Solar flare gamma-ray line profiles

Solar gamma-ray lines are produced through collisions of pairs of positive ions whose center of mass energies are above the relevant thresholds for excitation of gamma-ray emitting states. Because of the low density of the solar plasma, prompt gamma rays are emitted by recoiling ions before significant energy loss has occurred. Thus, the lines are expected to be Doppler-broadened to widths of the order of a hundred KeV. Gamma-ray lines resulting from proton and alpha-particle (He-4 ion) beams on carbon and oxygen targets in the laboratory exhibit complex profiles which change rapidly with the gamma-ray observation angle. Earlier work has been limited to modeling laboratory and solar flare gamma-ray profiles produced by proton excitation, but laboratory profiles of the carbon 4.44-MeV line and oxygen 6.13-MeV line from alpha excitation have now been successfully modeled. Solar flare gamma-ray line profiles of the carbon and oxygen lines from heavy ions in the ambient solar medium interacting with representative high-energy proton and alpha particle populations are presented.

Lang, F. L.↗

Laser frequency upshift and self-defocusing under avalanche breakdown of air

A theoretical model of avalanche breakdown of air by a Gaussian laser beam and frequency upshift is developed. The laser beam, below the threshold for tunnel ionization, heats the seed electrons to high energy and initiates avalanche ionization of the air. The ensuing plasma density profile that has maximum on axis and falls off radially causes refraction divergence of the beam. The temporal evolution of plasma density causes self-phase modulation of the laser, causing frequency broadening and spectral emission in the visible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Replenishing liquid sheet targets to enable high-intensity high-repetition-rate laser–plasma interactions for ion-beam technology

We report on the development of a robust microfluidic nozzle capable of generating replenishing liquid sheet targets with sub-micron thickness at up to kHz repetition rates, a λ/20 surface flatness over areas of at least 100 μm 2 , and in-vacuum dimensions of 6 × 1.5 mm 2 . The platform was evaluated for stability under hundreds of 4.3 J laser shots at 0.5 Hz and 6 × 10 20 W/cm 2 peak intensity, delivered in burst mode, totaling 2.9 kJ on the target. The key metrics of the platform, including sheet characteristics, nozzle aperture morphology, and proton spectra, showed no measurable degradation in the performance of the liquid sheet platform following this experiment. Beyond its application to ion beam technology, we outline a pathway to further develop the capabilities of the platform into a high-repetition-rate plasma mirror.

depth profiling techniques↗

SU-F-T-68: Characterizes of Microdetectors in Electron Beam Dosimetry

Purpose: Electron beam dosimetry requires high resolution data due to finite range that can be accomplished with small volume detectors. The small-field used in advance technologies in photon beam has created a market for microdetectors, however characteristics are significantly variable in photon beams and relatively unknown in electron beam that is investigated in this study. Methods: Among nearly 2 dozen microdetectors that have been investigated in small fields of photon beam, two popular detectors (microDiamond 60019 (PTW)) and W1 plastic scintillator detector (Standard Imaging)) that are tissue equivalent and have very small sensitive volume are selected. Electron beams from Varian linear accelerators were used to investigate dose linearity dose rate dependence, energy dependence, depth dose and profiles in a reference condition in a water phantom. For W1 that has its own Supermax electrometer point by point measurements were performed. For microDiamond, a PTW-scanning tank was used for both scanning and point dose measurements. Results: W1 detector showed excellent dose linearity (r{sup 2} =1.0) from 5–500 MU either with variation of dose rate or beam energy. Similar findings were also observed for microdiamond with r{sup 2}=1.0. Percent variations in dose/MU for W1 and microDiamond were 0.2–1.1% and 0.4–1.2%, respectively among dose rate and beam energy. This variation was random for microDiamond, whereas it decreased with beam energy and dose rate for W1. The depth dose and profiles were within ±1 mm for both detectors. Both detectors did not show any energy dependence in electron beams. Conclusion: Both microDiamond and W1 detectors provided superior characteristics of beam parameters in electron beam including dose, dose rate linearity and energy independence. Both can be used in electron beam except W1 require point by point measurements and microdiamond requires 1500 MU for initial quenching.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Core-Pedestal Plasma Configurations in Advanced Tokamaks

