Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Flash Kα radiography of laser-driven solid sphere compression for fast ignition

Time-resolved compression of a laser-driven solid deuterated plastic sphere with a cone was measured with flash Kα x-ray radiography. A spherically converging shockwave launched by nanosecond GEKKO XII beams was used for compression while a flash of 4.51 keV Ti Kα x-ray backlighter was produced by a high-intensity, picosecond laser LFEX (Laser for Fast ignition EXperiment) near peak compression for radiography. Areal densities of the compressed core were inferred from two-dimensional backlit x-ray images recorded with a narrow-band spherical crystal imager. The maximum areal density in the experiment was estimated to be 87 ± 26 mg/cm{sup 2}. The temporal evolution of the experimental and simulated areal densities with a 2-D radiation-hydrodynamics code is in good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tutorial: Machine-Learning-Based CREASE-2D Analysis of 2D SAXS Profiles to Characterize Anisotropic Nanostructures in Soft Materials

We present a tutorial to guide users on how to extend the Computational Reverse Engineering Analysis of Scattering Experiments-2D (CREASE-2D) framework to interpret their experimental two-dimensional small-angle scattering (SAS) data from soft materials (e.g., polymers, peptide amphiphiles, biomolecular fibrils). Unlike most traditional SAS analysis approaches, which typically rely on azimuthally averaged onedimensional (1D) profiles, CREASE-2D utilizes the complete 2D scattering profile to reveal information about anisotropy in the structure. In past applications, CREASE has provided insights into complex structural features, including the cross-sectional shapes of assembled nanostructures and dispersity in these features, which are difficult to discern with existing analytical models. While (1D- ) CREASE has been applied to SANS and SAXS data, this tutorial shares the steps for implementing CREASE-2D using an example of a dipeptide solution system, for which we have SAXS data. We present details for these steps involved in using CREASE-2D to interpret SAXS profiles: how to preprocess SAXS data, define relevant structural features, generate three-dimensional real-space structures for specific values of these features, train a machine learning (ML) surrogate model to predict scattering profiles for given structural features, and optimize these features using genetic algorithms (GA). Then, we use these steps to interpret complex 2DSAXS data collected from dipeptide solutions that, in microscopy images, exhibit nanoscale structures that could be elliptical tubes/ flat tapes/cylinders or a combination of these cross sections. Open-source codes, computational hardware, and software requirements, as well as the strengths and limitations of this protocol, are also presented. We expect researchers working with (soft) biomaterials, peptide amphiphiles, amphiphilic polymer solutions, polymer nanocomposites, and blends of particles/polymers will find this CREASE-2D method and this tutorial of use.

CREASE↗

A Framework for International Collaboration on ITER Using Large-Scale Data Transfer to Enable Near-Real-Time Analysis

The global nature of the ITER project along with its projected ~ petabyte per day data generation presents a unique challenge, but also an opportunity for the fusion community to rethink, optimize, and enhance our scientific discovery process. Recognizing this, collaborative research with computational scientists was undertaken over the past several years to create a framework for large-scale data movement across wide-area networks (WANs), to enable global near-real time analysis of fusion data. This would broaden the available computational resources for analysis/simulation, and increase the number of researchers actively participating in experiments. An official demonstration of this framework for fast, large data transfer and real-time analysis was carried out between the KSTAR tokamak in Daejeon, Korea and PPPL in Princeton, USA. Streaming large data transfer, with near real-time movie creation and analysis of the KSTAR Electron Cyclotron Emission imaging (ECEI) data, was performed using the I/O framework ADIOS, and comparisons made at PPPL with simulation results from the XGC1 code. These demonstrations were made possible utilizing an optimized network configuration at PPPL, which achieved over 8.8 Gbps (88% utilization) in throughput tests from NFRI to PPPL. This demonstration showed the feasibility for large-scale data analysis of KSTAR data, and provides a nascent framework to enable use of globally distributed computational and personnel resources in pursuit of scientific knowledge from the ITER experiment.

