Search NASA⌕ Search

SEARCH · Search NASA

Results for “building development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Measuring Residential Ventilation System Airflows: Part 1 – Laboratory Evaluation of Airflow Meter Devices

Building codes increasingly require tighter homes and mechanical ventilation per ASHRAE Standard 62.2. These ventilation flows must be measured so that energy is not wasted with over ventilation and occupants’ health is not compromised by under ventilation. Flow hoods are used to measure these ventilation flows, but there is currently no standard specifying the measurement procedure and measurement devices that should be used. This study evaluates the accuracy of six commercially available flow hoods under laboratory conditions configured to emulate a residential mechanical ventilation duct system. The measurements taken with the flow hoods were compared to simultaneous measurements taken by an in-line reference flow meter having a known uncertainty. Results indicate that powered flow hoods yield more accurate measurements than non-powered flow hoods, and that a majority of the flow hoods measured inlet flows more accurately than outlet flows. In several cases, there was little resemblance between the manufacturers’ stated accuracy and the accuracy we found in our laboratory measurements. It is clear that current flow hood calibration procedures may not consider field application variables such as flow asymmetry, flow angle, and flow direction. A new flow hood measurement standard that takes these ‘real world’ conditions into account should be developed to ensure that residential buildings receive the intended ventilation flows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring Residential Ventilation System Airflows: Part 1 – Laboratory Evaluation of Airflow Meter Devices

Building codes increasingly require tighter homes and mechanical ventilation per ASHRAE Standard 62.2. These ventilation flows must be measured so that energy is not wasted with over ventilation and occupants’ health is not compromised by under ventilation. Flow hoods are used to measure these ventilation flows, but there is currently no standard specifying the measurement procedure and measurement devices that should be used. This study evaluates the accuracy of six commercially available flow hoods under laboratory conditions configured to emulate a residential mechanical ventilation duct system. The measurements taken with the flow hoods were compared to simultaneous measurements taken by an in-line reference flow meter having a known uncertainty. Results indicate that powered flow hoods yield more accurate measurements than non-powered flow hoods, and that a majority of the flow hoods measured inlet flows more accurately than outlet flows. In several cases, there was little resemblance between the manufacturers’ stated accuracy and the accuracy we found in our laboratory measurements. It is clear that current flow hood calibration procedures may not consider field application variables such as flow asymmetry, flow angle, and flow direction. A new flow hood measurement standard that takes these ‘real world’ conditions into account should be developed to ensure that residential buildings receive the intended ventilation flows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The TRIPOD e-learning Platform for the Training of Earthquake Safety Assessment

The paper summarizes the results of the in progress EU Project titled TRIPOD (Training Civil Engineers on Post-Earthquake Safety Assessment of Damaged Buildings), funded under the Leonardo Da Vinci program. The main theme of the project is the development of a methodology and a learning platform for the training of technicians involved in post-earthquake building safety inspections. In the event of a catastrophic earthquake, emergency building inspections constitute a major undertaking with severe social impact. Given the inevitable chaotic conditions and the urgent need of a great number of specialized individuals to carry out inspections, past experience indicates that inspection teams are often formed in an adhoc manner, under stressful conditions, at a varying levels of technical expertise and experience, sometime impairing the reliability and consistency of the inspection results. Furthermore each Country has its own building damage and safety assessment methodology, developed according to its experience, laws, building technology and seismicity. This holds also for the partners participating to the project (Greece, Italy, Turkey, Cyprus), that all come from seismically sensitive Mediterranean countries. The project aims at alleviating the above shortcomings by designing and developing a training methodology and e-platform, forming a complete training program targeted at inspection engineers, specialized personnel and civil protection agencies. The e-learning platform will provide flexible and friendly authoring mechanisms, self-teaching and assessment capabilities, course and trainee management, etc. Courses will be also made available as stand-alone multimedia applications on CD and in the form of a complete pocket handbook. Moreover the project will offer the possibility of upgrading different experiences and practices: a first step towards the harmonization of methodologies and tools of different Countries sharing similar problems. Finally, through wide dissemination activities, the final aim of the project is to ensure the deployment and the integration into existing earthquake mitigation policies and vocational training schemes.

