Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High Efficiency, Low Cost RF Sources for Accelerators and Colliders

Calabazas Creek Research, Inc. (CCR) and its collaborators are developing high efficiency, low cost RF sources. Phase and Amplitude Controlled Magnetrons: CCR, Fermilab, and Communications & Power Industries, LLC (CPI) recently developed a 100 kW, 1.3 GHz magnetron system with amplitude and phase control. The system operated at more than 80% efficiency and demonstrated rapid control of amplitude and phase. Multiple Beam Triodes: CCR, in collaboration with CPI and JP Accelerator Works, Inc., is developing 200 kW, pulsed and CW RF sources from 350 to 700 MHz with projected efficiencies exceeding 80% and cost of $0.50/Watt. Prototype tubes are scheduled for tests in spring 2021. High Efficiency Klystrons:CCR, CPI, and Leidos, Inc. are building a 1.3 GHz, 100 kW klystron operating at 80% efficiency. High power testing is scheduled for summer 2021. Multiple Beam IOTs: CCR and Georgia Tech Research Institute are developing MBIOTs with simplified input coupling and high efficiency. Simulations indicate that 3rd harmonic drive power can increase the efficiency 8-10 %. The program is developing a prototype tube to produce 200 kW peak, 100 kW average power at 704 MHz.

43 PARTICLE ACCELERATORS↗

Getting to Net Zero

Buildings have a significant impact on energy use and the environment. Commercial and residential buildings use almost 40% of the primary energy and approximately 70% of the electricity in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems

With the current movement toward net zero energy buildings, many technologies are promoted with emphasis on their superior energy efficiency. The variable refrigerant flow (VRF) and ground source heat pump (GSHP) systems are probably the most competitive technologies among these. However, there are few studies reporting the energy efficiency of VRF systems compared with GSHP systems. In this article, a preliminary comparison of energy efficiency between the air-source VRF and GSHP systems is presented. The computer simulation results show that GSHP system is more energy efficient than the air-source VRF system for conditioning a small office building in two selected US climates. In general, GSHP system is more energy efficient than the air-source VRV system, especially when the building has significant heating loads. For buildings with less heating loads, the GSHP system could still perform better than the air-source VRF system in terms of energy efficiency, but the resulting energy savings may be marginal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Multi-State Model for Catalyzing the National Home Energy Retrofit Market (Final Technical Report)

In the fall of 2010, the Alabama Department of Economic and Community Affairs (ADECA) launched the Multi-State Model for Catalyzing the National Home Energy Retrofit Market Project (Multi-State Project). This residential energy efficiency pilot program was a collaborative effort among the states of Alabama, Massachusetts, Virginia, and Washington, and was funded by competitive State Energy Program (SEP) awards through the U.S. Department of Energy (DOE). The objective of this project was to catalyze the home energy efficiency retrofit market in select areas within the state of Alabama. To achieve this goal, the project addressed a variety of marketplace elements that did not exist, or were underdeveloped, at the outset of the effort. These included establishing minimum standards and credentials for marketplace suppliers, educating and engaging homeowners on the benefits of energy efficiency and addressing real or perceived financial barriers to investments in whole-home energy efficiency, among others. The anticipated effect of the activities would be increased market demand for retrofits, improved audit to retrofit conversion rates and growth in overall community understanding of energy efficiency. The four-state collaborative was created with the intent of accelerating market transformation by allowing each state to learn from their peers, each of whom possessed different starting points, resources, and strategies for achieving the overall objective. The four partner states engaged the National Association of State Energy Officials (NASEO) to oversee a project steering committee and to manage the project evaluation for all four states. The steering committee, comprised of key program partners, met on a regular basis to provide overall project coordination, guidance, and progress assessment. While there were variances in program design among the states, there were several common elements: use of the Energy Performance Score (EPS) platform; an audit and home energy rating tool; emphasis on community based coordination and partnerships; marketing and outreach to increase homeowner participation; training for market actors; access to financing options including rebates, incentives, and loan products; and an in depth process evaluation to support continual program improvement and analysis. In Alabama, Nexus Energy Center operated energy efficiency retrofit programs in Huntsville and Birmingham. In the Huntsville community the AlabamaWISE program was available in five Alabama counties: Cullman, Lawrence, Limestone, Madison, and Morgan. In Birmingham, the program was available to residents in Jefferson and Shelby Counties. In both communities, the program was similar in terms of program design but tailored marketing and partnerships to address the unique local conditions and population of each community. ADECA and the Southeast Energy Efficiency Alliance (SEEA) provided overall project management services and common resources to the local program administrator Nexus Energy Center, including contracted services for contractor training, quality assurance testing, data collection and reporting, and compliance. The fundamental components of the AlabamaWISE program included a vertical contractor-based business model; comprehensive energy assessments; third-party quality assurance; rebates for installation of energy saving measures; accessible, low-interest financing; targeted and inbound marketing; Energy Performance Score (EPS) tool to engage and educate homeowners; training for auditors, contractors, and real estate professionals; and online resources for education and program enrollment. Program participants were eligible to receive rebates or financing toward the assessments and upgrades to their home provided they reached at least 20 percent deemed or modeled energy savings. The design of each program focused on addressing several known barriers including: limited homeowner knowledge on the benefits of energy efficiency, lack of financing options, lack of community support for energy efficiency programs, and lack of trained market actors including contractors and real estate professionals. The programs were able to make progress on addressing all of these barriers and were most successful in offering financing options and training market actors. The most challenging barriers proved to be the act of building a market for energy efficiency where none previously existed, convincing homeowners of the value in investing in energy efficiency (and therefore completing retrofits), engaging electric and natural gas utilities to partner on delivery, and achieving the overall project target of 1,365 completed retrofits. The components that proved to be the most valuable to program success were engaged contractor networks that could promote and endorse the program, partnerships with local business and organizations, and the access to rebates, incentives and financing mechanisms. The programs were successful in building relationships with a variety of community participants including: local contractors, Associations of REALTORS, home builders associations, universities, utilities, local and state governments, and other non-profit organizations. Throughout this program, 933 building audits and 795 building retrofits were completed making homes in Alabama more comfortable, less expensive to operate, more valuable to the marketplace, and safer and healthier for families. Continuing on this momentum, Nexus Energy Center plans to continue operating and expanding operations in Alabama as a Home Performance with ENERGY STAR sponsor and will continue to provide energy services and education to communities in Alabama.

