Search NASA⌕ Search

SEARCH · Search NASA

Results for “separability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

The Chemistry of Separations Ligand Degradation by Organic Radical Cations

Solvent based extractions of used nuclear fuel use designer ligands in an organic phase extracting ligand complexed metal ions from an acidic aqueous phase. These extractions will be performed in highly radioactive environments, and the radiation chemistry of all these complexants and their diluents will play a major role in determining extraction efficiency, separation factors, and solvent-recycle longevity. Although there has been considerable effort in investigating ligand damage occurring in acidic water radiolysis conditions, only minimal fundamental kinetic and mechanistic data has been reported for the degradation of extraction ligands in the organic phase. Extraction solvent phases typically use normal alkanes such as dodecane, TPH, and kerosene as diluents. The radiolysis of such diluents produce a mixture of radical cations (R •+ ), carbon-centered radicals (R • ), solvated electrons, and molecular products such as hydrogen. Typically, the radical species will preferentially react with the dissolved oxygen present to produce relatively inert peroxyl radicals. This isolates the alkane radical cation species, R •+ as the major radiolytically-induced organic species that can react with, and degrade, extraction agents in this phase. Here we report on our recent studies of organic radical cation reactions with various ligands. Elucidating these parameters, and combining them with the known acidic aqueous phase chemistry, will allow a full, fundamental, understanding of the impact of radiation on solvent extraction based separation processes to be achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of recrystallization on phase separation kinetics of oxide dispersion strengthened Fe Cr Al alloy

The effect of different starting microstructures on the kinetics of Fe-rich ({alpha}) and Cr-rich ({alpha}') phase separation during aging of Fe-Cr-Al oxide dispersion strengthened (ODS) alloys has been analyzed with a combination of atom probe tomography and thermoelectric power measurements. The results revealed that the high recrystallization temperature necessary to produce a coarse grained microstructure in Fe-base ODS alloys affects the randomness of Cr-atom distributions and defect density, which consequently affect the phase separation kinetics at low annealing temperatures.

36 MATERIALS SCIENCE↗

Superbase-derived protic ionic liquid extractants for metal ion separation

Solvent extraction of La 3+ and Ba 2+ by an ionic liquid extractant in an imidazolium-based ionic liquid diluent was investigated. Seven protic ionic liquid extractants were examined and these protic ILs are based on five organic superbases and either 6,6,7,7,8,8,8-heptafluoro-2,2-dimethyl-3,5-octadione (Hfod) or 1,1,1,5,5,5-hexafluoroacetylacetone (Hhfac) -diketones as anion. For fod-based extractants, the extraction efficiencies and separation factors were found to be concentration dependent. The effects of aqueous phase acidity, extractant structure, and extractant concentration on separation properties of La 3+ and Ba 2+ are discussed in this paper.

36 MATERIALS SCIENCE↗

Extraction and separation of iridium(Ⅳ) and rhodium(Ⅲ) from hydrochloric acid media by a quaternary ammonium-based hydrophobic eutectic solvent

We report the extraction and separation of iridium(IV) and rhodium(III) from hydrochloric acid solutions by a hydrophobic eutectic solvent composed of tetraheptylammonium chloride and decanoic acid have been studied for the first time. This eutectic solvent selectively extracts iridium(IV) over rhodium(III), the highest separation factor obtained is approximately 20. The effects of the main experimental factors (shaking time, the volume ratio of aqueous to organic phase, hydrochloric acid concentration, and the initial metal concentration in the aqueous phase) on the extraction behavior of iridium(IV) and rhodium(III) have been investigated. Ultraviolet–visible (UV–Vis) spectroscopy was applied to reveal the [IrCl 6 ] 2- complex to be a predominant species attributed to iridium(IV) extraction. To understand the underlying extraction mechanism, the initial iridium(IV) concentration in the aqueous phase has been varied and a corresponding mathematical model has been developed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An automated micro-separation system for the chromatographic removal of uranium matrix for trace element analysis by ICP-OES