58 GEOSCIENCES↗

Building Specifications

The building in the top photo is the new home of the National Permanent Savings Bank in Washington, D.C., designed by Hartman-Cox Architects. Its construction was based on a money-saving method of preparing building specifications which derived from NASA technology developed to obtain quality construction while holding down cost of launch facilities, test centers and other structures. Written technical specifications spell out materials and components to be used on construction projects and identify the quality tests each item must pass. Specifications can have major impact on construction costs. Poorly formulated specifications can lead to unacceptable construction which must be replaced, unnecessarily high materials costs, safety hazards, disputes and often additional costs due to delays and litigation. NASA's Langley Research Center developed a novel approach to providing accurate, uniform, cost-effective specifications which can be readily updated to incorporate new building technologies. Called SPECSINTACT, it is a computerized - system accessible to all NASA centers involved in construction programs. The system contains a comprehensive catalog of master specifications applicable to many types of construction. It enables designers of any structure to call out relevant sections from computer storage and modify them to fit the needs of the project at hand. Architects and engineers can save time by concentrating their efforts on needed modifications rather than developing all specifications from scratch. Successful use of SPECSINTACT has led to a number of spinoff systems. One of the first was MASTERSPEC, developed from NASA's experience by Production Systems for Architects and Engineers, Inc., an organization established by the American Institute of Architects. MASTERSPEC, used in construction of the bank building pictured, follows the same basic format as SPECSINTACT and can be used in either automated or manual modes. The striking appearance of the bank building shows that, while MASTERSPEC saves time and money, its use involves no sacrfice in architectural design freedom. The Naval Engineering Facilities Command employs an automated specifications system based on SPECSINTACT. The Public Buildings Service of the General Services Administration used SPECSINTACT as a starting point in a plan to make its guideline specifications available to architects and engineers on a nationwide computer network. Public Technology, Inc., a NASA Technology Application Team, is working with Production Systems for Architects and Engineers, Inc., to promote widespread use of the system by state and local governments for cost benefits to taxpayers.

Source record↗

Independent Technical Assessment of NASA and External Quantum Sensing Capability

The recent FY 2020 federal Research and Development Budget Priorities memo addresses the leadership need in Quantum Information Science (QIS) directing agencies to “prioritize QIS research and development (R&D), which will build the technical and scientific base necessary to explore the next generation of QIS theory, devices, and applications.” Quantum Sensing (QS) is an integral part of QIS. NASA is a key part of the directive to forward American space exploration and commercialization by providing “capabilities that have broad potential applications in space and on Earth.” QS provides an arena for NASA to demonstrate leadership in both areas of the administrative directive. QS uses quantum properties to achieve unprecedented measurement sensitivity and performance, including quantum-enhanced methodologies that outperform their classical counterparts. Typical quantum sensors exploit techniques such as atomic systems, matter waves, quantum entanglement, quantum superposition of states, quantum illumination methods, and manipulation of photons and atoms, in general. Guided by advancements in our ability to generate, manipulate, and control quantum systems, the emerging quantum sensing technologies promise unrivalled sensitivity, resolution, and precision, potentially leading to game-changing applications. Significant gains include technologies important for a range of NASA missions such as remote sensing, in situ measurements, metrology, interferometry, quantum communication, ranging, imaging, radar and lidar receivers, and gravity measurements. NASA Engineering and Safety Center has convened an independent external panel, comprising of Quantum Sensing Experts from Government, DoD, academia, and Federally funded Research and Development Center to conduct an independent technical assessment of the agency's capabilities in Quantum Sensing to understand NASA's internal needs and competencies related to Quantum Sensing and compare agency capabilities with those available externally including industry, academia, and other government agencies. The outcomes of the assessment will help the agency in establishing appropriate strategies and investments to develop and maintain the state-of-the-art sensing competence and capabilities required to meet the agency’s future needs. The External Experts Panel (EEP) is collaborating with HQ, various NASA Center and the representatives in the NASA Quantum Sensing Community of Practice (QS CoP), a part of NASA Sensors and Instrumentation Technical Fellow Technical Discipline Team, in obtaining common, current understanding of agency mission needs where QS can be an important enabler for future needs, and any programs, projects, assets, and technologists working in QS. The EEP organized a Quantum Sensing Workshop of practitioners from industry, academia, other government agencies, external experts, and interested NASA personnel to gather the assessment information. EEP also conducted information gathering on the industry at large, educational institutions, and other government agency research efforts for capture in the assessment database. At the conclusion of this assessment, EEP team will develop findings and conclusions describing NASA’s capabilities for the mission needs, NASA's relative position on new, enabling technologies, and an analysis of the gaps that may present any risks to near-term or far-term mission needs. This presentation will give details of the NASA and External Quantum Sensing Assessment outcomes, findings, observations, and its recommendation to NASA as how it can advance Quantum Sensing technologies and techniques for its science and explorations related missions.

