Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adding Nuclear”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Anaerobic co-digestion of the organic fraction of municipal solid waste with FOG waste from a sewage treatment plant: Recovering a wasted methane potential and enhancing the biogas yield

Anaerobic digestion is applied widely to treat the source collected organic fraction of municipal solid wastes (SC-OFMSW). Lipid-rich wastes are a valuable substrate for anaerobic digestion due to their high theoretical methane potential. Nevertheless, although fat, oil and grease waste from sewage treatment plants (STP-FOGW) are commonly disposed of in landfill, European legislation is aimed at encouraging more effective forms of treatment. Co-digestion of the above wastes may enhance valorisation of STP-FOGW and lead to a higher biogas yield throughout the anaerobic digestion process. In the present study, STP-FOGW was evaluated as a co-substrate in wet anaerobic digestion of SC-OFMSW under mesophilic conditions (37 {sup o}C). Batch experiments carried out at different co-digestion ratios showed an improvement in methane production related to STP-FOGW addition. A 1:7 (VS/VS) STP-FOGW:SC-OFMSW feed ratio was selected for use in performing further lab-scale studies in a 5 L continuous reactor. Biogas yield increased from 0.38 {+-} 0.02 L g VS{sub feed}{sup -1} to 0.55 {+-} 0.05 L g VS{sub feed}{sup -1} as a result of adding STP-FOGW to reactor feed. Both VS reduction values and biogas methane content were maintained and inhibition produced by long chain fatty acid (LCFA) accumulation was not observed. Recovery of a currently wasted methane potential from STP-FOGW was achieved in a co-digestion process with SC-OFMSW.

09 BIOMASS FUELS↗

Integrating remediation and resource recovery: On the economic conditions of landfill mining

Highlights: • We compare two remediation scenarios; one with resource recovery and one without. • Economic analysis includes relevant direct costs and revenues for the landfill owner. • High degrees of metal and/or combustible contents are important economic factors. • Landfill tax and the access to a CHP can have a large impact on the result. • Combining landfill mining and remediation may decrease the project cost. - Abstract: This article analyzes the economic potential of integrating material separation and resource recovery into a landfill remediation project, and discusses the result and the largest impact factors. The analysis is done using a direct costs/revenues approach and the stochastic uncertainties are handled using Monte Carlo simulation. Two remediation scenarios are applied to a hypothetical landfill. One scenario includes only remediation, while the second scenario adds resource recovery to the remediation project. Moreover, the second scenario is divided into two cases, case A and B. In case A, the landfill tax needs to be paid for re-deposited material and the landfill holder does not own a combined heat and power plant (CHP), which leads to disposal costs in the form of gate fees. In case B, the landfill tax is waived on the re-deposited material and the landfill holder owns its own CHP. Results show that the remediation project in the first scenario costs about €23/ton. Adding resource recovery as in case A worsens the result to −€36/ton, while for case B the result improves to −€14/ton. This shows the importance of landfill tax and the access to a CHP. Other important factors for the result are the material composition in the landfill, the efficiency of the separation technology used, and the price of the saleable material.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Temperature Detectors: Principles and Applications

Despite the added cost and complexity of operating at sub-Kelvin temperatures, there are many measurement applications where the sensitivity and precision provided by low temperature detectors greatly outweigh any disadvantages. As a result, low temperature detectors are now finding wide application for measurements ranging from cosmology to homeland defense. In this tutorial I will introduce the basic operating principles and fundamental performance limits of several types of low temperature detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A line-imaging velocity interferometer technique for shock diagnostics without x-ray preheat limitation

A study was conducted with a line-imaging velocity interferometer on sandwich targets at the Shen Guang-III prototype laser facility in China, with the goal of eliminating the preheat effect. A sandwich target structure was used to reduce the x-ray preheat limitation (radiation temperature {approx}170 eV) in a radiative drive shock experiment. With a thick ablator, the preheat effect appeared before the shock arrived at the window. After adding a shield layer of high-Z material on the ablator, x-rays which penetrated the ablator were so weak that the blank-out effect could not be measured. This experiment indicates that the sandwich target may provide a valuable technique in experiments such as equation of state and shock timing for inertial confinement fusion studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations

Purpose: To measure the scattered radiation intensity around a clinical digital breast tomosynthesis (DBT) unit and to provide updated data for radiation shielding design for DBT systems with tungsten-anode x-ray tubes. Methods: The continuous distribution of scattered x-rays from a clinical DBT system (Hologic Selenia Dimensions) was measured within an angular range of 0°–180° using a linear-array x-ray detector (X-Scan 0.8f3-512, Detection Technology, Inc., Finland), which was calibrated for the x-ray spectrum range of the DBT unit. The effects of x-ray field size, phantom size, and x-ray kVp/filter combination were investigated. Following a previously developed methodology by Simpkin, scatter fraction was determined for the DBT system as a function of angle around the phantom center. Detailed calculations of the scatter intensity from a DBT system were demonstrated using the measured scatter fraction data. Results: For the 30 and 35 kVp acquisition, the scatter-to-primary-ratio and scatter fraction data closely matched with data previously measured by Simpkin. However, the measured data from this study demonstrated the nonisotropic distribution of the scattered radiation around a DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous survey performed at MGH, the scatter air kerma at 1 m from the phantom center for wall/door is 1.76 × 10{sup −2} mGy patient{sup −1}, for floor is 1.64 × 10{sup −1} mGy patient{sup −1}, and for ceiling is 3.66 × 10{sup −2} mGy patient{sup −1}. Conclusions: Comparing to previously measured data for mammographic systems, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload (measured with total mAs/week), added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP Report 147 is still sufficient for the Hologic DBT system given the workload from a previous survey at MGH. With the data provided from this study, accurate shielding calculation can be performed for Hologic DBT systems with specific workload and barrier distance.

61 RADIATION PROTECTION AND DOSIMETRY↗

LANL Testing of DTRA Sponsored ARA Portable LIBS Instruments: Isotopic Module [Slides]

The samples were stationary (not rastered during the experiment). Therefore the laser drilled through the powder sample the adhesive and to , the laser drilled through the powder sample, the adhesive and to the substrate (which can be seen in the photograph). <10 laser shots actually ablated sample. The remaining ~50 laser shots added to the spectral noise decreasing the S/N and making an accurate , decreasing the S/N and making an accurate determination of LOD difficult. If the number of laser shots are decreased, the amount of noise will be reduced increasing the S/N and most likely lower the LOD , increasing the S/N and, most likely, lower the LOD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Testing of Optimized Bubbler Configuration for HLW Melter

The principal objective of this work was to determine the glass production rate increase and ancillary effects of adding more bubbler outlets to the current WTP HLW melter baseline. This was accomplished through testing on the HLW Pilot Melter (DM1200) at VSL. The DM1200 unit was selected for these tests since it was used previously with several HLW waste streams including the four tank wastes proposed for initial processing at Hanford. This melter system was also used for the development and optimization of the present baseline WTP HLW bubbler configuration for the WTP HLW melter, as well as for MACT testing for both HLW and LAW. Specific objectives of these tests were to: Conduct DM1200 melter testing with the baseline WTP bubbling configuration and as augmented with additional bubblers. Conduct DM1200 melter testing to differentiate the effects of total bubbler air flow and bubbler distribution on glass production rate and cold cap formation. Collect melter operating data including processing rate, temperatures at a variety of locations within the melter plenum space, melt pool temperature, glass melt density, and melter pressure with the baseline WTP bubbling configuration and as augmented with additional bubblers. Collect melter exhaust samples to compare particulate carryover for different bubbler configurations. Analyze all collected data to determine the effects of adding more bubblers to the WTP HLW melter to inform decisions regarding future lid re-designs. The work used a high aluminum HLW stream composition defined by ORP, for which an appropriate simulant and high waste loading glass formulation were developed and have been previously processed on the DM1200.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress in Chile in the development of the fission {sup 99}Mo production using modified CINTICHEM

