Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Final Report for CCS Cross-Layer Reliability Visioning Study

The geometric rate of improvement of transistor size and integrated circuit performance known as Moore's Law has been an engine of growth for our economy, enabling new products and services, creating new value and wealth, increasing safety, and removing menial tasks from our daily lives. Affordable, highly integrated components have enabled both life-saving technologies and rich entertainment applications. Anti-lock brakes, insulin monitors, and GPS-enabled emergency response systems save lives. Cell phones, internet appliances, virtual worlds, realistic video games, and mp3 players enrich our lives and connect us together. Over the past 40 years of silicon scaling, the increasing capabilities of inexpensive computation have transformed our society through automation and ubiquitous communications. Looking forward, increasing unpredictability threatens our ability to continue scaling integrated circuits at Moore's Law rates. As the transistors and wires that make up integrated circuits become smaller, they display both greater differences in behavior among devices designed to be identical and greater vulnerability to transient and permanent faults. Conventional design techniques expend energy to tolerate this unpredictability by adding safety margins to a circuit's operating voltage, clock frequency or charge stored per bit. However, the rising energy costs needed to compensate for increasing unpredictability are rapidly becoming unacceptable in today's environment where power consumption is often the limiting factor on integrated circuit performance and energy efficiency is a national concern. Reliability and energy consumption are both reaching key inflection points that, together, threaten to reduce or end the benefits of feature size reduction. To continue beneficial scaling, we must use a cross-layer, Jull-system-design approach to reliability. Unlike current systems, which charge every device a substantial energy tax in order to guarantee correct operation in spite of rare events, such as one high-threshold transistor in a billion or one erroneous gate evaluation in an hour of computation, cross-layer reliability schemes make reliability management a cooperative effort across the system stack, sharing information across layers so that they only expend energy on reliability when an error actually occurs. Figure 1 illustrates an example of such a system that uses a combination of information from the application and cheap architecture-level techniques to detect errors. When an error occurs, mechanisms at higher levels in the stack correct the error, efficiently delivering correct operation to the user in spite of errors at the device or circuit levels. In the realms of memory and communication, engineers have a long history of success in tolerating unpredictable effects such as fabrication variability, transient upsets, and lifetime wear using information sharing, limited redundancy, and cross-layer approaches that anticipate, accommodate, and suppress errors. Networks use a combination of hardware and software to guarantee end-toend correctness. Error-detection and correction codes use additional information to correct the most common errors, single-bit transmission errors. When errors occur that cannot be corrected by these codes, the network protocol requests re-transmission of one or more packets until the correct data is received. Similarly, computer memory systems exploit a cross-layer division of labor to achieve high performance with modest hardware. Rather than demanding that hardware alone provide the virtual memory abstraction, software page-fault and TLB-miss handlers allow a modest piece of hardware, the TLB, to handle the common-case operations on a cyc1e-by-cycle basis while infrequent misses are handled in system software. Unfortunately, mitigating logic errors is not as simple or as well researched as memory or communication systems. This lack of understanding has led to very expensive solutions. For example, triple-modular redundancy masks errors by triplicating computations in either time or area. This mitigation methods imposes a 200% increase in energy consumption for every operation, not just the uncommon failure cases. At a time when computation is rapidly becoming part of our critical civilian and military infrastructure and decreasing costsfor computation are fueling our economy and our well being, we cannot afford increasingly unreliable electronics or a stagnation in capabilities per dollar, watt, or cubic meter. If researchers are able to develop techniques that tolerate the growing unpredictability of silicon devices, Moore's Law scaling should continue until at least 2022. During this 12-year time period, transistors, which are the building blocks of electronic devices, will scale their dimensions (feature sizes) from 45nm to 4.5nm.

