Search NASA⌕ Search

SEARCH · Search NASA

Results for “Avoidance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Transition metals in the transition zone: Crystal chemistry of minor element substitution in wadsleyite

As the most abundant solid phase at depths of 410 to 525 km, wadsleyite constitutes a large geochemical reservoir in the Earth. In order to better understand the implications of minor element substitution and cation ordering in wadsleyite, we have synthesized wadsleyites coexisting with pyroxenes with about 3 wt% of either TiO 2 , Cr 2 O 3 , V 2 O 3 , CoO, NiO, or ZnO under hydrous conditions in separate experiments at 1300 °C and 15 GPa. We have refined the crystal structures of these wadsleyites by single-crystal X-ray diffraction, analyzed the compositions by electron microprobe, and estimated M3 vacancy concentration from b/a cell-parameter ratios. According to the crystal structure refinements, trivalent cations Fe 3+ , Cr 3+ and V 3+ , show a strong preference for M3 over M1 and M2 and significant substitution up to 2.7 % (atomic percent) at the tetrahedral site (T site). Divalent cations, Ni 2+ , Co 2+ , and Zn 2+ show site preferences similar to those of Fe2+ with M1≈ M3 > M2 > T. Transition metal site preferences appear to correlate with crystal field stabilization energies (CFSE) and are inconsistent with cation radius effects. The avoidance of Ni 2+ , Co 2+ and Fe 2+ for the M2 site in both wadsleyite and olivine can be influenced by CFSE, which has a positive correlation with site preferences at octahedral sites, indicating that avoidance of the lower-symmetry M2 site is stronger for cations having lower (greater absolute value) CFSE. Ti 4+ substitutes primarily into the M3 octahedron, rather than M1, M2, or T sites. Electron microprobe analysis reveals that Ti 4+ , Cr 3+ , and V 3+ have greater solubility in wadsleyite than in olivine. Furthermore these transition metal cations may be enriched in a melt or an accessory phase if hydrous melting occurs on upward convection across the wadsleyite-olivine boundary and may be useful as indicators of high pressure origin.

36 MATERIALS SCIENCE↗

Capture and Sequestration of CO2 at the Boise White Paper Mill

This report documents the efforts taken to develop a preliminary design for the first commercial-scale CO2 capture and sequestration (CCS) project associated with biomass power integrated into a pulp and paper operation. The Boise Wallula paper mill is located near the township of Wallula in Southeastern Washington State. Infrastructure at the paper mill will be upgraded such that current steam needs and a significant portion of the current mill electric power are supplied from a 100% biomass power source. A new biomass power system will be constructed with an integrated amine-based CO2 capture plant to capture approximately 550,000 tons of CO2 per year for geologic sequestration. A customized version of Fluor Corporation’s Econamine Plus™ carbon capture technology will be designed to accommodate the specific chemical composition of exhaust gases from the biomass boiler. Due to the use of biomass for fuel, employing CCS technology represents a unique opportunity to generate a net negative carbon emissions footprint, which on an equivalent emissions reduction basis is 1.8X greater than from equivalent fossil fuel sources (SPATH and MANN, 2004). Furthermore, the proposed project will offset a significant amount of current natural gas use at the mill, equating to an additional 200,000 tons of avoided CO2 emissions. Hence, the total net emissions avoided through this project equates to 1,100,000 tons of CO2 per year. Successful execution of this project will provide a clear path forward for similar kinds of emissions reduction that can be replicated at other energy-intensive industrial facilities where the geology is suitable for sequestration. This project also represents a first opportunity for commercial development of geologic storage of CO2 in deep flood basalt formations. The Boise paper mill site is host to a Phase II pilot study being carried out under DOE’s Regional Carbon Partnership Program. Lessons learned from this pilot study and other separately funded projects studying CO2 sequestration in basalts will be heavily leveraged in developing a suitable site characterization program and system design for permanent sequestration of captured CO2. The areal extent, very large thickness, high permeability in portions of the flows, and presence of multiple very low permeability flow interior seals combine to produce a robust sequestration target. Moreover, basalt formations are quite reactive with water-rich supercritical CO2 and formation water that contains dissolved CO2 to generate carbonate minerals, providing for long-term assurance of permanent sequestration. Sub-basalt sediments also exist at the site providing alternative or supplemental storage capacity.

03 NATURAL GAS↗

LDRD final report on confinement of cluster fusion plasmas with magnetic fields.