An automated, miniaturized, off-line separation technique is presented here using an Elemental Scientific Inc. microFAST MC system with UTEVA resin to extract the uranium matrix from its trace element impurities in aqueous media. The collected fractions were analyzed for ~30 trace elements using inductively coupled plasma – optical emission spectroscopy. Ten replicate samples were processed with a single column resulting in precision ranging from 3.3% to 6.2% relative standard deviation with regards to the trace element recoveries. Accuracy, with respect to trace element concentrations in the U 3 O 8 Certified Reference Material 124-1, resulted in an average of 13.9% relative deviation while accuracy to the Canadian U3O8 reference material, CUP-2, resulted in an average relative deviation of 8.6%. In conclusion, the total separation time of this automated process was reduced to ~30 min per sample while employing a 0.5 mL UTEVA chromatographic resin bed and 2.5 mg of uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Resolution Separations and Improved Ion Production and Transmission in Metabolomics

The goal of metabolomics experiments is the detection and quantitation of as many sample components as reasonably possible in order to identify “features” that can be used to characterize the samples under study. When utilizing electrospray ionization to produce ions for analysis by mass spectrometry (MS), it is imperative that metabolome sample constituents be efficiently separated prior to ion production, in order to minimize the phenomenon of ionization suppression. Similarly, optimization of the MS inlet can lead to increased measurement sensitivity. This review will focus on the role of high resolution liquid chromatography (LC) separations in conjunction with improved ion production and transmission for LC-MS-based metabolomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sociological survey in a municipality with a high level separate collection programme in an area of historic unpopularity

Highlights: • Behaviours, opinions and knowledge of citizens on MSW management were investigated. • The knowledge level was better than that of nearby university students and citizens. • The higher the education level, the greater the level of knowledge was. • The local authority showed a leading role in terms of waste management. • Trust is the key to any social program success including waste management programs. - Abstract: Behaviours, opinions and knowledge of citizens on MSW and separate collection were investigated in the city of Mercato San Severino (about 22,000 people), in the Campania region of Southern Italy that is an area suffering from a serious solid waste emergency that has lasted over 17 years due to the absence of treatment facilities. The image of heaps of rubbish in the streets of Naples and other nearby cities is only one side of the coin. Mercato San Severino has adopted an effective kerbside collection system since 2001 and a pay-as-you-throw program during 2005, guaranteeing more than the minimum level of recycling required by the Italian legislation. Structured questionnaires were administered to a sample of 500 people in 2010. Chi-square tests of independence were applied to state whether the differences were statistically significant (5%). About 90% of the sample stated that the success of the separate collection program was due to either the citizens and local authority or only the local authority, highlighting the leading role of the local authority and confirming that trust is the key to any social program success. The registered level of knowledge was better than that of nearby university students and citizens. The higher the education level, the greater the level of knowledge was.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IgY14 and SuperMix immunoaffinity separations coupled with liquid chromatography-mass spectrometry for human plasma proteomic biomarker discovery

Interest in the application of advanced proteomics technologies to human blood plasma- or serum-based clinical samples for the purpose of discovering disease biomarkers continues to grow; however, the enormous dynamic range of protein concentrations in these types of samples (often >10 orders of magnitude) represents a significant analytical challenge, particularly for detecting low-abundance candidate biomarkers. In response, immunoaffinity separation methods for depleting multiple high- and moderate-abundance proteins have become key tools for enriching low-abundance proteins and enhancing detection of these proteins in plasma proteomics. Herein, we describe IgY14 and tandem IgY14-Supermix separation methods for removing 14 high-abundance and up to 60 moderate-abundance proteins, respectively, from human blood plasma and highlight their utility when combined with liquid chromatography-tandem mass spectrometry for interrogating the human plasma proteome.

