Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Spatial diagnostics of the laser induced lithium fluoride plasma

We present spatial characteristics of the lithium fluoride plasma generated by the fundamental and second harmonic of a Nd:YAG laser. The plume emission has been recorded spatially using five spectrometers covering the spectral region from 200 nm to 720 nm. The electron density is measured from the Stark broadened line profile of the line at 610.37 nm, whereas the plasma temperature has been determined using the Boltzmann plot method including all the observed spectral lines of lithium. Both the plasma parameters; electron density and plasma temperature decrease with the increase of the distance from the target surface. The thermal conduction towards the target, the radiative cooling of the plasma, and the conversion of thermal energy into kinetic energy are the main mechanisms responsible for the spatially decrease of the plasma parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulating signatures of two-dimensional electronic spectra of the Fenna-Matthews-Olson complex: By using a numerical path integral

A framework for simulating electronic spectra from photon-echo experiments is constructed by using a numerical path integral technique. This method is non-Markovian and nonperturbative and, more importantly, is not limited by a fixed form of the spectral density functions of the environment. Next, a two-dimensional (2D) third-order electronic spectrum of a dimer system is simulated. The spectrum is in agreement with the experimental and theoretical results previously reported [for example, M. Khalil, N. Demirdöven, and A. Tokmakoff, Phys. Rev. Lett. 90, 047401 (2003)]. Finally, a 2D third-order electronic spectrum of the Fenna-Matthews-Olson (FMO) complex is simulated by using the Debye, Ohmic, and Adolphs and Renger spectral density functions. It is shown that this method can clearly produce the spectral signatures of the FMO complex by using only the Adolphs and Renger spectral density function. Plots of the evolution of the diagonal and cross-peaks show that they are oscillating with the population time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Two Methodologies for Calibrating Satellite Instruments in the Visible and Near Infrared

Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance response in a two-step method. In the first step, the spectral response of the instrument is determined using a nearly monochromatic light source, such a lamp-illuminated monochromator. Such sources only provide a relative spectral response (RSR) for the instrument, since they do not act as calibrated sources of light nor do they typically fill the field-of-view of the instrument. In the second step, the instrument views a calibrated source of broadband light, such as lamp-illuminated integrating sphere. In the traditional method, the RSR and the sphere spectral radiance are combined and, with the instrument's response, determine the absolute spectral radiance responsivity of the instrument. More recently, an absolute calibration system using widely tunable monochromatic laser systems has been developed, Using these sources, the absolute spectral responsivity (ASR) of an instrument can be determined on a wavelength-hy-wavelength basis. From these monochromatic ASRs. the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as integrating spheres. Here we describe the laser-based calibration and the traditional broad-band source-based calibration of the NPP VIIRS sensor, and compare the derived calibration coefficients for the instrument. Finally, we evaluate the impact of the new calibration approach on the on-orbit performance of the sensor.

Barnes, Robert A.↗

Systems and methods for selective detection and imaging in coherent Raman microscopy by spectral excitation shaping

A microscopy imaging system is disclosed that includes a light source system, a spectral shaper, a modulator system, an optics system, an optical detector and a processor. The light source system is for providing a first train of pulses and a second train of pulses. The spectral shaper is for spectrally modifying an optical property of at least some frequency components of the broadband range of frequency components such that the broadband range of frequency components is shaped producing a shaped first train of pulses to specifically probe a spectral feature of interest from a sample, and to reduce information from features that are not of interest from the sample. The modulator system is for modulating a property of at least one of the shaped first train of pulses and the second train of pulses at a modulation frequency. The optical detector is for detecting an integrated intensity of substantially all optical frequency components of a train of pulses of interest transmitted or reflected through the common focal volume. The processor is for detecting a modulation at the modulation frequency of the integrated intensity of substantially all of the optical frequency components of the train of pulses of interest due to the non-linear interaction of the shaped first train of pulses with the second train of pulses as modulated in the common focal volume, and for providing an output signal for a pixel of an image for the microscopy imaging system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bounds on spectral gaps of Hyperbolic spin surfaces

