At least 1,747 records · Page 97

Analytical solutions for transient and steady state beam loading in arbitrary traveling wave accelerating structures

Analytical solutions are derived for both transient and steady state gradient distributions in the traveling wave (TW) accelerating structures with arbitrary variation of parameters over the structure length. The results of the unloaded and beam loaded cases are presented. Finally, the exact analytical shape of the rf pulse waveform was found in order to apply the transient beam loading compensation scheme during the structure filling time. The obtained theoretical formulas were cross-checked by direct numerical simulations on the CLIC main linac accelerating structure and demonstrated a good agreement. The proposed methods provide a fast and reliable tool for the initial stage of the TW structure analysis.

43 PARTICLE ACCELERATORS↗

SU-F-T-66: Characteristics of Electron Beams From Varian Trubeam

Purpose: The purpose of this study was to compare the electron beam data between Truebeam and 2300ix Varian accelerators for percent depth dose for broad beam and small circular cutouts, cone factors, head scatter factor as a function of cone size and SSD, phantom scatter factor, blocking factor, distance factor and virtual source position. Methods: Measurements were performed for Truebeam and 2300ix Varian accelerators. The main energies used were: 6, 9, 12, 16 and 20 MeV. PDD was measured at SSD = 100 cm for open beam and small circular cutouts (r = 0.5, 1.0, 1.5, 2.0, 3.0, 4.0 and 6.6cm) for different energies. Measurements to determine the head scatter factor (H) were done as a function of radius for six representative energies and five cone sizes (6, 10, 15, 20 and 25cm2). The phantom scatter factor (PSF) is defined as the ratio of blocking factor in water at reference depth and head scatter factor in air. PSF was measured as a function of radius and electron energy. Distance factor was measured for all energies and cones for three SSD’s (100, 110 and 120cm). Results: The percent depth dose (PDD) was measured for small cutouts of radius r = 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 and 5.6cm. Blocking factor (BF) was measured for Truebeam and 2300ix accelerators, for different circular cutouts and energies for a 10×10 cone. Cone factors were compared between the two accelerators for different energies and applicator sizes. Conclusion: Cone factors measured for the two accelerator types differ by up to 5% for the largest applicator size. Blocking factors differs by up to 3%, with the largest variation for the smallest field size (0.5cm). Distance factor for different SSD’s differ by up to 4.5%.

43 PARTICLE ACCELERATORS↗

Nonlinear Dynamics and Phase Space Manipulations of High-Brightness Beams

The project consisted of two main tasks. Each task had several specific aims. The three main objectives of Task 1 were: 1. Investigation of the flat beam technique to produce high transverse emittance ratio longitudinally-compressed bunches, 2. Exploration of a new chicane-like transverse-to-longitudinal phase space exchanger for precise pulse shaping and emittance exchange, 3. Applications of flat-beam with shaped current profile(s) to dielectric wakefield acceleration in an asymmetric waveguide. The outcome of our research was to performed details simulations of flat-beam generation and compression. Some preliminary experiment on flat-beam generation and compression were conducted at the FAST-IOTA injector in parallel to commissioning activities. Likewise, the longitudinal phase-space transformation was not fully explored; we participated in experiments conducted at the Argonne Wakefield Accelerator and especially introduced a simple transverse-shaping technique.

43 PARTICLE ACCELERATORS↗

Curved Mesh Correction And Adaptation Tool to Improve COMPASS Electromagnetic Analyses

SLAC performs large-scale simulations for the next-generation accelerator design using higher-order finite elements. This method requires using valid curved meshes and adaptive mesh refinement in complex 3D curved domains to achieve its fast rate of convergence. ITAPS has developed a procedure to address those mesh requirements to enable petascale electromagnetic accelerator simulations by SLAC. The results demonstrate that those correct valid curvilinear meshes can not only make the simulation more reliable but also improve computational efficiency up to 30%. This paper presents a procedure to track moving adaptive mesh refinement in curved domains. The procedure is capable of generating suitable curvilinear meshes to enable large-scale accelerator simulations. The procedure can generate valid curved meshes with substantially fewer elements to improve the computational efficiency and reliability of the COMPASS electromagnetic analyses. Future work will focus on the scalable parallelization of all steps for petascale simulations.