59 BASIC BIOLOGICAL SCIENCES↗

Numerical simulation of flow regions in red mud separation thickener's feedwell by analysis of residence-time distribution

The residence-time distribution (RTD) and the compartment model were applied to characterizing the flow regions in red mud separation thickener’s feedwells. Combined with the experimental work, validated mathematical model as well as three-dimensional computational fluid dynamics (CFD) model was established to analyze the flow regions of feedwells on an industrial scale. The concept of RTD, although a well-known method for the characterization of mixing behavior in conventional mixers and reactors, is still a novel measure for the characterization of mixing in feedwells. Numerical simulation results show that the inlet feed rate and the aspect ratio of feedwells are the most critical parameters which affect the RTD of feedwell. Further simulation experiments were then carried out. Under the optimal operation conditions, the volume fraction of dead zone can reduce by10.8% and an increasement of mixing flow volume fraction by 6.5% is also observed. There is an optimum feed inlet rate depending on the feedwell design. The CFD model in conjunction with the RTD analysis then can be used as an effective tool in the design, evaluation and optimization of thickener feedwell in the red mud separation.

42 ENGINEERING↗

Dynamical separation of spherical bodies in supersonic flow

An experimental and computational investigation of the unsteady separation behaviour of two spheres in a highly supersonic flow is carried out. The spherical bodies, initially touching, are released with negligible relative velocity, an arrangement representing the idealized binary fragmentation of a meteoritic body in the atmosphere. In experiments performed in a Mach-4 Ludwieg tube, nylon spheres are initially suspended in the test section by weak threads and, following detachment of the threads by the arrival of the flow, fly freely according to the aerodynamic forces experienced. The resulting sphere motions and unsteady flow structures are recorded using high-speed shadowgraphy. The qualitative separation behaviour and the final lateral velocity of the smaller sphere are found to vary strongly with both the radius ratio and the initial alignment angle of the two spheres. More disparate radii and initial configurations in which the smaller sphere centre lies downstream of that of the larger sphere both increase the tendency for the smaller sphere to be entrained within the flow region bounded by the bow-shock of the larger body, rather than expelled from this region. At a critical angle for a given radius ratio (or a critical radius ratio for a given angle), transition from entrainment to expulsion occurs; at this critical value, the final lateral velocity is close to maximum due to the surfing effect noted by Laurence & Deiterding (J. Fluid Mech., vol. 676, 2011, pp. 396-431) at hypersonic Mach numbers. A high-precision tracking algorithm is used to provide quantitative comparisons between experiments and high-resolution inviscid numerical simulations, with generally favourable agreement.

Laurence, Stuart J↗

Scalable slot-die coating of phyllosilicate membranes for selective ion separations

Abstract Two-dimensional (2D) materials have recently drawn attention as candidate materials for molecular-scale membrane separations due to their tunable nanoscale interlayer properties. Phyllosilicates, a broad class of naturally abundant 2D clay minerals, offer significant advantages over synthetic 2D materials, including low cost, stability, and environmental compatibility. While these properties make phyllosilicates attractive for industrial-scale nanofiltration applications, phyllosilicate-based membranes have, to date, only been fabricated at the lab scale via vacuum filtration. Scalable fabrication methods are essential to advance the technical maturity of phyllosilicate membranes and bring these promising materials closer to large-scale adoption. Herein, we have successfully scaled up phyllosilicate (vermiculite) membrane fabrication via slot-die coating and roll-to-roll coating of an ethylenediamine–vermiculite (EDAVM) mixture onto nylon. The coated membranes are 1–2 μm $ \unicode{x03BC} \mathrm{m} $ mu m in thickness and exhibit similar structure and performance to vacuum-filtered EDAVM membranes. The membranes also show selectivity for monovalent ions over multivalent ions in binary salt mixtures. This work represents a major step toward scaling up phyllosilicate membranes for industrial ion separation applications such as resource recovery from water.

