Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Unsteady Pressure-Sensitive Paint (UPSP) Shot Noise Reduction

In the study of unsteady Pressure-Sensitive Paint (uPSP) image data sets, pixel intensity values collected by Phantom cameras from multiple perspectives are used to calculate the surface pressure of an experimental model. This paper focuses on mitigation of shot noise which is introduced into the image data set by the cameras. Shot noise impacts the quality of data collected, increasing the system error in its pressure value calculations. This paper characterises statistical methods to reduce shot noise within experimental data by taking an average or weighted average across an area of pixels of their respective counts. Each combined-pixel has a higher total effective intensity value and therefore exhibits reduced noise throughout its time history. This is demonstrated by calculating the standard deviations of the combined pixel values through time, which decrease as the combined pixel area increases. Finally, these methods are compared across experimental wind tunnel conditions to examine their effectiveness at different Mach numbers. Ultimately, the results are used to recommend a blur filter type and size which will be applied to the raw image data prior to processing, as well as a minimum camera resolution for future experiments. Downstream of the filter application, the software to convert the 2D image data sets into surface pressure readings on a 3D grid use a ratio of decimation that assigns multiple pixels to each 3D grid node. This decimation ratio will also be aligned with the size of the blur filter, resulting in a more manageable data set size and compromised spatial resolution. Combined with the effect of the blur filter, the resulting pixel intensity readings will exhibit significantly reduced shot noise, reducing the magnitude of uncertainty and error in the final calculated pressure. For future tests, the camera spatial resolution must be sufficient to capture small flow and model features even after the recommended blur filter is applied. The image data set is taken from a uPSP experiment of the Space Launch System Block 1 cargo vehicle model in September 2019.

Lucy Tang↗

Electronic structure at coarse-grained resolutions from supervised machine learning

Computational studies aimed at understanding conformationally dependent electronic structure in soft materials require a combination of classical and quantum-mechanical simulations, for which the sampling of conformational space can be particularly demanding. Coarse-grained (CG) models provide a means of accessing relevant time scales, but CG configurations must be back-mapped into atomistic representations to perform quantum-chemical calculations, which is computationally intensive and inconsistent with the spatial resolution of the CG models. A machine learning approach, denoted as artificial neural network electronic coarse graining (ANN-ECG), is presented here in which the conformationally dependent electronic structure of a molecule is mapped directly to CG pseudo-atom configurations. By averaging over decimated degrees of freedom, ANN-ECG accelerates simulations by eliminating backmapping and repeated quantum-chemical calculations. The approach is accurate, consistent with the CG spatial resolution, and can be used to identify computationally optimal CG resolutions.

36 MATERIALS SCIENCE↗

PROBING LOCAL DENSITY INHOMOGENEITIES IN THE CIRCUMSTELLAR DISK OF A Be STAR USING THE NEW SPECTRO-ASTROMETRY MODE AT THE KECK INTERFEROMETER

We report on the successful science verification phase of a new observing mode at the Keck Interferometer, which provides a line-spread function width and sampling of 150 km s{sup -1} at the K'-band, at a current limiting magnitude of K' {approx} 7 mag with a spatial resolution of {lambda} / 2 B {approx} 2.7 mas and a measured differential phase stability of unprecedented precision (3 mrad at K = 5 mag, which represents 3 {mu} as on the sky or a centroiding precision of 10{sup -3}). The scientific potential of this mode is demonstrated by the presented observations of the circumstellar disk of the evolved Be-star 48 Lib. In addition to indirect methods such as multi-wavelength spectroscopy and polarimetry, the spectro-interferometric astrometry described here provides a new tool to directly constrain the radial density structure in the disk. For the first time, we resolve several Pfund emission lines, in addition to Br {gamma}, in a single interferometric spectrum, with adequate spatial and spectral resolution and precision to analyze the radial disk structure in 48 Lib. The data suggest that the continuum and Pf-emission originates in significantly more compact regions, inside the Br {gamma}-emission zone. Thus, spectro-interferometric astrometry opens the opportunity to directly connect the different observed line profiles of Br {gamma} and Pfund in the total and correlated flux to different disk radii. The gravitational potential of a rotationally flattened Be star is expected to induce a one-armed density perturbation in the circumstellar disk. Such a slowly rotating disk oscillation has been used to explain the well-known periodic V/R spectral profile variability in these stars, as well as the observed V/R cycle phase shifts between different disk emission lines. The differential line properties and linear constraints set by our data are consistent with theoretical models and lend direct support to the existence of a radius-dependent disk density perturbation. The data also show decreasing gas rotation velocities at increasing stellocentric radii as expected for Keplerian disk rotation, assumed by those models.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband infrared vibrational nano-spectroscopy using thermal blackbody radiation

