Search NASA⌕ Search

SEARCH · Search NASA

Results for “additional protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Caveats and limitations of plate reader-based high-throughput kinetic measurements of intracellular calcium levels

Calcium plays a crucial role in virtually all cellular processes, including neurotransmission. The intracellular Ca{sup 2+} concentration ([Ca{sup 2+}]{sub i}) is therefore an important readout in neurotoxicological and neuropharmacological studies. Consequently, there is an increasing demand for high-throughput measurements of [Ca{sup 2+}]{sub i}, e.g. using multi-well microplate readers, in hazard characterization, human risk assessment and drug development. However, changes in [Ca{sup 2+}]{sub i} are highly dynamic, thereby creating challenges for high-throughput measurements. Nonetheless, several protocols are now available for real-time kinetic measurement of [Ca{sup 2+}]{sub i} in plate reader systems, though the results of such plate reader-based measurements have been questioned. In view of the increasing use of plate reader systems for measurements of [Ca{sup 2+}]{sub i} a careful evaluation of current technologies is warranted. We therefore performed an extensive set of experiments, using two cell lines (PC12 and B35) and two fluorescent calcium-sensitive dyes (Fluo-4 and Fura-2), for comparison of a linear plate reader system with single cell fluorescence microscopy. Our data demonstrate that the use of plate reader systems for high-throughput real-time kinetic measurements of [Ca{sup 2+}]{sub i} is associated with many pitfalls and limitations, including erroneous sustained increases in fluorescence, limited sensitivity and lack of single cell resolution. Additionally, our data demonstrate that probenecid, which is often used to prevent dye leakage, effectively inhibits the depolarization-evoked increase in [Ca{sup 2+}]{sub i}. Overall, the data indicate that the use of current plate reader-based strategies for high-throughput real-time kinetic measurements of [Ca{sup 2+}]{sub i} is associated with caveats and limitations that require further investigation. - Research Highlights: > The use of plate readers for high-throughput screening of intracellular Ca{sup 2+} is associated with many pitfalls and limitations. > Single cell fluorescent microscopy is recommended for measurements of intracellular Ca{sup 2+}. > Dual-wavelength dyes (Fura-2) are preferred over single-wavelength dyes (Fluo-4) for measurements of intracellular Ca{sup 2+}. > Probenecid prevents dye leakage but abolishes depolarization-evoked Ca{sup 2+} influx, severely hampering measurements of Ca{sup 2+}. > In general, care should be taken when interpreting data from high-throughput kinetic measurements.

60 APPLIED LIFE SCIENCES↗

Effect of water on nanomechanics of bone is different between tension and compression

Water, an important constituent in bone, resides in different compartments in bone matrix and may impose significant effects on its bulk mechanical properties. However, a clear understanding of the mechanistic role of water in toughening bone is yet to emerge. To address this issue, this study used a progressive loading protocol, coupled with measurements of in situ mineral and collagen fibril deformations using synchrotron X-ray diffraction techniques. Using this unique approach, the contribution of water to the ultrastructural behavior of bone was examined by testing bone specimens in different loading modes (tension and compression) and hydration states (wet and dehydrated). The results indicated that the effect of water on the mechanical behavior of mineral and collagen phases at the ultrastructural level was loading mode dependent and correlated with the bulk behavior of bone. Tensile loading elicited a transitional drop followed by an increase in load bearing by the mineral phase at the ultrastructural level, which was correlated with a strain hardening behavior of bone at the bulk level. Compression loading caused a continuous loss of load bearing by the mineral phase, which was reflected at the bulk level as a strain softening behavior. In addition, viscous strain relaxation and pre-strain reduction were observed in the mineral phase in the presence of water. Taken together, the results of this study suggest that water dictates the bulk behavior of bone by altering the interaction between mineral crystals and their surrounding matrix.