Grimes, Elizabeth M.↗

Piloting the Use of Energy Policy Data to Drive Market Action

Information is only useful when put to use. Across the U.S., an ever-growing number of state and local jurisdictions are implementing building performance reporting laws regarding building energy and water use in the commercial and multifamily sectors. This wealth of performance information is not yet being deployed to its full potential to drive smarter business decisions and increase energy savings. Recognizing that this information can help advance energy efficiency in cities, in 2015 the Institute for Market Transformation (IMT) partnered with New York City and the District of Columbia and local groups, NYCEEC and the District of Columbia Sustainable Energy Utility, on a three-year project to understand and document how, exactly, this data can and should be integrated to reap an array of benefits for cities, energy efficiency service providers, utilities, and building owners. This paper examines how local governments, utilities, and program implementers can replicate the success of DC and NYC. It gathers the findings from the Cities’ and their partners’ efforts to fully understand the datasets, overcome integration challenges, and apply the data to visual engagement, strategic outreach, evidence-based policymaking, and retrofit project identification and deployment. The paper goes beyond theoretical discussion by outlining practical application of data using specific examples from NYC and DC, summarizing challenges and findings, and highlighting next steps for other jurisdictions to learn from and build off the work done in those jurisdictions.

Cities↗

Establishment of Northwest Building Testbeds: Final Progress Report

This document provides a short summary of a project jointly funded by the DOE Building Technologies Program and the Northwest Energy Efficiency Alliance. The report the outcomes achieved in the jointly-funded project, describes major project activities, discusses future plans for the homes and data, and provides details on project costs and schedule performance.

Building Energy Efficiency↗

Energy impacts of nationwide window upgrades in commercial buildings

This report presents comprehensive estimates of the energy impacts of nationwide commercial building window upgrades in the United States, using a conservative approach. Windows play a substantial role in determining building energy use and occupant experience. Estimates point to commercial building windows impacting loads that represent more than 6 quads (approximately 6%) of annual primary energy use in the U.S. (Harris, 2022). Beyond heating and cooling loads, windows also have effects on lighting and occupant comfort. The fastest route to improving the energy efficiency of windows in U.S. buildings is upgrading or replacing windows in existing buildings. This is due to poor performance of windows in older existing buildings compared to most new construction, low levels of window replacement, and long window service life compared to energy-using building components. Nationwide window upgrades were considered using the following technologies: • Secondary glazing systems • Double pane (clear and tinted) • Triple pane (clear and tinted) • Electrochromic glazing Nationwide upgrades provide on the order of 4%–6% site energy savings in typical buildings, or up to 26% in buildings with the highest savings potential. Electrochromic windows, with their ability to adapt dynamically to environmental conditions, can provide additional benefits, ranging from median savings of 7.2% in buildings with window to wall ratio (WWR) greater than 10% and up to 28% for some buildings. Savings increase substantially for buildings with higher WWR. This study’s approach focused on isolating the direct energy benefits from improvement in window performance, and does not take into account the following additional benefits from window retrofits, which are likely to be substantial: • Managing peak demand and enabling HVAC equipment downsizing. • Energy savings from customizing upgrades to building type and climate. • Energy savings and comfort improvements resulting from post-retrofit reductions in air leakage. • Non-energy benefits, such as occupant comfort and resilience during extreme weather.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Byggmeister Test Home: Analysis and Initial Results of Cold Climate Wood-Framed Home Retrofit