99 GENERAL AND MISCELLANEOUS↗

Preclinical evaluation of novel urinary biomarkers of cadmium nephrotoxicity

As a result of the widespread use of Cd in industry and its extensive dissemination in the environment, there has been considerable interest in the identification of early biomarkers of Cd-induced kidney injury. Kim-1 is a transmembrane glycoprotein that is not detectable in normal kidney, but is up-regulated and shed into the urine following ischemic or nephrotoxic injury. Recent studies utilizing a sub-chronic model of Cd exposure in the rat have shown that Kim-1 is an early urinary marker of Cd-induced kidney injury. Kim-1 was detected in the urine 4-5 weeks before the onset of proteinuria and 1-3 weeks before the appearance of urinary metallothionein and Clara cell protein 16, which are standard markers of Cd nephrotoxicity. In the present study, we have compared the time course for the appearance of Kim-1 in the urine with the time course for the appearance of alpha glutathione-S-transferase ({alpha}-GST), N-acetyl-{beta}-D-glucose amidase (NAG) and Cd, each of which have been used or proposed as urinary markers of Cd nephrotoxicity. Adult male Sprague-Dawley rats were given daily subcutaneous injections of 0.6 mg (5.36 {mu}moles)/kg Cd, 5 days per week for up to 12 weeks. One day each week, 24 h urine samples were collected and analyzed for protein, creatinine and the various markers. The results showed that significant levels of Kim-1 appeared in the urine as early as 6 weeks into the treatment protocol and then continued to rise for the remainder of the 12 week treatment period. By contrast, significant levels of {alpha}-GST and NAG did not appear in the urine until 8 and 12 weeks, respectively, while proteinuria was not evident until 10 weeks. The urinary excretion of Cd was below the level of detection until week 4 and then showed a slow, linear increase over the next 6 weeks before increasing markedly between weeks 10 and 12. These results provide additional evidence that Kim-1 is a sensitive biomarker of the early stages of Cd-induced proximal tubule injury.

60 APPLIED LIFE SCIENCES↗

A comparison of adiabatic shear bands in wrought and additively manufactured 316L stainless steel using nanoindentation and electron backscatter diffraction

The resistance of stainless steels to shear localization is dependent on processing and microstructure. The amount of research evaluating the shear response of additively manufactured (AM) stainless steels compared to traditionally manufactured ones is limited. To address this gap, experiments were performed on directed energy deposition AM as-built and wrought 316L stainless steel using a forced shear technique with a hat-shaped specimen and a Split-Hopkinson pressure bar. The resulting adiabatic shear bands were characterized with electron backscatter diffraction (EBSD) and nanoindentation to quantify the changes in microstructure and deformation hardening across shear band regions and between the wrought and AM materials. Despite significant differences between the wrought and AM materials including the forced shear response, the postmortem states of work hardening due to the shear band deformation are nearly the same. The maximum nanoindentation stresses occurred in the shear band center with similar magnitudes and only minor differences away from the shear band. Although EBSD data cannot be resolved in the shear band center, misorientation trends, particularly grain reference orientation deviation, were found to closely resemble nanoindentation trends. In conclusion, the combination of EBSD misorientation and nanoindentation, which are linked through changes in dislocation density, is a viable protocol to quantify local changes to macroscopically applied deformation.

36 MATERIALS SCIENCE↗

Phase 2 Study of Docetaxel, Cisplatin, and Concurrent Radiation for Technically Resectable Stage III-IV Squamous Cell Carcinoma of the Head and Neck

Purpose: We investigated the efficacy and safety of weekly low-dose docetaxel and cisplatin therapy concurrent with conventionally fractionated radiation in patients with technically resectable stage III-IV squamous cell carcinoma of the head and neck. Methods and Materials: Between March 2004 and October 2011, we enrolled 117 patients, of whom 116 were analyzable (43 had oropharyngeal cancer, 54 had hypopharyngeal cancer, and 19 had laryngeal cancer), and 85 (73%) had stage IV disease. Radiation consisted of 66 Gy in 33 fractions. Docetaxel, 10 mg/m{sup 2}, followed by cisplatin, 20 mg/m{sup 2}, administered on the same day were given once a week for 6 cycles. The primary endpoint was overall complete response (CR) rate after chemoradiation therapy. Human papillomavirus (HPV) DNA in oropharyngeal cancer was examined by PCR. Results: Of 116 patients, 82 (71%) completed treatment per protocol; 102 (88%) received the full radiation therapy dose; and 90 (78%) and 12 (10%) patients received 6 and 5 chemotherapy cycles, respectively. Overall CR rate was 71%. After median follow-up of 50.9 months (range: 15.6-113.9 months for surviving patients), 2-year and 4-year overall survival rates were 82% and 68%, respectively. Cumulative 2-year and 4-year local failure rates were 27% and 28%, respectively, whereas distant metastasis rates were 15% and 22%, respectively. HPV status in oropharyngeal cancer was not associated with treatment efficacy. Acute toxicity included grade 3 and 4 in-field mucositis in 73% and 5% of patients, respectively, whereas myelosuppression and renal injury were minimal. No patients died of toxicity. Feeding tube dependence in 8% and tracheostomy in 1% of patients were evident at 2 years postchemoradiation therapy in patients who survived without local treatment failure. Conclusions: Local control and survival with this regimen were satisfactory. Although acute toxicity, such as mucositis, was common, late toxicity, such as laryngoesophageal dysfunction, was minimal. Therapy using weekly low-dose docetaxel and cisplatin concurrent with radiation warrants further evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enabling High-Energy, High-Voltage Lithium-Ion Cells: Standardization of Coin-Cell Assembly, Electrochemical Testing, and Evaluation of Full Cells

