Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Assessment of Spatial Uncertainties in the Radiotherapy Process With the Novalis System

Purpose: The purpose of this study was to evaluate the accuracy of a new version of the ExacTrac X-ray (ETX) system with statistical analysis retrospectively in order to determine the tolerance of systematic components of spatial uncertainties with the Novalis system. Methods and Materials: Three factors of geometrical accuracy related to the ETX system were evaluated by phantom studies. First, location dependency of the detection ability of the infrared system was evaluated. Second, accuracy of the automated calculation by the image fusion algorithm in the patient registration software was evaluated. Third, deviation of the coordinate scale between the ETX isocenter and the mechanical isocenter was evaluated. From the values of these examinations and clinical experiences, the total spatial uncertainty with the Novalis system was evaluated. Results: As to the location dependency of the detection ability of the infrared system, the detection errors between the actual position and the detected position were 1% in translation shift and 0.1{sup o} in rotational angle, respectively. As to the accuracy of patient verification software, the repeatability and the coincidence of the calculation value by image fusion were good when the contrast of the X-ray image was high. The deviation of coordinates between the ETX isocenter and the mechanical isocenter was 0.313 {+-} 0.024 mm, in a suitable procedure. Conclusions: The spatial uncertainty will be less than 2 mm when suitable treatment planning, optimal patient setup, and daily quality assurance for the Novalis system are achieved in the routine workload.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the substantive effectiveness of SEA: Towards a better understanding

Evaluating the substantive effectiveness of strategic environmental assessment (SEA) is vital in order to know to what extent the tool fulfills its purposes and produces expected results. However, the studies that have evaluated the substantive effectiveness of SEA produce varying outcomes as regards the tool's contribution to decision-making and have used a variety of approaches to appraise its effectiveness. The aim of this article is to discuss the theoretical concept of SEA substantive effectiveness and to present a new approach that can be applied for evaluation studies. The SEA effectiveness evaluation framework that will be presented is composed of concepts of, and approaches to, SEA effectiveness derived from SEA literature and planning theory. Lessons for evaluation can be learned from planning theory in particular, given its long history of analyzing and understanding how sources of information and decisions affect (subsequent) decision-making. Key concepts of this new approach are 'conformance' and 'performance'. In addition, this article presents a systematic overview of process and context factors that can explain SEA effectiveness, derived from SEA literature. To illustrate the practical value of our framework for the assessment and understanding of substantive effectiveness of SEA, three Dutch SEA case studies are examined. The case studies have confirmed the usefulness of the SEA effectiveness assessment framework. The framework proved helpful in order to describe the cumulative influence of the three SEAs on decision-making and the ultimate plan. - Highlights: Black-Right-Pointing-Pointer A new framework to evaluate the substantive effectiveness of SEA is presented. Black-Right-Pointing-Pointer The framework is based on two key concepts: 'conformance' and 'performance.' Black-Right-Pointing-Pointer The practical applicability of the framework is demonstrated by three Dutch cases. Black-Right-Pointing-Pointer The framework allows for a more systematic understanding of SEA effectiveness. Black-Right-Pointing-Pointer Finally, this paper presents explanations for SEA effectiveness.

54 ENVIRONMENTAL SCIENCES↗

Propulsion Controlled Aircraft design and development

This paper describes the design, development, and ground testing of the propulsion controlled aircraft (PCA) flight control system. A backup flight control system which uses only engine thrust, the PCA system utilizes collective and differential thrust changes to steer an aircraft that experiences partial or complete failure of the hydraulically actuated control surfaces. The objective of the program was to investigate, in flight, the throttles-only control capability of the F-15, using manual control, and also an augmented PCA mode in which computer-controlled thrust was used for flight control. The objective included PCA operation in up-and-away flight and, if performance was adequate, a secondary objective to make actual PCA landings. The PCA design began with a feasibility study which evaluated many control law designs. The study was done using off-line control analysis, simulation, and on-line manned flight simulator tests. Control laws, cockpit displays, and cockpit controls were evaluated by NASA test pilots. A flight test baseline configuration was selected based on projected flight performance, applicability to transport and fighter aircraft, and funding costs. During the PCA software and hardware development, the initial design was updated as data became available from throttle-only flight experiments conducted by NASA on the F-15. This information showed basic airframe characteristics that were not observed in the F-15 flight simulator and resulted in several design changes. After the primary objectives of the PCA flight testing were accomplished, additional PCA modes of operation were developed and implemented. The evolution of the PCA system from the initial feasibility study, control law design, simulation, hardware-in-the-loop tests, pilot-in-the-loop tests, and ground tests is presented.