Two versions of a current driver for single-turn, single-use 1-cm diameter magnetic field coils have been built and tested at the Sandia National Laboratories for use with cluster fusion experiments at the University of Texas in Austin. These coils are used to provide axial magnetic fields to slow radial loss of electrons from laser-produced deuterium plasmas. Typical peak field strength achievable for the two-capacitor system is 50 T, and 200 T for the ten-capacitor system. Current rise time for both systems is about 1.7 {mu}s, with peak current of 500 kA and 2 MA, respectively. Because the coil must be brought to the laser, the driver needs to be portable and drive currents in vacuum. The drivers are complete but laser-plasma experiments are still in progress. Therefore, in this report, we focus on system design, initial tests, and performance characteristics of the two-capacitor and ten-capacitors systems. The questions of whether a 200 T magnetic field can retard the breakup of a cluster-fusion plasma, and whether this field can enhance neutron production have not yet been answered. However, tools have been developed that will enable producing the magnetic fields needed to answer these questions. These are a two-capacitor, 400-kA system that was delivered to the University of Texas in 2010, and a 2-MA ten-capacitor system delivered this year. The first system allowed initial testing, and the second system will be able to produce the 200 T magnetic fields needed for cluster fusion experiments with a petawatt laser. The prototype 400-kA magnetic field driver system was designed and built to test the design concept for the system, and to verify that a portable driver system could be built that delivers current to a magnetic field coil in vacuum. This system was built copying a design from a fixed-facility, high-field machine at LANL, but made to be portable and to use a Z-machine-like vacuum insulator and vacuum transmission line. This system was sent to the University of Texas in Austin where magnetic fields up to 50 T have been produced in vacuum. Peak charge voltage and current for this system have been 100 kV and 490 kA. It was used this last year to verify injection of deuterium and surrogate clusters into these small, single-turn coils without shorting the coil. Initial test confirmed the need to insulate the inner surface of the coil, which requires that the clusters must be injected through small holes in an insulator. Tests with a low power laser confirmed that it is possible to inject clusters into the magnetic field coils through these holes without destroying the clusters. The university team also learned the necessity of maintaining good vacuum to avoid insulator, transmission line, and coil shorting. A 200-T, 2 MA system was also constructed using the experience from the first design to make the pulsed-power system more robust. This machine is a copy of the prototype design, but with ten 100-kV capacitors versus the two used in the prototype. It has additional inductance in the switch/capacitor unit to avoid breakdown seen in the prototype design. It also has slightly more inductance at the cable connection to the vacuum chamber. With this design we have been able to demonstrate 1 MA current into a 1 cm diameter coil with the vacuum chamber at air pressure. Circuit code simulations, including the additional inductance with the new design, agree well with the measured current at a charge voltage of 40 kV with a short circuit load, and at 50 kV with a coil. The code also predicts that with a charge voltage of 97 kV we will be able to get 2 MA into a 1 cm diameter coil, which will be sufficient for 200 T fields. Smaller diameter or multiple-turn coils will be able to achieve even higher fields, or be able to achieve 200-T fields with lower charge voltage. Work is now proceeding at the university under separate funding to verify operation at the 2-MA level, and to address issues of debris mitigation, measurement of the magnetic field, and operation in vacuum. We anticipate operation at full current with single-turn, magnetic field coils this fall, with 200 T experiments on the Texas Petawatt laser in the spring of 2012.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Siting Study for a Hydrokinetic Energy Project Located Offshore Southeastern Florida: Protocols for Survey Methodology for Offshore Marine Hydrokinetic Energy Projects