Coin-cells are often the test format of choice for laboratories engaged in battery research and development as they provide a convenient platform for rapid testing of new materials on a small scale. However, reliable, reproducible data via the coin-cell format is inherently difficult, particularly in the full-cell configuration. In addition, statistical evaluation to prove the consistency and reliability of such data is often neglected. Herein we report on several studies aimed at formalizing physical process parameters and coin-cell construction related to full cells. Statistical analysis and performance benchmarking approaches are advocated as a means to more confidently track changes in cell performance. Finally, we show that trends in the electrochemical data obtained from coin-cells can be reliable and informative when standardized approaches are implemented in a consistent manner.

25 ENERGY STORAGE↗

Integrated Data Collection Analysis (IDCA) Program - Final Review September 12, 2012 at DHS

The Integrated Data Collection Analysis (IDCA) program conducted a final program review at the Department of Homeland Security on September 12, 2012. The review was focused on the results of the program over the complete performance period. A summary presentation delineating the accomplished tasks started the meeting, followed by technical presentations on various issues that arose during the performance period. The presentations were completed with a statistical evaluation of the testing results from all the participants in the IDCA Proficiency Test study. The meeting closed with a discussion of potential sources of funding for continuing work to resolve some of these technical issues. This effort, funded by the Department of Homeland Security (DHS), put the issues of safe handling of these materials in perspective with standard military explosives. The study added Small-Scale Safety and Thermal (SSST) testing results for a broad suite of different HMEs to the literature, and suggested new guidelines and methods to develop safe handling practices for HMEs. Each participating testing laboratory used identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results were compared among the laboratories and then compared to historical data from various sources. The testing performers involved were Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Naval Surface Warfare Center, Indian Head Division (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory, Tyndall AFB (AFRL/RXQL). These tests were conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Whole-House Solutions Case Study: Low-Cost Evaluation of Energy Savings at the Community Scale - Fresno, California

In this project, IBACOS partnered with builder Wathen-Castanos Hybrid Homes to develop a simple and low-cost methodology by which community-scale energy savings can be evaluated based on results at the occupied test house level.Research focused on the builder and trade implementation of a whole-house systems integrated measures package and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

Building America↗

Summary of Booster Development and Qualification Report

This report outlines booster development work done at Los Alamos National Laboratory from 2007 to present. The booster is a critical link in the initiation train of explosive assemblies, from complex devices like nuclear weapons to conventional munitions. The booster bridges the gap from a small, relatively sensitive detonator to an insensitive, but massive, main charge. The movement throughout the explosives development community is to use more and more insensitive explosive components. With that, more energy is needed out of the booster. It has to initiate reliably, promptly, powerfully and safely. This report is divided into four sections. The first provides a summary of a collaborative effort between LANL, LLNL, and AWE to identify candidate materials and uniformly develop a testing plan for new boosters. Important parameters and the tests required to measure them were defined. The nature of the collaboration and the specific goals of the participating partners has changed over time, but the booster development plan stands on its own merit as a complete description of the test protocol necessary to compare and qualify booster materials, and is discussed in its entirety in this report. The second section describes a project, which began in 2009 with the Department of Defense to develop replacement booster formulations for PBXN-7. Replacement of PBXN-7 was necessary because it contained Triaminotrinitrobenzene (TATB), which was becoming unavailable to the DoD and because it contained Cyclotrimethylenetrinitramine (RDX), which was sensitive and toxic. A LANL-developed explosive, Diaminoazoxyfurazan (DAAF), was an important candidate. This project required any replacement formulation be a drop-in replacement in existing munitions. This project was timely, in that it made use of the collaborative booster development project, and had the additional constraint of matching shock sensitivity. Additionally it needed to be a safety improvement, and a performance improvement, especially at cold temperatures. The requirements of this project necessitated novel test development and a different approach to ranking booster qualities. Results of this project have been documented to the DoD and the relevant portions are included within. The third section of this booster report outlines testing related to main charge initiation merit. Initiability can be evaluated by looking at critical diameter, run distance, and shock sensitivity. Once a booster is initiated, it needs to be powerful enough to initiate the main charge symmetrically and evenly. Main charge initiability is evaluated directly by observing detonation wave symmetry, curvature, and first break out over the surface of a charge. Furthermore it must be insensitive to accidents and insults, and safe and reliable across a range of temperatures. These effects, tests, and results will be discussed individually in the context of DAAF and other explosives similarly tested. The last section provides a conclusion and summary of our experimental work and recommendations for the path forward. References and additional supporting documentation and results are provided in the appendices at the end of this report.

