Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

East River Surface and Pore Water FTICR-MS Data Associated with “Implications of sample treatment on characterization of the riverine environmental metabolome”

Surface and pore water samples were collected from distributed locations around Meander A in East River (Crested Butte, CO, USA) during the summer of 2018. This dataset consists of the characterization of dissolved organic matter using 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS; in .xml format) analyzed through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory) using two different sample pre-treatment methods (solid phase extraction, no solid phase extraction) and two electrospray ionization methods (ESI-positive, ESI-negative) to identify the impacts of these choices on the final dataset. This study aimed to understand how the different sample processing methods influence the resulting FTICR-MS dataset. Any published work that utilizes data presented in this dataset should cite the dataset using the DOI number. If using the dataset, please acknowledge the U.S. Department of Energy (DOE) Office of Science (BER) Subsurface Biogeochemical Research (SBR) program, the Environmental Molecular Sciences Laboratory (EMSL), and Worldwide Hydrobiogeochemical Observation Network for Dynamic River Systems (WHONDRS). The publication DOI will be added to this abstract when available.

54 ENVIRONMENTAL SCIENCES↗

Loamy sand soil approaches organic carbon saturation after 37 years of conservation tillage

Conservation tillage is reported to increase soil organic carbon (SOC) and total nitrogen (TN) contents, but long-term (>30 yr) field results quantifying the responses in Coastal Plain Ultisols are sparse. The distribution, accumulation, and topsoil storage of SOC and TN after 37 yr of crop production using conventional (CvT) or conservation tillage (CnT) on a Norfolk loamy sand (fine-loamy, kaolinitic, thermic, Typic Kandiudults) were quantified. Soil samples were collected annually from the 0-5-, 5-10-, and 10-15-cm depth increments beneath corn (Zea mays L.), soybean [Glycine max (L.) Merr.], and cotton (Gossypium hirsutum L.) crops. Overall, SOC and TN accumulation in the 0-5-cm depth were highest for Norfolk soil under CnT. Focusing on total long-term changes for the 0-15-cm sampling depth beneath various corn crops shows that CnT and CvT sequestered 24.7 and 21.4 Mg C ha -1 , respectively. Between 1978 and 2016, there was a highly significant (P < .0001) exponential increase in SOC within the top 5-cm soil depth. However, the exponential curves began to plateau suggesting the Norfolk topsoil was approaching its organic carbon (OC) storage capacity. These field measurements strongly indicate that additional topsoil SOC increases with current tillage and crop management practices are limited.

54 ENVIRONMENTAL SCIENCES↗

Beam Damage of HS (CH2)15 COOH Terminated Self Assembled Monolayer (SAM) as Observed by X-Ray Photoelectron Spectroscopy

XPS spectra of HS(CH{sub 2}){sub 15} COOH terminated a self assembled monolayer (SAM)sample was collected over a period of 242 minutes to determine specimen damage during long exposures to monochromatic Al Ka x-rays. For this COOH terminated SAM we measured the loss of oxygen as a function of time by rastering a focused 100 W, 100 um diameter x-ray beam over a 1.4 mm x 0.2 mm area of the sample.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Compadre Toolkit

The Compadre Toolkit solves a minimization problem, that once solved allows a user to reconstruct a function from sample data collected from a cloud of data sites. The solution to this minimization can also be used to assemble a linear system that can be solved numerically using some other software. The minimization problem the toolkit solves is to find the optimal finite polynomial in a user specified finite dimensional space with regards to minimizing an objective function which measures a linear sampling functional applied to the polynomial, compared to the same sampling functional applied to the source function, weighted by a positive kernel that has compact support.