Infrared vibrational nano-spectroscopy based on scattering scanning near-field optical microscopy (s-SNOM) provides intrinsic chemical specificity with nanometer spatial resolution. Here we use incoherent infrared radiation from a 1400 K thermal blackbody emitter for broadband infrared (IR) nano-spectroscopy.With optimized interferometric heterodyne signal amplification we achieve few-monolayer sensitivity in phonon polariton spectroscopy and attomolar molecular vibrational spectroscopy. Near-field localization and nanoscale spatial resolution is demonstrated in imaging flakes of hexagonal boron nitride (hBN) and determination of its phonon polariton dispersion relation. The signal-to-noise ratio calculations and analysis for different samples and illumination sources provide a reference for irradiance requirements and the attainable near-field signal levels in s-SNOM in general. As a result, the use of a thermal emitter as an IR source thus opens s-SNOM for routine chemical FTIR nano-spectroscopy.

36 MATERIALS SCIENCE↗

Improving Sparse-Aperture Interferometric Radiometry

Proposed method for designing spatial arrangement of antennas of sparse-aperture interferometric radiometry (SAIR) system increases spatial resolution of images produced by system. Technique involves cross-correlation of signals received by pairs of small antennas at different locations. Includes ring array of "flood-beam" antennas. Signals from all possible pairs of antennas cross-correlated simultaneously. Diameter of ring determines spatial resolution of image, and distribution of antennas around ring determines sampling characteristics. Conceived to improve proposed remote-sensing SAIR system placed in geosynchronous orbit; also applied to other SAIR systems intended to stare at stationary targets for relatively long times.

Ruf, Christopher S.↗

Comparison of Satellite Observations of Nitrogen Dioxide to Surface Monitor Nitrogen Dioxide Concentration

Nitrogen dioxide is one of the U. S. EPA s criteria pollutants, and one of the main ingredients needed for the production of ground-level ozone. Both ozone and nitrogen dioxide cause severe public health problems. Existing satellites have begun to produce observational data sets for nitrogen dioxide. Under NASAs Earth Science Applications Program, we examined the relationship between satellite observations and surface monitor observations of this air pollutant to examine if the satellite data can be used to facilitate a more capable and integrated observing network. This report provides a comparison of satellite tropospheric column nitrogen dioxide to surface monitor nitrogen dioxide concentration for the period from September 1996 through August 1997 at more than 300 individual locations in the continental US. We found that the spatial resolution and observation time of the satellite did not capture the variability of this pollutant as measured at ground level. The tools and processes developed to conduct this study will be applied to the analysis of advanced satellite observations. One advanced instrument has significantly better spatial resolution than the measurements studied here and operates with an afternoon overpass time, providing a more representative distribution for once-per-day sampling of this photochemically active atmospheric constituent.

Kleb, Mary M.↗

Flood Detection with Synthetic Aperture Radar: A Case Study of Houston, Texas Following Hurricane Harvey (2017) using C- and X-Band Observations

Hurricane Harvey produced record-breaking rainfall of up to 60 inches resulting in extensive flooding in Houston, Texas, in late August and early September of 2017. The slow forward motion of the storm following landfall left much of the area unobservable to optical remote sensing instruments for several days due to cloud cover. The active nature of Synthetic Aperture Radar (SAR) instruments allows for observations through clouds, which can supplement efforts to estimate hurricane-induced flood impacts. A growing fleet of SAR constellations has helped lower the latency of imagery following a hurricane, allowing for more timely detections of flooding to help support emergency response efforts. In this study, we leverage publicly available C-band SAR observations from the European Space Agency’s Sentinel-1B (S1B) satellite, collected on 30 August, and X-band SAR imagery collected on 1 September by the Airbus TanDEM-X (TDX) satellite made available through the NASA Commercial Smallsat Data Acquisition (CSDA) program. For each dataset, one co-polarized, StripMap, Radiometric Terrain Corrected (RTC) image was used to create a binary water/no water classification map by referencing permanent water in the Cropland Data Layer (CDL) dataset to determine thresholds. A validation dataset of randomly distributed “ground truth” points was generated using optical imagery from PlanetScope on 31 August, where the domain had relatively little cloud cover. We found that the S1B- and TDX-derived open water maps achieved overall accuracies of 94.17% and 91.57%, respectively. The variation in performance is attributed to both the penetrative abilities of C- and X-band SAR wavelengths in vegetated areas and the increased spatial resolution of the commercial SAR (~3 m) over Sentinel-1 (30 m). While publicly available Sentinel-1 observations are commonly relied upon in response and recovery efforts, these results suggest that including commercial X-band SAR imagery could be beneficial by providing both increased spatial resolution and more frequent revisits when deriving post-event flood mapping products.