Wells, Edward A.↗

Geological storage of CO2 in sub-seafloor basalt: the CarbonSAFE pre-feasibility study offshore Washington State and British Columbia

The CarbonSAFE Cascadia project is conducting a pre-feasibility study to evaluate technical and nontechnical aspects of collecting and storing 50 MMT of CO2 in a safe, ocean basalt reservoir offshore from Washington State and British Columbia. Sub-seafloor basalts are very common on Earth and enable CO2 mineralization as a long-term storage mechanism, permanently sequestering the carbon in solid rock form. Our project goals include evaluation of this reservoir as an industrial-scale CO2 storage complex, developing potential source/transport scenarios, and conducting laboratory and modeling studies to evaluate the potential capacity of the reservoir, and completing an evaluation of economic, regulatory and project management risks. Potential scenarios include sources and transport options in USA and in Canada. The overall project network consists of a coordination team of researchers from collaborating academic institutions, subcontractors, and external participants. Lessons learned from this study at the Cascadia Basin location may be transferrable elsewhere around the globe.

basalt, carbon storage, Offshore CO2 Injection↗

Evaluation of Behavior and Survival of Fish Exposed to an Axial-Flow Hydrokinetic Turbine

Abstract Previous studies have evaluated fish injury and mortality at hydrokinetic (HK) turbines, but because these studies focused on the impacts of these turbines in situ they were unable to evaluate fish responses to controlled environmental characteristics (e.g., current velocity and light or dark conditions). In this study, we used juvenile hybrid Striped Bass (HSB; Striped Bass Morone saxatilis × White Bass M. chrysops; N = 620), Rainbow Trout Oncorhynchus mykiss (N = 3,719), and White Sturgeon Acipenser transmontanus (N = 294) in a series of laboratory experiments to (1) evaluate the ability of fish to avoid entrainment through an axial-flow HK turbine, (2) evaluate fish injury and survival associated with turbine entrainment, and (3) compare the effects of different HK turbines on fish. We found that the probability of turbine entrainment was species dependent and highest for HSB. Across species, current velocity influenced entrainment probability. Among entrained fish, observed survival rates were generally >0.95. The probability of injury for surviving entrained fish only differed from that for nonentrained fish for Rainbow Trout and in general was not >0.20. The probability of injury following entrainment was greater only for HSB, although there were no differences in injury rates between fish that were turbine entrained and those that were not, suggesting that injuries were not turbine related. Taking turbine entrainment, survival, and injury estimates together allowed us to estimate the probability of a randomly selected fish in a population proximate to an HK turbine surviving passage or remaining uninjured after passage. For species and current velocities for which there was a significant effect due to entrainment, we estimated, for instance, that HSB had a survival probability of 0.95 and that Rainbow Trout and White Sturgeon had a >0.99 probability of survival. Similarly, by combining these estimates with those from previous studies, we derived total passage survival probabilities >0.90 but generally approaching 1.00 across different HK turbine types, fish species, and fish lengths. Received May 14, 2014; accepted October 23, 2014

Amaral, Stephen V.↗

Clarifying Objectives and Results of Equivalent System Mass Analyses for Advanced Life Support

This paper discusses some of the analytical decisions that an investigator must make during the course of a life support system trade study. Equivalent System Mass (ESM) is often applied to evaluate trade study options in the Advanced Life Support (ALS) Program. ESM can be used to identify which of several options that meet all requirements are most likely to have lowest cost. It can also be used to identify which of the many interacting parts of a life support system have the greatest impact and sensitivity to assumptions. This paper summarizes recommendations made in the newly developed ALS ESM Guidelines Document and expands on some of the issues relating to trade studies that involve ESM. In particular, the following three points are expounded: 1) The importance of objectives: Analysis objectives drive the approach to any trade study, including identification of assumptions, selection of characteristics to compare in the analysis, and the most appropriate techniques for reflecting those characteristics. 2) The importance of results inferprefafion: The accuracy desired in the results depends upon the analysis objectives, whereas the realized accuracy is determined by the data quality and degree of detail in analysis methods. 3) The importance of analysis documentation: Documentation of assumptions and data modifications is critical for effective peer evaluation of any trade study. ESM results are analysis-specific and should always be reported in context, rather than as solitary values. For this reason, results reporting should be done with adequate rigor to allow for verification by other researchers.

