Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Genomic Island Identification Software v 1.0

Genomic islands are key mobile DNA elements in bacterial evolution, that can distinguish pathogenic strains from each other, or distinguish pathogenic strains from non-pathogenic strains. Their detection in genomes is a challenging problem. We present 3 main software components that attack the island detection problem on two different bases: 1) the preference of islands to insert in chromosomal tRNA or tmRNA genes (islander.pl), and 2) islands' sporadic occurrence among closely related strains. The latter principle is employed in both an algorithm (learnedPhyloblocks.pl) and a visualization method (panGenome.pl). Component islander.pl finds islands based on their preference for a particular target gene type. We annotate each tRNA and tmRNA gene, find fragments of each such gene as candidates for the distal ends of islands, and filter candidates to remove false positives. Component learnedPhyloblocks.pl uses islands found by islander.pl and other methods as a training set to find new islands. Reference genomes are aligned using mugsy, then the "phylotypes" or patterns of occurrence in the reference set are determined for each position in the target genome, and those phylotypes most enriched in the training set of islands are followed to detect yet more islands. Component panGenome.pl produces a big-data visualization of the chromosomally-ordered "pan-genome", that includes every gene of every reference genome (x-axis, pan-genome order; y-axis, reference genomes; color-coding, gene presence/absence etc.), islands appearing as dark patches.

Source record↗

Measuring Broadband IR Irradiance in the Direct Solar Beam and Recent Developments

Solar and atmospheric science radiometers such as pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference which is maintained by Absolute Cavity Radiometers (ACRs). An ACR is an open cavity with no window, developed to measure the extended broadband spectrum of the terrestrial direct solar beam irradiance that extends beyond the ultraviolet and infrared bands; i.e. below 0.2 um and above 50 um, respectively. On the other hand, the pyranometers and pyrheliometers were developed to measure broadband shortwave irradiance from approximately 0.3 um to 3 um, while the present photovoltaic cells are limited to the spectral range of approximately 0.3 um to 1 um. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in the solar and atmospheric science literature. Pyrgeometers, which measure the atmospheric longwave irradiance, are also used for solar and atmospheric science applications and calibrated with traceability to a consensus reference, yet they are calibrated during nighttime only, because no consensus reference has been established for the daytime longwave irradiance. This poster describes a method to measure the broadband longwave irradiance in the terrestrial direct solar beam from 3 um to 50 um, as a first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The described method is used to measure the irradiance from sunrise to sunset; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 with an estimated uncertainty of 1.5 Wm-2, for a solar zenith angle range from 80 degrees to 16 degrees, respectively. Recent development shows that there is greater than 1.1 percent bias in measuring shortwave solar irradiance.

14 SOLAR ENERGY↗

Self-referenced continuous-variable quantum key distribution

Various technologies for continuous-variable quantum key distribution without transmitting a transmitter's local oscillator are described herein. A receiver on an optical transmission channel uses an oscillator signal generated by a light source at the receiver's location to perform interferometric detection on received signals. An optical reference pulse is sent by the transmitter on the transmission channel and the receiver computes a phase offset of the transmission based on quadrature measurements of the reference pulse. The receiver can then compensate for the phase offset between the transmitter's reference and the receiver's reference when measuring quadratures of received data pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systems and methods for switched-inductor integrated voltage regulators

Power controller includes an output terminal having an output voltage, at least one clock generator to generate a plurality of clock signals and a plurality of hardware phases. Each hardware phase is coupled to the at least one clock generator and the output terminal and includes a comparator. Each hardware phase is configured to receive a corresponding one of the plurality of clock signals and a reference voltage, combine the corresponding clock signal and the reference voltage to produce a reference input, generate a feedback voltage based on the output voltage, compare the reference input and the feedback voltage using the comparator and provide a comparator output to the output terminal, whereby the comparator output determines a duty cycle of the power controller. An integrated circuit including the power controller is also provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precision circuit calculations in hostile environments.

Sensing and calculating electronic systems with stringent accuracy requirements use internal standard voltages for references. Conceptually, this is related to using some unit measurement for counting any quantity. The high precision electronic components used in systems in the nation’s stockpile also make use of these standard voltages. The need for stable voltage references has been long-standing in the overall electronics industry. For many applications, the most pressing need is for stability of a reference voltage as the circuit temperature varies. Typical circuit components have temperature coefficients for their operational characteristics that are given in some delta per degree centigrade and these coefficients can be either positive or negative. Thus, it is natural to consider building a circuit out of components that have complementary temperature coefficients so that the operating characteristics of the circuit have a net zero temperature coefficient. This is the fundamental basis of precision voltage reference (PVR) circuit operation and it is straightforward to extend this type of stabilization to reduce shifts caused by hostile environment radiation.