Alexander M Melancon↗

Tip-Enhanced Raman Scattering on Both Sides of the Schrödinger Equation

We report historically, molecular spectroscopists have focused their attention to the right-hand side of the Schrödinger equation. Our major goal had and still has to do with determining a (bio)molecular system’s Hamiltonian operator. From a theoretical spectroscopist’s perspective, this entails varying the parameters of a model Hamiltonian until the predicted observables agree with their experimental analogues. In this context, less emphasis has been put on the left-hand side of the equation, where the interplay between a system and its immediate local environment is described. The latter is particularly meaningful and informative in modern applications of optical microscopy and spectroscopy that take advantage of surface plasmons to enhance molecular scattering cross-sections and to increase the attainable spatial resolution that is classically limited by diffraction. Indeed, the manipulation of light near the apex of a metallic nanotip has enabled single molecule detection, identification, and imaging. The distinct advantages of the so-called tip-enhanced optical nanospectroscopy/nanoimaging approaches are self-evident: ultrahigh spatial resolution (nanometer or better) and ultimate sensitivity (down to yoctomolar) are both attainable, all while retaining the ability to chemically fingerprint one molecule at a time (e.g., through Raman scattering). An equally interesting aspect of the same approach stems from using the properties of a single molecule to characterize the local environment in which it resides. This concept of single molecule spectroscopy on the left-hand side of the Schrödinger equation is certainly not novel and has been discussed in pioneering single molecule studies that ultimately led to a Nobel prize in chemistry. That said, local environment mapping through ultrasensitive optical spectroscopy acquires a unique flavor when executed using tip-enhanced Raman scattering (TERS). This is the subject of this Account.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A liquid VI scintillator cell for fast-gated neutron imaging

Here, the design of a new fast-gated neutron imaging system for the National Ignition Facility with much stricter timing constraints than a previous system has prompted the search for a fast scintillator material that can be used in imaging. A novel imaging cell based on Liquid VI has recently been developed with Eljen Technology and characterized at the Special Technologies Laboratory and the Los Alamos Neutron Science Center. The results show superior timing characteristics and spatial resolution, and sufficient light production for the new system compared to fast plastic scintillators previously used in neutron imaging. While the primary application is in inertial confinement fusion diagnostics, the imaging cell can be used in any fast-gated imaging application where timing characteristics and spatial resolution are of concern.

47 OTHER INSTRUMENTATION↗

Machine-Learning Enabled Evaluation of Probability of Piping Degradation In Secondary Systems of Nuclear Power Plants

The transition to condition-based, risk-informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for the majority of nuclear power generation costs. Furthermore, of the operations and maintenance costs in U.S. plants, approximately 80% are labor costs. To address the issue of rising operating costs and economic viability, technologies used to perform online monitoring of piping and other secondary system structural components in commercial nuclear power plants (NPPs) are under evaluation. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real time measurements, rather than at a pre-determined inspection interval thus reducing the maintenance cost. This paper describes distributed high-temperature stable fiber sensors fabricated in optical fibers through a roll-to-roll laser direct writing process using femtosecond lasers. Using phase-sensitive optical time domain reflectometry, distributed acoustic and vibration sensors can be developed and deployed to critical components and systems in NPPs to perform active measurements with spatial resolution down to 0.5-meter throughout the piping systems. Complex acoustic and vibration signatures harnessed by distributed sensors are registered and analyzed by artificial intelligence algorithms for degradation detection and flaw identification. Piping elbows with machined-in flaws were instrumented with fiber sensors. High-spatial-resolution data were used to develop and validate machine learning algorithms, including both linear and nonlinear regression, and classification. Additionally, classification and sensor analysis were also performed for data analysis. The paper concludes with recommendations and future work on applications of machine learning enabled high-resolution fiber sensors for piping degradation monitoring in current or future NPPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Assessment of Acoustic Scattering and Shielding by Time Domain Boundary Integral Equation Solutions

