Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronics packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

NWChem

Computational atomistic modeling has emerged as a powerful approach for fundamental studies in chemistry, materials science, geosciences, and biology. It has the ability to provide detailed insights into complex phenomena and over the years has grown into a powerful tool not only to validate experiment, but also to predict new phenomena. In order to harness computational modeling to the fullest, superior computational tools are required that not only offer a broad spectrum of capabilities, but are also capable of taking advantage of modern massively parallel computer architectures efficiently to solve real world problems. The NWChem program suite is an example along these lines. It offers a range of capabilities to perform first-principles electronic structure calculations on molecular and periodic systems, classical molecular dynamics simulations and hybrid QM/MM simulations that permits one to combine quantum and classical methods within a calculation. The code is designed to run on high-performance parallel supercomputers as well as conventional workstation clusters with the goal to provide scalable solutions for large scale atomistic simulations. It has been ported to almost all high-performance computing platforms, workstations, PCs running LINUX, as well as clusters of desktop platforms or workgroup servers. The package is scalable, both in its ability to treat large problems efficiently, and in its utilization of available parallel computing resources. The parallel framework for NWChem is provided by the Global Array (GA) toolkit developed at PNNL. NWChem is developed and maintained by the Environmental Molecular Sciences Laboratory (EMSL) located at the Pacific Northwest National Laboratory (PNNL) in Washington State. The latest release (version 6.0) of the code is distributed under the terms of the Educational Community License (ECL) version 2.0.

99 GENERAL AND MISCELLANEOUS↗

Stretchable Lithium-Ion Batteries Enabled by Device-Scaled Wavy Structure and Elastic-Sticky Separator

Fast developments and substantial achievements have been shaping the field of wearable electronic devices, resulting in the persistent requirement for stretchable lithium-ion batteries (LIBs). Despite recent progress in stretchable electrodes, stretching full batteries, including electrodes, separator, and sealing material, remains a great challenge. Here, a simple design concept for stretchable LIBs via a wavy structure at the full battery device scale is reported. All components including the package are capable of being reversibly stretched by folding the entire pouch cell into a wavy shape with polydimethylsiloxane filled in each valley region. In addition, the stretchable, sticky, and porous polyurethane/poly(vinylidene fluoride) membrane is adopted as a separator for the first time, which can maintain intimate contact between electrodes and separator to continuously secure ion pathway under dynamic state. Commercial cathode, anode, and package can be utilized in this rationally designed wavy battery to enable stretchability. The results indicate good electrochemical performances and long-term stability at repeatable release–stretch cycles. A high areal capacity of 3.6 mA h cm -2 and energy density of up to 172 W h L -1 can be achieved for the wavy battery. The promising results of the cost-effective wavy battery with high stretchability shed light on the development of stretchable energy storages.

25 ENERGY STORAGE↗

Simulating excited-state complex ensembles: Fluorescence and solvatochromism in amine-arene exciplexes

Exciplexes are excited-state complexes formed as a result of partial charge transfer from the donor to the acceptor species when one moiety of the donor–acceptor pair is electronically excited. The arene–amine exciplex formed between oligo-(p-phenylene) (OPP) and triethylamine (TEA) is of interest in the catalytic photoreduction of CO2 because it can compete with complete electron transfer to the OPP catalyst. Therefore, formation of the exciplex can hinder the generation of a radical anion OPP·− necessary for subsequent CO2 reduction. We report an implementation of a workflow automating quantum-chemistry calculations that generate and characterize an ensemble of structures to represent this exciplex state. We use FireWorks, Pymatgen, and Custodian Python packages for high-throughput ensemble generation. The workflow includes time-dependent density functional theory optimization, verification of excited-state minima, and exciplex characterization with natural transition orbitals, exciton analysis, excited-state Mulliken charges, and energy decomposition analysis. Fluorescence spectra computed for these ensembles using Boltzmann-weighted contributions of each structure agree better with experiment than our previous calculations based on a single representative exciplex structure [Kron et al., J. Phys. Chem. A 126, 2319–2329 (2022)]. The ensemble description of the exciplex state also reproduces an experimentally observed red shift of the emission spectrum of [OPP-4–TEA]* relative to [OPP-3–TEA]*. The workflow developed here streamlines otherwise labor-intensive calculations that would require significant user involvement and intervention.