SciDAC↗

Speed and Memory Improvements to MCNP6 Delayed-Gamma Line Treatment

The delayed-gamma (DG) line-emission (line) sampling was first introduced into MCNPX in 2005. At the time, storage demands for problems with large numbers of DG lines was a major concern. In order to accommodate large amounts of line data while keeping the memory footprint of such a problem from exceeding memory limits, complicated logic was included to sift through various storage options. In mid-2015 concerns arose over the adequacy of the MCNP6 DG source option (inherited from MCNPX) with line sampling for modeling high-fidelity problems. One indication that there was a problem came when studying the MCNP6 produced DG spectra of U-238 and its progeny using high-fidelity spectroscopic tallies when compared to DG line amplitudes directly from ENDF/B-VII.1 emission data. Despite producing a correct integral number of gammas, the comparison to ENDF data showed a broadening in the energy lines and a reduction in the amplitude of more prominent lines. It was later found that the cause of this broadening was one of the memory-saving techniques used to store DG line data when problems required many DG lines. Specifically, the DG lines were integrated into fine energy bins for sampling. When a DG line was to be sampled, a random number would be used to choose which energy bin to sample based on emission probability. Once chosen, a second random number was used to perform nearest-line sampling in that bin. The integration of lines led to an oversampling of low-probability lines, especially when in close proximity to high-probability lines. This treatment also caused a similar issue with the time-dependent behavior of DG line emission which occurred when low-probability lines were sampled near high probability lines with the former decay constant being used. The effect on time-dependent gamma production was demonstrated in analytic benchmarks performed by Weldon et al.. To address these issues a new gamma line storage and sampling treatment was introduced in 2015. This new treatment, stores gamma emission data in a line-by-line CDF which is sampled directly, thereby resolving both the line-broadening issue, and the time-dependence issue as was demonstrated by Tutt el al.. In addition, the new DG sampling treatment was written to use dynamically dimensioned storage arrays as opposed to large fixed-dimensioned arrays, as in the former treatment, and also makes more efficient use of line data that is stored by reducing or eliminating repeated data. As a result, storage arrays are generated only for DG data relevant to the problem being executed. The result should be a reduction in both memory requirements and runtime. However, these reductions could not be realized until the logic for the old treatment could be removed. This paper provides an update on recent work which has focused on the removal of the old DG sampling logic and attempts to quantify the memory reduction and speed up of selected problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrafine Particulate Ferrous Iron and Anthracene Associations with Mitochondrial Dysfunction

The ultrafine size fraction of ambient particles (ultrafine particles, UFP, diameter < 100 nm) has been identified as being far more potent in their adverse health effects than their larger counterparts, yet, the detailed mechanisms for why UFP display such distinctive toxicity are not well understood. In the present study, ambient UFP were exposed to mitochondria while monitoring electron transport chain (ETC) activity as a model system for biochemical toxicity. UFP samples were collected in rural (Ellensburg, WA) and urban environments (Seattle, WA) and chemically characterized for total trace metals, ferrous (Fe(II)) and easily reducible ferric (Fe(III)) iron, polycyclic aromatic hydrocarbons, and surface constituents with X-ray photoelectron spectroscopy (XPS). Low doses of UFP (8 µg mL-1) caused a decrease in mitochondrial ETC function compared to controls in 94% of the samples after The 20 min of exposure. Significant correlations exist between initial %ETC inhibition (0-10 min) and Fe(II) (R=0.55, P=0.03, N=15), anthracene (R=0.74, P<0.01, N=13), and %C-O surface bonds (R=0.56, P=0.03, N=15), whereby anthracene and %C-O correlate as well (R=0.58, P=0.03, N=14). No significant associations were identified with total Fe and other trace metals. Results from this study indicate that the redox active fraction of Fe as well as the abundance of anthracene-related, C-O containing, surface structures may contribute to the initial detrimental behavior of UFP, thus supporting the idea that the Fe(II)/Fe(III) and certain efficient hydroquinone/quinone redox pairs may play an important role likely due to their potential to produce reactive oxygen species (ROS).