We describe a method for constraining Laplacian and Dirac spectra of two dimensional compact orientable hyperbolic spin manifolds and orbifolds. The key ingredient is an infinite family of identities satisfied by the spectra. These spectral identities follow from the consistency between 1) the spectral decomposition of functions on the spin bundle into irreducible representations of SL(2,R) and 2) associativity of pointwise multiplication of functions. Applying semidefinite programming methods to our identities produces rigorous upper bounds on the Laplacian spectral gap as well as on the Dirac spectral gap conditioned on the former. In several examples, our bounds are nearly sharp; a numerical algorithm based on the Selberg trace formula shows that the [0;3,3,5] orbifold, a particular surface with signature [1;3], and the Bolza surface nearly saturate the bounds at genus 0, 1 and 2 respectively. Under additional assumptions on the number of harmonic spinors carried by the spin-surface, we obtain more restrictive bounds on the Laplacian spectral gap. In particular, these bounds apply to hyperelliptic surfaces. We also determine the set of Laplacian spectral gaps attained by all compact orientable two-dimensional hyperbolic spin orbifolds. We show that this set is upper bounded by 12.13798; this bound is nearly saturated by the [0;3,3,5] orbifold, whose first non-zero Laplacian eigenvalue is λ^(0)_1 ≈ 12.13623.

Spectral theory↗

Signal Processsing for Sounding Rocket Flights: Campaign No. 2 Results

Sounding rockets provide both a viable and convenient alternative to more costly missile flights with one of the major objectives being to test various types of sensors for monitoring components of high interest as well as developing real-time signal processing techniques. Signal processing, especially in real-time, presents an extreme challenge in this noisy flight environment. The estimation and tracking of modal frequencies from vibrating structures is the an important set of features that can provide information about the components under test; therefore, high resolution multichannel spectral processing is required. In this report we discuss the application of both single/multichannel techniques that can be applied to solve this challenging problem in the case of noisy, uncertain accelerometer measurements. The approach involves the selection of methods capable of producing reliable spectral estimates corresponding to the modal frequencies of a vibrating structure.

42 ENGINEERING↗

Verifying the Presence of Low Levels of Neptunium in a Uranium Matrix with Electron Energy-Loss Spectroscopy

This paper examines the problems associated with the analysis of low levels of neptunium (Np) in a uranium (U) matrix with electron energy-loss spectroscopy (EELS) on the transmission electron microscope (TEM). The detection of Np in a matrix of uranium (U) can be impeded by the occurrence of a plural scattering event from U (U-M5 + U-O4,5) that results in severe overlap on the Np-M5 edge at 3665 eV. Low levels (1600 - 6300 ppm) of Np can be detected in U solids by confirming the energy gap between the Np-M5 and Np-M4 edges is at 184 eV and showing that the M4/M5 ratio for the Np is smaller than that for U. The Richardson-Lucy deconvolution method was applied to energy-loss spectral images and was shown to increase the signal to noise. This method also improves the limits of detection for Np in a U matrix.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fourier-informed knot placement schemes for B-spline approximation

Fitting B-splines to scientific data is especially challenging when the given data contain noise, jumps, or corners. Here, we describe how periodic data sets with these features can be efficiently approximated with B-splines by analyzing the Fourier spectrum of the data. Our method uses a collection of spectral filters to compute high-order derivatives, smoothed versions of noisy data, and the locations of jump discontinuities. Further, these quantities are then combined to choose knots that capture the qualitative features of the data, leading to accurate B-spline approximations with few knots. The method we introduce is direct and does not require any intermediate B-spline fitting before choosing the final knot distribution. Aside from fast Fourier transforms to transfer to and from Fourier space, the method runs in linear time with very little communication. We assess performance on several test cases in one and two dimensions, including data sets with jump discontinuities and noise. These tests show the method fits discontinuous data without spurious oscillations and remains effective in the presence of noise.

97 MATHEMATICS AND COMPUTING↗

On the numerical accuracy in finite-volume methods to accurately capture turbulence in compressible flows

The goal of the present article is to understand the impact of numerical schemes for the reconstruction of data at cell faces in finite-volume methods, and to assess their interaction with the quadrature rule used to compute the average over the cell volume. Here, third-, fifth- and seventh-order WENO-Z schemes are investigated. On a problem with a smooth solution, the theoretical order of convergence rate for each method is retrieved, and changing the order of the reconstruction at cell faces does not impact the results, whereas for a shock-driven problem all the methods collapse to first-order. Here, study of the decay of compressible homogeneous isotropic turbulence reveals that using a high-order quadrature rule to compute the average over a finite-volume cell does not improve the spectral accuracy and that all methods present a second-order convergence rate. However the choice of the numerical method to reconstruct data at cell faces is found to be critical to correctly capture turbulent spectra. In the context of simulations with finite-volume methods of practical flows encountered in engineering applications, it becomes apparent that an efficient strategy is to perform the average integration with a low-order quadrature rule on a fine mesh resolution, whereas high-order schemes should be used to reconstruct data at cell faces.

