Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Two-Step Procedure to Detect Cosmological Gravitational Wave Backgrounds with Next-Generation Terrestrial Gravitational-Wave Detectors

Cosmological gravitational-wave backgrounds are an exciting science target for next-generation ground-based detectors, as they encode invaluable information about the primordial Universe. However, any such background is expected to be obscured by the astrophysical foreground from compact-binary coalescences. We propose a novel framework to detect a cosmological gravitational-wave background in the presence of binary black holes and binary neutron star signals with next-generation ground-based detectors, including Cosmic Explorer and the Einstein Telescope. Our procedure involves first removing all the individually resolved binary black hole signals by notching them out in the time-frequency domain. Then, we perform joint Bayesian inference on the individually resolved binary neutron star signals, the unresolved binary neutron star foreground, and the cosmological background. For a flat cosmological background, we find that we can claim detection at 5⁢𝜎 level when Ω ref ≥ 2.7 × 10 −12 /$\sqrt{𝑇_{obs}/yr}$, where 𝑇 obs is the observation time (in years), which is within a factor of ≲ 2 from the sensitivity reached in the absence of these astrophysical foregrounds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional culture of sebaceous gland cells revealing the role of prostaglandin E{sub 2}-induced activation of canonical Wnt signaling

Highlights: •Three-dimensional culture generates “semi-vivo” sebaceous glands. •Xenograft model failed to mimic the biology of sebaceous glands in vivo. •Proinflammatory cytokine PGE{sub 2} enhances Wnt signal activity in the organoids. •PGE{sub 2} influences on the mitochondrial and lipid metabolism in the organoids. •Considering 3R agenda, “semi-vivo” sebaceous glands are useful for research. -- Abstract: Background: Prostaglandin E{sub 2} (PGE{sub 2}) is a proinflammatory mediator and activates the canonical Wnt–β-catenin signaling pathway in hematopoietic stem cells. The SZ95 cell line was established from human sebaceous gland cells and is studied as a model system for these cells. Given that 2D culture of SZ95 cells does not recapitulate the organization of sebaceous glands in situ, we developed a 3D culture system for these cells and examined the effects of PGE{sub 2} on cell morphology and function. Results: SZ95 cells maintained in 3D culture formed organoids that mimicked the organization of sebaceous glands in situ, including the establishment of a basement membrane. Organoids exposed to PGE{sub 2} were larger and adopted a more complex organization compared with control organoids. PGE{sub 2} activated the canonical Wnt signaling pathway as well as increased cell viability and proliferation, mitochondrial metabolism, and lipid synthesis in the organoids. Conclusions: Culture of SZ95 cells in 3D culture system recapitulates the structure and susceptibility to PGE{sub 2} of sebaceous glands in situ and should prove useful for studies of the response of these glands to inflammation and other environmental stressors. Our results also implicate PGE{sub 2}-induced activation of canonical Wnt signaling pathway in regulation of the morphology,proliferation, and function of “semi-vivo” sebaceous glands.

60 APPLIED LIFE SCIENCES↗

Patterns of genomic variation in Coho salmon following reintroduction to the interior Columbia River

Abstract Coho salmon were extirpated in the mid‐20th century from the interior reaches of the Columbia River but were reintroduced with relatively abundant source stocks from the lower Columbia River near the Pacific coast. Reintroduction of Coho salmon to the interior Columbia River (Wenatchee River) using lower river stocks placed selective pressures on the new colonizers due to substantial differences with their original habitat such as migration distance and navigation of six additional hydropower dams. We used restriction site‐associated DNA sequencing ( RAD ‐seq) to genotype 5,392 SNP s in reintroduced Coho salmon in the Wenatchee River over four generations to test for signals of temporal structure and adaptive variation. Temporal genetic structure among the three broodlines of reintroduced fish was evident among the initial return years (2000, 2001, and 2002) and their descendants, which indicated levels of reproductive isolation among broodlines. Signals of adaptive variation were detected from multiple outlier tests and identified candidate genes for further study. This study illustrated that genetic variation and structure of reintroduced populations are likely to reflect source stocks for multiple generations but may shift over time once established in nature.

Campbell, Nathan R.↗

Very high resolution radiometer

A primary sensor used in environmental and earth-resource observation, the Very High Resolution Radiometer (VHRR) was designed for use on the ITOS D series spacecraft. The VHRR provides a 0.47 mile resolution made possible with a mercury-cadmium-telluride detector cooled to approximately 105 K by a passive radiator cooler. The components of this system are described. The optical subsystem of the VHRR consists of a scanning mirror, a Dall-Kirkham telescope, a dichroic beam splitter, relay lenses, spectral filters, and an IR detector. Signal electronics amplify and condition the signals from the infrared and visible light detector. Sync generator electronics provides the necessary time signals. Scan-drive electronics is used for commutation of the motor winding, velocity, and phase control. A table lists the performance parameters of the VHRR.