43 PARTICLE ACCELERATORS↗

Generation of double pulses at the Shanghai soft X-ray free electron laser facility

In this paper, we present the promise of a new method generating double electron pulses with the picosecond-scale pulse length and the tunable interpulse spacing at several picoseconds, which has been witnessed an impressive potential of application in pump-probe techniques, two-color X-ray free electron laser (FEL), high-gradient witness bunch acceleration in a plasma, etc. Three-dimensional simulations are carried out to analyze the dynamic of the electron beam in the linear accelerator. Some comparisons have been made between the new method and the existing ways as well.

43 PARTICLE ACCELERATORS↗

Quantitative phosphoproteomics reveals GTBP-1 regulating C.elegans lifespan at different environmental temperatures

Highlights: • Comprehensive quantitative phosphoproteomics study of C.elegans during aging under different temperatures. • Phosphoproteomics analysis identified important proteins and signaling pathways. • The kinases CK2, MAPK and CAMK2 might play important roles in aging. • Functional experiments confirm that GTBP-1 could regulate C.elegans lifespan. • An important resource for future studies of protein phosphorylation in C.elegans. Temperature is one of the primary environmental factors that affect aging, in which protein phosphorylation is an important regulator. Currently, the understanding of phosphorylation events in regulatory networks during aging has remained rather limited. Herein, the phosphoproteomes of C.elegans of different age groups cultured at 20 °C (natural aging) and 25 °C (accelerated aging) were analyzed. Through using the iTRAQ-labeled phosphoproteomics method, 2375 phosphoproteins and 9063 phosphosites were identified. Volcano plots illustrated that 208 proteins during natural aging and 130 proteins during accelerated aging, were significantly changed. Gene ontology and pathway analysis revealed that these proteins were mainly involved in translation, development, metabolisms, and animal behavior processes. Moreover, our results uncovered those kinases CK2, MAPK and CAMK2 might play important roles in aging regulation. Functional experiments confirm that the candidated phosphoprotein GTBP-1 could regulate C.elegans lifespan at 20 °C or 25 °C and is more resistant to heat and oxidative stresses. In summary, our results provided an important resource for future studies of protein phosphorylation in worms. Data are available via ProteomeXchange with identifier PXD009661.

60 APPLIED LIFE SCIENCES↗

Exact solution of multi-bunch instabilities for ultra-relativistic constant energy bunches in particle accelerators

In particle accelerators the multi-bunch beams of charged particles excite electromagnetic wakefields in the accelerating cavities and other beam-line components. These wakefields may cause instability in the longitudinal and transverse motion of these bunches leading to the beam loss. Thus, the analysis of such multi-bunch effects is critical in any accelerator design. Here in this paper, we present a new analytical method to exactly describe the multi-bunch transverse instabilities for ultra-relativistic electron bunches coasting at a constant energy through a uniform beam-focusing system. We discuss two cases: same bunch energy for all bunches and different energy from bunch to bunch. For the first case the solution is based on a special class of polynomials, while for the second case the solution is a finite sum of sinusoidal functions. We demonstrate the use of this approach with examples and compare the results of a numerical differential equation solver against our rigorous results. Our method could also be applied to the analysis of beam breakup within a single bunch. This approach can be extended beyond accelerator physics to study other many-body systems where an $n\mathrm{th}$ body is affected by only the preceding $n-1$ bodies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Local Tumor Control, Visual Acuity, and Survival After Hypofractionated Stereotactic Photon Radiotherapy of Choroidal Melanoma in 212 Patients Treated Between 1997 and 2007

