Search NASA⌕ Search

SEARCH · Search NASA

Results for “load shape”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Development and Characterization of Improved NiTiPd High-Temperature Shape-Memory Alloys by Solid-Solution Strengthening and Thermomechanical Processing

The need for compact, solid-state actuation systems for use in the aerospace, automotive, and other transportation industries is currently motivating research in high-temperature shape-memory alloys (HTSMA) with transformation temperatures greater than 100 C. One of the basic high-temperature alloys investigated to fill this need is Ni(19.5)Ti(50.5)Pd30. Initial testing has indicated that this alloy, while having acceptable work characteristics, suffers from significant permanent deformation (or ratcheting) during thermal cycling under load. In an effort to overcome this deficiency, various solid-solution alloying and thermomechanical processing schemes were investigated. Solid-solution strengthening was achieved by substituting 5at% gold or platinum for palladium in Ni(19.5)Ti(50.5)Pd30, the so-called baseline alloy, to strengthen the martensite and austenite phases against slip processes and improve thermomechanical behavior. Tensile properties, work behavior, and dimensional stability during repeated thermal cycling under load for the ternary and quaternary alloys were compared. The relative difference in yield strength between the martensite and austenite phases and the dimensional stability of the alloy were improved by the quaternary additions, while work output was only minimally impacted. The three alloys were also thermomechanically processed by cycling repeatedly through the transformation range under a constant stress. This so-called training process dramatically improved the dimensional stability in these samples and also recovered the slight decrease in work output caused by quaternary alloying. An added benefit of the solid-solution strengthening was maintenance of enhanced dimensional stability of the trained material to higher temperatures compared to the baseline alloy, providing a greater measure of over-temperature capability.

Bigelow, Glen↗

Expandable implant and implant system

An embodiment of the invention includes an expandable implant to endovascularly embolize an anatomical void or malformation, such as an aneurysm. An embodiment is comprised of a chain or linked sequence of expandable polymer foam elements. Another embodiment includes an elongated length of expandable polymer foam coupled to a backbone. Another embodiment includes a system for endovascular delivery of an expandable implant (e.g., shape memory polymer) to embolize an aneurysm. The system may include a microcatheter, a lumen-reducing collar coupled to the distal tip of the microcatheter, a flexible pushing element detachably coupled to an expandable implant, and a flexible tubular sheath inside of which the compressed implant and pushing element are pre-loaded. Other embodiments are described herein.

59 BASIC BIOLOGICAL SCIENCES↗

Expandable implant and implant system

An embodiment of the invention includes an expandable implant to endovascularly embolize an anatomical void or malformation, such as an aneurysm. An embodiment is comprised of a chain or linked sequence of expandable polymer foam elements. Another embodiment includes an elongated length of expandable polymer foam coupled to a backbone. Another embodiment includes a system for endovascular delivery of an expandable implant (e.g., shape memory polymer) to embolize an aneurysm. The system may include a microcatheter, a lumen-reducing collar coupled to the distal tip of the microcatheter, a flexible pushing element detachably coupled to an expandable implant, and a flexible tubular sheath inside of which the compressed implant and pushing element are pre-loaded. Other embodiments are described herein.

Wilson, Thomas S.↗

Expandable implant and implant system

An embodiment of the invention includes an expandable implant to endovascularly embolize an anatomical void or malformation, such as an aneurysm. An embodiment is comprised of a chain or linked sequence of expandable polymer foam elements. Another embodiment includes an elongated length of expandable polymer foam coupled to a backbone. Another embodiment includes a system for endovascular delivery of an expandable implant (e.g., shape memory polymer) to embolize an aneurysm. The system may include a microcatheter, a lumen-reducing collar coupled to the distal tip of the microcatheter, a flexible pushing element detachably coupled to an expandable implant, and a flexible tubular sheath inside of which the compressed implant and pushing element are pre-loaded. Other embodiments are described herein.

