Search NASA⌕ Search

SEARCH · Search NASA

Results for “application”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

SU-F-P-58: Squamous Cell and Basal Cell Carcinoma of the Skin Treated with a Freiburg Flap Applicator

Purpose: To treat squamous cell and basal cell carcinoma of the skin with the Freiburg flap applicator using a high dose rate modality of an Elekta Flexitron or MicroSelectron for radiation delivery by compensating the dose deviation resulting from the incomplete scatter environment. Methods: Patients were selected to have lesions greater than or equal to 2cm. A mask might be needed depending on special locations. The lesions on the eyelid and face presented in this research were, however, treated without a mask. Cutting the flap into a shape conformal to the target and attaching it to the mask were used in order to make the treatment reproducible. Patients were scanned with a Philips Big Bore Brilliant CT. A 1cm margin was added to the lesion. An Elekta Oncentra Brachy treatment planning system ver. 4.3 was used for treatment planning. 40 Gy in 10 or 8 fractions was prescribed to the 1cm depth. The Freiburg flap was aligned and verified by CT scanning prior to treatment. Results: Three patients with squamous cell and basal cell carcinoma of the skin were treated with the Freiburg flap applicator. Lesion sizes ranged from 2cm to 6 cm in a maximum dimension. With treatment planning, we made a dose correction for compensating the dose deviation resulting from the incomplete scatter environment of the flap applicators exposed to air. The flap was also covered by a 4cm bolus in order to obtain more back scattered radiation during treatment. Six month follow up showed a very good cosmetic result. Conclusion: The Freiburg flap brachytherapy offers a non-invasive skin cancer treatment with a high skin dose delivered to the tumor while a low dose sparing the surrounding health tissue. It is a promising alternative to skin cancer surgery or external beam radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-F-J-87: Impact Of The Dosimetric Consequences From Minimal Displacements Throughout The Treatment Time In APBI With SAVI Applicators

Purpose: To assess the variation in dose received by the organs at risk (OARs) due to inter-fractional motion by SAVI to determine the importance of providing proper immobilization Methods: An analysis of 15 patients treated with SAVI applicators were considered for this study. Treatment planning teams did not see significant changes in their CT scans through scout images and initial treatment plan was used for the entire treatment. These scans, taken before each treatment were imported in to the treatment planning system and were fused together with respective to the applicator, using landmark registration. Dosimetric evaluations were performed. Dose received by skin, ribs and PTV(Planning target volume) respect to the initial treatment plan were measured. Results: Contours of the OARs were not similar with the initial image. Deduction in volumes of PTV and cavity, small deviations in displacements from the applicator to the OARs, difference in doses received by the OARs between treatments were noticed. The maximum, minimum, average doses varied between 10% to 20% 5% to 8% and 15% to 20% in ribs and skin. The 0.1cc doses to OARs showed an average change of 10% of the prescribed dose. PTV was receiving a different dose than the estimated dose Conclusion: The variation in volumes and isodoses related to the OARs, PTV receiving a lesser dose than the prescribed dose indicate that the estimated doses are different from the received dose. This study reveals the urgent need of improving the immobilization methods. Taking a CT scan before each treatment and replanning is helpful to minimize the risk of delivering undesired high doses to the OARs. Patient positioning, motion, respiration, observer differences and time lap between the planning and treating can arise more complications. VacLock, Positioning cushions, Image guided brachytherapy and adjustable registration should be used for further improvements.

60 APPLIED LIFE SCIENCES↗

SU-F-T-30: Comprehensive Dosimetric Characterization of the Novel Direction Modulation Brachytherapy (DMBT) Tandem Applicator Using Monte Carlo Simulations