59 BASIC BIOLOGICAL SCIENCES↗

National Emission Standards for Hazardous Air Pollutants – Radionuclide Emissions Calendar Year 2020

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and the North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. Radionuclides in air from NNSS activities have been monitored since the initiation of atmospheric testing. After 1962, testing was limited to underground detonations, which greatly reduced radiation exposure to the public. Since the end of nuclear testing in 1992, radiation monitoring has focused on detecting airborne radionuclides from historically contaminated soils because this sources dominates the potential offsite dose. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of manmade radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP), specifically the National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities (40 CFR 61, Subpart H, 2020) limits the release of radioactivity from a DOE facility to that which would cause 10 millirem per year (mrem/y) effective dose equivalent (EDE) to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as Japan’s Fukushima nuclear power plant, which was damaged in 2011. NNSA/NFO demonstrates compliance with the NESHAP limit by reporting environmental measurements of radionuclide air concentrations at critical receptor locations on the NNSS. This alternative was proposed and formerly submitted to the U.S. Environmental Protection Agency (EPA) in 2001 (EPA 2001a) and has been the method used to demonstrate compliance with the 40 CFR 61.92 dose standard since 2005. Six locations on the NNSS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are closer to radionuclide releases than where the public resides so they act as protective substitutes for public receptor locations. Compliance is demonstrated if the measured annual average concentration is less than the NESHAP Concentration Level (CL) for Environmental Compliance listed in Table 2 of 40 CFR 61, Appendix E. For multiple radionuclides, compliance is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. The EPAapproved air transport model, called the Clean Air Package 1988 (CAP88-PC) is also used to calculate the effective dose equivalent to the maximally exposed individual from NNSS air emissions. CAP88-PC was also used to calculate the population dose, or the collective EDE (expressed as person-rem [roentgen equivalent man] per year [person-rem/y]) for all individuals combined who reside within 80 kilometers (km) of NNSS emission sources. In 2020, the potential dose from radiological emissions to air from both current and past NNSS activities was well below the 10 mrem/y dose limit. This is demonstrated by both the air sampling data collected at critical receptor air monitoring stations and CAP88-PC modeling. The average concentrations of radioactivity at air critical receptor stations ranged from 0.2% to a maximum of 4.2% of the allowed NESHAP limit. CAP88-PC modeling of all 2020 NNSS radionuclide emissions showed the maximally exposed individual to be in Amargosa Valley and this individual received a potential dose of 0.063 mrem/y. The collective dose was calculated to be 0.29 person-rem/year for the 521,300 people who lived within 80 km of NNSS emission sources.

99 GENERAL AND MISCELLANEOUS↗

Old Woman Creek Wetland Sediment and Electrochemical Sensor Microbial Community, 2023

We are developing a technique to monitor microbiological activities referred to as zero resistance ammetry, which entails the deployment of graphite electrodes in sediments. Measurement of current between electrodes of contrasting redox regimes and/or predominant terminal electron accepting processes can be used as an indicator of the extents of microbiological activity. We deployed an electrode array at depths of 2 mm, 4 mm, 76 mm, 78 mm, 152 mm, 154 mm, 227 mm, and 229 mm below the wetland sediment water interface in the Old Woman Creek National Estuarine Research Center, Huron, OH, USA (Lat. = 41.380833, Long. = -82.508889). A core was collected from adjacent sediment and subsamples were collected from depth intervals of 0 – 25 mm, 25 – 127 mm, 127 – 128 mm, and below 178 mm. To determine if the microbial communities attached to the electrodes were reflective of the adjacent sediment-associated microbial community, we conducted a 16S rRNA gene-based (V4 region) survey of these respective materials. This data package contains the results of these surveys, including metadata on the depths from which samples were collected (samples.csv), DNA extraction and sequencing information (OWC_DEPTH_AMPLICON_SEQUENCING_METADATA), sequence processing information (OWC_DEPTH_BIOINFORMATIC_METADATA.csv), an operational taxonomic unit (OTU) table (OWC_DEPTH_97OTUS_TABLE.csv), and nucleotide sequences of OTUs (OWC_DEPTH_97OTUS_SEQS.fasta). All files can be opened using a text-editing application. The fasta file is compatible with bioinformatics applications.

