigenvector continuation for fast and accurate emulation of no-core shell model calculations of the few-nucleon observables. This facilitates sampling of the posterior probability distribution, allowing us to also determine the distributions of the parameters that quantify the truncation error. We find a χ EFT expansion parameter of Q = 0.33 ± 0.06 for these observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupling relativistic viscous hydrodynamics to Boltzmann descriptions

Models of relativistic heavy-ion collisions typically involve both a hydrodynamic module to describe the high-density liquidlike phase and a Boltzmann module to simulate the low-density breakup phase, which is gaslike. Coupling the prescriptions is more complicated for viscous prescriptions if one wants to maintain continuity of the entire stress-energy tensor and currents. Derivations for the viscosity for a gas are reviewed, which then lead to expressions for changes in the phase-space occupation based on simple relaxation-time pictures of viscosity. These expressions are shown to consistently reproduce the nonequilibrium components of the stress-energy tensor. An algorithm for generating a Monte Carlo sampling of particles with which to initiate the Boltzmann calculations is also presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hydrodynamic simulations of relativistic heavy-ion collisions with different lattice quantum chromodynamics calculations of the equation of state

Hydrodynamic calculations of ultrarelativistic heavy-ion collisions are performed using the iebe-vishnu 2+1-dimensional code with fluctuating initial conditions and three different parametrizations of the lattice QCD equations of state: continuum extrapolations for stout and HISQ/tree actions, as well as the s95p-v1 parametrization based upon calculations using the p4 action. All parametrizations are matched to a hadron resonance gas equation of state at T = 155 MeV, at which point the calculations are continued using the urqmd hadronic cascade. Simulations of √s N N = 200 GeV Au+Au collisions in three centrality classes are used to quantify anisotropic flow developed in the hydrodynamic phase of the collision as well as particle spectra and pion Hanbury-Brown-Twiss (HBT) radii after hadronic rescattering, which are compared with experimental data. Experimental observables for the stout and HISQ/tree equations of state are observed to differ by less than a few percent for all observables, while the s95p-v1 equation of state generates spectra and flow coefficients which differ by ~10 – 20 %. Finally, calculations in which the HISQ/tree equation of state is sampled from the published error distribution are also observed to differ by less than a few percent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the B 0 s . Production Cross Section withB 0 s →J/ψΦ Decays in pp Collisions at √s=7 TeV

The B 0 s differential production cross section is measured as functions of the transverse momentum and rapidity in pp collisions at √s=7 TeV, using the B 0 s →J/ψΦ decay, and compared with predictions based on perturbative QCD calculations at next-to-leading order. The data sample, collected by the CMS experiment at the LHC, corresponds to an integrated luminosity of 40 pb⁻¹. The B 0 s is reconstructed from the decays J/ψ→μ⁺μ⁻ and Φ→K⁺K⁻. The integrated B 0 s cross section times B 0 s →J/ψΦ branching fraction in the range 8 B T <50 GeV/c and |yB|<2.4 is measured to be 6.9±0.6±0.6 nb, where the first uncertainty is statistical and the second is systematic.

Chatrchyan, S.↗

Nature of native atomic defects in ZrTe 5 and their impact on the low-energy electronic structure

Over the past decades, investigations of the anomalous low-energy electronic properties of ZrTe 5 have reached a wide array of conclusions. An open question is the growth method's impact on the stoichiometry of ZrTe 5 samples, especially given the very small density of states near its chemical potential. In this work, we report on high-resolution scanning tunneling microscopy and spectroscopy measurements performed on samples grown via different methods. Using density functional theory calculations, we identify the most prevalent types of atomic defects on the surface of ZrTe 5 , namely, Te vacancies and intercalated Zr atoms. Finally, we precisely quantify their density and outline their role as ionized defects in the anomalous resistivity of this material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative phase measurements of human cell nuclei using X-ray ptychography