Samuel, Jitin (ORCID:0000000195203350)↗

Expression, purification, characterization and crystallization of non- and phosphorylated states of JAK2 and JAK3 kinase domain

Janus-associated kinases (JAKs) play critical roles in cytokine signaling, and have emerged as viable therapeutic targets in inflammation and oncology related diseases. To date, targeting JAK proteins with highly selective inhibitor compounds have remained elusive. We have expressed the active kinase domains for both JAK2 and JAK3 and devised purification protocols to resolve the non-, mono- (Y1007) and diphosphorylated (Y1007 and Y1008) states of JAK2 and non- and monophosphorylated states of JAK3 (Y980). An optimal purified protein yield of 20, 29 and 69 mg per 20 L cell culture was obtained for the three JAK2 forms, respectively, and 12.2 and 2.3 mg per 10 L fermentation for the two JAK3 forms allowing detailed biochemical and biophysical studies. To monitor the purification process we developed a novel HPLC activity assay where a sequential order of phosphorylation was observed whereby the first tyrosine residue was completely phosphorylated prior to phosphorylation of the tandem tyrosine residue. A Caliper-based microfluidics assay was used to determine the kinetic parameters (K{sub m} and k{sub cat}) for each phosphorylated state, showing that monophosphorylated (Y1007) JAK2 enzyme activity increased 9-fold over that of the nonphosphorylated species, and increased an additional 6-fold for the diphosphorylated (Y1007/Y1008) species, while phosphorylation of JAK3 resulted in a negligible increase in activity. Moreover, crystal structures have been generated for each isolated state of JAK2 and JAK3 with resolutions better than 2.4 {angstrom}. The generation of these reagents has enabled kinetic and structural characterization to inform the design of potent and selective inhibitors of the JAK family.

59 BASIC BIOLOGICAL SCIENCES↗

SPRUCE Vegetation Phenology in Experimental Plots from PhenoCam Imagery, 2015-2024

This data set consists of PhenoCam data from the SPRUCE experiment from the beginning of whole ecosystem warming (Hanson et al. 2017) in August 2015 through March 31 of 2025 (2015-08-24 to 2025-03-31), with start- and end-of-season phenological transition dates derived through the end of autumn 2024. Digital cameras, or phenocams, installed in each SPRUCE enclosure track seasonal variation in vegetation “greenness”, a proxy for vegetation phenology and associated physiological activity. Three separate regions of interest (ROIs) were defined for each camera field of view, corresponding to different vegetation types and demarcating (1) Picea trees (vegetation type EN, for evergreen needleleaf); (2) Larix trees (vegetation type DN, for deciduous needleleaf); and (3) the mixed shrub layer (vegetation type SH). This data set consists of three sets of data files: (1) 3-day summary product files: One file for each camera and each ROI (i.e. vegetation type), characterizing vegetation color at a 3-day time step. • Contains 36 files in *.csv format inside a compressed (*.zip) file. (2) Transition date file: Estimates “greenness rising” (spring) and “greenness falling” (autumn) transition dates derived from the smoothed daily green chromatic coordinate (GCC) values, for each camera and each ROI (i.e., vegetation type). • Contains one file in *.csv format. (3) Snow flag files: Indicate days with snow on trees or snow on ground for each experimental enclosure. • Contains two files in *.csv format, one for snow on trees and one for snow on ground. This data set consists of two sets of companion files: (1) Accompanying HTML files show the 90th quantiles of the mean GCC plotted together with transition dates for each vegetation type and plot. • Contains three files in HTML format, one for each vegetation type. • One additional file in HTML format with the transition dates plotted for each vegetation type, by year. (2) R files for processing PhenoCam files and flags. • Contains five files in R file(*.R) format and the components of the phenocamr package (Version 1.1.4) used for calculating transition dates for 2015-2024. These are contained in a compressed (*.zip) file. User Note: All imagery is posted in near-real time to the PhenoCam Project web page (https://phenocam.nau.edu), where it is publicly available. Scroll to “spruce” in the Gallery or link directly to the 29 SPRUCE cameras at https://tinyurl.com/sprucecams. This data set is based on the complete camera record from SPRUCE and supersedes all previously released PhenoCam datasets (see Related Data Sets). The estimated transition dates for previously released datasets may differ slightly (in most cases, by ±3 days or less), because following standard PhenoCam processing protocols (Richardson et al. 2018, Scientific Data), smoothing and interpolation, outlier removal, and transition date estimation are always conducted using the full data record.