42 ENGINEERING↗

Method and apparatus for determining a normal combustion characteristic for an internal combustion engine from an accelerometer signal

The method comprises operating a calibration engine, and collecting combustion characteristic data and reference accelerometer signals, which are correlated with each other and stored in a calibration table. The calibration table can be used by an engine to determine a real-time normal combustion characteristic when the engine is operating by collecting a real-time accelerometer sensor signal and cross correlating with the correlated data stored in the calibration table. Accordingly, the apparatus comprises a calibration engine comprising a calibration sensor, a reference accelerometer sensor and a data storage device for storing the collected calibration data that is correlated with the collected reference accelerometer signals, and an engine equipped with an accelerometer sensor, a calibration table and an electronic engine controller programmed to receive real-time accelerometer signals and cross correlate them with reference accelerometer signals to determine a real-time normal combustion characteristic.

Huang, Jian↗

Benzothiophene-based redox molecules for flow battery

The present invention provides a redox flow battery comprising a negative electrode (also referred to herein as an “anode”) immersed in a first liquid electrolyte (also referred to herein as a “negative electrolyte” or “anolyte”), a positive electrode (also referred to herein as a “cathode”) immersed in a second liquid electrolyte (also referred to herein as a “positive electrolyte” or “catholyte”), and a cation-permeable separator (e.g., a membrane or other cation-permeable material) partitioning the negative electrode/anolyte from the positive electrode/catholyte. The redox reactant of the catholyte comprises a compound of Formula (I) as described herein.

25 ENERGY STORAGE↗

Graph Generation with a Focusing Lexicon

Reference datasets are an essential part of developing effective data exploration tools. Many reference datasets are synthetic in nature, seeding real-world properties into generation routines. Others are laboriously curated from original source materials. This is a time-consuming process that requires significant domain expertise all along the process. This paper presents a third path: deriving a network from real-world source materials using automated tools. By properly grounding the tools in a small collection of curated documents, a larger corpus be automatically processed with greater confidence. The end system leverages human knowledge (in the initial document curation), but with much less time commitment enabled by automation. Our ultimate goal is to produce reference datasets, derived from real-world data that capture aspects salient to a specific activity in the context of all of the activities in the data-set. Our reference datasets take the form of graphs.

Chandra Shekar, Mayanka↗

Feed-forward spectral calibration methodology for line-scanned tunable laser absorption spectroscopy

A generalized feed-forward method for accurate tunable laser absorption spectroscopy includes generating a laser beam. The generated laser beam is directed down a reference path and a test/sample path. One or more parameters are extracted from the reference path. The one or more parameters, extracted from the reference path, are used as feed-forward, to adjust spectral analysis of the test/sample path to detect a composition and/or concentration of an analyte gas within the test/sample path. The extraction of the one or more parameters from the reference path and the spectral analysis of the test/sample path are performed substantially concurrently.

Green, William↗

Tampering detection and location identification of digital audio recordings

Systems and methods for detecting a tampering and identifying a location of a digital recording are provided. A frequency sequence and a phase angle sequence may be extracted from the digital recording. A portion of the frequency sequence may be matched to one of a plurality of reference frequency sequences, and a portion of the phase angle sequence may be matched to one of a plurality of reference phase angle sequences. Tampering of the digital recording may be detected when the frequency and phase sequences differ from the matched reference sequences. Moreover, a noise sequence may be extracted from the extracted frequency sequence. A location of the digital recording may be identified by matching the noise sequence to one of a plurality of noise sequences of the plurality of reference frequency sequences.