Fission {sup 99}Mo will be produced in Chile irradiating low-enriched uranium (LEU) foil in a MTR research reactor. For the purpose of developing the capability to fabricate the target, which is done of uranium foil enclosed in swaged concentric aluminum tubes, dummy targets are being fabricated using 130 {mu}m copper foil instead of the uranium foil, wrapped in a 14{mu}m nickel fission-recoil barrier. Dummy targets using several dimensions of copper foil have been assembled; however, the emphasis is being set in targets fabricated using the dimensions of the LEU foil that KAERI will provide, i.e. 50 mm x 100mm x 0.130 mm. The assembling of target using the last dimensions has not been free of difficulties. Neutronic calculations and preliminary thermal and fluid analyses were performed to estimate the fission products activity and the heat removal capability for a 13 grams LEU-foil annular target, which will be irradiated in the RECH-1 research reactor at the level power of 5 MW during 48 hours. In a fume hood, Cintichem processing of natural uranium shavings with the addition of different carriers were performed, obtaining recovery over 90% of the added Mo carrier. Expertise has been gained in (a) foil dissolution process in a dissolver locally designed, (b) in Mo precipitation process, and (c) preparation of the purification columns with AgC, C and HZrO. Additionally, the irradiated target cutting machine with an innovative design was finally assembled. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Large-scale transient sensitivity analysis of a radiation damaged bipolar junction transistor.

Automatic differentiation (AD) is useful in transient sensitivity analysis of a computational simulation of a bipolar junction transistor subject to radiation damage. We used forward-mode AD, implemented in a new Trilinos package called Sacado, to compute analytic derivatives for implicit time integration and forward sensitivity analysis. Sacado addresses element-based simulation codes written in C++ and works well with forward sensitivity analysis as implemented in the Trilinos time-integration package Rythmos. The forward sensitivity calculation is significantly more efficient and robust than finite differencing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrinos from failed supernovae at future water and liquid argon detectors

We discuss the diffuse flux of electron neutrinos and antineutrinos from cosmological failed supernovae, stars that collapse directly into a black hole with no explosion. This flux has a hotter energy spectrum compared to the flux from regular, neutron star-forming collapses and therefore it dominates the total diffuse flux from core collapses above 20–45 MeV of neutrino energy. Reflecting the features of the originally emitted neutrinos, the flux of ν e and $\bar{v}$e at Earth is larger when the survival probability of these species is larger, and also when the equations of state of nuclear matter are stiffer. In the 19–29 MeV energy window, the flux from failed supernovae is substantial, ranging from ~7% to a dominant fraction of the total flux from all core collapses. It can be as large as Φ $\bar{e}$ BH =0.38 s-1 cm-2 for $\bar{v}$e and as large as Φ $\bar{e}$ BH =0.28 s -1 cm -2 for ν e , normalized to a local rate of core collapses of R cc (0)=10 -4 yr -1 Mpc-3. In 5 years, a 0.45 Mt water Cherenkov detector should see ~5–65 events from failed supernovae, while up to ~160 events are expected for the same mass with Gadolinium added. A 0.1 Mt liquid argon experiment should record ~1–11 events. Signatures of neutrinos from failed supernovae are the enhancement of the total rates of events from core collapses (up to a factor of ~2) and the appearance of high energy tails in the event spectra.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vitrification of Hanford Tank Wastes for Condensate Recycle and Feed Composition Changeover Testing

