Search NASA⌕ Search

SEARCH · Search NASA

Results for “Technology data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Development of a Twin-Screw D-2 Extruder for the ITER Pellet Injection System

A twin-screw extruder for the ITER pellet injection system is under development at the Oak Ridge National Laboratory. The extruder will provide a stream of solid hydrogen isotopes to a secondary section, where pellets are cut and accelerated with single-stage gas gun into the plasma. A one-fifth ITER scale prototype extruder has been built to produce a continuous solid deuterium extrusion. Deuterium gas is precooled and liquefied before being introduced into the extruder. The precooler consists of a copper vessel containing liquid nitrogen surrounded by a deuterium gas filled copper coil. The liquefier is comprised of a copper cylinder connected to a Cryomech AL330 cryocooler, which is surrounded by a copper coil that the precooled deuterium flows through. The lower extruder barrel is connected to a Cryomech GB-37 cryocooler to solidify the deuterium (at approximate to 15 K) before it is forced through the extruder nozzle. A viewport located below the extruder nozzle provides a direct view of the extrusion. A camera is used to document the extrusion quality and duration. A data acquisition system records the extruder temperatures, torque, and speed, upstream, and downstream pressures. This paper will describe the prototype twin-screw extruder and initial extrusion results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prognostic Analysis of the Tactical Quiet Generator

The U.S. Army needs prognostic analysis of mission-critical equipment to enable condition-based maintenance before failure. ORNL has developed and patented prognostic technology that quantifies condition change from noisy, multi-channel, time-serial data. This report describes an initial application of ORNL's prognostic technology to the Army's Tactical Quiet Generator (TQG), which is designed to operate continuously at 10 kW. Less-than-full power operation causes unburned fuel to accumulate on internal components, thereby degrading operation and eventually leading to failure. The first objective of this work was identification of easily-acquired, process-indicative data. Two types of appropriate data were identified, namely output-electrical current and voltage, plus tri-axial acceleration (vibration). The second objective of this work was data quality analysis to avoid the garbage-in-garbage-out syndrome. Quality analysis identified more than 10% of the current data as having consecutive values that are constant, or that saturate at an extreme value. Consequently, the electrical data were not analyzed further. The third objective was condition-change analysis to indicate operational stress under non-ideal operation and machine degradation in proportion to the operational stress. Application of ORNL's novel phase-space dissimilarity measures to the vibration power quantified the rising operational stress in direct proportion to the less-than-full-load power. We conclude that ORNL's technology is an excellent candidate to meet the U.S. Army's need for equipment prognostication.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Unleashing the Power of Wide-Area Data Analytics for Enhanced Grid Visibility

We report that the operation of modern electric transmission systems relies increasingly on the use of advanced sensing and synchronized-measurement technologies. These technologies collect and collate a wide variety of data from disperse locations to monitor the health of network, obtain fast and accurate diagnosis of systemic changes, and detect signs of anomalies and instabilities at an early stage. In view of the far-reaching blackout risk from potential damages to critical transmission grid assets (due to severe disturbances, physical attacks, and extreme weather events), stealthy activities that compromise the operation of wide-area sensing, communication, and control systems could cripple the entire cyber-physical smart-grid infrastructure. To this end, achieving robust event identification, ensuring bulk system observability, and developing actionable intelligence (by fostering data-driven decision making under imminent threat of complex, multifaceted attacks and disruptions) remain key challenges for sustaining a resilient power grid operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber security using multi-threaded architecture data diode at the NBSR - 114

Ongoing upgrades for the control room of the National Bureau of Standards Reactor (NBSR) located at the National Institute of Standards and Technology (NIST) require the ability to collect sensor data from the secured reactor network and transfer to the outside network for trend analysis, while maintaining the security of the reactor network. To accomplish this, a data diode was created to provide a physical barrier that prevents any outside data from reaching the secured reactor network. The hardware of the data diode consists of two embedded computers, running Unix based operating systems, connected by three DB-9 serial cables. The serial cables have been modified so that only two wires, a ground and a transmission line, provide connection between the computers. The data diode relies on a multi-threaded architecture to collect and simultaneously transfer data over three serial connections. A software program, implemented in Java, has been written to request data from the digital recorders installed to monitor the NBSR process instrumentation and transfer that data across the serial connections. The data diode can collect over 1200 data points from multiple digital recorders each second. The collected data can then be stored in a relational database for later analysis. The source codes for the software are available open source on GitHub. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Data Analysis for Fusion: A Bayesian Tutorial for Fusion Diagnosticians