Here, several configurations for the core and pedestal plasma are examined for a predefined tokamak design by implementing multiple heating/current drive (H/CD) sources to achieve an optimum configuration of high fusion power in a noninductive operation while maintaining an ideally magnetohydrodynamic (MHD) stable core plasma using the IPS-FASTRAN framework. IPS-FASTRAN is a component-based lightweight coupled simulation framework that is used to simulate magnetically confined plasma by integrating a set of high-fidelity codes to construct the plasma equilibrium (EFIT, TOQ, and CHEASE), calculate the turbulent heat and particle transport fluxes (TGLF), model various H/CD systems (TORIC, TORAY, GENRAY, and NUBEAM), model the pedestal pressure and width (EPED), and estimate the ideal MHD stability (DCON). The TGLF core transport model and EPED pedestal model are used to self-consistently predict plasma profiles consistent with ideal MHD stability and H/CD (and bootstrap) current sources. In order to evaluate the achievable and sustainable plasma beta, varying configurations are produced ranging from the no-wall stability to with-wall stability regimes, simultaneously subject to the self-consistent TGLF, EPED, and H/CD source profile predictions that optimize configuration performance. The pedestal density, plasma current, and total injected power are scanned to explore their impact on the target plasma configuration, fusion power, and confinement quality. A set of fully noninductive scenarios are achieved by employing ion-cyclotron, neutral beam injection, helicon, and lower-hybrid H/CDs to provide a broad profile for the total current drive in the core region for a predefined tokamak design. These noninductive scenarios are characterized by high fusion gain (Q ~ 4) and power (P fus ~ 600 MW), optimum confinement quality (H 98 ~ 1.1), and high bootstrap current fraction (f BS ~ 0.7) for Greenwald fraction below unity. The broad current profile configurations identified are stable to low-n kink modes either because the normalized pressure β N is below the no-wall limit or a wall is present.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spontaneous polarization driven Mg concentration profile reconstruction in MgZnO/ZnO heterostructures

Atomic reconstruction at the interface of MgZnO and ZnO in molecular beam epitaxy grown heterostructures is investigated. Using secondary ion mass spectroscopy, we experimentally find that Mg atomic reconstruction depends on the polarity of the interface; it is not observed in n-type interfaces (MgZnO on Zn-polar ZnO) owing to electron accumulation, while in p-type interfaces (ZnO on Zn-polar MgZnO), Mg drastically redistributes into the ZnO layer. Combined with self-consistent calculation of band profiles and carrier distributions, we reveal that the observed Mg reconstruction is not due to thermal diffusion but consequences in order to avoid hole accumulation. This tendency implies inherent significant asymmetry of energy scales of atomic and electronic reconstructions between n-type and p-type interfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray characterization of contact holes for block copolymer lithography

The directed self-assembly (DSA) of block copolymers (BCPs) is a promising low-cost approach to patterning structures with critical dimensions (CDs) which are smaller than can be achieved by traditional photolithography. The CD of contact holes can be reduced by assembling a cylindrical BCP inside a patterned template and utilizing the native size of the cylinder to dictate the reduced dimensions of the hole. This is a particularly promising application of the DSA technique, but in order for this technology to be realized there is a need for three-dimensional metrology of the internal structure of the patterned BCP in order to understand how template properties and processing conditions impact BCP assembly. This is a particularly challenging problem for traditional metrologies owing to the three-dimensional nature of the structure and the buried features. By utilizing small-angle X-ray scattering and changing the angle between the incident beam and sample we can reconstruct the three-dimensional shape profile of the empty template and the residual polymer after self-assembly and removal of one of the phases. A two-dimensional square grid pattern of the holes results in scattering in both in-plane directions, which is simplified by converting to a radial geometry. The shape is then determined by simulating the scattering from a model and iterating that model until the simulated and experimental scattering profiles show a satisfactory match. Samples with two different processing conditions are characterized in order to demonstrate the ability of the technique to evaluate critical features such as residual layer thickness and sidewall height. It was found that the samples had residual layer thicknesses of 15.9 ± 3.2 nm and 4.5 ± 2.2 nm, which were clearly distinguished between the two different DSA processes and in good agreement with focused ion beam scanning transmission electron microscopy (FIBSTEM) observations. The advantage of the X-ray measurements is that FIBSTEM characterizes around ten holes, while there are of the order of 800,000 holes illuminated by the X-ray beam.

Sunday, Daniel F.↗

Motivations for early high-profile FRIB experiments

This white paper is the result of a collaboration by many of those that attended a workshop at the facility for rare isotope beams (FRIB), organized by the FRIB Theory Alliance (FRIB-TA), on ‘Theoretical Justifications and Motivations for Early High-Profile FRIB Experiments’. It covers a wide range of topics related to the science that will be explored at FRIB. After a brief introduction, the sections address: section 2: Overview of theoretical methods, section 3: Experimental capabilities, section 4: Structure, section 5: Near-threshold Physics, section 6: Reaction mechanisms, section 7: Nuclear equations of state, section 8: Nuclear astrophysics, section 9: Fundamental symmetries, and section 10: Experimental design and uncertainty quantification.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-J-174: Adaptive PET-Based Dose Painting with Tomotherapy