36 MATERIALS SCIENCE↗

Analysis of Underground Storage Tanks System Materials to Increased Leak Potential Associated with E15 Fuel

The Energy Independence and Security Act (EISA) of 2007 was enacted by Congress to move the nation toward increased energy independence by increasing the production of renewable fuels to meet its transportation energy needs. The law establishes a new renewable fuel standard (RFS) that requires the nation to use 36 billion gallons annually (2.3 million barrels per day) of renewable fuel in its vehicles by 2022. Ethanol is the most widely used renewable fuel in the US, and its production has grown dramatically over the past decade. According to EISA and RFS, ethanol (produced from corn as well as cellulosic feedstocks) will make up the vast majority of the new renewable fuel requirements. However, ethanol use limited to E10 and E85 (in the case of flex fuel vehicles or FFVs) will not meet this target. Even if all of the E0 gasoline dispensers in the country were converted to E10, such sales would represent only about 15 billion gallons per year. If 15% ethanol, rather than 10% were used, the potential would be up to 22 billion gallons. The vast majority of ethanol used in the United States is blended with gasoline to create E10, that is, gasoline with up to 10% ethanol. The remaining ethanol is sold in the form of E85, a gasoline blend with as much as 85% ethanol that can only be used in FFVs. Although DOE remains committed to expanding the E85 infrastructure, that market will not be able to absorb projected volumes of ethanol in the near term. Given this reality, DOE and others have begun assessing the viability of using intermediate ethanol blends as one way to transition to higher volumes of ethanol. In October of 2010, the EPA granted a partial waiver to the Clean Air Act allowing the use of fuel that contains up to 15% ethanol for the model year 2007 and newer light-duty motor vehicles. This waiver represents the first of a number of actions that are needed to move toward the commercialization of E15 gasoline blends. On January 2011, this waiver was expanded to include model year 2001 light-duty vehicles, but specifically prohibited use in motorcycles and off-road vehicles and equipment. UST stakeholders generally consider fueling infrastructure materials designed for use with E0 to be adequate for use with E10, and there are no known instances of major leaks or failures directly attributable to ethanol use. It is conceivable that many compatibility issues, including accelerated corrosion, do arise and are corrected onsite and, therefore do not lead to a release. However, there is some concern that higher ethanol concentrations, such as E15 or E20, may be incompatible with current materials used in standard gasoline fueling hardware. In the summer of 2008, DOE recognized the need to assess the impact of intermediate blends of ethanol on the fueling infrastructure, specifically located at the fueling station. This includes the dispenser and hanging hardware, the underground storage tank, and associated piping. The DOE program has been co-led and funded by the Office of the Biomass Program and Vehicle Technologies Program with technical expertise from the Oak Ridge National Laboratory (ORNL) and the National Renewable Energy Laboratory (NREL). The infrastructure material compatibility work has been supported through strong collaborations and testing at Underwriters Laboratories (UL). ORNL performed a compatibility study investigating the compatibility of fuel infrastructure materials to gasoline containing intermediate levels of ethanol. These results can be found in the ORNL report entitled Intermediate Ethanol Blends Infrastructure Materials Compatibility Study: Elastomers, Metals and Sealants (hereafter referred to as the ORNL intermediate blends material compatibility study). These materials included elastomers, plastics, metals and sealants typically found in fuel dispenser infrastructure. The test fuels evaluated in the ORNL study were SAE standard test fuel formulations used to assess material-fuel compatibility within a relatively short timeframe. Initially, these material studies included test fuels of Fuel C, CE10a, CE17a, and CE25a. The CE17a test fuel was selected to represent E15 since surveys have shown that the actual ethanol upper limit can be as high as 17%. Later, CE50a and CE85a test fuels were added to the investigation and these results are being compiled for a follow-on report to be published in 2012. Fuel C was used as the baseline reference and is a 50:50 blend of isooctane and toluene. This particular composition was used to represent premium-grade gasoline and was also used as the base fuel for the ethanol blends, where it is denoted by 'C' in the fuel name. The level of ethanol is represented by the number following the letter E. Therefore a 10% blend of ethanol in Fuel C is written as CE10a, where 'a' represents an aggressive formulation of the ethanol that contains water, NaCl, acetic and sulfuric acids per the SAE J1681 protocol.