Chai, Jidong↗

Controlled Pyroshock Transients Can Be Used To Better Match Operational Shock Transients and Improve Shock Analysis and Testing

SRS analysis and testing to SRS is known to be conservative since SRS is generated from maxi-max shock transient data, maximum peaks are assumed to occur for each mode simultaneously, and the structural dynamics are not accounted for between the shock source and the test article. Knowing the structural dynamics of a shock test setup it is possible to subscribe a force shock transient applied at a particular strike location and direction to achieve a desired shock transient at a test reference accelerometer. The SRS at this test accelerometer reference location can be used to compare to the reference SRS, but the key reference is the shock transient not the SRS, which should lead to more realistic shock testing that better matches operational shock transient data and reduces artificial test failures that don’t occur in operational usage. The desired test shock transient should match operational shock transients. As such, the test shock transient should look similar to the operational shock transient and have similar positive and negative peaks, the same shape, and the same duration. Many shock transients can be created that satisfy an SRS, but better control of these shock transient parameters is needed to better match operational shock transients so that more realistic and less conservative shock testing can be performed. Three different shock transients are presented that satisfy a given SRS and the results are compared for an electronic board (test article) attached to a circular shock resonance test plate.

SRS, shock transient, frequency domain, FRF↗

Organic redox molecules for flow batteries

The present invention provides a redox flow battery comprising a negative electrode (also referred to herein as an “anode”) immersed in a first liquid electrolyte (also referred to herein as a “negative electrolyte” or “anolyte”), a positive electrode (also referred to herein as a “cathode”) immersed in a second liquid electrolyte (also referred to herein as a “positive electrolyte” or “catholyte”), and a cation-permeable separator (e.g., a membrane or other cation-permeable material) partitioning the negative electrode/anolyte from the positive electrode/catholyte. The redox reactant of the catholyte comprises a compound of Formula (I) as described herein.

25 ENERGY STORAGE↗

Evaluation of irradiation effects on concrete structure

In assessing the soundness of irradiated concrete of nuclear power plants operated for more than 30 years, reference levels are employed: 1x10{sup 20} n/cm{sup 2} for fast neutrons and 2x10{sup 10} rad (2x10{sup 5} kGy) for gamma rays. Concrete structures are regarded as sound when the estimated irradiance levels after 60 years of operation are less than the reference levels. The reference levels were obtained from a paper by Hilsdorf. It was found, however, that the test conditions in which data were obtained by the researchers referred in that paper are very different from the irradiation and heat conditions usually found in a Light Water Reactor (LWR), and therefore aren't appropriate for assessing the soundness of irradiated concrete of an LWR. This paper investigates the interactions between radiation and concrete and presents the results of gamma ray irradiation tests on cement paste samples in order to provide a better understanding of the irradiation effects on concrete. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Increasing ROI Using Your Digital Twin for Model Based Engineering

The purpose of this work is to identify innovative ways of using the plant reference simulator or digital twin differently than it has traditionally been used in the past. This paper will identify reasons that the plant reference simulator will support varying levels of model based design and engineering. I will point out real world examples in which the plant reference simulator was used to identify problems with engineering designs, digital control systems and plant modifications. The earlier these issues can be identified and resolved, the less impact they have on the plant modification or upgrade. By using the plant reference simulator earlier in the engineering process, utilities and engineering organizations can minimize costly outage extensions and increase the return on the investment made in the simulator.

42 ENGINEERING↗

AWE neutron spectrometry results from Godiva-IV (NCERC) characterization - Paper 135

In recent years, it was deemed necessary for the Godiva-IV critical assembly - along with other assemblies collectively forming what is now known as the National Critical Experiments Research Center (NCERC) - to relocate to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). An experiment was proposed (IER-148) under the Nuclear Criticality Safety Program for an international inter-comparison of Nuclear Accident Dosimetry (NAD) using the Godiva-IV assembly, in order to arrest the long term decline in the testing and validation of these systems. Due to the knock-on effect of the change of location on the neutron leakage spectrum, however, new reference points must be established. As a precursor to the intercomparison an additional experiment (IER-147) was proposed with the aim of measuring these reference values for the current Godiva-IV radiation field in the DAF. To establish the reference values Godiva was run in both a sub-critical steady-state mode and a super prompt-critical, pulsed mode. AWE provided neutron spectrometry capabilities in the form of a ROSPEC and Bonner sphere Spectrometer (BSS) for the steady-state experiment, and a Passive Bonner sphere Spectrometer (PBSS) for the pulsed experiment. Neutron leakage spectrum measurements carried out by AWE have been used to determine reference doses around Godiva which can be used for future NAD inter-comparisons. A good comparison of steady-state and pulsed spectra indicates a strong likelihood of being able to relate the power level of both operational methods of the reactor for future work in other fields. Further work is required to determine the fidelity of the thermal peak and it is the intention of AWE to bring additional thermal information to the unfolding process through the incorporation of supplementary activation foils used in the irradiations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Solar-battery integrated DC system