Aronson, A. I.↗

Optical Quantum Receiver For Binary Signals

In quantum optical receiver, both amplitude and phase of received optical signal measured to extract as much information as possible, thereby reducing error probability. Phase-modulated received signal mixed with equal amplitude replica of optical carrier generated in phase locked loop. Two signals interfere with each other at photomultiplier cathode. Probability of error with this scheme close to theoretical minimum and implemented with current technology.

Vilnrotter, V. A.↗

Footwear scanning systems and methods

Footwear scanning systems and associated methods are described. According to one aspect, a footwear scanning system includes a base, a shuttle configured to rotate beneath the base, wherein the shuttle comprises an antenna array configured to transmit electromagnetic waves through the base into footwear above the base during the rotation of the shuttle and to receive electromagnetic waves reflected from the footwear during the rotation of the shuttle, a transceiver coupled with the antenna array and configured to apply electrical signals to the antenna array to generate the transmitted electromagnetic waves and to receive electrical signals from the antenna array corresponding to the received electromagnetic waves, and processing circuitry configured to process an output of the transceiver corresponding to the received electromagnetic waves to provide information regarding contents within the footwear.

Jones, A. Mark↗

A Polarized High-Energy Photon Beam for Production of Exotic Mesons

This work describes design, prototyping and testing of various components of the Jefferson Lab Hall D photon beamline. These include coherent bremsstrahlung radiators to be used in this facility for generating the photon beam, a fine resolution hodoscope for the facility's tagging spectrometer, and a photon beam position sensor for stabilizing the beam on a collimator. The principal instrumentation project was the hodoscope: its design, implementation and beam testing will be thoroughly described. Studies of the coherent bremsstrahlung radiators involved X-ray characterization of diamond crystals to identify the appropriate line of manufactured radiators and the proper techniques for thinning them to the desired specification of the beamline. The photon beam position sensor project involved completion of a designed detector and its beam test. The results of these shorter studies will also be presented. The second part of this work discusses a Monte Carlo study of a possible photo-production and decay channel in the GlueX experiment that will be housed in the Hall D facility. Specifically, the γ p → Xp → b 1 π → ω π +1 π -1 channel was studied including its Amplitude Analysis. This exercise attempted to generate a possible physics signal, complete with internal angular momentum states, and be able to reconstruct the signal in the detector and find the proper set of JPC quantum numbers through an amplitude fit. Derivation of the proper set of amplitudes in the helicity basis is described, followed by a discussion of the implementation, generation of the data sets, reconstruction techniques, the amplitude fit and results of this study.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A National Program for Analysis of the Climate System

Perhaps the single greatest roadblock to fundamental advances in our understanding of climate variability and climate change is the lack of robust and unbiased long-term global observations of the climate system. Such observations are critical for the identification and diagnosis of climate variations, and provide the constraints necessary for developing and validating climate models. The first generation of reanalysis efforts, by using fixed analysis systems, eliminated the artificial climate signals that occurred in analyses generated at the operational numerical weather prediction centers. These datasets are now widely used by the scientific community in a variety of applications including atmosphere-ocean interactions, seasonal prediction, climate monitoring, the hydrological cycle, and a host of regional and other diagnostic studies. These reanalyses, however, had problems that made them sub-optimal or even unusable for some applications. Perhaps the most serious problem for climate applications was that, while the assimilation system remained fixed, changes in the observing systems did produce spurious changes in the perceived climate. The first generation reanalysis products also exposed problems with physical consistency of the products and the accurate representation of physical processes in the climate system. Examples are bias in the estimates of ocean surface fluxes, and inadequate representation of polar hydrology. In this talk, I will describe some initial plans for a national program on reananlysis. The program is envisioned to be part of an on-going activity to maintain, improve, and reprocess our record of climate observations. I will discuss various issues affecting the quality of reanalyses, with a special focus on those relevant to the ocean.

Schubert, Siegfried↗

Dynamic Networks Experiment 2: Measuring Associator Sensitivity to Signal Detection Errors

Using the Dynamic Networks Experiment 2 (DNE2) human-analyst event bulletin picks as a baseline signal detection dataset, we generate 47 additional datasets by gradually reducing their accuracy and completeness by randomly removing DNE2 picks, changing the initial phase labels from P to S and vice-versa, and injecting noise detections to simulate real-world signal detection algorithms.