02 PETROLEUM↗

Toward a W4-F12 approach: Can explicitly correlated and orbital-based ab initio CCSD(T) limits be reconciled?

In the context of high-accuracy computational thermochemistry, the valence coupled cluster with all singles and doubles (CCSD) correlation component of molecular atomization energies presents the most severe basis set convergence problem, followed by the (T) component. In the present paper, we make a detailed comparison, for an expanded version of the W4-11 thermochemistry benchmark, between, on the one hand, orbital-based CCSD/AV{5,6}Z + d and CCSD/ACV{5,6}Z extrapolation, and on the other hand CCSD-F12b calculations with cc-pVQZ-F12 and cc-pV5Z-F12 basis sets. This latter basis set, now available for H–He, B–Ne, and Al–Ar, is shown to be very close to the basis set limit. Apparent differences (which can reach 0.35 kcal/mol for systems like CCl{sub 4}) between orbital-based and CCSD-F12b basis set limits disappear if basis sets with additional radial flexibility, such as ACV{5,6}Z, are used for the orbital calculation. Counterpoise calculations reveal that, while total atomization energies with V5Z-F12 basis sets are nearly free of BSSE, orbital calculations have significant BSSE even with AV(6 + d)Z basis sets, leading to non-negligible differences between raw and counterpoise-corrected extrapolated limits. This latter problem is greatly reduced by switching to ACV{5,6}Z core-valence basis sets, or simply adding an additional zeta to just the valence orbitals. Previous reports that all-electron approaches like HEAT (high-accuracy extrapolated ab-initio thermochemistry) lead to different CCSD(T) limits than “valence limit + CV correction” approaches like Feller-Peterson-Dixon and Weizmann-4 (W4) theory can be rationalized in terms of the greater radial flexibility of core-valence basis sets. For (T) corrections, conventional CCSD(T)/AV{Q,5}Z + d calculations are found to be superior to scaled or extrapolated CCSD(T)-F12b calculations of similar cost. For a W4-F12 protocol, we recommend obtaining the Hartree-Fock and valence CCSD components from CCSD-F12b/cc-pV{Q,5}Z-F12 calculations, but the (T) component from conventional CCSD(T)/aug’-cc-pV{Q,5}Z + d calculations using Schwenke’s extrapolation; post-CCSD(T), core-valence, and relativistic corrections are to be obtained as in the original W4 theory. W4-F12 is found to agree slightly better than W4 with ATcT (active thermochemical tables) data, at a substantial saving in computation time and especially I/O overhead. A W4-F12 calculation on benzene is presented as a proof of concept.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation

Purpose: Conventional (i.e., respiratory-correlated) 4DCT exploits the repetitive nature of breathing to provide an estimate of motion; however, it has limitations due to binning artifacts and irregular breathing in actual patient breathing patterns. The aim of this work was to evaluate the accuracy and image quality of a dynamic volume, CT approach (4D{sub vol}) using a 320-slice CT scanner to minimize these limitations, wherein entire image volumes are acquired dynamically without couch movement. This will be compared to the conventional respiratory-correlated 4DCT approach (RCCT). Methods: 4D{sub vol} CT was performed and characterized on an in-house, programmable respiratory motion phantom containing multiple geometric and morphological ''tumor'' objects over a range of regular and irregular patient breathing traces obtained from 3D fluoroscopy and compared to RCCT. The accuracy of volumetric capture and breathing displacement were evaluated and compared with the ground truth values and with the results reported using RCCT. A motion model was investigated to validate the number of motion samples needed to obtain accurate motion probability density functions (PDF). The impact of 4D image quality on this accuracy was then investigated. Dose measurements using volumetric and conventional scan techniques were also performed and compared. Results: Both conventional and dynamic volume 4DCT methods were capable of estimating the programmed displacement of sinusoidal motion, but patient breathing is known to not be regular, and obvious differences were seen for realistic, irregular motion. The mean RCCT amplitude error averaged at 4 mm (max. 7.8 mm) whereas the 4D{sub vol} CT error stayed below 0.5 mm. Similarly, the average absolute volume error was lower with 4D{sub vol} CT. Under irregular breathing, the 4D{sub vol} CT method provides a close description of the motion PDF (cross-correlation 0.99) and is able to track each object, whereas the RCCT method results in a significantly different PDF from the ground truth, especially for smaller tumors (cross-correlation ranging between 0.04 and 0.69). For the protocols studied, the dose measurements were higher in the 4D{sub vol} CT method (40%), but it was shown that significant mAs reductions can be achieved by a factor of 4-5 while maintaining image quality and accuracy. Conclusions: 4D{sub vol} CT using a scanner with a large cone-angle is a promising alternative for improving the accuracy with which respiration-induced motion can be characterized, particularly for patients with irregular breathing motion. This approach also generates 4DCT image data with a reduced total scan time compared to a RCCT scan, without the need for image binning or external respiration signals within the 16 cm scan length. Scan dose can be made comparable to RCCT by optimization of the scan parameters. In addition, it provides the possibility of measuring breathing motion for more than one breathing cycle to assess stability and obtain a more accurate motion PDF, which is currently not feasible with the conventional RCCT approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Assessment of Manual Ultrasonic Examinations Applied to Detect Flaws in Primary System Dissimilar Metal Welds at North Anna Power Station