Levri, Julie A.↗

SU-C-202-05: Pilot Study of Online Treatment Evaluation and Adaptive Re-Planning for Laryngeal SBRT

Purpose: We have instigated a phase I trial of 5-fraction stereotactic body radiotherapy (SBRT) for advanced-stage laryngeal cancer. We conducted this pilot dosimetric study to confirm the potential utility of online adaptive re-planning to preserve treatment quality. Methods: Ten cases of larynx cancer were evaluated. Baseline and daily SBRT treatment plans were generated per trial protocol. Daily volumetric images were acquired prior to every fraction of treatment. Reference simulation CT images were deformably registered to daily volumetric images using Eclipse. Planning contours were then deformably propagated to daily images. Reference SBRT plans were directly copied to calculate delivered dose distributions on deformed reference CT images. In-house software platform has been developed to calculate cumulative dose over a course of treatment in four steps: 1) deforming delivered dose grid to reference CT images using deformation information exported from Eclipse; 2) generating tetrahedrons using deformed dose grid as vertices; 3) resampling dose to a high resolution within every tetrahedron; 4) calculating dose-volume histograms. Our inhouse software was benchmarked with a commercial software, Mirada. Results: In all ten cases including 49 fractions of treatments, delivered daily doses were completely evaluated and treatment could be re-planned within 10 minutes. Prescription dose coverage of PTV was less than intended in 53% of fractions of treatment (mean: 94%, range: 84%–98%) while minimum coverage of CTV and GTV was 94% and 97%, respectively. Maximum bystander point dose limits to arytenoids, parotids, and spinal cord remained respected in all cases, although variances in carotid artery doses were observed in a minority of cases. Conclusion: Although GTV and CTV coverage is preserved by in-room 3D image guidance of larynx SBRT, PTV coverage can vary significantly from intended plans. Online adaptive treatment evaluation and re-planning is potentially necessary and our procedure is clinically applicable to fully preserve treatment quality. This project is supported by CPRIT Individual Investigator Research Award RP150386.

60 APPLIED LIFE SCIENCES↗

Industrial Energy Assessment Training Effectiveness Evaluation: An Eye-Tracking Study

It is essential to understand the effectiveness of any training program so it can be improved accordingly. Various studies have applied standard metrics for the evaluation of visual behavior to recognize the areas of interest that attract individuals’ attention as there is a high correlation between attentional behavior and where one is focusing on. However, through reviewing the literature, we believe that studies that applied eye-tracking technologies for training purposes are still limited, especially in the industrial energy assessment training field. In this paper, the effectiveness of industrial energy assessment training was quantitatively evaluated by measuring the attentional allocation of trainees using eye-tracking technology. Moreover, this study identifies the areas that require more focus based on evaluating the performance of subjects after receiving the training. Additionally, this research was conducted in a controlled environment to remove the distractions that may be caused by environmental factors to only concentrate on variables that influence the learning behavior of subjects. The experiment results showed that after receiving the training, the subjects’ performance in energy assessment was significantly improved in two areas: production, and recycling and waste management, and the designed training program enhanced the knowledge of participants in identifying energy-saving opportunities to the knowledge level of experienced participants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cockpit Adaptive Automation and Pilot Performance

The introduction of high-level automated systems in the aircraft cockpit has provided several benefits, e.g., new capabilities, enhanced operational efficiency, and reduced crew workload. At the same time, conventional 'static' automation has sometimes degraded human operator monitoring performance, increased workload, and reduced situation awareness. Adaptive automation represents an alternative to static automation. In this approach, task allocation between human operators and computer systems is flexible and context-dependent rather than static. Adaptive automation, or adaptive task allocation, is thought to provide for regulation of operator workload and performance, while preserving the benefits of static automation. In previous research we have reported beneficial effects of adaptive automation on the performance of both pilots and non-pilots of flight-related tasks. For adaptive systems to be viable, however, such benefits need to be examined jointly in the context of a single set of tasks. The studies carried out under this project evaluated a systematic method for combining different forms of adaptive automation. A model for effective combination of different forms of adaptive automation, based on matching adaptation to operator workload was proposed and tested. The model was evaluated in studies using IFR-rated pilots flying a general-aviation simulator. Performance, subjective, and physiological (heart rate variability, eye scan-paths) measures of workload were recorded. The studies compared workload-based adaptation to to non-adaptive control conditions and found evidence for systematic benefits of adaptive automation. The research provides an empirical basis for evaluating the effectiveness of adaptive automation in the cockpit. The results contribute to the development of design principles and guidelines for the implementation of adaptive automation in the cockpit, particularly in general aviation, and in other human-machine systems. Project goals were met or exceeded. The results of the research extended knowledge of automation-related performance decrements in pilots and demonstrated the positive effects of adaptive task allocation. In addition, several practical implications for cockpit automation design were drawn from the research conducted. A total of 12 articles deriving from the project were published.