The human cell nucleus serves as an important organelle holding the genetic blueprint for life. In this work, X-ray ptychography was applied to assess the masses of human cell nuclei using its unique phase shift information. Measurements were carried out at the I13-1 beamline at the Diamond Light Source that has extremely large transverse coherence properties. Furthermore, the ptychographic diffractive imaging approach allowed imaging of large structures that gave quantitative measurements of the phase shift in 2D projections. In this paper a modified ptychography algorithm that improves the quality of the reconstruction for weak scattering samples is presented. The application of this approach to calculate the mass of several human nuclei is also demonstrated.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient end-to-end simulation of time-dependent coherent X-ray scattering experiments

Physical optics simulations for beamlines and experiments allow users to test experiment feasibility and optimize beamline settings ahead of beam time in order to optimize valuable beam time at synchrotron light sources like NSLS-II. Further, such simulations also help to develop and test experimental data processing methods and software in advance. The Synchrotron Radiation Workshop ( SRW ) software package supports such complex simulations. We demonstrate how recent developments in SRW significantly improve the efficiency of physical optics simulations, such as end-to-end simulations of time-dependent X-ray photon correlation spectroscopy experiments with partially coherent undulator radiation (UR). The molecular dynamics simulation code LAMMPS was chosen to model the sample: a solution of silica nanoparticles in water at room temperature. Real-space distributions of nanoparticles produced by LAMMPS were imported into SRW and used to simulate scattering patterns of partially coherent hard X-ray UR from such a sample at the detector. The partially coherent UR illuminating the sample can be represented by a set of orthogonal coherent modes obtained by simulation of emission and propagation of this radiation through the coherent hard X-ray (CHX) scattering beamline followed by a coherent-mode decomposition. GPU acceleration is added for several key functions of SRW used in propagation from sample to detector, further improving the speed of the calculations. The accuracy of this simulation is benchmarked by comparison with experimental data.

36 MATERIALS SCIENCE↗

Signal-Compensation-Based Adaptive PID Control for Fused Magnesia Smelting Processes

For fused magnesia smelting processes, the proportional-integral-derivative (PID) controller is difficult to regulate the smelting currents within desired ranges due to unexpected variations of the dynamics caused by material feeding operations. To solve this problem, we first proposed its dynamic model composed of a linear model and an uncertain nonlinear dynamic system that describes the unknown time-varying dynamics of nonlinearity and strong couplings among controlled variables. Then, using the accurately calculated value of the uncertain part at the previous sampling time instant and the tracking error that reflects the influence of its change rate, we developed a feedforward and a one-step optimal control to obtain two signal compensators to eliminate the impact of frequent variations of the uncertainties. For the compensators, we proposed a weight selection method to minimize the sum of the squared tracking error with ensured closed-loop stability. Based on the abovementioned modeling and control structure, we finally developed a novel adaptive PID controller augmented with signal compensators to control the whole process. Industrial applications have shown that the proposed method can always keep the tracking error and the control input within their targeted ranges, leading to a significantly reduced energy consumption per ton and increased fused magnesia production.

Wang, Weizhou↗

Human radiation dosimetry of 6-[{sup 18}F]FDG predicted from preclinical studies

Purpose: The authors are developing 6-[{sup 18}F]fluoro-6-deoxy-D-glucose (6-[{sup 18}F]FDG) as an in vivo tracer of glucose transport. While 6-[{sup 18}F]FDG has the same radionuclide half-life as 2-[{sup 18}F]fluoro-2-deoxy-D-glucose (2-[{sup 18}F]FDG) which is ubiquitously used for PET imaging, 6-[{sup 18}F]FDG has special biologic properties and different biodistributions that make it preferable to 2-[{sup 18}F]FDG for assessing glucose transport. In preparation for 6-[{sup 18}F]FDG use in human PET scanning, the authors would like to determine the amount of 6-[{sup 18}F]FDG to inject while maintaining radiation doses in a safe range. Methods: Rats were injected with 6-[{sup 18}F]FDG, euthanized at specified times, and tissues were collected and assayed for activity content. For each tissue sample, the percent of injected dose per gram was calculated and extrapolated to that for humans in order to construct predicted time-courses. Residence times were calculated as areas under the curves and were used as inputs to OLINDA/EXM in order to calculate the radiation doses. Results: Unlike with 2-[{sup 18}F]FDG for which the urinary bladder wall receives the highest absorbed dose due to urinary excretion, with 6-[{sup 18}F]FDG there is little urinary excretion and osteogenic cells and the liver are predicted to receive the highest absorbed doses: 0.027 mGy/MBq (0.100 rad/mCi) and 0.018 mGy/MBq (0.066 rad/mCi), respectively. Also, the effective dose from 6-[{sup 18}F]FDG, i.e., 0.013 mSv/MBq (0.046 rem/mCi), is predicted to be approximately 30% lower than that from 2-[{sup 18}F]FDG. Conclusions: 6-[{sup 18}F]FDG will be safe for use in the PET scanning of humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-FG-BRA-01: 4D Monte Carlo Simulations for Verification of Dose Delivered to a Moving Anatomy

