Search NASA⌕ Search

SEARCH · Search NASA

Results for “condition based monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Spaceborne Lidar Retrievals of PM2.5 for Air Quality Studies and Applications

Fine particulate matter (PM2.5) substantially contributes to air pollution and negatively affects human health. While many studies have investigated the use of passive column-integrated aerosol optical depth to infer surface PM2.5, the use of lidar observations for air quality characterization is not nearly as extensive. Lidar measurements are critical, however, due to the vertical aerosol information they provide, including near the surface. In this presentation, we first provide an overview of various lidar-based approaches for estimating PM2.5 concentrations and then discuss how lidar measurements can assist other air quality applications. For example, estimates of PM2.5 have been obtained in a physics-based approach through CALIOP near-surface aerosol extinction retrievals, assumptions on the mass extinction efficiency, and incorporating other parameters (an aerosol hygroscopic growth factor and PM2.5/PM10 ratio). Application of this algorithm over the contiguous United States (CONUS) from 2006 to 2018 yielded larger PM2.5 values over the eastern and western CONUS (~10-15 μg/m³) and lower PM2.5 levels in the central CONUS (~5 μg/m³). These spatial patterns were similar to those from gridded PM2.5 concentrations obtained through in situ measurements at ground stations operated by the US Environmental Protection Agency. In another approach, the Cloud Aerosol Transport System (CATS) lidar was used with the Goddard Earth Observing System (GEOS) model in a 1D ensemble-based variational technique to obtain PM2.5 over the US and Europe, and the spatial patterns of the CATS/GEOS based PM2.5 concentrations generally captured those from surface stations (with corresponding hourly EPA PM2.5 vs CATS PM2.5 statistics of R=0.4 and bias=1.5 μg/m³). In our recent work, as part of the Models, In situ, and Remote sensing of Aerosols (MIRA) Working Group, we have applied both the CALIOP and CATS/GEOS based approaches over the highly polluted country of India during the post-monsoon season (September-October 2016). We derived elevated levels of two-month mean PM2.5 (~100 μg/m³) in northern India, especially near New Delhi. These high PM2.5 concentrations in the Indo-Gangetic plain are driven in large part from the seasonal burning of crop residue and meteorological conditions typical at this time of the year, such as low wind speeds and a shallow boundary layer. While the satellite-derived PM2.5 moderately replicates (R = ~0.7-0.9) the spatial variability in the two-month mean of surface in situ PM2.5 from monitoring sites operated by the Central and State Pollution Control Boards, we show results from specific scenes for which there are large deviations between the satellite-derived PM2.5 and in situ measurements. Other current work on this topic focuses on developing PM2.5 estimates using airborne high spectral resolution lidar measurements through machine learning regression algorithms and involves several parameters (e.g., aerosol extinction, color ratio, lidar ratio). Application of this method over major metropolitan areas in the US and Asia have resulted in high correlations (R = 0.93) with surface measurements. This airborne lidar approach can be adapted to spaceborne lidar measurements, and all three of these approaches can be applied to ESA’s EarthCARE Atmospheric Lidar instrument, setting the stage for the future Cloud Aerosol Lidar for Global Scale Observations of the Ocean-Land Atmosphere System (CALIGOLA) mission. Ultimately, beyond estimates of PM2.5, the aerosol vertical distribution from lidars can benefit studies involving passive sensor approaches for PM2.5 proxies (including from geostationary satellites), wildfire smoke plume injection heights, volcanic emissions (e.g., ash height retrievals), and aerosol/air quality model assimilation, evaluation, and forecasts.