43 PARTICLE ACCELERATORS↗

Herschel dust emission as a probe of starless cores mass: MCLD 123.5+24.9 of the polaris flare

We present newly processed archival Herschel images of molecular cloud MCLD 123.5+24.9 in the Polaris Flare. This cloud contains five starless cores. Using the spectral synthesis code Cloudy, we explore uncertainties in the derivation of column densities, and hence masses of molecular cores from Herschel data. We first consider several detailed grain models that predict far-infrared grain opacities. Opacities predicted by the models differ by more than a factor of two, leading to uncertainties in derived column densities by the same factor. Then we consider uncertainties associated with the modified blackbody fitting process used by observers to estimate column densities. For high column density clouds (N(H) ≫ 1 × 10{sup 22} cm{sup −2}), this fitting technique can underestimate column densities by about a factor of three. Finally, we consider the virial stability of the five starless cores in MCLD 123.5+24.9. All of these cores appear to have strongly sub-virial masses, assuming, as we argue, that {sup 13}CO line data provide reliable estimates of velocity dispersions. Evidently, they are not self-gravitating, so it is no surprise that they are starless.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Energy Survey Year 3 Results: Deep Field optical + near-infrared images and catalogue

ABSTRACT We describe the Dark Energy Survey (DES) Deep Fields, a set of images and associated multiwavelength catalogue (ugrizJHKs) built from Dark Energy Camera (DECam) and Visible and Infrared Survey Telescope for Astronomy (VISTA) data. The DES Deep Fields comprise 11 fields (10 DES supernova fields plus COSMOS), with a total area of ∼30 sq. deg. in ugriz bands and reaching a maximum i-band depth of 26.75 (AB, 10σ, 2 arcsec). We present a catalogue for the DES 3-yr cosmology analysis of those four fields with full 8-band coverage, totalling 5.88 sq. deg. after masking. Numbering 2.8 million objects (1.6 million post-masking), our catalogue is drawn from images coadded to consistent depths of r = 25.7, i = 25, and z = 24.3 mag. We use a new model-fitting code, built upon established methods, to deblend sources and ensure consistent colours across the u-band to Ks-band wavelength range. We further detail the tight control we maintain over the point-spread function modelling required for the model fitting, astrometry and consistency of photometry between the four fields. The catalogue allows us to perform a careful star–galaxy separation and produces excellent photometric redshift performance (NMAD = 0.023 at i < 23). The Deep-Fields catalogue will be made available as part of the cosmology data products release, following the completion of the DES 3-yr weak lensing and galaxy clustering cosmology work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ODDS: Real-Time Object Detection Using Depth Sensors on Embedded GPUs

Detecting objects that are carried when someone enters or exits a room is very useful for a wide range of smart building applications including safety, security, and energy efficiency. While there has been a significant amount of work on object recognition using large-scale RGB image datasets, RGB cameras are too privacy invasive in many smart building applications and they work poorly in the dark. Additionally, deep object detection networks require powerful and expensive GPUs. We propose a novel system that we call ODDS (Object Detector using a Depth Sensor) that can detect objects in real-time using only raw depth data on an embedded GPU, e.g., NVIDIA Jetson TX1. Hence, our solution is significantly less privacy invasive (even if the sensor is compromised) and less expensive, while maintaining a comparable accuracy with state of the art solutions. Specifically, we resort to training a deep convolutional neural network using raw depth images, with curriculum based learning to improve accuracy by considering the complexity and imbalance in object classes and developing a sparse coding based technique that speeds up the system ~2× with minimal loss of accuracy. Based on a complete implementation and real-world evaluation, we see ODDS achieve 80.14% mean average precision in object detection in real-time (5-6 FPS) on a Jetson TX1.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology

