Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Characterization of SuperCDMS 1-inch Ge Detectors

The newly commissioned SuperCDMS Soudan experiment aims to search for WIMP dark matter with a sensitivity to cross sections of 5x10{sup -45}cm{sup 2} and larger (90% CL upper limit). This goal is facilitated by a new set of germanium detectors, 2.5 times more massive than the ones used in the CDMS-II experiment, and with a different athermal phonon sensor layout that eliminates radial degeneracy in position reconstruction of high radius events. We present characterization data on these detectors, as well as improved techniques for correcting position-dependent variations in pulse shape across the detector. These improvements provide surface-event discrimination sufficient for a reach of 5x10{sup -45}cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IR Photodetectors Based on Isoperiodic Epitaxial Layers of Lead Tin Chalcogenides

IR photodetectors have been made on Pb/δ-layer/p-Pb{sub 1 –x}Sn{sub x}Te{sub 1 –y}Se{sub y}/p{sup +}-Pb{sub 0.8}Sn{sub 0.2}Te/Au and Au/δ-layer/n-Pb{sub 1 –x}Sn{sub x}Te{sub 1 –y}Se{sub y}(BaF{sub 2})/Pb surface-barrier structures prepared by liquid-phase epitaxy and thermal evaporation. At ~170 K, peak wavelength λ{sub p} ~ 7.9–8.2 μm, and cutoff wavelength λ{sub c} ~ 8.2–8.5 μm, the former surface-barrier structure has product R{sub 0}A (where R{sub 0} is the zero-bias differential resistance and A is the active surface area) = 0.31–0.97 Ω cm{sup 2}, peak quantum efficiency η{sub λ} = 0.32–0.48, and specific detectability D{sub λ}{sup ∗} = (0.72–1.83) × 10{sup 10} cm Hz{sup 1/2} W{sup –1}. For photodiodes made on the latter surface-barrier structure, these parameters measured at ~80 K are R{sub 0}A = 1.71–2.72 Ω cm{sup 2}, η{sub λ} = 0.34–0.49, and D{sub λ}{sup ∗} = (3.02–4.51) × 10{sup 10} cm Hz{sup 1/2} W{sup –1} at λ{sub p} ~ 8.6–12.3 μm and λ{sub c} ~ 9.2–12.9 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time evolution of negative ion profile in a large cesiated negative ion source applicable to fusion reactors

To understand the physics of the cesium (Cs) recycling in the large Cs-seeded negative ion sources relevant to ITER and JT-60SA with ion extraction area of 45-60 cm × 110-120 cm, the time evolution of the negative ion profile was precisely measured in JT-60SA where the ion extraction area is longitudinally segmented into 5. The Cs was seeded from the oven at 180 °C to the ion source. After 1 g of Cs input, surface production of the negative ions appeared only in the central segment where a Cs nozzle was located. Up to 2 g of Cs, the negative ion profile was longitudinally expanded over full ion extraction area. The measured time evolution of the negative ion profile has the similar tendency of distribution of the Cs atoms that is calculated. From the results, it is suggested that Cs atom distribution is correlated with the formation of the negative ion profile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Lattice Boltzmann Scheme for Polarized Radiative Transfer in Planetary Atmospheres

Quantitative calculation of reflected polarized light from planets is of great significance to interpret the polarimetric observations of planetary atmospheres. In this work, we propose a lattice Boltzmann (LB) scheme for polarized radiative transfer in planetary atmospheres. The LB scheme obtains the Stokes vector through the vector LB equation performing simple collision and streaming processes. The vector radiative transfer equation is rigorously derived from the vector LB equation via the Maxwell iteration technique. Polarized radiative transfer of a single point on the planetary surface with Rayleigh and Mie scattering atmospheres are first accurately solved by our LB scheme. Afterward, we systematically investigate the disk-integrated polarization of finite and semi-infinite, conservative and nonconservative Rayleigh scattering planetary atmospheres. The disk-integrated phase curves of the Stokes parameters and degree of polarization and spherical and geometric albedos are produced, which are in good agreement with the benchmark results for different cases. The numerical results indicate that our LB scheme is efficient and accurate for polarized radiative transfer in planetary atmospheres. Our LB scheme is expected to provide a competitive numerical tool to interpret the polarimetric observations of planetary atmospheres.