Purpose: To evaluate long-term local tumor control, visual acuity, and survival after hypofractionated linear accelerator-based stereotactic photon radiotherapy in patients with choroidal melanoma. Methods and Materials: Between 1997 and 2007, 212 patients with choroidal melanoma unsuitable for ruthenium-106 brachytherapy or local resection were treated stereotactically at a linear accelerator with 6-MV photon beams at the Medical University of Vienna in five fractions over 7 days. Twenty-four patients received a total dose of 70 Gy (five fractions of 14 Gy), 158 a total dose of 60 Gy (five fractions of 12 Gy) and 30 patients a total dose of 50 Gy (five fractions of 10 Gy) applied on the 80% isodose. Ophthalmologic examinations were performed at baseline and every 3 months in the first 2 years, every 6 months until 5 years, and once a year thereafter until 10 years after radiotherapy. Assessment of visual acuity, routine ophthalmologic examinations, and measurement of tumor base dimension and height using standardized A-scan and B-scan echography were done at each visit. Funduscopy and fluorescein angiography were done when necessary to document tumor response. Results: Median tumor height and volume decreased from 4.8 mm and 270.7 mm{sup 3} at baseline to 2.6 mm and 86.6 mm{sup 3} at the last individual follow-up, respectively (p < 0.001, p < 0.001). Median visual acuity decreased from 0.55 at baseline to hand motion at the last individual follow-up (p < 0.001). Local tumor control was 95.9% after 5 years and 92.6% after 10 years. Thirty-two patients developed metastatic disease, and 22 of these patients died during the follow-up period. Conclusion: Hypofractionated stereotactic photon radiotherapy with 70 to 50 Gy delivered in five fractions in 7 days is sufficient to achieve excellent local tumor control in patients with malignant melanoma of the choroid. Disease outcome and vision are comparable to those achieved with proton beam radiotherapy. Decreasing the total dose below 60 Gy seems to be possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-FG-202-03: Efficient Data Collection of Continuous 2D and Discrete Relative Dosimetric Data for Annual LINAC QA Using TrueBeam Developer Mode and a 1D Scanning Tank

Purpose: To develop a method to exploit real-time dynamic machine and couch parameter control during linear accelerator (LINAC) beam delivery to facilitate efficient performance of TG-142 suggested, Annual LINAC QA tests. Methods: Varian’s TrueBeam Developer Mode (Varian Medical Systems, Palo Alto, CA) facilitates control of Varian’s TrueBeam LINAC via instructions provided in Extensible Markup Language (XML) files. This allows machine and couch parameters to be varied dynamically, in real-time, during beam delivery. Custom XML files were created to allow for the collection of (1) continuous Tissue Maximum Ratios (TMRs), (2) beam profiles, and (3) continuous output factors using a 1D-scanning tank. TMRs were acquired by orienting an ionization chamber (IC) at isocenter (depth=25cm) and synchronizing a depth scan towards the water surface while lowering the couch at 1mm/s. For beam profiles, the couch was driven laterally and longitudinally while logging IC electrometer readings. Output factors (OFs) where collected by continually varying field sizes (4×4 to 30×30-cm{sup 2}) at a constant speed of 6.66 mm/s. To validate measurements, comparisons were made to data collected using traditional methods (e.g. 1D or 3D tank). Results: All data collecting using the proposed methods agreed with traditionally collected data (TMRs within 1%, OFs within 0.5% and beam profile agreement within 1% / 1mm) while taking less time to collect (factor of approximately 1/10) and with a finer sample resolution. Conclusion: TrueBeam developer mode facilitates collection of continuous data with the same accuracy as traditionally collected data with a finer resolution in less time. Results demonstrate an order of magnitude increase in sampled resolution and an order of magnitude reduction in collection time compared to traditional acquisition methods (e.g. 3D scanning tank). We are currently extending this approach to perform other TG-142 tasks.