External Quantum Sensing Capability↗

Field measurement of moisture-buffering model inputs for residential buildings

Moisture adsorption and desorption in building materials impact indoor humidity. This effect should be included in building-energy simulations, particularly when humidity is being investigated or controlled. Several models can calculate this moisture-buffering effect, but accurate ones require model inputs that are not always known to the user of the building-energy simulation. This research developed an empirical method to extract whole-house model inputs for the effective moisture penetration depth (EMPD) model. The experimental approach was to subject the materials in the house to a square-wave relative-humidity profile, measure all of the moisture-transfer terms (e.g., infiltration, air-conditioner condensate), and calculate the only unmeasured term—the moisture sorption into the materials. We validated this method with laboratory measurements, which we used to measure the EMPD model inputs of two houses. After deriving these inputs, we measured the humidity of the same houses during tests with realistic latent and sensible loads and demonstrated the accuracy of this approach. Furthermore, these results show that the EMPD model, when given reasonable inputs, is an accurate moisture-buffering model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology for Evaluating Cost-Effectiveness of Residential Energy Code Changes

DOE's Building Energy Codes Program has developed and established a methodology for evaluating the energy and economic performance of residential energy codes. This methodology serves two primary purposes. First, as DOE participates in the consensus processes of the International Code Council, the methodology described herein will be used by DOE to ensure that its proposals are both energy efficient and cost-effective. Second, when a new version of the International Energy Conservation Code is published, DOE will evaluate the new code as a whole to establish expected energy savings and cost-effectiveness, which will help states and local jurisdictions interested in adopting the new codes. DOE's measure of cost-effectiveness balances longer-term energy savings against additions to initial costs through a life-cycle cost perspective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Partnership for Edge Physics Simulation (EPSI)

We propose to develop advanced simulation codes, based upon an extreme parallelism, first principles kinetic approach, to address the challenges associated with the edge region of magnetically confined plasmas. This work is relevant to both existing magnetic fusion facilities and essential for next-generation burning plasma experiments, such as ITER where success is critically dependent upon H-mode operation achieving an edge pedestal of sufficient height for good core plasma performance without producing deleterious large scale edge localized instabilities. The plasma edge presents a well-known set of multi-physics, multi-scale problems involving complex 3D magnetic geometry. Perhaps the greatest computational challenge is the lack of scale separation – temporal scales for drift waves, Alfven waves, ELM dynamics for example have strong overlap. Similar overlap occurs on the spatial scales for the ion poloidal gyro-radius, drift wave and pedestal width. The traditional approach of separating fusion problems into weakly interacting spatial or temporal domains clearly breaks down in the edge. A full kinetic model (full-f model) must be solved to understand and predict the edge physics including non-equilibrium thermodynamic issues arising from the magnetic topology (the open field lines producing a spatially sensitive velocity hole), plasma wall interactions, neutral and atomic physics. The plan here is to model these phenomena within a comprehensive first principles set of equations without the need for the insurmountable multiple-codes coupling issues by building on the XGC1 code developed under the SciDAC Proto-FSP Center for Plasma Edge Simulation (CPES). This proposal includes the critical participants in the XGC1 development. We propose enhancing the capability of XGC1 by including all the important turbulence physics contained in kinetic ion and electron electromagnetic dynamics, by extending the PIC technology to incorporate several positive features found in the Eulerian grid technology, combining the coarse grained XGC0 code into it with a multiscale projective time integration technique to be developed in the project for experimental time scale simulation of the edge multi-physics, and by implementing modern computational technologies to move forward with the extreme scale heterogeneous hardware/software platform development. Ultra-fast edge localized instabilities, involving compressional Alven modes, will be studied using a proper MHD or two-fluid codes employing kinetic closure information from XGC. The proposed research integrates the most important physical processes on overlapping temporal and spatial scales, to study (i) transitions and thresholds for enhanced confinement regimes, (ii) the predictive understanding of the edge pedestal formation, structure and dynamics, (iii) the effect of the edge plasma on the core confinement, (iv) the physics of Edge Localized Modes and their suppression or mitigation via external control techniques, and (v) the heat load on the material wall. Our approach will implement physical models that are valid in their relevant collisionality regimes for current experiments and future burning plasma devices. Comparisons with experimental data will be made at multiple levels including characterization of turbulence dynamics, flux-gradient responses in the energy, particle and momentum channels, and observations of global phenomena such as L-H transitions, momentum generation, ELM dynamics, ELM-free regimes and the tokamak density limit. The proposal team has established strong connections, through joint membership, with other organizations that will be critical for success. These include FASTMath, SUPER and QUEST Institutes respectively for meshing tools and solvers; code performance tuning and uncertainty quantification as well as a proposed Data Management and Visualization Institute.. We will also be teaming with ongoing fusion SciDAC’s: CSWPI for RF-edge plasmas interactions; CEMM for the M3D MHD simulations and with PEPSC for incorporation of energetic particle physics. Finally, the team includes representatives from each of the major U.S. experimental facilities who will coordinate the validation program and the development of synthetic diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Scale Integrated Monitoring System for Enhancing Methane Emission Detection, Quantification & Prediction

