Search NASA⌕ Search

SEARCH · Search NASA

Results for “test correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Connecting ambient toxicity testing with community-level responses of benthic macroinvertebrates in an impacted stream in East Tennessee, USA

Single-species laboratory toxicity tests are a standard tool for evaluating potential impairment of freshwater systems; however, it remains uncertain how well they reflect community-level impacts in natural environments. This study presents a multi-decadal dataset (2005-2025) pairing ambient toxicity testing with macroinvertebrate surveys along Bear Creek on the Oak Ridge Reservation (Tennessee, USA) downstream of an industrial complex to assess the ability of laboratory tests using stream water to track community-level effects. Biannual three-brood Ceriodaphnia dubia tests from 2005 to 2025 often showed reduced reproduction at select sites. Integrating water quality data showed strong positive correlations between sublethal toxicity and specific conductance. Macroinvertebrate diversity metrics, family-level occurrence, and densities were also associated with conductance and contemporaneous C. dubia responses. Laboratory-measured sublethal toxicity was a stronger indicator of macroinvertebrate change than conductance alone, although responses varied among sites and seasons. At the site with the highest diversity, densities and richness of Ephemeroptera, Plecoptera, Trichoptera (EPT) and non-EPT taxa were significantly related to C. dubia reproduction, with greater toxicity corresponding to lower diversity. At the family level, some pollution-tolerant taxa were more prevalent and at higher densities during periods of sublethal toxicity, while some sensitive families were absent or reduced. These patterns may reflect site-specific mixtures of acute and chronic stressors, with laboratory toxicity tests more effectively capturing short-term impacts. Overall, these multi-decadal observations suggest that laboratory toxicity tests can help track water-quality changes linked to shifts in aquatic community diversity, despite variable responses reflecting the complexity of dynamic stressors in this impacted freshwater system.

Stevenson, Louise [ORNL] (ORCID:0000000349679897)↗

Angular systematics-free cosmological analysis of galaxy clustering in configuration space

ABSTRACT Galaxy redshift surveys are subject to incompleteness and inhomogeneous sampling due to the various constraints inherent to spectroscopic observations. This can introduce systematic errors on the summary statistics of interest, which need to be mitigated in cosmological analysis to achieve high accuracy. Standard practices involve applying weighting schemes based on completeness estimates across the survey footprint, possibly supplemented with additional weighting schemes accounting for density-dependent effects. In this work, we concentrate on pure angular systematics and describe an alternative approach consisting in analysing the galaxy two-point correlation function where angular modes are nulled. By construction, this procedure removes all possible known and unknown sources of angular observational systematics, but also part of the cosmological signal. We use a modified Landy–Szalay estimator for the two-point correlation function that relies on an additional random catalogue where angular positions are randomly drawn from the galaxy catalogue, and provide an analytical model to describe this modified statistic. We test the model by performing an analysis of the full anisotropic clustering in mock catalogues of luminous red and emission-line galaxies at 0.43 < z < 1.1. We find that the model fully accounts for the modified correlation function in redshift space, without introducing new nuisance parameters. The derived cosmological parameters from the analysis of baryon acoustic oscillations and redshift-space distortions display slightly larger statistical uncertainties, mostly for the growth rate of structure parameter fσ8 that exhibits a $50{{\ \rm per\ cent}}$ statistical error increase, but free from angular systematic error.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards TDDFT for Strongly Correlated Materials

We present some details of our recently-proposed Time-Dependent Density-Functional Theory (TDDFT) for strongly-correlated materials in which the exchange-correlation (XC) kernel is derived from the charge susceptibility obtained using Dynamical Mean-Field Theory (the TDDFT + DMFT approach). We proceed with deriving the expression for the XC kernel for the one-band Hubbard model by solving DMFT equations via two approaches, the Hirsch–Fye Quantum Monte Carlo (HF-QMC) and an approximate low-cost perturbation theory approach, and demonstrate that the latter gives results that are comparable to the exact HF-QMC solution. Furthermore, through a variety of applications, we propose a simple analytical formula for the XC kernel. Additionally, we use the exact and approximate kernels to examine the nonhomogeneous ultrafast response of two systems: a one-band Hubbard model and a Mott insulator YTiO3. We show that the frequency dependence of the kernel, i.e., memory effects, is important for dynamics at the femtosecond timescale. We also conclude that strong correlations lead to the presence of beats in the time-dependent electric conductivity in YTiO3, a feature that could be tested experimentally and that could help validate the few approximations used in our formulation. We conclude by proposing an algorithm for the generalization of the theory to non-linear response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of PACS-EMR Integration on Radiologist Usage of the EMR