Travis D Toth↗

Bayesian Approach to Estimation of Water Table Elevations Using Historical Rasters as Prior Information 2019 - 20430

In cases of complex but only partially known geology and a lack of spatial control in observation well locations, water table elevation estimation is very challenging. In some cases, auxiliary information, such as observations of the movement of tracers, operation of injection and extraction wells, and calibration of groundwater models against the historical elevation data, can be combined with expert judgement to estimate flow directions in areas of sparse data and to aid in the production of more reliable contour maps (and associated rasters) than could be produced by relying on sparse well elevation data alone. Given a historical sequence of these raster maps, the question arises how to automate, to the extent possible, the process of producing new raster maps to reflect data from previous times, the current data and the operation of expert judgement. One solution is to adopt a Bayesian point of view and to regard the historical well elevation data, auxiliary information and historical raster maps as prior information. The well elevations for water table wells, as well as those for injection/extraction wells and the data associated with other relevant variables, can be viewed as predictors for the raster surface. From this prior information, we can, conditional on the values of these predictors for a new time period, compute an expected value map and a standard deviation map for the new raster. These then can be taken to specify a prior predictive distribution for the pixels in the new raster map. Then we condition the pixels, corresponding to water level observation wells within the raster, on the observed values in those wells (which in general will differ from the regression estimate) for the new time period. Given the smoothness of the water table surface, we then smooth the surface of deviations from the mean surface, based on the variograms of the historical rasters, and add this smoothed surface to the regression mean surface. The error structure of the produced raster map is defined by the regression error structure and the error due to smoothing based on the estimated variograms. This methodology has been developed and is being further refined for groundwater monitoring and remediation at LANL. It is a very flexible method that can also be applied with a variety of other predictors applied to model the water level wells in the area of interest over the historical record. The smoothness of the spatial process and its possible evolution over time can then be estimated from the residuals from this regression. This can be augmented by expert hydrogeological opinion based on site topography and hydrogeology. (authors)

54 ENVIRONMENTAL SCIENCES↗

Development of a Digital Twin for Hydrogen Dispersion and Safety Assessment in an Electrolyzer-Based Hydrogen Production Facility: Preprint

Digital twin models are virtual representations of physical systems that use real-time data to simulate and optimize performance. This study presents the development and initial implementation of a digital twin (DT) for the electrolyzer-based hydrogen production facility at the National Renewable Energy Laboratory (NREL)'s Advanced Research on Integrated Energy Systems (ARIES), focused on enhancing safety and optimizing sensor placement through physics-based simulations and metadata integration. The DT incorporates detailed facility-specific information, including component layout, leak locations, and controlled release parameters, to model hydrogen dispersion under varying environmental conditions. Using steady-state computational fluid dynamics (CFD) simulations informed by real meteorological data, such as wind speed, direction, and vertical wind profiles, the DT enables visualization of hydrogen plume behavior and spatial concentration distributions. Comparative analysis between high and low wind speed scenarios illustrates the significant influence of wind dynamics on plume shape and extent, with horizontal momentum dominating dispersion at higher speeds, while buoyancy effects become more prominent under low wind conditions. These simulations generate a rich dataset embedded within the DT, allowing users to assess potential leak outcomes and identify optimal sensor locations based on concentration thresholds. The model supports scenario-based analysis to guide safety strategies and equipment deployment for open-area hydrogen infrastructure. The digital twin thus serves as a dynamic platform for virtual prototyping, providing predictive insight into hydrogen behavior and enhancing risk-informed decision-making. This initial phase establishes a validated foundation for future integration of transient, uncontrolled leak scenarios and real-time sensor feedback, positioning the DT as a critical tool for safety design, operational planning, and adaptive monitoring in hydrogen systems. Overall, the approach demonstrates the value of combining environmental data with digital simulations to inform safer and more efficient deployment of hydrogen technologies.