Based on the time domain boundary integral equation formulation of the linear convective wave equation, a computational tool dubbed Time Domain Fast Acoustic Scattering Toolkit (TD-FAST) has recently been under development. The time domain approach has a distinct advantage that the solutions at all frequencies are obtained in a single computation. In this paper, the formulation of the integral equation, as well as its stabilization by the Burton-Miller type reformulation, is extended to cases of a constant mean flow in an arbitrary direction. In addition, a "Source Surface" is also introduced in the formulation that can be employed to encapsulate regions of noise sources and to facilitate coupling with CFD simulations. This is particularly useful for applications where the noise sources are not easily described by analytical source terms. Numerical examples are presented to assess the accuracy of the formulation, including a computation of noise shielding by a thin barrier motivated by recent Historical Baseline F31A31 open rotor noise shielding experiments. Furthermore, spatial resolution requirements of the time domain boundary element method are also assessed using point per wavelength metrics. It is found that, using only constant basis functions and high-order quadrature for surface integration, relative errors of less than 2% may be obtained when the surface spatial resolution is 5 points-per-wavelength (PPW) or 25 points-per-wavelength squared (PPW2).

Hu, Fang Q.↗

Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Here, three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional localization of nanoscale battery reactions using soft X-ray tomography

Battery function is determined by the efficiency and reversibility of the electrochemical phase transformations at solid electrodes. The microscopic tools available to study the chemical states of matter with the required spatial resolution and chemical specificity are intrinsically limited when studying complex architectures by their reliance on two-dimensional projections of thick material. Here in this paper, we report the development of soft X-ray ptychographic tomography, which resolves chemical states in three dimensions at 11 nm spatial resolution. We study an ensemble of nano-plates of lithium iron phosphate extracted from a battery electrode at 50% state of charge. Using a set of nanoscale tomograms, we quantify the electrochemical state and resolve phase boundaries throughout the volume of individual nanoparticles. These observations reveal multiple reaction points, intra-particle heterogeneity, and size effects that highlight the importance of multi-dimensional analytical tools in providing novel insight to the design of the next generation of high-performance devices.

25 ENERGY STORAGE↗

Fuzzy inference enhanced information recovery from digital PIV using cross-correlation combined with particle tracking

Particle Image Velocimetry provides a means of measuring the instantaneous 2-component velocity field across a planar region of a seeded flowfield. In this work only two camera, single exposure images are considered where both cameras have the same view of the illumination plane. Two competing techniques which yield unambiguous velocity vector direction information have been widely used for reducing the single exposure, multiple image data: cross-correlation and particle tracking. Correlation techniques yield averaged velocity estimates over subregions of the flow, whereas particle tracking techniques give individual particle velocity estimates. The correlation technique requires identification of the correlation peak on the correlation plane corresponding to the average displacement of particles across the subregion. Noise on the images and particle dropout contribute to spurious peaks on the correlation plane, leading to misidentification of the true correlation peak. The subsequent velocity vector maps contain spurious vectors where the displacement peaks have been improperly identified. Typically these spurious vectors are replaced by a weighted average of the neighboring vectors, thereby decreasing the independence of the measurements. In this work fuzzy logic techniques are used to determine the true correlation displacement peak even when it is not the maximum peak on the correlation plane, hence maximizing the information recovery from the correlation operation, maintaining the number of independent measurements and minimizing the number of spurious velocity vectors. Correlation peaks are correctly identified in both high and low seed density cases. The correlation velocity vector map can then be used as a guide for the particle tracking operation. Again fuzzy logic techniques are used, this time to identify the correct particle image pairings between exposures to determine particle displacements, and thus velocity. The advantage of this technique is the improved spatial resolution which is available from the particle tracking operation. Particle tracking alone may not be possible in the high seed density images typically required for achieving good results from the correlation technique. This two staged approach offers a velocimetric technique capable of measuring particle velocities with high spatial resolution over a broad range of seeding densities.

