Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96

Microtomographic Measurements of Total Air‐Water Interfacial Areas for Soils

Abstract Synchrotron X‐ray microtomography (XMT) was used to measure total air‐water interfacial areas (A aw ) as a function of water saturation (S w ) for several soils that comprise a range of physical and geochemical properties. Measurements were also conducted for glass beads and quartz sands for comparison. Apparent near‐linearA aw ‐S w relationships are observed for the three sands and the three sandy soils. In contrast, the measured interfacial areas for two soils that contain greater proportions of silt and clay are strongly nonlinear functions of water saturation. The greater degree of nonlinearity observed for these two soils is due to their much greater particle‐size distributions (i.e., uniformity coefficients) and their concomitant greater range in pore sizes. Interfacial areas determined with the thermodynamic method were used to benchmark the XMT measurements. XMT‐measured interfacial areas compare well to the thermodynamic‐determined values for the sands and sandy soils. In contrast, the XMT‐measured interfacial areas for the two soils with larger particle‐size distributions are not fully congruent with the thermodynamic‐determined values. Both of these soils have large fractions of pore space comprising nominal pore diameters smaller than the resolution of the XMT imaging. These results suggest that air‐water interfacial area may not always be fully characterized by standard XMT for soils with large particle‐size distributions.

Environmental Sciences & Ecology↗

Perpendicular propagating electromagnetic envelope solitons in electron-positron-ion plasma

The nonlinear amplitude modulation of electromagnetic waves propagating perpendicular to the direction of ambient magnetic field in a uniform collisionless magnetized electron-positron-ion plasma is studied. The Krylov-Bogoliubov-Mitropolsky perturbation method is employed to derive nonlinear Schroedinger equation, which describes the amplitude dynamics of perturbed magnetic field. The modulation instability criterion reveals that the low frequency mode is always stable, whereas the high frequency mode becomes modulationally unstable for certain ranges of wave number and positron-to-electron density ratio. Furthermore, the positron-to-electron density ratio as well as the strength of ambient magnetic field is found to have significant effect on the solitary wave solutions of the nonlinear Schroedinger equation, namely, dark and bright envelope solitons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Revealing origin of quasi-one dimensional current transport in defect rich two dimensional materials

The presence of defects in graphene have for a long time been recognized as a bottleneck for its utilization in electronic and mechanical devices. We recently showed that micro four-point probes may be used to evaluate if a graphene film is truly 2D or if defects in proximity of the probe will lead to a non-uniform current flow characteristic of lower dimensionality. In this work, simulations based on a finite element method together with a Monte Carlo approach are used to establish the transition from 2D to quasi-1D current transport, when applying a micro four-point probe to measure on 2D conductors with an increasing amount of line-shaped defects. Clear 2D and 1D signatures are observed at low and high defect densities, respectively, and current density plots reveal the presence of current channels or branches in defect configurations yielding 1D current transport. A strong correlation is found between the density filling factor and the simulation yield, the fraction of cases with 1D transport and the mean sheet conductance. The upper transition limit is shown to agree with the percolation threshold for sticks. Finally, the conductance of a square sample evaluated with macroscopic edge contacts is compared to the micro four-point probe conductance measurements and we find that the micro four-point probe tends to measure a slightly higher conductance in samples containing defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Facile microwave-assisted synthesis of titanium dioxide decorated graphene nanocomposite for photodegradation of organic dyes

An efficient and facile method was adopted to prepare TiO{sub 2}-graphene (TG) nanocomposites with TiO{sub 2} nanoparticles uniformly distributed on graphene. By adjusting the amount of TiO{sub 2} precursor, both high and low dense TiO{sub 2} nanoparticles on graphene were effectively attained via electrostatic attraction between graphene oxide sheets and TiO{sub 2} nanoparticles. The prepared nanocomposites were characterized by various characterization techniques. The TG nanocomposite showed an excellent activity for the photodegradation of the organic dyes such as methylene blue (MB) and rose bengal (RB) under ultra violet (UV) light irradiation. The TG nanocomposite of TG 2.5 showed better photocatalytic performance than bare TiO{sub 2} nanoparticles and other composites. The enhanced activity of the composite material is attributed to the reduction in charge recombination and interaction of organic dyes with graphene. The decrease in charge recombination was evidenced from the photoluminescence (PL) spectra. The observed results suggest that the synthesized TG composites have a potential application to treat the industrial effluents, which contain organic dyes.