58 GEOSCIENCES↗

Multi-Dimensional Spectroscopy with Intense Entangled Beams: Entanglement-Enabled Phase Matching in a Collinear Beam Geometry

The experimental realization of quantum molecular spectroscopy with entangled photons remains challenging owing to the low signal-to-noise ratio resulting from the use of low-flux entangled photons. High-flux entangled photons via intense entangled beams can be used to improve the signal-to-noise ratio, but the presence of unentangled photons contaminates the quantum signal stemming from entangled photons. Here, we demonstrate how intense entangled beams can be used in multi-dimensional spectroscopy while retaining the advantage of photon entanglement. Our approach is broadly applicable to odd-ordered nonlinear spectroscopies, and it generates purely quantum spectroscopic signals. The proposed approach allows the recording of desired phase-matched signals even in a collinear beam geometry, which lifts the requirement of complicated beam geometry setups for phase matching in multi-dimensional spectroscopies.

Absorption spectroscopy↗

Sensitive Infrared Signal Detection by Upconversion Technique

We demonstrated upconversion assisted detection of a 2.05-micron signal by sum frequency generation to generate a 700-nm light using a bulk periodically poled lithium niobate crystal. The achieved 94% intrinsic upconversion efficiency and 22.58% overall detection efficiency at a pW level of 2.05 micron pave the path to detect extremely weak infrared (IR) signals for remote sensing applications.

Wong, Teh-Hwa↗

Acoustic camera

Apparatus for generating accurate 3-dimensional images of objects immersed in liquids including optically opaque liquids which may also have significant sound attenuation, is described. Sound pulses are caused to impinge on the object, and the time-of-flight of the reflected sound is used to create a 3-dimensional image of the object in almost real-time. The apparatus is capable of creating images of objects immersed in fluids that are optically opaque and have high sound attenuation at resolutions less than about 1 mm. The apparatus may include a piezoelectric transducer for generating the acoustic pulses; a high-density polyethylene compound acoustic lens, a 2-dimensional segmented piezoelectric detecting array positioned behind the lens for receiving acoustic pulses reflected by the object, the electric output of which is directed to digital signal processing electronics for generating the image.

47 OTHER INSTRUMENTATION↗

Bayesian Structural Time Series for Behind-the-Meter Photovoltaic Disaggregation

Distributed photovoltaic (PV) generation often occurs ``behind the meter": a grid operator can only observe the net load, which is the sum of the gross load and distributed PV generation. This lack of observability poses a challenge to system operation at both bulk level and distribution level. The lack of real-time or near-future disaggregated estimates of gross load and PV generation will lead to over scheduling of energy production and regulation reserves, reliability constraints violations, wear and tear of controller devices, and potentially cascading failures of a system. In this paper we propose the use of a Bayesian Structural Time Series (BSTS) model with local solar irradiance measurements to disaggregate the summed PV generation and gross load signals at a downstream measurement site. BSTSs are a highly expressive model class that blends classic time series models with the powerful Bayesian state space estimation framework. Disaggregation is done probabilistically, which automatically quantifies the uncertainties of the estimated PV generation and gross load consumption. Depending on the data availability in real-time, it can be used to disaggragate PV and gross load at customer site, or can be used at the feeder level. In this paper, we focus on solving the problem at feeder level. We compare the performance of a BSTS model as well as a handful of state-of-the-art methods on a Pecan Street AMI dataset, using the National Solar Radiation Database (NSRDB) to estimate local irradiance.

bayesian structural time series↗

Comparison of Different Classical, Semiclassical, and Quantum Treatments of Light–Matter Interactions: Understanding Energy Conservation

The optical response of an electronic two-level system (TLS) coupled to an incident continuous wave (cw) electromagnetic (EM) field is simulated explicitly in one dimension by the following five approaches: (i) the coupled Maxwell-Bloch equations, (ii) the optical Bloch equation (OBE), (iii) Ehrenfest dynamics, (iv) the Ehrenfest+R approach, and (v) classical dielectric theory (CDT). Our findings are as follows: (i) standard Ehrenfest dynamics predict the correct optical signals only in the linear response regime where vacuum fluctuations are not important; (ii) both the coupled Maxwell-Bloch equations and CDT predict incorrect features for the optical signals in the linear response regime due to a double-counting of self-interaction; (iii) by exactly balancing the effects of self-interaction versus the effects of quantum fluctuations (and insisting on energy conservation), the Ehrenfest+R approach generates the correct optical signals in the linear regime and slightly beyond, yielding, e.g., the correct ratio between the coherent and incoherent scattering EM fields. Furthermore, Ehrenfest+R dynamics agree with dynamics from the quantum OBE, but whereas the latter is easily applicable only for a single TLS in vacuum, the former should be applicable to large systems in environments with arbitrary dielectrics. Hence, this benchmark study suggests that the Ehrenfest+R approach may be very advantageous for simulating light-matter interactions semiclassically.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-163: A Biomechanical Lung Model for Respiratory Motion Study