Purpose: Many centers aim to plan liver transarterial radioembolization (TARE) with dosimetry, even without CT-based attenuation correction (AC), or with unoptimized scatter correction (SC) methods. This work investigates the impact of presence vs absence of such corrections, and limited spatial resolution, on 3D dosimetry for TARE. Methods: Three voxelized phantoms were derived from CT images of real patients with different body sizes. Simulations of {sup 99m}Tc-SPECT projections were performed with the SIMIND code, assuming three activity distributions in the liver: uniform, inside a “liver’s segment,” or distributing multiple uptaking nodules (“nonuniform liver”), with a tumoral liver/healthy parenchyma ratio of 5:1. Projection data were reconstructed by a commercial workstation, with OSEM protocol not specifically optimized for dosimetry (spatial resolution of 12.6 mm), with/without SC (optimized, or with parameters predefined by the manufacturer; dual energy window), and with/without AC. Activity in voxels was calculated by a relative calibration, assuming identical microspheres and {sup 99m}Tc-SPECT counts spatial distribution. 3D dose distributions were calculated by convolution with {sup 90}Y voxel S-values, assuming permanent trapping of microspheres. Cumulative dose-volume histograms in lesions and healthy parenchyma from different reconstructions were compared with those obtained from the reference biodistribution (the “gold standard,” GS), assessing differences for D95%, D70%, and D50% (i.e., minimum value of the absorbed dose to a percentage of the irradiated volume). γ tool analysis with tolerance of 3%/13 mm was used to evaluate the agreement between GS and simulated cases. The influence of deep-breathing was studied, blurring the reference biodistributions with a 3D anisotropic gaussian kernel, and performing the simulations once again. Results: Differences of the dosimetric indicators were noticeable in some cases, always negative for lesions and distributed around zero for parenchyma. Application of AC and SC reduced systematically the differences for lesions by 5%–14% for a liver segment, and by 7%–12% for a nonuniform liver. For parenchyma, the data trend was less clear, but the overall range of variability passed from −10%/40% for a liver segment, and −10%/20% for a nonuniform liver, to −13%/6% in both cases. Applying AC, SC with preset parameters gave similar results to optimized SC, as confirmed by γ tool analysis. Moreover, γ analysis confirmed that solely AC and SC are not sufficient to obtain accurate 3D dose distribution. With breathing, the accuracy worsened severely for all dosimetric indicators, above all for lesions: with AC and optimized SC, −38%/−13% in liver’s segment, −61%/−40% in the nonuniform liver. For parenchyma, D50% resulted always less sensitive to breathing and sub-optimal correction methods (difference overall range: −7%/13%). Conclusions: Reconstruction protocol optimization, AC, SC, PVE and respiratory motion corrections should be implemented to obtain the best possible dosimetric accuracy. On the other side, thanks to the relative calibration, D50% inaccuracy for the healthy parenchyma from absence of AC was less than expected, while the optimization of SC was scarcely influent. The relative calibration therefore allows to perform TARE planning, basing on D50% for the healthy parenchyma, even without AC or with suboptimal corrections, rather than rely on nondosimetric methods.

60 APPLIED LIFE SCIENCES↗

Visualizing expanding warm dense matter heated by laser-generated ion beams

This PowerPoint presentation concluded with the following. We calculated the expected heating per atom and temperatures of various target materials using a Monte Carlo simulation code and SESAME EOS tables. We used aluminum ion beams to heat gold and diamond uniformly and isochorically. A streak camera imaged the expansion of warm dense gold (5.5 eV) and diamond (1.7 eV). GXI-X recorded all 16 x-ray images of the unheated gold bar targets proving that it could image the motion of the gold/diamond interface of the proposed target.

36 MATERIALS SCIENCE↗

Monte Carlo Study of Imaging Plate Response to Laser-Driven Aluminum Ion Beams

We measured the response of BAS-TR imaging plate (IP) to energetic aluminum ions up to 222 MeV, and compared it with predictions from a Monte Carlo simulation code using two different IP response models. Energetic aluminum ions were produced with an intense laser pulse, and the response was evaluated from cross-calibration between CR-39 track detector and IP energy spectrometer. For the first time, we obtained the response function of the BAS-TR IP for aluminum ions with a kinetic energy as high as 222 MeV. On close examination of the two IP response models, we confirm that the exponential model fits our experimental data better. Moreover, we find that the IP sensitivity in the exponential model is nearly constant in this energy range, suggesting that the response function can be determined even with little experimental data.

Won, Junho↗

New two-dimensional photon camera

A photon-sensitive camera, applicable to speckle imaging of astronomical sources, high-resolution spectroscopy of faint galaxies in a crossed-dispersion spectrograph, or narrow-band direct imaging of galaxies, is presented. The camera is shown to supply 8-bit by 8-bit photon positions (256 x 256 pixels) for as many as 10 to the 6th photons/sec with a maximum linear resolution of approximately 10 microns. The sequence of photon positions is recorded digitally with a VHS-format video tape recorder or formed into an immediate image via a microcomputer. The four basic elements of the camera are described in detail: a high-gain image intensifier with fast-decay output phosphor, a glass-prism optical-beam splitter, a set of Gray-coded masks, and a photomultiplier tube for each mask. The characteristics of the camera are compared to those of other photon cameras.

Papaliolios, C.↗

Randomization of dust-ejecta motions and the observed morphology of cometary heads

The computer code that has been used over years to study the dust-coma morphology of comets and to generate their synthetic images is upgraded by introducing two categories of random perturbations into the motions of dust particles ejected from discrete sources of activity on the nucleus surface. The new technique is applied to three types of morphological features: multiple concentric halos, a system of spiral jets, and a sunward fan-shaped coma. The results indicate that inclusion of random perturbations substantially enhances the capability for generating synthetic images that faithfully simulate the observed appearance of dust comets. By increasing the magnitude of perturbations in the synthetic images beyond a certain limit, it is possible to 'erase' morphological features characteristic of the ejection process. This implies that the lack of distinct morphology in the head of a comet cannot be interpreted as the absence of discrete sources of activity on the nucleus surface. The effects of varying random perturbations on the appearance of the computer-generated images are investigated in detail and the suspected major role that imperfect flow collimation (or flow divergence) in dust jets plays with regard to the observed coma morphology is discussed.

