Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

ANGULAR MOMENTUM IN GIANT MOLECULAR CLOUDS. II. M33

We present an analysis comparing the properties of 45 giant molecular clouds (GMCs) in M33 and the atomic hydrogen (H I) with which they are associated. High-resolution Very Large Array observations are used to measure the properties of H I in the vicinity of GMCs and in regions where GMCs have not been detected. The majority of molecular clouds coincide with a local peak in the surface density of atomic gas, though 7% of GMCs in the sample are not associated with high surface density atomic gas. The mean H I surface density in the vicinity of GMCs is 10 M{sub sun} pc{sup -2} and tends to increase with GMC mass as {Sigma}{sub HI} {proportional_to} M{sup 0.27}{sub GMC}. Thirty-nine of the 45 H I regions surrounding GMCs have linear velocity gradients of {approx}0.05 km s{sup -1} pc{sup -1}. If the linear gradients previously observed in the GMCs result from rotation, 53% are counterrotating with respect to the local H I. And if the linear gradients in these local H I regions are also from rotation, 62% are counterrotating with respect to the galaxy. If magnetic braking reduced the angular momentum of GMCs early in their evolution, the angular velocity of GMCs would be roughly one order of magnitude lower than what is observed. Based on our observations, we consider the possibility that GMCs may not be rotating. Atomic gas not associated with GMCs has gradients closer to 0.03 km s{sup -1} pc{sup -1}, suggesting that events occur during the course of GMC evolution that may increase the shear in the atomic gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculation of spatial response of 2D beam emission spectroscopy diagnostic on MAST

The beam emission spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a one-dimensional trial system to a two-dimensional imaging system (8 radialx4 poloidal channels) based on a newly developed avalanche photodiode array camera. The spatial resolution of the new system is calculated in terms of the point spread function to account for the effects of field-line curvature, observation geometry, the finite lifetime of the excited state of the beam atoms, and beam attenuation and divergence. It is found that the radial spatial resolution is {approx}2-3 cm and the poloidal spatial resolution {approx}1-5 cm depending on the radial viewing location. The absolute number of detected photons is also calculated, hence the photon noise level can be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

At least 10% shorter C–H bonds in cryogenic protein crystal structures than in current AMBER forcefields

High resolution protein crystal structures resolved with X-ray diffraction data at cryogenic temperature are commonly used as experimental data to refine forcefields and evaluate protein folding simulations. However, it has been unclear hitherto whether the C–H bond lengths in cryogenic protein structures are significantly different from those defined in forcefields to affect protein folding simulations. This article reports the finding that the C–H bonds in high resolution cryogenic protein structures are 10–14% shorter than those defined in current AMBER forcefields, according to 3709 C–H bonds in the cryogenic protein structures with resolutions of 0.62–0.79 Å. Also, 20 all-atom, isothermal–isobaric, 0.5-μs molecular dynamics simulations showed that chignolin folded from a fully-extended backbone formation to the native β-hairpin conformation in the simulations using AMBER forcefield FF12SB at 300 K with an aggregated native state population including standard error of 10 ± 4%. However, the aggregated native state population with standard error reduced to 3 ± 2% in the same simulations except that C–H bonds were shortened by 10–14%. Furthermore, the aggregated native state populations with standard errors increased to 35 ± 3% and 26 ± 3% when using FF12MC, which is based on AMBER forcefield FF99, with and without the shortened C–H bonds, respectively. These results show that the 10–14% bond length differences can significantly affect protein folding simulations and suggest that re-parameterization of C–H bonds according to the cryogenic structures could improve the ability of a forcefield to fold proteins in molecular dynamics simulations. - Highlights: • Cryogenic crystal structures are commonly used in computational studies of proteins. • C–H bonds in the cryogenic structures are shorter than those defined in forcefields. • A survey of 3709 C–H bonds shows that the cryogenic bonds are 10–14% shorter. • The 10–14% differences affect molecular dynamics simulations of protein folding. • Shortening C–H bonds by 10–14% can improve protein folding simulations.