Booth, Austin [Princeton University]↗

Separation of Variant Methylated Histone Tails by Differential Ion Mobility

Differential ion mobility spectrometry (FAIMS) is emerging as a broadly useful tool for separation of isomeric modified peptides with post-translational modifications (PTMs) attached to alternative residues. Such separations were anticipated to become more challenging for smaller PTMs and longer peptides. Here we show that FAIMS can fully resolve localization variants involving a PTM as minuscule as methylation, even for larger peptides in the middle-down range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Separation of Unknown Organic–Metal Complexes by Liquid Chromatography–Inductively Coupled Plasma-Mass Spectrometry

Dissolved organic matter (DOM) is widely recognized to control the solubility and reactivity of trace metals in the environment. However, the mechanisms that govern metal-DOM complexation remain elusive, primarily due to the analytical challenge of fractionating and quantifying metal–organic species within the complex mixture of organic compounds that comprise DOM. Here, we describe a quantitative method for fractionation and element-specific detection of organic–metal complexes using liquid chromatography with online inductively coupled plasma mass spectrometry (LC–ICP-MS). The method implements a post-column compensation gradient to stabilize ICP–MS elemental response across the LC solvent gradient, thereby overcoming a major barrier to achieving quantitative accuracy with LC–ICP-MS. With external calibration and internal standard correction, the method yields concentrations of organic–metal complexes that were consistently within 6% of their true values, regardless of the complex’s elution time. We used the method to evaluate the effects of four stationary phases (C18, phenyl, amide, and pentafluoroylphenyl propyl) on the recovery and separation of environmentally relevant trace metals (Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in Suwannee River Fulvic Acid and Suwannee River Natural Organic Matter. The C18, amide, and phenyl phases generally yielded optimal metal recoveries (>75% for all metals except Pb), with the phenyl phase separating polar species to a greater extent than C18 or amide. We also fractionated organic-bound Fe, Cu, and Ni in oxidized and reduced soils, revealing divergent metal-DOM speciation across soil redox environments. Finally, by enabling quantitative fractionation of DOM-bound metals, our method offers a means for advancing a mechanistic understanding of metal–organic complexation throughout the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-High Resolution Ion Mobility Separations Utilizing Traveling Waves in a 13 m Serpentine Path Length Structures for Lossless Ion Manipulations Module

We report the development and initial evaluation of a 13-m path length Structures for Lossless Manipulations (SLIM) module for achieving high resolution separations using traveling waves (TW) with ion mobility (IM) spectrometry. The TW SLIM module was fabricated using two mirror-image printed circuit boards with appropriately configured RF, DC and TW electrodes and positioned with a 2.75-mm inter-surface gap. Ions were effective confined between the surfaces by RF-generated pseudopotential fields and moved losslessly through a serpentine path including 44 “U” turns using TWs. The ion mobility resolution was characterized at different pressures, gaps between the SLIM surfaces, TW and RF parameters. After initial optimization the SLIM IM-MS module provided about 5-fold higher resolution separations than present commercially available drift tube or traveling wave IM-MS platforms. Peak capacity and peak generation rates achieved were 246 and 370 s-1, respectively, at a TW speed of 148 m/s. The high resolution achieved in the TW SLIM IM-MS enabled e.g., isomeric sugars (Lacto-N-fucopentaose I and Lacto-N-fucopentaose II) to be baseline resolved, and peptides from a albumin tryptic digest much better resolved than with existing commercial IM-MS platforms. The present work also provides a foundation for the development of much higher resolution SLIM devices based upon both considerably longer path lengths and multi-pass designs.

Environmental Molecular Sciences Laboratory↗

Retention in porous layer pillar array planar separation platforms

Here, this work presents the retention capabilities and surface area enhancement of highly ordered, high-aspect-ratio, open-platform, two-dimensional (2D) pillar arrays when coated with a thin layer of porous silicon oxide (PSO). Photolithographically prepared pillar arrays were coated with 50–250 nm of PSO via plasma-enhanced chemical vapor deposition and then functionalized with either octadecyltrichlorosilane or n-butyldimethylchlorosilane. Theoretical calculations indicate that a 50 nm layer of PSO increases the surface area of a pillar nearly 120-fold. Retention capabilities were tested by observing capillary-action-driven development under various conditions, as well as by running one-dimensional separations on varying thicknesses of PSO. Increasing the thickness of PSO on an array clearly resulted in greater retention of the analyte(s) in question in both experiments. In culmination, a two-dimensional separation of fluorescently derivatized amines was performed to further demonstrate the capabilities of these fabricated platforms.