Dehlsen Associates, LLC was awarded a grant by the United States Department of Energy (DOE) Golden Field Office for a project titled 'Siting Study Framework and Survey Methodology for Marine and Hydrokinetic Energy Project in Offshore Southeast Florida,' corresponding to DOE Grant Award Number DE-EE0002655 resulting from DOE funding Opportunity Announcement Number DE-FOA-0000069 for Topic Area 2, and it is referred to herein as 'the project.' The purpose of the project was to enhance the certainty of the survey requirements and regulatory review processes for the purpose of reducing the time, efforts, and costs associated with initial siting efforts of marine and hydrokinetic energy conversion facilities that may be proposed in the Atlantic Ocean offshore Southeast Florida. To secure early input from agencies, protocols were developed for collecting baseline geophysical information and benthic habitat data that can be used by project developers and regulators to make decisions early in the process of determining project location (i.e., the siting process) that avoid or minimize adverse impacts to sensitive marine benthic habitat. It is presumed that such an approach will help facilitate the licensing process for hydrokinetic and other ocean renewable energy projects within the study area and will assist in clarifying the baseline environmental data requirements described in the U.S. Department of the Interior Bureau of Ocean Energy Management, Regulation and Enforcement (formerly Minerals Management Service) final regulations on offshore renewable energy (30 Code of Federal Regulations 285, published April 29, 2009). Because projects generally seek to avoid or minimize impacts to sensitive marine habitats, it was not the intent of this project to investigate areas that did not appear suitable for the siting of ocean renewable energy projects. Rather, a two-tiered approach was designed with the first step consisting of gaining overall insight about seabed conditions offshore southeastern Florida by conducting a geophysical survey of pre-selected areas with subsequent post-processing and expert data interpretation by geophysicists and experienced marine biologists knowledgeable about the general project area. The second step sought to validate the benthic habitat types interpreted from the geophysical data by conducting benthic video and photographic field surveys of selected habitat types. The goal of this step was to determine the degree of correlation between the habitat types interpreted from the geophysical data and what actually exists on the seafloor based on the benthic video survey logs. This step included spot-checking selected habitat types rather than comprehensive evaluation of the entire area covered by the geophysical survey. It is important to note that non-invasive survey methods were used as part of this study and no devices of any kind were either temporarily or permanently attached to the seabed as part of the work conducted under this project.

16 TIDAL AND WAVE POWER↗

Feasibility Study: Ductless Hydronic Distribution Systems with Fan Coil Delivery

Hydronic distribution systems have a long history, and are widely used in commercial buildings. As with mini-split heat pumps, hydronic systems using small terminal fan coils have the potential to provide high-quality comfort to homes that have small heating and cooling loads, but at a lower cost and with greater flexibility. These “ductless hydronic” distribution systems eliminate space requirements needed for ducting, eliminate duct thermal losses, and are easy to zone. Since heat pump chiller-heaters can be charged with refrigerant at the factory, hydronic systems also avoid refrigerant system faults such as incorrect charge and inadequate evacuation of lines that can lead to sub-standard performance. Other advantages include: reduction in the amount of energy required to deliver heating and cooling, reduced equipment cycling, and the potential for incorporating energy storage for peak load avoidance and demand response. Ductless hydronic systems are best suited for new homes, but with the relative ease of installing piping in attic spaces (for example under attic insulation), they are also suitable for existing homes that have old, leaky, and poorly insulated ducts. With a broader and more affordable product offering from manufacturers, installation guidelines, and contractor training, this method of distribution has significant potential to meet the space conditioning needs of high performance homes. The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers. The analysis focuses on ductless hydronic delivery systems that use water-to-air terminal units in each zone. This system type is applicable in all climate regions and can provide sensible and latent cooling and/or heating using a single hot and chilled water source such as a heat pump, or a separate water heater and chiller. Results of TRNSYS modeling indicate that annual heating and cooling energy use (site and source) can be reduced by up to 22% when substituting pipes, pump, small distributed fan coils, and a water-to-air heat pump for the ducts, air handler, indoor coil, and conventional air-to-air heat pump unit of similar rating as the air-to-water unit. Of the 22% savings, on average 36% is attributable to the lower energy required by pumps and small fans vs. air handler blowers, and 64% to the reduced losses from pipes as compared to ducts. Using the modeled energy savings and estimated costs, hydronic distribution appears to be economically viable in three of the four climates evaluated. Other current field studies of air-to-water heat pumps coupled to radiant floor systems are demonstrating heat pump performance that exceeds seasonal performance calculated using a standard heat pump performance map (German, 2011a, German, 2011b). Hydronic distribution systems can meet sensible and latent cooling needs in all climates. Major barriers to widespread application include the lack of low-cost, small, ceiling-mounted fan coils, and the limited availability and higher cost of air-to-water heat pumps. The latter could be overcome by the production of an add-on refrigerant-to-water conversion kit that could be used to adapt any heat pump to serve as a water chiller-heater. Development of accurate performance maps and additional data on field performance are areas that should be targeted by future research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updated Application of Spatial Data Modeling and Geographical Information Systems (GIS) for Identification of Potential Siting Options for Small Modular Reactors