Wilson, Thomas S.↗

Experimental temperature distribution and heat load characteristics of rotating heat pipes

Experimental results show conclusively that the presence of a small quantity of a noncondensable gas (NCG) mixed with the working fluid has a considerable effect on the condensation process in a rotating heat pipe. The temperature distribution in the condenser shows the blanketing effect of the NCG and the ratio of the molecular weight of the working fluid to that of the NCG has a very definite effect on the shape of this distribution. Some of the effects are quite similar to the well-established data on stationary heat pipes.

Daniels, T. C.↗

Hot rolling of ZK60 magnesium sheet with isotropic tensile properties from tubing made by Shear Assisted Processing and Extrusion (ShAPE)

In order to evaluate the viability of ShAPE processed Mg alloys as a feedstock for fabricating lightweight sheet material, tubes consisting of ShAPE-extruded Mg alloy ZK60 were flattened into plates and hot rolled at 450 °C to reductions of 37%, 68%, and 93%. The mechanical properties and microstructure of the rolled material were characterized through tensile testing and electron backscattered diffraction (EBSD). ZK60 specimens rolled to 68% reduction had tensile properties similar to published properties of rolled ZK60 sheets fabricated using conventional processes, and exhibited negligible tensile anisotropy referenced to the rolling direction. Additional rolling from 68% to 93% reduced the ultimate tensile stress in the rolling direction from 341.74±5.96 MPa to 260.76±22.4MPa. The yield stress and elongation to failure of the material also decreased from 292.16±1.11 MPa to 256.93±18.4 MPa and 6.95±1.94% to 3.38±0.51%, respectively, but negligible little anisotropy was observed with respect to loading direction. EBSD mapping indicated that the as-extruded ZK60 had texture rotated away from the basal direction which developed into a strong basal texture over numerous hot rolling steps. This evolution in texture has been observed after rolling for hot-rolled ZK60 fabricated through conventional extrusion processes. The initial grain structure was found to have experienced noticeable twinning from flattening the tube into plate. After hot rolling, the grain structure became more equiaxed, but the average grain diameter did not change appreciably from 5.15 ± 3.39 µm in the ShAPE extruded material, to 5.27 ± 12.44 µm in the 93% hot rolled sheet. This response to hot rolling is similar to the response of ZK60 fabricated using other methods such as Equal Channel Angular Processing (ECAP). Therefore, this work demonstrates ShAPE has the potential as an alternative method to producing feedstock for Mg alloy sheets. Modifications to the experimental procedure which could lead to improvements in observed properties are briefly discussed.

36 MATERIALS SCIENCE↗

Mapping of Texture and Phase Fractions in Heterogeneous Stress States during Multiaxial Loading of Biomedical Superelastic NiTi

Thermoelastic deformation mechanisms in polycrystalline biomedical-grade superelastic NiTi are spatially mapped using in situ neutron diffraction during multiaxial loading and heating. The trigonal R-phase is formed from the cubic phase during cooling to room temperature and subsequently deforms in compression, tension, and torsion. The resulting R-phase variant microstructure from the variant reorientation and detwinning processes are equivalent for the corresponding strain in tension and compression, and the variant microstructure is reversible by isothermal loading. The R-phase variant microstructure is consistent between uniaxial and torsional loading when the principal stress directions of the stress state are considered (for the crystallographic directions observed here). The variant microstructure evolution is tracked and the similarity in general behavior between uniaxial and torsional loading, in spite of the implicit heterogeneous stress state associated with torsional loading, pointed to the ability of the reversible thermoelastic transformation in NiTi to accommodate stress and strain mismatch with deformation. This ability of the R-phase, despite its limited variants, to accommodate stress and strain and satisfy strain incompatibility in addition to the existing internal stresses has significance for reducing irrecoverable deformation mechanisms during loading and cycling through the phase transformation.