The purpose of this study was to objectively quantify the impact of implementing picture archiving and communication system-electronic medical record (PACS-EMR) integration on the time required to access data in the EMR and the frequency with which data are accessed by radiologists. Time to access a clinic note in the EMR was measured before and after integration with a stopwatch and compared by t test. An IRB-approved, HIPAA-compliant retrospective review of EMR access data from security audit logs was conducted for a 14-month period spanning the integration. Correlation of these data with report signatures identified the studies in which the radiologist accessed the EMR to obtain additional clinical data. Proportions of studies with EMR access were plotted and compared before and after integration using a chi-square test. Time to access the EMR decreased from 52 to 6 s (p < 0.001). Proportion of studies with EMR access increased from 36.7% (10,175/27,773) to 44.9% (10,843/24,153) after integration (p < 0.001). Integrating PACS and the EMR substantially decreases the time to access the EMR and is associated with a significant increase in the proportion of studies for which radiologists obtain additional clinical data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis

Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice--Once supine and once prone--to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated method for colon registration from supine and prone CTC scans. Methods: We propose a new colon centerline registration method for prone and supine CTC scans using correlation optimized warping (COW) and canonical correlation analysis (CCA) based on the anatomical structure of the colon. Four anatomical salient points on the colon are first automatically distinguished. Then correlation optimized warping is applied to the segments defined by the anatomical landmarks to improve the global registration based on local correlation of segments. The COW method was modified by embedding canonical correlation analysis to allow multiple features along the colon centerline to be used in our implementation. Results: We tested the COW algorithm on a CTC data set of 39 patients with 39 polyps (19 training and 20 test cases) to verify the effectiveness of the proposed COW registration method. Experimental results on the test set show that the COW method significantly reduces the average estimation error in a polyp location between supine and prone scans by 67.6%, from 46.27{+-}52.97 to 14.98 mm{+-}11.41 mm, compared to the normalized distance along the colon centerline algorithm (p<0.01). Conclusions: The proposed COW algorithm is more accurate for the colon centerline registration compared to the normalized distance along the colon centerline method and the dynamic time warping method. Comparison results showed that the feature combination of z-coordinate and curvature achieved lowest registration error compared to the other feature combinations used by COW. The proposed method is tolerant to centerline errors because anatomical landmarks help prevent the propagation of errors across the entire colon centerline.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decarburization and Carburization Behavior of Grade 91 Steel in Sodium Environments