Beginning in late 2008, Oak Ridge National Laboratory (ORNL) responded to ongoing internal and external studies addressing key questions related to our national electrical energy supply. This effort has led to the development and refinement of Oak Ridge Siting Analysis for power Generation Expansion (OR-SAGE), a tool to support power plant siting evaluations. The objective in developing OR-SAGE was to use industry-accepted approaches and/or develop appropriate criteria for screening sites and employ an array of geographic information systems (GIS) data sources at ORNL to identify candidate areas for a power generation technology application. The basic premise requires the development of exclusionary, avoidance, and suitability criteria for evaluating sites for a given siting application such as siting small modular reactors (SMRs). For specific applications of the tool, it is necessary to develop site selection and evaluation criteria (SSEC) that encompass a number of key benchmarks that essentially form the site environmental characterization for that application. These SSEC might include population density, seismic activity, proximity to water sources, proximity to hazardous facilities, avoidance of protected lands and floodplains, susceptibility to landslide hazards, and others.

GIS↗

Disruptions, Disruptivity, and Safer Operating Windows in the High-β Spherical Torus NSTX

This paper discusses disruption rates, disruption causes, and disruptivity statistics in the high- βN National Spherical Torus Experiment (NSTX) [M. Ono, et al. Nuclear Fusion 40, 557 (2000)]. While the overall disruption rate is rather high, configurations with high βN , moderate q*, strong boundary shaping, sufficient rotation, and broad pressure and current profiles are found to have the lowest disruptivity; active n=1 control further reduces the disruptivity. The disruptivity increases rapidly for q*<2.7, which is substantially above the ideal MHD current limit. In quiescent conditions, q min >1.25 is generally acceptable for avoiding the onset of core rotating n=1 kink/tearing modes; when EPM and ELM disturbances are present, the required q min for avoiding those modes is raised to ~1.5. The current ramp and early flat-top phase of the discharges are prone to n=1 core rotating modes locking to the wall, leading to a disruption. Small changes to the discharge fueling during this phase can often mitigate the rotation damping associated with these modes and eliminate the disruption. The largest stored energy disruptions are those that occur at high current when a plasma current rampdown is initiated incorrectly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of API & IEC Standards for Offshore Wind Turbine Applications in the U.S. Atlantic Ocean: Phase II - March 9, 2009 - September 9, 2009

The National Renewable Energy Laboratory (NREL) contracted MMI Engineering to conduct Phase II of the Joint Industry Project on Comparison of two design standards for offshore wind turbines (OWTs) in the United States Outer Continental Shelf waters. The two standards were the American Petroleum Institute (API) RP – 2A Recommended Practice for Planning, Designing, and Constructing Fixed Offshore Platforms and the International Electrotechnical Commission (IEC) 61400-3 Design Requirements for Offshore Wind Turbines. In Phase I, two structure types (a monopile and a tripod) were studied at two sites – offshore Texas at 24-m water depth and offshore Massachusetts at 15-m water depth. This study provided insights into the loads imposed on the structures caused by wind and ocean forces, and also provided insights into the strength (capacity) of the structures subject to these loads. The resulting reliability (annual failure probability for ultimate strength) for the two structures at the two sites were generally governed by turbine and blade resonance avoidance for designing the structure, and not by ultimate strength needs to resist extreme loads. The conclusions drawn from Phase I were based on these limited numbers of case studies. This limitation prompted the need to conduct this second phase to study two new designs, the monopile and a jacket (space frame) substructure, at the same site where ultimate strength would likely also influence design and resonance avoidance. The site selected for Phase II was the offshore Massachusetts site, but with a water depth of 25 m (instead of 15 m as in Phase I). This selection permitted the use of the same meteorological and oceanographic (metocean) parameters, with the breaking wave criteria altered as a result of the increased water depth.

17 WIND ENERGY↗

Analysis of Concentrating Solar Power with Thermal Energy Storage in a California 33% Renewable Scenario

This analysis evaluates CSP with TES in a scenario where California derives 33% of its electricity from renewable energy sources. It uses a commercial grid simulation tool to examine the avoided operational and capacity costs associated with CSP and compares this value to PV and a baseload generation with constant output. Overall, the analysis demonstrates several properties of dispatchable CSP, including the flexibility to generate during periods of high value and avoid generation during periods of lower value. Of note in this analysis is the fact that significant amount of operational value is derived from the provision of reserves in the case where CSP is allowed to provide these services. This analysis also indicates that the 'optimal' configuration of CSP could vary as a function of renewable penetration, and each configuration will need to be evaluated in terms of its ability to provide dispatchable energy, reserves, and firm capacity. The model can be used to investigate additional scenarios involving alternative technology options and generation mixes, applying these scenarios within California or in other regions of interest.