36 MATERIALS SCIENCE↗

Reduced graphene oxide filled poly(dimethyl siloxane) based transparent stretchable, and touch-responsive sensors

The ongoing revolution in touch panel technology and electronics demands the need for thin films, which are flexible, stretchable, conductive, and highly touch responsive. In this regard, conductive elastomer nanocomposites offer potential solutions for these stipulations; however, viability is limited to the poor dispersion of conductive nanomaterials such as graphene into the matrix. Here, we fabricated a reduced graphene oxide (rGO) and poly(dimethylsiloxane) (PDMS) elastomer based transparent and flexible conductive touch responsive film by dispersing rGO honeycombs uniformly into PDMS elastomer through an ionic liquid (IL) modification. Pursuing a simple, scalable, and safe method of solution casting, this provides a versatile and creative design of a transparent and stretchable rGO/IL-PDMS capacitive touch responsive, where rGO acts as a sensing element. This transparent film with ∼70% transmittance exhibits approximately a five times faster response in comparison to rGO/PDMS film, with negligible degradation over time. The performance of this touch screen film is expected to have applications in the emerging field of foldable electronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tri- and Quadri-metallic Ultrathin Nanowires Synthesized by One-step Phase-transfer Approach

We synthesized, at room temperature, noble multi-metallic (Pt-Pd-Rh, and Pt-Pd-Au-Rh) ultrathin nanowires using a one-step phase-transfer approach. These multi-metallic nanowires then were characterized by x-ray diffraction, transmission electron microscopy, and scanning transmission electron microscopy. The diameters of the nanowires range from 2 to 2.7 nm, and their lengths from tens to hundreds of nanometers. The multi-metallic nanowires were determined to be face-centered cubic structures. The compositions of the nanowires are quite uniform from wire to wire. Our results verify that the phase-transfer is a robust method for synthesizing various multi-metallic nanowires, which are expected to have potential applications in catalysis, magnetic storage, and bio-sensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Distributed Algorithm for Economic Dispatch Over Time-Varying Directed Networks With Delays

In power system operation, economic dispatch problem (EDP) is designed to minimize the total generation cost while meeting the demand and satisfying generator capacity limits. This paper proposes an algorithm based on the gradient-push method to solve the EDP in a distributed manner over communication networks potentially with time-varying topologies and communication delays. It has been shown that the proposed method is guaranteed to solve the EDP if the time-varying directed communication network is uniformly jointly strongly connected. Moreover, the proposed algorithm is also able to handle arbitrarily large but bounded time delays on communication links. Numerical simulations are used to illustrate and validate the proposed algorithm.

Yang, Tao↗

Positron emission mammography (PEM): Effect of activity concentration, object size, and object contrast on phantom lesion detection

Purpose: To characterize the relationship between lesion detection sensitivity and injected activity as a function of lesion size and contrast on the PEM (positron emission mammography) Flex Solo II scanner using phantom experiments. Methods: Phantom lesions (spheres 4, 8, 12, 16, and 20 mm diameter) were randomly located in uniform background. Sphere activity concentrations were 3 to 21 times the background activity concentration (BGc). BGc was a surrogate for injected activity; BGc ranged from 0.44-4.1 kBq/mL, corresponding to 46-400 MBq injections. Seven radiologists read 108 images containing zero, one, or two spheres. Readers used a 5-point confidence scale to score the presence of spheres. Results: Sensitivity was 100% for lesions {>=}12 mm under all conditions except for one 12 mm sphere with the lowest contrast and lowest BGc (60% sensitivity). Sensitivity was 100% for 8 mm spheres when either contrast or BGc was high, and 100% for 4 mm spheres only when both contrast and BGc were highest. Sphere contrast recovery coefficients (CRC) were 49%, 34%, 26%, 14%, and 2.8% for the largest to smallest spheres. Cumulative specificity was 98%. Conclusions: Phantom lesion detection sensitivity depends more on sphere size and contrast than on BGc. Detection sensitivity remained {>=}90% for injected activities as low as 100 MBq, for lesions {>=}8 mm. Low CRC in 4 mm objects results in moderate detection sensitivity even for 400 MBq injected activity, making it impractical to optimize injected activity for such lesions. Low CRC indicates that when lesions <8 mm are observed on PEM images they are highly tracer avid with greater potential of clinical significance. High specificity (98%) suggests that image statistical noise does not lead to false positive findings. These results apply to the 85 mm thick object used to obtain them; lesion detectability should be better (worse) for thinner (thicker) objects based on the reduced (increased) influence of photon attenuation.