61 RADIATION PROTECTION AND DOSIMETRY↗

Laser Wakefield Acceleration: Structural and Dynamic Studies. Final Technical Report ER40954

Particle accelerators enable scientists to study the fundamental structure of the universe, but have become the largest and most expensive of scientific instruments. In this project, we advanced the science and technology of laser-plasma accelerators, which are thousands of times smaller and less expensive than their conventional counterparts. In a laser-plasma accelerator, a powerful laser pulse exerts light pressure on an ionized gas, or plasma, thereby driving an electron density wave, which resembles the wake behind a boat. Electrostatic fields within this plasma wake reach tens of billions of volts per meter, fields far stronger than ordinary non-plasma matter (such as the matter that a conventional accelerator is made of) can withstand. Under the right conditions, stray electrons from the surrounding plasma become trapped within these “wake-fields”, surf them, and acquire energy much faster than is possible in a conventional accelerator. Laser-plasma accelerators thus might herald a new generation of compact, low-cost accelerators for future particle physics, x-ray and medical research. In this project, we made two major advances in the science of laser-plasma accelerators. The first of these was to accelerate electrons beyond 1 gigaelectronvolt (1 GeV) for the first time. In experimental results reported in Nature Communications in 2013, about 1 billion electrons were captured from a tenuous plasma (about 1/100 of atmosphere density) and accelerated to 2 GeV within about one inch, while maintaining less than 5% energy spread, and spreading out less than ½ milliradian (i.e. ½ millimeter per meter of travel). Low energy spread and high beam collimation are important for applications of accelerators as coherent x-ray sources or particle colliders. This advance was made possible by exploiting unique properties of the Texas Petawatt Laser, a powerful laser at the University of Texas at Austin that produces pulses of 150 femtoseconds (1 femtosecond is 10-15 seconds) in duration and 150 Joules in energy (equivalent to the muzzle energy of a small pistol bullet). This duration was well matched to the natural electron density oscillation period of plasma of 1/100 atmospheric density, enabling efficient excitation of a plasma wake, while this energy was sufficient to drive a high-amplitude wake of the right shape to produce an energetic, collimated electron beam. Continuing research is aimed at increasing electron energy even further, increasing the number of electrons captured and accelerated, and developing applications of the compact, multi-GeV accelerator as a coherent, hard x-ray source for materials science, biomedical imaging and homeland security applications. The second major advance under this project was to develop new methods of visualizing the laser-driven plasma wake structures that underlie laser-plasma accelerators. Visualizing these structures is essential to understanding, optimizing and scaling laser-plasma accelerators. Yet prior to work under this project, computer simulations based on estimated initial conditions were the sole source of detailed knowledge of the complex, evolving internal structure of laser-driven plasma wakes. In this project we developed and demonstrated a suite of optical visualization methods based on well-known methods such as holography, streak cameras, and coherence tomography, but adapted to the ultrafast, light-speed, microscopic world of laser-driven plasma wakes. Our methods output images of laser-driven plasma structures in a single laser shot. We first reported snapshots of low-amplitude laser wakes in Nature Physics in 2006. We subsequently reported images of high-amplitude laser-driven plasma “bubbles”, which are important for producing electron beams with low energy spread, in Physical Review Letters in 2010. More recently, we have figured out how to image laser-driven structures that change shape while propagating in a single laser shot. The latter techniques, which use the methods of computerized tomography, were demonstrated on test objects – e.g. laser-driven filaments in air and glass – and reported in Optics Letters in 2013 and Nature Communications in 2014. Their output is a multi-frame movie rather than a snapshot. Continuing research is aimed at applying these tomographic methods directly to evolving laser-driven plasma accelerator structures in our laboratory, then, once perfected, to exporting them to plasma-based accelerator laboratories around the world as standard in-line metrology instruments.