14 SOLAR ENERGY↗

The Fusion Nuclear Science Pathways Assessment

With the strong commitment of the US to the success of the ITER burning plasma mission, and the project overall, it is prudent to consider how to take the most advantage of this investment. The production of energy from fusion has been a long sought goal, and the subject of several programmatic investigations and time line proposals. The nuclear aspects of fusion research have largely been avoided experimentally for practical reasons, resulting in a strong emphasis on plasma science. Meanwhile, ITER has brought into focus how the interface between the plasma and engineering/technology, presents the most challenging problems for design. In fact, this situation is becoming the rule and no longer the exception. ITER will demonstrate the deposition of 0.5 GW of neutron heating to the blanket, deliver a heat load of 10-20 MW/m 2 or more on the divertor, inject 50-100 MW of heating power to the plasma, all at the expected size scale of a power plant. However, in spite of this, and a number of other technologies relevant power plant, ITER will provide a low neutron exposure compared to the levels expected to a fusion power plant, and will purchase its tritium entirely from world reserves accumulated from decades of CANDU reactor operations. Such a decision for ITER is technically well founded, allowing the use of conventional materials and water coolant, avoiding the thick tritium breeding blankets required for tritium self-sufficiency, and allowing the concentration on burning plasma and plasma-engineering interface issues. The neutron fluence experienced in ITER over its entire lifetime will be ~ 0.3 MW-yr/m 2 , while a fusion power plant is expected to experience 120-180 MW-yr/m 2 over its lifetime. ITER utilizes shielding blanket modules, with no tritium breeding, except in test blanket modules (TBM) located in 3 ports on the midplane, which will provide early tests of the fusion nuclear environment with very low tritium production (a few g per year).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Science of Ignition Workshop, Panel 3 Report: Implosion Hydrodynamics

Using an ablation pressure of ~100 Mbars over a period of ~10 ns, the implosion hydrodynamics of an ICF capsule have always been a balance between obtaining high implosion velocities (> 370 km/s), necessary to create sufficient fuel densification (ρR >1g/cm 2 ) and stagnation pressure (> 400 Gbars), while simultaneously attempting to avoid hydrodynamic instabilities and avoid raising the DT fuel entropy much -- either of which frustrates fuel densification and hot spot creation. Ideally, an ICF implosion should have yield within about 50% of 1D, but present evidence from NIC suggests that is not the case and it is presently difficult to estimate the degree to which irradiation asymmetries or high-mode mix, respectively, are contributing to this behavior. If the NIC implosion can resolve any low-mode implosion hydrodynamics issues, there remains the significant challenge of achieving the needed convergence ratios in excess of 30+ without generating unacceptable mid to high-mode instability growth. Indeed, in the handful of NIC shots where the implosion speed was pushed up above ~300 km/s, and which had less than 8% ablator mass remaining, hot spot ion temperature and yield both dropped significantly, with an increase in x-ray brightness, which is consistent with excessive perturbation growth due to hydrodynamic instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Environmental Impacts of Wind Power Development on the Population Biology of Greater Prairie-Chickens