54 ENVIRONMENTAL SCIENCES↗

Use of XRF to characterize pre-Hanford orchards in the 100-OL-1 operable unit - 15717

Prior to 1943, Hanford site included several small towns with approximately 5,000 acres of orchards; at the time lead arsenate (PbHAsO{sub 4}) was the most commonly used pesticide. High concentration of lead and arsenic have been recorded where trees and stumps are still visible. Pre-Hanford orchards have been designated as 100-OL-1 Operable Unit. An Optimization study evaluated optimal counting time and position of the XRF from soils collected at the site. A Pilot Study included the evaluation of a field portable x-ray fluorescence (XRF) analyzer determining if performance results meet quality assurance criteria for cleanup. XRF has only previously been used as a screening tool. Four Decision Units (DUs) are to be analyzed: Ol-14. OL-32. OL-IU6-4 and OL-FR2-1. The DUs vary in size and have had distinct historic activities; such as 46.4 acres OL-14 having a military camp in the 1950's unlike OL-FR2-1 having been disturbed as it is near the F area reactor. Together the DUs provide an adequate representation of the Operable Unit. Screening criteria for lead (250 mg/kg) and arsenic (20 mg/kg). Six samples were collected ranging above, at, and below the screening criteria of 250 mg/kg for Pb and 20 mg/kg for As at the Decision Units OL-14 and OL-IU6-4, and labeled respectively. Samples were hand sieved, homogenized and placed in sample cups. Three replicates were prepared for each sample. Each sample cup was analyzed 3 times for 30 sec. A Standard Reference Material (SRM) was analyzed after every 20 readings. Three samples were selected for 15, 30, 45, 60, 90, 120, 150 and 180 second fixed and variable analysis. Two transects at OL-14, and one at OL-IU6-4 were created by selecting locations 90. around ground zero at distances of 0.5, 1, 2, 4, 8 and 12 feet (16 ft for OL-14). Locations were scanned in triplicate for 60 seconds each. 4 Decision Units spanning roughly 370 acres were chosen to represent 100-OL-1 Operable Unit. 40 locations within each DU were selected using Visual Sample Plan (VSP) with a random start and systematic grid pattern. Each location would be analyzed with 3 replicates and a 60 second count time. The Standard Reference Material (SRM) and blank are analyzed after every 20 counts to ensure accuracy. Data is extracted from XRF to be implemented in GIS for visual representation of site with 1943 and 2013 aerial imagery. Discussion/Conclusion: - XRF provided a good indication of precision and accuracy relative to ICP with a linear correlation R{sup 2} value higher than anticipated at .9735; - MDL proved the detection limit is significantly lower than the screening criteria; - When comparing results from the first 40 locations of OL-14 to the total 80 locations of OL-14, the same variability was seen; - We expect high concentrations of Pb and As to be where past orchards are present though this does not occur as all sites. Significance: - XRF is competent for decision making as values fall within ±20% ICP data; - The highest concentrations are not where expected, which may be an issue for sites outside of Hanford that have had more development; - The size of the DU does not affect the number of samples measured. Future Work: - Verification and validation of the XRF Data (QA/QC); - Revise conceptual site model; - Statistical evaluations to investigate: Estimation of variability in surface soils, appropriate size for DU, and sample size per DU; - Coordinating sample results through CORE; - Displaying sample results in PHOENIX (GIS tool)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of in vivo quantification accuracy of the Ingenuity-TF PET/MR