Integrated Data Analysis (IDA) offers a unified way of combining information relevant to fusion experiments. Thereby, IDA meets with typical issues arising in fusion data analysis. In IDA, all information is consistently formulated as probability density functions quantifying uncertainties in the analysis within the Bayesian probability theory. For a single diagnostic, IDA allows the identification of faulty measurements and improvements in the setup. For a set of diagnostics, IDA gives joint error distributions allowing the comparison and integration of different diagnostics results. Validation of physics models can be performed by model comparison techniques. Typical data analysis applications benefit from IDA capabilities of nonlinear error propagation, the inclusion of systematic effects and the comparison of different physics models. Applications range from outlier detection, background discrimination, model assessment and design of diagnostics. In order to cope with next step fusion device requirements, appropriate techniques are explored for fast analysis applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of an AGATA asymmetric detector

Each major technical advance in gamma-ray detection devices has resulted in significant new insights into the structure of atomic nuclei. The next major step in gamma-ray spectroscopy involves achieving the goal of a 4{pi} ball of germanium detectors by using the technique of gamma-ray energy tracking in electrically segmented germanium crystals. The resulting spectrometer will have an unparalleled level of detection power for nuclear electromagnetic radiation. Collaborations have been established in Europe (AGATA)[1] and the USA (GRETA/GRETINA)[2] to build gamma-ray tracking spectrometers. This paper discusses the performance of the first AGATA (Advanced GAmma Tracking Array) asymmetric detector that has been tested at the University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Life-cycle environmental impacts of single-junction and tandem perovskite PVs: a critical review and future perspectives

For new technologies, such as perovskite solar cells (PSC), life cycle analysis (LCA) offers a fundamental framework for examining potential environmental, energy and health impacts and mitigation options before large-scale commercialization and for guiding improvements in development and production that further reduce their environmental footprint. However, credible LCA studies require actual process-based material, energy and emissions data, which may not exist before the technologies are commercially produced. Thus, the perovskite LCA literature is based on linear extrapolations of laboratory data. In this paper we critically reviewed the PSC LCA literature, explain the reasoning for a wide divergence of results, and determined which data apply to scalable industrial production, materials and processes. Our investigation probed into the formulation of each layer of a PSC device, and its potential for industrial scale fabrication. We found that electricity use is the main contributor to reported LCA results, explaining the large difference, ranging from 7.78 kWh to 1,460 kWh/m –2 , among various studies. Subsequently, we identified and discuss methodological errors in some of these estimates. In terms of life-cycle toxicity most of the reviewed LCA studies do not attribute any major overall toxicity impact to the presence of lead in the PSC devices. We also reviewed and critiqued studies describing “worst-case” scenarios of accidental release of lead into the environment, and, in spite of statements in those studies, we found them to be inconclusive. Lastly, we discussed end-of-life (EoL) management options for resource recovery and for minimizing environmental impacts.

14 SOLAR ENERGY↗

Environmental performances of different configurations of a material recovery facility in a life cycle perspective

Highlights: • An attributional LCA assessed the environmental performances of an integrated MRF. • Different configurations of the MRF technological evolution have been analysed. • Reliable data provide a large LCI table for all the configurations and each sub-units. • A biological treatment in-situ improves the potentials of land occupation and global warming. • The inclusion of a small-scale gasifier could improve almost all the environmental potentials. - Abstract: The study evaluated the environmental performances of an integrated material recovery facility (MRF) able to treat 32 kt/y of unsorted mixed waste, made of residuals from household source separation and separate collection. The facility includes a mechanical sorting platform for the production of a solid recovered fuel (SRF) utilized in an external waste-to-energy plant, bio-cells for tunnel composting of organic fraction, and a sanitary landfill for the safe disposal of ultimate waste. All the MRF sub-units have been analysed in depth in order to acquire reliable data for a life cycle assessment study, focused on the environmental performances of different configurations of the facility. The study investigated a “past” configuration, including just mechanical sorting, landfilling and biogas combustion in a gas engine, and the “present” one, which includes also a composting unit. Two possible “future” configurations, having a gasifier inside the MRF battery limits, have been also analysed, assessing the performances of two fluidized bed reactors of different size, able to gasify only the residues generated by the sorting platform or the whole amount of produced SRF, respectively. The analysis evaluated the contributions of each unit in the different configurations and allowed a reliable assessment of the technological evolution of the facility. The results quantified the positive effect of the inclusion of an aerobic treatment of the waste organic fraction. The SRF gasification in situ appears to improve the MRF environmental performances in all the impact categories, with the exclusion of that of global warming.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Karst characterization in a semi-arid region using gravity, seismic, and resistivity geophysical techniques.