54 ENVIRONMENTAL SCIENCES↗

Validation of Fitness for Duty Standards Using Pre- and Post-Flight Capsule Egress and Suited Functional Performance Tasks in Simulated Reduced Gravity

The transition between gravity environments will involve one of the most complex, high-risk phases of any mission. For example, the reduced functional capacity caused by physiological deconditioning adaptations in microgravity coupled with the stressors of re-entry into partial gravity environments will increase risks to crew, even with rigorous adherence to inflight countermeasures. Quantification of the astronauts’ post-landing functional performance is necessary to design ConOps for exploration missions. Specifically, these two high-risk scenarios may be required to be performed soon after gravity transitions: • Nominal and/or emergency unassisted capsule egress task after return to Earth • Planetary extravehicular activity (EVA) soon after landing on Mars or the Moon This study is broken down into two phases. Phase 1: A feasibility study that will assess the overall feasibility and demonstrate the capability to do these tasks shortly after landing. Phase 2: the full Egress Fitness study, which is part of the CIPHER complement. This study uses a task-based approach to characterize functional performance of these high-risk scenarios in long-duration ISS crewmembers before flight and shortly after return to Earth. Prior to any testing, each astronaut subject completes a suit fit check to ensure adequate sizing and a mobility assessment to confirm completion of the EVA tasks. Pilot Egress Fitness pre-flight and post-flight testing includes an Earth-based emergency egress out of a functional capsule mockup and a short Mars gravity EVA simulation including suit donning, hatch egress, ladder descent, task board cable operations, baggage transfer over sand/rocky regolith, alignment with a rear entry port, and suit egress. Pre-flight testing will occur at any time point prior to flight. Post-flight assessment is much more critical with the capsule egress test that will occur 1–4 hours after landing and the planetary EVA approximately 18–36 hours after landing. The CIPHER study will incorporate additional pre-flight sessions, longer EVA tasks that include traverse and geology sampling, and post-flight sessions on R+1, 4, and 8 to characterize the timeframe of recovery. Data collected for both tasks include task completion time, photo, and video. The EVA portion also includes collection of metabolic and heart rate. Pilot Egress Fitness study has completed both baseline and post-flight testing on four astronaut subjects, with all four able to complete post-flight EVA testing and three able to complete postflight capsule egress testing. Preliminary results observe individual physiological variations, which were to be expected but also suggest the need to carefully track the timeline from undock to landing to testing. Furthermore, some task performance instructions and equipment may need to be adjusted to ensure results are primarily physiological. These and other lessons learned will be addressed with minor protocol changes in the full CIPHER Egress Fitness study.

J R Norcross↗

SU-E-I-94: Automated Image Quality Assessment of Radiographic Systems Using An Anthropomorphic Phantom

Purpose: In a large, academic medical center, consistent radiographic imaging performance is difficult to routinely monitor and maintain, especially for a fleet consisting of multiple vendors, models, software versions, and numerous imaging protocols. Thus, an automated image quality control methodology has been implemented using routine image quality assessment with a physical, stylized anthropomorphic chest phantom. Methods: The “Duke” Phantom (Digital Phantom 07-646, Supertech, Elkhart, IN) was imaged twice on each of 13 radiographic units from a variety of vendors at 13 primary care clinics. The first acquisition used the clinical PA chest protocol to acquire the post-processed “FOR PRESENTATION” image. The second image was acquired without an antiscatter grid followed by collection of the “FOR PROCESSING” image. Manual CNR measurements were made from the largest and thickest contrast-detail inserts in the lung, heart, and abdominal regions of the phantom in each image. An automated image registration algorithm was used to estimate the CNR of the same insert using similar ROIs. Automated measurements were then compared to the manual measurements. Results: Automatic and manual CNR measurements obtained from “FOR PRESENTATION” images had average percent differences of 0.42%±5.18%, −3.44%±4.85%, and 1.04%±3.15% in the lung, heart, and abdominal regions, respectively; measurements obtained from “FOR PROCESSING” images had average percent differences of -0.63%±6.66%, −0.97%±3.92%, and −0.53%±4.18%, respectively. The maximum absolute difference in CNR was 15.78%, 10.89%, and 8.73% in the respective regions. In addition to CNR assessment of the largest and thickest contrast-detail inserts, the automated method also provided CNR estimates for all 75 contrast-detail inserts in each phantom image. Conclusion: Automated analysis of a radiographic phantom has been shown to be a fast, robust, and objective means for assessing radiographic image quality. The method reduces the burden of manual measurements and provides a means by which to monitor and compare radiographic system performance.