Wernet, Mark P.↗

Movement of water vapor in the atmosphere measured by an imaging spectrometer at Rogers Dry Lake, CA

Movement of water as vapor in the atmosphere is a fundamental process in the Earth's hydrological cycle. Investigations of spatial and time scales of water vapor transport in the atmosphere are important areas of research. Water vapor transmits energy as a function of its abundance across the spectrum. This is shown in the 400- to 2500-nm spectral region where the transmission of the terrestrial atmosphere has been modeled using the MODTRAN radiative transfer code for a range of water vapor abundances. Based on these model results, spectra measured by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) have been used to investigate the movement of water vapor at 20-m spatial resolution over an 11-by-30-km area at approximately 15-minute time intervals (1.25 hours total). AVIRIS measures the upwelling spectral radiance from 400 to 2500 nm at 10-nm spectral intervals and collects images of 11-by-up-to-1000 km at 20-m spatial resolution. Data are collected at a rate of 1 km of flight line per 4.5 seconds. A set of five AVIRIS flight lines was acquired in rapid succession over Rogers Dry Lake, CA on May 18, 1993 at 18:59, 19:13, 19:29, 19:47, and 19:59 UTC. Rogers Dry lake is located 2 hours north of Los Angeles, CA at 34.84 degrees north latitude and 117.83 degrees west longitude in the Mojave Desert.

Green, Robert O.↗

Absolute calibration of the continuum x-ray spectrometer (ConSpec) at the National Ignition Facility

We illustrate the absolute calibration of the continuum x-ray spectrometer (ConSpec), designed to measure the hot-spot electron temperature of inertial confinement fusion (ICF) implosions at the National Ignition Facility (NIF). The spectrometer measures emission from photon energies of 20 to 30 keV where opacity effects in ICF implosions at the NIF are negligible and provides spatial resolution to separate the hot-spot emission from other x-ray sources, such as the gold emission from the hohlraum wall. Using a combination of x-ray ray tracing and calibration data taken using a well characterized x-ray source, we measure the dispersion, spatial resolution, and absolute sensitivity of the instrument. Finally, we present an example spectrum measured at the NIF and demonstrate the ability to measure the hot-spot electron temperature with uncertainty under 10%.

47 OTHER INSTRUMENTATION↗

Cluster evolution and microwave source counts

We present the modeled counts for the expected Sunyaev-Zel'dovich microwave sources associated with clusters of galaxies, predicted for experiments with arcminute-scale spatial resolution, assuming self-similar cluster evolution, for different spectra of the primordial density fluctuations and values of the cosmological density parameter Omega. Our simulations show that the source counts should be a powerful test of the evolution of very high redshift clusters. Experiments with 1 - 2 min spatial resolution, with moderate sensitivity but covering a large area of the sky, would be most effective for studying the SZ source population. Recent arcminute-scale radio experiments, the Owens Valley Radio Observatory (OVRO) RING experiment and VLA deep imaging, achieved sensitivity and sky coverage close to that needed for the detection of negative sources associated with very distant clusters. From the absence of cluster detections in these experiments, we rule out, with 90% confidence, models with Omega less than 0.3 and n = +1 as predicting too many bright sources; or there is no hot gas in clusters more distant than z(sub max) = 5 in such models. If the single negative source detected in the RING experiment is a distant cluster, the Omega = 1, n = -2 model also may be ruled out as it predicts too few sources. The new generation of telescopes, including the new SUZIE and Ryle instruments, will soon be able to detect distant clusters. The cluster population in the past has been modeled by scaling the observed present-day sample of X-ray clusters back to high redshifts, an approach which makes the best use of the observed cluster gas parameters, and makes the simulations robust to the assumed evolution at very early epochs. Although the pure self-similar model may be incompatible with the variety of observed evolutionary effects, we show that reasonable modifications to the intracluster gas history in that model, proposed to reconcile the self-similar evolution of cluster mass and the observed evolution of their X-ray luminosity, do not considerably change our microwave predictions made using the pure self-similar model. That is, the results of our simulations are applicable to the wide class of evolutionary models in which the cluster gas mass times gas temperature evolves as the dark mass times cluster virial temperature.

Markevitch, M.↗

The HYDROS Mission: Requirements and Baseline System Design

The HYDROS mission is under development by NASA as part of its Earth System Science Pathfinder (ESSP) program. HYDROS is designed to provide global maps of the Earth's soil moisture and freezel/thaw state every 2-3 days, for weather and climate prediction, water and carbon cycle studies, natural hazards monitoring, and national security applications. HYDROS uses a unique active and passive L-band microwave system that optimizes measurement accuracy, spatial resolution, and coverage. It provides measurements in nearly all weather conditions, regardless of solar illumination. The designs of the radar and radiometer electronics, antenna feedhorn and reflector, and science data system, are driven by specific mission and science objectives. These objectives impose requirements on the frequencies, polarizations, sampling, spatial resolution, and accuracy of the system. In this paper we describe the HYDROS mission requirements, baseline design, and measurement capabilities.

soil moisture↗