Two heats of G91 steel have been investigated in sodium at 550-650°C to understand its corrosion behaviour, microstructural evolution, and tensile properties. Sodium exposure tests of subsized tensile and coupon specimens of G91 base metal and weldment were conducted in Argonne’s forced convection sodium materials testing loops. Maximum exposure times of ~39,000 h at 550°C, ~37,000 h at 600°C, and ~20,000 h at 650°C have been achieved, respectively. Thermal aging experiments of G91 steel were conducted in parallel, and the data of the sodium-exposed specimens were compared with the thermal aging data of the same heat to isolate the thermal aging effect from the effect of sodium exposure. It was found that the tensile strength of G91 steel can be reduced by more than 50% after sodium exposures at 650°C. The effect of a sodium environment on tensile properties is largely dependent on the carburization/decarburization behavior of G91 steel exposed to sodium. The carbon concentrations in sodium in Argonne’s SMT-1 and SMT-2 loops were determined by the equilibration method. The carbon activity in sodium was established by equilibrating high-purity nickel in sodium, analyzing the material for carbon, and using the reported data on the carbon solubility for this material. The carbon activity results were combined with the carbon solubility data in sodium to establish the carbon concentration in sodium. The carbon concentrations in the SMT-1 and SMT-2 loop were estimated to be 1.23 and 0.25 ppm, respectively. With this initial success, we will continue to monitor the carbon contents in the two loops to correlate the microstructural and mechanical property changes with the sodium purity. Future experiments will also consider sodium exposure tests in controlled carbon activities. Online monitoring and control of carbon contents in sodium in nuclear reactors would also be of interest. Thermodynamic analysis was conducted to understand the carburization-decarburization behavior of G91 steel exposed to sodium in the SMT-1 and SMT-2 loops. The equilibrium carbon activity in the alloy was evaluated by the thermodynamics of M 23 C 6 carbides. The calculated carburization-decarburization boundary showed that G91 would undergo decarburization at 650°C in the SMT-1 loop and carburization at 600°C in the SMT-2 loop, which is consistent with our findings from the sodium exposure tests. Future work will include thermodynamic analysis of the carbon concentration – activity relationship including the effect of carbide-forming elements, vanadium and niobium in G91 steel. Kinetics of carbon diffusion and the effect on microstructure and mechanical performance under various service conditions will also be investigated. The ultimate goal is to understand the mechanisms and the kinetics of carbon transfer in the sodium-steel system and to provide a basis for predicting the effect of long-term decarburization-carburization process on the integrity of reactor components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MR texture analysis: potential imaging biomarker for predicting the chemotherapeutic response of patients with colorectal liver metastases

Purpose: The purpose of the study was to determine whether the pre-treated MR texture features of colorectal liver metastases (CRLMs) are predictive of therapeutic response after chemotherapy. Methods: The study included twenty-six consecutive patients (a total of 193 liver metastasis) with unrespectable CRLMs at our institution from August 2014 to February 2016. Lesions were categorized into either responding group or non-responding group according to changes in size. Texture analysis was quantified on T2-weighted images by two radiologists with consensus on regions of interest which were manually drawn on the largest cross-sectional area of the lesions. Five histogram features (mean, variance, skewness, kurtosis, and entropy{sup 1}) and five gray level co-occurrence matrix features (GLCM; angular second moment (ASM), entropy{sup 2}, contrast, correlation, and inverse difference moment (IDM)) were extracted. The texture parameters were statistically analyzed to identify the differences between the two groups, and the potential predictive parameters to differentiate the responding group from the non-responding group were subsequently tested using multivariable logistic regression analysis. Results: A total of 107 responding and 86 non-responding lesions were evaluated. A higher variance, entropy{sup 1}, contrast, entropy{sup 2} and a lower ASM, correlation, IDM were independently (P < 0.05) associated with a good response to chemotherapy with the areas under the ROC curves (AUCs) of 0.602–0.784. Variance (P < 0.001) and ASM (P = 0.001) remained potential predictive values to discriminate responding lesions from non-responding lesions when tested using multivariable logistic regression analysis. The highest AUC of the predictors from the association of variance and ASM was 0.814. Conclusion: MR texture features on pre-treated T2 images have the potential to predict the therapeutic response of colorectal liver metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructural strain mapping during in-situ cyclic testing of ductile iron

Highlights: • A method for quantitative study of crack formation and propagation during cyclic loading was developed. • Focused Ion Beam Milling was shown to be an effective method to generate a high quality speckle pattern for Digital Image Correlation measurements • The method enabled a high-resolution measurement of localized strain in the microstructure of ductile iron • The peak strain and the strain distribution ahead of the growing crack under load were quantified - Abstract: This paper focuses on local strain distribution in the microstructure of high silicon ductile iron during cyclic loading. In-situ cyclic test was performed on compact-tension (CT) samples inside the scanning electron microscope (SEM) to record the whole deformation and obtain micrographs for microstructural strain measurement by means of digital image correlation (DIC) technique. Focused ion beam (FIB) milling was used to generate speckle patterns necessary for DIC measurement. The equivalent Von Mises strain distribution was measured in the microstructure at the maximum applied load. The results revealed a heterogeneous strain distribution at the microstructural level with higher strain gradients close to the notch of the CT sample and accumulated strain bands between graphite particles. Local strain ahead of the early initiated micro-cracks was quantitatively measured, showing high strain localization, which decreased by moving away from the micro-crack tip. It could be observed that the peak of strain in the field of view was not necessarily located ahead of the micro-cracks tip which could be because of the (i) strain relaxation due to the presence of other micro-cracks and/or (ii) presence of subsurface microstructural features such as graphite particles that influenced the strain concentration on the surface.