This report details the progress and findings of a comprehensive study on reviewing existing solutions, identifying technology gaps, and formulating an “all-in-one” integrated strategy for developing the next-generation multiscale methane monitoring and modeling platform, conducted under grant number DE-FE0032292. Co-led by Dr. David Ebert, Dr. Binbin Weng, and Dr. Chenghao Wang at the University of Oklahoma, the project’s goal was to develop an integrated approach for building this engineering platform to detect, quantify, and mitigate methane emissions across various temporal scale, spatial scales, and sectors. The planning grant study began with an extensive review of various methane sensing and monitoring technologies and systems, surveying over 100 technology providers globally. This review revealed the prevalence of optical methods over chemical methods in commercially available sensors, with Non-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), and Optical Gas Imaging (OGI) cameras being the most prevalent options. A trend towards more advanced optical techniques was observed, driven by increased regulatory focus and technological advancements. The technical evaluation of these sensing technologies provided crucial insights into their capabilities and limitations. The study examined emerging technologies such as Differential Absorption LiDAR (DIAL), which show promise for high-precision and long-range detection. The team then investigated the features and application bandwidth of various sensing platforms, including handheld, fixed/stationary, mobile, aerials, and spaceborne monitors. Pilot field studies were conducted to assess the capabilities of solutions for different emission scenarios. Field work with sensor deployments was conducted at three distinct site types: an oil & gas industry site, a cattle ranching operation, and a waste processing facility. The team also conducted a thorough review of methane flux inverse modeling approaches, focused on physically based methods. These approaches were categorized into simple, intermediate, and advanced methods. A realtime WRF-GHG (Weather Research and Forecasting-Greenhouse Gas) modeling system was developed and applied, incorporating multiple data sources to guide field experiments and inform methane plume detection. The project identified and analyzed numerous categories of methane data sources, including satellite measurements, ground-based sensors, and inventory databases. Key platforms examined include EDGAR, EPA GHGI, NASA TROPOMI, Carbon Mapper, and Climate TRACE, among others. The team proposed an architecture for a comprehensive methane monitoring platform. This system incorporates multi-source data acquisition, advanced data processing and assimilation, interactive visualization tools, and analytical capabilities for emissions forecasting and scenario analysis. The proposed platform aims to provide a user-friendly interface catering to various stakeholders, from researchers to policymakers. The architecture includes sophisticated data ingestion methods, a centralized data warehouse, and advanced analytical tools for data fusion and interpretation. To ensure the relevance and effectiveness of the proposed system, a comprehensive survey was conducted to gather stakeholder input on system requirements. Key findings include a strong need for integrating various data types and formats, a preference for real-time data updates and advanced visualization tools, and a demand for user-friendly interfaces catering to different expertise levels.