Chemistry↗

Development of a uninterrupted power system: ac and dc to dc converter

This program covered the design, fabrication and testing of an advanced development model uninterrupted power system. The input and output requirements imposed on the power processor were specified such that the unit is electrically interchangeable with existing power systems used by the Federal Aviation Administration in installations which have a history of failure due to electrical transient conditions. Input power is from either of two single-phase ac power sources or batteries with electronic selection and transfer between power sources. Battery reconditioning is automatic when either ac source is present. The output power is rated at 84OW; the nominal output is 24V at 35A. Within the 84OW limit, the regulated output voltage is adjustable from 22V to 30Vdc. Protection against continuous overloading or short circuit is provided. The unit is packaged in a standard 19-inch rack mount configuration with 7-inch panel height. Controls are on the front panel with power input and output through connectors on the rear surface. Cooling is by free convection from fin areas located on the side and rear panels. The packaged unit weighs 52.8 lbs., which can be reduced significantly if a three-phase ac power source is used.

Cronin, D. L.↗

The H-Metaphor as a Guideline for Vehicle Automation and Interaction

Good design is not free of form. It does not necessarily happen through a mere sampling of technologies packaged together, through pure analysis, or just by following procedures. Good design begins with inspiration and a vision, a mental image of the end product, which can sometimes be described with a design metaphor. A successful example from the 20th century is the desktop metaphor, which took a real desktop as an orientation for the manipulation of electronic documents on a computer. Initially defined by Xerox, then refined by Apple and others, it could be found on almost every computer by the turn of the 20th century. This paper sketches a specific metaphor for the emerging field of highly automated vehicles, their interactions with human users and with other vehicles. In the introduction, general questions on vehicle automation are raised and related to the physical control of conventional vehicles and to the automation of some late 20th century vehicles. After some words on design metaphors, the H-Metaphor is introduced. More details of the metaphor's source are described and their application to human-machine interaction, automation and management of intelligent vehicles sketched. Finally, risks and opportunities to apply the metaphor to technical applications are discussed.

Flemisch, Frank O.↗

Structural Bus and Release Mechanisms on the ST5 Satellites: Summary and Status

The Space Technology 5 Mechanical System met the challenge of packaging a fully functional science and technology satellite system with its Deployer mechanism into a compact 0.07cu m volume. Three 25 kg satellites were orbited in constellation in March, 2006. The ST5 mechanical system is composed of 1) The Structural Bus; 2) Magnetometer Instrument Boom 3) Spacecraft Deployer Release Mechanism This system includes a highly integrated electronics enclosure as a multifunctional structure; a lightweight, magnetically clean Magnetometer Boom; the first use of Nitinol Shape-Memory Alloy trigger devices for deploying multiple spacecraft; an innovative compliant mount for the umbilical connector and a Deployer mechanism that imparts both separation velocity and mission spin rate to three constellation flying satellites These elements employed cutting-edge design and analysis tools, state-of-the-art testing facilities and proven engineering techniques to meet stringent performance criteria, enabling the mission s success.