PNNL conducted a technical assessment of the NDE issues and protocols that led to missed detections of several axially oriented flaws in a steam generator primary inlet dissimilar metal weld at North Anna Power Station, Unit 1 (NAPS-1). This particular component design exhibits a significant outside-diameter (OD) taper that is not included as a blind performance demonstration mock-up within the industry’s Performance Demonstration Initiative, administered by EPRI. For this reason, the licensee engaged EPRI to assist in the development of a technical justification to support the basis for a site-specific qualification. The service-induced flaws at NAPS-1 were eventually detected as a result of OD surface machining in preparation for a full structural weld overlay. The machining operation uncovered the existence of two through-wall flaws, based on the observance of primary water leaking from the dissimilar metal weld. A total of five axially oriented flaws were detected in varied locations around the weld circumference. The field volumetric examination that was conducted at NAPS-1 was a non-encoded, real-time manual ultrasonic examination. PNNL conducted both an initial assessment, and subsequently, a more rigorous technical evaluation (reported here), which has identified an array of NDE issues that may have led to the subject missed detections. These evaluations were performed through technical reviews and discussions with NRC staff, EPRI NDE Center personnel, industry and ISI vendor personnel, and ultrasonic transducer manufacturers, and laboratory tests, to better understand the underlying issues at North Anna.

cracks↗

Development of the HyStEP Device

With the introduction of more fuel cell electric vehicles (FCEVs) on U.S. roadways, especially in California, the need for available hydrogen refueling stations is growing. While funding from the California Energy Commission is helping to solve this problem, solutions need to be developed and implemented to help reduce the time to commission a hydrogen station. The current practice of hydrogen station acceptance can take months because each vehicle manufacturer conducts their own testing and evaluation. This process is not practical or sufficient to support the timely development of a hydrogen fueling station network. To address this issue, as part of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project Sandia National Laboratories and the National Renewable Energy Laboratory along with a team of stakeholders and contractor Powertech Labs has developed the Hydrogen Station Equipment Performance (HyStEP) Device. The HyStEP Device is intended to be a surrogate for FCEVs that can be used to collect data on hydrogen station fueling performance. The device includes three Type IV 70 MPa tanks capable of storing a total of 9 kg H2 that are instrumented with pressure and temperature sensors. The tanks can be used individually or in parallel to simulate small, medium, and large fuel systems. The tanks are connected to a 70 MPa receptacle equipped with pressure and temperature sensor as well as infrared communications integrated with a data acquisition, analysis, and control system. The HyStEP Device is capable of performing tests defined in the test method standard CSA HGV 4.3 and providing the data needed to ensure that hydrogen stations meet the fueling protocol standard SAE J2601-2014. These include IrDA communication tests, fault detection tests, and communication and non-communication fueling.

