Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Renewable Energy and Efficiency Technologies in Scenarios of U.S. Decarbonization in Two Types of Models: Comparison of GCAM Modeling and Sector-Specific Modeling

Energy system projections from quantitative models inform actions ranging from short-term and local decisions, such as those about technology and infrastructure deployment, and global and long-term negotiations and targets. Computational limits require model designers to balance coverage and resolution (i.e., breadth versus depth). Some models, such as the Global Change Analysis Model (GCAM), represent all energy sources and uses with less resolution than models that focus on a single sector's energy use. GCAM balances global supply and demand of all energy carriers projecting prices using internal calculations for energy sources and costs of greenhouse gas mitigation while capturing interlinkages between the energy system, water, agriculture and land use, the economy, and the climate. This globally comprehensive model was used to frame the Long-Term Strategy of the United States: Pathways to Net-Zero Greenhouse Gas Emissions by 2050, which the White House released in 2021 and has been used to inform national and global economy-wide climate change mitigation discussions and strategy development for decades. Unlike GCAM, sectoral models focus on a portion of the energy sector and with greater detail and resolution. The Regional Energy Deployment System (ReEDS) electricity-sector model, for example, projects electricity system capacity expansion and operation with high-fidelity representation of emerging technologies for deep decarbonization, such as variable renewable energy and energy storage, and integration of these technologies into the electric grid. The Transportation Energy and Mobility Pathway Options (TEMPO) transportation-sector model enables analysis of household choices, with a focus on adoption, charging, and use of electric vehicles. The Scout buildings-sector model supports detailed consideration of the policies and markets that can accelerate the adoption of electrification and energy conservation measures in buildings. Such sector-specific models are instrumental in informing technology research, sectoral planning strategies, and sector-specific aspects of greenhouse gas mitigation strategies in the United States. The integrated multisector and sector-specific modeling approaches represented by GCAM and these sectoral models are complementary. The integrated multisector approach calculates energy pricing and resource allocation within the model, which is important for consistency when future conditions substantially diverge from current conditions in transformative scenarios. The sector-specific approach facilitates representation of granular details across spatial, temporal, technological, and market dimensions that enable exploration of particular interactions and trade-offs. This report presents the results of recent work to explore the differences and trade-offs between these approaches by comparing GCAM with the sector-specific ReEDS, TEMPO, and Scout models. The report compares both model structures and results, and it addresses their potential relevance and applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Inclusive Innovation and Entrepreneurship Roundtable

On June 22, 2021, Pacific Northwest National Laboratory hosted a roundtable to discuss the role that the U.S. Department of Energy (DOE) can play in supporting inclusive and just innovation and entrepreneurship. This roundtable convened individuals from DOE, as well as experts in climate and energy justice, entrepreneurship and innovation, and incubation and acceleration services to understand barriers to entry for communities who have been historically underserved by DOE funding instruments. With the intention of cultivating active discussions among participants, the roundtable was anchored by two rounds of breakout sessions that complemented the RFI addressing inclusive innovation and entrepreneurship in climate technologies that DOE released on June 9, 2021. This report synthesizes the breakout room discussions during the roundtable before presenting overarching themes that were identified from the event.

99 GENERAL AND MISCELLANEOUS↗

Measurement and Analysis of the Extreme Physical Shock Environment Experienced by Crane-Mounted Radiation Detection Systems

At ports of entry, radiation detectors could be mounted on container gantry crane spreaders to monitor cargo containers entering and leaving the country. These detectors would have to withstand the extreme physical conditions experienced by these spreaders during normal operations. Physical shock data from the gable ends of a spreader were recorded during the loading and unloading of a cargo ship by twohard mounted PCB Piezotronics model 340A50 accelerometers and two Lansmont SAVER 9X30 units(with padding). The majority of large shocks were observed in the vertical direction. The Lansmont units recorded mean shocks of 22.215 ±1.174and 23.776 ±1.140g, while the PCB accelerometers recorded mean shocks of 31.608 ±1.798and 37.072 ±2.015g in this direction. Maximum shocks were as high as 118.854 g. A scatter plot of observed peak acceleration versus velocity change is presented to allow comparison with the damage boundary curve for any planned instrumentation for future systems. Furthermore, it is hoped that the results of this research will aid in the design of future crane-mounted systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Dynamic System Scaling Applied to Zr-4 Cladding under RIA Conditions