Rossoni, Peter↗

Designing Energy-Efficient Quantum Computers Through Prediction and Reduction of Cooling Requirements for Cryogenic Electronics

Quantum computing has been identified as a “wild card” by the International Energy Agency in predicting future global data center energy usage. This is primarily because both uncertainty in the extent to which quantum computing will be adopted, and uncertainty in the power consumption of individual quantum data centers. Unlike the classical counterparts, quantum computers need to be maintained at near absolute zero, requiring energy-intensive cryogenic cooling systems. Therefore, as quantum computers scale up from existing 50 qubit technology demonstrations to the 10,000 to 100,000 qubit systems that will be able to solve complex problems, the energy consumption of both the electronics and the required cooling systems will also increase. To predict this scaling, this work analyzes the energy requirements for both computation and cooling of quantum hardware. We show that the energy requirements for cooling of quantum computers is determined by several computing system parameters, including the number and type of physical qubits, the operating temperature, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. The energy requirements can then be found based on thermal system parameters such as cooling efficiency and cryostat heat transfer. Analysis of these parameters shows that the energy required for cooling is significantly larger than that required for computation, a reversal from energy usage patterns seen in conventional computing. The results and discussions provide a road-map for creating energy efficient quantum computers through the selection of computer architectures and cryogenic system configurations that minimize cooling requirements.

energy efficiency↗

Data from Stewart et al. 2026 "Organic Colloid Composition in Variable-Redox Porewaters within a Mountainous Floodplain"

Redox gradients, often driven by changes in sediment moisture levels in porous, heterogeneous groundwater systems, create dynamic conditions that may promote the production and transport of colloids within natural waters. While much research has focused on the inorganic composition of colloids, the organic composition remains less well understood. Organic matter (OM) in colloids may associate with minerals, complex metal ions, and serve as an electron donor for microbial respiration; therefore, its composition is of high interest. We examined the composition of porewater OM along a redox gradient in a riparian soil located along the Slate River in Crested Butte, Colorado, USA as a function of depth (90, 130, 200, and 350 cm below ground surface). All depths were oxic to suboxic, except 200 cm, where the products of iron and sulfate reduction were observed concomitant with an increase in dissolved and/or colloidal OM, pH, alkalinity, and conductivity. We investigated the composition of porewater using correlated scanning transmission X-ray microscopy and transmission electron microscopy. We observed a change in the OM chemistry from carboxylate-rich at the 200 cm depth (where it was also enmeshed with non-crystalline iron) to phenol- and substituted-aromatic-rich at other depths. Radiocarbon dating revealed carbon in porewater at 200 cm was younger than depths above and below. Soil porewater can flow down into the underlaying gravel bed during baseflow conditions, thus we speculate whether riparian porewater could transport iron- and carboxylate-rich organic colloids into surrounding surface waters through the gravel bed conduit. This data package includes geochemical data (.csv) as a function of depth from porewaters in OBJ1. Measurements included are pH, conductivity, TOC, Fe concentration, sulfate concentration, dissolved oxygen. Additionally radiocarbon dating age of carbon in samples is provided. Additionally, this dataset contains metadata files (.csv) describing the methods, file contents, and column headers.

alpine floodplain↗

Xyce Parallel Electronic Simulator Users' Guide Version 6.7.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been designed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel com- puting platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandia's needs, including some radiation- aware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase -- a message passing parallel implementation -- which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. The information herein is subject to change without notice. Copyright c 2002-2017 Sandia Corporation. All rights reserved. Trademarks Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. All other trademarks are property of their respective owners. Contacts World Wide Web http://xyce.sandia.gov https://info.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only) Bug Reports (Sandia only) http://joseki-vm.sandia.gov/bugzilla http://morannon.sandia.gov/bugzilla

97 MATHEMATICS AND COMPUTING↗

Xyce Parallel Electronic Simulator Users Guide Version 6.2.

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been de- signed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel com- puting platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandia's needs, including some radiation- aware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase -- a message passing parallel implementation -- which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. Trademarks The information herein is subject to change without notice. Copyright c 2002-2014 Sandia Corporation. All rights reserved. Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Portions of the Xyce TM code are: Copyright c 2002, The Regents of the University of California. Produced at the Lawrence Livermore National Laboratory. Written by Alan Hindmarsh, Allan Taylor, Radu Serban. UCRL-CODE-2002-59 All rights reserved. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. Xyce 's expression library is based on that inside Spice 3F5 developed by the EECS Department at the University of California. The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. All other trademarks are property of their respective owners. Contacts Bug Reports (Sandia only) http://joseki.sandia.gov/bugzilla http://charleston.sandia.gov/bugzilla World Wide Web http://xyce.sandia.gov http://charleston.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only)