We proposed to customize emerging in situ geophysical monitoring technology to generate time-series data during sporadic rain events in a semi-arid region. Electrodes were to be connected to wireless \nodes" which can be left in the eld for many months. Embedded software would then increase sampling frequency during periods of rainfall. We hypothesized that this contrast between no-volume ow in karst passageways dur- ing dry periods and partial- or saturated-volume ow during a rain event is detectable by these Wireless Sensor Network (WSN) geophysical nodes, we call this a Wireless Resistivity Network (WRN). The development of new methodologies to characterize semi-arid karst hydrology is intended to augment Sandia National Laboratorys mission to lead e orts in energy technologies, waste disposal and climate security by helping to identify safe and secure regions and those that are at risk. Development and initial eld testing identi ed technological barriers to using WRNs for identifying semi-arid karst, exposing R&D which can be targeted in the future. Gravity, seismic, and resis- tivity surveys elucidated how each technique might e ectively be used to characterize semi-arid karst. This research brings to light the importance and challenges with char- acterizing semi-arid karst through a multi-method geophysical study. As there have been very few studies with this emphasis, this study has expanded the body of practical experience needed to protect the nations water and energy security interests.

Barnhart, Kevin Scott↗

Deuterium-tritium neutron yield measurements with the 4.5 m neutron-time-of-flight detectors at NIF

The first several campaigns of laser fusion experiments at the National Ignition Facility (NIF) included a family of high-sensitivity scintillator/photodetector neutron-time-of-flight (nTOF) detectors for measuring deuterium-deuterium (DD) and DT neutron yields. The detectors provided consistent neutron yield (Y{sub n}) measurements from below 10{sup 9} (DD) to nearly 10{sup 15} (DT). The detectors initially demonstrated detector-to-detector Y{sub n} precisions better than 5%, but lacked in situ absolute calibrations. Recent experiments at NIF now have provided in situ DT yield calibration data that establish the absolute sensitivity of the 4.5 m differential tissue harmonic imaging (DTHI) detector with an accuracy of {+-}10% and precision of {+-}1%. The 4.5 m nTOF calibration measurements also have helped to establish improved detector impulse response functions and data analysis methods, which have contributed to improving the accuracy of the Y{sub n} measurements. These advances have also helped to extend the usefulness of nTOF measurements of ion temperature and downscattered neutron ratio (neutron yield 10-12 MeV divided by yield 13-15 MeV) with other nTOF detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction for dynamic bias error in transmission measurements of void fraction

Dynamic bias errors occur in transmission measurements, such as X-ray, gamma, or neutron radiography or tomography. This is observed when the properties of the object are not stationary in time and its average properties are assessed. The nonlinear measurement response to changes in transmission within the time scale of the measurement implies a bias, which can be difficult to correct for. A typical example is the tomographic or radiographic mapping of void content in dynamic two-phase flow systems. In this work, the dynamic bias error is described and a method to make a first-order correction is derived. A prerequisite for this method is variance estimates of the system dynamics, which can be obtained using high-speed, time-resolved data acquisition. However, in the absence of such acquisition, a priori knowledge might be used to substitute the time resolved data. Using synthetic data, a void fraction measurement case study has been simulated to demonstrate the performance of the suggested method. The transmission length of the radiation in the object under study and the type of fluctuation of the void fraction have been varied. Significant decreases in the dynamic bias error were achieved to the expense of marginal decreases in precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic Online Monitoring for Process Control and Safeguarding of Radiochemical Fuel Reprocessing Streams - 13553

There is a renewed interest worldwide to promote the use of nuclear power and close the nuclear fuel cycle. The long term successful use of nuclear power is critically dependent upon adequate and safe processing and disposition of the used nuclear fuel. Liquid-liquid extraction is a separation technique commonly employed for the processing of the dissolved spent nuclear fuel. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. This paper discusses application of absorption and vibrational spectroscopic techniques supplemented by physicochemical measurements for radiochemical process monitoring. In this context, our team experimentally assessed the potential of Raman and spectrophotometric techniques for on-line real-time monitoring of the U(VI)/nitrate ion/nitric acid and Pu(IV)/Np(V)/Nd(III), respectively, in solutions relevant to spent fuel reprocessing. Both techniques demonstrated robust performance in the repetitive batch measurements of each analyte in a wide concentration range using simulant and commercial dissolved spent fuel solutions. Static spectroscopic measurements served as training sets for the multivariate data analysis to obtain partial least squares predictive models, which were validated using on-line centrifugal contactor extraction tests. Satisfactory prediction of the analytes concentrations in these preliminary experiments warrants further development of the spectroscopy-based methods for radiochemical safeguards and process control. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurements of collective fuel velocities in deuterium-tritium exploding pusher and cryogenically layered deuterium-tritium implosions on the NIF