1. We investigated the impacts of wind power development on the demography, movements, and population genetics of Greater Prairie-Chickens (Tympanuchus cupido) at three sites in northcentral and eastern Kansas for a 7-year period. Only 1 of 3 sites was developed for wind power, the 201MW Meridan Way Wind Power Facility at the Smoky Hills site in northcentral Kansas. Our project report is based on population data for prairie chickens collected during a 2-year preconstruction period (2007-2008), a 3-year postconstruction period (2009-2011) and one final year of lek surveys (2012). Where relevant, we present preconstruction data from our field studies at reference sites in the northern Flint Hills (2007-2009) and southern Flint Hills (2006-2008). 2. We addressed seven potential impacts of wind power development on prairie chickens: lek attendance, mating behavior, use of breeding habitat, fecundity rates, natal dispersal, survival rates, and population numbers. Our analyses of pre- and postconstruction impacts are based on an analysis of covariance design where we modeled population performance as a function of treatment period, distance to eventual or actual site of the nearest wind turbine, and the interaction of these factors. Our demographic and movement data from the 6-year study period at the Smoky Hills site included 23 lek sites, 251 radio-marked females monitored for 287 bird-years, and 264 nesting attempts. Our genetic data were based on genotypes of 1,760 females, males and chicks that were screened with a set of 27 microsatellite markers that were optimized in the lab. 3. In our analyses of lek attendance, the annual probability of lek persistence during the preconstruction period was ~0.9. During the postconstruction period, distance to nearest turbine did not have a significant effect on the probability of lek persistence. However, the probability of lek persistence increased from 0.69 at 0 m to 0.89 at 30 km from turbines, and most abandoned lek sites were located <5 km from turbines. Probability of lek persistence was significantly related to habitat and number of males. Leks had a higher probability of persistence in grasslands than agricultural fields, and increased from ~0.2 for leks of 5 males, to >0.9 for leks of 10 or more males. Large leks in grasslands should be a higher priority for conservation. Overall, wind power development had a weak effect on the annual probability of lek persistence. 3. We used molecular methods to investigate the mating behavior of prairie chickens. The prevailing view for lek-mating grouse is that females mate once to fertilize the clutch and that conspecific nest parasitism is rare. We found evidence that females mate multiple times to fertilize the clutch (8-18% of broods, 4-38% of chicks) and will parasitize nests of other females during egg-laying (~17% of nests). Variable rates of parentage were highest in the fragmented landscapes at the Smoky Hills field site, and were lower at the Flint Hills field site. Comparisons of the pre- and postconstruction periods showed that wind energy development did not affect the mating behaviors of prairie chickens. 4. We examined use of breeding habitats by radio-marked females and conducted separate analyses for nest site selection, and movements of females not attending nests or broods. The landscape was a mix of native prairie and agricultural habitats, and nest site selection was not random because females preferred to nest in grasslands. Nests tended to be closer to turbines during the postconstruction period and there was no evidence of behavioral avoidance of turbines by females during nest site selection. Movements of females not attending nests or broods showed that females crossed the site of the wind power development at higher rates during the preconstruction period (20%) than the postconstruction period (11%), and that movements away from turbines were more frequent during the postconstruction period. Thus, wind power development appears to affect movements in breeding habitats but not nest site selection of female prairie chickens during the breeding season. 5. We tested the effects of wind power development on five components of female fecundity: timing of clutch initiation, clutch size of first nests and renests, nest survival, and hatchability of eggs. Average date of clutch initiation was 26 April, clutch size was 12.7 and 10.6 eggs for first nests and renests, probability of nest survival was low at 0.18, but egg hatchability was high at 0.79. Wind power development had no impact on reproductive effort or nesting success, and all five components of fecundity were not related to treatment period or distance to turbine. Nest survival was the main factor limiting reproductive output of female prairie chickens and most losses were due to predation. Daily nest survival was strongly related to vegetative cover at the nest. Changes to rangeland management practices that would double nesting cover from 2.5 to 5 dm would triple the probability of nest survival from 0.17 to 0.52. Grass and forb cover had weak positive effects on daily nest survival whereas shrub cover, proximity to woodlands, and recent rainfall had negative effects. Reproductive performance of prairie chickens is low in managed rangelands in northcentral Kansas and efforts to improve range conditions and reduce predator activity would aid recovery of prairie chicken populations. 6. We used molecular methods to investigate patterns of natal dispersal in prairie chickens. High rates of nest failure limited the number of young that we could sample. Direct detections of natal dispersal were limited because survival of newly hatched chicks to become adults were low and because we were unable to detect dispersal distances outside of our study area. Direct observations of natal movements were limited and were inadequate to make conclusions about the potential impacts of wind energy development on natal dispersal. Spatial correlograms of genetic distance among males at leks were a more sensitive measure of population structure, and indicated a weak effect of wind energy development on the spatial genetic structure of prairie chickens. 7. We tested the effects of wind power development on female survival with time-to-event models, and on residual body mass of males with analyses of covariance. Distance to turbine and the interaction of distance and treatment period had no effect on female survival. Contrary to predictions of negative impacts of wind power development, the probability of female was lowest during the preconstruction period (0.274) and increased significantly during the postconstruction period (0.543). Inspection of hazard functions indicated that the difference in annual survival could be attributed to a higher risk of mortality during the lekking season in the preconstruction period. We suggest that wind power development may have improved ecological conditions for prairie chickens by disrupting the foraging behavior of diurnal raptors that kill prairie chickens at lek sites. In support of this idea, raptor kills tended to be farther from turbines during the postconstruction period whereas mammalian kills were closer. Analyses of the major causes of mortality did not support our hypothesis because the odds of raptor predation were greater after development was completed. Most mortality losses of radio-marked females were due to predation, and losses to collision mortality or harvest were rare events. Low rates of natural mortality during fall and winter imply that harvest is likely to be additive mortality in prairie chickens. Wind energy development reduced the residual body mass of male Greater Prairie-Chickens at lek sites near turbines. Low values of residual body mass could have a negative impact on individual survival or fecundity rates, or may be related to predation risk and flight performance of males displaying at open lek sites. 8. We tested for impacts of wind power development on population numbers of prairie chickens with monitoring of male numbers at leks, and with genetic measures of population structure. Lek counts indicated that wind power development did not affect the population size of prairie chickens. Peak counts of males at leks were recorded the first year after construction was completed and the highest rates of population change were observed during the interval when the wind power facility was constructed. Population numbers of prairie chickens near and distant from turbines appeared to covary in parallel, probably because bird numbers were linked by dispersal movements. Estimates of population viability based on genetic diversity, effective population size and rates of population exchange did not show annual changes and were unaffected by wind development during our study. Estimates of relatedness among males at the same and different leks suggested that wind power development has either reduced dispersal rates or changed settlement patterns, leading to higher rates of relatedness among males displaying at the same lek site. 9. Greater Prairie-Chickens were not strongly affected by wind power development in Kansas. Negative impacts of wind power development included a trend for reductions in lek persistence near turbines, behavioral avoidance of turbines by females during their breeding season movements, and changes in the genetic structure of males at leks that were consistent with reduced dispersal or recruitment rates. We found no impacts of wind power development on nest site selection, female reproductive effort or nesting success, or population numbers. Positive impacts of wind power development included an increase in female survival rates. We hypothesized that the unexpected increase in female survival was related to changes in trophic interactions and disruption of the foraging behavior of raptors that kill prairie chickens at lek site. 10. Research funding for this project included a grant from the 20% Wind by 2030 Program of the Department of Energy (this final report), and grants from the Kansas Department of Wildlife, Parks and Tourism, the National Fish and Wildlife Federation, and initial funding from the National Wind Coordinating Collaborative. Research products from data collected during the preconstruction period have included five peer-reviewed research articles and two PhD dissertations at Kansas State University. Additional manuscripts are in review for possible publication in 2013-2014.