08 HYDROGEN↗

Thermal Conductivity and Water Vapor Stability of Ceramic HfO2-Based Coating Materials

HfO2-Y2O3 and La2Zr2O7 are candidate thermal/environmental barrier coating materials for gas turbine ceramic matrix composite (CMC) combustor liner applications because of their relatively low thermal conductivity and high temperature capability. In this paper, thermal conductivity and high temperature phase stability of plasma-sprayed coatings and/or hot-pressed HfO2-5mol%Y2O3, HfO2-15mol%Y2O3 and La2Zr2O7 were evaluated at temperatures up to 1700 C using a steady-state laser heat-flux technique. Sintering behavior of the plasma-sprayed coatings was determined by monitoring the thermal conductivity increases during a 20-hour test period at various temperatures. Durability and failure mechanisms of the HfO2-Y2O3 and La2Zr2O7 coatings on mullite/SiC Hexoloy or CMC substrates were investigated at 1650 C under thermal gradient cyclic conditions. Coating design and testing issues for the 1650 C thermal/environmental barrier coating applications will also be discussed.

Zhu, Dong-Ming↗

Unlocking the potential of DNA-based tagging: current market solutions and expanding horizons

The commercialization of DNA tagging is a growing trend that demonstrates the increasing practicality of this novel approach. This interdisciplinary technology is based on the distinctive characteristics of DNA as a molecule that can remain stable in varying environmental conditions and store data following appropriate preparation. Moreover, newly developed technologies could simplify DNA synthesis and the encoding of data within DNA. The implementation of DNA tagging presents distinctive benefits in comparison to conventional labelling techniques, including universal product code (UPC) barcoding, radio-frequency identification (RFID), quick response (QR) codes, and Bluetooth technologies, by surmounting the limitations encountered by these systems. The discourse pertains to extant DNA-tagging mechanisms along with prospective implementations in a wide range of domains, including but not limited to art, the metaverse, forensics, wildlife monitoring, and the military. The potential of DNA labelling in various contexts underscores the importance of continued research and development in this rapidly evolving field.

59 BASIC BIOLOGICAL SCIENCES↗

Independent Technical Review of the Interim Measure Alternatives Analysis for Chromium Contamination in Groundwater at Los Alamos National Laboratory, New Mexico

The two example scenarios described in the report are built around either boundary condition modification or pump and treat. Boundary condition modification focuses primarily on aggressively reducing the driving force of water that is moving Cr(VI) through the subsurface system at LANL, carefully monitoring hydrologic responses, and quantifying natural attenuation rates in key portions of the plume. This scenario would provide a measurable impact on subsurface hydrology using relatively low-cost methods and emphasizing data collection to support the CME process. The second scenario focuses on active removal of Cr(VI) using pump and treat combined with a variety of data collection activities. This scenario would also include some boundary condition modification and would provide more timely impacts in the mid-plume area. However, it is substantially more costly and faces more significant logistical, regulatory, and data interpretation hurdles. Because of these issues and challenges, the pump and treat based scenario would be appropriate primarily for the case in which Cr(VI) removal and more rapid near-term impacts in the mid-plume are considered to be high, overriding priorities. We recommend careful consideration of the advantages and disadvantages of different “combined remedy” IM scenarios and urge the LANL team and its regulators and stakeholders to assemble and select a scenario that is implementable and that provides useful and actionable data to inform and support the CME. Both of the example scenarios presented meet these criteria.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A methodology for dam inventory and inspection with remotely sensed data

A methodology is presented to increase the efficiency and accuracy of dam inspection by incorporating remote sensing techniques into field-based monitoring programs. The methodology focuses on New York State and places emphasis on readily available remotely sensed data aerial photographs and Landsat data. Aerial photographs are employed in establishing a state-wide data base, referenced on county highway and U.S. Geological Survey 1:24,000 scale, topographic maps. Data base updates are conducted by county or region, using aerial photographs or Landsat as a primary source of information. Field investigations are generally limited to high-hazard or special problem dams, or to dams which cannot be assessed adequately with aerial photographs. Although emphasis is placed on available data, parameters for acquiring new aircraft data for assessing dam condition are outlined. Large scale (1:10,000) vertical, stereoscopic, color-infrared photography, flown during the spring or fall, is recommended.