Sekanina, Zdenek↗

Accounting for Laminar Run & Trip Drag in Supersonic Cruise Performance Testing

An improved laminar run and trip drag correction methodology for supersonic cruise performance testing was derived. This method required more careful analysis of the flow visualization images which revealed delayed transition particularly on the inboard upper surface, even for the largest trip disks. In addition, a new code was developed to estimate the laminar run correction. Once the data were corrected for laminar run, the correct approach to the analysis of the trip drag became evident. Although the data originally appeared confusing, the corrected data are consistent with previous results. Furthermore, the modified approach, which was described in this presentation, extends prior historical work by taking into account the delayed transition caused by the blunt leading edges.

Goodsell, Aga M.↗

Software Suite to Support In-Flight Characterization of Remote Sensing Systems

A characterization software suite was developed to facilitate NASA's in-flight characterization of commercial remote sensing systems. Characterization of aerial and satellite systems requires knowledge of ground characteristics, or ground truth. This information is typically obtained with instruments taking measurements prior to or during a remote sensing system overpass. Acquired ground-truth data, which can consist of hundreds of measurements with different data formats, must be processed before it can be used in the characterization. Accurate in-flight characterization of remote sensing systems relies on multiple field data acquisitions that are efficiently processed, with minimal error. To address the need for timely, reproducible ground-truth data, a characterization software suite was developed to automate the data processing methods. The characterization software suite is engineering code, requiring some prior knowledge and expertise to run. The suite consists of component scripts for each of the three main in-flight characterization types: radiometric, geometric, and spatial. The component scripts for the radiometric characterization operate primarily by reading the raw data acquired by the field instruments, combining it with other applicable information, and then reducing it to a format that is appropriate for input into MODTRAN (MODerate resolution atmospheric TRANsmission), an Air Force Research Laboratory-developed radiative transport code used to predict at-sensor measurements. The geometric scripts operate by comparing identified target locations from the remote sensing image to known target locations, producing circular error statistics defined by the Federal Geographic Data Committee Standards. The spatial scripts analyze a target edge within the image, and produce estimates of Relative Edge Response and the value of the Modulation Transfer Function at the Nyquist frequency. The software suite enables rapid, efficient, automated processing of ground truth data, which has been used to provide reproducible characterizations on a number of commercial remote sensing systems. Overall, this characterization software suite improves the reliability of ground-truth data processing techniques that are required for remote sensing system in-flight characterizations.

Stanley, Thomas↗

Passive method to measure strength of turbulence

Disclosed is a method to passively measure and calculate the strength of turbulence via the index of refraction structure constant C.sub.n.sup.2 from video imagery gathered by an imaging device, such as a video camera. Processing may occur with any type computing device utilizing a processor executing machine executable code stored on memory. This method significantly simplifies instrumentation requirements, reduces cost, and provides rapid data output. This method combines an angle of arrival methodology, which provides scale factors, with a new spatial/temporal frequency domain method. As part of the development process, video imagery from high speed cameras was collected and analyzed. The data was decimated to video rates such that statistics could be computed and used to confirm that this passive method accurately characterizes the atmospheric turbulence. C.sub.n.sup.2 accuracy from this method compared well with scintillometer data through two full orders of magnitude and more capability is expected beyond this verification.

O'Neill, Mary Morabito↗

Passive method to measure strength of turbulence

Disclosed is a method to passively measure and calculate the strength of turbulence via the index of refraction structure constant Cn2 from video imagery gathered by an imaging device, such as a video camera. Processing may occur with any type computing device utilizing a processor executing machine executable code stored on memory. This method significantly simplifies instrumentation requirements, reduces cost, and provides rapid data output. This method combines an angle of arrival methodology, which provides scale factors, with a new spatial/temporal frequency domain method. As part of the development process, video imagery from high speed cameras was collected and analyzed. The data was decimated to video rates such that statistics could be computed and used to confirm that this passive method accurately characterizes the atmospheric turbulence. Cn2 accuracy from this method compared well with scintillometer data through two full orders of magnitude and more capability is expected beyond this verification.