60 APPLIED LIFE SCIENCES↗

Deactivation trends of Pd/SSZ-13 under the simultaneous presence of NO, CO, hydrocarbons and water for passive NO x adsorption

Pd-functionalized chabazite (Pd/SSZ-13) was evaluated for passive NO x adsorption (PNA) using low temperature combustion with diesel (LTC-D) reaction feed of the “United States Driving Research and Innovation for Vehicle efficiency and Energy sustainability” (U.S.DRIVE) protocol. Notably as per the protocol conditions, 12% O 2 + 6% CO 2 + 6% H 2 O was flown in all cases. NO-uptake studies in the presence of the LTC-D feed showed a systematic decline with (NO:Pd)molar changing from 0.5 to 0.4 after 10 trials. Control experiments showed more pronounced decline for NO + CO case, with appreciable intial (NO:Pd)molar value of 0.4 yet comparable-to-the-LTC-D-feed decline after 8 trials. CO-induced particle formation and larger extent of particle sintering was also evident from TEM analysis. Other controls did not exhibit trial-dependent deactivation as(NO:Pd)molar values were constant, at 0.3, 0.2, 0.5 and 0.2 for the NO, NO+H 2 , NO + unsaturated hydrocarbon (C 2 H 4 , C 3 H 6 ) and NO + saturated HC (C 3 H 8 , C 10 H 22 ) feeds respectively. In addition to these quantitative differences, desorption behaviors are qualitatively different. While only one major desorption event is observed for the full LTC-D, NO+ CO and NO+ unsaturated HC-controls, desorption occurs in two distinct stages for NO, NO + saturated HCs and initial-NO+H 2 trials. This arises due to inherent differences in Pd sites while exposed to these chemically distinct feeds. Furthermore, presence of reducing agents such as CO and unsaturated HCs in the feed result in almost complete elimination of lower, sub-200 °C desorption peak. The higher temperature desorption peaks, at > 300 °C is associated with NO strongly bound to ionic Pd sites and are prevalent under reducing conditions. Using DRIFTS also, three complexes leading to PNA are assigned, [O = N–Pd 2 +(OH)–Z], [O = N–Pd 2 +(Z2)] and [O = N–Pd 2 +(H 2 O)y–Z] with the latter being clearly observed upon water exposure. Pd/SSZ-13 showed higher hydrocarbon trapping than the SSZ-13 counterpart.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reinventing Image Detective: An Evidence-Based Approach to Citizen Science Online

Usability studies demonstrate that web users are notoriously impatient, spending as little as 15 seconds on a home page. How do you get users to stay long enough to understand a citizen science project? How do you get users to complete complex citizen science tasks online? Image Detective, a citizen science project originally developed by scientists and science engagement specialists at the NASA Johnson Space center to engage the public in the analysis of images taken from space by astronauts to help enhance NASA's online database of astronaut imagery, partnered with the CosmoQuest citizen science platform to modernize, offering new and improved options for participation in Image Detective. The challenge: to create a web interface that builds users' skills and knowledge, creating engagement while learning complex concepts essential to the accurate completion of tasks. The project team turned to usability testing for an objective understanding of how users perceived Image Detective and the steps required to complete required tasks. A group of six users was recruited online for unmoderated and initial testing. The users followed a think-aloud protocol while attempting tasks, and were recorded on video and audio. The usability test examined users' perception of four broad areas: the purpose of and context for Image Detective; the steps required to successfully complete the analysis (differentiating images of Earth's surface from those showing outer space and identifying common surface features); locating the image center point on a map of Earth; and finally, naming geographic locations or natural events seen in the image. Usability test findings demonstrated that the following best practices can increase participation in Image Detective and can be applied to the successful implementation of any citizen science project: (1) Concise explanation of the project, its context, and its purpose; (2) Including a mention of the funding agency (in this case, NASA); (3) A preview of the specific tasks required of participants; (4) A dedicated user interface for the actual citizen science interaction. In addition, testing revealed that users may require additional context when a task is complex, difficult, or unusual (locating a specific image and its center point on a map of Earth). Video evidence will be made available with this presentation.