47 OTHER INSTRUMENTATION↗

Over three decades, and counting, of near-surface turbulent flux measurements from the Atmospheric Radiation Measurement (ARM) user facility

Processes mediating the coupling of terrestrial, aquatic, biospheric, and atmospheric systems influence weather, climate, and ecosystem dynamics via transfer of energy, momentum, water, and carbon (or other species). These exchange processes are quantified by measurements of near-surface turbulent fluxes. Understanding processes at these interfaces provides insight toward understanding and predicting current and future states within the Earth system. The Atmospheric Radiation Measurement (ARM) user facility has been conducting measurements of near-surface turbulent fluxes since the early 1990s at long-term fixed locations and shorter-term mobile deployments across the Earth. ARM has utilized two established methods for conducting these measurements: energy balance Bowen ratio (EBBR) and eddy covariance (EC). Primary measurements from the former include sensible and latent heat flux, while the latter also measures fluxes of momentum and carbon (primarily carbon dioxide, with methane fluxes measured at two locations to date). The EBBR systems have been deployed at 22 locations, and, to date, the EC systems have been deployed at over 50 sites, with plans for additional novel site locations in the future. Herein, the history, evolution, and key aspects of these instrument systems are documented, along with information on data quality assurance and post-processing, as well as best use practices. Additionally, three data validation experiments were recently conducted, and their key findings are summarized. Finally, ancillary datasets acquired by ARM, which can contextualize and aid interpretation of the near-surface turbulent flux measurements, are discussed. The datasets described herein include the eddy correlation flux measurement system: 30ECOR (https://doi.org/10.5439/1879993, Sullivan et al., 1997), 30QCECOR (https://doi.org/10.5439/1097546, Gaustad, 2003), ECORSF (https://doi.org/10.5439/1494128, Sullivan et al., 2019a), and associated AmeriFlux and Methane Value-Added Product, AMCMETHANE (https://doi.org/10.5439/1508268, Billesbach, 2011); the energy balance Bowen ratio system: 30EBBR (https://doi.org/10.5439/1023895, Sullivan et al., 1993) and 30BAEBBR (https://doi.org/10.5439/1027268, Gaustad and Xie, 1993); and the carbon dioxide flux measurement system: CO2FLX (https://doi.org/10.5439/1287574, https://doi.org/10.5439/1287575, https://doi.org/10.5439/1287576, Koontz et al., 2015a, b, c; https://doi.org/10.5439/1989774, https://doi.org/10.5439/1989776, https://doi.org/10.5439/1992202, Biraud and Chan, 2002a, b, c). These data can be found by searching the above data stream names at https://adc.arm.gov/discovery/#/results/ (last access: 8 September 2025).

Sullivan, Ryan C. [Argonne National Laboratory (AN↗

Tree-ring evidence marks year 2022 as the driest spring season in nearly four centuries in the Western Himalayas

The Hindukush-Karakoram-Himalayan region is a crucial freshwater source for billions across South Asia, yet its climate remains poorly understood due to limited long-term records. Winter and spring precipitation govern snow accumulation and downstream water availability in dry months particularly across the Western Himalayas (WH), but recent decades show intensifying droughts with unclear long-term context. Here, we have reconstructed a nearly four-century-long spring i.e. February to May (FMAM) precipitation for the Lahaul region of the (WH), an area dominated by the Western Disturbances. This record was developed using moisture-sensitive Cedrus deodara (Deodar) tree-rings from three high-elevation sites. A regional composite tree-ring-width chronology, developed through a Nested Principal Component Analysis and modeled with a nonlinear Generalized Additive Model (GAM) that explains 71 % of the variance during the calibration period. We identified the last two decades as the most precipitation deficit phase and the year 2022 showing the driest FMAM on record. The observed rise in the FMAM dry episodes post 1999 CE in our reconstruction, corresponds to the meteorological records. This recent drying is linked to a northward shift of the subtropical westerly jet and reduced moisture transport, both associated with unusual sea surface temperature patterns in the tropical Indian Ocean and the Western Pacific Ocean. Our results provide compelling evidence of long-term hydroclimatic instability in the WH and emphasize the value of tree-ring records in extending precipitation histories beyond the instrumental observations. Such reconstructions can be benchmarks to validate high-resolution climate models and formulate adaptation policies to mitigate future risks.