O'Neill, Mary Morabito↗

MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection

Purpose: The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Methods: Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contours were selected in a spectral clustering manifold learning framework. This aids in clustering “similar” gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. Results: A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). Conclusions: An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold seeds are either correctly detected or a warning is raised for further manual intervention.

60 APPLIED LIFE SCIENCES↗

Preclinical investigation for developing injectable fiducial markers using a mixture of BaSO{sub 4} and biodegradable polymer for proton therapy

Purpose: The aim of this study is to investigate the use of mixture of BaSO{sub 4} and biodegradable polymer as an injectable nonmetallic fiducial marker to reduce artifacts in x-ray images, decrease the absorbed dose distortion in proton therapy, and replace permanent metal markers. Methods: Two samples were made with 90 wt. % polymer phosphate buffer saline (PBS) and 10 wt. % BaSO{sub 4} (B1) or 20 wt. % BaSO{sub 4} (B2). Two animal models (mice and rats) were used. To test the injectability and in vivo gelation, a volume of 200 μl at a pH 5.8 were injected into the Sprague-Dawley rats. After sacrificing the rats over time, the authors checked the gel morphology. Detectability of the markers in the x-ray images was tested for two sizes (diameters of 1 and 2 mm) for B1 and B2. Four samples were injected into BALB/C mice. The polymer mixed with BaSO{sub 4} transform from SOL at 20 °C with a pH of 6.0 to GEL in the living body at 37 °C with a pH of 7.4, so the size of the fiducial marker could be controlled by adjusting the injected volume. The detectability of the BaSO{sub 4} marker was measured in x-ray images of cone beam CT (CBCT), on-board imager [anterior–posterior (AP), lateral], and fluoroscopy (AP, lateral) using a Novalis-TX (Varian Medical Systems, Palo Alto, CA) repeatedly over 4 months. The volume, HU, and artifacts for the markers were measured in the CBCT images. Artifacts were compared to those of gold marker by analyzing the HU distribution. The dose distortion in proton therapy was computed by using a Monte Carlo (MC) code. A cylindrical shaped marker (diameter: 1 or 2 mm, length: 3 mm) made of gold, stainless-steel [304], titanium, and 20 wt. % BaSO{sub 4} was positioned at the center of the spread-out Bragg peak (SOBP) in parallel or perpendicular to the beam entrance. The dose distortion was measured on the depth dose profile across the markers. Results: Transformation to GEL and the biodegradation were verified. All BaSO{sub 4} markers could be detected in the CBCT. In the OBI and fluoroscopy images, all markers visible in the AP, but only B2(2 mm) could be identified in the lateral images. Changes of BaSO{sub 4} position were not detected in vivo (mice). The volume of the markers decreased by up to 65% and the HU increased by 22%, on average. The mean HU values around the B1, B2, and gold markers were 121.30 [standard deviation (SD): 54.86], 126.31 (SD: 62.13), and 1070.7 (SD: 235.16), respectively. The MC-simulated dose distortion for the BaSO{sub 4} markers was less than that of the commercially used markers. The dose reduction due to the gold marker was largest (15.05%) followed by stainless steel (7.92%) and titanium (6.92%). Dose reduction by B2 (2 mm) was 4.75% and 0.53% in parallel and perpendicular orientations, respectively. Conclusions: BaSO{sub 4} mixed with PBS is a good contrast agent in biodegradable polymer marker because of minimal artifacts in x-ray images and minimal dose reduction in proton therapy. The flexibility of the size is considered to be an advantage of this material over solid type fiducials.

60 APPLIED LIFE SCIENCES↗

Simulations of Small-Pore Microchannel Plates for Fast Gated X-ray Imaging and Spectroscopy of High-Energy Density Plasmas

This poster describes work done at National Security Technologies, LLC (NSTec), and Sandia National Laboratories (SNL) over the past several years on the design and characterization of microchannel plate (MCP)-based fast-gated x-ray imagers for use on the SNL Z machine. These cameras use 10-micron-pore MCPs similar to the type used for spectroscopy and imaging applications at other facilities. To aid in the understanding of MCP behavior, we have developed a Monte Carlo simulation model for prediction of MCP response. The code contains a detailed physical model of the electron cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Excellent agreement between the Monte Carlo simulations and laboratory measurements has been achieved. Here, we apply our simulation model to 2-micron-pore MCPs, which, while readily available from a variety of vendors, are not used in imaging applications. We investigated the DC and pulsed gain characteristics of such an MCP, with particular emphasis on dynamic range, temporal response, and spatial resolution. The results are compared to the predicted and measured characteristics of 10-micron-pore MCPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