Parasuraman, Raja↗

Dosimetric effects of rotational output variation and x-ray target degradation on helical tomotherapy plans

In this study, two potential sources of IMRT delivery error have been identified for helical tomotherapy delivery using the HiART system (TomoTherapy, Inc., Madison, WI): Rotational output variation and target degradation. The HiArt system is known to have output variation, typically about {+-}2%, due to the absence of a dose servo system. On the HiArt system, x-ray target replacement is required approximately every 10-12 months due to target degradation. Near the end of target life, the target thins and causes a decrease in the beam energy and a softening of the beam profile at the lateral edges of the beam. The purpose of this study is to evaluate the dosimetric effects of rotational output variation and target degradation by modeling their effects and incorporating them into recalculated treatment plans for three clinical scenarios: Head and neck, partial breast, and prostate. Models were created to emulate both potential sources of error. For output variation, a model was created using a sine function to match the amplitude ({+-}2%), frequency, and phase of the measured rotational output variation data. A second model with a hypothetical variation of {+-}7% was also created to represent the largest variation that could exist without violating the allowable dose window in the delivery system. A measured beam profile near the end of target life was used to create a modified beam profile model for the target degradation. These models were then incorporated into the treatment plan by modifying the leaf opening times in the delivery sinogram. A new beam model was also created to mimic the change in beam energy seen near the end of target life. The plans were then calculated using a research version of the PLANNED ADAPTIVE treatment planning software from TomoTherapy, Inc. Three plans were evaluated in this study: Head and neck, partial breast, and prostate. The D{sub 50} of organs at risk, the D{sub 95} for planning target volumes (PTVs), and the local dose difference were used to evaluate the changes in the modified treatment plans. Dosimetric effects from rotational variation were found to be low (less than 1%) for a typical variation of {+-}2%. Even using a variation of {+-}7%, DVH values and dose distributions were altered by less than 2% for all scenarios. The dosimetric effects of target degradation were found to be slightly more significant. For a model using data taken just before target failure, dosimetric differences of 2%-4% were observed in the recalculated plans when compared to the original plans. The largest effects (up to 4.5%) were observed for PTVs that were located at deeper depths as seen in the prostate plan. Overall, the recalculated plans show that the dosimetric effects of rotational variation and target degradation are on the order of 1%-4% for helical tomotherapy on the HiART system and do not pose a risk for significant deviations from the original treatment plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of dual nitrogen and phosphorus additions on nutrient uptake and saturation kinetics in a forested headwater stream

Nitrogen (N) and phosphorus (P) can limit autotrophic and heterotrophic metabolism in lotic ecosystems, yet most studies that evaluate biotic responses to colimitation focus on patch-scale (e.g., nutrient diffusing substrata) rather than stream-scale responses. In this study, we evaluated the effects of single and dual N and P additions on ambient nutrient uptake rates and saturation kinetics during two biologically contrasting seasons (spring, autumn) in Walker Branch, a temperate forested headwater stream in Tennessee, USA. In each season, we used separate instantaneous pulse additions to quantify nutrient uptake rates and saturation kinetics of N (nitrate) and P (phosphate). We then used steady-state injections to elevate background stream water concentrations (to low and then high background concentrations) of one nutrient (e.g., N) and released instantaneous pulses of the other nutrient (e.g., P). We predicted that elevating the background concentration of one nutrient would result in a lower ambient uptake length and a higher maximum areal uptake rate of the other nutrient in this colimited stream. Our prediction held true in spring, as maximum areal uptake rate of N increased with elevated P concentrations from 185 µg m –2 min –1 (no added P) to 354 µg m –2 min –1 (high P). This pattern was not observed in autumn, as uptake rates of N were not measurable when P was elevated. Further, elevating background N concentration in either season did not significantly increase P uptake rates, likely because adsorption rather than biotic uptake dominated P dynamics. Laboratory P sorption assays demonstrated that Walker Branch sediments had a high adsorption capacity and were likely a sink for P during most pulse nutrient additions. Furthermore, it may be difficult to use coupled pulse nutrient additions to evaluate biotic uptake of N and P in streams with strong P adsorption potential. Future efforts should use dual nutrient addition techniques to investigate reach-scale coupled biogeochemical cycles (C–N–P, and other elemental cycles [e.g., Fe, Mo]) across seasons, biomes, and land-use types and over longer time periods.

