Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

Calculation of spatial distribution of optical escape factor and its application to He I collisional-radiative model

An integral analytical formula for a spatial distribution of the optical escape factor (OEF) in an infinite cylindrical plasma is derived as a function of an arbitrary upper state spatial density profile, the temperature ratio of the upper state to the lower state, and the optical depth of the corresponding transition. Test calculations are carried out for three different upper state profiles, i.e., uniform (rectangular), parabolic, and Gaussian upper state profiles. The OEF takes on negative values at the periphery of the parabolic and Gaussian upper state profiles. These characteristics cannot be expressed by the conventional OEF formulas derived for the center of the plasma, even though the optical depth is increased. In addition to the analytical derivation of the formula, two practical formulas are proposed: an empirical formula of the spatial distribution of the OEF for the Gaussian upper state density profile and a linear formula of the OEF distribution for upper state profiles that are expressed as linear combinations. These formulas enable us to calculate the spatial distribution of the OEF for the multiple-Gaussian upper state profile without the need for time-consuming integral calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Relationship of Ion Beams and Fast Flows in the Plasma Sheet Boundary Layer

We report new findings on the behavior of plasmas in the vicinity of the plasma sheet boundary layer (PSBL). A large geometrical factor detector on WIND (3D plasma experiment) has discovered a unidirectional ion beam streaming in the tailward direction missed by previous observations. This tailward beam is as intense as the earthward streaming beam and it is found just inside the outer edge of the PSBL where earthward streaming beams are observed. The region where this tailward beam is observed includes an isotropic plasma component which is absent in the outer edge where earthward streaming beams are found. When these different distributions are convolved to calculate the velocity moments, fast flows (greater than 400 km/s) result in the earthward direction and much slower flows (less than 200 km/s) in the tailward direction. These new findings are substantially different from previous observations. Thus, the interpretation of fast flows and earthward and counterstreaming ion beams in terms of a neutral line model must be reexamined.

Parks, G. K.↗

Artifacts from manganese reduction in rock samples prepared by focused ion beam (FIB) slicing for X-ray microspectroscopy

The spatial distribution oftransition metal valence states is of broad interest in the microanalysis ofgeological and environmental samples. An example is rock varnish, a naturalmanganese (Mn)-rich rock coating, whose genesis mechanism remains a subjectof scientific debate. We conducted scanning transmission X-ray microscopywith near-edge X-ray absorption fine-structure spectroscopy (STXM-NEXAFS)measurements of the abundance and spatial distribution of different Mnoxidation states within the nano- to micrometer thick varnish crusts. Suchmicroanalytical measurements of thin and hard rock crusts require samplepreparation with minimal contamination risk. Focused ion beam (FIB) slicingwas used to obtain ~100–1000 nm thin wedge-shaped slices of thesamples for STXM, using standard parameters. Yet, while this preparationis suitable for investigating element distributions and structures in rocksamples, we observed artifactual modifications of the Mn oxidation states atthe surfaces of the FIB slices. Our results imply that the preparationcauses a reduction of Mn 4+ to Mn 2+ . We draw attention tothis issue, since FIB slicing, scanning electron microscopy (SEM) imaging,and other preparation and visualization techniques operating in thekilo-electron-volt range are well-established in geosciences, but researchersare often unaware of the potential for the reduction of Mn and possibly otherelements in the samples.

58 GEOSCIENCES↗

Production of warm ions in electron beam generated E × B plasma

Several recent experiments have demonstrated low-damage processing of 2D materials, such as graphene and single crystal diamond, using electron beam (e-beam) generated plasmas with applied crossed electric and magnetic (E × B) fields. Here, the low damage of these sensitive materials is commonly attributed to the low energy of ions incident to the substrate surface and the ion confinement in E x B fields. In this work, measurements of atom and ion velocity distribution functions in an e-beam E × B plasma at sub-mTorr argon pressures using a laser-induced fluorescence diagnostic revealed the presence of a warm population of ions with temperatures of ~ 1 eV that are sufficient to destroy the ion confinement in E × B fields and drive the ion flux by cross field diffusion in the direction opposite to the applied electric field, toward the plasma-bounded walls or substrate. Thus, it is this nearly ambipolar diffusion process that is responsible for the flux of charged particles impinging on the wall/substrate surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation Of Human Body Radiation Using Phantom Model On Beam lowbar nrc And Verification On Dosxyz lowbar nrc