Purpose: The quantitative accuracy of standardized uptake values (SUVs) and tracer kinetic uptake parameters in patient investigations strongly depends on accurate determination of regional activity concentrations in positron emission tomography (PET) data. This determination rests on the assumption that the given scanner calibration is valid in vivo. In a previous study, we introduced a method to test this assumption. This method allows to identify discrepancies in quantitative accuracy in vivo by comparison of activity concentrations of urine samples measured in a well-counter with activity concentrations extracted from PET images of the bladder. In the present study, we have applied this method to the Philips Ingenuity-TF PET/MR since at the present stage, absolute quantitative accuracy of combined PET/MR systems is still under investigation. Methods: Twenty one clinical whole-body F18-FDG scans were included in this study. The bladder region was imaged as the last bed position and urine samples were collected afterward. PET images were reconstructed including MR-based attenuation correction with and without truncation compensation and 3D regions-of-interest (ROIs) of the bladder were delineated by three observers. To exclude partial volume effects, ROIs were concentrically shrunk by 8–10 mm. Then, activity concentrations were determined in the PET images for the bladder and for the urine by measuring the samples in a calibrated well-counter. In addition, linearity measurements of SUV vs singles rate and measurements of the stability of the coincidence rate of “true” events of the PET/MR system were performed over a period of 4 months. Results: The measured in vivo activity concentrations were significantly lower in PET/MR than in the well-counter with a ratio of the former to the latter of 0.756 ± 0.060 (mean ± std. dev.), a range of 0.604–0.858, and a P value of 3.9 ⋅ 10{sup −14}. While the stability measurements of the coincidence rate of “true” events showed no relevant deviation over time, the linearity scans revealed a systematic error of 8%–11% (avg. 9%) for the range of singles rates present in the bladder scans. After correcting for this systematic bias caused by shortcomings of the manufacturers calibration procedure, the PET to well-counter ratio increased to 0.832 ± 0.064 (0.668 –0.941), P = 1.1 ⋅ 10{sup −10}. After compensating for truncation of the upper extremities in the MR-based attenuation maps, the ratio further improved to 0.871 ± 0.069 (0.693–0.992), P = 3.9 ⋅ 10{sup −8}. Conclusions: Our results show that the Philips PET/MR underestimates activity concentrations in the bladder by 17%, which is 7 percentage points (pp.) larger than in the previously investigated PET and PET/CT systems. We attribute this increased underestimation to remaining limitations of the MR-based attenuation correction. Our results suggest that only a 2 pp. larger underestimation of activity concentrations compared to PET/CT can be observed if compensation of attenuation truncation of the upper extremities is applied. Thus, quantification accuracy of the Philips Ingenuity-TF PET/MR can be considered acceptable for clinical purposes given the ±10% error margin in the EANM guidelines. The comparison of PET images from the bladder region with urine samples has proven a useful method. It might be interesting for evaluation and comparison of the in vivo quantitative accuracy of PET, PET/CT, and especially PET/MR systems from different manufacturers or in multicenter trials.

60 APPLIED LIFE SCIENCES↗

Zinc speciation and desorption kinetics in a mining waste impacted tropical soil amended with phosphate

Mining is an important component of the Brazilian economy. However, it may also contribute to environmental problems such as the pollution of soils with zinc and other potentially toxic metals. Our objective was to evaluate changes in the chemical speciation and mobility of Zn in a soil amended with phosphate. Soil samples were collected from a deactivated mining area in the state of Minas Gerais, Brazil, and amended with NH 4 H 2 PO 4 saturated with deionized water to 70 % of maximum water retention and incubated at 25 ± 2 °C in open containers for 60 days. The soil was chemically and mineralogically characterized, and sequential extraction, desorption kinetics, and speciation were carried out using synchrotron bulk-sample and micro–X-ray Absorption Near-Edge Structure (XANES/μ-XANES) spectroscopy at the Zn K-edge, and X-ray fluorescence microprobe analysis (μ-XRF). The combination of μ-XRF and μ-XANES techniques made it possible to identify Zn hotspots in the main species formed after phosphate remediation. The best fit combination for bulk XANES and μ-XANES was observed in Zn-montmorillonite, Zn-kerolite, Zn-ferrihydrite, and gahnite. In the course of phosphate treatment, gahnite, Zn layered double hydroxides (Zn-LDH), Zn3(PO4), and ZnO were identified by bulk XANES, while Zn-ferrihydrite, Zn-montmorillonite, and scholzite were identified by μ-XANES. Zinc in the phosphate-amended soil had the strongest partial correlations (r' > 0.05) with Ni, Co, Fe, Cr, Mn, Si, P, Cd, Pb, and Cd, while the unamended soil showed the strongest correlation with Cu, Pb, Fe, and Si. The application of NH 4 H 2 PO 4 altered Zn speciation and favored an increase in Zn desorption. Here, the most available Zn contents after phosphate amendment were correlated with the release of exchangeable Zn fractions, associated with carbonate and organic matter.