36 MATERIALS SCIENCE↗

Effects of Inorganic Antiseptic on the Properties of Zein-Based Active Films

Zein, one of corn processing byproducts, has excellent film-forming ability. However, zein does not have intrinsic antibacterial or antioxidant activity which limits its direct applicability as active food packaging material. In the present study, the rod-shaped micro-sized ZnO crystals were incorporated into zein films to construct zein-based active films as active packaging material with antibacterial property. The morphologies, structural analysis and sizes of ZnO crystals were analyzed by field emission scanning electron microscope and X-ray diffraction. Prepared zein films were evaluated for ZnO loading and distribution. Furthermore, antibacterial activities on Gram-negative bacteria and Gram-positive bacteria were tested by using the disc diffusion method. Lastly, the stability of zein-based active films under the different storage temperature and humidity was investigated. The results showed that zein based-active films had well mechanical properties, stability and antibacterial activities, which were related to the sizes of ZnO crystals in films.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microstructure evolution in TRIP-aided seamless steel tube during T-shape hydroforming process

Transformation-induced plasticity aided seamless steel tube comprising of ferrite, bainite, and metastable austenite was processed through forging, piercing, cold-drawing, and two-stage heat treatment. T-shape hydroforming is a classic forming method for experimental research and practical production. The current work studied austenite-to-martensite transformation and microcrack initiation and propagation of the tube during T-shape hydroforming using electron backscattering diffraction, scanning electron microscopy, and transmission electron microscopy. The strain distribution in the bcc-phase and fcc-phase was studied by evaluating changes in the average local misorientation. Compared to the compressive stress, metastable austenite with similar strain surrounding or inside the grains transformed easier under tensile loading conditions. The inclusions were responsible for microcrack initiation. The propagation of the cracks is hindered by martensite/austenite constituent due to transformation induced plasticity effect. The volume fraction of untransformed retained austenite decreased with increase in strain implying transformation-induced plasticity effect. - Highlights: • Hydroformed tubes processed via TRIP concept • EBSD provided estimate of micro local strain. • Retained austenite hinders propagation of microcracks.

36 MATERIALS SCIENCE↗

Physics of Multi-Planar and Compact Cylindrical Wire Arrays Implosions on University-Scale Z-pinch Generators

The presented research focuses on investigation of Z-pinch plasma formation, implosion, and radiation characteristics as a function of the load configuration. The single planar and multi-planar wire arrays as well as compact cylindrical wire arrays were studied on the 1.3 MA UNR Zebra and 1 MA Cornell COBRA generators. The largest yields and powers were found for W and Mo double planar and compact wire arrays. A possibility of radiation pulse shaping was demonstrated. Two types of bright spots were observed in plasmas. A comparison of Mo double planar and compact wire array data indicates the possibility that the same heating mechanism operates during the final implosion and stagnation stages.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pitfalls of tungsten multileaf collimator in proton beam therapy

Purpose: Particle beam therapy is associated with significant startup and operational cost. Multileaf collimator (MLC) provides an attractive option to improve the efficiency and reduce the treatment cost. A direct transfer of the MLC technology from external beam radiation therapy is intuitively straightforward to proton therapy. However, activation, neutron production, and the associated secondary cancer risk in proton beam should be an important consideration which is evaluated. Methods: Monte Carlo simulation with FLUKA particle transport code was applied in this study for a number of treatment models. The authors have performed a detailed study of the neutron generation, ambient dose equivalent [H*(10)], and activation of a typical tungsten MLC and compared with those obtained from a brass aperture used in a typical proton therapy system. Brass aperture and tungsten MLC were modeled by absorber blocks in this study, representing worst-case scenario of a fully closed collimator. Results: With a tungsten MLC, the secondary neutron dose to the patient is at least 1.5 times higher than that from a brass aperture. The H*(10) from a tungsten MLC at 10 cm downstream is about 22.3 mSv/Gy delivered to water phantom by noncollimated 200 MeV beam of 20 cm diameter compared to 14 mSv/Gy for the brass aperture. For a 30-fraction treatment course, the activity per unit volume in brass aperture reaches 5.3 x 10{sup 4} Bq cm{sup -3} at the end of the last treatment. The activity in brass decreases by a factor of 380 after 24 h, additional 6.2 times after 40 days of cooling, and is reduced to background level after 1 yr. Initial activity in tungsten after 30 days of treating 30 patients per day is about 3.4 times higher than in brass that decreases only by a factor of 2 after 40 days and accumulates to 1.2 x 10{sup 6} Bq cm{sup -3} after a full year of operation. The daily utilization of the MLC leads to buildup of activity with time. The overall activity continues to increase due to {sup 179}Ta with a half-life of 1.82 yr and thus require prolonged storage for activity cooling. The H*(10) near the patient side of the tungsten block is about 100 {mu}Sv/h and is 27 times higher at the upstream side of the block. This would lead to an accumulated dose for therapists in a year that may exceed occupational maximum permissible dose (50 mSv/yr). The value of H*(10) at the upstream surface of the tungsten block is about 220 times higher than that of the brass. Conclusions: MLC is an efficient way for beam shaping and overall cost reduction device in proton therapy. However, based on this study, tungsten seems to be not an optimal material for MLC in proton beam therapy. Usage of tungsten MLC in clinic may create unnecessary risks associated with the secondary neutrons and induced radioactivity for patients and staff depending on the patient load. A careful selection of material for manufacturing of an optimal MLC for proton therapy is thus desired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal control of a low wing-loading STOL aircraft