60 APPLIED LIFE SCIENCES↗

Optical knife-edge displacement sensor for high-speed atomic force microscopy

We show that an optical knife-edge technique can be used to detect the parallel shift of an object with sub-nanometer resolution over a wide bandwidth. This allows to design simple, contact-free, and high-speed displacement sensors that can be implemented in high-speed atomic force microscope scanners. In an experimental setup, we achieved a root-mean-square sensor noise of 0.8 nm within a bandwidth from 1 Hz to 1.1 MHz. We used this sensor to detect and correct the nonlinear z-piezo displacement during force curves acquired with rates of up to 5 kHz. We discuss the fundamental resolution limit and the linearity of the sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Science Observations of Deep Space One

During the Deep Space One (DS1) primary mission, the spacecraft will fly by asteroid 1992 KD and possibly comet Borrelly. There are two technologies being validated on DS1 that will provide science observations of these targets, the Miniature Integrated Camera Spectrometer (MICAS) and the Plasma Experiment for Planetary Exploration (PEPE). MICAS encompasses a camera, an ultraviolet imaging spectrometer and an infrared imaging spectrometer. PEPE combines an ion and electron analyzer designed to determine the three-dimensional distribution of plasma over its field of view. MICAS includes two visible wavelength imaging channels, an ultraviolet imaging spectrometer, and an infrared imaging spectrometer all of which share a single 10-cm diameter telescope. Two types of visible wavelength detectors, both operating between about 500 and 1000 nm are used: a CCD with 13-microrad pixels and an 18-microrad-per-pixel, metal-on-silicon active pixel sensor (APS). Unlike the CCD the APS includes the timing and control electronics on the chip along with the detector. The UV spectrometer spans 80 to 185 nm with 0.64-nm spectral resolution and 316-microrad pixels. The IR spectrometer covers the range from 1200 to 2400 nm with 6.6-nm resolution and 54-microrad pixels PEPE includes a very low-power, low-mass micro-calorimeter to help understand plasma-surface interactions and a plasma analyzer to identify de individual molecules and atoms in the immediate vicinity of the spacecraft that have been eroded off the surface of asteroid 1992 KD. It employs common apertures with separate electrostatic energy analyzers. It measures electron and ion energies spanning a range of 3 eV to 30 keV, with a resolution of five percent. and measures ion mass from one to 135 atomic mass units with 5 percent resolution. It electrostatically sweeps its field of view both in elevation and azimuth. Both MICAS and PEPE represent a new direction for the evolution of science instruments for interplanetary spacecraft. These two instruments incorporate a large fraction of the capability of five instruments that had typically flown on NASA's deep space missions The Deep Space One science team acknowledges the support of Philip Varghese, David H. Lehman, Leslie Livesay, and Marc Rayman for providing invaluable assistance in making the science observations possible.

Nelson, Robert M.↗

Control of resonance enhanced multi-photon ionization photoelectron spectroscopy by phase-shaped femtosecond laser pulse

In this paper, we theoretically demonstrate that the (2+1+1) resonance enhanced multi-photon ionization photoelectron spectroscopy in sodium atom can be effectively controlled by shaping femtosecond laser pulse with a {pi} phase step modulation in weak laser field, involving its total photoelectron energy, maximal photoelectron intensity, and spectroscopic bandwidth. Our results show that the total photoelectron energy can be suppressed but not enhanced, the maximal photoelectron intensity can be enhanced and also suppressed, and the photoelectron spectroscopy can be tremendously narrowed. These theoretical results can provide a feasible scheme to achieve the high-resolution photoelectron spectroscopy and study the excited state structure in atomic and molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Growth of non-polar (11-20) InGaN quantum dots by metal organic vapour phase epitaxy using a two temperature method