Romano, Cia↗

Changes in Oculomotor Behavior and PVT Reaction Time During One Night of Sleep Deprivation

INTRODUCTION: The Psychomotor Vigilance Test (PVT) is a widely used objective measure of sustained attention, alertness, and fatigue. Previous studies consistently show that prolonged wakefulness and disrupted sleep patterns lead to increased lapses of attention and slower reaction times. These findings have critical implications for various professions, including healthcare, aviation, transportation safety, and spaceflight. In this study, we employed linear mixed models (LMM) to investigate hourly-measured 5-minute PVT reaction times during one night of total sleep deprivation. Our goal was to characterize the contribution of homeostatic sleep pressure (time awake) and circadian phase (salivary melatonin levels) on the dynamics of PVT reaction time. MATERIALS & METHODS: Data from twelve human participants were used in the analysis. Participants were healthy non-smokers, aged 18 and 40, with normal sleep habits defined as Pittsburg Sleep Quality Index scores < 5, and Morningness – Eveningness Questionnaire scores > 42 and < 58, respectively. Participants followed a constant-routine protocol and arrived at the NASA sleep laboratory approximately 1 to 2 hours after their habitual waking time. Tympanic temperature was measured every 30 min to provide a real-time estimate of circadian phase. Participants were required to stay awake throughout the laboratory experiment, which continued until their tympanic temperature had returned to baseline levels. This approach ensured that we could capture each participant's circadian trough and recovery, typically occurring between 24 and 26 hours after waking. The PVT and saliva melatonin were measured every hour, starting approximately from 3 hours after awakening. More information about the measurement protocol can be found in the publication by Stone et al. We used PVT reaction times between 100 and 10000 ms to calculate Reciprocal Reaction Times (RRTs). LMM models were employed to assess the contribution of time awake and saliva melatonin levels on changes in RRTs. Two models were created: the first model treated time awake as a fixed effect and the second model considered both the salivary melatonin level and time awake as fixed effects. Participants were included as a random effect in both models. We compared the models using an Analysis of Variance (ANOVA). The models were computed using the 'lmer' function from the 'lme4' package in R, and LMM p-values were determined using Satterthwaite's method. RESULTS: We found that time awake had a statistically significant effect on PVT RRTs during one night of sleep deprivation [χ2 = 2132.4, df = 1, p < 0.001]. In addition, the model including both saliva melatonin levels and time awake was statistically significantly better than one that uses just time awake [χ2 = 17.4, df = 1, p < 0.001]. DISCUSSION & CONCLUSION: As expected, these preliminary results suggest that the time awake and circadian phase each contribute to performance reductions as measured by the PVT. Future analyses will explore the contributions of other factors to the model.

sleep deprivation↗

Performance of three-dimensional printed nasopharyngeal swabs for COVID-19 testing

At the start of the COVID-19 pandemic, the US faced nationwide shortages of nasopharyngeal swabs due to both overwhelmed supply chains and an increase in demand. To address this shortfall, multiple 3D printed swabs were ultimately produced and sold for COVID-19 testing. In this work, we present a framework for mechanical and functional bench-testing of nasopharyngeal swabs using standard and widely available material testing equipment. Using this framework, we offer a comprehensive, quantitative comparison of the 3D printed swabs to benchmark their performance against traditional flocked swabs. The test protocols were designed to emulate the clinical use of the nasopharyngeal swabs and to evaluate potential failure modes. Overall, the 3D printed swabs performed comparably to, or outperformed, the traditional swabs in all mechanical tests. While traditional swabs outperformed some of the new 3D printed swabs in terms of sample uptake and retention, similar amounts of RNA were recovered from both 3D printed and traditional swabs.