The research and development lifecycle for new fuel designs currently has an ideal 20-25 year timeline. Efforts are currrently underway to accelerate fuel design and development using high performance fuel modeling codes and reduced scale experiments with new instrumentation techniques. However current tools available require a full scale prototype to be designed and tested for fuel qualification. The thermal-hydraulics community has leveraged scaling methodologies to use reduced scale integral effect test facilities (Westinghouse AP600/1000, NuScale Power Module) in lieu of building full scale prototypes for reactor design certification. Dynamic System Scaling (DSS) is a recent development to scaling methodologies that enable the tracking and quantification of dynamic scaling distortions experienced throughout a transient. Recent TREAT experiments performed reactivity initiated accident (RIA) pulses on UO2 fuel rodlets in Zr-4 cladding and were accompanied by BISON predictions for the cladding temperature. DSS is applied to pyrometer data of outer cladding temperatures and two BISON predictions after peak cladding temperature has been reached. One BISON case uses a constant gap conductance value between the fuel and cladding and the other using a conventional gap conductance model. Results from the DSS analysis show that there is good agreement between both BISON predictions and the experimental data and that there is not a significant distortion seen between using either gap conductance model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electrical condition monitoring method for polymers

An electrical condition monitoring method utilizes measurement of electrical resistivity of an age sensor made of a conductive matrix or composite disposed in a polymeric structure such as an electrical cable. The conductive matrix comprises a base polymer and conductive filler. The method includes communicating the resistivity to a measuring instrument and correlating resistivity of the conductive matrix of the polymeric structure with resistivity of an accelerated-aged conductive composite.

36 MATERIALS SCIENCE↗

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of a flat substrate is changed by placing torques (couples) at each end. Depending on the applied couples, one can tune the shape close to a desired tangential cylinder, ellipse or parabola. We review the nature of the bending, requirements and approaches to the mechanical design, describe original optical and at-wavelength techniques for optimal tuning of bendable optics and alignment on the beamline, and provide beamline performance of the bendable optics used for sub-micro and nano focusing of soft x-rays.

42 ENGINEERING↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

Upgrading the Data Acquisition and Control System of the LANSCE LINAC

Los Alamos National Laboratory LANL is in the process of upgrading the control system for the Los Alamos Neutron Science Center (LANSCE) linear accelerator. The 38 year-old data acquisition and control equipment is being replaced with COTS hardware. An overview of the current system requirements and how the National Instruments cRIO system meets these requirements will be given, as well as an update on the installation and operation of a prototype system in the LANSCE LINAC.

Accelerator Design, Technology, and Operations↗

Multi-nuclide AMS system at the University of Tsukuba

A multi-nuclide AMS system on the 12UD Pelletron tandem accelerator at the University of Tsukuba (Tsukuba AMS system) can measure environmental levels of long-lived radioisotopes of {sup 14}C, {sup 26}Al, {sup 36}Cl and {sup 129}I by employing a molecular pilot beam. AMS is an ultrasensitive technique for the study of long-lived radioisotopes, and stable isotopes at very low abundances. The high terminal voltage has an advantage in the detection of heavy radioisotopes. Much progress has been made in the development of new AMS techniques. For example, a standard deviation of the fluctuation for the {sup 36}Cl/Cl ratio is +- 2%, and the effective detection limit is better than 1x10{sup -15}. In recent years, the main research field of the 12UD Pelletron tandem accelerator has shifted to accelerator mass spectrometry (AMS) research from nuclear physics. This report presents an overview of the Tsukuba AMS system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studies of charmed hadronic B decays with the early LHCb data and prospects for {gamma} measurements

We present the first studies of decays of the type B{yields}DX, where D represents a charmed meson (D{sup 0}, D{sup (*)+}, or D{sub s}) from the LHCb experiment at CERN. Our studies use data accumulated during the 2010 run of the LHC. This work represents the first steps on a programme towards a precision measurement of the angle {gamma} of the CKM Unitarity Triangle. The prospects for this {gamma} measurement will be reviewed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation and Experimental Developments for the Beamlines at the Synchrotron SOLEIL

This paper presents an overview of the instrumentation and experiments developed for the beamlines at Synchrotron SOLEIL in France. Currently fourteen beamlines are opened to users out of the twenty six scheduled. About half of the beamlines cover the soft x-rays region using spectroscopy and imagery techniques. The second half covers the hard x-rays field studying diffraction of matter. Some sample environments carried out for beamlines, for biology, chemistry and surface sciences are described. For the soft x-rays beamlines, carbon contamination of optics is a crucial issue. Different experiments are currently under study in order to reduce or even avoid this effect. Other studies relate to the improvement of metrological methods for beamline optics, to the reduction of vibrational effects for the microbeams and development of computer control for diffractometers. The various types of instruments and experiments will be presented both with an overview of the status of the beamlines in operation and under construction.