Purpose: To validate 4D Monte Carlo (MC) simulations of dose delivery by an Elekta Agility linear accelerator to a moving phantom. Methods: Monte Carlo simulations were performed using the 4DdefDOSXYZnrc/EGSnrc user code which samples a new geometry for each incident particle and calculates the dose in a continuously moving anatomy. A Quasar respiratory motion phantom with a lung insert containing a 3 cm diameter tumor was used for dose measurements on an Elekta Agility linac with the phantom in stationary and moving states. Dose to the center of tumor was measured using calibrated EBT3 film and the RADPOS 4D dosimetry system. A VMAT plan covering the tumor was created on the static CT scan of the phantom using Monaco V.5.10.02. A validated BEAMnrc model of our Elekta Agility linac was used for Monte Carlo simulations on stationary and moving anatomies. To compare the planned and delivered doses, linac log files recorded during measurements were used for the simulations. For 4D simulations, deformation vectors that modeled the rigid translation of the lung insert were generated as input to the 4DdefDOSXYZnrc code as well as the phantom motion trace recorded with RADPOS during the measurements. Results: Monte Carlo simulations and film measurements were found to agree within 2mm/2% for 97.7% of points in the film in the static phantom and 95.5% in the moving phantom. Dose values based on film and RADPOS measurements are within 2% of each other and within 2σ of experimental uncertainties with respect to simulations. Conclusion: Our 4D Monte Carlo simulation using the defDOSXYZnrc code accurately calculates dose delivered to a moving anatomy. Future work will focus on more investigation of VMAT delivery on a moving phantom to improve the agreement between simulation and measurements, as well as establishing the accuracy of our method in a deforming anatomy. This work was supported by the Ontario Consortium of Adaptive Interventions in Radiation Oncology (OCAIRO), funded by the Ontario Research Fund Research Excellence program.

60 APPLIED LIFE SCIENCES↗

Aethalometer™ Instrument Handbook

The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and a “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.

54 ENVIRONMENTAL SCIENCES↗

Measurements of Prompt Radiation-Induced Conductivity of Pyralux®

In this report, measurements of the prompt radiation-induced conductivity (RIC) in 3 mil samples of Pyralux® are presented as a function of dose rate, pulse width, and applied bias. The experiments were conducted with the Medusa linear accelerator (LINAC) located at the Little Mountain Test Facility (LMTF) near Ogden, UT. The nominal electron energy for the LINAC is 20 MeV. Prompt conduction current data were obtained for dose rates ranging from ~2 x 10 9 rad(Si)/s to ~1.1 x 10 11 rad(Si)/s and for nominal pulse widths of 50 ns and 500 ns. At a given dose rate, the applied bias across the samples was stepped between -1500 V and 1500 V. Calculated values of the prompt RIC varied between 1.39x10 -8 Ω -1 · m -1 and 2.67x10 -7 Ω -1 · m -1 and the prompt RIC coefficient varied between 1.25x10 -18 Ω -1 · m -1 /(rad/s) and 1.93x10 -17 Ω -1 · m -1 /(rad/s).

36 MATERIALS SCIENCE↗

A Method for Extrapolating CMM Data

This report provides a method for evaluating coordinate measuring machine (CMM) data and extrapolating the data to estimate the dimensions of a cylindrical component beyond the sampled measurements. The theoretical basis is provided, and a calculational method is presented. The report also provides detailed, formatted, printed, and plotted representations.