3D printing↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward a clinical application of ex situ boron neutron capture therapy for lung tumors at the RA-3 reactor in Argentina

Purpose: Many types of lung tumors have a very poor prognosis due to their spread in the whole organ volume. The fact that boron neutron capture therapy (BNCT) would allow for selective targeting of all the nodules regardless of their position, prompted a preclinical feasibility study of ex situ BNCT at the thermal neutron facility of RA-3 reactor in the province of Buenos Aires, Argentina. (L)-4p-dihydroxy-borylphenylalanine fructose complex (BPA-F) biodistribution studies in an adult sheep model and computational dosimetry for a human explanted lung were performed to evaluate the feasibility and the therapeutic potential of ex situ BNCT. Methods: Two kinds of boron biodistribution studies were carried out in the healthy sheep: a set of pharmacokinetic studies without lung excision, and a set that consisted of evaluation of boron concentration in the explanted and perfused lung. In order to assess the feasibility of the clinical application of ex situ BNCT at RA-3, a case of multiple lung metastases was analyzed. A detailed computational representation of the geometry of the lung was built based on a real collapsed human lung. Dosimetric calculations and dose limiting considerations were based on the experimental results from the adult sheep, and on the most suitable information published in the literature. In addition, a workable treatment plan was considered to assess the clinical application in a realistic scenario. Results: Concentration-time profiles for the normal sheep showed that the boron kinetics in blood, lung, and skin would adequately represent the boron behavior and absolute uptake expected in human tissues. Results strongly suggest that the distribution of the boron compound is spatially homogeneous in the lung. A constant lung-to-blood ratio of 1.3 ± 0.1 was observed from 80 min after the end of BPA-F infusion. The fact that this ratio remains constant during time would allow the blood boron concentration to be used as a surrogate and indirect quantification of the estimated value in the explanted healthy lung. The proposed preclinical animal model allowed for the study of the explanted lung. As expected, the boron concentration values fell as a result of the application of the preservation protocol required to preserve the lung function. The distribution of the boron concentration retention factor was obtained for healthy lung, with a mean value of 0.46 ± 0.14 consistent with that reported for metastatic colon carcinoma model in rat perfused lung. Considering the human lung model and suitable tumor control probability for lung cancer, a promising average fraction of controlled lesions higher than 85% was obtained even for a low tumor-to-normal boron concentration ratio of 2. Conclusions: This work reports for the first time data supporting the validity of the ovine model as an adequate human surrogate in terms of boron kinetics and uptake in clinically relevant tissues. Collectively, the results and analysis presented would strongly suggest that ex situ whole lung BNCT irradiation is a feasible and highly promising technique that could greatly contribute to the treatment of metastatic lung disease in those patients without extrapulmonary spread, increasing not only the expected overall survival but also the resulting quality of life.

60 APPLIED LIFE SCIENCES↗

LIGHT-bgcArgo-1.0: using synthetic float capabilities in E3SMv2 to assess spatiotemporal variability in ocean physics and biogeochemistry

Since their advent over 2 decades ago, autonomous Argo floats have revolutionized the field of oceanography, and, more recently, the addition of biogeochemical and biological sensors to these floats has greatly improved our understanding of carbon, nutrient, and oxygen cycling in the ocean. While Argo floats offer unprecedented horizontal, vertical, and temporal coverage of the global ocean, uncertainties remain about whether Argo sampling frequency and density capture the true spatiotemporal variability in physical, biogeochemical, and biological properties. As the true distributions of, e.g., temperature or oxygen are unknown, these uncertainties remain difficult to address with Argo floats alone. Numerical models with synthetic observing systems offer one potential avenue to address these uncertainties. Here, we implement synthetic biogeochemical Argo floats into the Energy Exascale Earth System Model version 2 (E3SMv2), which build on the Lagrangian In Situ Global High-Performance Particle Tracking (LIGHT) module in E3SMv2 (E3SMv2-LIGHT-bgcArgo-1.0). Since the synthetic floats sample the model fields at model run time, the end user defines the sampling protocol ahead of any model simulation, including the number and distribution of synthetic floats to be deployed, their sampling frequency, and the prognostic or diagnostic model fields to be sampled. Using a 6-year proof-of-concept simulation, we illustrate the utility of the synthetic floats in different case studies. In particular, we quantify the impact of (i) sampling density on the float-derived detection of deep-ocean change in temperature or oxygen and on float-derived estimates of phytoplankton phenology, (ii) sampling frequency and sea-ice cover on float trajectory lengths and hence float-derived estimates of current velocities, and (iii) short-term variability in ecosystem stressors on estimates of their seasonal variability.