Non-polar (11-20) InGaN quantum dots (QDs) were grown by metal organic vapour phase epitaxy. An InGaN epilayer was grown and subjected to a temperature ramp in a nitrogen and ammonia environment before the growth of the GaN capping layer. Uncapped structures with and without the temperature ramp were grown for reference and imaged by atomic force microscopy. Micro-photoluminescence studies reveal the presence of resolution limited peaks with a linewidth of less than ∼500 μeV at 4.2 K. This linewidth is significantly narrower than that of non-polar InGaN quantum dots grown by alternate methods and may be indicative of reduced spectral diffusion. Time resolved photoluminescence studies reveal a mono-exponential exciton decay with a lifetime of 533 ps at 2.70 eV. The excitonic lifetime is more than an order of magnitude shorter than that for previously studied polar quantum dots and suggests the suppression of the internal electric field. Cathodoluminescence studies show the spatial distribution of the quantum dots and resolution limited spectral peaks at 18 K.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The future of electron microscopy

Modern transmission electron microscopes can image individual atoms and molecules. But to unlock new science, the next generation of instruments must look beyond just higher spatial resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of the Ti/MgCl{sub 2} interface on a Si(111) 7 x 7 substrate

Photoelectron spectroscopy with synchrotron radiation, low energy electron diffraction, and ion-scattering spectroscopy were used in order to study the Ti/MgCl{sub 2} interface grown on an atomically clean Si(111) 7 x 7 substrate. A series of high resolution spectra after deposition of a thick MgCl{sub 2} layer, step by step deposition of Ti and gradual annealing, indicated a very reactive interface even at room temperature. Strong interaction between the incoming Ti atoms and the MgCl{sub 2} layer, leads to the formation of Ti{sup 2+} and Ti{sup 4+} oxidation states. The interfacial interaction continues even at multilayer Ti coverage mainly by the partial disruption of Mg-Cl bonds and the formation of Ti-Cl sites, rendering this interface a very promising UHV-compatible model of a pre-catalyst for olefin polymerization. After the final annealing, the MgCl{sub 2} multilayers desorb while Ti remains on the surface forming a silicide layer on which Cl and Mg atoms are attached.

36 MATERIALS SCIENCE↗

Expression, purification, crystallization and crystallographic study of Lutzomyia longipalpis LJL143

LJL143, a salivary protein from L. longipalpis, was produced using P. pastoris and crystallized in space group P2{sub 1}2{sub 1}2{sub 1}. Leishmaniasis is a neglected vector-borne disease with a global prevalence of over 12 million cases and 59 000 annual deaths. Transmission of the parasite requires salivary proteins, including LJL143 from the New World sandfly Lutzomyia longipalpis. LJL143 is a known marker of sandfly exposure in zoonotic hosts. LJL143 was crystallized from soluble protein expressed using Pichia pastoris. X-ray data were collected to 2.6 Å resolution from orthorhombic crystals belonging to space group P2{sub 1}2{sub 1}2{sub 1}, with average unit-cell parameters a = 57.39, b = 70.24, c = 79.58 Å. The crystals are predicted to have a monomer in the asymmetric unit, with an estimated solvent content of 48.5%. LJL143 has negligible homology to any reported structures, so the phases could not be determined by molecular replacement. All attempts at S-SAD failed and future studies include experimental phase determination using heavy-atom derivatives.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dielectric spectroscopy at the nanoscale by atomic force microscopy: A simple model linking materials properties and experimental response

The use of an atomic force microscope for studying molecular dynamics through dielectric spectroscopy with spatial resolution in the nanometer scale is a recently developed approach. However, difficulties in the quantitative connection of the obtained data and the material dielectric properties, namely, frequency dependent dielectric permittivity, have limited its application. In this work, we develop a simple electrical model based on physically meaningful parameters to connect the atomic force microscopy (AFM) based dielectric spectroscopy experimental results with the material dielectric properties. We have tested the accuracy of the model and analyzed the relevance of the forces arising from the electrical interaction with the AFM probe cantilever. In this way, by using this model, it is now possible to obtain quantitative information of the local dielectric material properties in a broad frequency range. Furthermore, it is also possible to determine the experimental setup providing the best sensitivity in the detected signal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