36 MATERIALS SCIENCE↗

WE-D-BRE-03: Late Toxicity Following Photon Or Proton Radiotherapy in Patients with Brain Tumors

Purpose: To identify indicators of Late Grade 3 (LG3) toxicity, late vision and hearing changes in patients treated for primary brain tumors with photon (XRT) or proton radiotherapy (PRT). Methods: We retrospectively reviewed 102 patients who received brain XRT or PRT to doses of 54 or 59.6 Gy in daily fractions of 1.8–2 Gy. Of the 80 patients (34 XRT, 39 PRT and 7 both modalities) reviewed for indicators of LG3 toxicity, 25 developed LG3 toxicity 90 to 500 days after radiotherapy completion. 55 patients had less than LG3 toxicity > 500 days after treatment. In that time, late vision and hearing changes were seen in 44 of 75 and 25 of 78 patients, respectively. The correlation between late toxicity and prescription dose, planning target volume (PTV) size, and doses to the brainstem, brain, optic chiasm, optic nerves, eyes and cochlea was evaluated. A two-tailed Fisher's exact test and Wilcoxon rank sum test were used for the statistical analysis for XRT, PRT and all patients combined. Results: Exceeding the 54 Gy-5% dose-volume brainstem constraint, but not the optic structure constraints, was significantly correlated (p < 0.05) with late vision changes in all three groups. Exceeding maximum and mean cochlear doses of 45 and 30 Gy, respectively, was a significant indicator of hearing changes (p < 0.05) in PRT patients and all patients combined. In a sub-group of 52 patients in whom the brain was contoured, the absolute brain volume receiving ≤ 50 Gy and > 60 Gy was significantly larger in patients with LG3 toxicity for all patients combined (p < 0.05). Prescription dose, brainstem dose and PTV volume were not correlated to LG3 toxicity. Conclusion: Our results indicate the importance of minimizing the brain volume irradiated, and brainstem and cochlea doses to reduce the risk of late toxicities following brain radiotherapy.

60 APPLIED LIFE SCIENCES↗

THE GREEN BANK TELESCOPE MAPS THE DENSE, STAR-FORMING GAS IN THE NEARBY STARBURST GALAXY M82

Observations of the Milky Way and nearby galaxies show that dense molecular gas correlates with recent star formation, suggesting that the formation of this gas phase may help regulate star formation. A key test of this idea requires wide-area, high-resolution maps of dense molecular gas in galaxies to explore how local physical conditions drive dense gas formation, but these observations have been limited because of the faintness of dense gas tracers like HCN and HCO{sup +}. Here we demonstrate the power of the Robert C. Byrd Green Bank Telescope (GBT)—the largest single-dish millimeter radio telescope—for mapping dense gas in galaxies by presenting the most sensitive maps yet of HCN and HCO{sup +} in the starburst galaxy M82. The HCN and HCO{sup +} in the disk of this galaxy correlates with both recent star formation and more diffuse molecular gas and shows kinematics consistent with a rotating torus. The HCO{sup +} emission extending to the north and south of the disk is coincident with the outflow previously identified in CO and traces the eastern edge of the hot outflowing gas. The central starburst region has a higher ratio of star formation to dense gas than the outer regions, pointing to the starburst as a key driver of this relationship. These results establish that the GBT can efficiently map the dense molecular gas at 90 GHz in nearby galaxies, a capability that will increase further with the 16 element feed array under construction.