Linear optimal quadratic control theory is applied to a low wing-loading STOL aircraft for ride quality and flight path following. Design criteria include minimum rms response to wind turbulence and desired transient response characteristics. Design techniques include proper choosing of design versus evaluation models, choosing appropriate performance index responses, and use of classical evaluation techniques. Results are obtained through a combination of frequency response shaping and gust observation. Effects of control rate and authority saturation are examined with a new rapid calculation of random input describing functions. Parameter sensitivity is also evaluated using a Liapunov type matrix equation.

Cunningham, T. B.↗

Dynamic analysis of straight and involute tooth forms

The effect of load speed on straight and involute tooth forms is studied using several finite-element models. It is found that for rapidly rotating gears and sprockets, the load speed along the tooth surface can significantly affect the tooth vibration. Indeed, it is found that for sufficiently high load speeds and for sufficiently slender tooth forms, the tooth deflection can, at times, be directed opposite to the load direction. Comparisons are made of various dynamic models of gear and sprocket teeth. It is shown that for stubby tooth forms there is considerable difference between results obtained with finite element models and results obtained with Timoshenko beam models. Finally, it is shown that gear or sprocket vibrations can be induced by the shape of the tooth form itself. This effect becomes increasingly significant at higher speeds.

Lin, H. H.↗

Interplanetary magnetic field control of the Mars bow shock - Evidence for Venuslike interaction

The Mars bow shock location and shape have been determined by examining the Phobos spacecraft magnetometer data. Observations show that the position of the terminator bow shock varies with interplanetary magnetic field orientation in the same way as at Venus. The shock is farthest from Mars in the direction of the interplanetary electric field, consistent with the idea that mass loading plays an important role in the solar wind interaction with Mars. The shock cross section at the terminator plane is asymmetric and is controlled by the interplanetary magnetic field. The shock is farther from Mars during solar maximum. Thus the solar wind interaction with Mars appears to be Venuslike, with a magnetic moment too small to affect significantly the solar wind interaction.

Zhang, T. L.↗

Correlation of finite element free vibration predictions using random vibration test data

Finite element analysis is regularly used during the engineering cycle of mechanical systems to predict the response to static, thermal, and dynamic loads. The finite element model (FEM) used to represent the system is often correlated with physical test results to determine the validity of analytical results provided. Results from dynamic testing provide one means for performing this correlation. One of the most common methods of measuring accuracy is by classical modal testing, whereby vibratory mode shapes are compared to mode shapes provided by finite element analysis. The degree of correlation between the test and analytical mode shapes can be shown mathematically using the cross orthogonality check. A great deal of time and effort can be exhausted in generating the set of test acquired mode shapes needed for the cross orthogonality check. In most situations response data from vibration tests are digitally processed to generate the mode shapes from a combination of modal parameters, forcing functions, and recorded response data. An alternate method is proposed in which the same correlation of analytical and test acquired mode shapes can be achieved without conducting the modal survey. Instead a procedure is detailed in which a minimum of test information, specifically the acceleration response data from a random vibration test, is used to generate a set of equivalent local accelerations to be applied to the reduced analytical model at discrete points corresponding to the test measurement locations. The static solution of the analytical model then produces a set of deformations that once normalized can be used to represent the test acquired mode shapes in the cross orthogonality relation. The method proposed has been shown to provide accurate results for both a simple analytical model as well as a complex space flight structure.