Keiter, Eric R.↗

Xyce Parallel Electronic Simulator Users Guide Version 6.4

This manual describes the use of the Xyce Parallel Electronic Simulator. Xyce has been de- signed as a SPICE-compatible, high-performance analog circuit simulator, and has been written to support the simulation needs of the Sandia National Laboratories electrical designers. This development has focused on improving capability over the current state-of-the-art in the following areas: Capability to solve extremely large circuit problems by supporting large-scale parallel com- puting platforms (up to thousands of processors). This includes support for most popular parallel and serial computers. A differential-algebraic-equation (DAE) formulation, which better isolates the device model package from solver algorithms. This allows one to develop new types of analysis without requiring the implementation of analysis-specific device models. Device models that are specifically tailored to meet Sandia's needs, including some radiation- aware devices (for Sandia users only). Object-oriented code design and implementation using modern coding practices. Xyce is a parallel code in the most general sense of the phrase -- a message passing parallel implementation -- which allows it to run efficiently a wide range of computing platforms. These include serial, shared-memory and distributed-memory parallel platforms. Attention has been paid to the specific nature of circuit-simulation problems to ensure that optimal parallel efficiency is achieved as the number of processors grows. Trademarks The information herein is subject to change without notice. Copyright c 2002-2015 Sandia Corporation. All rights reserved. Xyce TM Electronic Simulator and Xyce TM are trademarks of Sandia Corporation. Portions of the Xyce TM code are: Copyright c 2002, The Regents of the University of California. Produced at the Lawrence Livermore National Laboratory. Written by Alan Hindmarsh, Allan Taylor, Radu Serban. UCRL-CODE-2002-59 All rights reserved. Orcad, Orcad Capture, PSpice and Probe are registered trademarks of Cadence Design Systems, Inc. Microsoft, Windows and Windows 7 are registered trademarks of Microsoft Corporation. Medici, DaVinci and Taurus are registered trademarks of Synopsys Corporation. Amtec and TecPlot are trademarks of Amtec Engineering, Inc. Xyce 's expression library is based on that inside Spice 3F5 developed by the EECS Department at the University of California. The EKV3 MOSFET model was developed by the EKV Team of the Electronics Laboratory-TUC of the Technical University of Crete. All other trademarks are property of their respective owners. Contacts Bug Reports (Sandia only) http://joseki.sandia.gov/bugzilla http://charleston.sandia.gov/bugzilla World Wide Web http://xyce.sandia.gov http://charleston.sandia.gov/xyce (Sandia only) Email xyce@sandia.gov (outside Sandia) xyce-sandia@sandia.gov (Sandia only)

97 MATHEMATICS AND COMPUTING↗

NEST: a comprehensive model for scintillation yield in liquid xenon

Here, a comprehensive model for explaining scintillation yield in liquid xenon is introduced. We unify various definitions of work function which abound in the literature and incorporate all available data on electron recoil scintillation yield. This results in a better understanding of electron recoil, and facilitates an improved description of nuclear recoil. An incident gamma energy range of O(1 keV) to O(1 MeV) and electric fields between 0 and O(10 kV/cm) are incorporated into this heuristic model. We show results from a Geant4 implementation, but because the model has a few free parameters, implementation in any simulation package should be simple. We use a quasi-empirical approach, with an objective of improving detector calibrations and performance verification. The model will aid in the design and optimization of future detectors. This model is also easy to extend to other noble elements. In this paper we lay the foundation for an exhaustive simulation code which we call NEST (Noble Element Simulation Technique).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Paired organs--Should they be treated jointly or separately in internal dosimetry?