60 APPLIED LIFE SCIENCES↗

SU-E-I-91: Reproducibility in Prescribed Dose in AEC CT Scans Due to Table Height, Patient Size, and Localizer Acquisition Order

Purpose: In CT scanners, the automatic exposure control (AEC) tube current prescription depends on the acquired prescan localizer image(s). The purpose of this study was to quantify the effect that table height, patient size, and localizer acquisition order may have on the reproducibility in prescribed dose. Methods: Three phantoms were used for this study: the Mercury Phantom (comprises three tapered and four uniform regions of polyethylene 16, 23, 30, and 37 cm in diameter), acrylic sheets, and an adult anthropomorphic phantom. Phantoms were positioned per clinical protocol by our chief CT technologist or broader symmetry. Using a GE Discovery CT750HD scanner, a lateral (LAT) and posterior-anterior (PA) localizer was acquired for each phantom at different table heights. AEC scan acquisitions were prescribed for each combination of phantom, localizer orientation, and table height; the displayed volume CTDI was recorded for each. Results were analyzed versus table height. Results: For the two largest Mercury Phantom section scans based on the PA localizer, the percent change in volume CTDI from ideal were at least 20% lower and 35% greater for table heights 4 cm above and 4 cm below proper centering, respectively. For scans based on the LAT localizer, the percent change in volume CTDI from ideal were no greater than 12% different for 4 cm differences in table height. The properly centered PA and LAT localizer-based volume CTDI values were within 13% of each other. Conclusion: Since uncertainty in vertical patient positioning is inherently greater than lateral positioning and because the variability in dose exceeds any dose penalties incurred, the LAT localizer should be used to precisely and reproducibly deliver the intended amount of radiation prescribed by CT protocols. CT protocols can be adjusted to minimize the expected change in average patient dose.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-11: Activity Distributions of Positron-Emitting-Isotopes Activated by Modulated Spot-Scanning Particle Beams

Purpose: To present the characteristics of positron-emitting-isotope (PEI) activity distributions on homogeneous and CIRS thorax phantoms irradiated by modulated spot-scanning carbon-ions and protons in Siemens IONTRIS system. Methods and Materials: Cylindrical homogeneous wax was irradiated by carbon-ions and protons of 10cm uniform square field with single-energy-layer ranges of 7cm, 16cm and 29cm. Images of PEI distributions were acquired over a period of 30 minutes at 10 minutes after each irradiation. Optimized uniform biological-equivalent doses of carbon-ions over a 5.0cm spherical target was delivered to CIRS phantom. Doses with range shifts in depths from 1mm to 6mm were also calculated and delivered to evaluate the accuracy of measuring activated PEI distributions. Results: Activated PEI distribution on homogeneous phantoms showed sharper peak near distal edge with flatter distribution toward proximal depth by carbon-ions than by protons. For depths near at Bragg-peak, penetration-depth spreading for energies from 10MeV/u to 60 MeV/u are from 0.4mm to 10.3mm, and 1.2mm to 30.4mm for projectile-fragments by carbon-ions and target-fragments by protons, respectively. For depths proximal to Bragg-peak, target-fragments for both carbon-ions and protons had minimal energy dependence in depth. For complex dose distributions delivered to CIRS thorax phantom, similar PEI peak-like distributions were still observed for carbon-ions. And, the changes at locations and edges of measured PEI peak were correlated within 0.5mm of shifted ranges. Mean activities over 5.0cm spherical target were similar for CISR phantom irradiated by doses with various range shifts. Conclusions: Peak-like PEI distributions by carbon-ions with good correlation to distal edges in both homogeneous and CIRS thorax phantoms present the potential for the in-vivo range verification while additional efforts is needed for protons. Due to flat distributions for depths at 6mm proximal to distal edges, mean activity at target might be used for in-vivo dose verification of target.