97 MATHEMATICS AND COMPUTING↗

Classification of gaseous UF 6 assay by femtosecond LIBS in the 424.4 nm spectral region using numerical HOGSVD-DTW features

This technical note presents experimental results using numerical features of fs-LIBS data to classify the assay value of a gaseous UF 6 material. Here, the data-driven feature vectors are computed by Higher Order Generalized Singular Value Decomposition (HOGSVD) and Dynamic Time Warp (DTW). The method achieves 96.97% accuracy in spectral classification testing with fs-LIBS samples obtained from a UF 6 material with five known assay values ranging from 0.287% to 61.740%, with 100% accuracy for the four largest assay values ranging from 4.615% to 61.740%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MODELING MOLECULAR HYPERFINE LINE EMISSION

In this paper, we discuss two approximate methods previously suggested for modeling hyperfine spectral line emission for molecules whose collisional transition rates between hyperfine levels are unknown. Hyperfine structure is seen in the rotational spectra of many commonly observed molecules such as HCN, HNC, NH{sub 3}, N{sub 2}H{sup +}, and C{sup 17}O. The intensities of these spectral lines can be modeled by numerical techniques such as {Lambda}-iteration that alternately solve the equations of statistical equilibrium and the equation of radiative transfer. However, these calculations require knowledge of both the radiative and collisional rates for all transitions. For most commonly observed radio frequency spectral lines, only the net collisional rates between rotational levels are known. For such cases, two approximate methods have been suggested. The first method, hyperfine statistical equilibrium, distributes the hyperfine level populations according to their statistical weight, but allows the population of the rotational states to depart from local thermal equilibrium (LTE). The second method, the proportional method, approximates the collision rates between the hyperfine levels as fractions of the net rotational rates apportioned according to the statistical degeneracy of the final hyperfine levels. The second method is able to model non-LTE hyperfine emission. We compare simulations of N{sub 2}H{sup +} hyperfine lines made with approximate and more exact rates and find that satisfactory results are obtained.

74 ATOMIC AND MOLECULAR PHYSICS↗

Theoretical and experimental physical methods of neutron-capture therapy

This review is based to a substantial degree on our priority developments and research at the IR-8 reactor of the Russian Research Centre Kurchatov Institute. New theoretical and experimental methods of neutron-capture therapy are developed and applied in practice; these are: A general analytical and semi-empiric theory of neutron-capture therapy (NCT) based on classical neutron physics and its main sections (elementary theories of moderation, diffuse, reflection, and absorption of neutrons) rather than on methods of mathematical simulation. The theory is, first of all, intended for practical application by physicists, engineers, biologists, and physicians. This theory can be mastered by anyone with a higher education of almost any kind and minimal experience in operating a personal computer. Methods: of phantom experimental studies for the semi-empiric theory of NCT using epithermal neutrons. Experimental methods for measuring and monitoring the spectral composition of therapeutic, research, and analytical neutron beams for NCT and other investigations with neutrons. Experimental methods of remote neutron dosimetry of biological objects with intentional modification of the element composition of tissues in NCT. Methods: of mass investigations in pharmacokinetics and biologic efficiency of novel dose-forming preparations. Methods: for tailoring of therapeutic, research, and analytical neutron beams for NCT and other investigations with neutrons. Methods: of capillary neutron optics application for NCT and other fundamental and applied studies with neutrons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spectrally Stabilized Interface Capturing Formulation and Implementation in Nek5000/NekRS

This report documents the formulation of a novel level-set method for incompressible two-phase flows in the continuous Galerkin (CG) high order spectral element framework. The overall method hinges on a novel implementation of the spectral vanishing viscosity (SVV) operator for the stabilization of linear/non-linear hyperbolic problems. The multidimensional SVV convolution kernels, which in essence, have a similar effect as a high pass filter applied to the derivatives, are formulated by exploiting the tensor product form, analogous to the construction of the usual stiffness matrix system. The resulting kernels are directionally decoupled and ensure a linear, symmetric positive definite, elliptic matrix operator. The SVV formulation is demonstrated to provide a robust stabilizing mechanism through challenging linear and non-linear hyperbolic problems, including problems pertinent to the level-set formulation. The two-phase framework conceptualized herein is based on the conservative level-set (CLS) method which represents the interface between the fluids by the 0.5 iso-contour of the smoothed Heaviside function. The CLS method is augmented with a preconditioning procedure for interface normals using the signed distance function which precludes the manifestation of spurious oscillations in the vicinty of the interface. Further, the existing mixed explicit-implicit approach for the solution of Navier-Stokes equations in Nek5000, as described in Tomboulides et al, is augmented with a pressure coefficient splitting approach for the Poisson equation, which greatly accelerated the convergence of pressure solver for two-phase systems with large density ratio. The robustness and accuracy of the overall two-phase method is demonstrated through canonical challenging problems involving high density and viscosity ratios, with and without surface tension. The two-phase formulation is wholly implemented in Nek5000 and the SVV stabilization method is implemented in NekRS, which is the essential precursor to the two-phase framework, undergoing active development.