43 PARTICLE ACCELERATORS↗

Simbol-X Core Science in a Context

Taking advantage of emerging technology in mirror manufacturing and spacecraft formation flying, Simbol-X will push grazing incidence imaging up to {approx}80 keV, providing an improvement of roughly three orders of magnitude in sensitivity and angular resolution compared to all instruments that have operated so far above 10 keV. This will open a new window in X-ray astronomy, allowing breakthrough studies on black hole physics and census and particle acceleration mechanisms. We discuss here synergies between Simbol-X and the main multiwavelength facilities that will operate in the next decade, and present a quantitative comparison between Simbol-X and its main competitors, NuStar and Astro-H.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-19: A Comparison of the Dosimetric Effects of Brass Mesh and Superflab Boluses

Purpose: We compared the dosimetric effects of brass mesh (Whiting and Davis, Attleboro Falls, MA) and Superflab (CNMC, Nashville, TN) boluses to verify equivalence between the two. Brass mesh bolus may be a convenient alternative to traditional bolus as it better conforms to the skin surface. Methods: Measurements were taken using a 6MV 10×10cm field produced by an Infinity linear accelerator (Elekta, Stockholm, Sweden) in a solid water phantom using a parallel plate ion chamber (Model 96035, Keithley Instruments, Cleveland, OH). Measurements compared 0.5cm and 1cm of Superflab to one to six layers of brass bolus mesh. Measurements were performed at depths from 0cm (‘skin’) to 10cm. Oblique beams were not studied. Results: Four layers of brass mesh were equivalent to 0.5cm Superflab within 5% at all depths. Six layers of brass compares most favorably with 0.5cm Superflab, with doses at all depths within 3%. Six layers of brass were not fully equivalent to 1cm Superflab, although the agreement was within 5% for depths greater than 3mm. Surface dose was 12% lower than 1cm Superflab. Surface dose can be up to 34% different between Superflab and brass mesh, but is less than 5% different with 4–6 layers of brass when compared to 0.5cm Superflab. To achieve surface dose agreement better than 5% compared to 1cm Superflab, more than 6 layers would be needed. The attenuation at depth was a maximum of 0.17cm per layer. Conclusion: Between four and six layers of brass mesh can be equivalent to 0.5cm Superflab, depending on the level of agreement desired. Equivalence within 5% at all depths to 1cm Superflab was not achieved even with six layers. This data agrees with measurements taken by Utsunomiya et al. (2010). More point measurements at shallower depths should be taken prior to clinical implementation of brass bolus mesh.

60 APPLIED LIFE SCIENCES↗

Sci—Thur PM: Imaging — 03: A novel Čerenkov detector based on air-spaced light guiding taper for megavoltage x-ray imaging

Electronic Portal Imaging Devices (EPIDs) have been used in radiation therapy and are still needed on linear accelerators (Linacs) equipped with kilovoltage cone beam CT (kV-CBCT) or MRI systems. Recently a new concept of a high quantum efficiency (QE) Čerenkov Portal Imaging Device (CPID) for MV x-ray imaging in radiation therapy was introduced. It relies on Čerenkov effect for x-ray detection. The proposed design consisted of a matrix of optical fibres aligned with the incident x-rays and coupled to an active matrix flat panel imager (AMFPI) for image readout. A weakness of such design is that too few Čerenkov light photons reach the AMFPI for each incident x-ray and an AMFPI with an avalanche gain is required. In this work we propose to replace the optical fibers in the CPID with light guides without a cladding layer that are suspended in air. The air between the light guides takes on the role of the cladding layer found in a regular optical fiber. Since air has a significantly lower refractive index, a much superior light collection efficiency is achieved. Our Monte Carlo studies have shown that the modified new CPID has a QE more than an order of magnitude greater than that of current clinical systems and yet a spatial resolution similar to that of current flat-panel based EPIDs. Furthermore it has been demonstrated that the new CPID does not require an avalanche gain in the AMFPI and is quantum noise limited at dose levels corresponding to a single Linac pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-AB-BRB-07: Alanine and Monte Carlo Determined Beam Quality Corrections for Nonstandard Fields of the Varian TrueBeam Accelerator