03 NATURAL GAS↗

Energy Evaluation of a New Construction Pilot Community: Fresno, California

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the Building America House Simulation Protocols developed by NREL. Builders face several key problems when implementing a whole-house systems integrated measures package from a single test house into multiple houses. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a measures package and the actual utility usage in the houses at the community scale of production. Five occupants participated in this research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards a framework for selection of supervisory control for commercial buildings: HVAC system energy efficiency

This paper develops and utilizes an optimization based framework to investigate the maximal energy efficiency potentially attainable by HVAC system operation in a non-predictive context. Performance is evaluated relative to the existing state of the art set-point reset strategies. The expected efficiency increase driven by operation constraints relaxations is evaluated.

Ramachandran, Thiagarajan↗

Development and Testing of QpWeak Luminosity Monitors

Building on advances in recent parity experiments at Jefferson Lab, the opportunity exists to make the first precision measurement of the weak charge of the proton, Qp Weak. The Qp Weak experiment will measure the asymmetry in the scattering of longitudinally polarized electrons on a liquid hydrogen target. The luminosity monitors, placed at forward scattering angles, will be used for monitoring sources of false asymmetry and target density fluctuations. The luminosity monitors will consist of an array of Cerenkov quartz coupled to photomultiplier tubes by air light guides. It is therefore essential to quantify the linearity of the response of the luminosity monitor PMTs. This is being tested with a small asymmetry and a complete electronics chain designed to mimic experimental conditions. Additionally, the air light guides are being constructed and tested for transmission efficiency using cosmic ray events incident on the quartz Cerenkov radiators.

Finelli, Kevin↗

Hybrid Tandem Photovoltaics

Tandem solar cell structures are the only strategy demonstrated to surpass the detailed balance efficiency limit of high-quality single-junction solar cells. To continue to improve the efficiencies of cost-effective terrestrial solar power, hybrid tandems of dissimilar subcells are being considered by many around the world, especially designs that incorporate silicon solar cells as a bottom subcell. In this project, we studied a wide variety of tandem design possibilities including those with three-terminal (3T) and four-terminal (4T) configurations. The use of 3T and 4T designs could be useful for efficient and economical hybrid tandem designs that utilize the best available subcell materials such as emerging perovskite materials. Three-terminal configurations, in particular, have not been sufficiently studied previously. We have laid the foundational groundwork in this project for understanding the operation of 3T tandems: developing a taxonomy for naming, a methodology for measuring and interconnecting, and models for simply characterizing 3T tandems. Electrical and optical subcell coupling between the subcells was also measured and modeled. An important part of this work was the fabrication of novel example tandem structures, including 4T GaAs/Si, 3T GaInP/Si, 3T GaAs/Si, and 3T GaInP/GaAs devices. Using these high-quality tandem cells, we have been able to clearly demonstrate the achievability of high-efficiencies, and subtle physical effects such as photon recycling and luminescent coupling. We have developed and demonstrated essential building-block tools such as transparent conductive adhesives (TCA) and 3T silicon bottom cells with interdigitated back contacts (IBC) that can also be used in many other tandem designs. We have tested the reliability of these tools and devices under standardized testing and outdoor measurements. We have found 4T GaAs/Si tandems to be relatively straightforward to fabricate and robust in real-world outdoor conditions. While we have demonstrated working hybrid 3T III-V/TCA/Si IBC tandems, we experienced low yields even with our best process flows yet. Further work is still needed to improve the processing yield of these devices. We therefore also created tandem cells using an all-III-V 3T tandem process which was very robust with high yields, allowing for the creation of voltage-matched strings in many different configurations using 8 nearly identical 3T tandems. Using these robust 3T tandem examples, we were able measure and precisely characterize 3T tandem behaviors to predict their operation under changing spectrum and temperature. The optoelectronic equivalent-circuit model was shown to be very general and applicable to hybrid tandems, and encompassed the operation 3T Si IBC cells. This general model has been distributed to the public in as open-source Python-based software called PVcircuit. We have calculated the implications of these new tandem device designs on the real-world energy production and shown how the relative performance of different tandem configurations is situational and can be engineered using the tools developed here.