17 WIND ENERGY↗

Computer Modeling and Analysis of Truck Generated Salt-Spray Transport Near Bridges

Bridge painting is very expensive. Over the lifetime of a bridge, painting to protect the steel from the elements can cost a large fraction of the original construction cost. In addition to monetary costs, maintenance workers face health risks if strict procedures are not in place to avoid exposure to hazardous dust when old paint is removed and the fumes of hazardous chemicals when new paint is applied. Use of weathering steel in bridge construction avoids the large cost of periodic painting and the hazards of paint removal and repainting because this type of steel is never painted. When exposed to weather, the initial corrosion of weathering steel forms a natural corrosion resistant layer that prevents further corrosion under a wide variety of conditions. Given the advantages of using weathering steel, the choice might appear to be obvious. However, the large potential savings in bridge maintenance costs in using weathering steel are not always realized because the protective patina layer fails to adhere when the steel is exposed to excessively salt-laden and moisture-laden environments. A multi-year study is underway by the FHWA to better quantify the conditions that lead to excessive corrosion in weathering steel bridges. This report documents work using computational fluid dynamics (CFD) analysis to study the conditions and mechanisms that lead from the salt spray thrown from truck tires to salt water droplets reaching bridge girders. Computer simulations use the advanced motion modeling capability called a “sliding mesh” in the CFD software to move one or more large trucks under bridges at 60 mph. The computations include multiphase spray droplet tracking of salt-laden water droplets coming off the tires.

Lottes, S. A.↗

Transport Phenomena and Interfacial Kinetics in Planar Microfluidic Membraneless Fuel Cells

Our work is focused on membraneless laminar flow fuel cells, an unconventional fuel cell technology, intended to create a system that not only avoids most typical fuel cell drawbacks, but also achieves the highest power density yet recorded for a non-H 2 fuel cell. We have employed rigorous electrochemistry to characterize the high-energy- density fuel BH 4 - , providing important mechanistic insight for anode catalyst choice and avoiding deleterious side reactions. Numerous fuel cell oxidants, used in place of O 2 , are compared in a detailed, uniform manner, and a powerful new oxidant, cerium ammonium nitrate (CAN), is described. The high-voltage BH 4 - /CAN fuel/oxidant combination is employed in a membraneless, room temperature, laminar-flow fuel cell, with herringbone micromixers which provide chaotic-convective flow which, in turn, enhances both the power output and efficiency of the device. We have also been involved in the design of a scaled-up version of the membraneless laminar flow fuel cell intended to provide a 10W output.