A DC bus is connected to a PV array, a battery or both, to power a grid connected inverter load on the bus. A system and method is described for controlling current flow on a DC bus regardless of the type of inverter. A converter receives a DC battery voltage. A switching module controls current flow through the converter. A current generator generates a reference current in response to a reference voltage. A comparator connected at the output of the current generator compares the reference current with a battery current and outputs a signal to a controller. The controller generates a reference value. A PWM generator modulates the switch module to control current flow and energy flow between the DC bus and the battery. The current from the DC bus to the inverter is controlled to allow proper grid-connected operation regardless of inverter type.

Atcitty, Stanley↗

(Doublon) Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed, such as the Transient Heatsink Overpower Response capsule (THOR), the Transient Water Irradiation System for TREAT (TWIST), and Sirius. Each has provided valuable data for materials performance and reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments can cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used for code verification, validation and uncertainty quantification. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the verification, validation and uncertainty quantification approach. To overcome this problem, the autocorrected reactimeter algorithm (ACRA) has been developed. This approach infers a time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e., when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for developing an improved version of the ACRA that does not require frozen configurations. To develop this new algorithm, we need a precise and unbiased implementation of the inverse point kinetic equations (IPKEs) as any error in the reactivity evaluation will be propagated into the choice of the optimal spatial correction. Indeed, the previous reactimeter algorithm would use approximations, such as a negligible flux amplitude derivative, to focus on rapidity. For the numerical validation of ACRA, we aim at absolute error under for reactivity derived from signals similar to the one of this study. In this summary, we test eight different IPKE implementations. Each will process a mockup signal built for this study, similar to those that the future ACRA will process. Each reactivity output will be compared to the reference reactivity that has been used to generate the mockup signal. The implementation minimizing the difference with the reference reactivity will be used in the development of a new ACRA formulation.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IAEA Coordinated Research Project on Master Curve Approach to Monitor Fracture Toughness of RPV Steels: Final Results of the Experimental Exercise to Support Constraint Effects

The precracked Charpy single-edge notched bend, SE(B), specimen (PCC) is the most likely specimen type to be used for determination of the reference temperature, T0, with reactor pressure vessel (RPV) surveillance specimens. Unfortunately, for many RPV steels, significant differences have been observed between the T0 temperature for the PCC specimen and that obtained from the 25-mm thick compact specimen [1TC(T)], generally considered the standard reference specimen for T0. This difference in T0 has often been designated a specimen bias effect, and the primary focus for explaining this effect is loss of constraint in the PCC specimen. The International Atomic Energy Agency (IAEA) has developed a coordinated research project (CRP) to evaluate various issues associated with the fracture toughness Master Curve for application to light-water RPVs. Topic Area 1 of the CRP is focused on the issue of test specimen geometry effects, with emphasis on determination of T0 with the PCC specimen and the bias effect. Topic Area 1 has an experimental part and an analytical part. Participating organizations for the experimental part of the CRP performed fracture toughness testing of various steels, including the reference steel JRQ (A533-B-1) often used for IAEA studies, with various types of specimens under various conditions. Additionally, many of the participants took part in a round robin exercise on finite element modeling of the PCVN specimen, discussed in a separate paper. Results from fracture toughness tests are compared with regard to effects of specimen size and type on the reference temperature T0. It is apparent from the results presented that the bias observed between the PCC specimen and larger specimens for Plate JRQ is not nearly as large as that obtained for Plate 13B (-11 C vs -37 C) and for some of the results in the literature (bias values as much as -45 C). This observation is consistent with observations in the literature that show significant variations in the bias that are dependent on the specific materials being tested. There are various methods for constraint adjustments and two methods were used that reduced the bias for Plate 13B from -37 C to -13 C in one case and to -11 C in the second case. Unfortunately, there is not a consensus methodology available that accounts for the differences observed with different materials. Increasing the Mlim value in the ASTM E-1921 to ensure no loss of constraint for the PCC specimen is not a practicable solution because the PCC specimen is derived from CVN specimens in RPV surveillance capsules and larger specimens are normally not available. Resolution of these differences are needed for application of the master curve procedure to operating RPVs, but the research needed for such resolution is beyond the scope of this CRP.

36 MATERIALS SCIENCE↗