14 SOLAR ENERGY↗

Collaborative Systemwide Monitoring and Evaluation Project (CSMEP) - Year 5 : Annual Report for FY 2008.

The Collaborative Systemwide Monitoring and Evaluation Project (CSMEP) is a coordinated effort to improve the quality, consistency, and focus of fish population and habitat data to answer key monitoring and evaluation questions relevant to major decisions in the Columbia River Basin. CSMEP was initiated by the Columbia Basin Fish and Wildlife Authority (CBFWA) in October 2003. The project is funded by the Bonneville Power Administration (BPA) through the Northwest Power and Conservation Council's Fish and Wildlife Program (NPCC). CSMEP is a major effort of the federal state and Tribal fish and wildlife managers to develop regionally integrated monitoring and evaluation (M&E) across the Columbia River Basin. CSMEP has focused its work on five monitoring domains: status and trends monitoring of populations and action effectiveness monitoring of habitat, harvest, hatcheries, and the hydrosystem. CSMEP's specific goals are to: (1) interact with federal, state and tribal programmatic and technical entities responsible for M&E of fish and wildlife, to ensure that work plans developed and executed under this project are well integrated with ongoing work by these entities; (2) document, integrate, and make available existing monitoring data on listed salmon, steelhead, bull trout and other fish species of concern; (3) critically assess strengths and weaknesses of these data for answering key monitoring questions; and (4) collaboratively design, implement and evaluate improved M&E methods with other programmatic entities in the Pacific Northwest. During FY2008 CSMEP biologists continued their reviews of the strengths and weaknesses (S&W) of existing subbasin inventory data for addressing monitoring questions about population status and trends at different spatial and temporal scales. Work was focused on Lower Columbia Chinook and steelhead, Snake River fall Chinook, Upper Columbia Spring Chinook and steelhead, and Middle Columbia River Chinook and steelhead. These FY2008 data assessments and others assembled over the years of the CSMEP project can be accessed on the CBFWA public website. The CSMEP web database (http://csmep.streamnet.org/) houses metadata inventories from S&W assessments of Columbia River Basin watersheds that were completed prior to FY2008. These older S&W assessments are maintained by StreamNet, but budget cutbacks prevented us from adding the new FY2008 assessments into the database. Progress was made in FY2008 on CSMEP's goals of collaborative design of improved M&E methods. CSMEP convened two monitoring design workshops in Portland (December 5 and 6, 2007 and February 11 and 12, 2008) to continue exploration of how best to integrate the most robust features of existing M&E programs with new approaches. CSMEP continued to build on this information to develop improved designs and analytical tools for monitoring the status and trends of fish populations and the effectiveness of hatchery and hydrosystem recovery actions within the Columbia River Basin. CSMEP did not do any new work on habitat or harvest effectiveness monitoring designs in FY2008 due to budget cutbacks. CSMEP presented the results of the Snake Basin Pilot Study to the Independent Scientific Review Panel (ISRP) in Portland on December 7, 2008. This study is the finalization of CSMEP's pilot exercise of developing design alternatives across different M&E domains within the Snake River Basin spring/summer Chinook ESU. This work has been summarized in two linked reports (CSMEP 2007a and CSMEP 2007b). CSMEP participants presented many of the analyses developed for the Snake Basin Pilot work at the Western Division American Fisheries Society (AFS) conference in Portland on May 4 to 7, 2008. For the AFS conference CSMEP organized a symposium on regional monitoring and evaluation approaches. A presentation on CSMEP's Cost Integration Database Tool and Salmon Viability Monitoring Simulation Model developed for the Snake Basin Pilot Study was also given to the Pacific Northwest Aquatic monitoring Partnership (PNAMP) steering committee in Portland on August 28, 2008. Further information on CSMEP strengths and weaknesses assessments and monitoring design products for FY2008 is presented in the main text and appendices of this Annual Report as well as being available on CBFWA's public website.