36 MATERIALS SCIENCE↗

Best Practices for Shielding Analyses of Activated Metals and Spent Resins from Reactor Operation

This report investigated best practices for performing shielding evaluations of Type B waste packages, as defined in 10 CFR Part 71 regulations on packaging and transportation of radioactive material, or packages for which the contents are not defined before loading and may include a broad range of nuclides, geometries, and non-fuel materials. The following non-fuel waste streams were analyzed: Activated metals from decommissioned commercial power reactors, including Type 304 stainless steel, reactor vessel steel, and Inconel, Control blades from boiling water reactors, Neutron-activated corrosion products on surfaces of activated metals, and Spent resins from power plant operations. Measured elemental compositions, including major constituents and impurities, for steel and Inconel samples from commercial power reactors were used in activation calculations to determine radionuclide inventories in activated metals. For a simplified cask model, 60 Co contribution to the total external package dose rate at 30 days after shutdown varied from approximately 60% to 95%, depending on the activated metal, initial cobalt impurity concentration in the metal, and the thickness of the overpack gamma shield. Its maximum contribution to the total external package dose rate of approximately 100% was reached within the time interval of 2 to 5 years after shutdown and was maintained for up to 45 to 60 years after shutdown, depending on material, initial cobalt impurity concentration, and shield thickness. Thereafter, the 60 Co contribution to external package dose rate decreased with increasing decay time. Cobalt-60 is primarily produced by neutron reactions with the cobalt impurity in steel and Inconel. Other important radionuclides in activated metals contributing to package external dose rate are radionuclides with relatively short decay times, including 51 Cr, 59 Fe, 58 Co, and 54 Mn. These radionuclides may be represented as an equivalent 60 Co activity/source because 60 Co gamma ray emissions are bounding in terms of source strength and energy to other important radionuclides identified in the analyzed activated metals. Approaches for modeling the neutron-activated corrosion products that may be attached to activated reactor components were analyzed in this report. It was demonstrated that a surface source is more conservative than a uniform volumetric source for the treatment of neutron-activated corrosion products with respect to external package dose rates. An analysis of the maximum radionuclide loadings reported on spent resins identified the radionuclides 137 Cs, 60 Co, 134 Cs, 65 Zn, and 58 Co as the primary contributors to external package dose rate. For a resin cooled for 3.08 years, the external package dose rate was entirely produced by the reported 137 Cs and 60 Co inventory. The neutron sources from actinides found on spent resins or activated metals produced negligible dose rates and may be ignored in dose rate analyses. Effects of idealized waste material, source geometry, and spatial material/source distributions on external package dose rates were determined based on dose rate results for a simplified cask model under normal conditions of transport. Type 304 stainless steel, zirconium, and aluminum with adjusted mass densities based on a maximum content weight were analyzed for material modeling effects on external package dose rate. These materials produced identical external package dose rates within the statistical uncertainties of the dose rate estimates. Among four different source geometry configurations with homogeneous material of different mass densities, uniform volumetric source distribution, and the same source strength, the geometry configuration with lowest mass density (i.e., minimum self-shielding effect among the four cases) was most conservative. Spatial source distributions that better represent localized peak 60 Co activity values were more conservative than a uniform volumetric source distribution, assuming the same weight and total source strength per package. The increase in external dose rate caused by localized source peaks can be as much as the ratio between source peak activity density to average activity density, depending on the location of the activated metal with peak activity density. Therefore, the shielding analysis may be simplified if localized peak activities and the average activity per package can be measured/determined and documented at the time of cask loading. For simplicity, external package dose rates may be determined based on average source activity and a uniform volumetric source distribution. The dose rate results from that calculation model multiplied by the ratio of peak activity density to average activity density will produce maximum dose rate values for conservative estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Activity Waste Glass Standards Preparation and Characterization for Calibration of Analytical Instruments