54 ENVIRONMENTAL SCIENCES↗

The Performance of Radiographic Criteria for Bone Malignancy When Applied to Computed Tomography and Magnetic Resonance Imaging

The conventional radiologic features that differentiate benign from malignant bone lesions were originally described using radiography (x-ray [XR]). When evaluating sectional imaging studies such as magnetic resonance imaging (MRI) and computed tomography (CT), one may apply these principles to identify malignant bone lesions. The aim of this study was to evaluate the performances of these radiographic features for detecting malignity when applied to CT and MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of practical applications of H infinity control theory to the design of control systems for large space structures

The applicability of H infinity control theory to the problems of large space structures (LSS) control was investigated. A complete evaluation to any technique as a candidate for large space structure control involves analytical evaluation, algorithmic evaluation, evaluation via simulation studies, and experimental evaluation. The results of analytical and algorithmic evaluations are documented. The analytical evaluation involves the determination of the appropriateness of the underlying assumptions inherent in the H infinity theory, the determination of the capability of the H infinity theory to achieve the design goals likely to be imposed on an LSS control design, and the identification of any LSS specific simplifications or complications of the theory. The resuls of the analytical evaluation are presented in the form of a tutorial on the subject of H infinity control theory with the LSS control designer in mind. The algorthmic evaluation of H infinity for LSS control pertains to the identification of general, high level algorithms for effecting the application of H infinity to LSS control problems, the identification of specific, numerically reliable algorithms necessary for a computer implementation of the general algorithms, the recommendation of a flexible software system for implementing the H infinity design steps, and ultimately the actual development of the necessary computer codes. Finally, the state of the art in H infinity applications is summarized with a brief outline of the most promising areas of current research.

Irwin, R. Dennis↗

An analysis of energy deposition in a tissue equivalent proportional counter onboard the space shuttle

An improved prediction for space radiations in the lower earth orbits measured by the shuttle TEPC is obtained when energy loss straggling and chord length distribution of the detector are considered. A generalized analytic model is used to describe the energy deposition of direct ion interaction events in a micron-size detector. The transport calculation accounting for the shuttle configuration is accomplished by using a new version of HZETRN that has been extensively verified with laboratory and flight data. The agreement of predicted and measured lineal energy spectra is within 70% for the region above 2 keV/micrometer but within a factor of 2.3 underpredicted for the region below this value. The inclusion of indirect delta ray events in the model is needed before possible causes for the underprediction below 2 keV/micrometer can be assessed.

Flight Experiment↗

Removal of Burkholderia cepacia biofilms with oxidants

Iodine is used to disinfect the water system aboard US space shuttles and is the anticipated biocide for the international space station. Water quality on spacecraft must be maintained at the highest possible levels for the safety of the crew. Furthermore, the treatment process used to maintain the quality of water on research must be robust and operate for long periods with minimal crew intervention. Biofilms are recalcitrant and pose a major threat with regard to chronic contamination of spacecraft water systems. We measured the effectiveness of oxidizing biocides on the removal and regrowth of Burkholderia (Pseudomonas) cepacia biofilms. B. cepacia, isolated from the water distribution system of the space shuttle Discovery, was grown in continuous culture to produce a bacterial contamination source for biofilm formation and removal studies. A 10(7) CFU ml-1 B. cepacia suspension, in distilled water, was used to form biofilms on 3000 micrometers2 glass surfaces. Rates of attachment were measured directly with image analysis and were found to be 7.8, 15.2, and 22.8 attachment events h-1 for flow rates of 20.7, 15.2, and 9.8 ml min-1, respectively. After 18 h of formation, the B. cepacia biofilms were challenged with oxidants (ozone, chlorine, and iodine) and the rates of biofilm removal determined by image analysis. Fifty percent of the biofilm material was removed in the first hour of continous treatment with 24 mg l-1 chlorine or 2 mg l-1 ozone. Iodine (48 mg l-1) did not remove any measurable cellular material after 6 h continuous contact. After this first removal of biofilms by the oxidants, the surface was allowed to refoul and was again treated with the biocide. Iodine was the only compound that was unable to remove cellular debris from either primary or secondary biofilms. Moreover, treating primary biofilms with iodine increased the rate of formation of secondary biofilms, from 4.4 to 5.8 attachment events h-1. All the oxidants tested inactivated the B. cepacia associated with both primary and secondary biofilms. The amount of biocide needed to inactivate 50% of planktonic B. cepacia in 10 min at 25 degrees C was 8.4, 0.5, and 0.2 mg l-1 for iodine, chlorine, and ozone, respectively. The data suggest that iodine maynot be the best chemical for treating of biofilms when removal of cellular material is required.