97 MATHEMATICS AND COMPUTING↗

Establishing temperature from radiance of dynamically compressed metals

Precise temperature determination is a significant challenge in extreme environments of dynamic compression studies. How can radiance measurements taken in high-pressure shock experiments constrain temperature in a meaningful and physically consistent way? Experiments maintaining sample compression against a transparent window can be tailored to present a uniform measurement area with uncertain spectral emissivity. We compare several methods to analyze radiance collected at multiple wavelengths, applying statistical methods and physical principles to improve temperature inference. With proper radiance collection and analysis, dynamic temperature uncertainties become comparable to thermomechanical ambiguities of the emitting surface.

36 MATERIALS SCIENCE↗

ACCOUNTING FOR CALIBRATION UNCERTAINTIES IN X-RAY ANALYSIS: EFFECTIVE AREAS IN SPECTRAL FITTING

While considerable advance has been made to account for statistical uncertainties in astronomical analyses, systematic instrumental uncertainties have been generally ignored. This can be crucial to a proper interpretation of analysis results because instrumental calibration uncertainty is a form of systematic uncertainty. Ignoring it can underestimate error bars and introduce bias into the fitted values of model parameters. Accounting for such uncertainties currently requires extensive case-specific simulations if using existing analysis packages. Here, we present general statistical methods that incorporate calibration uncertainties into spectral analysis of high-energy data. We first present a method based on multiple imputation that can be applied with any fitting method, but is necessarily approximate. We then describe a more exact Bayesian approach that works in conjunction with a Markov chain Monte Carlo based fitting. We explore methods for improving computational efficiency, and in particular detail a method of summarizing calibration uncertainties with a principal component analysis of samples of plausible calibration files. This method is implemented using recently codified Chandra effective area uncertainties for low-resolution spectral analysis and is verified using both simulated and actual Chandra data. Our procedure for incorporating effective area uncertainty is easily generalized to other types of calibration uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Algebraic reconstruction techniques for spectral reconstruction in diffuse optical tomography

Reconstruction in diffuse optical tomography (DOT) necessitates solving the diffusion equation, which is nonlinear with respect to the parameters that have to be reconstructed. Currently applied solving methods are based on the linearization of the equation. For spectral three-dimensional reconstruction, the emerging equation system is too large for direct inversion, but the application of iterative methods is feasible. Computational effort and speed of convergence of these iterative methods are crucial since they determine the computation time of the reconstruction. In this paper, the iterative methods algebraic reconstruction technique (ART) and conjugated gradients (CGs) as well as a new modified ART method are investigated for spectral DOT reconstruction. The aim of the modified ART scheme is to speed up the convergence by considering the specific conditions of spectral reconstruction. As a result, it converges much faster to favorable results than conventional ART and CG methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of four subcritical response methods for on-line prediction flutter onset in wind-tunnel tests

The methods were evaluated for use in tests where the flutter model is excited solely by airstream turbulence. The methods were: randomdec, power-spectral-density, peak-hold, and cross-spectrum. The test procedure was to maintain a constant Mach number (M) and increase the dynamic pressure (g) in incremental steps. The test Mach numbers were 0.65, 0.75, 0.82, 0.90, and 1.15. The four methods provided damping trends by which the flutter mode could be tracked and extrapolated to a flutter-onset q. A hard flutter point was obtained at M = 0.82. The peak-hold and cross-spectrum methods gave reliable results and could be most readily used for on-line testing. At M = 0.82, a p-k analysis predicted the same flutter mode as the experiment but a 6-percent lower flutter q. At the subcritical dynamic pressures, calculated damping values were appreciably lower than measured data.

Ruhlin, C. L.↗

Machine boundary finding and sample classification of remotely sensed agricultural data

A method based on the use of spectral variations in combination with spatial variations is developed for automatic boundary finding and sample classification of remotely sensed multispectral data. Preliminary applications of the method to agricultural data show significant improvements in accuracy as compared to the use of spectral data alone.

Gupta, J. N.↗