Purpose: To characterize the dosimetric properties/distributions of the novel proposed direction modulated brachytherapy (DMBT) tandem applicator in combination with 192Ir HDR source, and compare against conventional tandem design, using Monte Carlo simulations. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy, especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles – leading to enhanced dose sculpting capacity through inverse planning. In-water dosimetric parameters for the DMBT and conventional tandems have been calculated for various radial distances away and around the tandems. For the DMBT tandem, the cumulative dose from the 192Ir source occupying 1) one and 2) all six holes in equal dwell times was calculated and normalized to match the dose rate of the open source (in conventional tandem) at 1 cm from the center. This is done to compare and contrast the characteristic dose distributions to that of the isotropic TG43-based 192Ir source. Results: All dose rates were normalized at 1-cm radius from the center of the applicators, containing source(s). The normalized dose rates at 0.5, 3.0, and 5.0-cm radiuses were then 388, 11.3, and 4.1% for conventional tandem, 657, 8.1, and 2.7% for DMBT tandem with the source in one hole at front entrance, and 436, 10.9, and 3.8% for DMBT tandem with the source in all six holes. For the DMBT tandem case with the source in one hole, the backside transmissions were 47, 2.4, and 0.9%, respectively. Conclusion: The DMBT tandem is able to generate closely similar dosimetric characteristics as that of the single-channel conventional tandem if needed (with the source occupying all six holes), at the same time, generate directional radiation profile(s) for favorably enabling 3D dose sculpting capability.

60 APPLIED LIFE SCIENCES↗

SU-F-T-577: Comparison of Small Field Dosimetry Measurements in Fields Shaped with Conical Applicators On Two Different Accelerating Systems

Purpose: To investigate small field dosimetry measurements and associated uncertainties when conical applicators are used to shape treatment fields from two different accelerating systems. Methods: Output factor measurements are made in water in beams from the CyberKnife radiosurgery system, which uses conical applicators to shape fields from a (flattening filter-free) 6 MV beam, and in a 6 MV beam from the Elekta Precise linear accelerator (with flattening filter) with BrainLab external conical applicators fitted to shape the field. The measurements use various detectors: (i) an Exradin A16 ion chamber, (ii) two Exradin W1 plastic scintillation detectors, (iii) a Sun Nuclear Edge diode, and (iv) two PTW microDiamond synthetic diamond detectors. Profiles are used for accurate detector positioning and to specify field size (FWHM). Output factor measurements are corrected with detector specific correction factors taken from the literature where available and/or from Monte Carlo simulations using the EGSnrc code system. Results: Differences in measurements of up to 1.7% are observed with a given detector type in the same beam (i.e., intra-detector variability). Corrected results from different detectors in the same beam (inter-detector differences) show deviations up to 3 %. Combining data for all detectors and comparing results from the two accelerators results in a 5.9% maximum difference for the smallest field sizes (FWHM=5.2–5.6 mm), well outside the combined uncertainties (∼1% for the smallest beams) and/or differences among detectors. This suggests that the FWHM of a measured profile is not a good specifier to compare results from different small fields with the same nominal energy. Conclusion: Large differences in results for both intra-detector variability and inter-detector differences suggest potentially high uncertainties in detector-specific correction factors. Differences between the results measured in circular fields from different accelerating systems provide insight into sources of variability in small field dosimetric measurements reported in the literature.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-201-11: Exploring the Upper Limits of Dose Sculpting Capacity of the Novel Direction Modulated Brachytherapy (DMBT) Tandem Applicator

Purpose: To explore and quantify the upper limits in dose sculpting capacity of the novel direction modulated brachytherapy (DMBT) tandem applicator compared with conventional tandem design for {sup 192}Ir-based HDR planning. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy (IGABT), especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles – leading to enhanced dose sculpting capacity through inverse planning. The external dimensions are identical to that of conventional tandem design to ensure clinical compatibility. To explore the expansive dose sculpting capacity, we constructed a hypothetical circular target with 20-mm radius and positioned the DMBT and conventional tandems at the center. We then incrementally shifted the positions laterally away from the center of up to 15 mm, at 1-mm steps. The in-house coded gradient projection-based inverse planning system was then used to generate inverse optimized plans ensuring identical V100=100% coverage. Conformity index (CI) was calculated for all plans. Results: Overall, the DMBT tandem generates more conformal dose distributions than conventional tandem for all lateral positional shifts of 0-15 mm (CI=0.91–0.52 and 0.99–0.34, respectively), with an exception at the central position due to the ideal circular dose distribution, generated by the {sup 192}Ir, fitting tightly around the circular target (CI = 0.91 and 0.99, respectively). The DMBT tandem is able to generate dose conformity of CI>0.8 at up to 6-mm positional shift while the conventional tandem violates this past 2-mm shift. Also, the CI ratio (=DMBT/conv.) increases rapidly until about 8 mm and then stabilizes beyond. Conclusion: A substantial enhancement in the dose sculpting capacity has been demonstrated for the novel DMBT tandem applicator. While further studies are warranted, the concept is promising for potential clinical translation.