NASA Discipline Environmental Health↗

Phase II Evaluation of Gefitinib in Patients With Newly Diagnosed Grade 4 Astrocytoma: Mayo/North Central Cancer Treatment Group Study N0074

Purpose: Amplification of the epidermal growth factor receptor (EGFR) gene represents one of the most frequent gene alterations in glioblastoma (GBM). In the current study, we evaluated gefitinib, a potent EGFR inhibitor, in the treatment of adults with newly diagnosed GBM. Methods and Materials: Ninety-eight patients (96 evaluable) were accrued between May 18, 2001, and August 2, 2002. All were newly diagnosed GBM patients who were clinically and radiographically stable/improved after radiation treatment (enrollment within 5 weeks of radiation completion). No prior chemotherapy was permitted. EGFR amplification/mutation, as assessed by fluorescence in situ hybridization and immunohistochemistry, was not required for treatment with gefitinib but was studied when tissues were available. Gefitinib was administered at 500 mg each day; for patients receiving dexamethasone or enzyme-inducing (CYP3A4) agents, dose was escalated to a maximum of 1,000 mg QD. Treatment cycles were repeated at 4-week intervals with brain magnetic resonance imaging at 8-week intervals. Results: Overall survival (OS; calculated from time of initial surgery) at 1 year (primary end point) with gefitinib was 54.2%, which was not statistically different compared with that of historical control population (48.9%, data from three previous Phase III North Central Cancer Treatment Group studies of newly diagnosed GBM patients). Progression-free survival (PFS) at 1 year post-RT (16.7%) was also not significantly different to that of historical controls (30.3%). Clinical outcome was not affected by EGFR status (amplification or vIII mutation). Fatigue (41%), rash (62%), and loose stools (58%) constituted the most frequent adverse events, the majority of these being limited to Grade 1/2. Of note, the occurrence of drug-related adverse effects, such as loose stools was associated with improved OS. Conclusions: In our evaluation of nearly 100 patients with newly diagnosed GBM, treatment with adjuvant gefitinib post-radiation was not associated with significant improvement in OS or PFS. However, patients who experienced gefitinib-associated adverse effects (rash/diarrhea) did demonstrate improved OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of novel biomarkers of nephrotoxicity in Cynomolgus monkeys treated with gentamicin

Most studies to evaluate kidney safety biomarkers have been performed in rats. This study was conducted in Cynomolgus monkeys in order to evaluate the potential usefulness of novel biomarkers of nephrotoxicity in this species. Groups of 3 males were given daily intramuscular injections of gentamicin, a nephrotoxic agent known to produce lesions in proximal tubules, at dose-levels of 10, 25, or 50 mg/kg/day for 10 days. Blood and 16-h urine samples were collected on Days − 7, − 3, 2, 4, 7, and at the end of the dosing period. Several novel kidney safety biomarkers were evaluated, with single- and multiplex immunoassays and in immunoprecipitation-LC/MS assays, in parallel to histopathology and conventional clinical pathology parameters. Treatment with gentamicin induced a dose-dependent increase in kidney tubular cell degeneration/necrosis, ranging from minimal to mild severity at 10 mg/kg/day, moderate at 25 mg/kg/day, and to severe at 50 mg/kg/day. The results showed that the novel urinary biomarkers, microalbumin, α1-microglobulin, clusterin, and osteopontin, together with the more traditional clinical pathology parameters, urinary total protein and N-acetyl-β-D-glucosaminidase (NAG), were more sensitive than blood urea nitrogen (BUN) and serum creatinine (sCr) to detect kidney injury in the monkeys given 10 mg/kg/day gentamicin for 10 days, a dose leading to an exposure which is slightly higher than the desired therapeutic exposure in clinics. Therefore, these urinary biomarkers represent non-invasive biomarkers of proximal tubule injury in Cynomolgus monkeys which may be potentially useful in humans. - Highlights: • Gentamicin induced kidney tubular cell degeneration/necrosis in Cynomolgus monkey • Urinary clusterin and osteopontin were sensitive biomarkers of kidney injury. • Microalbumin and α1-microglobulin in urine were also more sensitive than serum creatinine.

60 APPLIED LIFE SCIENCES↗