43 PARTICLE ACCELERATORS↗

Simulation of large x-ray fields using independently measured source and geometry details

Purpose: Obtain an accurate simulation of the dose from the 6 and 18 MV x-ray beams from a Siemens Oncor linear accelerator by comparing simulation to measurement. Constrain the simulation by independently determining parameters of the treatment head and incident beam, in particular, the energy and spot size. Methods: Measurements were done with the treatment head in three different configurations: (1) The clinical configuration, (2) the flattening filter removed, and (3) the target and flattening filter removed. Parameters of the incident beam and treatment head were measured directly. Incident beam energy and spectral width were determined from the percent-depth ionization of the raw beam (as described previously), spot size was determined using a spot camera, and the densities of the flattening filters were determined by weighing them. Simulations were done with EGSnrc/BEAMnrc code. An asymmetric simulation was used, including offsets of the spot, primary collimator, and flattening filter from the collimator rotation axis. Results: Agreement between measurement and simulation was obtained to the least restrictive of 1% or 1 mm at 6 MV, both with and without the flattening filter in place, except for the buildup region. At 18 MV, the agreement was 1.5%/1.5 mm with the flattening filter in place and 1%/1 mm with it removed, except for in the buildup region. In the buildup region, the discrepancy was 2%/2 mm at 18 MV and 1.5%/1.5 mm at 6 MV with the flattening filter either removed or in place. The methodology for measuring the source and geometry parameters for the treatment head simulation is described. Except to determine the density of the flattening filter, no physical modification of the treatment head is necessary to obtain those parameters. In particular, the flattening filter does not need to be removed as was done in this work. Conclusions: Good agreement between measured and simulated dose distributions was obtained, even in the buildup region. The simulation was tightly constrained by independent measurements of parameters of the incident beam and treatment head. The method of obtaining the input parameters is described, and can be carried out on a clinical linear accelerator.

61 RADIATION PROTECTION AND DOSIMETRY↗

NA48/2 Results and NA62 Perspectives

Recent results on rare and radiative {Kappa}{sup {+-}} decays from the NA48/2 experiment are reported. Among many rare decay modes, the analysis of {Kappa}{sup {+-}}{yields}{pi}{sup +}{pi}{sup -}e{sup {+-}}{nu} ({Kappa}{sub e4}) decays allows a quasi model-independent approach to the study of low energy {pi}{pi} scattering. With more than 1 million {Kappa}{sub e4} decays the form factors and their energy dependence are measured with an improved precision. In the channel {Kappa}{sup {+-}}{yields}{pi}{sup {+-}}{pi}{sup 0}{gamma} more than 1 million decays were reconstructed, leading to the first measurement of the interference between direct photon emission and inner bremsstrahlung contributions as well as new limits on CP violation. For {Kappa}{sup {+-}}{yields}{pi}{sup {+-}}{gamma}{gamma}, a precise measurement of the branching fraction was performed, based on more than 1000 events. In addition the perspectives of NA62 to measure the branching ratio of the very rare kaon decay {Kappa}{sup +}{yields}{pi}{sup +}{nu}{nu} at the CERN SPS are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operator-level quantum acceleration of non-logconcave sampling

Sampling from probability distributions of the form 𝝈 ∝ e −𝜷V , where V is a continuous potential, is a fundamental task across physics, chemistry, biology, computer science, and statistics. However, when V is nonconvex, the resulting distribution becomes non-logconcave, and classical methods such as Langevin dynamics often exhibit poor performance. We introduce a quantum algorithm that provably accelerates a broad class of continuous-time sampling dynamics. For Langevin dynamics, our method encodes the target Gibbs measure into the amplitudes of aquantum state, identified as the kernel of a block matrix derived from a factorization of the Witten Laplacian operator. This connection enables Gibbs sampling via singular value thresholding and yields up to a quartic quantum speedup over best-knownclassical Langevin-based methods in the non-logconcave setting. Building on this framework, we further develop the first quantum algorithm that accelerates replica exchange Langevin diffusion, a widely used method for sampling from complex, rugged energy landscapes.