79 ASTRONOMY AND ASTROPHYSICS↗

Di-Jet Conical Correlations Associated with Heavy Quark Jets in anti-de Sitter Space/Conformal Field Theory Correspondence

We show that far zone Mach and diffusion wake 'holograms' produced by supersonic strings in anti-de Sitter space/conformal field theory (AdS/CFT) correspondence do not lead to observable conical angular correlations in the strict N{sub c}{yields}{infinity} supergravity limit if Cooper-Frye hadronization is assumed. However, a special nonequilibrium 'neck' zone near the jet is shown to produce an apparent sonic boom azimuthal angle distribution that is roughly independent of the heavy quark's velocity. Our results indicate that a measurement of the dependence of the away-side correlations on the velocity of associated identified heavy quark jets at the BNL Relativistic Heavy Ion Collider and CERN LHC will provide a direct test of the nonperturbative dynamics involved in the coupling between jets and the strongly coupled quark-gluon plasma implied by AdS/CFT correspondence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Azimuthal correlation function of polarized top quark in noncommutative space–time

The azimuthal correlation belongs to a class of polarization observables which vanishes at the Born term level in the standard model for the semileptonic rest frame decay of a polarized top quark t(↑)→bW{sup +}→bℓ{sup +}υ{sub ℓ}. In this frame, the azimuthal correlation is defined between the planes formed by the vectors ( p-vector {sub ℓ}, p-vector {sub X{sub b}}) and ( p-vector {sub ℓ}, P-vector {sub t}). We calculate the azimuthal correlation function of polarized top quark in the framework of the noncommutative standard model for the first time. We find that this observable is nonzero in the leading order of noncommutative space–time. Further the appearance of the oscillatory azimuthal distribution of decay rate provides a practical possibility to test the noncommutativity in particle colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correlating microstructure and mechanical properties of harvested high dose Zorita light water reactor internals

Here, in this study, microstructural studies and micro-mechanical testing of an ex-plant material harvested from the decommissioned pressurized water reactor (PWR) is carried out. Irradiated 304 stainless steel (SS) components were harvested by the Electric Power Research Institute, U.S. Nuclear Regulatory Commission, and members of the José Cabrera Nuclear Power Station (Zorita) in Spain. The bi-crystalline micro-tensile specimens, atom probe tomography (APT) tips, and transmission electron microscopy (TEM) lamellae were fabricated from the baffle plate materials irradiated to 0.05, 15 and 50 dpa to elucidate microstructural, microchemical, and local mechanical properties changes as a function of dose. TEM and APT studies reveal radiation induced Ni, Cr, and Si rich precipitates in the 15 dpa sample that become smaller and partially redissolve into the matrix of the 50 dpa sample (decreasing size and number density). Dislocation loop and cavity number density and size were quantified as a function of dose as well as swelling. Intergranular Ni and Si enrichments with concomitant Fe and Cr depletion were observed in the 15 dpa sample and were more pronounced in the 50 dpa sample. Micro-tensile testing performed in the scanning electron microscope (SEM) at room temperature and 300 °C shows that the material's local yield strength and ultimate tensile strength decreases with increased dose and elevated test temperature and provides further insights via localized strain mapping. Current and previous mechanical data was compared with calculated values using the dispersed barrier hardening model with inputs of dislocation loops, precipitates, and cavities from microstructural characterization.

36 MATERIALS SCIENCE↗

A digital CDS technique and its performance testing

Readout noise is a critical parameter for characterizing the performance of charge-coupled devices (CCDs), which can be greatly reduced by the correlated double sampling (CDS) circuit. However, a conventional CDS circuit inevitably introduces new noise since it consists of several active analog components such as operational amplifiers. This article proposes a digital CDS circuit technique, which transforms the pre-amplified CCD signal into a train of digital presentations by a high-speed data acquisition card directly without the noisy CDS circuit, then implements the digital CDS algorithm through a numerical method. A readout noise of 3.3 e - and an energy resolution of 121 eV@5.9 keV can be achieved via the digital CDS technique.