54 ENVIRONMENTAL SCIENCES↗

Levoglucosan data from five coastal streams impacted by the 2020 CZU Lightning Complex Fires, California, United States

This dataset includes levoglucosan data for five coastal California (United States) streams impacted by the 2020 CZU Lightning Complex Fires which burned from August 16th through September 22nd. Levoglucosan is a highly soluble and biolabile fraction of pyrogenic carbon. The five watersheds (San Lorenzo River, Pescadero Creek, Majors Creek, Laguna Creek, and Scott Creek) were impacted by the fires with watersheds experiencing a range of burn severity and extents. Grab samples were collected from each stream between October 2020 and May 2021, targeting both baseflow and event flow hydrologic conditions. Additional biogeochemistry data (i.e., organic and black carbon concentrations) can be found in a separate data package (https://doi.org/10.4211/hs.421c0226bb38460c8393d67fe0c4f802). This data package consists of one main data folder that contains (1) readme; (2) file-level metadata; (3) data dictionary; (4) field metadata with international generic sample numbers (IGSN); (5) methods codes; and (6) levoglucosan data. All files are .csv or .pdf.

2020 CZU Lightning Complex Fires↗

Fe-oxide grain coatings support bacterial Fe-reducing metabolisms in 1.7 - 2.0 km-deep subsurface quartz arenite sandstone reservoirs of the Illinois Basin (USA)

The Cambrian-age Mt. Simon Sandstone, deeply buried within the Illinois Basin of the midcontinent of North America, contains quartz sand grains ubiquitously encrusted with iron-oxide cements and dissolved ferrous iron in pore-water. Although microbial iron reduction has previously been documented in the deep terrestrial subsurface, the potential for diagenetic mineral cementation to drive microbial activity has not been well studied. In this study, two subsurface formation water samples were collected at 1.72 and 2.02 km, respectively, from the Mt. Simon Sandstone in Decatur, Illinois. Low-diversity microbial communities were detected from both horizons and were dominated by Halanaerobiales of Phylum Firmicutes. Iron-reducing enrichment cultures fed with ferric citrate were successfully established using the formation water. Phylogenetic classification identified the enriched species to be related to Vulcanibacillus from the 1.72 km depth sample, while Orenia dominated the communities at 2.02 km of burial depth. Species-specific quantitative analyses of the enriched organisms in the microbial communities suggest that they are indigenous to the Mt. Simon Sandstone. Optimal iron reduction by the 1.72 km enrichment culture occurred at a temperature of 40°C (range 20–60°C) and a salinity of 25 parts per thousand (range 25–75 ppt). This culture also mediated fermentation and nitrate reduction. In contrast, the 2.02 km enrichment culture exclusively utilized hydrogen and pyruvate as the electron donors for iron reduction, tolerated a wider range of salinities (25–200 ppt), and exhibited only minimal nitrate- and sulfate-reduction. In addition, the 2.02 km depth community actively reduces the more crystalline ferric iron minerals goethite and hematite. The results suggest evolutionary adaptation of the autochthonous microbial communities to the Mt. Simon Sandstone and carries potentially important implications for future utilization of this reservoir for CO2 injection.