A matrix of seven low-activity waste (LAW) glasses was fabricated and characterized to be used by the Hanford Waste Treatment and Immobilization Plant (WTP) as analytical instrument calibration and matrix interference standards when measuring LAW glass compositions. The matrix of glasses was designed to represent the range of LAW glass compositions that will be generated by the WTP. Samples from each of the seven glasses were measured with electron probe microanalysis (EPMA), ion chromatography (IC), and bulk inductively coupled plasma mass spectroscopy (ICP-MS) to determine the variability and accuracy across batches and within individually poured glass bar samples. High relative percent differences and standard deviations were calculated for components with low concentrations due to instrument detection limits. IC and ICP-MS percent differences and standard deviations were higher at low component concentrations. Otherwise, variability in measured compositions from IC and ICP-MS was generally lower than measurements from EPMA, with the exclusion of Cl, F, Si, and B. Overall, the two methods proved comparable and complementary. From EPMA, IC, and ICP-MS data, volatile elements were underrepresented compared to batched compositions, which suggested loss of these elements during melting. EPMA data was statistically analyzed to evaluate homogeneity within single bars and whole compositions for each of the seven glasses. Most of the variability within glass compositions occurred at the bar-to-bar level; however, no clear systematic trends were observed. Based on these analyses, when using these glasses as reference material, it is recommended that the overall mean and variance of each composition be used for performing instrument calibrations and analytical corrections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NRC Multiphysics Analysis Capability Deployment (FY2021 - Part 2)

This report details the progress and activities of Idaho National Laboratory (INL) on the Nuclear Regulatory Commission (NRC) project “Development and Modeling Support for Advanced Non-Light Water Reactors.” Task 4b was completed for this report. INL developed a sample problem showing how to use Serpent 2 to calculate macroscopic cross sections for use in Griffin for a typical sodium fast reactor Unprotected Loss of Flow (ULOF) transient. The complicating factor is the relatively large axial gradient of the coolant (and hence fuel) temperature and its evolution during the transient. A 3D Griffin model of the Advanced Burner Test Reactor (ABTR) is coupled to the System Analysis Module (SAM) to perform the ULOF transient. The model includes various explicit feedback mechanisms for fast reactors, including Doppler, radial expansion from the displacement of the support plate, and axial expansion from the displacement of the fuel pins. The results for the ULOF transient are consistent with published values. We observed small effects in the transient results that arise from the superhomogenization equivalence correction of uniform and nonuniform temperature data sets, but they diminish as more dominant reactivity mechanisms are added to the model. Potential improvements to the neutronics model include: adding the differential control rod and sodium feedback mechanisms, implementing cross section re-homogenization based on the partial volume of the various materials, and enhancing the kinetics parameters. Furthermore, the fluids model only includes four subchannels to represent the entire active core due to performance limitations in SAM when attempting to model one subchannel per assembly.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Finite-Geometry Corrections for Neutron Scattering Cross Section Measurements

In this report, we describe the corrections necessary for neutron scattering cross section measurements in experiments which use finite-geometry scattering samples. A new Geant4 based framework was developed to calculate these corrections which has been benchmarked against a well-measured test case. This framework also calculates the outgoing neutron energy dependence of the correction factors, which is crucial when resolving individual final states in the scatterer is not possible.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimating Large Global Significances with a New Monte Carlo Extrapolation Method

In particle physics, it is needed to evaluate the possibility that excesses of events in mass spectra are due to statistical fluctuations as quantified by the standards of local and global significances. Without prior knowledge of a particle’s mass, it is especially critical to estimate its global significance. The usual approach is to count the number of times a significance limit is exceeded in a collection of simulated Monte Carlo (MC) “toy experiments”. To demonstrate this conventional method for global significance, we performed simulation studies according to a recent Compact Muon Solenoid (CMS) result to show its effectiveness. However, this counting method is not practical for computing large global significances. To address this problem, we developed a new “extrapolation” method to evaluate the global significance. We compared the global significance estimated by our new method with that of the conventional approach, and verified its feasibility and effectiveness. This method is also applicable for cases where only small toy MC samples are available. In this approach, the significance is calculated based on p-values, assuming symmetrical Gaussian distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