Purpose: Size, shape, and the position of paired organs are different in abdomen. However, the counterpart organs are conventionally treated jointly together in internal dosimetry. This study was performed to quantify the difference of specific absorbed fraction of organs in considering paired organs jointly like single organs or as two separate organs. Methods: Zubal phantom and GATE Monte Carlo package were used to calculate the SAF for the self-absorption and cross-irradiation of the lungs, kidneys, adrenal glands (paired organs), liver, spleen, stomach, and pancreas (single organs). The activity was assumed uniformly distributed in the organs, and simulation was performed for monoenergetic photons of 10, 50, 100, 500, 1000 keV and mono-energetic electrons of 350, 500, 690, 935, 1200 keV. Results: The results demonstrated that self-absorption of left and right counterpart organs may be different depending upon the differences in their masses. The cross-irradiations between left-to-right and right-to-left counterpart organs are always equal irrespective of difference in their masses. Cross-irradiation from the left and right counterpart organs to other organs are different (4-24 times in Zubal phantom) depending on the photon energy and organs. The irradiation from a single source organ to the left and right counterpart paired organs is always different irrespective of activity concentration. Conclusions: Left and right counterpart organs always receive different absorbed doses from target organs and deliver different absorbed doses to target organs. Therefore, in application of radiopharmaceuticals in which the dose to the organs plays a role, counterpart organs should be treated separately as two separate organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bio-medical flow sensor

A bio-medical flow sensor including a packageable unit of a bottle, tubing and hypodermic needle which can be pre-sterilized and is disposable. The tubing has spaced apart tubular metal segments. The temperature of the metal segments and fluid flow therein is sensed by thermistors and at a downstream location heat is input by a resistor to the metal segment by a control electronics. The fluids flow and the electrical power required for the resisto to maintain a constant temperature differential between the tubular metal segments is a measurable function of fluid flow through the tubing. The differential temperature measurement is made in a control electronics and also can be used to control a flow control valve or pump on the tubing to maintain a constant flow in the tubing and to shut off the tubing when air is present in the tubing.

Winkler, H. E.↗

Compact Low Power Avionics for the Europa Lander Concept and Other Missions to Ocean Worlds

This paper presents the results of NASA’s game-changing technology development entitled “Ultra Low Temperature Electronics” which represents a paradigm shift in spacecraft avionics development. The project has developed compact avionics technologies to address the Command & Data Handling (CDH), Power and Motor Control needs for mission concepts to ocean worlds such as a potential Europa Lander. We addressed this need by developing the key technologies necessary to develop a next generation compact avionics package. The key technologies that we developed significantly reduce the size, weight, power, and cost (SWAP-C) of the avionics package. These technologies will also allow extreme-environment missions to last longer in their environment by reducing the power and energy requirement to keep the avionics warm.

Bolotin, Gary↗

Sr{sub 1.98}Eu{sub 0.02}SiO{sub 4} luminescence whisker based on vapor-phase deposition: Facile synthesis, uniform morphology and enhanced luminescence properties

Highlights: • For the first time, it is possible to obtain Sr{sub 1.98}Eu{sub 0.02}SiO{sub 4} whisker. • The whiskers are smooth and uniform with L/D ratio over 50. • Durability and thermal stability of the whisker are enhanced. - Abstract: A high performance strontium silicate phosphor has been successfully synthesized though a facile vapor-phase deposition method. The product consists of single crystal whiskers which are smooth and uniform, and with a sectional equivalent diameter of around 5 μm; the aspect ratio is over 50 and no agglomeration can be observed. X-ray diffraction result confirmed that the crystal structure of the whisker was α’-Sr{sub 2}SiO{sub 4}. The exact chemical composition was Sr{sub 1.98}Eu{sub 0.02}SiO{sub 4} which was analyzed by energy dispersive spectrometer and inductively coupled plasma-mass spectrometer. The whisker shows broad green emission with peak at 523 nm ranging from 470 to 600 nm (excited at 370 nm). Compared with traditional Sr{sub 2}SiO{sub 4}:Eu phosphor, durability (at 85% humidity and 85 °C) and thermal stability of the whisker are obviously improved. Moreover, growth mechanism of the Sr{sub 1.98}Eu{sub 0.02}SiO{sub 4} whiskers is Vapor–Liquid–Solid. On a macro-scale, the product is still powder which makes it suitable for the current packaging process of WLEDs.