Berger, J. P.↗

Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

Using Remotely Sensed Data for Climate Change Mitigation and Adaptation: A Collaborative Effort Between the Climate Change Adaptation Science Investigators Workgroup (CASI), NASA Johnson Space Center, and Jacobs Technology

With ever changing landscapes and environmental conditions due to human induced climate change, adaptability is imperative for the long-term success of facilities and Federal agency missions. To mitigate the effects of climate change, indicators such as above-ground biomass change must be identified to establish a comprehensive monitoring effort. Researching the varying effects of climate change on ecosystems can provide a scientific framework that will help produce informative, strategic and tactical policies for environmental adaptation. As a proactive approach to climate change mitigation, NASA tasked the Climate Change Adaptation Science Investigators Workgroup (CASI) to provide climate change expertise and data to Center facility managers and planners in order to ensure sustainability based on predictive models and current research. Generation of historical datasets that will be used in an agency-wide effort to establish strategies for climate change mitigation and adaptation at NASA facilities is part of the CASI strategy. Using time series of historical remotely sensed data is well-established means of measuring change over time. CASI investigators have acquired multispectral and hyperspectral optical and LiDAR remotely sensed datasets from NASA Earth Observation Satellites (including the International Space Station), airborne sensors, and astronaut photography using hand held digital cameras to create a historical dataset for the Johnson Space Center, as well as the Houston and Galveston area. The raster imagery within each dataset has been georectified, and the multispectral and hyperspectral imagery has been atmospherically corrected. Using ArcGIS for Server, the CASI-Regional Remote Sensing data has been published as an image service, and can be visualized through a basic web mapping application. Future work will include a customized web mapping application created using a JavaScript Application Programming Interface (API), and inclusion of the CASI data for the NASA Johnson Space Center into a NASA-Wide GIS Institutional Portal.

Jagge, Amy↗

Observing orbital debris using space-based telescopes. I - Mission orbit considerations

In this paper, mission orbit considerations are addressed for using the Space Shuttle as a telescope platform for observing man-made orbital debris. Computer modeling of various electrooptical systems predicts that such a space-borne system will be able to detect particles as small as 1-mm diameter. The research is meant to support the development of debris- collision warning sensors through the acquisition of spatial distribution and spectral characteristics for debris and testing of detector combinations on a shuttle-borne telescopic experiment. The technique can also be applied to low-earth-orbit-debris environment monitoring systems. It is shown how the choice of mission orbit, season of launch, and time of day of launch may be employed to provide extended periods of favorable observing conditions.

Reynolds, Robert C.↗

Unattended Monitoring of HEU Production in Gaseous Centrifuge Enrichment Plants using Automated Aerosol Collection and Laser-based Enrichment Assay

Nuclear power is enjoying rapid growth as government energy policies and public demand shift toward low carbon energy production. Pivotal to the global nuclear power renaissance is the development and deployment of robust safeguards instrumentation that allows the limited resources of the IAEA to keep pace with the expansion of the nuclear fuel cycle. Undeclared production of highly enriched uranium (HEU) remains a primary proliferation concern for modern gaseous centrifuge enrichment plants (GCEPs), due to their massive separative work unit (SWU) processing power and comparably short cascade equilibrium timescale. The Pacific Northwest National Laboratory is developing an unattended safeguards instrument, combining continuous aerosol particulate collection with uranium isotope assay, to provide timely detection of HEU production within a GCEP. This approach is based on laser vaporization of aerosol particulates, followed by laser spectroscopy to characterize the uranium enrichment level. Our prior investigation demonstrated single-shot detection sensitivity approaching the femtogram range and relative isotope ratio uncertainty better than 10% using gadolinium as a surrogate for uranium. In this paper we present measurement results on standard samples containing traces of depleted, natural, and low enriched uranium, as well as measurements on aerodynamic size uranium particles mixed in background materials (e.g., dust, minerals, soils). Improvements and optimizations in the detection electronics, signal timing, calibration, and laser alignment have lead to significant improvements in detection sensitivity and enrichment accuracy, contributing to an overall reduction in the false alarm probability. The sample substrate media was also found to play a significant role in facilitating laser-induced vaporization and the production of energetic plasma conditions, resulting in ablation optimization and further improvements in the isotope abundance sensitivity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lack of Transmission of Foot-and-Mouth Disease Virus From Persistently Infected Cattle to Naïve Cattle Under Field Conditions in Vietnam