The Building Science Corporation seeks to further the energy efficiency market for retrofit projects in the New England area by supporting projects that are based on solid building science fundamentals and verified implementation. The Building Science Corporation has been working with Byggmeister, a partner on its Building America Program team, on retrofit projects. Byggmeister is a Boston-area design-build firm that specializes in energy efficient retrofits and new construction. The DEAP (Duclos, Eldrenkamp and Panish) Energy Group, which is associated with Byggmeister, conducts energy analysis for projects during design and performs monitoring after completion. With the high exposure of energy efficiency and retrofit terminology currently being used in the general media, it is important to have evidence that measures being proposed will in fact benefit the homeowner through a combination of energy savings, improved durability, and occupant comfort. Concrete data from specific projects can close the gap between “hype” and reality. This technical report describes a deep energy retrofit project for a two-family wood framed home located in Belmont, Massachusetts. Built in the 1920s, this home is referred to in this report as the “Belmont Two-Family.” The report examines the retrofit measures for the enclosure and mechanical systems and the decision making that took place during project planning. Because the retrofit project is complete, projected and actual energy use data are compared for the 5 months immediately following the retrofit. Occupant reactions and experiences are also described. The retrofit measures implemented for the Belmont Two-Family resulted in a home with airtightness of 0.93 air changes per hour at 50 pascal test pressure, a Home Energy Rating System index of 44 (excluding photovoltaics), and initial energy use significantly less than the energy models projected. The home is on track to meet the Thousand Home Challenge. In these ways, the project meets or exceeds the energy goals established for the retrofit. Energy modeling tools were found to be useful during the planning stage for investigating the relative cost effectiveness of retrofit measures. They were less effective, however, in projecting actual energy use. Discrepancies between the results of different tools need to be better understood, and interactions among retrofit measures are not effectively handled by the energy modeling tools at this time. During the first few months after the retrofit, the homeowner had questions about the effective operation of the mechanical equipment. With the increased airtightness and R-values, the equipment needs to be operated differently to realize the potential energy savings. This information needs to be better understood and disseminated by everyone involved with retrofit projects. This technical report contributes to several basic areas of research. These include the combination of measures that is feasible, affordable, and acceptable to homeowners as well as expectations versus results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficient Opportunities During Remodeling or Renovation

Residential buildings go through many changes during their useful life, which is defined more by their care and maintenance, than age. Many homes that are a century old are still serviceable and desirable and even older homes that have been abandoned can be renovated. In contrast, many newly built homes are good candidates for energy efficiency retrofit measures before occupancy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline: Mitigation of Retrofit Risk Factors

The Alliance for Residential Building Innovation (ARBI) is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Services Sector: Workforce Education and Training Needs

This report provides a baseline assessment of the current state of energy efficiency-related education and training programs and analyzes training and education needs to support expected growth in the energy efficiency services workforce. In the last year, there has been a significant increase in funding for 'green job' training and workforce development (including energy efficiency), through the American Recovery and Reinvestment Act (ARRA). Key segments of the energy efficiency services sector (EESS) have experienced significant growth during the past several years, and this growth is projected to continue and accelerate over the next decade. In a companion study (Goldman et al. 2009), our research team estimated that the EESS will increase two- to four-fold by 2020, to 220,000 person-years of employment (PYE) (low-growth scenario) or up to 380,000 PYE (high-growth scenario), which may represent as many as 1.3 million individuals. In assessing energy efficiency workforce education and training needs, we focus on energy-efficiency services-related jobs that are required to improve the efficiency of residential and nonresidential buildings. Figure ES-1 shows the market value chain for the EESS, sub-sectors included in this study, as well as the types of market players and specific occupations. Our assessment does not include the manufacturing, wholesale, and retail distribution subsectors, or energy efficiency-focused operations and maintenance performed by facility managers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building America Case Study: Calculating Design Heating Loads for Superinsulated Buildings, Ithaca, New York; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Managing the On-Board Data Storage, Acknowledgment and Retransmission System for Spitzer

The Spitzer Space Telescope has a two-phase downlink system. Data are transmitted during one telecom session. Then commands are sent during the next session to delete those data that were received and to retransmit those data that were missed. We must build sequences that are as efficient as possible to make the best use of our finite supply of liquid helium, One way to improve efficiency is to use only the minimum time needed during telecom sessions to transmit the predicted volume of data. But, we must also not fill the onboard storage and must allow enough time margin to retransmit missed data. We describe tools and procedures that allow us to build observatory sequences that are single-fault tolerant in this regard and that allow us to recover quickly and safely from anomalies that affect the receipt or acknowledgment of data.

Spitzer↗