97 MATHEMATICS AND COMPUTING↗

New Parameter in the Description of Solar Cosmic Ray Events—Energy of Balance between Solar and Galactic Protons

Solar proton events possess a wide variety of features that reflect the conditions of solar proton acceleration and propagation. Relevant investigations rely on statistical methods that make it possible to classify events with the aim of obtaining deeper insight into physical processes leading to the generation of solar cosmic rays. In classifying events in power, the intensity of particles with energy above 10MeV at the maximum of the event time profile or the fluence of particles throughout the event time is usually used. A new parameter, E{sub qm}, that characterizes the proton event power and which is some kind of approximation of the maximum energy of accelerated particles is analyzed in the present study. Correlations of E{sub qm} with properties of x-ray flares on the Sun and with the velocity of coronal mass ejections are examined.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-BRB-07: Alanine and Monte Carlo Determined Beam Quality Corrections for Nonstandard Fields of the Varian TrueBeam Accelerator

Purpose: To determine beam quality correction factors for flattened and unflattened beams of the Varian TrueBeam™ accelerator using alanine measurements and Monte Carlo calculations. Methods: Measurements were performed using L-α-alanine pellets encased in Virtual Water™ paddles. These were irradiated in liquid water using various field sizes of the 6MV and 10MV beam energies of the TrueBeam™, with both flattening-filter-free (FFF) and flattened beam modes. Measurements were also performed in a 10×10 cm{sup 2} {sup 60}Co field. Pellets were read out by the National Physical Laboratory (NPL, Teddington, UK) using electron paramagnetic resonance (EPR) spectrometry, and results were corrected for energy dependence using graphite calorimetry. Beam quality correction factors (k{sub Q}, k{sub Q}msr,Q, and k{sub Q}clin,Q{sub msr}) were determined for three ionization chambers: an Exradin A12 Farmer-type chamber, an Exradin A1SL scanning chamber, and an Exradin A26 microchamber. All chambers were modeled in the egs-chamber user code of EGSnrc. Sources were created using Varian-supplied IAEA-compliant phase spaces and the BEAMnrc user code, and were validated by comparing measured and simulated dose profiles. Results: Measured and calculated k{sub Q} values agreed within uncertainties, showing the chamber models to be reliable. A comparison of measured and calculated k{sub Q}msr,Q results with TG-51-based values showed that TG-51 adequately accounts for variations in beam quality between flattened and unflattened 10×10 cm{sup 2} fields. Small field corrections, k{sub Q}clin,Q{sub msr}, were determined to be up to 5%, referenced to a 10×10 cm{sup 2} field of the same energy and mode. Conclusion: Beam quality corrections were determined for several beam energies of the TrueBeam™ accelerator using Monte Carlo calculations and were validated using measurements with alanine. Values of k{sub Q} determined using TG-51 were found to be adequate for FFF reference fields. However, small field corrections are necessary for both flattened and unflattened beams to ensure greater treatment planning accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of linear multifrequency-grey acceleration to preconditioned Krylov iterations for thermal radiation transport

The thermal radiative transfer (TRT) equations comprise a radiation equation coupled to the material internal energy equation. Linearization of these equations produces effective, thermally-redistributed scattering through absorption-reemission. In this paper, we investigate the effectiveness and efficiency of Linear-Multi-Frequency-Grey (LMFG) acceleration that has been reformulated for use as a preconditioner to Krylov iterative solution methods. We introduce two general frameworks, the scalar flux formulation (SFF) and the absorption rate formulation (ARF), and investigate their iterative properties in the absence and presence of true scattering. SFF has a group-dependent state size but may be formulated without inner iterations in the presence of scattering, while ARF has a group-independent state size but requires inner iterations when scattering is present. We compare and evaluate the computational cost and efficiency of LMFG applied to these two formulations using a direct solver for the preconditioners. Finally, this work is novel because the use of LMFG for the radiation transport equation, in conjunction with Krylov methods, involves special considerations not required for radiation diffusion.