Purpose: To determine beam quality correction factors for flattened and unflattened beams of the Varian TrueBeam™ accelerator using alanine measurements and Monte Carlo calculations. Methods: Measurements were performed using L-α-alanine pellets encased in Virtual Water™ paddles. These were irradiated in liquid water using various field sizes of the 6MV and 10MV beam energies of the TrueBeam™, with both flattening-filter-free (FFF) and flattened beam modes. Measurements were also performed in a 10×10 cm{sup 2} {sup 60}Co field. Pellets were read out by the National Physical Laboratory (NPL, Teddington, UK) using electron paramagnetic resonance (EPR) spectrometry, and results were corrected for energy dependence using graphite calorimetry. Beam quality correction factors (k{sub Q}, k{sub Q}msr,Q, and k{sub Q}clin,Q{sub msr}) were determined for three ionization chambers: an Exradin A12 Farmer-type chamber, an Exradin A1SL scanning chamber, and an Exradin A26 microchamber. All chambers were modeled in the egs-chamber user code of EGSnrc. Sources were created using Varian-supplied IAEA-compliant phase spaces and the BEAMnrc user code, and were validated by comparing measured and simulated dose profiles. Results: Measured and calculated k{sub Q} values agreed within uncertainties, showing the chamber models to be reliable. A comparison of measured and calculated k{sub Q}msr,Q results with TG-51-based values showed that TG-51 adequately accounts for variations in beam quality between flattened and unflattened 10×10 cm{sup 2} fields. Small field corrections, k{sub Q}clin,Q{sub msr}, were determined to be up to 5%, referenced to a 10×10 cm{sup 2} field of the same energy and mode. Conclusion: Beam quality corrections were determined for several beam energies of the TrueBeam™ accelerator using Monte Carlo calculations and were validated using measurements with alanine. Values of k{sub Q} determined using TG-51 were found to be adequate for FFF reference fields. However, small field corrections are necessary for both flattened and unflattened beams to ensure greater treatment planning accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact high-resolution X-ray ion mobility spectrometer

For the ionization of gaseous samples, most ion mobility spectrometers employ radioactive ionization sources, e.g., containing {sup 63}Ni or {sup 3}H. Besides legal restrictions, radioactive materials have the disadvantage of a constant radiation with predetermined intensity. In this work, we replaced the {sup 3}H source of our previously described high-resolution ion mobility spectrometer with 75 mm drift tube length with a commercially available X-ray source. It is shown that the current configuration maintains the resolving power of R = 100 which was reported for the original setup containing a {sup 3}H source. The main advantage of an X-ray source is that the intensity of the radiation can be adjusted by varying its operating parameters, i.e., filament current and acceleration voltage. At the expense of reduced resolving power, the sensitivity of the setup can be increased by increasing the activity of the source. Therefore, the performance of the setup can be adjusted to the specific requirements of any application. To investigate the relation between operating parameters of the X-Ray source and the performance of the ion mobility spectrometer, parametric studies of filament current and acceleration voltage are performed and the influence on resolving power, peak height, and noise is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exposure of Polymeric Glazing Materials Using NREL's Ultra-Accelerated Weathering System (UAWS)

NREL's Ultra-Accelerated Weathering System (UAWS) selectively reflects and concentrates natural sunlight ultraviolet irradiance below 475 nm onto exposed samples to provide accelerated weathering of materials while keeping samples within realistic temperature limits. This paper will explain the design and implementation of the UAWS which allow it to simulate the effect of years of weathering in weeks of exposure. Exposure chamber design and instrumentation will be discussed for both a prototype UAWS used to test glazing samples as well as a commercial version of UAWS. Candidate polymeric glazing materials have been subjected to accelerated exposure testing at a light intensity level of up to 50 UV suns for an equivalent outdoor exposure in Miami, FL exceeding 15 years. Samples include an impact modified acrylic, fiberglass, and polycarbonate having several thin UV-screening coatings. Concurrent exposure is carried out for identical sample sets at two different temperatures to allow thermal effects to be quantified along with resistance to UV.

14 SOLAR ENERGY↗

An Advanced Extreme Environment Wireless Telemetry System for Turbine Blade Instrumentation

As advanced natural gas power generation systems evolve, the thrust for increased efficiencies and reduced emissions results in increasingly harsh conditions inside the turbine environment. These high temperatures, pressures, and corrosive atmospheres result in accelerated rates of degradation, leading to failure of turbine materials and components. The University of Arkansas (UA) and Siemens, in collaboration with the DoE's National Energy Technology Laboratory (NETL), are developing a reliable and long-term monitoring capability in the turbine hot gas path in the form of novel ceramic-based thermocouples and integrated wide band gap instrumentation electronics that will contribute to the overall reliability of gas turbines. When equipped with better monitoring and controls, power plants can operate with increased fuel-burning efficiency, improved process dynamics and gas concentrations, and increased overall longevity of the power plant components. This will result in increased turbine availability and a reduction in outages and maintenance costs. One of the key aspects to driving forward turbine monitoring capability is the development of high temperature capable integrated circuit (IC) electronics. Previous papers have described 500 °C + electronics that were developed primarily from a combination of discrete single transistors combined with supporting high temperature passive components. While these circuits have been tested successfully in high temperature spin test environments, the move to an IC approach will greatly increase the performance and reliability of turbine monitoring systems. This program is developing such capability through the implementation of silicon carbide (SiC) based ICs, and this paper details the initial approach and early testing of the developed devices. This research represents an important step towards the realization of a field deployable high reliability turbine condition monitoring system.

47 OTHER INSTRUMENTATION↗