13 HYDRO ENERGY↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thomas Leps Internship Abstract

An optical navigation system is being flown as the backup system to the primary Deep Space Network telemetry for navigation and guidance purposes on Orion. This is required to ensure Orion can recover from a loss of communication, which would simultaneously cause a loss of DSN telemetry. Images taken of the Moon and Earth are used to give range and position information to the navigation computer for trajectory calculations and maneuver execution. To get telemetry data from these images, the size and location of the moon need to be calculated with high accuracy and precision. The reentry envelope for the Orion EM-1 mission requires the centroid and radius of the moon images to be determined within 1/3 of a pixel 3 sigma. In order to ensure this accuracy and precision can be attained, I was tasked with building precise dot grid images for camera calibration as well as building a hardware in the loop test stand for flight software and hardware proofing. To calibrate the Op-Nav camera a dot grid is imaged with the camera, the error between the image dot location and the actual dot location can be used to build a distortion map of the camera and lens system so that images can be fixed to display truth locations. To build the dot grid images I used the Electro Optics Lab optical bench Bright Object Simulator System, and gimbal. The gimbal was slewed to a series of elevations and azimuths. An image of the collimated single point light source was then taken at each position. After a series of 99 images were taken at different locations the single light spots were extracted from each image and added to a composite image containing all 99 points. During the development of these grids it was noticed that an intermittent error in the artificial "star" locations occurred. Prior to the summer this error was attributed to the gimbal having glitches in it's pointing direction and was going to be replaced, however after further examining the issue I determined it to be a software issue. I have since narrowed the likely source of the error down to a Software Development Kit released by the camera supplier PixeLink. I have since developed a workaround in order to build star grids for calibration until the software bug can be isolated and fixed. I was also tasked with building a Hardware in the Loop test stand in order to test the full Op-Nav system. A 4k screen displays simulated Lunar and Terrestrial images from a possible Orion trajectory. These images are then projected through a collimator and then captured with an Op-Nav camera controlled by an Intel NUC computer running flight software. The flight software then analyzes the images to determine attitude and position, this data is then reconstructed into a trajectory and matched to the simulated trajectory in order to determine the accuracy of the attitude and position estimates. In order for the system to work it needs to be precisely and accurately aligned. I developed an alignment procedure that allows the screen, collimator and camera to be squared, centered and collinear with each other within a micron spatially and 5 arcseconds in rotation. I also designed a rigid mount for the screen that was machined on site in Building 10 by another intern. While I was working in the EOL we received a $500k Orion startracker for alignment procedure testing. Due to my prior experience in electronics development, as an ancillary duty, I was tasked with building the cables required to operate and power the startracker. If any errors are made building these cables the startracker would be destroyed, I was honored that the director of the lab entrusted such a critical component with me. This internship has cemented my view on public space exploration. I always preferred public sector to privatization because, as a scientist, the most interesting aspects of space for me are not necessarily the most profitable. I was concerned that the public sector was faltering however, and that in order to improve human space exploration I would be forced into private sector. I now know that, at least at JSC, human spaceflight is still progressing, and exciting work is still being done. I am now actively seeking employment at JSC after I complete my Ph.D and have met with my branch chiefs and mentor to discuss transitioning to a grad Co-op position.

Leps, Thomas↗

Retrofitting Garden-Style Apartments in Brooklyn, New York

This research effort sought to achieve a solution package that yields energy savings greater than 30% over the pre-existing conditions in a minimally intrusive multifamily retrofit project. The Consortium for Advanced Residential Buildings (CARB) partnered with L+M Development Partners, Inc. on a Mitchell-Lama Housing Program project, Marcus Garvey Village, in Brooklyn, NY (Climate Zone 4A). The Mitchell-Lama Housing Program is a form of housing subsidy in the state of New York that provides affordable rental and cooperative housing to moderate- and middle-income families. Marcus Garvey Village was founded in 1975 and contains 625 residential units (ranging from studios to 5-bedroom units) in thirty-two 4-story garden-style apartment structures built with concrete and faced in light brown brick. The single largest challenge for implementation of energy conservation measures at Marcus Garvey was working within occupied spaces. Measures are being implemented in phases to minimize disruption. As of August 2015, the retrofit work is over 50% complete. The wall insulation, sealing of the through wall AC vent, and installation of new oil-filled electric baseboards with advanced controls are conducted at one time, limiting disruption to the living room space. In a similar fashion, the kitchen work is done, then the bathroom. The final selection of energy conservation measures is projected to save 26.5% in source energy with a cost just under $3.7 million and utility bill savings of nearly $480,000 (of an average $1.8 million annual utility cost for the development).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