During the vitrification of Hanford Site nuclear waste at the Waste Treatment and Immobilization Plant (WTP), which is a part of the safe and efficient retrieval, treatment, and disposal mission of the U.S. Department of Energy Office of River Protection, the offgas condensate generated from the waste-to-glass conversion is currently planned to be concentrated by evaporation in the Effluent Management Facility (EMF). This concentrated condensate can then be recycled back to the incoming waste and vitrified. To test the recycle process, an apparatus was designed and built to mimic the EMF evaporator and was then used to concentrate a volume of condensate produced during the vitrification of a sample of Hanford tank 241-AP-107 (referred to herein as AP-107) waste in a continuous laboratory-scale melter (CLSM). The concentrated condensate was added to an additional sample of AP-107 waste, to mimic one round of the recycle process, and the combined solution was vitrified, producing a second round of recycle condensate. In the current study, the EMF test apparatus was used to concentrate the second-round recycle condensate under evaporation conditions (at 45 °C and 1.4 psia) designed to emulate EMF operation. The condensate was successfully concentrated by a factor of ~10 while retaining over 95 % of the technetium-99 ( 99 Tc), Cs, and I inventories in the concentrate. Another portion of AP-107 waste was retrieved by Washington River Protection Solutions, LLC (WRPS) and transferred to Pacific Northwest National Laboratory (PNNL), where it was pretreated and then combined with the second-round recycle AP-107 condensate concentrate and glass-forming chemicals (GFCs) to form the two-time recycle AP-107 melter feed, approximating a second round to the recycling action to be performed at the WTP. A portion of AP-105 waste was also retrieved by WRPS and provided to PNNL for pretreatment and combining with GFCs to form AP-105 melter feed. The two-time recycle AP-107 and AP-105 melter feeds were processed consecutively in the CLSM. The CLSM run proceeded for 13.63 hours, producing 9.70 kg of glass for an average glass production rate of 1464 kg m 2 d -1 during the two-time recycle AP-107 feed charging and 1568 kg m 2 d -1 during the AP-105 feed charging. The rate during AP-107 charging was essentially equivalent to the rate when processing no-recycle AP-107 feed and lower than that achieved when processing one-time recycle AP-107 feed. However, all rates were within the potential range of variability when processing melter feeds with similar composition in the CLSM. Likewise, the rate during AP-105 charging was higher than the previous rate processing AP-105, but within the potential CLSM range. The cold-cap characteristics changed from the typically thin AP-107 cold cap to a foamy-edged cold cap as previously seen with AP-105 shortly after transitioning to the AP-105 melter feed. The glass produced during the CLSM run was within 10 % of its target composition for the primary glass components. The CaO and Li 2 O targets varied by more than 1 wt% between the two-time recycle AP-107 and AP-105 glass targets and it took about 2 turnovers of the CLSM glass inventory to reach a relative chemical steady state in the glass for CaO and Li 2 O after the melter feed inputs were switched. The 99 Tc and total cesium content in the melter feeds were maintained at concentrations expected to be experienced at the WTP. During the CLSM run, while processing the two-time recycle AP-107 melter feed at a relative chemical steady state, the 99 Tc/Cs ratio was 10, and 34% of 99 Tc and 74% of Cs were retained in the glass. These values were higher than those measured in the CLSM run with one-time recycle AP-107 melter feed. After the transition to processing the AP-105 melter feed, when the production reached a relative chemical steady state, the 99 Tc/Cs ratio was 77 while 44% of 99 Tc was retained in the glass. The C's retention during this time frame reached 200% due to the excess C's in the glass after the target content decreased to 15% of its initial level in the two-time recycle AP-107 melter feed to the lower target in the Ap-105 melter feed. While iodine was below inductively coupled plasma mass spectrometry analytical reporting limits in the melter feed and glass samples, it was detected in quantities above the analytical reporting limits in the liquid and filter samples collected from the CLSM offgas treatment system. The behavior of iodine in the CLSM offgas treatment system followed a similar pattern to those of 99 Tc and Cs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synthesis, Development, and Testing of High-Surface-Area Polymer-Based Adsorbents for the Selective Recovery of Uranium from Seawater