Chambers, Jeffrey A.↗

Microstructure Anisotropy Effects on Fracture and Fatigue Mechanisms in Shape Memory Alloy Martensites

The chief scientific object was to investigate the fatigue and fracture mechanisms in NiTi shape memory alloys, in the presence of stress concentrating factors such as micro-pores and notches. In particular, the interactions between structure (factors related to the geometry of the specimen, such as holes, pores and notches) and microstructure (related to properties of the material such as grains, secondary phases, twins) in influencing the inelastic deformation, leading up to fracture in NiTi was examined. Primarily, there were two major thrusts. The first thrust focused on fracture behavior in Shape Memory Alloys where the high crystal symmetry cubic phase transformed into the low symmetry phase during deformation and propagation of cracks. This thrust revealed the interplay between size of micro-pores, size of grains and grain orientations in determining the resistance to crack growth, during cyclic tensile deformation of porous-like NiTi specimens. The role of secondary phases (impurities of Ti, often formed during fabrication) were also shown to induce local inelastic deformation gradients during tensile deformation and reduce overall extent of deformation. The second thrust focused on the fatigue and fracture behavior in the low crystal symmetry martensite phase. Unlike high symmetry phases, characterization of deformation in low symmetry phases such as martensitic NiTi has been challenging, due to a hierarchical microstructure spanning from nanoscale twins to the macroscale, a highly anisotropic microstructure stemming from the low crystal symmetry and a multitude of inelastic mechanisms for deformation. Thus, advanced X-ray techniques such as 3D high-energy diffraction microscopy and x-ray micro-Laue diffraction and spectroscopy were used in conjunction with traditional techniques such as SEM and TEM to understand the inelastic deformation in the martensite phase in NiTi, in the presence of notches. This thrust revealed a stark difference in deformation mechanisms based on the nature of stress: regions near the notch experience a highly triaxial stress while those far away experience a uniaxial stress. Additionally, while regions close to the notch were shown to deform locally by amorphization/nanocrystallization, ultimately leading to fracture, regions far away from the notch deformed in a more traditional manner, with detwinning and twin reorientation the primary mechanisms of deformation. More importantly, this thrust revealed that in the presence of structural factors such as notches, the traditional picture of reorientation (coalescence) of nanoscale martensite twins into increasingly larger domains with increased loading does not hold true, even up to fracture of the specimen. These conclusions will inform the modeling and understanding of deformation behavior of specimens, where structure and microstructure coexist and interact.

36 MATERIALS SCIENCE↗

Lithium-loaded liquid scintillator production for the PROSPECT experiment

This work reports here the production and characterization of lithium-loaded liquid scintillator (LiLS) for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT) . Fifty-nine 90 liter batches of LiLS ( 6 Li mass fraction 0.082%±0.001%) were produced and samples from all batches were characterized by measuring their optical absorbance relative to air, light yield relative to a pure liquid scintillator reference, and pulse shape discrimination capability. Fifty-seven batches passed the quality assurance criteria and were used for the PROSPECT experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atoms to fibers: Identifying novel processing methods in the synthesis of pitch-based carbon fibers

Understanding and optimizing the key mechanisms used in the synthesis of pitch-based carbon fibers (CFs) are challenging, because unlike polyacrylonitrile-based CFs, the feedstock for pitch-based CFs is chemically hetero- geneous, resulting in complex fabrication leading to inconsistency in the final properties. In this work, we use molecular dynamics simulations to explore the processing and chemical phase space through a framework of CF models to identify their effects on elastic performance. The results are in excellent agreement with experiments. We find that density, followed by alignment, and functionality of the molecular constituents dictate the CF mechanical properties more strongly than their size and shape. Last, we propose a previously unexplored fabrication route for high-modulus CFs. Unlike graphitization, this results in increased sp 3 fraction, achieved via generating high-density CFs. In addition, the high sp 3 fraction leads to the fabrication of CFs with isometric compressive and tensile moduli, enabling their potential applications for compressive loading.

01 COAL, LIGNITE, AND PEAT↗