60 APPLIED LIFE SCIENCES↗

MO-AB-BRA-02: Modeling Nanoparticle-Eluting Spacer Degradation During Brachytherapy Application with in Situ Dose-Painting

Purpose: Brachytherapy application with in situ dose-painting using gold nanoparticles (GNP) released from GNP-loaded brachytherapy spacers has been proposed as an innovative approach to increase therapeutic efficacy during brachytherapy. This work investigates the dosimetric impact of slow versus burst release of GNP from next generation biodegradable spacers. Methods: Mathematical models were developed based on experimental data to study the release of GNP from a spacer designed with FDA approved poly(lactic-co-glycolic acid) (PLGA) polymer. The diffusion controlled released process and PLGA polymer degradation kinetics was incorporated in the calculations for the first time. An in vivo determined diffusion coefficient was used for determining the concentration profiles and corresponding dose enhancement based on initial GNP-loading concentrations of 7 mg/g. Results: The results showed that there is significant delay before the concentration profile of GNP diffusion in the tumor is similar to that when burst release is assumed as in previous studies. For example, in the case of burst release after spacer administration, it took up to 25 days for all the GNP to be released from the spacer using diffusion controlled release process only. However, it took up to 45 days when a combined model for both diffusion and polymer degradation processes was used. Based on the tumor concentration profiles, a significant dose enhancement factor (DEF >20%), could be attained at a tumor distances of 5 mm from a spacer loaded with 10 nm GNP sizes. Conclusion: The results highlight the need to take the slow release of GNP from spacers and factors such as biodegradation of polymers into account in research development of GNP-eluting spacers for brachytherapy applications with in-situ dose-painting using gold nanoparticles. The findings suggest that I-125 may be the more appropriate for such applications given the relatively longer half-live compared to other radioisotopes like Pd-103 and Cs-131.

60 APPLIED LIFE SCIENCES↗

WE-DE-201-03: Combined Use of 192Ir, 60Co, and 169Yb Sources with the Novel Direction Modulated Brachytherapy Tandem Applicator for High Dose Rate Brachytherapy Planning of Cervical Cancer

Purpose: To evaluate the improvement in plan quality when various combinations of 192Ir, 60Co, and 169Yb sources are used in combination with a novel direction modulated brachytherapy (DMBT) tandem applicator for high dose rate brachytherapy of cervical cancer. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy (IGABT), especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles - leading to enhanced dose sculpting capacity through inverse planning. Monte Carlo simulations of the three HDR sources individually inside the DMBT applicator were performed and imported into an in-house developed inverse optimization code. We then performed inverse planning with 14 cervical cancer patients enrolled in EMBRACE study. In all patients, 3D MRI-based planning was performed while utilizing 1) tandem-ring and needles attached-to-ring (7 patients) and 2) tandem-ring and needles both attached-to-ring and free-hand-loaded (7 patients), in accordance with the GEC-ESTRO recommendations. All plans were normalized to receive the same HRCTV D90 and DVH parameters were evaluated. Results: The DMBT tandem was used in all cases. Overall, the combined use of two sources (192Ir-60Co and 192Ir-169Yb, but not 60Co-169Yb) generally produced better quality plans than with the 192Ir source alone in terms of sparing OARs. For example, up to 3.5, 4.4, and 3.9% individual reductions in D2cc were observed for the bladder, rectum, and sigmoid, respectively, between 192Ir-60Co and 192Ir-only plans for patient cases in #1. While up to 5.5, 2.0, and 5.7% individual reductions were observed for patient cases in #2. Conclusion: We have demonstrated that, in addition to “directional modulation” of DMBT, use of multiple sources with sufficient differences in energy can be utilized to achieve additional improvement in plan quality for IGABT of cervical cancer.

60 APPLIED LIFE SCIENCES↗

TH-B-204-02: Application of Implanted Markers in Proton Therapy

Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRI compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.