Cedrus deodara↗

Setup for optimized grazing incidence x-ray absorption experiments on thin films on substrates

We present a state-of-the-art experimental apparatus and a proper setup to perform x-ray absorption spectroscopy (XAS) experiments in grazing incidence mode. This geometry is appropriate for doped thin films or interfaces buried at moderate depth in a thick matrix, whenever the scattering and/or fluorescence from the matrix has to be strongly attenuated. Both the calculation and the experimental data demonstrate that the specific setup that consists in a grazing incidence and grazing collection geometry is extremely advantageous. In fact, with respect to the standard geometry used to perform XAS experiments in fluorescence mode, the present setup allows an enhancement in the interesting fluorescence signal from the surface layer without a corresponding increase in the elastic scattering contribution from the matrix. The sample holder especially designed for this kind of experiment can work in vacuum and at low temperature. An easy and quick automatic sample alignment procedure is detailed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A synthetic diagnostic for beam emission spectroscopy in the helically symmetric experiment stellarator

The Helically Symmetric Experiment (HSX) has a number of active spectroscopy diagnostics. Due to the relatively large beam width compared to the plasma minor radius, it is difficult to achieve good spatial resolution at the core of the HSX plasma. This is due to the fact that the optical sightline cuts through many flux surfaces with varying field vectors within the beam. In order to compare the experimental results with theoretical models it is important to accurately model the beam width effects. A synthetic diagnostic has been developed for this purpose. This synthetic diagnostic calculates the effect of spot size and beam width on the measurements of quantities of interest, including radial electric field, flow velocity, and Stark polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultraviolet photodissociation of C{sub 2}F{sub 5}I with a small and simple photofragment translational spectrometer

Photodissociation dynamics of C{sub 2}F{sub 5}I near 280 and 304 nm has been investigated on a small and simple time-of-flight photofragment translational spectrometer (PTS). On this new PTS, the photolyzed and ionized fragments, not accelerated by electric field, travel freely for a short flight path (<50 mm) and are detected by microchannel plates. In the spectra of the I*({sup 2}P{sub 1/2}) channel at 281.73 and 304.02 nm, vibrational peaks with spacing of {approx}350 cm{sup -1} are partially resolved, indicating the preferential excitation of CF{sub 2} wag mode ({nu}{sub 11}=366 cm{sup -1}) of C{sub 2}F{sub 5} photofragment. The fraction of the available energy disposed into the internal energy is higher than 50% for both I{sup *} channel and I channel, showing the high excitation of vibration in the C{sub 2}F{sub 5} fragments. The fragment recoil anisotropy parameter {beta}(I{sup *}), determined to be 1.70 at 281.73 nm and 1.64 at 304.02 nm, reveals that I* atoms are produced predominantly from the parallel {sup 3}Q{sub 0}<-N transition. The anisotropy parameter {beta}(I), determined to be 1.25 at 279.71 nm and 0.88 at 304.67 nm, implies that I atoms are produced from two excited states, i.e., direct dissociation via the perpendicular {sup 3}Q{sub 1}(leftarrow)N transition, and indirect dissociation via the parallel {sup 3}Q{sub 0}(leftarrow)N transition then curve crossing to the {sup 1}Q{sub 1} potential energy surface. Analysis on the recent studies with vibrational state resolution in the photodissociation of alkyl iodides in the A band reveals that the ''symmetric bending'' mode on {alpha}-carbon of alkyl iodides is the preferential vibrational excitation mode, which can be explained by the classic impulsive model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Confocal simultaneous phase-shifting interferometry

In order to implement the ultraprecise measurement with large range and long working distance in confocal microscopy, confocal simultaneous phase-shifting interferometry (C-SPSI) has been presented. Four channel interference signals, with {pi}/2 phase shift between each other, are detected simultaneously in C-SPSI. The actual surface height is then calculated by combining the optical sectioning with the phase unwrapping in the main cycle of the interference phase response, and the main cycle is determined using the bipolar property of differential confocal microscopy. Experimental results showed that 1 nm of axial depth resolution was achieved for either low- or high-NA objective lenses. The reflectivity disturbance resistibility of C-SPSI was demonstrated by imaging a typical microcircuit specimen. C-SPSI breaks through the restriction of low NA on the axial depth resolution of confocal microscopy effectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam profile and coherence properties of synchrotron beams after reflection on modified multilayer mirrors