For the first time, quantitative measurements of collective fuel velocities in Inertial Confinement Fusion implosions at the National Ignition Facility are reported. Velocities along the line-of-sight (LOS) of the Magnetic Recoil neutron Spectrometer (MRS), positioned close to the equator (73 Degree-Sign -324 Degree-Sign ), were inferred from the measured mean energy of the deuterium-tritium (DT)-primary neutron peak. Substantial mean energy shifts up to 113 {+-} 16 keV were observed in DT gas-filled exploding-pusher implosions, driven in a polar-direct drive configuration, which corresponds to bulk fuel velocities up to 210 {+-} 30 km/s. In contrast, only marginal bulk fuel velocities along the MRS LOS were observed in cryogenically layered DT implosions. Integrated analysis of data from a large number of cryogenically layered implosions has recently identified a deficit in achieved hot-spot energy of {approx}3 kJ for these implosions [C. Cerjan et al., Phys. Plasmas (2013)]. One hypothesis that could explain this missing energy is a collective, directional fuel velocity of {approx}190 km/s. As only marginal bulk fuel velocities are observed in the MRS data, this might indicate that turbulent or radial flows would be a likely explanation for the missing energy. However, a directional velocity close to perpendicular to the MRS LOS cannot be ruled out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a deep learning based automated data analysis for step-filter x-ray spectrometers in support of high-repetition rate short-pulse laser-driven acceleration experiments

We present a deep learning based framework for real-time analysis of a differential filter based x-ray spectrometer that is common on short-pulse laser experiments. The analysis framework was trained with a large repository of synthetic data to retrieve key experimental metrics, such as slope temperature. With traditional analysis methods, these quantities would have to be extracted from data using a time-intensive and manual analysis. Furthermore, this framework was developed for a specific diagnostic, but may be applicable to a wide variety of diagnostics common to laser experiments and thus will be especially crucial to the development of high-repetition rate (HRR) diagnostics for HRR laser systems that are coming online.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-406: Use of TrueBeam Developer Mode and API to Increase the Efficiency and Accuracy of Commissioning Measurements for the Varian EDGE Stereotactic Linac

Purpose: The Varian EDGE machine is a new stereotactic platform, combining Calypso and VisionRT localization systems with a stereotactic linac. The system includes TrueBeam DeveloperMode, making possible the use of XML-scripting for automation of linac-related tasks. This study details the use of DeveloperMode to automate commissioning tasks for Varian EDGE, thereby improving efficiency and measurement consistency. Methods: XML-scripting was used for various commissioning tasks,including couch model verification,beam-scanning,and isocenter verification. For couch measurements, point measurements were acquired for several field sizes (2×2,4×4,10×10cm{sup 2}) at 42 gantry angles for two couch-models. Measurements were acquired with variations in couch position(rails in/out,couch shifted in each of motion axes) compared to treatment planning system(TPS)-calculated values,which were logged automatically through advanced planning interface(API) scripting functionality. For beam scanning, XML-scripts were used to create custom MLC-apertures. For isocenter verification, XML-scripts were used to automate various Winston-Lutz-type tests. Results: For couch measurements, the time required for each set of angles was approximately 9 minutes. Without scripting, each set required approximately 12 minutes. Automated measurements required only one physicist, while manual measurements required at least two physicists to handle linac positions/beams and data recording. MLC apertures were generated outside of the TPS,and with the .xml file format, double-checking without use of TPS/operator console was possible. Similar time efficiency gains were found for isocenter verification measurements Conclusion: The use of XML scripting in TrueBeam DeveloperMode allows for efficient and accurate data acquisition during commissioning. The efficiency improvement is most pronounced for iterative measurements, exemplified by the time savings for couch modeling measurements(approximately 10 hours). The scripting also allowed for creation of the files in advance without requiring access to TPS. The API scripting functionality enabled efficient creation/mining of TPS data. Finally, automation reduces the potential for human error in entering linac values at the machine console,and the script provides a log of measurements acquired for each session. This research was supported in part by a grant from Varian Medical Systems, Palo Alto, CA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A micron resolution optical scanner for characterization of silicon detectors

The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2.3.3.404 - National Lab and University Collaboration for MHK Instrumentation and Data Processing Tools

Field and laboratory validation, testing, demonstration, and operation are critical steps for increasing the technology readiness level of marine energy (ME) converters because they provide high-quality testing and performance data that are critical information used to feed all aspects of technology development. This project, in partnership with industry, enables the marine and hydrokinetic energy (MHK) community to reliably and efficiently collect, process, manage, and share quality data by facilitating access to and development of instrumentation, guidelines and data processing/QA tools. Under this project, open-source data processing code (MHKiT) and tools (ME Data Pipeline, MRE Code Hub, PRIMRE Code Catalog), instrumentation (loads measurements), data acquisition systems (miniDAQ), and measurement guidance tools (Telesto, high EMI guidance) were developed to facilitate the collection and processing of quality laboratory and field data. Overall, this project is intended to improve the quality of the data collected during laboratory and field demonstration projects by standardizing the collection and processing techniques, as well as by improving access to instrumentation, code, and measurement guidance. Quality data will, in turn, lead to improved knowledge capture following ME device testing.

data processing↗