REFMAC5 for the refinement of macromolecular crystal structures

The general principles behind the macromolecular crystal structure refinement program REFMAC5 are described. This paper describes various components of the macromolecular crystallographic refinement program REFMAC5, which is distributed as part of the CCP4 suite. REFMAC5 utilizes different likelihood functions depending on the diffraction data employed (amplitudes or intensities), the presence of twinning and the availability of SAD/SIRAS experimental diffraction data. To ensure chemical and structural integrity of the refined model, REFMAC5 offers several classes of restraints and choices of model parameterization. Reliable models at resolutions at least as low as 4 Å can be achieved thanks to low-resolution refinement tools such as secondary-structure restraints, restraints to known homologous structures, automatic global and local NCS restraints, ‘jelly-body’ restraints and the use of novel long-range restraints on atomic displacement parameters (ADPs) based on the Kullback–Leibler divergence. REFMAC5 additionally offers TLS parameterization and, when high-resolution data are available, fast refinement of anisotropic ADPs. Refinement in the presence of twinning is performed in a fully automated fashion. REFMAC5 is a flexible and highly optimized refinement package that is ideally suited for refinement across the entire resolution spectrum encountered in macromolecular crystallography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of Materials Processes in Liquids in the Electron Microscope

Materials synthesis and the functioning of devices often indispensably involve liquid media. But direct visualization of dynamic process in liquids, especially with high spatial and temporal resolution, has been challenging. For solid materials, advances in aberration corrected electron microscopy have made observation of atomic level features a routine practice. Here we discuss the extent to which one can take advantage of the resolution of modern electron microscopes to image phenomenon occuring in liquids. We will describe the fundamentals of two different experimental approaches, closed and open liquid cells. We will illustrate the capabilities of each approach by considering processes in batteries and nucleation and growth of nanoparticles from solution. We conclude that liquid cell electron microscopy appears to be duly fulfilling its role for in situ studies of nanoscale processes in liquids, revealing physical and chemical processes otherwise difficult to observe.

Environmental Molecular Sciences Laboratory↗

Role of Grain Boundary Cr5B3 Precipitates on Intergranular Attack in Alloy 600

It is well established that thermally treated (TT) alloy 600 exhibits superior resistance to intergranular stress corrosion cracking (IGSCC) in pressurized water reactor (PWR) primary water environments than do solution annealed (SA) and mill annealed (MA) equivalents of the same material. This improved resistance is nominally ascribed to the prevalence of grain boundary (GB) Cr-carbide precipitates (M7C3 or M23C6). In this study, we perform high-resolution characterization by scanning transmission electron microscopy (STEM) and atom probe tomography (APT) on a heat of alloy 600 with a very low concentration of C (0.01 at.%) and a modest B concentration (46 appm). After SA+TT annealing, this heat exhibits IG Cr-boride precipitates (Cr5B3) in the absence of Cr carbides. Despite IG precipitation of Cr5B3, the pristine GB shows no measurable Cr depletion and B remains segregated at the GB. During intergranular attack (IGA) in PWR primary water at 360 °C, the Cr5B3 precipitates dissolve rapidly. The observed IGA is subtly different from what is typical for alloy 600, specifically with higher concentrations of Li and B within the corrosion oxides while the GB ahead exhibits less depletion of oxidizing species (e.g. Cr, Fe, Si and B) than other alloy 600 heats. Together these observations suggest that IG precipitation of Cr5B3 in the absence of Cr carbides has a neutral to slightly positive effect on the IG corrosion resistance of alloy 600 GBs in PWR primary water.

alloy 600, APT, TEM↗