36 MATERIALS SCIENCE↗

Squeezing of Ion Populations and Peaks in Traveling Wave Ion Mobility Separations and Structures for Lossless Ion Manipulations using Compression Ratio Ion Mobility Programming

In this work, we report an approach for spatial and temporal gas phase ion population manipulation, and demonstrate its application for the collapse of the ion distributions in ion mobility (IM) separations into tighter packets providing higher sensitivity measurements in conjunction with mass spectrometry (MS). We do this for ions moving from a conventionally traveling wave (TW)-driven region to a region where the TW is intermittently halted or ‘stuttered’. This approach causes the ion packets spanning a number of TW-created traveling traps (TT) to be redistributed into fewer TT, resulting in spatial compression. The degree of spatial compression is controllable and determined by the ratio of stationary time of the TW in the second region to its moving time. This compression ratio ion mobility programming (CRIMP) approach has been implemented using Structures for Lossless Ion Manipulations (SLIM) in conjunction with MS. CRIMP with the SLIM-MS platform is shown to provide increased peak intensities, reduced peak widths, and improved S/N ratios with MS detection. CRIMP also provides a foundation for extremely long path length and multi-pass IM separations in SLIM providing greatly enhanced IM resolution by reducing the detrimental effects of diffusional peak broadening due to increasing peak widths.

Environmental Molecular Sciences Laboratory↗

Separation of Protactinium Employing Sulfur-Based Extraction Chromatographic Resins

Protactinium-230 (t 1/2 = 17.4 d) is the parent isotope of 230 U (t 1/2 = 20.8 d), a radionuclide of interest for targeted alpha therapy (TAT). Column chromatographic methods have been developed to separate no-carrier-added 230 Pa from proton irradiated thorium targets and accompanying fission products. Results reported within this paper demonstrate the use of novel sulfur bearing chromatographic extraction resins for the selective separation of protactinium. The recovery yield of 230 Pa was 93 ± 4% employing a R 3 P=S type commercially available resin and 88 ± 4% employing a DGTA (diglycothioamide) containing custom synthesized extraction chromatographic resin. The radiochemical purity of the recovered 230 Pa was measured via high purity germanium γ-ray spectroscopy to be >99.5% with the remaining radioactive contaminant being 95 Nb due to its similar chemistry to protactinium. Finally, measured equilibrium distribution coefficients for protactinium, thorium, uranium, niobium, radium, and actinium on both the R 3 P=S type and the DGTA resin in hydrochloric acid media are reported, to the best of our knowledge, for the first time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pillar[5]arene Based Conjugated Microporous Polymers for Propane/Methane Separation through Host–Guest Complexation

We present an efficient strategy for the preparation of conjugated microporous polymers incorporating pillar[5]arenes (P5-CMPs) with surface areas up to 400 m 2 g –1 via Pd-catalyzed Sonogashira–Hagihara cross-coupling reaction of triflate functionalized pillar[5]arene with 1,4-diethynylbenzene and 4,4'-diethynyl-1,1'-biphenyl linkers. In an effort to transfer intrinsic properties of pillar[5]arene, that is its ability to form strong host–guest complexes with linear hydrocarbons in solution, into the solid-state, we investigated the affinity of P5-CMPs toward propane gas. Unlike previously reported porous solids, which showed isosteric heats of adsorption ($Q$ st ) for propane in the range of 32.9–36.9 kJ mol–1 at zero coverage and increasing $Q$ st with rising loading due to intermolecular interactions between propane molecules, we observed very high $Q$ st values up to 53 kJ mol –1 at zero coverage, which gradually decreased to ~35 kJ mol –1 with increasing loadings. This observation indicates strong supramolecular host–guest complexation between propane and pillar[5]arene via multiple C–H/$π$ interactions, i.e., “macrocyclic effect” arising from the ideal size match of kinetic diameter of propane to the cavity of pillar[5]arene. This approach also allowed us to introduce thermodynamic selectivity for the separation of saturated hydrocarbons with low polarizability. High affinity of P5-CMPs for propane facilitated its efficient breakthrough separation from a simulated natural gas mixture (methane:propane, 9:1) at 298 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