59 BASIC BIOLOGICAL SCIENCES↗

Arsenic Sequestration By Sorption Processes in High-Iron Sediments

High-iron sediments in North Haiwee Reservoir (Olancha, CA), resulting from water treatment for removal of elevated dissolved arsenic in the Los Angeles Aqueduct system, were studied to examine arsenic partitioning between solid phases and porewaters undergoing shallow burial. To reduce arsenic in drinking water supplies, ferric chloride and a cationic polymer coagulant are added to the aqueduct upstream of Haiwee Reservoir, forming an iron-rich floc that scavenges arsenic from the water. Analysis by synchrotron X-ray absorption spectroscopy (XAS) showed that the aqueduct precipitate is an amorphous hydrous ferric oxide (HFO) similar to ferrihydrite, and that arsenic is associated with the floc as adsorbed and/or coprecipitated As(V). Arsenic-rich floc and sediments are deposited along the inlet channel as aqueduct waters enter the reservoir. Sediment core samples were collected in two consecutive years from the edge of the reservoir along the inlet channel using 30- or 90-cm push cores. Cores were analyzed for total and extractable arsenic and iron concentrations. Arsenic and iron speciation and mineralogy in sediments were examined at selected depths by synchrotron XAS and X-ray diffraction (XRD). Sediment-porewater measurements were made adjacent to the core sample sites using polyacrylamide gel probe samplers. Results showed that sediment As(V) is reduced to As(III) in all cores at or near the sediment-water interface (0--4 cm), and only As(III) was observed in deeper sediments. Analyses of EXAFS spectra indicated that arsenic is present in the sediments mostly as a bidentate-binuclear, inner-sphere sorption complex with local atomic geometries similar to those found in laboratory studies. Below about 10 cm depth, XAS indicated that the HFO floc had been reduced to a mixed Fe(II, III) solid with a local structure similar to that of synthetic green rust (GR) but with a slightly contracted average interatomic Fe-Fe distance in the hydroxide layer. There was no evidence from XRD for the formation of a crystalline GR phase. The release of dissolved iron (presumably Fe{sup 2+}) and arsenic to solution, as monitored by in situ gel probes, was variable but, in general, occurred at greater depths than arsenic reduction in the sediments by spectroscopic observations and appears to be near or below the depth at which sediment GR was identified. These data point to reductive dissolution of the sorbent iron phase as the primary mechanism of release of sorbed arsenic to solution.

43 PARTICLE ACCELERATORS↗

Generation and distribution of PAHs in the process of medical waste incineration

Highlights: ► PAHs generation and distribution features of medical waste incineration are studied. ► More PAHs were found in fly ash than that in bottom ash. ► The highest proportion of PAHs consisted of the seven most carcinogenic ones. ► Increase of free oxygen molecule and burning temperature promote PAHs degradation. ► There is a moderate positive correlation between total PCDD/Fs and total PAHs. - Abstract: After the deadly earthquake on May 12, 2008 in Wenchuan county of China, several different incineration approaches were used for medical waste disposal. This paper investigates the generation properties of polycyclic aromatic hydrocarbons (PAHs) during the incineration. Samples were collected from the bottom ash in an open burning slash site, surface soil at the open burning site, bottom ash from a simple incinerator, bottom ash generated from the municipal solid waste (MSW) incinerator used for medical waste disposal, and bottom ash and fly ash from an incinerator exclusively used for medical waste. The species of PAHs were analyzed, and the toxicity equivalency quantities (TEQs) of samples calculated. Analysis results indicate that the content of total PAHs in fly ash was 1.8 × 10{sup 3} times higher than that in bottom ash, and that the strongly carcinogenic PAHs with four or more rings accumulated sensitively in fly ash. The test results of samples gathered from open burning site demonstrate that Acenaphthylene (ACY), Acenaphthene (ACE), Fluorene (FLU), Phenanthrene (PHE), Anthracene (ANT) and other PAHs were inclined to migrate into surrounding environment along air and surface watershed corridors, while 4- to 6-ring PAHs accumulated more likely in soil. Being consistent with other studies, it has also been confirmed that increases in both free oxygen molecules and combustion temperatures could promote the decomposition of polycyclic PAHs. In addition, without the influence of combustion conditions, there is a positive correlation between total PCDD/Fs and total PAHs, although no such relationship has been found for TEQ.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 12H residuals sample analysis report

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 12H final characterization samples to determine the residual tank inventory prior to grouting. Eleven Tank 12H floor and mound residual material samples and three cooling coil scrape samples were collected and delivered to SRNL between May and August of 2014.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identifying Urinary and Serum Exosome Biomarkers for Radiation Exposure Using a Data Dependent Acquisition and SWATH-MS Combined Workflow