54 ENVIRONMENTAL SCIENCES↗

Making tomorrow's mistakes today: Evolutionary prototyping for risk reduction and shorter development time

In the early days of JPL's solar system exploration, each spacecraft mission required its own dedicated data system with all software applications written in the mainframe's native assembly language. Although these early telemetry processing systems were a triumph of engineering in their day, since that time the computer industry has advanced to the point where it is now advantageous to replace these systems with more modern technology. The Space Flight Operations Center (SFOC) Prototype group was established in 1985 as a workstation and software laboratory. The charter of the lab was to determine if it was possible to construct a multimission telemetry processing system using commercial, off-the-shelf computers that communicated via networks. The staff of the lab mirrored that of a typical skunk works operation -- a small, multi-disciplinary team with a great deal of autonomy that could get complex tasks done quickly. In an effort to determine which approaches would be useful, the prototype group experimented with all types of operating systems, inter-process communication mechanisms, network protocols, packet size parameters. Out of that pioneering work came the confidence that a multi-mission telemetry processing system could be built using high-level languages running in a heterogeneous, networked workstation environment. Experience revealed that the operating systems on all nodes should be similar (i.e., all VMS or all PC-DOS or all UNIX), and that a unique Data Transport Subsystem tool needed to be built to address the incompatibilities of network standards, byte ordering, and socket buffering. The advantages of building a telemetry processing system based on emerging industry standards were numerous: by employing these standards, we would no longer be locked into a single vendor. When new technology came to market which offered ten times the performance at one eighth the cost, it would be possible to attach the new machine to the network, re-compile the application code, and run. In addition, we would no longer be plagued with lack of manufacturer support when we encountered obscure bugs. And maybe, hopefully, the eternal elusive goal of software portability across different vendors' platforms would finally be available. Some highlights of our prototyping efforts are described.

Friedman, Gary↗

Preparation of the NASA Air Quality Monitor for a U.S. Navy Submarine Sea Trial

For the past 4 years, the Air Quality Monitor (AQM) has been the operational instrument for measuring trace volatile organic compounds on the International Space Station (ISS). The key components of the AQM are the inlet preconcentrator, the gas chromatograph (GC), and the differential mobility spectrometer. Onboard the ISS are two AQMs with different GC columns that detect and quantify 22 compounds. The AQM data contributes valuable information to the assessment of air quality aboard ISS for each crew increment. The US Navy is looking to update its submarine air monitoring suite of instruments and the success of the AQM on ISS has led to a jointly planned submarine sea trial of a NASA AQM. In addition to the AQM, the Navy is also interested in the Multi-Gas Monitor (MGM), which measures major constituent gases (oxygen, carbon dioxide, water vapor, and ammonia). A separate paper will present the MGM sea trial preparation and the analysis of most recent ISS data. A prototype AQM, which is virtually identical to the operational AQM, has been readied for the sea trial. Only one AQM will be deployed during the sea trial, but this is sufficient for NASA purposes and to detect the compounds of interest to the US Navy for this trial. The data from the sea trial will be compared to data from archival samples collected before, during, and after the trial period. This paper will start with a brief history of past collaborations between NASA and the U.S. and U.K. navies for trials of air monitoring equipment. An overview of the AQM technology and protocols for the submarine trial will be presented. The majority of the presentation will focus on the AQM preparation and a summary of available data from the trial.

Limero, Thomas↗

Degradation of transparent conductive oxides: Interfacial engineering and mechanistic insights