Multilayer mirrors present an attractive alternative for reflective hard X-ray monochromators due to their increased bandwidth compared with crystal-based systems. An issue remains the strong modulations in the reflected beam profile, i.e. an irregular stripe pattern. This is a major problem for micro-imaging applications, where multilayer-based monochromators are frequently employed to deliver higher photon flux density. A subject of particular interest is how to overcome beam profile modifications, namely the stripe patterns, induced by the reflection on a multilayer. For multilayer coatings in general it is known that the substrate and its surface quality significantly influence the performance of such kind of mirrors as the coating reproduces to a certain degree roughness and shape of the substrate. Our studies have shown that modified coatings can significantly change the impact of the multilayer reflection on the beam profile. We will present recent results as well as a critical review.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-138: An IGRT QA Device for Measuring with Tenths-Millimeter Accuracy KV and MV Isocenter Congruence, Couch Travel and Laser Alignment of Accelerators Used for SRS and SBRT

Purpose: To develop a practical device having sufficient accuracy for daily QA tests of accelerators used for SRS and SBRT. Methods: The UAB (Universal Alignment Ball) consists of a 6.35 mm (1/4 inch) diameter tungsten sphere located concentrically within a 25.4 mm (1 inch) diameter acrylic plastic (PMMA) sphere. The spheres are embedded in polystyrene foam, which, in turn, is surrounded by a cylindrical PMMA shell. The UAB is placed on the couch and aligned with wall lasers according to marks that have known positions in relation to the center of the spheres. Using planar and cone beam images the couch is shifted till the surface of the PMMA sphere matches Eclipse-generated circular contours. Anterior and lateral MV images taken with small MLC openings allow measurement of distance between kV and MV isocenter, laser and MLC alignment. Measurements were taken over a one-month period. Results: Artifacts from the tungsten sphere were confined within the PMMA sphere and did not affect cone beam localization of the sphere boundary, allowing 0.1 mm precise alignment with a computer-generated circle centered at kV isocenter. In tests extending over a one-month period, the distance between kV and MV isocenters along the vertical, longitudinal and lateral directions was 0.125 +/−0.06, 0.19 +/−0.08, and 0.02 +/−0.08 mm, respectively. Laser misalignment along these directions was 0.34 +/- 0.15, 0.74 +/−0.29, and 0.49 +/−0.22 mm. Automated couch shifts moved the spheres to within 0.1 mm of the selected position. The center of a 1cmx1cm MLC-defined field remained within +/−0.2 mm of the tungsten sphere center as the gantry was rotated. Conclusion: The UAB is practical for daily end-to-end QA tests of accelerator alignment. It provides tenths-mm accuracy for measuring agreement of kV and MV isocenters, couch motions, gantry flex and laser alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Chemistry of Ultra-Radiopure Materials

Ultra-pure materials are needed for the construction of the next generation of ultra-low level radiation detectors. These detectors are used for environmental research as well as rare nuclear decay experiments, e.g. probing the effective mass and character of the neutrino. Unfortunately, radioactive isotopes are found in most construction materials, either primordial isotopes, activation/spallation products from cosmic-ray exposure, or surface deposition of dust or radon progeny. Copper is an ideal candidate material for these applications. High-purity copper is commercially available and, when even greater radiopurity is needed, additional electrochemical purification can be combined with the final construction step, resulting in “electroformed” copper of extreme purity. Copper also offers desirable thermal, mechanical, and electrical properties. To bridge the gap between commercially-available high purity copper and the most stringent requirements of next-generation low-background experiments, a method of additional chemical purification is being developed based on well-known copper electrochemistry. This method is complemented with the co-development of surface cleaning techniques and more sensitive assay for both surface and bulk contamination. Developments in the electroplating of copper, surface cleaning, assay of U and Th in the bulk copper, and residual surface contamination will be discussed relative to goals of less than 1 microBq/kg Th.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of window reflections on photonic Doppler velocimetry measurements