30 DIRECT ENERGY CONVERSION↗

Impact of Adding Concomitant Chemotherapy to Hyperfractionated Accelerated Radiotherapy for Advanced Head-and-Neck Squamous Cell Carcinoma

Purpose: To evaluate the feasibility and efficacy of a hyperfractionated accelerated radiotherapy (RT) schedule combined with concomitant chemotherapy (Cx) in patients with locally advanced head-and-neck squamous cell carcinoma. Methods and Materials: Between 2004 and 2007, a total of 90 patients with locoregionally advanced head-and-neck squamous cell carcinoma underwent irradiation according to a hybrid fractionation schedule consisting of 20 fractions of 2 Gy (once daily) followed by 20 fractions of 1.6 Gy (twice daily) to a total dose of 72 Gy. Concomitant Cx (cisplatinum 100 mg/m{sup 2}) was administered at the start of Weeks 1 and 4. Treatment outcome and toxicity were retrospectively compared with a previous patient group (n = 73) treated with the same schedule, but without concomitant Cx, between 2001 and 2004. Results: The locoregional control (LRC) rate was 70% after 2 years. Two-year overall and 2-year disease-free survival rates were 74% and 60%, respectively. In comparison with the RT-only group, an improvement of 15% in both LRC (p = 0.03) and overall survival (p = 0.09) was observed. All patients were treated to full radiation dose according to protocol, although the Cx schedule had to be adjusted in 12 patients. No acute Grade 4 or 5 toxicity was seen, but incidences of Grade 3 acute mucositis (74.5% vs. 50.7%; p = 0.002) and dysphagia (82.2% vs. 47.9%; p < 0.001) were significantly higher in the chemoradiotherapy group compared with patients treated with RT alone. Conclusion: With this chemoradiotherapy regimen, excellent LRC and survival rates were achieved, with acceptable acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preservation of rat hearts in subfreezing temperature isochoric conditions to – 8 °C and 78 MPa

Highlights: • A novel method of low-temperature organ preservation is tested using rat hearts. • Isochoric systems allow ice-free preservation at temperatures well below freezing. • Conventional heart preservation employs on-ice storage in atmospheric conditions. • Histological quality is improved in hearts preserved in a −4 °C isochoric system. Isochoric (constant volume) preservation at subfreezing temperatures is being investigated as a novel method for preserving cells and organs. This study is a first initial effort to evaluate the efficacy of this method for heart preservation, and to provide a preliminary outline of appropriate preservation parameters. To establish a baseline for further studies, rat hearts were preserved in a University of Wisconsin (UW) intracellular solution for one hour under isochoric conditions at: 0 °C (atmospheric pressure - 0.1 MPa), - 4 °C (41 MPa), - 6 °C (60 MPa) and – 8 °C (78 MPa). The viability of the heart was evaluated using Langendorff perfusion and histological examination. The physiological performance of hearts preserved at – 4 °C (41 MPa) was comparable to that of a heart preserved on ice at atmospheric pressure, with no statistically significant difference in histological injury score. However, hearts preserved at −4 °C displayed substantially reduced interstitial edema compared to hearts preserved by conventional hypothermic preservation in UW on ice at atmospheric pressure, suggesting significant protection from increased vascular permeability following preservation. Hearts preserved at – 6 °C (60 MPa) suffered injury from cellular swelling and extensive edema, and at – 8 °C (78 MPa) hearts experienced significant morphological disruption. To the best of our knowledge, this is the first publication showing that a mammalian organ can survive low subfreezing temperatures without the use of a cryoprotective additive. Lowering the preservation temperature reduces metabolism and improves preservation quality, and these results suggest that improvements in preservation are possible at subzero temperatures with low to moderate pressures observed at −4 °C. Notably, tissue damage was observed at lower temperatures (−6 °C or below) accompanying further elevation of pressure associated with isochoric preservation that may prove detrimental. Therefore, subfreezing temperature isochoric preservation protocols should optimize, a combination of temperature and pressure that will minimize the negative effects of elevated pressure while retaining the beneficial effect of lower temperatures and reduced metabolism.

60 APPLIED LIFE SCIENCES↗

A Retrospective Tiered Environmental Assessment of the Mount Storm Wind Energy Facility, West Virginia, USA