The optimum dose can be produced by measuring and analysis of the dose distribution from the source. The energy of the source must be maximum for the target cell, and must minimum for the tissues that surround the target cell. In this study, the phantom model has a cylindrical shape with 20 cm radius and 19 cm depth. The calculation is done where photon beam energy is 6 MeV with 3 different radius beam; 0.3 cm, 5 cm, and 15 cm. The verification was done with a model cube film which was arranged by element voxel which made by Mylar and Ag. The results of this simulation shows the difference dose distribution for radius beam 0.5 cm, 3 cm, and 15 cm that is caused by particle density and penumbra effect. And for all beam radiuses, the maximum dose (100%) happens in 1.5-2 mm depth from film model.

07 ISOTOPE AND RADIATION SOURCES↗

Dosimetry estimation on variations of patient size in prostate volumetric-modulated arc therapy

This study investigated the dosimetric variations of the target and critical organs of patients who had weight loss associated with prostate volumetric-modulated arc therapy (VMAT). Five patients with prostate volumes ranging from 32–86.5 cm{sup 3} were selected from a group of 30 patients. Prostate VMAT plans were carried out on each patient using the 6-MV photon beam with a single 360° arc. Decrease of patient size as a result of weight loss was mimicked by contracting the patient's external contour in the anterior, left, and right directions with depths from 0.5–2 cm. Soft tissue excluded by the contracted external contour was replaced by air and the dose distribution was recalculated using the same beam geometry and dose prescription. Dose-volume histograms and dose-volume points such as D99% and D5% for the planning target volume (PTV), clinical target volume (CTV), rectum, bladder, and femoral heads were calculated with variations of reduced depth. In addition, the minimum, maximum, and mean doses for the target and critical organs were determined. PTV and CTV D99% were found to have increased 2.86 ± 0.30% per cm and 2.75 ± 0.38% per cm of reduced depth ranging from 0.5–2 cm. Moreover, the rectal and bladder D30% increased 2.20 ± 0.20% per cm and 2.31 ± 0.83% per cm, and the femoral head D5% increased 3.30 ± 0.11% per cm of reduced depth. Results from variations of the minimum, maximum, and mean doses of the PTV, CTV, rectum, bladder, and femoral heads showed that there was a >5% increase of dose when the reduced depth reached 2 cm. This study provided dosimetry estimation for radiation oncology staff to justify dose variations of the target and critical organs when patients' weight loss occurred in prostate VMAT. Dose variations >5% were seen when the patients' reduced depth was equal to 2 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Stimulated emission tomography for efficient characterization of spatial entanglement

Stimulated-emission tomography (SET) is an excellent tool for characterizing the process of spontaneous parametric down conversion (SPDC), which is commonly used to create pairs of entangled photons for use in quantum information protocols. The use of stimulated emission increases the average number of detected photons by several orders of magnitude compared to the spontaneous process. In a SET measurement, the parametric down conversion is seeded by an intense signal field prepared with specified mode properties rather than by broadband multimodal vacuum fluctuations, as is the case for the spontaneous process. The SET process generates an intense idler field in a mode that is the complex conjugate to the signal mode. In this work we use SET to estimate the joint spatial mode distribution (JSMD) in the Laguerre-Gaussian (LG) basis of the two photons of an entangled photon pair. The pair is produced by parametric down conversion in a beta barium borate (BBO) crystal with type-II phase matching pumped at a wavelength of 405 nm along with a 780 nm seed signal beam prepared in a variety of LG modes to generate an 842 nm idler beam of which the spatial mode distribution is measured. We observe strong idler production and good agreement with the theoretical prediction of its spatial mode distribution. Our experimental procedure should enable the efficient determination of the photon-pair wavefunctions produced by low-brightness SPDC sources and the characterization of high-dimensional entangled-photon pairs. Published by the American Physical Society 2024

Xu, Yang (ORCID:0009000954547320)↗

Ionization-induced dynamics of laser-matter interaction in a focused laser pulse: A comparative analysis