36 MATERIALS SCIENCE↗

Performance Analysis: Work Control Events Identified January - August 2010

This performance analysis evaluated 24 events that occurred at LLNL from January through August 2010. The analysis identified areas of potential work control process and/or implementation weaknesses and several common underlying causes. Human performance improvement and safety culture factors were part of the causal analysis of each event and were analyzed. The collective significance of all events in 2010, as measured by the occurrence reporting significance category and by the proportion of events that have been reported to the DOE ORPS under the ''management concerns'' reporting criteria, does not appear to have increased in 2010. The frequency of reporting in each of the significance categories has not changed in 2010 compared to the previous four years. There is no change indicating a trend in the significance category and there has been no increase in the proportion of occurrences reported in the higher significance category. Also, the frequency of events, 42 events reported through August 2010, is not greater than in previous years and is below the average of 63 occurrences per year at LLNL since 2006. Over the previous four years, an average of 43% of the LLNL's reported occurrences have been reported as either ''management concerns'' or ''near misses.'' In 2010, 29% of the occurrences have been reported as ''management concerns'' or ''near misses.'' This rate indicates that LLNL is now reporting fewer ''management concern'' and ''near miss'' occurrences compared to the previous four years. From 2008 to the present, LLNL senior management has undertaken a series of initiatives to strengthen the work planning and control system with the primary objective to improve worker safety. In 2008, the LLNL Deputy Director established the Work Control Integrated Project Team to develop the core requirements and graded elements of an institutional work planning and control system. By the end of that year this system was documented and implementation had begun. In 2009, training of the workforce began and as of the time of this report more than 50% of authorized Integration Work Sheets (IWS) use the activity-based planning process. In 2010, LSO independently reviewed the work planning and control process and confirmed to the Laboratory that the Integrated Safety Management (ISM) System was implemented. LLNL conducted a cross-directorate management self-assessment of work planning and control and is developing actions to respond to the issues identified. Ongoing efforts to strengthen the work planning and control process and to improve the quality of LLNL work packages are in progress: completion of remaining actions in response to the 2009 DOE Office of Health, Safety, and Security (HSS) evaluation of LLNL's ISM System; scheduling more than 14 work planning and control self-assessments in FY11; continuing to align subcontractor work control with the Institutional work planning and control system; and continuing to maintain the electronic IWS application. The 24 events included in this analysis were caused by errors in the first four of the five ISMS functions. The most frequent cause was errors in analyzing the hazards (Function 2). The second most frequent cause was errors occurring when defining the work (Function 1), followed by errors during the performance of work (Function 4). Interestingly, very few errors in developing controls (Function 3) resulted in events. This leads one to conclude that if improvements are made to defining the scope of work and analyzing the potential hazards, LLNL may reduce the frequency or severity of events. Analysis of the 24 events resulted in the identification of ten common causes. Some events had multiple causes, resulting in the mention of 39 causes being identified for the 24 events. The most frequent cause was workers, supervisors, or experts believing they understood the work and the hazards but their understanding was incomplete. The second most frequent cause was unclear, incomplete or confusing documents directing the work. Together, these two causes were mentioned 17 times and contributed to 13 of the events. All of the events with the cause of ''workers, supervisors, or experts believing they understood the work and the hazards but their understanding was incomplete'' had this error in the first two ISMS functions: define the work and analyze the hazard. This means that these causes result in the scope of work being ill-defined or the hazard(s) improperly analyzed. Incomplete implementation of these functional steps leads to the hazards not being controlled. The causes are then manifested in events when the work is conducted. The process to operate safely relies on accurately defining the scope of work. This review has identified a number of examples of latent organizational weakness in the execution of work control processes.

99 GENERAL AND MISCELLANEOUS↗