Purpose: Early and accurate assessment of radiation injury by radiation-responsive biomarkers is critical for triage and early intervention. Biofluids such as urine and serum are convenient for such analysis. Recent research has also suggested that exosomes are a reliable source of biomarkers in disease progression. In the present study, we analyzed total urine proteome and exosomes isolated from urine or serum for potential biomarkers of acute and persistent radiation injury in mice exposed to lethal whole body irradiation (WBI). Methods and Materials: For feasibility studies, the mice were irradiated at 10.4 Gy WBI, and urine and serum samples were collected 24 and 72 hours after irradiation. Exosomes were isolated and analyzed using liquid chromatography mass spectrometry/mass spectrometry-based workflow for radiation exposure signatures. A data dependent acquisition and SWATH-MS combined workflow approach was used to identify significantly exosome biomarkers indicative of acute or persistent radiation-induced responses. For the validation studies, mice were exposed to 3, 6, 8, or 10 Gy WBI, and samples were analyzed for comparison. Results: A comparison between total urine proteomics and urine exosome proteomics demonstrated that exosome proteomic analysis was superior in identifying radiation signatures. Feasibility studies identified 23 biomarkers from urine and 24 biomarkers from serum exosomes after WBI. Urinary exosome signatures identified different physiological parameters than the ones obtained in serum exosomes. Exosome signatures from urine indicated injury to the liver, gastrointestinal, and genitourinary tracts. In contrast, serum showed vascular injuries and acute inflammation in response to radiation. Selected urinary exosomal biomarkers also showed changes at lower radiation doses in validation studies. Conclusions: Exosome proteomics revealed radiation- and time-dependent protein signatures after WBI. A total of 47 differentially secreted proteins were identified in urinary and serum exosomes. Together, these data showed the feasibility of defining biomarkers that could elucidate tissue-associated and systemic response caused by high-dose ionizing radiation. This is the first report using an exosome proteomics approach to identify radiation signatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk Assessment in a Chemical Laboratory Following an Explosive Incident Involving a Novel Diazonium Compound: Retrospective Analysis and Lessons Learned

Diazonium compounds are synthetically useful in the production of dyes and textiles, however they are highly explosive under dry conditions. Explosion prevention becomes more difficult when new diazonium compounds are synthesized, because while some syntheses include a counterion to increase their stability, this is not always a reliable method to prevent an explosive incident. Due to the uncertainty surrounding the explosiveness of different diazonium compounds, it is important to understand how to safely clean up after an incident and how to determine when it is safe to return a laboratory to typical operational use, particularly when the incident involves a novel compound where a standard does not exist for instrument calibration. Here, an explosive event is discussed involving the synthesis of 4-bromo-benzenediazonium-2-carboxylate. Following the explosive incident and 3-step cleanup, which involved a precautionary neutralization step, samples were collected from the fume hood where the incident occurred. Because the incident involved an unstable, novel compound that is not commercially available and was deemed unsafe to resynthesize for instrument calibration, we assessed the risk of further explosion by analyzing for the stable decomposition products. Mass spectrometry analysis confirmed that the residue in the fume hood contained 5-bromosalicylic acid, a decomposition product of 4-bromo-benzenediazonium-2-carboxylate. Samples were taken from multiple points in the fume hood and analyzed to estimate the spatial distribution of the decomposition product. Based on this analysis, we inferred that the primary decomposition product was far more abundant than residual energetic, indicating the energetic had been consumed or neutralized to a trace quantity where the risk of further explosion was low. Furthermore, the steps presented here─specifically, initial neutralization and then analyzing the spatial distribution of expected decomposition products to assess risk when a novel explosive material is detonated in a confined space─were our approach to assess further risk following an explosion due to a novel diazonium compound without the need for any further handling or resynthesis of the energetic. Here, we present our approach and critically analyze these steps by discussing retrospective lessons learned and alternative analytical approaches.

Computer simulations↗