We study the laser-matter interaction via optical-field ionization of a medium in a focused ultrashort laser pulse by means of the finite-difference-time-domain modeling of Maxwell's equations. General aspects of the ionization-induced dynamics with TE- and TM-polarized laser pulses are analyzed. It is shown that there are two qualitatively different regimes of the interaction depending on the angle of the laser beam focusing. At comparatively low angles plasma distributions are smooth; however, due to departure from the quasioptical behavior of light rays in self-generated plasma, lateral large-scaled plasma structures can also be produced, leading to additional beam focusing and correspondingly to higher electron densities. At tight focusing, small-scaled plasma structures are generated that strongly influence field distribution, energy deposition, and scattering characteristics. The influence of electron collisions and the Kerr effect are also analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-G-TeP2-13: Patient-Specific Reduction of Range Uncertainties in Proton Therapy by Proton Radiography with a Multi-Layer Ionization Chamber

Purpose: The conversion from Hounsfield units (HU) to stopping powers is a major source of range uncertainty in proton therapy (PT). Our contribution shows how proton radiographs (PR) acquired with a multi-layer ionization chamber in a PT center can be used for accurate patient positioning and subsequently for patient-specific optimization of the conversion from HU to stopping powers. Methods: A multi-layer ionization chamber was used to measure the integral depth-dose (IDD) of 220 MeV pencil beam spots passing through several anthropomorphic phantoms. The whole area of interest was imaged by repositioning the couch and by acquiring a 45×45 mm{sup 2} frame for each position. A rigid registration algorithm was implemented to correct the positioning error between the proton radiographs and the planning CT. After registration, the stopping power map obtained from the planning CT with the calibration curve of the treatment planning system was used together with the water equivalent thickness gained from two proton radiographs to generate a phantom-specific stopping power map. Results: Our results show that it is possible to make a registration with submillimeter accuracy from proton radiography obtained by sending beamlets separated by more than 1 mm. This was made possible by the complex shape of the IDD due to the presence of lateral heterogeneities along the path of the beam. Submillimeter positioning was still possible with a 5 mm spot spacing. Phantom specific stopping power maps obtained by minimizing the range error were cross-verified by the acquisition of an additional proton radiography where the phantom was positioned in a random but known manner. Conclusion: Our results indicate that a CT-PR registration algorithm together with range-error based optimization can be used to produce a patient-specific stopping power map. Sylvain Deffet reports financial funding of its PhD thesis by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work. Francois Vander Stappen reports being employed by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work.

60 APPLIED LIFE SCIENCES↗

Heating of the ambient ionosphere by an artificially injected electron beam

An electrostatic analyzer on the electron accelerator of the Electron Echo 2 experiment showed that the electrons of the background plasma were heated to 10,000 K or more within 8 ms of the start of gun pulses. The degree of heating was dependent on the orientation of the rocket with respect to the magnetic field but was not measurably dependent on ambient electron density, neutral atmosphere density, or on the pitch angle at which the 40-keV electron beam was injected. This heating was also accompanied by an increase of plasma density. No evidence was found for an ion-free region around the rocket during gun pulses. These observations show that significant amounts of ionization are taking place around the rocket. During part of the flight a two-temperature electron distribution was found. It is believed that the high-temperature part of these distributions represents secondaries produced by the beam.

Cartwright, D. G.↗

Interactions of satellite-speed helium atoms with satellite surfaces. 2: Energy distributions of reflected helium atoms

Energy transfer in collisions of satellite-speed (7,000 m/sec) helium atoms with a cleaned 6061-T6 satellite-type aluminum surface was investigated using the molecular-beam technique. The amount of energy transferred was determined from the measured energy of the molecular-beam and the measured spatial and energy distributions of the reflected atoms. Spatial distributions of helium atoms scattered from a 6061-T6 aluminum surface were measured. The scattering pattern exhibits a prominent backscattering, probably due to the gross surface roughness and/or the relative lattice softness of the aluminum surface. Energy distributions of reflected helium atoms from the same surface were measured for six different incidence angles. For each incidence angle, distributions were measured at approximately sixty scattering positions. At a given scattering position, the energy spectra of the reflected helium atoms and the background gas were obtained using the retarding-field energy analyzer.