Foot-and-mouth disease (FMD), caused by FMD virus (FMDV; Aphthovirus, Picornaviridae), is a highly contagious and economically important disease of clovenhoofed domestic livestock and wildlife species worldwide. Subsequent to the clinical phase of FMD, a large proportion of FMDV-infected ruminants become persistently infected carriers, defined by detection of FMDV in oropharyngeal fluid (OPF) samples 28 days or more post-infection. The goal of this prospective study was to characterize the FMD carrier state in cattle subsequent to natural infection under typical husbandry practices in Vietnam. Ten persistently infected cattle on eight farms in the Long An province in southern Vietnam were monitored by monthly screening of serum and oropharyngeal fluid samples for 12 months. To assess transmission from FMDV carriers, 16 naïve cattle were intentionally brought into direct contact with the persistently infected animals for 6 months, and were monitored by clinical and laboratory methods. The restricted mean duration of the FMD carrier state was 27.7 months, and the rate of decrease of the proportion of carrier animals was 0.03 per month. There was no evidence of transmission to naïve animals throughout the study period. Additionally, there was no detection of FMDV infection or seroconversion in three calves born to carrier animals during the study. The force of infection for carrier-to-contact transmission was 0 per month, with upper 95% confidence limit of 0.064 per month. Phylogenetic analysis of viral protein 1 (VP1) coding sequences obtained from carriers indicated that all viruses recovered in this study belonged to the O/ME-SA/PanAsia lineage, and grouped phylogenetically with temporally and geographically related viruses. Analysis of within-host evolution of FMDV, based upon full-length open reading frame sequences recovered from consecutive samples from one animal, indicated that most of the nonsynonymous changes occurred in Lpro, VP2, and VP3 protein coding regions. This study suggests that the duration of FMDV persistent infection in cattle may be longer than previously recognized, but the risk of transmission is low. Additional novel insights are provided into within-host viral evolution under natural conditions in an endemic setting.

59 BASIC BIOLOGICAL SCIENCES↗

Mobile sensing of point-source gas emissions using Bayesian inference: An empirical examination of the likelihood function

This paper evaluates likelihood function forms for Bayesian inference of point-source gas emissions using a mobile sensor. Whereas Bayesian inference has been successfully used to estimate emission rates from time-averaged concentration data measured by stationary sensors, data collected by mobile sensors do not represent ensemble or time-averaged conditions. To examine the potential impact of this contrast, controlled release experiments were conducted with a mobile sensor measuring concentrations repeatedly along transverse cross sections of the downwind plumes. Experiments were conducted with measurements made at different downwind distances, different sensor heights, and with different obstacle states. An examination is made between two commonly-used likelihood functions, the Gaussian and the log-normal. For experiments conducted in the absence of obstacles, the Bayesian estimates using the log-normal likelihood function yield a much smaller bias than those based on the Gaussian likelihood function. This finding is consistent with the non-Gaussian nature of concentration fluctuations near a point-source. For experiments conducted in the presence of obstacles, the Bayesian inference based on the Gaussian likelihood function exhibits a better performance. This can be explained by the enhanced turbulent mixing due to the obstacle-introduced wake eddies. Overall, we find that the selection of the likelihood function can be physically related to the underlying conditions, and the proper selection is critical to ensure the performance of the Bayesian inference for source characterization using mobile sensing data.