60 APPLIED LIFE SCIENCES↗

TH-F-202-02: Current Applications of MRI in Radiotherapy

MRI has excellent soft tissue contrast and can provide both anatomical and physiological information. It is becoming increasingly important in radiation therapy for treatment planning, image-guided radiation therapy, and treatment assessment. It is critically important at this time point to educate and update our medical physicists about MRI to prepare for the upcoming surge of MRI applications in radiation therapy. This session will review important basics of MR physics, pulse sequence designs, and current radiotherapy application, as well as showcase exciting new developments in MRI that can be potentially useful in radiation therapy. Learning Objectives: To learn basics of MR physics and understand the differences between various pulse sequences To review current applications of MRI in radiation therapy.To discuss recent MRI advances for future MRI guided radiation therapy Partly supported by NIH (1R21CA165384).; W. Miller, Research supported in part by Siemens Healthcare; G. Li, My clinical research is in part supported by NIH U54CA137788. I have a collaborative research project with Philips Healthcare.; J. Cai, jing cai.

60 APPLIED LIFE SCIENCES↗

Application of entropy and signal energy for ultrasound-based classification of three-dimensional printed polyetherketoneketone components

This paper describes a preliminary method for the classification of annealed and unannealed polyetherketoneketone (PEKK) components manufactured using a material extrusion three-dimensional (3D) printing process. PEKK is representative of a class of high-performance thermoplastics that are increasingly employed as feedstocks for use in 3D printing. PEKK components may be used continuously at elevated temperatures, are chemically resistant, and able to withstand large mechanical loads. These properties render PEKK suitable as a metal component replacement in aerospace applications, high-temperature industrial applications, and surgical implants. The structure of PEKK is semi-crystalline with the specific crystallinity correlating to the final properties during application, making determination of this property crucial. This study compares three different signal processing techniques intended to distinguish annealed (high crystallinity) from unannealed (low crystallinity) components using backscattered ultrasound. The first is energy-based and is unable to detect annealing. The second two are based on different entropies of the backscattered signal: a limiting form of Renyi's entropy and a limiting form of joint entropy. The joint entropy values for the annealed and unannealed specimens fall into two non-overlapping intervals and have a statistical separation of two standard deviations.

36 MATERIALS SCIENCE↗

Spin polarized {sup 3}He: From basic research to medical applications

Polarization of {sup 3}He gas by means of optical pumping is well known since the early 1960s with first applications in fundamental physics. Some thirty years later it was discovered, that one can use hyperpolarized {sup 3}He as contrast agent for magnetic resonance imaging of the lung. The wide interest in this new method made it necessary to find ways of polarizing {sup 3}He in large quantities with high polarization degrees. A high performance polarizing facility has been developed at the University of Mainz, designed for centralized production of hyperpolarized {sup 3}He gas. We present the Mainz concept as well as some examples of numerous applications of spin polarized {sup 3}He in fundamental research and medical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modern compact accelerators of cyclotron type for medical applications

Ion beam therapy and hadron therapy are types of external beam radiotherapy. Recently, the vast majority of patients have been treated with protons and carbon ions. Typically, the types of accelerators used for therapy were cyclotrons and synchrocyclotrons. It is intuitively clear that a compact facility fits best to a hospital environment intended for particle therapy and medical diagnostics. Another criterion for selection of accelerators to be mentioned in this article is application of superconducting technology to the magnetic system design of the facility. Compact isochronous cyclotrons, which accelerate protons in the energy range 9–30 MeV, have been widely used for production of radionuclides. Energy of 230 MeV has become canonical for all proton therapy accelerators. Similar application of a carbon beam requires ion energy of 430 MeV/u. Due to application of superconducting coils the magnetic field in these machines can reach 4–5 T and even 9 T in some cases. Medical cyclotrons with an ironless or nearly ironless magnetic system that have a number of advantages over the classical accelerators are in the development stage. In this work an attempt is made to describe some conceptual and technical features of modern accelerators under consideration. The emphasis is placed on the magnetic and acceleration systems along with the beam extraction unit, which are very important from the point of view of the facility compactness and compliance with the strict medical requirements.