Liu, S. M.↗

Application of Goubau Surface Wave Transmission Line for Improved Bench Testing of Diagnostic Beamline Elements

In-air test fixtures for beamline elements typically utilize an X-Y positioning stage, and a wire antenna excited by an RF source. In most cases, the antenna contains a standing wave, and is useful only for coarse alignment measurements in CW mode. A surface-wave (SW) based transmission line permits RF energy to be launched on the wire, travel through the beamline component, and then be absorbed in a load. Since SW transmission lines employ travelling waves, the RF energy can be made to resemble the electron beam, limited only by ohmic losses and dispersion. Although lossy coaxial systems are also a consideration, the diameter of the coax introduces large uncertainties in centroid location. A SW wire is easily constructed out of 200 micron magnet wire, which more accurately approximates the physical profile of the electron beam. Benefits of this test fixture include accurate field mapping, absolute calibration for given beam currents, Z-axis independence, and temporal response measurements of sub-nanosecond pulse structures. Descriptions of the surface wave launching technique, transmission line, and instrumentation are presented, along with measurement data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Disentangling Effects of Nuclear Structure in Heavy Element Formation

Forming the same heavy compound nucleus with different isotopes of the projectile and target elements allows nuclear structure effects in the entrance channel (resulting in static deformation) and in the dinuclear system to be disentangled. Using three isotopes of Ti and W, forming {sup 232}Cm, with measurement spanning the capture barrier energies, alignment of the heavy prolate deformed nucleus is shown to be the main reason for the broadening of the mass distribution of the quasifission fragments as the beam energy is reduced. The complex, consistently evolving mass-angle correlations that are observed carry more information than the integrated mass or angular distributions, and should severely test models of quasifission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-A-19A-04: Latent Uncertainties and Performance of a GPU-Implemented Pre-Calculated Track Monte Carlo Method

Purpose: Assessing the performance and uncertainty of a pre-calculated Monte Carlo (PMC) algorithm for proton and electron transport running on graphics processing units (GPU). While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from recycling a limited number of tracks in the pre-generated track bank is missing from the literature. With a proper uncertainty analysis, an optimal pre-generated track bank size can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pre-generated for electrons and protons using EGSnrc and GEANT4, respectively. The PMC algorithm for track transport was implemented on the CUDA programming framework. GPU-PMC dose distributions were compared to benchmark dose distributions simulated using general-purpose MC codes in the same conditions. A latent uncertainty analysis was performed by comparing GPUPMC dose values to a “ground truth” benchmark while varying the track bank size and primary particle histories. Results: GPU-PMC dose distributions and benchmark doses were within 1% of each other in voxels with dose greater than 50% of Dmax. In proton calculations, a submillimeter distance-to-agreement error was observed at the Bragg Peak. Latent uncertainty followed a Poisson distribution with the number of tracks per energy (TPE) and a track bank of 20,000 TPE produced a latent uncertainty of approximately 1%. Efficiency analysis showed a 937× and 508× gain over a single processor core running DOSXYZnrc for 16 MeV electrons in water and bone, respectively. Conclusion: The GPU-PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty below 1%. The track bank size necessary to achieve an optimal efficiency can be tuned based on the desired uncertainty. Coupled with a model to calculate dose contributions from uncharged particles, GPU-PMC is a candidate for inverse planning of modulated electron radiotherapy and scanned proton beams. This work was supported in part by FRSQ-MSSS (Grant No. 22090), NSERC RG (Grant No. 432290) and CIHR MOP (Grant No. MOP-211360)

07 ISOTOPE AND RADIATION SOURCES↗

Vector and tensor analyzing powers of elastic deuteron-proton scattering at 130 MeV deuteron beam energy

High precision vector and tensor analyzing power data of the deuteron-proton elastic scattering at 130 MeV deuteron beam energy have been measured in a large range of angles. They are compared with theoretical predictions obtained in various approaches: with realistic potentials for pure NN interactions, with the inclusion of a three-nucleon force, and in the framework of chiral perturbation theory. All the theoretical calculations describe roughly the main features of the measured distributions, but none of them can reproduce all their details. This indicates the need for further development of the three-nucleon force models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Spectral Method for Halo Particle Definition in Intense Mis-matched Beams

An advanced spectral analysis of a mis-matched charged particle beam propagating through a periodic focusing transport lattice is utilized in particle-in-cell (PIC) simulations. It is found that the betatron frequency distribution function of a mismatched space-charge-dominated beam has a bump-on-tail structure attributed to the beam halo particles. Based on this observation, a new spectral method for halo particle definition is proposed that provides the opportunity to carry out a quantitative analysis of halo particle production by a beam mismatch. In addition, it is shown that the spectral analysis of the mismatch relaxation process provides important insights into the emittance growth attributed to the halo formation and the core relaxation processes. Finally, the spectral method is applied to the problem of space-charge transport limits.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