Transparent conductive oxides (TCOs) are a known failure mode in a variety of thin film photovoltaic (PV) devices, through mechanisms such as resistivity increase and delamination. Degradation science studies of these materials, as well as most PV systems, have primarily utilized industry standard qualification protocols, which are not designed to be used as lifetime prediction tests. Here, this work applies a data science approach to this engineering challenge, utilizing commercially available TCOs and subjecting them to an array of stressors, including environmental and material stressors. Optical, electrical and surface sensitive TCO property metrics were monitored and analyzed en mass. Different degradation mechanisms and modes were observed when different stressor combinations were applied; TCO surfaces are sensitive to the proportion of water and light in an exposure, yellowing of the TCO only occurs when humidity and UV light are combined, and PEDOT:PSS (poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate)) application results in hazing and roughening of aluminum-doped zinc oxide (AZO). Using multi-variate analytics and plotting critical material properties against one another in a mechanistic plot, trade-offs between properties and the activation of different degradation mechanisms become readily apparent. In addition to a survey of failure modes of TCOs, a possible solution to the degradation of AZO was examined: the application of an organofunctional silane layer. The application of a thin APTES (3-aminopropyltriethoxysilane) film nearly eliminated the observed edge effects and greatly reduced the resistivity increase caused by damp heat exposure of AZO.

14 SOLAR ENERGY↗

Biochemical Conversion of Herbaceous Biomass to Renewable Diesel: Net Greenhouse Gas and Air Pollutant Trade-offs

This study examines greenhouse gas (GHG) and criteria air pollutant (CAP) emissions trade-offs for renewable diesel across 12 scenarios, involving different biochemical conversion designs, biorefinery scales, and feedstocks. A conventional design uses lignin for on-site heat and power, which exports excess power to the grid. An alternative design exports lignin pellets, offsetting other pellet production methods but requiring grid electricity to meet biorefinery power demands. Net emissions were quantified in Iowa and Georgia, selected considering feedstock availability, coproduct displacement, and regional power grids, assuming grid-exported power avoids coal or low-carbon electricity. Results for the conventional design remained consistent across the electricity displacement scenarios. When comparing lignin utilization strategies, pelletizing lignin reduces sulfur dioxide, carbon monoxide, nitrogen oxides, and volatile organic compounds (net emissions –0.66 mg MJ –1 , 25 mg MJ –1 , 25 mg MJ –1 , 7.8 mg MJ –1 , respectively). However, lignin pelletization increases net particulate matter (fine and coarse) and ammonia (net emissions of 4.7 mg MJ –1 , 13 mg MJ –1 , and 0.26 mg MJ –1 , respectively), alongside indirect GHG emissions due to grid electricity dependence. Additionally, processing 2000 tonnes corn stover daily minimizes emissions for both designs. Only lignin pelletization with renewable electricity and additional particulate matter and ammonia controls reduces all CAP and GHG emissions simultaneously.

09 BIOMASS FUELS↗

TH-CD-202-06: A Method for Characterizing and Validating Dynamic Lung Density Change During Quiet Respiration

Purpose: To obtain a functional relationship that calibrates the lung tissue density change under free breathing conditions through correlating Jacobian values to the Hounsfield units. Methods: Free-breathing lung computed tomography images were acquired using a fast helical CT protocol, where 25 scans were acquired per patient. Using a state-of-the-art deformable registration algorithm, a set of the deformation vector fields (DVF) was generated to provide spatial mapping from the reference image geometry to the other free-breathing scans. These DVFs were used to generate Jacobian maps, which estimate voxelwise volume change. Subsequently, the set of 25 corresponding Jacobian and voxel intensity in Hounsfield units (HU) were collected and linear regression was performed based on the mass conservation relationship to correlate the volume change to density change. Based on the resulting fitting coefficients, the tissues were classified into parenchymal (Type I), vascular (Type II), and soft tissue (Type III) types. These coefficients modeled the voxelwise density variation during quiet breathing. The accuracy of the proposed method was assessed using mean absolute difference in HU between the CT scan intensities and the model predicted values. In addition, validation experiments employing a leave-five-out method were performed to evaluate the model accuracy. Results: The computed mean model errors were 23.30±9.54 HU, 29.31±10.67 HU, and 35.56±20.56 HU, respectively, for regions I, II, and III, respectively. The cross validation experiments averaged over 100 trials had mean errors of 30.02 ± 1.67 HU over the entire lung. These mean values were comparable with the estimated CT image background noise. Conclusion: The reported validation experiment statistics confirmed the lung density modeling during free breathing. The proposed technique was general and could be applied to a wide range of problem scenarios where accurate dynamic lung density information is needed. This work was supported in part by NIH R01 CA0096679.

60 APPLIED LIFE SCIENCES↗