43 PARTICLE ACCELERATORS↗

Multilevel Spectral Coarsening for Graph Laplacian Problems with Application to Reservoir Simulation

We extend previously developed two-level coarsening procedures for graph Laplacian problems written in a mixed saddle point form to the fully recursive multilevel case. The resulting hierarchy of discretizations gives rise to a hierarchy of upscaled models, in the sense that they provide approximation in the natural norms (in the mixed setting). This property enables us to utilize them in three applications: (i) as an accurate reduced model, (ii) as a tool in multilevel Monte Carlo simulations (in application to finite volume discretizations), and (iii) for providing a sequence of nonlinear operators in a full approximation scheme for solving nonlinear pressure equations discretized by the conservative two-point flux approximation. Finally, we illustrate the potential of the proposed multilevel technique in all three applications on a number of popular benchmark problems used in reservoir simulation.

multilevel Monte Carlo↗

A Framework for Error-Bounded Approximate Computing, with an Application to Dot Products

Approximate computing techniques, which trade off the computation accuracy of an algorithm for better performance and energy efficiency, have been successful in reducing computation and power costs in several domains. However, error sensitive applications in high-performance computing are unable to benefit from existing approximate computing strategies that are not developed with guaranteed error bounds. While approximate computing techniques can be developed for individual high-performance computing applications by domain specialists, this often requires additional theoretical analysis and potentially extensive software modification. Hence, the development of low-level error-bounded approximate computing strategies that can be introduced into any high-performance computing application without requiring additional analysis or significant software alterations is desirable. In this paper, we provide a contribution in this direction by proposing a general framework for designing error-bounded approximate computing strategies and apply it to the dot product kernel to develop \bf qdot---an error-bounded approximate dot product kernel. Following the introduction of qdot, here we perform a theoretical analysis that yields a deterministic bound on the relative approximation error introduced by qdot. Empirical tests are performed to illustrate the tightness of the derived error bound and to demonstrate the effectiveness of qdot on a synthetic dataset, as well as two scientific benchmarks---the conjugate gradient (CG) and power methods. In some instances, using qdot for the dot products in CG can result in many components being quantized to half precision without increasing the iteration count required for convergence to the same solution as CG using a double precision dot product.

97 MATHEMATICS AND COMPUTING↗

Detectors for Accelerator-Based Security Applications

We present of review of detector systems used in accelerator-based national security applications. In gen-eral, the detectors used for these applications are also used in passive measurements. The critical difference is that detector systems for accelerator-based applications in general need to discriminate beam-generated background from the intended signal. Typical techniques to remove background include shielding, timing, selection of sensitive materials, and choice of accelerator.

Warren, Glen A.↗

Applications of Nuclear and Particle Physics Technology: Particles & Detection — A Brief Overview

Here, a brief overview of the technology applications with significant societal benefit that have their origins in nuclear and particle physics research is presented. It is shown through representative examples that applications of nuclear physics can be classified into two basic areas: 1) applying the results of experimental nuclear physics and 2) applying the tools of experimental nuclear physics. Examples of the application of the tools of experimental nuclear and particle physics research are provided in the fields of accelerator and detector based technologies namely synchrotron light sources, nuclear medicine, ion implantation and radiation therapy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of virtualization on a scientific application - Running a hyperspectral radiative transfer code on virtual machines.

The topic of system-level virtualization has recently begun to receive interest for high performance computing (HPC). This is in part due to the isolation and encapsulation offered by the virtual machine. These traits enable applications to customize their environments and maintain consistent software configurations in their virtual domains. Additionally, there are mechanisms that can be used for fault tolerance like live virtual machine migration. Given these attractive benefits to virtualization, a fundamental question arises, how does this effect my scientific application? We use this as the premise for our paper and observe a real-world scientific code running on a Xen virtual machine. We studied the effects of running a radiative transfer simulation, Hydrolight, on a virtual machine. We discuss our methodology and report observations regarding the usage of virtualization with this application.

Tikotekar, Anand A↗

Irregular Applications: Architectures & Algorithms

Irregular applications are characterized by irregular data structures, control and communication patterns. Novel irregular high performance applications which deal with large data sets and require have recently appeared. Unfortunately, current high performance systems and software infrastructures executes irregular algorithms poorly. Only coordinated efforts by end user, area specialists and computer scientists that consider both the architecture and the software stack may be able to provide solutions to the challenges of modern irregular applications.

99 GENERAL AND MISCELLANEOUS↗