42 ENGINEERING↗

DISCOVERY OF A TIGHT CORRELATION FOR GAMMA-RAY BURST AFTERGLOWS WITH 'CANONICAL' LIGHT CURVES

Gamma-ray bursts (GRBs) observed up to redshifts z>8 are fascinating objects to study due to their still unexplained relativistic outburst mechanisms and their possible use to test cosmological models. Our analysis of 77 GRB afterglows with known redshifts revealed a physical subsample of long GRBs with the canonical plateau breaking to power-law light curves with a significant luminosity L*{sub X}-break time T*{sub a} correlation in the GRB rest frame. This subsample forms approximately the upper envelope of the studied distribution. We have also found a similar relation for a small sample of GRB afterglows that belong to the intermediate class between the short and the long ones. It proves that within the full sample of afterglows there exist physical subclasses revealed here by tight correlations of their afterglow properties. The afterglows with regular ('canonical') light curves obey not only the mentioned tight physical scaling, but-for a given T*{sub a}-the more regular progenitor explosions lead to preferentially brighter afterglows.

79 ASTRONOMY AND ASTROPHYSICS↗

Weak lensing probes of modified gravity

We study the effect of modifications to general relativity on large-scale weak lensing observables. In particular, we consider three modified gravity scenarios: f(R) gravity, the Dvali-Gabadadze-Porrati model, and tensor-vector-scalar theory. Weak lensing is sensitive to the growth of structure and the relation between matter and gravitational potentials, both of which will in general be affected by modified gravity. Restricting ourselves to linear scales, we compare the predictions for galaxy-shear and shear-shear correlations of each modified gravity cosmology to those of an effective dark energy cosmology with the same expansion history. In this way, the effects of modified gravity on the growth of perturbations are separated from the expansion history. We also propose a test which isolates the matter-potential relation from the growth factor and matter power spectrum. For all three modified gravity models, the predictions for galaxy and shear correlations will be discernible from those of dark energy with very high significance in future weak lensing surveys. Furthermore, each model predicts a measurably distinct scale dependence and redshift evolution of galaxy and shear correlations, which can be traced back to the physical foundations of each model. We show that the signal-to-noise for detecting signatures of modified gravity is much higher for weak lensing observables as compared to the integrated Sachs-Wolfe effect, measured via the galaxy-cosmic microwave background cross-correlation.

79 ASTRONOMY AND ASTROPHYSICS↗

Computational Intelligence Based Data Fusion Algorithm for Dynamic sEMG and Skeletal Muscle Force Modelling

In this work, an array of three surface Electrography (sEMG) sensors are used to acquired muscle extension and contraction signals for 18 healthy test subjects. The skeletal muscle force is estimated using the acquired sEMG signals and a Non-linear Wiener Hammerstein model, relating the two signals in a dynamic fashion. The model is obtained from using System Identification (SI) algorithm. The obtained force models for each sensor are fused using a proposed fuzzy logic concept with the intent to improve the force estimation accuracy and resilience to sensor failure or misalignment. For the fuzzy logic inference system, the sEMG entropy, the relative error, and the correlation of the force signals are considered for defining the membership functions. The proposed fusion algorithm yields an average of 92.49% correlation between the actual force and the overall estimated force output. In addition, the proposed fusionbased approach is implemented on a test platform. Experiments indicate an improvement in finger/hand force estimation.

42 ENGINEERING↗

Characterization of High Strain Rate Mechanical behavior of AZ31 magnesium alloy using 3D Digital Image Correlation

Characterization of the material mechanical behavior at sub-Hopkinson regime (0.1 to 1000 s{sup -1}) is very challenging due to instrumentation limitations and the complexity of data analysis involved in dynamic loading. In this study, AZ31 magnesium alloy sheet specimens are tested using a custom designed servo-hydraulic machine in tension at nominal strain rates up to 1000 s{sup -1}. In order to resolve strain measurement artifacts, the specimen displacement is measured using 3D Digital Image correlation instead from actuator motion. The total strain is measured up to {approx} 30%, which is far beyond the measurable range of electric resistance strain gages. Stresses are calculated based on the elastic strains in the tab of a standard dog-bone shaped specimen. Using this technique, the stresses measured for strain rates of 100 s{sup -1} and lower show little or no noise comparing to load cell signals. When the strain rates are higher than 250 s{sup -1}, the noises and oscillations in the stress measurements are significantly decreased from {approx} 250 to 50 MPa. Overall, it is found that there are no significant differences in the elongation, although the material exhibits slight work hardening when the strain rate is increased from 1 to 100 s{sup -1}.

36 MATERIALS SCIENCE↗