Bird and bat fatalities from wind energy projects are an environmental and public concern, with post-construction fatalities sometimes differing from predictions. Siting facilities in this context can be a challenge. In March 2012 the U.S. Fish and Wildlife Service (USFWS) released Land-based Wind Energy Guidelines to assess collision fatalities and other potential impacts to species of concern and their habitats to aid in siting and management. The Guidelines recommend a tiered approach for assessing risk to wildlife, including a preliminary site evaluation that may evaluate alternative sites, a site characterization, field studies to document wildlife and habitat and to predict project impacts, post construction studies to estimate impacts, and other post construction studies. We applied the tiered assessment framework to a case study site, the Mount Storm Wind Energy Facility in Grant County, West Virginia, USA, to demonstrate the use of the USFWS assessment approach, to indicate how the use of a tiered assessment framework might have altered outputs of wildlife assessments previously undertaken for the case study site, and to assess benefits of a tiered ecological assessment framework for siting wind energy facilities. The conclusions of this tiered assessment for birds are similar to those of previous environmental assessments for Mount Storm. This assessment found risk to individual migratory tree-roosting bats that was not emphasized in previous preconstruction assessments. Differences compared to previous environmental assessments are more related to knowledge accrued in the past 10 years rather than to the tiered structure of the Guidelines. Benefits of the tiered assessment framework include good communication among stakeholders, clear decision points, a standard assessment trajectory, narrowing the list of species of concern, improving study protocols, promoting consideration of population-level effects, promoting adaptive management through post-construction assessment and mitigation, and sharing information that can be used in other assessments.

17 WIND ENERGY↗

Application of Peracetic Acid in Poultry Processing: Effects of Treatment Dynamics and Emerging Risk of Resistance Development in Salmonella spp.

Nontyphoidal Salmonella is a leading cause of foodborne illness, with poultry representing a major source. Peracetic acid (PAA), a widely adopted antimicrobial in poultry processing, offers advantages over traditional disinfectants but has sparked interest in its combined use with other antimicrobials and potential resistance. This review evaluates the efficacy of PAA in mitigating Salmonella in combination with other food-grade antimicrobials, explores possible synergism, efficacy under varying treatment parameters, resistance development against PAA, and its role in resistance evolution. While PAA demonstrates broad-spectrum efficacy, its performance varies with environmental parameters; higher temperatures generally enhance antimicrobial action but also accelerate PAA degradation. Organic matter diminishes PAA efficacy by reactive quenching. Variability in concentration and contact time further influences outcomes. Despite its oxidative mode of action and presumed low risk for resistance, emerging studies indicate that Salmonella can develop adaptive tolerance and potential cross/coresistance following repeated or sublethal exposure to PAA. These adaptations may involve genetic upregulation of oxidative stress response pathways, efflux systems, and modifications in cell membrane integrity, raising concerns about the long-term sustainability of PAA use. Additionally, combinatorial treatments (e.g., PAA with UV-C, enzymes, or organic acids) show promise in enhancing efficacy while mitigating resistance risks. Despite recognition of PAA's safety and effectiveness, knowledge gaps remain regarding standardized resistance definitions, serotype-specific tolerance, and optimal intervention strategies in commercial settings. Therefore, there is a need for standardized testing protocols, robust studies on potential resistance, and further exploration of synergistic PAA applications to ensure sustained poultry product safety and public health protection.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Individual Dose Calculations with Use of the Revised Techa River Dosimetry System TRDS-2009D

An updated deterministic version of the Techa River Dosimetry System (TRDS-2009D) has been developed to estimate individual doses from external exposure and intake of radionuclides for residents living on the Techa River contaminated as a result of radioactive releases from the Mayak plutonium facility in 1949–1956. The TRDS-2009D is designed as a flexible system that uses, depending on the input data for an individual, various elements of system databases to provide the dosimetric variables requested by the user. Several phases are included in the computation schedule. The first phase includes calculations with use of a common protocol for all cohort members based on village-average-intake functions and external dose rates; individual data on age, gender and history of residence are included in the first phase. This phase results in dose estimates similar to those obtained with system TRDS-2000 used previously to derive risks of health effects in the Techa River Cohort. The second phase includes refinement of individual internal doses for those persons who have had body-burden measurements or exposure parameters specific to the household where he/she lived on the Techa River. The third phase includes summation of individual doses from environmental exposure and from radiological examinations. The results of TRDS-2009D dose calculations have demonstrated for the ETRC members on average a moderate increase in RBM dose estimates (34%) and a minor increase (5%) in estimates of stomach dose. The calculations for the members of the ETROC indicated similar small changes for stomach, but significant increase in RBM doses (400%). Individual-dose assessments performed with use of TRDS-2009D have been provided to epidemiologists for exploratory risk analysis in the ETRC and ETROC. These data provide an opportunity to evaluate the possible impact on radiogenic risk of such factors as confounding exposure (environmental and medical), changes in the Techa River source-term data and the change of the approach to individual internal dose estimation (90Sr-body burden measurements and family correlations vs. village averages). Our further plan is to upgrade the TRDS-2009D and to complete a stochastic version of the dosimetry system.

61 RADIATION PROTECTION AND DOSIMETRY↗