Purpose: This work presents a biomechanical model to investigate the complex respiratory motion for the lung tumor tracking in radiosurgery by computer simulation. Methods: The models include networked massspring-dampers to describe the tumor motion, different types of surrogate signals, and the force generated by the diaphragm. Each mass-springdamper has the same mechanical structure and each model can have different numbers of mass-spring-dampers. Both linear and nonlinear stiffness parameters were considered, and the damping ratio was tuned in a range so that the tumor motion was over-damped (no natural tumor oscillation occurs without force from the diaphragm). The simulation was run by using ODE45 (ordinary differential equations by Runge-Kutta method) in MATLAB, and all time courses of motions and inputs (force) were generated and compared. Results: The curvature of the motion time courses around their peaks was sensitive to the damping ratio. Therefore, the damping ratio can be determined based on the clinical data of a high sampling rate. The peak values of different signals and the time the peaks occurred were compared, and it was found that the diaphragm force had a time lead over the tumor motion, and the lead time (0.1–0.4 seconds) depended on the distance between the tumor and the diaphragm. Conclusion: We reported a model based analysis approach for the spatial and temporal relation between the motion of the lung tumor and the surrogate signals. Due to the phase lead of the diaphragm in comparing with the lung tumor motion, the measurement of diaphragm motion (or its electromyography signal) can be used as a beam gating signal in radiosurgery, and it can also be an additional surrogate signal for better tumor motion tracking. The research is funded by the American Cancer Society (ACS) grant. The grant name is: Frameless SRS Based on Robotic Head Motion Cancellation. The grant number is: RSG-13-313-01-CCE.

60 APPLIED LIFE SCIENCES↗

Neutron monitoring systems including gamma thermometers and methods of calibrating nuclear instruments using gamma thermometers

A method of calibrating a nuclear instrument using a gamma thermometer may include: measuring, in the instrument, local neutron flux; generating, from the instrument, a first signal proportional to the neutron flux; measuring, in the gamma thermometer, local gamma flux; generating, from the gamma thermometer, a second signal proportional to the gamma flux; compensating the second signal; and calibrating a gain of the instrument based on the compensated second signal. Compensating the second signal may include: calculating selected yield fractions for specific groups of delayed gamma sources; calculating time constants for the specific groups; calculating a third signal that corresponds to delayed local gamma flux based on the selected yield fractions and time constants; and calculating the compensated second signal by subtracting the third signal from the second signal. The specific groups may have decay time constants greater than 5.times.10.sup.-1 seconds and less than 5.times.10.sup.5 seconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant Transmissive Modulator Construction for Use in Beam Steering Array

An agile electronically configurable optical beam steering device for use in directional free-space transmission of optical signals is described. The device design employs an array of tunable resonant transmissive modulators constructed from multi-layered stacks of electro-optically active dielectric materials. Each modulator may be individually configured to transmit an optical signal with a specific amount of phase and group velocity modulation. The resulting diffractive interactions between modulator outputs provide a method for directional optical signal transmission. Of particular focus within this presentation is the optimized design of the individual modulator. It is widely known that periodic multi-layered stacks of dielectric materials exhibit reflective and transmissive resonances as described by the stack's transmission function. If an electric field is applied normal to the stack's layers, phenomena such as the electro-optic effect and/or the quantum-confined Stark effect may be employed to change the effective refractive index within the stack. This refractive index change alters the stack's transmission function and modulates the phase and group velocity of the transmitted optical signal. By varying the parameters that describe the stack's specific construction and operation, such as number of layers within the stack, refractive indexes of stack materials, layer thicknesses, and combinations of periodic verses non-periodic layer repetitions, custom transmittance functions may be generated. The transmitted optical signal carrier frequency and bandwidth must be carefully selected to maximize transmission and to minimize absorption. A computational optimization of the variables describing the stack's construction strives to maximize the amount of optical signal modulation verses applied voltage. Trade-offs between methods of increasing device performance verses the limitations of fabrication technologies are considered.

Keys, Andrew S.↗