Purpose: PET imaging can be converted into dose prescription directly. Due to the variability of the intensity of PET the image, PET prescription maybe superior over uniform dose prescription. Furthermore, unlike the case in image reconstruction of not knowing the image solution in advance, the prescribed dose is known from a PET image a priori. Therefore, optimum beam orientations are derivable. Methods: We can assume the PET image to be the prescribed dose and invert it to determine the energy fluence. The same method used to reconstruct tissue images from projections could be used to solve the inverse problem of determining beam orientations and modulation patterns from a dose prescription [10]. Unlike standard tomographic reconstruction of images from measured projection profiles, the inversion of the prescribed dose results in photon fluence which may be negative and therefore unphysical. Two-dimensional modulated beams can be modelled in terms of the attenuated or exponential radon transform of the prescribed dose function (assumed to be the PET image in this case), an application of a Ram-Lak filter, and inversion by backprojection. Unlike the case in PET processing, however, the filtered beam obtained from the inversion represents a physical photon fluence. Therefore, a positivity constraint for the fluence (setting negative fluence to zero) must be applied (Brahme et al 1982, Bortfeld et al 1990) Results: Truncating the negative profiles from the PET data results in an approximation of the derivable energy fluence. Backprojection of the deliverable fluence is an approximation of the dose delivered. The deliverable dose is comparable to the original PET image and is similar to the PET image. Conclusion: It is possible to use the PET data or image as a direct indicator of deliverable fluence for cylindrical radiotherapy systems such as TomoTherapy.

60 APPLIED LIFE SCIENCES↗

Positron Annihilation Studies In Polymer Nano-Composites

Positron annihilation spectroscopy coupled with a variable mono-energy positron beam has been applied to study nanoscale polymeric nanocomposites. New information about multilayer depth profiles and structures, interfacial free-volume and open space properties have been obtained in polystyrene/carbon nano fiber composites. The S parameter in Doppler Broadening Energy Spectra combined slow positron beam is used to quantitatively represent the free volume, open spaces, and interactions in the interface between polystyrene matrix and carbon nanofibers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recent improvements of the JET lithium beam diagnostic

A 60 kV neutral lithium diagnostic beam probes the edge plasma of JET for the measurement of electron density profiles. This paper describes recent enhancements of the diagnostic setup, new procedures for calibration and protection measures for the lithium ion gun during massive gas puffs for disruption mitigation. New light splitting optics allow in parallel beam emission measurements with a new double entrance slit CCD spectrometer (spectrally resolved) and a new interference filter avalanche photodiode camera (fast density and fluctuation studies).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of 2D density profiles using a second-harmonic, dispersion interferometer

A second-harmonic, dispersion interferometer is used to image large-area (≃5 cm 2 ) plasma-jet and gas-jet density profiles. Achromatic telescopes magnify the diameters of the primary-laser beam (1064 nm) and its second-harmonic (532 nm) before probing the sample and de-magnify the beam diameters after the sample, where the primary beam transfers its phase change to a second, second-harmonic beam, allowing the sample’s dispersive-phase change to be measured between two, orthogonally polarized second harmonic beams. The telescopes produce an azimuthally symmetric, dispersive-phase shift in the sample + background phase-change image and in the background phase-change image, which is removed by digital subtraction. The interferometer’s performance was verified using standard-optical components as dispersive elements (BK7 lenses and wedge plates), resolving a minimum, phase-change sensitivity of ΔΦ min ≳ 15 mrad and spatial resolution of Δx res ≃ 100 μm. The phase change produced by unknown-density objects (a pulsed-plasma-jet and a pulsed-gas-jet) was measured, and their data were used to recover the original, 2D density profiles using an inverse Abel transform: peak-number density, N gas ≃ 6 × 10 20 cm –3 and N e ≃ 5 × 10 16 cm –3 ; line-integrated density, ∫N gas dl ~ 2 × 10 19 cm –2 and ∫N e dl ~ 1 × 10 16 cm –2 . The techniques and methods developed here are scalable to even larger probe-beam diameters and frame-capture rates, leading to a diagnostic capability that is well-suited for applications involving the real-time measurement of density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tidal Energy Resource Characterization, Bottom Lander Measurements, Cook Inlet, AK, 2021