60 APPLIED LIFE SCIENCES↗

Daily QA of linear accelerators using only EPID and OBI

Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D ion-chamber array agree within ±0.5% and ±1.2% for crossline and inline profiles, respectively. MLC position errors of 0.5 mm can be detected using a picket fence test. The field size and phantom positioning accuracy can be determined within 0.5 mm. The entire daily QA process takes ∼15 min to perform tests for 5 photon beams, MLC tests, and imaging checks. Conclusions: The exclusive use of EPID-based QA tools, including a QA phantom and simultaneous analysis software tools, has been demonstrated as a viable, efficient, and comprehensive process for daily evaluation of LINAC performance.

60 APPLIED LIFE SCIENCES↗

Methods for the chemical synthesis of carbon nanotubes: an approach based on hemispherical polyarene templates

Abstract Hemispherical polyarenes represent attractive templates from which carbon nanotubes of the same diameter and rim structure (chirality) might be grown by repetitive annulation reactions. The resulting single-index ( n,m ) nanotubes would have one end open and the other end capped by the original template. Efforts in the author’s laboratory to synthesize (5,5) and (6,6) nanotube end-caps are described. Nitroethylene is shown to serve well as a “masked acetylene” for the conversion of polyarene bay regions into new unsubstituted benzene rings by a Diels-Alder cycloaddition/aromatization process. Benzyne reacts similarly, both in solution and in the gas phase. These annulation reactions are proposed as methods for elongating large-diameter templates that have bay regions on their rims into structurally uniform, single-walled carbon nanotubes. Unfortunately, the bay regions on the strongly curved rim of the small-diameter (5,5) nanotube end-cap 3 resist Diels-Alder cycloadditions with both nitroethylene and benzyne. Pentabenzocorannulene ( 14 ) is proposed as a promising candidate for surface-catalyzed cyclodehydrogenation to a surface-bound hemispherical polyarene that could serve as a template for synthesis of pure (5,5) carbon nanotubes.

Chemistry↗

Compaction Behavior of Surrogate Degraded Emplaced WIPP Waste

The present study results are focused on laboratory testing of surrogate waste materials. The surrogate wastes correspond to a conservative estimate of degraded Waste Isolation Pilot Plant (WIPP) containers and TRU waste materials at the end of the 10,000 year regulatory period. Testing consists of hydrostatic, triaxial, and uniaxial strain tests performed on surrogate waste recipes that were previously developed by Hansen et al. (1997). These recipes can be divided into materials that simulate 50% and 100% degraded waste by weight. The percent degradation indicates the anticipated amount of iron corrosion, as well as the decomposition of cellulosics, plastics, and rubbers (CPR). Axial, lateral, and volumetric strain and axial, lateral, and pore stress measurements were made. Two unique testing techniques were developed during the course of the experimental program. The first involves the use of dilatometry to measure sample volumetric strain under a hydrostatic condition. Bulk moduli of the samples measured using this technique were consistent with those measured using more conventional methods. The second technique involved performing triaxial tests under lateral strain control. By limiting the lateral strain to zero by controlling the applied confining pressure while loading the specimen axially in compression, one can maintain a right-circular cylindrical geometry even under large deformations. This technique is preferred over standard triaxial testing methods which result in inhomogeneous deformation or “barreling”. Manifestations of the inhomogeneous deformation included non-uniform stress states, as well as unrealistic Poisson’s ratios (> 0.5) or those that vary significantly along the length of the specimen. Zero lateral strain controlled tests yield a more uniform stress state, and admissible and uniform values of Poisson’s ratio.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Atmospheric effects on remote sensing of non-uniform temperature sources