Photonic Doppler velocimetry (PDV) has rapidly become a standard diagnostic for measuring velocities in dynamic compression research. While free surface velocity measurements are fairly straightforward, complications occur when PDV is used to measure a dynamically loaded sample through a window. Fresnel reflections can severely affect the velocity and time resolution of PDV measurements, especially for low-velocity transients. Shock experiments of quartz compressed between two sapphire plates demonstrate how optical window reflections cause ringing in the extracted PDV velocity profile. Velocity ringing is significantly reduced by using either a wedge window or an antireflective coating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of the plasma to the size of an anode electrode biased near the plasma potential

As the size of a positively biased electrode increases, the nature of the interface formed between the electrode and the host plasma undergoes a transition from an electron-rich structure (electron sheath) to an intermediate structure containing both ion and electron rich regions (double layer) and ultimately forms an electron-depleted structure (ion sheath). In this study, measurements are performed to further test how the size of an electron-collecting electrode impacts the plasma discharge the electrode is immersed in. This is accomplished using a segmented disk electrode in which individual segments are individually biased to change the effective surface area of the anode. Measurements of bulk plasma parameters such as the collected current density, plasma potential, electron density, electron temperature and optical emission are made as both the size and the bias placed on the electrode are varied. Abrupt transitions in the plasma parameters resulting from changing the electrode surface area are identified in both argon and helium discharges and are compared to the interface transitions predicted by global current balance [S. D. Baalrud, N. Hershkowitz, and B. Longmier, Phys. Plasmas 14, 042109 (2007)]. While the size-dependent transitions in argon agree, the size-dependent transitions observed in helium systematically occur at lower electrode sizes than those nominally derived from prediction. The discrepancy in helium is anticipated to be caused by the finite size of the interface that increases the effective area offered to the plasma for electron loss to the electrode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

Tall Tower Wind Energy Monitoring and Numerical Model Validation in Northern Nevada

The main objectives of this project were to conduct a tall-tower and sodar field campaign in complex terrain, investigate wind properties relevant to wind energy assessment, and evaluate high-resolution models with fixed and adaptive grid structures. Two 60-m towers at Virginia Peak ridges near Washoe Valley, Nevada, were instrumented with cup and vane anemometers as well as sonic anemometers, and an acoustic sounder (hereafter sodar) was installed near one of the towers. The towers were located 2,700 m apart with a vertical distance of 140 m elevation between their bases. Each tower had a downhill exposure of rolling complex terrain, with the nearby valley floor 3,200 m to the west and 800 m below the summit. Cup anemometers were installed at both towers at 20, 40, and 60 m, wind vanes at 20 and 60 m, and sonic anemometers at 20 and 60 m. The sodar measurements were nominally provided every 10 m in vertical distance from 40 to 200 m with the quality of the data generally decreasing with height. Surface air temperature, atmospheric pressure, and radiation measurements were conducted at 1.5 m AGL at both of the towers. Although the plan was to conduct a 1-year period of data collection, we extended the period (October 5, 2012 through February 24, 2014) to cover for possible data loss from instrument or communication problems. We also present a preliminary analysis of the towers and sodar data, including a detailed inventory of available and missing data as well as outliers. The analysis additionally includes calculation of the Weibull parameters, turbulence intensity, and initial computation of wind power density at various heights.

17 WIND ENERGY↗

Compact solid-state neutral particle analyzer in current mode

Solid state neutral particle analyzer (ssNPA) arrays are operated in current mode on the DIII-D tokamak and the National Spherical Torus Experiment (NSTX). Compared with conventional pulse-counting NPAs, current-mode operation sacrifices energy resolution to obtain economical, high-bandwidth, pitch-angle resolved measurements. With the success from a new three-channel near-vertical-view current mode ssNPA on DIII-D, the apertures on an existing array on NSTX were expanded to increase the particle influx. The sightlines of both arrays intersect heating beams, enabling both active and passive charge exchange measurements. The spatial resolution at beam intersection is typically 5 cm on both devices. Directly deposited ultra-thin foils on the detector surface block stray photons below the energy of 1 keV and also set low energy threshold about 25 keV for deuterium particle detection. Oscillations in neutral flux produced by high frequency magnetohydrodynamics (MHD) instabilities are readily detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