The ocean contains uranium with an approximate concentration of 3.34 ppb, which can serve as an incredible supply source to sustain nuclear energy in the United States. Unfortunately, technology currently available to recover uranium from seawater is not efficient enough and mining uranium on land is still more economical. For this study, we have developed polymer-based adsorbents with high uranium adsorption capacities by grafting amidoxime onto high-surface-area polyethylene (PE) fibers. Various process conditions have been screened, in combination with developing a rapid testing protocol (<24 h), to optimize the process. These adsorbents are synthesized through radiation-induced grafting of acrylonitrile (AN) and methacrylic acid (MAA) onto PE fibers, followed by the conversion of nitriles to amidoximes and basic conditioning. In addition, the uranium adsorption capacity, measured in units of g U /kg ads , is greatly increased by reducing the diameter of the PE fiber or changing its morphology. An increase in the surface area of the PE polymer fiber allows for more grafting sites that are positioned in more-accessible locations, thereby increasing access to grafted molecules that would normally be located in the interior of a fiber with a larger diameter. Polymer fibers with hollow morphologies are able to adsorb beyond 1 order of magnitude more uranium from simulated seawater than current commercially available adsorbents. Finally, several high-surface-area fibers were tested in natural seawater and were able to extract 5–7 times more uranium than any adsorbent reported to date.

36 MATERIALS SCIENCE↗

Multi-Reactor Transmutation Analysis Utility (MRTAU,alpha1): Verification

Multi-Reactor Transmutation Utility (MRTAU) is a general depletion/decay algorithm under development at INL to support quick assessment of off-normal fuel cycle scenarios of similar nature to well studied reactor and fuel cycle concepts for which isotopic and cross-section data exists. MRTAU has been used in the past for scoping calculations to determine actinide composition evolution over the course of multiple recycles in Light Water Reactor Mixed Oxide and Sodium cooled Fast Reactor. In these applications, various actinide partitioning scenarios of interest were considered. The code has recently been expanded to include fission product generation, depletion and isotopic evolution over multiple recycles. The capability was added to investigate potential partial separations and/or limited recycling technologies such as Melt-Refining, AIROX, DUPIC or other fuel recycle technology where the recycled fuel stream is not completely decontaminated of fission products prior to being re-irradiated in a subsequent reactor pass. This report documents the code's solution methodology and algorithm as well as its solution accuracy compared to the SCALE6.0 software suite.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

VeraShift I/O Optimization for Ex-core Calculations with VERA

The initial release of Shift in the Virtual Environment for Reactor Applications (VERA) provided users with the ability to perform ex-core calculations. After this release, a task was undertaken to optimize input parameters and output of desired quantities for ex-core calculations. As requested by analysts, this report presents the detailed input and output changes made to VERA to enhance usability. Specifically, some of the major optimizations added were detector and bioshield setup using the VERA common input, updated Shift input defaults, consolidated output, and output of pin importance's. Close interaction between developers, analysts, and users enabled these useful optimization updates, which will be included in the release of VERA 4.1, and some are included in VERA 4.0.1. Under these auspices, this work will continue under the VERA Users Group (VUG).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Vitrification Testing of HLW with High Phosphate

Projections of the number of high level waste (HLW) canisters to be produced in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) (e.g., [1]) are based upon the inventory of the tank wastes, the anticipated performance of the sludge treatment processes, and current understanding of the capability of the borosilicate glass waste form. The WTP HLW melter design, unlike earlier Department of Energy (DOE) melter designs, incorporates a glass bubbler system. The bubblers create active glass pool mixing and thereby improve heat and mass transfer and glass melting rate. The WTP HLW melters each have a glass surface area of 3.75 m 2 and depth of ~1.1 m. The two melters in the HLW facility together are designed to produce up to 7.5 MT of glass per day at 100% availability. Further increases in HLW waste processing rates can potentially be achieved by optimization of the feed and glass formulations, increasing the melter operating temperature above 1150⁰C, and by increasing the waste loading in the glass product. Increasing the waste loading also has the added benefit of decreasing the number of canisters for storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remote Handling and Maintenance in the Facility for Rare Isotope Beams