The effects are considered of an absorbing, emitting, and scattering atmosphere upon the remote sensing of surface areas having non-uniform intensity. These atmospheric effects may be significant in determination, by remote sensing, of non-uniform surface temperature distributions, and the results of the investigation are applicable in such cases. Analytical methods and a digital computational program are presented, expressing the results in terms of contrast and contrast transmittance between two adjacent emitting areas having unequal intensities, in the presence of a additional disturbing emitters. In the computational procedure, emitting areas are replaced by point-source emitters, each assigned and effective intensity based upon the intensity of the area it replaces. Absorbing, emitting, and scattering behavior of the atmosphere may be specified in the computational procedure either by means of analytical atmospheric models or by means of calibrating ground level emitters.

Mcneill, W. A.↗

Theoretical investigation of nonlinear three-dimensional instabilities in liquid rockets with real nozzles

An approximate analytical technique has been developed for the solution of nonlinear three-dimensional, transverse and axial combustion-instability problems that are frequently observed in liquid-propellant rocket motors. This theory is an extension and generalization of previous analyses, which could analyze either transverse or axial instabilities in liquid combustors with quasi-steady nozzles, to the practical situations of three-dimensional instabilities in combustors with conventional DeLaval nozzles. Unlike the quasi-steady nozzle, the presence of a conventional nozzle imposes restrictions upon the behavior of both the amplitudes and phases of the oscillations at the nozzle entrance plane. The applicability of the solution technique, which is based on the Galerkin method, is demonstrated by analyzing the nonlinear stability of a cylindrical liquid-rocket combustor with uniform injection of propellants at one end and a conventional nozzle at the other end. Crocco's pressure-sensitive time-lag model is used to describe the unsteady combustion process.

Powell, E. A.↗

A review and assessment of the stress-intensity factors for surface cracks

The stress-intensity factor solutions proposed for a surface crack in a finite plate subjected to uniform tension are reviewed. Fourteen different solutions obtained over the past 16 years using approximate analytical methods, experimental methods, and engineering estimates are compared. The accuracy of the various solutions is assessed by correlating fracture data on surface-cracked tension specimens made of a brittle epoxy material. Fracture of the epoxy material was characterized by a constant value of stress-intensity factor as failure. Thus, the correctness of various solutions is judged by the variations in the stress-intensity factors at failure. The solutions were ranked in order of minimum standard deviation. The highest ranking solutions correlated 95% of data analyzed within + or - 10% whereas the lowest ranking solutions correlated 95% of data analyzed within + or - 20%. Some solutions could be applied to all data considered, whereas others were limited with respect to crack shapes and crack sizes that could be analyzed.

Newman, J. C., Jr.↗

Synthetic aperture radar range - Azimuth ambiguity design and constraints

Problems concerning the design of a system for mapping a planetary surface with a synthetic aperture radar (SAR) are considered. Given an ambiguity level, resolution, and swath width, the problems are related to the determination of optimum antenna apertures and the most suitable pulse repetition frequency (PRF). From the set of normalized azimuth ambiguity ratio curves, the designer can arrive at the azimuth antenna length, and from the sets of normalized range ambiguity ratio curves, he can arrive at the range aperture length or pulse repetition frequency. A procedure based on this design method is shown in an example. The normalized curves provide results for a SAR using a uniformly or cosine weighted rectangular antenna aperture.

Mehlis, J. G.↗

Vibrations of blades with variable thickness and curvature by shell theory

A procedure for analyzing the vibrations of rotating turbomachinery blades has been previously developed. This procedure is based upon shallow shell theory, and utilizes the Ritz method to determine frequencies and mode shapes. However, it has been limited heretofore to blades of uniform thickness, uniform curvature, and/or twist and rectangular planform. The present work shows how the procedure may be generalized to eliminate the aforementioned restrictions. Nonrectangular planforms are dealt with by a suitable coordinate transformation. This, as well as variable thickness, curvature and twist, require using numerical integration. The procedure is demonstrated on four examples of cantilevered blades for which theoretical and experimental data have been previously published: (1) flat plate with spanwise taper, (2) flat plate with chordwise taper, (3) twisted plate with chordwise taper, and (4) cylindrical shell with chordwise taper.

Lee, J. K.↗