30 DIRECT ENERGY CONVERSION↗

Symmetry Breaking, Unification, and Theories Beyond the Standard Model

A model was constructed in which the supersymmetric fine-tuning problem is solved without extending the Higgs sector at the weak scale. We have demonstrated that the model can avoid all the phenomenological constraints, while avoiding excessive fine-tuning. We have also studied implications of the model on dark matter physics and collider physics. I have proposed in an extremely simple construction for models of gauge mediation. We found that the {mu} problem can be simply and elegantly solved in a class of models where the Higgs fields couple directly to the supersymmetry breaking sector. We proposed a new way of addressing the flavor problem of supersymmetric theories. We have proposed a new framework of constructing theories of grand unification. We constructed a simple and elegant model of dark matter which explains excess flux of electrons/positrons. We constructed a model of dark energy in which evolving quintessence-type dark energy is naturally obtained. We studied if we can find evidence of the multiverse.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using architecture information and real-time resource state to reduce power consumption and communication costs in parallel applications.

As computer systems grow in both size and complexity, the need for applications and run-time systems to adjust to their dynamic environment also grows. The goal of the RAAMP LDRD was to combine static architecture information and real-time system state with algorithms to conserve power, reduce communication costs, and avoid network contention. We devel- oped new data collection and aggregation tools to extract static hardware information (e.g., node/core hierarchy, network routing) as well as real-time performance data (e.g., CPU uti- lization, power consumption, memory bandwidth saturation, percentage of used bandwidth, number of network stalls). We created application interfaces that allowed this data to be used easily by algorithms. Finally, we demonstrated the benefit of integrating system and application information for two use cases. The first used real-time power consumption and memory bandwidth saturation data to throttle concurrency to save power without increasing application execution time. The second used static or real-time network traffic information to reduce or avoid network congestion by remapping MPI tasks to allocated processors. Results from our work are summarized in this report; more details are available in our publications [2, 6, 14, 16, 22, 29, 38, 44, 51, 54].

Brandt, James M.↗

Measure Guideline: Supplemental Dehumidification in Warm-Humid Climates

This document covers a description of the need and applied solutions for supplemental dehumidification in warm-humid climates, especially for energy efficient homes where the sensible cooling load has been dramatically reduced. In older homes in warm-humid climates, cooling loads are typically high and cooling equipment runs a lot to cool the air. The cooling process also removes indoor moisture, reducing indoor relative humidity. However, at current residential code levels, and especially for above-code programs, sensible cooling loads have been so dramatically reduced that the cooling system does not run a lot to cool the air, resulting in much less moisture being removed. In these new homes, cooling equipment is off for much longer periods of time especially during spring/fall seasons, summer shoulder months, rainy periods, some summer nights, and some winter days. In warm-humid climates, those long off periods allow indoor humidity to become elevated due to internally generated moisture and ventilation air change. Elevated indoor relative humidity impacts comfort, indoor air quality, and building material durability. Industry is responding with supplemental dehumidification options, but that effort is really in its infancy regarding year-round humidity control in low-energy homes. Available supplemental humidity control options are discussed. Some options are less expensive but may not control indoor humidity as well as more expensive and comprehensive options. The best performing option is one that avoids overcooling and avoids adding unnecessary heat to the space by using waste heat from the cooling system to reheat the cooled and dehumidified air to room-neutral temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable Nonlinear Compact Schemes

In this work, we focus on compact schemes resulting in tridiagonal systems of equations, specifically the fifth-order CRWENO scheme. We propose a scalable implementation of the nonlinear compact schemes by implementing a parallel tridiagonal solver based on the partitioning/substructuring approach. We use an iterative solver for the reduced system of equations; however, we solve this system to machine zero accuracy to ensure that no parallelization errors are introduced. It is possible to achieve machine-zero convergence with few iterations because of the diagonal dominance of the system. The number of iterations is specified a priori instead of a norm-based exit criterion, and collective communications are avoided. The overall algorithm thus involves only point-to-point communication between neighboring processors. Our implementation of the tridiagonal solver differs from and avoids the drawbacks of past efforts in the following ways: it introduces no parallelization-related approximations (multiprocessor solutions are exactly identical to uniprocessor ones), it involves minimal communication, the mathematical complexity is similar to that of the Thomas algorithm on a single processor, and it does not require any communication and computation scheduling.

97 MATHEMATICS AND COMPUTING↗