Michigan State University (MSU) in East Lansing, MI was selected by the U.S. Department of Energy (DOE) to design and establish a Facility for Rare Isotope Beams (FRIB), a cutting-edge research facility to advance the understanding of rare nuclear isotopes and the evolution of the cosmos. The research conducted at the FRIB will involve experimentation with intense beams of rare isotopes within a well-shielded target cell that will result in activation and contamination of components. The target cell is initially hands-on accessible after shutdown and a brief cool-down period. Personnel are expected to have hands-on access to the tops of shielded component modules with the activated in-beam sections suspended underneath. The modules are carefully designed to include steel shielding for protecting personnel during these hand-on operations. However, as the facility has greater levels of activation and contamination, a bridge mounted servomaniputor may be added to the cell, to perform the disconnecting of services to the component assemblies. Dexterous remote handling and exchange of the modularized activated components is completed at a shielded window workstation with a pair of master-slave manipulators. The primary components requiring exchange or maintenance are the production target, the beam wedge filter, the beam dump, and the beam focusing and bending magnets. This paper provides an overview of the FRIB Target Facility remote handling and maintenance design requirements, concepts, and techniques.

36 MATERIALS SCIENCE↗

Improvements to neutron detection of Pu in solvent for an aqueous buffer tank, magnox reprocessing plant, Sellafield - 14216

The PP Active Feed Tank (PPAFT) is a buffer tank that is not safe by geometry and which is located between the Medium Active (MA) and Plutonium Purification (PP) cycles of the chemical separation process in the Magnox Reprocessing Plant. The PPAFT receives Pu nitrate in acid which has been conditioned ready for the extraction of Pu with TBP/OK (tri-butyl phosphate in kerosene) solvent in the PP Cycle. The criticality safety case for the PPAFT recognises that during both normal operations and potential maloperations solvent which is dissolved (TBP which is present in solution but can be released upon a change in acidity) and entrained (TBP/OK physically carried over but not in solution) will accumulate in the PPAFT. The only practicable route out for Pu in solvent in the PPAFT is the normal process route out from the base of the PPAFT to the PP cycle through intermediate vacuum lift and feed vessels. However, the dished end base of the PPAFT and the intermediate vacuum lift and feed vessels are of particularly challenging geometry. There are five neutron monitors placed around the PPAFT for the detection of Pu in solvent. The original design intent of the neutron detection system was that any single monitor should be able to reveal an accumulation of Pu in solvent before it would potentially be unsafe if fed downstream. However, over time there have been changes to the fuel feed and chemical process of the plant which have had the potential to affect the performance of the neutron monitoring system. The ability of the neutron monitoring system to function to its original intent was questioned. Work has recently been carried out to investigate the capabilities of the PPAFT neutron monitoring system for current plant conditions and to identify potential improvements while making best use of the existing neutron monitors. It was found that moving a neutron monitor from the side to the top of the PPAFT and adding alarms based on the ratio of signals from multiple neutron detectors would be effective in improving detection of Pu in solvent. This paper describes the challenges involved in detecting thin layers of Pu in solvent using neutron monitors, discusses the improvements made to the PPAFT neutron monitors and details the combination of real plant data and modelling with the shielding code MCBEND used to provide confidence in the enhanced neutron monitoring system. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Table of experimental nuclear ground state charge radii: An update

The present table contains experimental root-mean-square (rms) nuclear charge radii R obtained by combined analysis of two types of experimental data: (i) radii changes determined from optical and, to a lesser extent, K{sub α} X-ray isotope shifts and (ii) absolute radii measured by muonic spectra and electronic scattering experiments. The table combines the results of two working groups, using respectively two different methods of evaluation, published in ADNDT earlier. It presents an updated set of rms charge radii for 909 isotopes of 92 elements from {sub 1}H to {sub 96}Cm together, when available, with the radii changes from optical isotope shifts. Compared with the last published tables of R-values from 2004 (799 ground states), many new data are added due to progress recently achieved by laser spectroscopy up to early 2011. The radii changes in isotopic chains for He, Li, Be, Ne, Sc, Mn, Y, Nb, Bi have been first obtained in the last years and several isotopic sequences have been recently extended to regions far off stability, (e.g., Ar, Mo, Sn, Te, Pb, Po)

74 ATOMIC AND MOLECULAR PHYSICS↗