54 ENVIRONMENTAL SCIENCES↗

Modeling and simulation of Ultrasonic Guided Waves propagation in the fluid-structure domain by a monolithic approach

The present study introduces the coupled multiphysics model as part of the structural health monitoring (SHM) system. In particular, the Ultrasonic Guided Waves (UGWs) propagation is tracked in order to identify the damage to the structure. For this purpose, a multiphysics mathematical model is proposed. The model constitutes a monolithically coupled system of acoustic and elastic wave equations (WpFSI problem) where the wave signal displacement measurements are analyzed as the UGWs propagates in the solid, fluid and their interface. The ultimate goal of this paper is to explore and develop the efficient numerical solution of the WpFSI problem using the finite element method. A detailed description of the modeling framework and conditions that facilitate the coupling is provided. To couple the displacement-based acoustic wave equations for the isothermal fluid with elastic wave equations for the Saint Venant-Kirchhoff material model, the present study uses a monolithic solution algorithm. In particular, at each time step, wave equations are transformed to a fixed reference configuration via the arbitrary Lagrangian-Eulerian (ALE) mapping and automatically adopt the boundary conditions from the previous time step. The implementation is accomplished via the finite element library deal.II (Goll et al., 2017) based software toolbox DOpElib (Bangerth et al., 2007) which provides modularized higher level algorithms. Beyond SHM systems, the model is relevant for problems from biomechanics and biomedicine, vibromechanics, poroelasticity as well as subsurface and porous media flow. Here, the model developed here serves as a first step towards the on-line SHM system modeling, where structural dynamics are accounted for.

42 ENGINEERING↗

Development of an MC&A toolbox for liquid-fueled molten salt reactors with online reprocessing (Final Report)

A critical barrier to the deployment of MSRs is the absence of a well-defined nuclear material control and accounting (MC&A) approach, a vital prerequisite to meet NRC licensing requirements as well as facilitating future international exports. Liquid-fueled MSR variants (especially those incorporating online refueling or reprocessing) present a unique set of challenges to traditional nuclear material control and accountancy. Unlike solid-fueled light-water reactors, traditional item-counting methods cannot be applied as an accountancy strategy. Rather, MC&A approaches to MSR variants (including both uranium and thorium fueled designs) are more analogous to bulk material handling facilities (e.g., enrichment and reprocessing); yet further complicating matters is the fact that fuel medium is also highly radioactive. Meanwhile, the space of MSRs covers a broad range of design parameters, including thermal and fast spectra designs; operation in actinide breeder or burner modes, choice of actinide fuel used (e.g., 235 U, 232 Th / 233 U, denatured 233 U, etc.), pool or loop-type configuration, and even different salt chemistry. Each of these design choices introduce significant challenges to MC&A approaches within MSR facilities. We propose to bridge this gap for liquid-fueled MSRs by developing a modular, component-based test framework for evaluating viable process monitoring and MC&A techniques specifically suited to liquid-fueled MSR system variants employing online refueling or reprocessing. This test platform will consist of a toolbox of independent process modules representing discrete physical units (such as the reactor core, off-gas processing, decay tanks, and actinide separation units), each with its own self-contained physics responsive to the input mass flow, along with appropriate measurement models that can be coupled to key flow points. These dynamic physical signatures thus afford the ability to test the viability and efficacy of potential accountancy techniques under the full range of reactor operating conditions. As process modules are connected via mass flows, the result is a reconfigurable, generic MSR mass flow model capable of serving as an MC&A test platform for a broad spectrum of possible MSR configurations. The resulting MSR MC&A toolbox will enable robust assessment of accountancy strategies for this unique facility type, including analysis of physical feedbacks arising both from depletion of the fuel over time as well as from potential off-normal events, including those introduced by equipment failures (e.g., a pump failure) as well as by malicious action (i.e., attempts to divert material). The proposed toolbox both addresses a critical needs area for the MPACT analysis toolkit while leveraging existing MPACT-sponsored tools, especially with respect to simulation of measurement and accountancy techniques for advanced fuel cycle facilities. Beyond enabling new analysis capabilities for MSR systems, the design of this toolbox will be to such to maximize compatibility with existing MPACT tools, such to enhance existing facility MC&A analysis capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/temperature/humidity (FIFH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/ temperature / humidity (FTH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