These datasets are from tidal resource characterization measurements collected on the Terrasond High Energy Oceanographic Mooring (THEOM) from 1 July 2021 to 30 August 2021 (60 days) in Cook Inlet, Alaska. The lander was deployed at 60.7207031 N, 151.4294998 W in ~50 m of water. The dataset contains raw and processed data from the following two instruments: 1. A Nortek Signature 500 kHz acoustic Doppler current profiler (ADCP). Data were recorded in 4 Hz in the beam coordinate system from all 5 beams. Processed data has been averaged into 5 minutes bins and converted to the East-North-Up (ENU) coordinate system. 2. A Nortek Vector acoustic Doppler velocimeter (ADV). Data were recorded at 8 Hz in the beam coordinate system. Processed data has been averaged into 5 minutes bins and converted to the Streamwise - Cross-stream - Vertical (Principal) coordinate system. Turbulence statistics were calculated from 5-minute bins, with an FFT length equal to the bin length, and saved in the processed dataset. Data was read and analyzed using the DOLfYN (version 1.0.2) python package and saved in MATLAB (.mat) and netCDF (.nc) file formats. Files containing analyzed data (".b1") were standardized using the TSDAT (version 0.4.2) python package. NetCDF files can be opened using DOLfYN (e.g., `dat = dolfyn.load(''*.nc")`) or the xarray python package (e.g. `dat = xarray.open_dataset("*.nc"). All distances are in meters (e.g., depth, range, etc), and all velocities in m/s. See the DOLfYN documentation linked in the submission, and/or the Nortek documentation for additional details.

16 TIDAL AND WAVE POWER↗

SU-E-T-405: Evaluation of the Raystation Electron Monte Carlo Algorithm for Varian Linear Accelerators

Purpose: To evaluate the Raystation v4.51 Electron Monte Carlo algorithm for Varian Trilogy, IX and 2100 series linear accelerators and commission for clinical use. Methods: Seventy two water and forty air scans were acquired with a water tank in the form of profiles and depth doses, as requested by vendor. Data was imported into Rayphysics beam modeling module. Energy spectrum was modeled using seven parameters. Contamination photons were modeled using five parameters. Source phase space was modeled using six parameters. Calculations were performed in clinical version 4.51 and percent depth dose curves and profiles were extracted to be compared to water tank measurements. Sensitivity tests were performed for all parameters. Grid size and particle histories were evaluated per energy for statistical uncertainty performance. Results: Model accuracy for air profiles is poor in the shoulder and penumbra region. However, model accuracy for water scans is acceptable. All energies and cones are within 2%/2mm for 90% of the points evaluated. Source phase space parameters have a cumulative effect. To achieve distributions with satisfactory smoothness level a 0.1cm grid and 3,000,000 particle histories were used for commissioning calculations. Calculation time was approximately 3 hours per energy. Conclusion: Raystation electron Monte Carlo is acceptable for clinical use for the Varian accelerators listed. Results are inferior to Elekta Electron Monte Carlo modeling. Known issues were reported to Raysearch and will be resolved in upcoming releases. Auto-modeling is limited to open cone depth dose curves and needs expansion.

43 PARTICLE ACCELERATORS↗

A new method to calculate the beam charge for an integrating current transformer

The integrating current transformer (ICT) is a magnetic sensor widely used to precisely measure the charge of an ultra-short-pulse charged particle beam generated by traditional accelerators and new laser-plasma particle accelerators. In this paper, we present a new method to calculate the beam charge in an ICT based on circuit analysis. The output transfer function shows an invariable signal profile for an ultra-short electron bunch, so the function can be used to evaluate the signal quality and calculate the beam charge through signal fitting. We obtain a set of parameters in the output function from a standard signal generated by an ultra-short electron bunch (about 1 ps in duration) at a radio frequency linear electron accelerator at Tsinghua University. These parameters can be used to obtain the beam charge by signal fitting with excellent accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly efficient electron vortex beams generated by nanofabricated phase holograms

We propose an improved type of holographic-plate suitable for the shaping of electron beams. The plate is fabricated by a focused ion beam on a silicon nitride membrane and introduces a controllable phase shift to the electron wavefunction. We adopted the optimal blazed-profile design for the phase hologram, which results in the generation of highly efficient (25%) electron vortex beams. This approach paves the route towards applications in nano-scale imaging and materials science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

H-mode Accelerating Structures with PMQ Focusing for Low-Beta Beams

We report on results of the project developing high-efficiency normal-conducting RF accelerating structures based on inter-digital H-mode (IH) cavities and the transverse beam focusing with permanent-magnet quadrupoles (PMQ), for beam velocities in the range of a few percent of the speed of light. The shunt impedance of IH-PMQ structures is 10-20 times higher than that of a conventional drift-tube linac, while the transverse size is 4-5 times smaller. The H-PMQ accelerating structures following a short RFQ can be used both in the front end of ion linacs or in stand-alone applications. Results of the combined 3-D modeling -- electromagnetic computations, beam-dynamics simulations with high currents, and thermal-stress analysis -- for a full IH-PMQ accelerator tank are presented. The accelerating field profile in the tank is tuned to provide the best propagation of a 50-mA deuteron beam using coupled iterations of EM and beamdynamics modeling. Multi-particle simulations withParmela and CST Particle Studio have been used to confirm the design. Measurement results of a cold model of the IH-PMQ tank are presented.

Accelerator Design, Technology, and Operations↗